Вы находитесь на странице: 1из 1

Designation code for harmonized cables

according to DIN VDE 0281/DIN VDE 0282/DIN VDE 0292


Construction reference
Identifications of destignation
A H authorised national standards harmonized standards 100 V 300/300 V 300/500 V 450/750 V
H 05 V V5 F 25 G 0,75

Nominal voltage U
01 03 05 07

Insulation material
B G N2 R S V V2 V3 V4 Z C Q4 T T6

(EPR) Ethylene-propylene-rubber (EVA) Ethylene-Vinylacetat-Copolymer (CR) Chloroprene rubber for welding cables (NR a./o. SR) Natural a./o. synthetic rubber (SiR) Silicone rubber (PVC) Polyvinyl chloride (PVC) Polyvinyl chloride heat-resistant (PVC) Polyvinyl chloride low-temperature (PVC) Polyvinyl chloride cross-linked (PE) Polyethylene cross-linked Screen (PA) Additional polyimide core jacket Additional textile braiding over laid-up cores Additional textile braiding over individual cores (EPR) Ethylene-propylene rubber Glass fibre braid (CR) Chloroprene rubber (CR) Chloroprene rubber for welding cables (CR) Chloroprene rubber heat-resistant (PUR) Polyurethane (NR a./o. SR) Natural- a./o. synthetic rubber Textile braid Textile braid with flame retardant compound (PVC) Polyvinyl chloride (PVC) Polyvinyl chloride heat-resistant (PVC) Polyvinyl chloride low-temperature (PVC) Polyvinyl chloride cross-linked (PVC) Polyvinyl chloride oil resistant Stress-relieving elements (support wire) Centre core (no supporting element) Telecommunications cores integrated in power cables Flat, separable cable (twin cable) Flat, non-separable cable (two-core sheathed cable) Flat, non-separable cable (multi- and multiple sheathed cable) Two-layer insulating jacket Spiral cables Finely stranded, for welding cables (very) finely stranded, for welding cables Finely stranded, for cables for fixed installation (Very) finely stranded, for flexible cables Finely stranded, for cables for fixed installation Multiple-wire, round, class 2 Single-wire, round, class 1 Tinsel wire, DIN 47104

Structural elements

Sheath/jacket material
B J N N2 N4 Q R T T2 V V2 V3 V4 V5

Special structural features


D3 D5 FM H H2 H6 H7 H8 D E F H K R U Y

Conductor type

Number of cores Earth core


G X With earth core Without earth core

Conductor nominal cross section in mm2


Examples: H07V-U 2,5 black (according to DIN VDE 0281) Harmonized PVC-insulated single-core sheathed cable, 2,5 mm2 single-core, nominal voltage 750 V H07RN-F 3G 1,5 (according to DIN VDE 0282) Harmonized rubber-sheathed-cable for medium tensile loads, three-core 1,5 mm2, finely stranded, green-yellow earth core, nominal voltage 750 V