Вы находитесь на странице: 1из 11

Carnhill Transformers Design Guide - Issue 1

Tel/Fax +44 (0)161 654 0748 Email: service@audiomaintenance.com

VTB 1148 - High Level Output Transformer


[for Professional Audio Applications]

A high performance, no compromise, professional audio signal transformer primarily intended for high level balanced line output applications

Audio Maintenance Limited, Unit 10 Hanson Close Industrial Estate, Middleton, Manchester. M24 United Kingdom.

Tel/Fax +44 (0)161 654 0748 Email: service@audiomaintenance.com

VTB 1847 - High Level Output Transformer


[for Professional Audio Applications]

A high performance, no compromise, professional audio signal transformer primarily intended for high level balanced line output applications

Audio Maintenance Limited, Unit 10 Hanson Close Industrial Estate, Middleton, Manchester. M24 United Kingdom.

Tel/Fax +44 (0)161 654 0748 Email: service@audiomaintenance.com

VTB 9045 - Low Level Audio Signal Transformer


[for Professional Audio Applications]

A high performance, no compromise, professional audio signal transformer primarily intended for low level microphone input applications

Audio Maintenance Limited, Unit 10 Hanson Close Industrial Estate, Middleton, Manchester. M24 United Kingdom.

Tel/Fax +44 (0)161 654 0748 Email: service@audiomaintenance.com

VTB 9046 - High Level Audio Signal Transformer


[for Professional Audio Applications]

A high performance, no compromise, professional audio signal transformer primarily intended for low level microphone input applications

Audio Maintenance Limited, Unit 10 Hanson Close Industrial Estate, Middleton, Manchester. M24 United Kingdom.

Tel/Fax +44 (0)161 654 0748 Email: service@audiomaintenance.com

VTB 9049 - High Level Output Transformer


[for Professional Audio Applications]

A high performance, no compromise, professional audio signal transformer primarily intended for high level balanced line output applications

Audio Maintenance Limited, Unit 10 Hanson Close Industrial Estate, Middleton, Manchester. M24 United Kingdom.

Tel/Fax +44 (0)161 654 0748

VTB 9056 - High Level Output Transformer


[for Professional Audio Applications]

A high performance, no compromise, professional audio signal transformer primarily intended for high level balanced line output applications

Audio Maintenance Limited, Unit 10 Hanson Close Industrial Estate, Middleton, Manchester. M24 United Kingdom.

Tel/Fax +44 (0)161 654 0748 Email: service@audiomaintenance.com

VTB 9057 - High Level Output Transformer


[for Professional Audio Applications]

A high performance, no compromise, professional audio signal transformer primarily intended for high level balanced line output applications

Audio Maintenance Limited, Unit 10 Hanson Close Industrial Estate, Middleton, Manchester. M24 United Kingdom.

VTB9043
S G A B

S - Coil Start A: 1.3H B: 3.0H

Inductance values shownare measured with respect to coil start (S) at 1kHz Inductance values are +/- 10%

D: 7.0H E: 10.0H G - Earth

Underside view

VTB9044

S - Coil Start
G S B

B: 50mH C: 80mH

Inductance values shownare measured with respect to coil start (S) at 1kHz Inductance values are +/- 10%

D: 100mH E: 160mH F: 200mH G - Earth

Underside view

VTB9050
H G S A B

S - Coil Start A: 100mH B: 160mH

Inductance values shownare measured with respect to coil start (S) at 1kHz Inductance values are +/- 10%

F E D

D: 220mH E: 450mH F: 1.0H H: 2.0H G - Earth

Underside view

VTB9054

S - Coil Start
S A B

A: 67mH B: 95mH

Inductance values shownare measured with respect to coil start (S) at 1kHz Inductance values are +/- 10%

C: 129mH D: 193mH E: 287mH

Underside view

VTB9055

S - Coil Start
S A B

A: 450mH B: 670mH

Inductance values shownare measured with respect to coil start (S) at 1kHz Inductance values are +/- 10%

C: 950mH D: 1.3H E: 1.93H

Underside view

VTB9047

S - Coil Start
C B A Coil start is indicated by dot on upper side

A: 1.4H B: 2.1H C: 3.5H

Inductance values shownare measured with respect to coil start (S) at 1kHz Inductance values are +/- 10%

Underside view

D: 5.1H

VTB9048

S - Coil Start
C B A Coil start is indicated by dot on upper side

A: 200mH B: 300mH C: 500mH

Inductance values shownare measured with respect to coil start (S) at 1kHz Inductance values are +/- 10%

Underside view

D: 760mH

Вам также может понравиться