Name of shift incharge :TMT size being rolled:Furnace Temperature (when mill stopped for heat delay Soaking zone:Heating zone:Total No. of coal buckets charged :Roughing Mill Condition of guides:- OK or needs replacement Boxes:- OK or needs replacement Plates :- OK or needs replacement Condition of all cooling headers :- Ok or need replacement Gap in the passes:- OK or needed to be checked again also clear the gap pass measurment (________________) Section sizes measured :- OK or not accurate (current section weight:-____________) Internediate Mill Condition of entry and delivery guides & roll /pass gaps. Inter 1 :-
Inter 2 :Inter 3 :Inter 4 :Level of repeaters :Pinch roll condition :Roll cooling :-
Roll cooling headers :Delivery after shear:Weight of tmt:Weight of end cutting ( front & back)
Shift incharge ka naam:TMT size jo rolling kiya ja rha hai:Bhatthi ka tapman ( Jab mill band hui ho tapman ky karanwash) Bhatthi Thermax Time Temperature Time Temperature
Kitna bucket koyla charged hua :Roughing Mill Guides ki esthiti:Boxes ki esthiti:OK hai ya badlna chahye :_ OK hai ya badlna chahye :_ OK hai ya badlna chahye :_ OK hai ya badlna chahye :_
Plates esthiti jo roughing stand1 ka pass ha:Sabhi roll cooling headers ki esthiti:Pass gap kitna ha:Section sizes ko mapa gaya ya nahi:Roughing 2 oval(time)
3 Square(time)
Remark
Sabhi entry or delivery guides ki esthiti:Repeaters ky level check kiya gaya ya nahi :Pinch roll check kiya gaya ya nahi :Roll cooling system check kiya gaya ya nhi :-
1 Pass no:oval(time)
2 TMT/Round(time)
Remarks
Sabhi entry or delivery guides ki esthiti:Control room ma kitni martaba amper ki janch(enqury) ki gaye:Roll cooling headers ki esthiti kya ha:-
Thnadha mall ky samy(time) pulpit ma kya tapman tha or bhathi ky soaking zone ma kya tapman tha:-
Signature of foreman
Signature of HOD
Shift incharge ka naam:TMT size jo rolling kiya ja rha hai:Bhatthi ka tapman ( Jab mill band hui ho tapman ky karanwash) Bhatthi Thermax Time Temperature Time Temperature
Kitna bucket koyla charged hua :Roughing Mill Guides ki esthiti:Boxes ki esthiti:OK hai ya badlna chahye :_ OK hai ya badlna chahye :_ OK hai ya badlna chahye :_ OK hai ya badlna chahye :_
Plates esthiti jo roughing stand1 ka pass ha:Sabhi roll cooling headers ki esthiti:Pass gap kitna ha:Section sizes ko mapa gaya ya nahi:-
Roughing 1 Pass no:- Diamond(time) Square(time) 2 oval(time) Square(time) oval(time) 3 Square(time) Remark
Sabhi entry or delivery guides ki esthiti:Repeaters ky level check kiya gaya ya nahi :-
1 Pass no:oval(time)
2 TMT/Round(time)
5 oval(time)
6 TMT/round(time)
Remarks
Thnadha mall ky samy(time) pulpit ma kya tapman tha or bhathi ky soaking zone ma kya tapman tha:-
Signature of foreman
Signature of HOD
Shift incharge ka naam:TMT size jo rolling kiya ja rha hai:Bhatthi ka tapman ( Jab mill band hui ho tapman ky karanwash) Bhatthi Temperature Time
Time
Thermax Temperature
Roughing Mill Guides ki esthiti:Boxes ki esthiti:OK hai ya badlna chahye :_ OK hai ya badlna chahye :_ OK hai ya badlna chahye :_ OK hai ya badlna chahye :_
Plates esthiti jo roughing stand1 ka pass ha:Sabhi roll cooling headers ki esthiti:Pass gap kitna ha:Section sizes ko mapa gaya ya nahi:-
Pass no:-
Diamond
1 Square
oval
Square
Roughing 2 oval
3 Square
Time
Remark
Time
Remark
oval
oval
Sabhi entry or delivery guides ki esthiti:Repeaters ky level check kiya gaya ya nahi :-
Roll cooling system check kiya gaya ya nhi :Continuous mill 4 TMT/round
1 Pass no:oval
2 TMT/Round
3 oval
5 oval
6 TMT/round
Time
Remarks
Control room ma kitni martaba amper ki janch(enqury) ki gaye:Roll cooling headers ki esthiti kya ha:-
HOD and Deepak ki koi madad(help) chahye(needed):Roll pass kab change kiya gaya and kitna production us pass se hua Production kitna hua
Time
HOD ka koi sujhaoo or koi comment:Signature of foreman Signature of HOD Signature of shift incharge