Gas Turbine Efficiency www.MeeFog.com/Gas_Turbine Improve Gas Turbine Output Download Our Whitepaper Today! Stack Analyzers www.ThermoScientific.com/air Comprehensive Compliance Systems Review Product Overviews Online CO2 Removal www.moleculargate.com CO2 Removal made easy with the Molecular Gate adsorption system Gas/Oil/Water Separation www.kirkprocess.com Separator internals and designs to maximise performance & capacity

FOLLOW ME

Enter your email address:

Vent and flare stack are used dispose waste gas in safe and enviroment friendly manner. Flare stack is probably preferred as compare to vent stack if the release fluid contain HC from environmental point of view e.g. impact to greenhouse effect for 1 mole of C1 is about 20 times of 1 mole of CO2. However, flare stack may be costly. For a vent stack, at least 3 main criteria shall be met : i) Toxic / flammable component well dispersed and meeting health and safe level during Normal operation (Nor. Op.) and emergency situation (Emer. Op.). very much subject to components / species in vent gas. Local regulations will probably indicate the limits of various components. In additional, Material Safety Datasheet (MSDS) will probably indicate the limits. PHAST, FRED, etc can be used for dispersion study. ii) Radiation due to ignition of lightning (Emer. Op.). In the event, vent gas is HC and potentially ignited by lightning, radiation study shall be conducted to ensure radiation at the receptor (human) point is meeting criteria e.g. 6.31 kW/m2. In addition to the radiation level, the temperature of receptor (equipment) shall not damage the equipment. FLARESIM, FRED, etc can be used for radiation study. iii) Noise level at receptor meeting noise criteria during Normal operation (Nor. Op.) and emergency situation (Emer. Op.). Noise level at receptor (human) is meeting criteria e.g. 115 dBA with background noise. Keeping in mind, some plant owner may impose more stringent requirement i.e. 90 dBA @ receptor (human). FLARESIM, FRED, etc can be used for noise study. If some spill over control PCV tie to vent header and release continuously into vent stack, fluid exit temperature may be a concern in some environment sensitive area.

SUPPORT This Site

1 of 3

27/04/2011 14:01

http://webwormcpt.blogspot.com/2007/07/factors-and-criteria-for-vent-stack.html

API 521 has recommended Mach = 0.5 and this value is probably a good start for vent diameter determination. Vent stack height will subject to above criteria, location of vent stack, plant layout, wind speed, wind direction, etc. Modeling vent stack with inclusion of vent diameter and height using software as mentioned will be conducted in order to ensure meeting all criteria as mentioned earlier.

WebWorm Continue receive FREE stuff & Update.......Subscribe by Email OR RSS Any comments / advices ?..........Drop it in comment field (below) or sent a private email to me... Labels: Environment, Flare, Stack, Vent

Process engineer jobs

PROCESS ENGINEER
WESTINDO ESA PERKASA, PT - Cibinong
located at Cibinong, Bogor is looking for : PROCESS ENGINEER Requirements : S1 degree with background... Jobs Keywords: PROCESS ENGINEER Personal Notes... JobsDB Indonesia more jobs

Jobs by Indeed

posted by Webworm, 4:45 AM

Post a Comment
Let us know your opinion !!! You can use some HTML tags, such as <b>, <i>, <a>
Recommended Jobs Chemical Engineer Cikarang - PT Priuk Perkasa Abadi Process Improvement Specialist Jakarta - EONCHEMICALS PUTRA, PT Process Engineer Jakarta - PT Bidar Timur Sales Engineer for Process Jakarta - PT. Yabestindo Mitra Utama Process Engineer (Code : PEG) South Jakarta - CITRA NUSANTARA GEMILANG

www.indeed.com

2 of 3

27/04/2011 14:01

http://webwormcpt.blogspot.com/2007/07/factors-and-criteria-for-vent-stack.html

Subscribe to Post Comments [Atom]

Create a Link

<< Home

2008-2010 Chemical & Process Technology | Design by Webworm

3 of 3

27/04/2011 14:01

Вам также может понравиться