Вы находитесь на странице: 1из 67

INSTRUCTION MANUAL

SELECTIVE LEVELMETER
MODELS 3121B, 3126B, 3132
WCCW
RYCOM INSTRUMENTS
R a i 1 ~ a y Communications
f
Inc.
9351 East 59th Street
Raytown
f
Missouri
INSTRUCTION MANUAL
SELECTIVE LEVELMETER
MODELS 3121B
f
3126B
f
3132
STANDARD INSTRUMENTS
MODEL
SELECTIVITY
(MEASURE)
COUNTER OUTPUT
MODULE
INSTRUMENT
SERIAL NO.
3121B 100 Hz YES
3121B 250 Hz NO
3126B 250 Hz NO
3132 100 Hz YES
3132 250 Hz NO
(Manual No. 3121-341)
3-72
WCCW
CERTIFICATION
The RYCOM Instruments Company certifies that this instrument was thoroughly
tested and inspected and found to meet its published specifications when it
was shipped from the factory.
WARRANTY AND ASSISTANCE
All RYCOM Instruments Products are warranted against defects in material and
workmanship. This warranty applies for one year from the date of delivery,
or, in the case of certain major components listed below for the specified
period we will repair or replace products that prove to be defective during
the warranty period. No other warranty is expressed or implied. We are not
liable for consequential damages.
Exceptions in our products using dry batteries or Ni-Cad batteries the above
warranty applies to the equipment only. Ni-Cad batteries are Bubject to
original manufacturers inspection.
Where it is necessary to return the instrument to the factory, furnish in
formation to the nature of trouble encountered. Ship prepaid to:
RYCOM INSTRUMENTS
9351 East 59th Street
Raytown, Missouri 64133
Attention: Service Department
---,
3-72
LIST OF EFFECTIVE PAGES
Total Number of Pages in This Publication is 70
Page No. Issue Page No. Issue
Title
Warranty
A
B Blank
i thru iv
1 thru 3
4 Blank
5 thru 51
52 Blank
53
Original
Original
Original
Original
Original
Original
Original
Original
Original
Original
54 Blank
55
56 Blank
57
58 Blank
59
60 Blank
61
62 Blank
Original
Original
Original
Original
Original
Original
Original
Original
Original
*An asterisk indicates pages changed, added, or deleted by the latest revision.
Effective Pages
3-72 Page AlB
TABLE OF CONTENTS
CHAPTER I GENERAL
1. Scope. 1
2. Description 1
CHAPTER II OPZRATION
1. Preparation. 5
2. Operating Controls and Indicators. 5
3. Battery 7
4. Calibration. 7
5. Line Measurements, Models 3l2lB (Unbalanced) and 3132 8
6. Model 3l2lB Line Measurements--Balanced. 8
7. INPUT SELECTOR Setting and Meter Correction, Models 312lB and 3132. 9
8. Model 3l26B Line Measurements--INPUT Jacks. 10
9. Model 3126B Line Measurements--20-Pin Connector. 10
10. INPUT SELECTOR Setting and Meter Correction, Model 3l26B 11
11. Monitoring 12
12. Counter Output 12
CHAPTER III THEORY OF OPERATION
1. General 13
2. Input Module AI. 14
3. Emitter-Follower and Calibrate Oscillator Module A2. 14
4. Lowpass Filter FL3. 14
5. Oscillator-Modulator Module A3. 14
6. I-f Amplifier Module A4 . 14
7. Demodulator Module AS. 15
8. Audio Amplifier Module AS 15
9. Regulator Module AS 16
10. Ac Power Supply and Charger Module A6 16
11. Counter Output Module A7. 16
CHAPTER IV MAINTENANCE
1. Introduction. 17
2. Test Equipment 17
3. Trouble Shooting 18
4. Alignment.
24
CHAPTER V PARTS LIST
1. How to Order Parts.
29
2. List of Manufacturers.
29
3-72
i
LIST OF TABLES
Table
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Description
Specifications .
Operating Controls and Indicators.
Models 3l2lB and 3132 Calibration.
Models 312lB and 3132 INPUT SELECTOR Setting and Meter Correction
Model 3l26B INPUT SELECTOR Setting and Meter Correction
Test Equipment
Module Isolation
Regulator Module A5 Trouble Shooting.
Power Supply and Charging Circuit Module A6
Input Module Al Trouble Shooting .
Emitter-Follower Module A2 Trouble Shooting
Trouble Shooting.
Calibrate Oscillator Module A2 Trouble Shooting
Lowpass Filter FL3 Trouble Shooting .
Local Oscillator Module A3 Trouble Shooting
I-f Amplifier Module A4 Trouble Shooting
Reinsertion Oscillator Module A5 Trouble Shooting
Audio Amplifier Module AS Trouble Shooting.
Transistor Voltage Chart. . '.
Integrated Circuit Voltages.
LIST OF ILLUSTRATIONS
Figure
~
Description
1
2
3
4
5
Models 3l2lB and 3l26B Selective Levelmeters
Model 3132 Selective Levelmeter
Test Setup for Module Isolation
Test Setup for Level Calibration
Test Setup for Frequency Alignment
.
6 Module A2.
7 Module A3.
8 Module A4.
9 Hodule A5.
10 Module A7.
11 Block Diagram
l2A 3l2lB Input, Schematic
l2B 3126B Input, Schematic
l2C 3132 Input, Schematic.
12 Selective Levelmeter,
13 Counter Output Hodule,
Basic Schematic
Schematic .
Page
2
5
8
9
11
17
18
19
20
20
21
21
21
22
22
22
23
23
24
Page
iii
iv
18
24
27
48
48
49
50
50
51
53
55
57
59
61
ii 3-72
-
1


....
1\5 v
A(
Sl:.J,> N<)
IlljDIO LEVEl
I Nt' 'f : "',
PQWH
HeAPS! I
HJEC lOR
Figure 1
Models 3l21B and 3l26B Selective Levelrneters
3-72
iii
NO
1 \1
'C
AU01('I I FVH
POW[I<:
'tEAOSfT
r-
! ,..I -Jq 0) ! I
-AIJ Ql .---,.........lrr.... r- I tfl

tNPUl
"""
Figure 2
Model 3132 Selective Levelmeter
c--..
iv 3-72
L
CHAPTER I
GENERAL
SCOPE.
This manual describes the following RYCOM instruments:
Model 3l2lB Selective Levelmeter
Model 3l26B Selective Levelmeter
Model 3132 Selective Levelmeter
2. DESCRIPTION.
All the instruments are intended for general use where it is desired to measure
the level of individual or narrow bands of frequencies. Each can be operated
with its internal battery, or from 115 volts, 50 to 400 Hz, which is also used
to charge the battery.
Table 1 lists the specifications and figures 1 and 2 show the instruments.
The instruments are all fully transistorized. Each measures voltage from 7.75
microvolts to 10 volts (-100 dBm to +22 dBm) in the frequency range 1 to 1500
kilohertz. Excepting Model 3l26B (250 Hz only), each instrument has a 100- or
2s0-Hz bandwidth filter that makes it particularly useful for analyzing closely
spaced signals, complex waveforms, determining carrier system levels, and check
ing amplitude modulation percentages. Included is a 2.s-kHz bandwidth filter
that has a O.s dB ripple factor. Special features include an internal oscill
ator for calibration, a speaker, a headphone jack for aural monitoring, and a
built-in battery charger.
A compact metal cabinet 8 inches high, 12 inches wide, and 9 inches deep houses
the instrument. Weight, including the battery, is 15 -pounds. The front panel
contains all the operating controls and is protected by a metal cover that snaps
in place. The POWER switch must be set to the OFF position before the cover can
be installed, thereby preventing the possibility of battery discharge while the
instrument is not in use.
Most of the circuitry is laid out on printed circuit boards and assembled into
six separate modules. Extensive shielding is provided for modules and compon
ents to prevent interaction between circuits.
The POWER switch is used to select either 115 volts, 50-400 Hz, or an internal
nickel-cadmium battery as the power source. The battery will operate the instru
ment approximately 35 hours without recharging. The instrument will operate on
the lIS-volt ac line source with or without the battery and regardless of battery
condition. A polarized three-pin male connector, on the right side of the front
panel, provides access for battery charging and operation from the ItS-volt ac
source. The instrument may be operated while the battery is charging.
3-72 1
Table 1. Specifications
NOTE: Except where indicated, specifications apply to all instruments.
CHARACTERISTIC
FREQUENCY RANGE 1 to 1500
Band A:
Band B:
Band C:
SPECIFICATION
kHz (3 bands)
1 to 310 kHz
300 to 710 kHz
690 to 1500 kHz
SELECT IVITY
FREQUENCY ACCURACY
MEASUREMENT ACCURACY
SPURIOUS RESPONSE AND INTERMODULATION
PRODUCTS
INTERNAL CALIBRATION SOURCE
INTERMEDIATE FREQUENCY
TYPES OF DEMODULATION
TEMPERATURE RANGE
POWER SUPPLY
CURRENT DRAIN
BATTERY LIFE
OVERALL DIMENSIONS
WEIGHT
INPUT LEVEL
100 Hz nominal at 3 dB down
400 Hz maximum at 60 dB down
or
250 Hz nominal at 3 dB down
1100 Hz maximum at 60 dB down
and
2500 Hz nominal at 3 dB down
10,000 Hz maximum at 60 dB down
Dial: Band A l kHz
Band B 2 kHz
Band C 3 kHz
Counter: All bands 20 Hz
l dB
Greater than 55 db down
250-kHz crystal oscillator
2215 kHz
AM, LSB, and USB
-lOD C to +50
D
C
l2-volt nickel-cadmium battery or lIS
volts, 50 to 400 Hz, for ac operation
and for charging battery
35 ma average
35 hours without recharging
8 in. high x 12 in. wide x 9 in. deep
15 Ib
-100 to +22 dBm (7.75 uV to 10 V)
2 3-72
CHAPTER I
GrnEAAL
1. SCOPE.
This manual describes the following RYCQM instruments:
Model 3l2lB Selective Levelmeter
Model 3126B Selective Levelmeter
Model 3132 Selective Levelmeter
2. DESCRIPTION.
All the instruments are intended for general use where it is desired to measure
the level of individual or narrow bands of frequencies. Each can be operated
with its internal battery, or from 115 volts, 50 to 400 Hz, which is also used
to charge the battery.
Table 1 lists the specifications and figures land 2 show the instruments.
The instruments are all fully transistorized. Each measures voltage from 7.75
microvolts to 10 volts (-100 dBm to +22 dBm) in the frequency range 1 to 1500
kilohertz. Excepting Model 3126B (250 Hz only), each instrument has a 100 or
2s0-Hz bandwidth filter that makes it particularly useful for analyzing closely
spaced signals, complex waveforms, determining carrier system levels, and check
ing amplitude modulation percentages. Included is a 2.s-kHz bandwidth filter
that has a O.S dB ripple factor. Special features include an internal oscill
ator for calibration, a speaker, a headphone jack for aural monitoring, and a
built-in battery charger.
A compact metal cabinet 8 inches high, 12 inches wide, and 9 inches deep houses
the instrument. Weight, including the battery, is 15 'pounds. The front panel
contains all the operating controls and is protected by a metal cover that snaps
in place. The POWER switch must be set to the OFF position before the cover can
be installed, thereby preventing the possibility of battery discharge while the
instrument is not in use.
Most of the circuitry is laid out on printed circuit boards and assembled into
six separate modules. Extensive shielding is provided for modules and compon
ents to prevent interaction between circuits.
The POWER switch is used to select either 115 volts, 50-400 Hz, or an internal
nickel-cadmium battery as the power source. The battery will operate the instru
ment approximately 35 hours without recharging. The instrument will operate on
the lls-volt ac line source with or without the battery and regardless of battery
condition. A polarized three-pin male connector, on the right side of the front
panel, provides access for battery charging and operation from the lIS-volt ac
source. The instrument may be operated while the battery is charging.
3-72 1
Table 1. Specifications (Cont)
CHARACTERISTIC
INPUT lMPEDANCE
Model 3l2lB
Model 3l26B
Model 3132
METER INDICATION
Model 3l2lB
Model 3l26B
Model 3132
SPECIFICATION
75-, 135-, 600-ohm terminating or
bridge (SK ohms nominal)--unbalanced
when operating from 115 Vac
135 or 600-ohm bridge--ba1anced or
unbalanced
135 or 600-ohm terminating--ba1anced
or unbalanced
75, 135, 600 ohms or bridge-
unbalanced
75, 135, 600 ohms or bridge--balanced
DBm on 75-, 135-, and 600-ohm line;
volts when calibrated for 600 ohms
DBm on 135 and 600-ohm line; volts
with INPUT SELECTOR switch in 600
ohm position
DBm on 75-, 135-, and 600-ohm line;
volts when calibrated for 600 ohms
3-72 3/4
CHAPTER II
OPERATION
1. PREPARATION.
The instrument has been thoroughly inspected at the factory and is covered by
Warranty. However; before using the instrument. you should inspect it for
shipping damage. Report any damage to the carrier and to RYCOM Instruments,
Inc.
2. OPERAT ING CONTROLS AND IND ICATORS.
Table 2 lists and describes the instrument controls and indicators.
Table 2. Operating Controls and Indicators
PANEL MARKING
BAND SELECTOR
TUNING
SELECTIVITY
ATTENTUATOR
CAL LEVEL
MONITOR
AUDIO LEVEL
HEADSET
INPUT
DESCRIPT ION
3-position rotary switch
Driven tuning mechanism,
2-speed
2-position rotary switch
ll-position rotary switch
Potentiometer
3-position rotary switch
Potentiometer
Head phone j ac k
Binding posts (also 20-pin
connector on Model 3126B)
FUNCTION
Selects frequency band A,
B, or C
Tunes instrument to fre
quency indicated on dial
face
Selects bandwidth 250 Hz
(100 HZ) or 2.5 kHz
Controls sensitivity in
la-dB steps up to 100 dB
Adjusts overall gain during
calibration
Selects AM or single side
band (LSB, USB) demodula
tion
Adjusts audio level for
headset
Provision for audio moni
toring
Signal input for measure
ments
3-72 5
------
Table 2. Operating Controls and Indicators (Cont)
PANEL MARKING
POWER
US VAC
No marking
COUNTER
(not on all instru
ments)
INPUT SELECTOR
INPUT SELECTOR
No marking
INPUT SELECTOR
DESCRIPTION
4-position rotary switch,
spring loaded in BAT. TEST
position
Polarized connector
1/4-in. black knob on
FREQUENCY dial bezel
BNC connector
MODEL 3l21B ONLY
5-position rotary switch
MODEL 3l26B ONLY
Ii-position rotary switch
Shorting link on lower two
INPUT binding posts
MODEL 3132 ONLY
9-position rotary switch
FUNCTION
Connects power supply to
ac line, battery, or
battery test circuit
Provision for connection
to 115-Vac line
Rotates cursor 5 for
frequency correction
Provision for connection
to electronic frequency
counter
1. Selects input termina
tions of 75, 135, 600
ohms, or BRIDGE
2. Selects CAL position for
calibration
1. Selects input termina
tions of 135- or 600
ohm BRG, 135- or 600
ohm TERM for binding
posts, and has three IN
and OUT positions for 20
pin connector
2. Selects CAL position for
operational calibration
-
1. Provides ground for un
balanced measurements
when connected
2. Removes ground for bal
anced measurements when
disconnected
1. Selects input termina
tions of BRIDGE, 600-,
135-, or 7S-ohm input;
BALANCED or UNBALANCED
2. Selects CAL position for
operational calibration
3-72 6
3. BATTERY.
The battery will provide up to 35 hours of operation between charges. A com
pletely discharged battery will recharge in 24 hours or less. A routine re
charging schedule should be established, dependent upon instrument use, but
the battery should be charged at least ~ per month. (With continuous ac
operation, battery charging is unnecessary.)
a. To charge battery, connect instrument to primary power source (115 Vac)
and set POWER switch to BAT.
b. To test condition of battery while it is delivering full load current,
set POWER switch to BAT. TEST. Battery is fully charged when the meter
indicates 0 O.S dBm.
4. CALIBRATION.
This procedure checks the main tuning dial and overall sensitivity. Steps not
prefixed with a model number apply to all instruments. Perform all steps in
the sequence given, omitting steps that are prefixed with model numbers other
than that of your instrument.
a. Set INPUT SELECTOR switch to CAL.
b. Set ATTENUATOR switch to CAL -30 DB.
c. Set SELECTIVITY switch to 250 (100) Hz.
d. Set BAND SELECTOR switch to A.
e. Adjust TUNING control for maximum indication on meter. FREQUENCY dial will
indicate approximately 250 kHz.
f. Set red cursor on FREQUENCY dial to 250 CAL.
g. Models 3121B and 3132. To calibrate for dBm (600 ohms) and voltage,
adjust CAL LEVEL control for dBm indication on meter.
h. Models 3121B and 3132. To calibrate for dBm (135 ohms), perform steps ~
through i except s t e p ~ . (For s t e p ~ , set ATTENUATOR switch to -20 DB.)
Then adjust CAL LEVEL control for -3.5 dBm indication on meter.
i. Models 3l21B and 3132. To calibrate for dBm (75 ohms), perform steps ~
through i except s t e p ~ . (For step ~ , set ATTENUATOR switch to -20 DB.)
Then adjust CAL LEVEL control for -1 dBm indication on meter.
j. Table 3 is a reference chart for calibration of Models 3l21B Bnd 3132.
3-72 7
--
Table 3. Models 3121B and 3132 Calibration
CALIBRATION
IMPEDANCE
ATTENUATOR
METER
INDICATION
600 ohms and volts CAL -30 DB
o dBm
135 ohms -20 DB -3.5 dBm (red)
75 ohms -20 DB -1.0 dBm (red)
k. Model 3126B. To calibrate, perform steps a through f and adjust CAL LEVEL
control for 0 dBm indication on meter. Th; meter is-now calibrated for
voltage and dBm (600 ohms) and dBm (135 ohms). See table 5. Red lines on
meter do not apply to Model 3126B.
1. A frequency check can be made by tuning the FREQUENCY dial through its
range. Meter indications should be observed at every 250-kHz point; e.g.)
500, 750, 1000, 1250, and 1500 kHz.
5. LINE MEASUREMENTS, MODELS 3121B (UNBALANCED) AND 3132.
(Model 3l21B unbalanced; Model 3132 unbalanced or balanced, depending upon
INPUT SELECTOR switch position.)
a. Connect the instrument INPUT to circuit being tested.
b. Calibrate the instrument for source or line impedance according to
paragraph 4.
c. Set INPUT SELECTOR switch to desired impedance. See paragraph 7.
d. Set BAND SELECTOR switch and adjust TUNING control to frequency of signal
to be measured.
e. Set ATTENUATOR switch sO meter indicates in upper 2/3 of scale.
f. Adjust TUNING control for maximum indication on meter.
g. Read meter indication. See table 4. To obtain the input signal level,
algebraically add the meter indication to the ATTENUATOR switch setting.
6. MODEL 3121B LINE MEASUREMENTS--BALANCED.
To make balanced line measurements, perform step ~ or ~ .
a. Place the instrument face up (resting on the four rubber feet) and remove
the ac line cord from the 115 VAC receptacle. set POWER switch to BAT.
position. This places approximately 100 picofarads of unbalance to ground
from the ground terminal of the instrument.
8 3-72
b. A balancing transformer, RYCOM Model 3061, can be used. This transformer
is optional and can be obtained from RYCOM. See instructions on trans
former for use.
After performing step ~ o r ~ , proceed with measurements described in paragraph
5.
7. INPUT SELECTOR SETTING AND METER CORRECTION, MODELS 3121B AND 3132.
a. INPUT SELECTOR on BRIDGE.
(1) Use this position to connect across a 75-, 135-, or 600-ohro line to
make clBm measurements when calibrated for the proper line impedance.
For greatest a c c u ~ a c y , apply the correction factors listed in table
4 for BRIDGE.
(2) Use this position to connect across any low-impedance line to make
voltage measurements. Calibrate for 600 ohms according to paragraph
4..
b. INPUT SELECTOR on 600 Ohms. Use this position to terminate a 600-ohm line
to make dBm (1 mW in 600 ohms) or voltage measurements. Calibrate for 600
ohms according to paragraph 4..
c. INPUT SELECTOR on 135 Ohms. Use this position to terminate a 135-ohm line
to make dBm (1 mW in 135 ohms) measurements. Calibrate for 135 ohms accord
ing to paragraph 4.h.
d. INPUT SELECTOR on 75 Ohms. Use this position to terminate a 75-ohm line
to make clBm (1 mW in 75 ohm ~ measurements. Calibrate for 135 ohms accord
ing to paragraph 4.1.
Table 4. Models 3121B and 3132 INPUT SELECTOR Setting and Meter Correction
INPUT
SELECTOR
CALIBRATION
IMPEDANCE
METER
INDICATION
SOURCE OR LINE
IMPEDANCE
METER CORRECT10
FACTOR
BRIDGE
(5000 ohms)
600 ohms
TERM
135 ohms
TERM
600 ohms
135 ohms
75 ohms
600 ohms
135 ohms
Volts and clBm
(600 ohms)
dBm (135 ohms)
dBm (75 ohms)
Volts and dBm
dBm
600 ohms
135 ohms
75 ohms
600 ohms
135 ohms
+0.5 dBm
+0.3 dBm
0
0
0
3-72 9
Table 4. Models 3121B and 3132 INPUT SELECTOR Setting and Meter Correction (Cont)
INPUT
SELECTOR
CALIBRATION
IMPEDANCE
METER
INDICATION
SOURCE OR LINE
IMPEDANCE
METER CORRECTION
FACTOR
75 ohms
TERM
75 ohms dBm 75 ohms a
e. Example: BRIDGE position calibrated for 600 ohms shows meter correction
factor of +0.5 dBm. Loading effects of the SODa-ohm voltmeter impedance
across 600 ohms gives a meter reading that is 0.5 dBm low due to loading.
Therefore, add +O.S dB to the meter reading for precise measurements.
f. The use of improper TERM positions is discouraged due to improper impedance
matching and large errors in the meter reading.
8. MODEL 3l26B LINE MEASUREMENTS--INPUT JACKS.
a. Connect instrument INPUT jacks to circuit to be tested. For unbalanced
lines, use shorting link. For balanced lines, disconnect shorting link.
b. Calibrate instrument according to paragraph 4.
c. Set INPUT SELECTOR switch to desired impedance.
d. Set BAND SELECTOR switch and adjust TUNING control to frequency of signal
to be measured.
e. Set ATTENUATOR switch so meter indicates in upper 2/3 of scale.
f. Adjust TUNING control for maximum indication on meter.
g. Read meter indication. See table 5. To obtain the input signal level,
algebraically add the meter indication to the ATTENUATOR switch setting.
9. MODEL 3l26B LINE MEASUREMENTS--20-PIN
The 20-pin INPUT connector is provided for bridging onto l35-ohm balanced
carrier lines of Western Electric N or ON carrier. To perform l35-ohm carrier
line measurements, proceed as follows:
a. Patch instrument to circuit to be tested.
b. Calibrate instrument according to paragraph 4.
c. Set INPUT SELECTOR switch as required for circuit to be measured.
d. Set BAND SELECTOR switch and adjust TUNING control to frequency of signal
to be measured.
e. Set switch so meter indicates in upper 2/3 of scale.
10 3-72
f. Adjust TUNING control for maximum indication on meter.
g. Read meter indication in dBm. To obtain the input signal level, algebrai
cally add meter indication to ATTENUATOR switch setting.
10. INPUT SELECTOR SETTING AND METER CORRECTION, MODEL 3l26B.
The calibration given in paragraph 4.k serves for measurements on both 135
and 600-ohm lines.
a. INPUT SELECTOR on 135 Ohms BRG. Use this position to connect across a 135
ohm line to make dBm (1 mW in 135 ohms) measurements. For precise measure
ments, see meter correction factor in table 5.
b. INPUT SELECTOR on 600 Ohms BRG. Use this position to connect across a 600
ohm line to make dBm (1 mW in 600 ohms) or to connect across ~ n y low
impedance line to make voltage measurements. For precise measurements,
see meter correction factor in table 5.
c. INPUT SELECTOR on 135 Ohms TERM. Use this position to terminate a l35-ohm
line to make dBm (1 mW in 135 ohms) measurements.
d. INPUT SELECTOR on 600 Ohms TERM. Use this position to terminate a 600-ohm
line to make dBm (1 mW in 600 ohms) or voltage measurements.
e. INPUT SELECTOR on IN or OUT Positions. Use these positions to connect
across the l35-ohm balanced lines of Western Electric N or ON carrier to
make dBm (1 mW in 135 ohms) measurements. (See paragraph 9.)
Table 5. Model 3l26B INPUT SELECTOR Setting and Meter Correction
INPUT
SELECTOR
135 ohms
TERM
135 ohms
BRG
600 ohms
BRG
600 ohms
TERM
CALIBRATION
IMPEDANCE
*600 ohms
*600 ohms
*600 ohms
*600 ohms
METER INDICATION
DBm from l35-ohm
source
DBm from l35-ohm
source
Volts from any low
impedance source and
dBm from 600-ohm source
Volts or dBm from 600
ohm source
*This is equivalent to 600 ohms calibration impedance
but not selectable in Model 3l26B. The example given
7 . ~ applies to Model 3l26B also.
METER CORRECTION
FACTOR
o
+0.3 dBm
+0.5 dBm
o
in other units
in paragraph
3-72
11
11. MONITORING.
Provision is made for monitoring audio signals that may be present on line
signals under measurement. To monitor signals, set SELECTIVITY switch to
2.5 KHz, set MONITOR switch to desired position (AM, LSB, or USB), and adjust
AUDIO LEVEL control to the desired audio level.
12. COUNTER OUTPUT.
The counter is normally supplied with 100-Hz instruments.
a. Using a short length of coaxial cable, connect the instrument COUNTER out
put jack to the input of a frequency counter with the following minimum
characteristics:
Sensitivity: 0.1 V
Input Impedance: 10,000 ohms
NOTE
If the frequency counter has variable gate
and display times, proceed-with steps band
.
b. Using Counter to Replace Instrument FREQUENCY Dial.
(1) Set counter GATE TIME to 0.01 second.
(2) If counter has MEMORY control, turn it on.
(3) Adjust counter DISPLAY control for minimum display time.
(4) Counter indicates frequency setting of the instrument 100 Hz.
c. Using Counter as a Tuned-to-Freguency Readout.
(1) Carefully adjust TUNING control so meter indicates maximum (peaked).
(2) Set frequency counter GATE TIME to 0.1 second.
(3) Adjust frequency counter DISPLAY control for a display time as short
as possible but easily readable.
(4) With a laO-Hz filter in the instrument, the frequency counter indi
cates the frequency to which the instrument is tuned 20 Hz.
d. A counter with fixed l-second gate time can also be used. Tuning to and
measuring a frequency is a little slower but just as accurate.
12 3 ~ 7 2
CHAPTER III
THEORY OF OPERATION
1. GENERAL.
The instrument employs a single conversion superheterodyne circuit with a
selectable bandpass of 250 (100) Hz or 2.5 kHz to measure frequencies in the
range 1 to 1500 kHz. Figure 11 is a functional block diagram of the instru
ment and figure 12 is the basic schematic diagram without the counter output
module. Figures l2A, l2B, and l2C show the different input circuits of the
three models. Figure 13 is a schematic diagram of the counter output module.
At the input of the instrument, a switch is used to select the input signal
from either the 250-kHz calibrate oscillator or from the front panel INPUT
jacks. A filter and matching network are incorporated into the input circuit
to attenuate unwanted high-frequency components and to provide proper imped
ances.
A variable attenuator provides up to 100 dB of attenuation in 10-dB steps tc
control sensitivity of the instrument. Tuning of the instrument is accomplished
by a variable local oscillator whose output varies from 2216 to 3715 kHz. The
input and local oscillator signals are heterodyned in a mixer to produce a
22l5-kHz difference frequency. The i-f amplifier is tuned to 2215 kHz and it
amplifies the mixer output.
The 250 (lOO)-Hz and 2.S-kHz selectivities of the instrument are determined by
crystal filters between the first and second i-f amplifiers. After amplifi
cation by the i-f amplifier, the signal is rectified and filtered in a meter
detector circuit and then applied to a meter.
The second detector, when used with insertion frequency of 2213.5 kHz and
2216.5 kHz will produce single sideband demodulation for audio monitoring.
The calibrate oscillator generates a 250-kHz square wave and is amplitude
regulated to provide an output level that is equivalent to -30 dBm at the
INPUT jacks. Before measurements are made, the instrument sensitivity is
calibrated by connecting the calibrate oscillator output to the instrument
input circuits and adjusting the i-f amplifier gain for a meter indication of
o dBm.
When the instrument is used for power measurements, the variable attenuator is
used to change sensitivity in calibrated steps of 10 dB. For example, assume
that a signal level of -42 dBm is applied to the instrument input. Adjusting
the ATTENUATOR to the -40 DB position will result in meter indication of -2
dBm. The input level is then determined by algebraically adding the meter
indication to the attenuator setting;
-40 dB + (-2 dBm) -42 dBm
3-72
13
2.
3.
4.
5.
6.
INPUT MODULE AI.
The input circuits are composed of INPUT SELECTOR switch Sl and a 100-dB
ATTENUATOR AIATI. Input signals are applied to INPUT binding posts AIEl and
AlE2. All models have 5000 ohms input impedance.
In Models 3l2lB and 3132, resistor AlRl, AlR2, or AIR3 is switched into the
circuit by AISI to terminate 75-, 135-, or 600-ohm lines. In Model 3l26B,
resistor AIR2 or AIR3 is switched into the circuit by AISI to terminate 135
or 600-ohm lines.
In Model 3l26B, resistors AIR4 and AIRS form a 6.S-dB L-pad, and are sWitched
into the circuit in INPUT SELECTOR positions 600 Ohms BRG or 600 Ohms TERM for
measurements on 600-ohm impedance lines. This allows one calibration to serve
for both 135-ohm and 600-ohm dBm measurements.
EMITTER-FOLLOWER AND CALIBRATE OSCILLATOR MODULE A2.
The function of the emitter-follower with feedback is to match attenuator AlATI
to lowpass filter FL3.
The calibrate oscillator is 250 kHZ, crystal-controlled, and biased so the out
put voltage swings between the regulated -power supply voltage and ground. The
output is applied through CAL OSC ADJ potentiometer A2Rl2 to switch AISI for
calibrating the instrument level and checking the frequency dial accuracy.
LOWPASS FILTER FL3.
The lowpass filter has a cutoff frequency of 1760 kHz and provides 60 dB of
attenuation at 2215 kHz. Input and output impedances are 150 ohms.
OSC ILLATOR-MODULATOR MODULE A3.
The input signal is heterodyned with the local oscillator injection signal in
balanced modulator diodes A3CRI. The diodes operate as a balanced shunt modu
lator, shorting the signal to ground during one-half the local oscillator cycle.
The 2215-kHz output of the modulator is capacitively coupled to the base of
first i-f amplifier A4Ql.
Modulator driver A3Q1 output is transformer-coupled through A3Tl to the modu
lator diodes. Local oscillator level at the junction of the modulator diodes
is very small due to the matching of components. Input to the modulator driver
is capacitively coupled from the emitter of local oscillator A3Q2.
The local oscillator is a modified Colpitts type with three switched frequency
bands. The frequency in each band is varied by adjusting TUNING capacitor CI,
an 11- to 150-picofarad air-dielectric capacitor. The oscillator circuit is
temperature-stabilized by A3CB.
IF AMPLIFIER MODULE A4.
The 2215-kHz output of the modulator is capacitively coupled to first i-f
amplifier A4Ql. The amplifier and filter driver consists of three stages:
14 3-72
A4Ql, A4Q2, and A4Q3. Total gain is 36 dB. Output of A4Q2 is transformer
coupled to A4Q3, the filter driver.
The instrument has two crystal filters which are selected by SELECTIVITY switch
A4S4. The center frequency of both filters is 2215 kHz and the bandwidths are
250(100)Hz (A4FLl) and 2.5 kHz (A4FL2) at 3 dB down. Trimmer capacitors A4C7
through A4ClO tune the filters for maximum flatness. Each filter has an input
impedance of 4000 ohms and an output impedance of 1000 ohms.
The filter matching amplifier and second i-f amplifier consists of three stages:
A4Q4, A4Q5, and A4Q6. Output of the crystal filter is capacitively coupled to
filter matching amplifier A4Q4-A4Q5. CAL LEVEL control R2 is used to adjust
bias current for A4Q5, thus controlling gain of the stage. The output of A4QS
drives common-emitter amplifier A4Q6. Second i-f amplifier A4Q6 has a gain of
20 to 40 dB, depending upon the setting of CAL LEVEL control R2.
Third i-f amplifier A4Q7 provides 30 dB of gain and is transformer-coupled to
i-f output amplifier A4Q8. Output of A4Q7 is also capacitively coupled to the
meter detector circuit.
Meter detector diode A4cRl is a half-wave detector with its output applied
through A4R27 to power switch S7, which is connected to the meter.
I-f output amplifier A4Q8 provides isolation of the carrier reinsertion
oscillator signal and also drives demodulator diodes ASCR2 and ASCR3.
7. DEMODULATOR MODULE AS.
The AM demodulator is a shunt type; AsCR3 is the diode. Monitor switch A5Ss,
when in the AM position, connects, the cathode of AsCR3 to ground. Rf filtering
is done by A5ClO and AsRls. The audio signal is capacitively coupled from
AUDIO LEVEL control Rl to the base of first audio amplifier ASQ5.
The sideband demodulator consists of AsCR2 and AsCR3, which are supplied with
carrier signal from ASQ4. These diodes operate as a balanced shunt demodulator
that shorts the i-f signal to ground during one-half the injection signal cycle.
This produces an audio difference signal that is coupled to the base of first
audio amplifier AsQs.
Carrier reinsertion oscillator AsQ3 is crystal-controlled by AsYI or AsY2.
Output is capacitively coupled to balanced phase splitter AsQ4, which supplies
out-of-phase signals to demodulator diodes AsCR2 and ASCR3. MONITOR switch
ASSS is used to apply power to AsQ3 and AsQ4, and select the crystal for LSB
or USB demodulation. LSB crystal AsYI is 1.5 kHz below and USB crystal ASY2 is
1.5 kHz above the i-f center of 2215 kHz.
8 ADD10 AMPLIFIER MODUL E AS.
The audio amplifier is composed of first audio amplifier ASQs and audio output
amplifier AsICl, an integrated circuit. The output of the demodulator is fed
through rf decoupling network AsRls and AsClO to AUDIO LEVEL control Ri. Sig
nal at the arm of Rl drives first audio amplifier AsQs. Gain of audio output
amplifier ASICI is approximately 28 dB.
3-72 15
9. REGULATOR MODULE AS.
The regulator is a series type, with A5Ql as the series regulator transistor
and A5Q2 the control amplifier. Reference diode A5VRl (9.1 volts) controls
bias for A5Q2. The output of the regulator is also connected through A5R4 to
POWER switch 87 for checking battery condition. Nickel-cadmium batteries hold
their full voltage throughout the useful life of the charge, thus a meter
indication of a O.5 dBm indicates that the battery charge is adequate for
instrument operation.
10. AC POWER SUPPLY AND CHARGER MODULE A6.
The ac power supply consists of Tl, A6CR1, A6Cl, A6Rl, and A6VRl. Voltage
applied to the regulator and to the audio amplifiers on module AS is
preregulated by A6VRl. The ac power supply also supplies charging current of
approximately 65 milliamperes to the battery when POWER switch 87 is in the
BAT. position. When the POWER switch is in the AC position, A6R2 is connected
in series with the battery to supply a trickle charge of approximately 5
milliamperes and isolate the battery from the preregulated line.
11. COUNTER OUTPUT MODULE A7.
Module A7 is usually installed in instruments with lOa-Hz selectivity but it
can be ordered with 250-Hz instruments. The purpose of the module is to
provide an output signal for accurate frequency measurements by an external
electronic frequency counter.
Figure 13 is the schematic diagram of the counter module.
A signal from local oscillator module A3 is connected through coaxial cable to
El of module A7. The signal goes through isolation amplifiers A7Ql and A7Q2
to pin 1 of product detector A7ICl. Transistor A7Q5 and associated components
form a crystal-controlled oscillator that is adjustable over the i-f of 2215
kHz. The output of this injection oscillator is coupled to pin 2 of A7ICI.
The output at pin 8 of A7lCl is the product of the local oscillator and the
injection oscillator outputs, and is applied to lowpass filter A7L2-A7L3.
Only the difference frequency is passed and applied to amplifier A7Q3. Tran
sistor A7Q4 provides a low output impedance through A7C12 to COUNTER output
connector J3 on the front panel of the instrument.
Counter output signal accuracy depends upon the accuracy of centering within
the bandpass of the lOO-Hz filter.
16 3-72
L
CHAPTER IV
MAINTENANCE
INTRODUCTION.
This instrument will give comparatively trouble-free performance provided
normal operating procedures are observed. In the event of any malfunction,
first check the battery by turning the POWER switch to the BAT. position and
observing the meter for an indication of 0 O.5 dB.
Before attempting to trouble shoot the instrument, you should study Chapter III,
Theory of Operation. The trouble-shooting procedure consists of three parts:
Isolation to a particular module
Module trouble shooting
Transistor voltage checks
2. TEST EQUIPMENT.
The test equipment of table 6 is required to test and align the instrument, but
it is not supplied.
Table 6. Test Equipment
NAME USE REQUIRED CHARACTERISTICS
Sweep Generator
and Display Unit
Vtvm
Frequency Counter
Signal Generator
Ac Vtvm
Align i-f amplifiers
and crystal filters
1. Center frequency between
50 and 500 kHz
2. Sweep width variable
from 5 to 40 kHz
3. Sweep rate: l/sec. to
4/sec.
Triplett 850 or equivalent
L Minimum counting rate
3000 kHz
2. Gate time 1 sec. and
0.01 sec.
3. Variable display time
Hewlett-Packard 651 or
equivalent
Ballantine 303 or
equivalent
3-72 17
3. TROUBLE SHOOTING.
Before proceeding with step 1 in table 7, connect equipment in the test setup
shown in figure 3 and perform the following steps:
a. Set instrument switches and controls as follows:
Swi tch/Control Position
INPUT SELECTOR BRIDGE
BAND SELECTOR A
TUNING 250 kHz
ATTENUATOR
-60 DB
CAL LEVEL
Fully clockwise
SELECTIVITY 2.5 kHz
b. Adjust signal generator for 0 . 7 8 ~ V , 250-kHz output signal.
SIGNAL
GENERATOR
RYCOM
AC VTVM INSTRUMENT
Figure 3
Test Setup for Module Isolation
Table 7. Module Isolation
STEP
1
2
3
PROCEDURE
Turn unit on. Activate
BAT. TEST.
Set INPUT SELECTOR to
BRIDGE. Connect ac
vtvm to pin 7 of
Module A2.
Set INPUT SELECTOR to
CAL. Connect ac vtvm
to pin 7 on Module A2.
NORMAL
INDICATION
Meter reads
o 0.5 dB.
Ac vtvm indicates
77 mV.
Ac vtvm indicates
2.5 mV.
IF IND ICATION
IS ABNORMAL
Battery needs recharge or
power supply regulator
Module AS. See table 8.
Trouble is in input Module
AI. See table 10.
Trouble is in calibrate
oscillator on Module A2.
See table 12.
18 3-72
Table 7. Module Isolation (Cont)
STEP PROCEDURE
NORMAL
INDICATION
IF INDICATION
IS ABNORMAL
4 Set INPUT SELECTOR to
BRIDGE. Connect ac
vtvm to pin 1 on Mod
ule A2.
Ac vtvrn
34 mV.
indicates Trouble is in emitter
follower on Module A2.
See table 11.
5 Connect ae vtvm to pin
E2 on Module M.
Ac vtvrn
30 mV.
indicates Trouble is in FL3 lowpass
filter. See table 13.
6 Set BAND SELECTOR to
A. Tune dial to zero
frequency.
Instrument meter
indicates past
full scale.
Trouble is in Module A3.
See table 14.
7 Tune dial to 250 kHz
and obtain 0 dB meter
reading. Set ATTEN
UATOR to +10 DB.
Connect ac vtvm to E6
on Module A4.
Ac vtvrn
0.15 V.
indicates Trouble is in Module A4.
See table 15.
8 Connect ac vtvrn to ElO
on Module A5. Set
MONITOR switch to LSB;
AUDIO LEVEL to 2/3 cwo
Ac vtvrn indicates
0.14 V.
Trouble is in reinsertion
oscillator Module AS. See
table 16.
9 Connect ac vtvrn
on Module AS.
to E12 Ac vtvrn
approx.
indicates
4 V.
I Trouble is in audio amp
lifier Module AS. See
table 17.
Table 8. Regulator Module A5 Trouble Shooting
STEP PROCEDURE
NORMAL
INDICATION
IF INDICATION
IS ABNORMAL
1
2
Connect vtvm to El on
Module A5.
Connect vtvm to El on
Module AS. Set POWER
switch to BAT.
Vtvm indicates
11.5 to 13.5 Vdc.
Vtvm indicates
11.5 to 13.5 Vdc.
Check battery connections.
Battery needs recharging.
Check switch S7 and
connections.
3-72 19
Table 8. Regulator Module A5 Trouble Shooting (Cont)
STEP PROCEDURE
NORMAL
INDICATION
IF IND ICAT ION
IS ABNORMAL
3 Connect vtvm to E7 on
Module AS. Set POWER
switch to BAT.
Vtvm indicates
9.1 Vdc.
Check A5Ql and A5Q2 volt
ages. See table 18.
Table 9. Power Supply and Charging Circuit Module A6 Trouble Shooting
STEP PROCEDURE
NORMAL
IiIDICATION
IF INDICATION
IS ABNORMAL
1 Connect vtvm to cathode
of A6VR1. Connect power
cord to 115 Vac. Set
POWER switch to AC.
Vtvm indicates 13.5
to 16.5 Vdc.
Check A6CR1, A6Cl,
A6Rl and A6VRl.
Table 10. Input Module Al Trouble Shooting
STEP PROCEDURE
NoRMAL
INDICATION
IF INDICATION
IS ABNORMAL
1
2
Set INPUT SELECTOR to
BRIDGE. Connect ae
vtvm to coaxial lead
from SI to ATI on
Module AI. Set ATTEN
UATOR to -80 DB.
Set INPUT SELECTOR to
BRIDGE. Connect BC
vtvm to pin 7 on Module
-A2. Set ATTENUATOR to
-80 DB.
Ac vtvm indicates
0.78 V.
Ac vtvm indicates
0.78 V.
Check AlCI and switch
AISI connections for
continuity.
Check AlS2.
20 3-72
STEP
1
STEP
1
2
Table 11. Bmitter-Fo110wer Module A2 Trouble Shooting
PROCEDURE
Set signal generator
to 250 kHz at -30 dBm
and connect to pin 7
of Module A2. Connect
ac vtvm to pin 1.
STEP PROCEDURE
1 Set INPUT SELECTOR to
CAL. Connect ac vtvrn
to pin 4 on Module A2.
NORMAL
INDICATION
IF INDICATION
IS ABNORMAL
Ac vtvrn
11 mV.
indicates Check A2Q1, A2Q3, and
A2Q4 voltages. See table
18.
Table 12. Calibrate Oscillator Module A2
NORMAL
INDICATION
Ac vtvm indicates
26 mV.
Trouble Shooting
IF INDICATION
IS ABNORMAL
Check A2Q2 voltages. See
table 18.
Table 13. Lowpass Filter FL3 Trouble Shooting
PROCEDURE
Set signal generator to
250 kHz at 24.5 mV and
connect to IN on FL3.
Connect ac vtvm to OUT
on FL3.
Connect ohmmeter from
pin IN to OUT on FL3.
NORMAL
INDICATION
Ac vtvrn indicates
22 mV.
IF INDICATION
IS ABNORMAL
Check continuity of FL3.
Ohnmeter indicates Trouble is in FL3.
2 ohms.
.
I
21 3-72
Table 14. Local Oscillator Module A3 Trouble Shooting
STEP PROCEDURE
NORMAL
INDICATION
IF INDICATION
IS ABNORMAL
1
2
Connect ae vtvm to
junction of A3Rl and
A3CRl.
Connect ac vtvm to
junction of A3R5 and
A3R6.
Ac vtvm indicates
0.55 V.
Ac vtvm indicates
between 0.15 and
0.3 v.
Check A3Ql and A3Q2
voltages. See table 18.
Check A3Q2 voltages.
See table 18.
Table 15. I-f Amplifier Module A4 Trouble Shooting
STEP PROCEDURE
NORMAL
INDICATION
IF u\TDICATION
IS ABNORMAL
1 Set signal generator
to 2215 kHz at -100
dB (7.75 uV) and
connect to E2 on
Module A4. Rotate
CAL LEVEL fully cwo
Set SELECTIVITY to
2.5 kHz.
Instrument 'indi
cates -6 dBm.
Adjust A4T1, A4T2, and
A4T3 for maximum indi
cation on meter. Check
A4Ql thru A4Q8 volt
ages. See table 18.
Table 16. Reinsertion Oscillator Module AS Trouble Shooting
STEP PROCEDURE
NORMAL
INDICATION
IF INDICATION
IS ABNORMAL
1 Set MONITOR to LSB.
Connect ac vtvm to
base of ASQ4.
Ac vtvm indicates
0.75 V.
Check A5Q3 voltages.
See table 18. Check
crystals.
2 Connect ac vtvm to
junction of A5C8
and A5R13.
Ac vtvm indicates
0.5 V.
Check A5Q4 voltages.
See table 18.
--..
22 3-72
Table 17. Audio Amplifier Module AS Trouble Shooting
STEP PROCEDURE
NORMAL
INDICATION
IF INDICATION
IS ABNORMAL
1
2
Set signal generator
to 1 kHz at 20 mV and
connect to E10 on Mod
ule AS. Rotate AUDIO
LEVEL control Rl fully
cwo Connect ac vtvm to
collector of ASQ5.
Connect ac vtvm to E12
on Module AS.
Ac vtvm indicates
150 mV.
Ac vtvm indicates
4 v.
Check ASQ5 voltages.
See table 18.
Check ASICl voltages.
See table 19.
Table 18. Transistor Voltage Chart
Set instrument controls:
1. No signal input
2. CAL LEVEL fully cw
3. MONITOR to LSB
4. INPUT SELECTOR to CAL
Readings taken with vtvm and should be 10%.
All voltages positive with respect to chassis ground.
TRANSISTOR MODULE EMITTER BASE COLLECTOR
A2 Q2 2.3 2.1 6.0
Q3 9.0 7.8 1. 70
Q4 1.1 1.70 9.0
Ql Source = 1.1 Gate = 0 Drain = 8.4
A3 Ql 1.85 2.3 6.8
Q2 1.6 2.0 8.0
Ql 3.3 3.9 9.5
Q2 2.6 3.3 9.5
Q3 1.35 2.0 4.6
Q4
1.9 2.5 9.0
Q5 1.2 1.9 3.6
Q6 2.2 2.8 8.9
Q7 0.9 1.5 C.8
Q8 1.5 2.2 5.0
A4
3-72
23
Table 18. Transistor Voltage Chart (Cont)
MODULE TRANSISTOR EMITTER BASE COLLECTOR
A5 Ql
Q2
Q3
Q4
Q5
9.5
0
1.3
1.7
0.4
10.3
0.65
1.5
2.0
1.-0
12.0
10.3
3.5
7.8
5.0
1
A7 Ql
Q2
Q3
Q4
Q5
La
0.4
0.46
5.6
5.8
1.66
La
La
6.22
5.5
9.47
9.47
6.22
8.74
9.4
Table 19. Integrated Circuit Voltages
INTEGRATED
CIRCUIT
PINS
1 2 3 4 5 6 7 8 12 14
Test conditions are same as those given in table 18.
A5ICl - -
7.0 - - -
6.0 - 1.3 1.3
A7ICl 4.2 1.45 - 0.75 4.2 9.47 4.2 8.98 - -
4. ALIGNMENT.
a. Calibrate Oscillator. Due to normal aging, or replacement of parts, it
may be necessary to calibrate the levelmeter. This is accomplished by
comparing the calibrate oscillator output level with a known external
source. Connect the equipment as shown in figure 4, then proceed with
steps (1) through (j.
FREQUENCY SIGNAL RYCOM
GENERATOR VTVM COUNTER INSTRUMENT
Figure 4
Test Setup for Level Calibration
24
3-72
(1) Set instrument switches and controls:
SWitch/Control Position
INPUT SELECTOR BRIDGE
SELECTIVITY 250(lOO)Hz
ATTENUATOR CAL -30 DB
BAND SELECTOR A
TUNING 250 kHz CAL on
FREQUENCY dial
(2) Adjust signal generator frequency to 2S0 kHz.
(3) Adjust signal generator output level to -30 dBm (24.5 mV).
(4) Adjust TUNING control for maximum indication on meter.
(5) Adjust CAL LEVEL for 0 dBm indication on meter.
(6) Set INPUT SELECTOR to CAL.
(7) Adjust TUNING control for maximum indication on meter.
(8) Adjust CAL OSC ADJ control A2R12 on Module A2 for 0 dBm indication
on meter. The instrument is now calibrated and ready for operation.
b. I-f Amplifier. The alignment of the 22l5-kHz i-f amplifier, Module A4,
is performed by using the internal 2S0-kHz calibrate oscillator as a
signal source. Proceed as follows:
(1) Set instrument switches and controls:
Switch/Control Position
INPUT SELECTOR CAL
ATTENUATOR CAL -30 DB
SELECTIVITY 250(lOO)Hz
BAND SELECTOR A
TUNING
Adjust for maximum
meter indication
NOTE
Module A4 cover must be in place before aligning.
(2) Adjust CAL LEVEL (and A4R5 if needed) so meter indicates in upper
one-half of scale.
(3) Adjust A4Tl, A4T2, and A4T3 with a nonmetallic tuning tool for max
imum meter indication.
3-72 25
(4) Adjust CAL LEVEL fully counterclockwise (minimum gain), then adjust
A4R5 for -2 dB meter indication.
(5) Check gain range by rotating CAL LEVEL to extreme clockwise position
(maximum gain). Meter should indicate approximately +1.5 dB with
ATTENUATOR switch set to -20 DB.
c. Crystal Filters A4FLl and A4FL2. Crystal filters A4FLl and A4FL2 on
Module A4 can be adjusted for passband flatness by using the internal
calibrate oscillator. Proceed as follows:
(1) Set instrument switches and controls:
Switch/Control Position
INPUT SELECTOR CAL
ATTENUATOR CAL -30 DB
SELECTIVITY 2.5 kHz
BAND SELECTOR A
TUNING 250 kHz CAL on
FREQUENCY dial
(2) Adjust TUNING so meter indicates in valley of passband ripple.
(3) Adjust A4C9 and A4C10 for maximum meter indication.
(4) Repeats steps ~ ) and (1) until filter A4FL2 passband ripple is
within 0.5 dB.
(5) Set SELECTIVITY to 250(100)Hz.
(6) Adjust TUNING so meter indicates in valley of passband ripple.
(7) Adjust A4C7 and A4C8 for maximum meter indication.
(8) Repeat steps ( ~ ) and (l) until filter A4FLl passband ripple is
within O.5 dB.
d. Local Oscillator.
(1) Connect equipment as shown in figure 5.
(2) Adjust equipment as follows:
Switch/Control Position
SIGNAL GENERATOR o dBm level output
INPUT SELECTOR BRIDGE
ATTENUATOR o DB
SELECTIVITY 250(lOO)Hz
FREQUENCY dial Align with notch in top of
red cursor FREQUENCY dial bezel
opening
26 3-72
FREQUENCY
COUNTER
~
I \ I
SIGNAL RYCOM
GENERATOR INSTRUMENT
X r
Figure 5
Test Setup fot' Frequency Alignment
(3) Band A Alignment.
(a) Set BAND SELECTOR to A.
(b) Adjust signal generator frequency to 50 kHz.
(c) Adjust TUNING for 50-kHz indication on FREQUENCY diat.
(d) Adjust A3L3 for maximum meter indication.
(e) Adjust signal generator frequency to 250 kHz.
(f) Adjust TUNING for 250-kHz indication on FREQUENCY dial.
(g) Adjust A3C14 for maximum meter indication.
(h) Repeat steps () through (a) until FREQUENCY dial tracks
within l kHz on band A.
(4 ) Band B Alignment.
(a) Set BAND SELECTOR to B.
(b) Adjust signal generator frequency to 350 kHz.
(c) Adjust TUNING for 350-kHz indication on FREQUENCY dial.
(d) Adjust A3C16 for maximum meter indication.
(e) Adjust signal generator frequency to 650 .kHz.
(f) Adjust TUNING for 650-kHz indication on FREQUENCY diaL
(g) Ad just A3C12 for maximum meter indication.
(h) Repeat steps
(!?)
through (a) until FREQUENCY dial tracks
within 2 kHz on band B.
(5 ) Band C Alignment.
(a) Set BAND SELECTOR to C.
(b) Adjust signal generator frequency to 1400 kHz.
3-72
27
(c) Adjust TUNING for 1400-kHz indication on FREQUENCY dial.
(d) Adjust A3CIO for maximum meter indication.
e. Counter Output. Bands A, B, and C must be aligned according to paragraph
4.i before the counter output module can be aligned.
(1) Very carefully center the signal in the bandpass of the 100-Hz
crystal filter by adjusting signal generator frequency for peak
indication on the meter. Note frequency counter indication.
(2) Remove cover from counter Module A7.
(3) Connect frequency counter to COUNTER jack.
(4) Carefully adjust A7Cl3 in counter module for the same frequency as
noted in step (l). Frequency should be within 20 Hz of that noted.
(5) Replace cover on counter module.
28 3-72
1.
2.
01121
01295
03508
03877
04713
CHAPTER V
PARTS LIST
HOW TO ORDER pARTS.
When ordering parts, always include:
a. Name, model, and serial number of the instrument.
b. Module and reference designation.
c. Part number.
d. Description.
Order parts from:
RYCCM INSTRUMENTS
9351 East 59th Street
Raytown, Missouri 64133
Telephone 816-353-2100
NOTE: $10.00 minimum on all orders.
LIST OF MANUFACTURERS.
Code is listed in parts list under MFR.
Name and Address Code Name and Address
Allen-Bradley Co. 05397 Union Carbide Corp., Lind Div.
1201 S. 2nd St. Kemet Dept.
Milwaukee, Wise. 53204 Cleveland, Ohio
Texas Instruments, Inc. 06978 Alladin Electronics
Semiconductor-Components Div. of Alladin Ind.
Div. 705 Murfreesboro Rd.
13500 N. Central Expressway Nashville, Tenn. 37210
Dallas, Tex. 75231
07109 Oaktron Industries
General Electric Co. P. O. Box 86
Semi-Conductor Products Monroe, Wise. 53566
Dept.
Electronics Park 07910 Continental Divice Corp.
Syracuse, N.Y. 13201 12515 Chad'ron Ave.
Hawthorne, Calif. 90250
Transitron Electronic Corp.
168-186 Albion St. 11236 CTS of Herne, Inc.
Wakefield, Mass. 01880 406 Parr Rd.
Berne, Ind. 46711
Motorola Semiconductor
Products, Inc. 11237 CTS Keene, Inc.
5005 E. McDowell Rd. 3230 Riverside Ave.
Phoenix, Ariz. 85005 Paso Robles, Calif. 93446
3-72 29
Code
13571
14752
16299
18410
24655
29309
34263
44655
49956
56289
70903
71400
Name and Address
Electronic Research Corp.
10005 W. 75th
Overland Park, Kans. 66204
Electro Cube, Inc.
1710 S. Del Mar Ave.
San Gabriel, Calif. 91776
Corning Glass Works
Electronic Components Div.
3900 Electronics Dr.
Raleigh, N.C. 27604
RYCOM INSTRUMENTS
RAILWAY COMMUNICATIONS,INC.
9351 E. 59th St.
Raytown, Mo. 64133
General Radio Co.
22 Baker Ave.
West Concord, Mass. 01781
Richey Electronics, Inc.
1307 Dickerson Rd.
Nashville, Tenn. 37213
CTS of Brownsville, Inc.
1100 Roosevelt St.
Brownsville, Tex. 78520
Ohmite Mfg. Co.
3601 W. Howard St.
Skokie, Ill. 60076
Raytheon Co.
Lexington, Mass. 02173
Sprague Electric Co.
North Adams, Mass. 01247
Beldon Corp.
415 S. Kilpatrick
Chicago, Ill. 60644
Bussmann Mfg.
Div. of McGraw Edison
2536 W. University St.
St. Louis, Mo. 63017
Code
71785
72136
72982
74970
79089
81073
82389
84411
87930
91637
95712
99848
Name and Address
Cinch Mfg. Co. and
Howard B. Jones Div.
1026 S. Homan Ave.
Chicago, Ill. 60624
Electro Motive Mfg. Co., Inc.
South Park and John Streets
Willimantic, Conn. 06226
Erie Technological Products,
Inc.
644 W. 12th St.
Erie, Pa. 16512
E. F. Johnson Co.
299 10th Ave. S. W.
Waseca, Minn. 56093
RCA Corp, Receiving Tube Div.
415 S. 5th St.
Harrison, N. J. 07029
Grayhill, Inc.
561 Hillgrove Ave.
La Grange, Ill. 60525
Switchcraft, Inc.
5555 N. Elston Ave.
Chicago, Ill. 60630
TRW Capacitor Div.
112 W. First St.
Ogallala, Nebr. 69153
Tower Mfg. Corp.
158 Pine St.
Providence, R.I. 02903
Dale Electronics, Inc.
P. O. Box 609
Columbus, Nebr. 68601
The Bendix Corp.,
Microwave Devices Div.
Hurricane Rd.
Franklin, Ind. 46131
Wilco Corp.
4030 W. 10th St.
P. O. Box 22248
Indianapolis, Ind. 46222
30 3-72
PARTS LIST
1
1
1
1
1
1
1
1
1
1
1
1
1
QTY/
REF DES DESCRIPTION PART NO. MFR
ASSY
PARTS LOCATED ON FRONT PANEL OR CHASSIS
BTl Battery, 12 V, 1.0 amp-hr, nickel-cadmium 41B001KD20 18410
C1 Cap, var, air, 11-150 pF, type L 167-153.. 10 18410 1
FL3 Filter, lowpass, 1.76 MHz cutoff 3121FL3 18410 1
frequency, 150 ohms input and output
impedance
J1 Connector, electrical power H1061-IG 87930
J2 Jack, headset L-12A 82389
J3 95712 Connector, BNC (used with Module A7) 4716-1
3121LlA 18410
L2
Ll Coil, rf, 15.6 uH
Suppressor, parasitic 3131L2 18410
LS1 Loudspeaker 3A1415 07109
M1 Mu1timeter, replacement, 0-200 uA, 3005-41 18410 1
500 ohms dc resistance
R1 Res, var, 25K 20%, 1/2 W WM4275A 11237
R2 Res, var, 10K 20%, 1/2 W NW8746 11237
R3 Res, 47 ohms 5%, 1/2 W, carbon EB4705 01121
S7 SWitch, rotary, 3-po1e, 4-pos, 1-deck 18410 3131S7
T1 Transformer, power 3085-1 18410
WA1 Cord Assy, power 17258S 70903
3-72 31
PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTY/
ASSY
MODULE Al (MODEL 3121B)
AIel
A1e2
Cap,
Cap,
5.0 uF
0.1 uF
20%, 200 wvdc, mylar
(-20% +80%), 25 wvdc, ceramic
X663FSOS02W
S81S000YSUOO
1042
84411
72982
1
1
AIEl
A1E2
Binding Post,
Binding Post,
red
black
29-1-R
29-1-B
81073
81073
1
1
Mounting Plate, black 29Bll-1 81073 1
A1R1
A1R2
A1RJ
AlR4
A1R5
AIR6
AlR7
AIR8
AIR9
AIRlO
A1R11
A1R12
A1R13
A1Rl4
AIR15
A1R16
A1R17
A1R18
A1R19
Res, 75 ohms 5%, 2 W, metal film
Res, 140 ohms 2%, 1 W at 125C, metal
film
Res, 681 ohms 1%, 1/4 W at 125C,
metal film
NOT USED
NOT USED
NOT USED
Res, 6040 ohms l%, 1/10 W at 12SoC,
metal film
Res, 3400 ohms 1%, 1/10 W at 125C,
metal film
Res, 1580 ohms 1%, 1/10 W at 125C,
metal film
Res, 4S30 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 499 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 4990 ohms 1%, 1/10 W at 125C,
metal film
Res, 4870 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 158 ohms 1%, 1/10 W at 125C,
metal film
Res, 4990 ohms, same as A1R12
Res, 49.9 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 4990 ohms, same as A1R12
Res, 15.8 ohms 1%, 1/10 W at 12SoC,
metal film
Res, lS.8 ohms, same as A1R18
Type c-42S
Type C-32
RY6SD6810F
RYS 7D6041F
RYS7D3401F
RYS 7DtS81F
RYS7D4S31F
RYS7D4990F
RYS 7D4991F
RYS 7D4871F
RYS7D1S80F
RYS7D49R9F
RYS7D1SR8F
16299
16299
18410
18410
18410
18410
18410
18410
18410
18410
18410
18410
18410
1
1
1
1
1
1
1
1
3
1
1
1
2
A1S1
A1S2
Switch,
Switch,
rotary
rotary
3121S1A
3121S2
18410
18410
1
1
3-72
32
PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTY./
ASSY
MODULE Al (MODEL 3126B)
AICI
AIC2
AIC3
Cap, 5.0 uF 20%, 200 wvdc, mylar
Cap, 0.1 uF (-20% +80%), 2S wvdc,
disc ceramic
Cap, 33 pF 5%, SOO wvdc, silver mica
X663FS0502W
5815000Y5UOO
1042
DM15E330J
84411
72982
72136
1
1
1
AIEl
AIE2
AlE)
Binding Post,
Binding Post,
Binding Post,
red
same as
black
AIEl
29.. 1-R
29-1-B
81073
81073
2
1
Mounting Plate 29B32-1 81073 1
Shorting Link 0938-9712 24655 1
A1J1 Connector,
Electric
electrical, 20-pin,
type KS-14160-L1
Western 47B14S1S 71785 1
A1R1
A1R2
A1RJ
A1R4
AIRS
A1R6
A1R7
A1R8
A1R9
A1RIO
A1Rll
A1R12
A1R13
A1R14
A1RI5
NOT USED
Res, 140 ohms 2%, 1 W at 12SoC, metal
film
Res, 681 ohms 1%, 1/4 W at 12SoC,
metal film
Res, 2610 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 4530 ohms 1%, 1/10 W' at 12SoC,
metal film
NOT USED
Res, 6040 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 3400 ohms 1%, 1/10 W at 12SoC,
metal film
Res, lS80 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 4S30 ohms, same as AIRS
Res, 499 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 4990 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 4870 ohms 1%, 1/10 W at 12SoC,
metal film
Res, lS8 ohms 1%, 1/10 W at 12SoC,
metal film
Res, 4990 ohms, same as AlR12
Type C-32
RY6SD6810F
RYS7D2611F
RYS7D4S31F
RYS7D6041F
RYS7D3401F
RYS7D1S81F
RYS7D4990F
RYS7D4991F
RYS 7D4871F
RYS7DlS80F
16299
18410
18410
18410
18410
18410
18410
18410
18410
18410
18410
I
1
1
1
2
1
1
1
1
3
1
1
3-72 33
PARTS LIST
QTYI
REF DES DES CR IPT ION MFR PART NO.
ASSY
MODULE A1 (MODEL 3126B)
A1R16 Res, 49.9 ohms 1%, 1/10 W at 125C,
metal film
A1R17 Res, 4990 ohms, same as A1R12
A1R18 Res, 15.8 ohms 1%, 1/10 W at 125C,
metal film
A1R19 Res, 15.8 ohms, same as A1R18
A1S1 Switch, rotary, 4-po1e, 9-pos, 2-deck
A1S2 Switch, rotary, 4-po1e, ll-pos, 4-deck
A1T1 Transformer, input, 1:1 turns ratio,
9.0 ohms 10% dc resistance
I
(Cont)
RY57D49R9F 18410
RY57D15R8F 18410
3126S1 18410
3121S2 1841G
3126A1T1 18410
1
2
1
1
1
34 3-72
PARTS LIST
QTY/
REF DES DESCRIPTION PART NO. MFR
ASSY
MODULE Al (MODEL 3132)
AlGI Cap, 5.0 uF 20%, 200 wvdc, mylar X663F50502W 84411 1
A1e2 Cap, 0.1 uF (-20% +8010), 25 wvdc, ceramic 5815000YSUOO 72982 1
l04z
AIEl Binding Post, red 29-1-R 81073 2
AIE2 Binding Post, same as AIEl
A1E3 Binding Post, black 29-1-B 81073 1
Mounting Plate 29B32-1 81073 1
A1RI Res, 75 ohms 5%, 2 W, metal film Type C-42S 16299 1
16299 1 A1R2 Res, 140 ohms 2%, 1 W at 125C, Type C-32
metal film
Res, 681 ohms 1%, 1/4 W at 125C, RY65D6810F 18410 1 A1R3
metal film
A1R4 NOT USED
A1R5 NOT USED
A1R6 NOT USED
A1R7 Res, 6040 ohms 1%, 1/10 W at 125C, RY57D6041F 18410 1
metal film
A1R8 Res, 3400 ohms 1%, 1/10 W at 125C, RY57D3401F 18410 1
metal film
A1R9 Res, 1580 ohms 1%, 1/10 W.at 125C, RY57D1581F 18410 1
metal film
A1R10 Res, 4530 ohms 1%, 1/10 W at 125C, RY57D4531F 18410 1
metal film
A1Rll Res, 499 ohms 1%, 1/10 W at 125C, RY57D4990F 18410 1
metal film
A1Rl2 Res, 4990 ohms 1%, 1/10 W at 125C, RY57D4991F 18410 3
metal film
A1R13 Res, 4870 ohms 1%, 1/10 Wat 125C, RY57D4871F 18410 1
metal film
A1R14 Res, 158 ohms 1%, 1/10 W at 125C, RY57D1580F 18410 1
metal film
Res, 4990 ohms, same as A1R12 A1R15
18410 1 RY57D49R9F Res, 49.9 ohms 1%, 1/10 W at 125C, A1R16
metal film
Res, 4990 ohms, same as A1R12 A1R17
2 18410 RY57D15R8F Res, 15.8 ohms 1%, 1/10 W at 125C, A1R18
metal film
Res, 15.8 ohms, same as A1R18 A1R19
3-72
35
pARTS LIST
QTY/
REF DES DESCRIPTION PART NO. MFR
ASSY
MODULE A1 (MODEL 3132) (Cont)
3131S1 1 18410 Switch, rotary, 4-po1e, 9-pos, 2-deck A1S1
3121S2 18410 SWitch, rotary, 4-po1e, 11-pos, 4-deck 1 A1S2
Transformer, input, 1:1 turns ratio, 3126A1T1 A1Tl 18410 1
9.0 ohms 10% dc resistance
......
-
36 3-72
PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTY/
ASSY
MODULE A2
A2Cl
A2C2
A2C3
A2C4
A2CS
A2C6
A2Ci
A2C8
A2C9
Cap, 15 pF 5%, 500 wvdc, silver mica
Cap, 0.01 uF 2ato, 200 wvdc, disc ceramic
Cap, 470 pF S%, 500 wvdc, silver mica
NOT USED
Cap, 10 uF 10 wvdc, tantalum
Cap, 0.1 uF (-20%, +80%), 25 wvdc,
disc ceramic
Cap, 10 uF, same as A2C5
Cap, 250 pF 5%, 500 wvdc, silver mica
Cap, 0.1 uF 10%, 200 wvdc, metalized
mylar
DM15ClS0J
0805030ZSUOO
103M
DM19E471J
KlOWlO
581S000YSUOO
1042
DM15E251J
210B1C104K
72136
72982
72136
05397
72982
72136
14752
1
1
1
2
1
1
1
A2Ll Coil, rf, 1.0 mR, 34 ohms de resistance UiOZ 99848 1
A2Ql
A2Q2
A2Q3
A2Q4
Transistor,
Transistor,
Transistor,
Transistor,
silicon, N-channel,
silicon, NPN
silicon, PNP
same as A2Q2
FET 400 0000
RC3710
2N4058
no 18410
18410
01295
1
2
1
I
A2Rl
A2R2
A2R3
AZR4
A2RS
A2R6
A2R7
A2R8
A2R9
A2R10
A2Rll
A1R12
A2R13
AZR14
A2R15
Res, 10,000 ohms 5%, 1/2 W, carbon
Res, 1 megohm 5%, 1/2 W, carbon
Res, 680 ohms 5%, 1/2 W, carbon
Res, 390 ohms 5%, 1/2 W,
Res, 1500 ohms 5%, 1/2 W, carbon
Res, 68 ohms 5%, 1/2 W, carbon
Res, 3300 ohms 5%, 1/2 W, carbon
Res, 2200 ohms 5%, 1/2 W, carbon
Nar USED
Res, 33,000 ohms 5%, 1/2 W, carbon
Res, 10,000 ohms, same as A2Rl
Res, var, 500 ohms 20%, 1/8 W, comp
Res, 100 ohms 5%, 1/2 W, carbon
Res, 1100 ohms 5%, 1/2 W, carbon
Res, 150 ohms 5%, 1/2 W, carbon
EBi035
EB1055
EB6815
EB3915
EB1525
EB68"05
EB3325
EB2225
EB3335
220S501B
EBI015
EB1125
EB1515
01121
01121
01121
01121
01121
01121
01121
01121
01121
34263
01121
01121
01121
2
1
1
1
1
1
1
1
1
1
1
1
1
AZYI Crystal, 250.0000 kRz Type CR-46A/
U
1:3571 1
3-72
37
PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTY!
ASSY
MODULE A3
A3Cl Cap, 0.1 uF (-20%, +80%),
disc ceramic
25 wvdc, 5815000Y5UOO
104Z
72982 1
A3C2
A3C3
A3C4
Cap, 0.1 uF 10%, 200 wvdc, meta1ized
mylar
Cap, 0.1 uF, same as A3C2
Cap, 0.01 uF 20%, 200 wvdc, disc
ceramic
2l0BlCl04K
0805030Z5UOO
103M
14752
72982
3
2
A3C5
A3C6
A3C7
A3C8
A3C9
A3C10
A3Cll
Cap, 0.1 uF, same as A3C2
Cap, 1500 pF 5%, 500 wvdc, silver mica
Cap, 4000 pF 5%, 500 wvdc, silver mica
Cap, 47 pF 5%, 200 wvdc, N470, disc
ceramic (temperature coefficient
selected as required)
Cap, 27 pF 5%, 500 wvdc, NPO disc
ceramic
Cap, ver, 1.7-20 pF, air dielectric
Cap, 110 pF 5%, 500 wvdc, NPO disc
ceramic
DM19E152J
DM19E402J
0805000T2H04
70J
0851000COG02
70J
193-6-5
0841000COG01
11J
72136
72136
72982
72982
74970
72982
1
1
1
1
2
1
A3C12
A3C13
Cap, var, 1.7-20 pF, same as A3C10
Cap, 155 pF 5%, 200 wvdc, N080 disc
ceramic
0845030U1GOl
550J
72982 1
A3C14
A3C15
A3C16
A3C17
Cap, var, 2.2-34 pF, air dielectric
Cap, 535 pF l%, 500 wvdc, silver mica
Cap, var, 2.2-34 pF, same as A3C14
Cap, 33 pF 5%, 200 wvdc, NPO disc
ceramic
193-10-5
DM19E5350F
0805000COG03
30J
74970
72136
72982
2
1
1
A3C18
A3C19
Cap,
Cap,
0.01 uF, same as A3C4
22 pF 5%, 500 wvdc, silver mica DM15C220J 72136 1
A3CRl Diodes, matched pair RY3605 18410 1
A3L1
A3L2
A3L3
A3L4
Coil, rf,
Coil, rf,
Coil, rf,
Coil, rf,
1.0 roB
150 uH
var, 1.5-3.1 uH
150 uH, same as A3L2
Ul02
3150-12
3121L3A
99848
99848
18410
1
2
1
A3Ql
A3Q2
Transistor,
Transistor,
NPN
same as A3Q1
RC3710 18410 2
38 3-72
PARTS LIST
-
QTYI
REF DES DESCRIPTION PART NO. MFR
ASSY
MODULE A3 (Cont)
A3R1 Res, 68 ohms 5%, 1/2 W, carbon EB6805 01121 2
A3R2 Res, 68 ohms, Bame as A3R1
A3R3 Res, 680 ohms 5%, 1/2 W, carbon EB6815 01121 1
A3R4 Res, 1000 ohms 5%, 1/2 W, carbon EBl025 01121 3
A3R5 Res, 3300 ohms 5%, 1/2 W, carbon EB3325 01121 1
A3R6 Res, 10,000 ohms 5%, 1/2 W, carbon EBI035 01121 2
A3R7 Res, 10,000 ohms, same as A3R6
A3R8 Res, 2700 ohms 5%, 1/2 W, carbon 01121 1 EB2725
A3R9 Res, 1000 ohms, same as A3R4
A3RIO Res, 1000 ohms, same as A3R4
EB4705 01121 1
A3S3
Res, 47 ohms S%, 1/2 W, carbon A3Rll
3l21S3A 18410 1
A3T1
Switch, rotary
1 Transformer, balanced demodulator 58-122-02 06978
I
I
I
3-72 39
PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTY/
ASSY
MODULE A4
A4cl Cap, 0.01 uF i20%, 200 wvdc, disc ceramic 0805D3025UOO 72982 6
103M
A4C2 Cap, 0.1 uF +80%), 25 wvdc, disc 5815DDDY5UDD 72982 10
ceramic 1042
A4C3 0.1 uF ilO%, 200 wvdc, metalized 21DB1C1D4K 14752 4
mylar
A4c4 Cap, 0.1 uF, same as A4C2
A4c5 Cap, 0.1 uF, same as A4C2
A4C6 Cap, 0.01 uF, same as A4cl
A4C7 Cap, var, 5-25 pF, 350 wvdc, NPO ceramic 055705lCOP03 72982 4
9R
A4C8 Cap, var, 5-25 pF, same as A4C7
A4C9 Cap, var, 5-25 pF, \lame as A4C7
A4cIO Cap, var, 5-25 pF, same as A4C7
A4Cll Cap, 68 pF i5%, 500 wvdc, silver mica DM15E680J 72136 1
A4C12 Cap, 0.01 uF, same as A4Cl
A4c13 Cap, 0.1 uF, same as A4C3
A4c14 Cap, 0.1 uF, same as A4C2
A4C15 Cap, 0.1 uF, same as A4C2
A4C16 Cap, 0.01 uF, same as A4Cl
A4C17 Cap, 0.1 uF, same as A4C3
A4C18 Cap, 0.1 uF, same as A4C2
A4c19 Cap, 0.1 uF, same as A4C2
A4C20 Cap, 0.1 uF, same as A4C2
A4c21 Cap, 0.01 uF, same as A4c1
A4C22 Cap, 0.1 uF, same as A4c3
A4c23 Cap, 0.1 uF, same as A4C2
A4c24 Cap, 0.1 uF, same as A4c2
A4C25 Cap, 0.01 uF, same as A4cl
A4CR1 Diode, germanium lN277 03877 1
A4FLl Filter, bandpass, 2215 kHz, lOO-Hz 3121FLl-l06 18410 1
BW (used in units with lOO-Hz
selectivity)
A4FLl Filter, bandpass, 2215 kHZ, BW 3l21FLl 18410 1
A4FL2 Filter, bandpass, 2215 kHz, 2500-Hz BW 3121FL2 18410 1
A4Ll Coil, rf, 1.0 mH, 34 ohms dc resistance Ul02 99848 3
A4L2 Coil, rf, 1.0 mH, same as A4Ll
A4L3 Coil, rf, 1.0 mH, same as A4Ll
40

PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTYI
ASSY
MODULE A4 (Cont
A4Ql Transistor, silicon, NPN RC3710 18410
7
(used in units with 2S0-Hz selectivity)
A4Ql Transistor, silicon, NPN 2N4l24
04713 7
(used in units with 100-Hz selectivity)
A4Q2 Transistor, same as A4Q1
A4Q3 Transistor, same as A4Ql
A4fi+ Transistor, same as A4Ql
A4Q5 Transistor, same 8S A4Ql
A4Q6 Transistor, silicon, NPN 2N4124 04713 1
A4Q7 Transistor, same 8S A4Ql
A4Q8 Transistor, same 8S A4Ql
A4Rl Res, 200 ohms 5%, 1/2 W, carbon EB2015 01121 1
A4R2 Res, 6200 ohms 5%, 1/2 W, carbon EB6225 01121 1
A4R3 Res, 4300 ohms 5%, 1/2 W, carbon EB4325 01121 1
A4R4 Res, 10,000 ohms 5%, 1/2 W, carbon EBI035 01121 7
A4R5 Res, var, 200 ohms 20%, 1/2 W, carbon 362Y201B 11236 1
A4R6 Res, 680 ohms S%, 1/2 W, carbon EB681S 01121 3
A4R7 Res, 10,000 ohms, same as A4R4
A4R8 Res, 2700 ohms S%, 1/2 W, carbon EB272S 01121 2
A4R9 Res, 3900 ohms S%, 1/2 W, carbon
EB3925 01121 2
A4R10 Res, 390 ohms 5%, 1/2 W, carbon
EB3915 01121 3
A4Rll Res, 680 ohms, same as A4R6
A4R12
A4R13
Res,
Res,
1100 ohms S/o, 1/2 W,' carbon
47,000 ohms 5%, 1/2 W, carbon
EB112S
EB473S
01121
01121
1
1
A4R14 Res, 18,000 ohms S%, 1/2 W, carbon EB1835 01121 1
A4RlS Res, 10,000 ohms, same as A4R4
A4Rl6 Res, 3900 ohms, same as A4R9
A4R17 Res, 1000 ohms S%, 1/2 W, carbon EB1025 01121 3
A4R18 NOT USED
A4R19 Res, 10,000 ohms, same as A4R4
A4R20 Res, 4700 ohms 5%, 1/2 W, carbon
EB4725 01121 1
A4R21 Res, 1000 ohms, same as A4R17
A4R22 Res, 10,000 ohms, same as 4R4
A4R23 Res, 2200 ohms 5%, 1/2 W, carbon EB2225 01121 1
A4R24 Res, 390 ohms, same as A4R10
A4R25 Res, 10,000 ohms, same as A4R4
A4R26
A4R27
Res,
Res,
27,000 ohms S%, 1/2 W, carbon
1000 ohms, same as A4Rl7
EB2735 01121 1
A4R28 Res, 10,000 ohms, same as A4R4
3-72
41
PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTY/
ASSY
MODULE A4 (Cont)
A4R29
A4R30
A4R31
A4R32
A4R33
A4R34
A4s4
A4T1
A4T2
A4T3
Res, 3300 ohms 5%, 1/2 W, carbon
Res, 2700 ohms, same as A4R8
Res, 390 ohms, same as A4R10
Res, 680 ohms, same as A4R6
Res, 1000 ohms min., 3000 ohms max.
5%, 1/2 W, carbon
(used in 100-Hz selectivity units only)
Res, 12,000 ohms 5%, 1/2 W, carbon
(used in 100-Hz selectivity unit only
if needed)
I EB3325
I EB Type
I EB1235
01121
01121
01121
1
1
1
Switch, rotary,
circuit type
2-po1e, 2-pos, printed I 3121S4 18410 1
Transformer,
Transformer,
Transformer,
i-f,
same
same
2215 kHz
as A4T1
as A4T1
I B3807 18410 3
42 3-72
PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTY!
ASSY
MODULE AS
ASCI
ASC2
ASC3
ASC4
ASC5
ASC6
ASC7
ASC8
ASC9
ASClO
ASCll
ASC12
ASC13
A5C14
A5C1S
A5C16
ASC17
A5C18
Cap, 10 uF (-10%, +100%), 15 wvdc, dry
electrolytic
NOT USED
Cap, 0.1 uF 10%, 200 wvdc, meta1ized
mylar
Cap, 200 pF 5%, 500 wvdc, silver mica
Cap, 0.1 uF (-20%, +80%), 25 wvdc,
disc ceramic
Cap, 59 pF 5%, 500 wvdc, silver mica
Cap, 0.01 uF 20%, 200 wvdc, disc ceramic
Cap, 0.01 uF, same as AsC7
Cap, 0.01 uF, same as AsC7
Cap, 0.01 uF, same as AsC7
Cap, 0.1 uF, same as AsC5
Cap, 0.01 uF, same as A5C7
Cap,. 0.01 uF, same as A5C7
Cap, 0.001 uF 20%, 500 wvdc, disc
ceramic
Cap, 10 uF 20%, 10 wvdc, tantalum
Cap, 10 uF, same as A5C1
Cap, 22 uF 20%, 6 wvdc, tantalum
Cap, 0.1 uF, same as ASC5
30D106G015BA
2
21OB1C104K
DM15E201J
S81S000Y5UOO
104Z
DM1SE590J
080S030ZSUOO
103M
831000Z5UOOI
02M
KlOW10
K22W6
56289
14752
72136
72982
72136
72982
72982
05397
05397
2
1
1
3
1
6
1
1
1
ASCR1
ASCR2
A5CR3
NOT USED
Diode
Diode, same as A5CR2
1N277 03877 2
ASIC1 Integrated Circuit GEL237Fl 03508 1
ASL1 Coil, rf, 1. 0 rnH Ul02 99848 1
ASQl
A5Q2
A5Q3
A5Q4
A5Q5
Transistor,
Transistor,
Transistor,
Transistor,
Transistor,
NPN
NPN
same
same
same
as
as
as
ASQ2
A5Q2
A5Q2
2N3053
RC3710
79089
18410
1
4
A5R1
AsR2
Res,
Res,
1000 ohms 5%, 1/2 W, carbon
820 ohms 5%, 1/2 W, carbon
EB1025
EB8215
01121
01121
4
2
3-72 43
PARTS LIST
REF DES DESCRIPTION PART NO. MFR
QTY/
ASSY
MODULE A5 (Cont)
ASR3
ASR4
A5R5
ASR6
A5R7
A5R8
ASR9
A5R10
A5R11
ASR12
A5R13
ASR14
A5R15
A5R16
A5R17
A5Rl8
A5R19
A5R20
A5R21
A5R22
ASR23
ASR24
NOT USED
Res, 60,400 ohms 1%, 1/8 W at 125C,
metal film
Res, 10,000 ohms 5%, 1/2 W, carbon
Res, 2000 ohms 5%, 1/2 W, carbon
Res, 4700 ohms 5%, 1/2 W, carbon
Res, 1000 ohms, same as A5Rl
Res, 8200 ohms 5%, 1/2 W, carbon
Res, 2200 ohms 5%, 1/2 W, carbon
Res, 1000 ohms, same as A5Rl
Res, 1000 ohms, same as A5Rl
Res, 4700 ohms, same as A5R7
Res, 4700 ohms, same as A5R7
Res, 3900 ohms 5%, 1/2 W, carbon
Res, 15,000 ohms 5%, 1/2 W, carbon
Res, 150,000 ohms 5%, 1/2 W, carbQn
Res, 15,000 ohms, same as A5R16
Res, 820 ohms, same as A5R2
Res, 390,000 ohms 5%, 1/2 W, carbon
Res, 56,000 ohms 5%, 1/2 W, carbon
Res, 15,000 ohms, same as A5R16
Res, 56,000 ohms, same as A5R21
Res, 180,000 ohms 5%, 1/2 W, carbon
RY60D6042F
EBI035
EB2025
EB4725
EB8225
EB2225
EB3925
EB1535
EB1545
EB3945
EB5635
EB1845
18410
01121
01121
01121
01121
01121
01121
01121
01121
01121
01121
01121
1
1
1
3
1
1
1
3
1
1
2
1
A5S5 S ~ i t c h , rotary 3121S5 18410 1
A5VR1 Diode, Zener IN960B 07910 1
A5Y1
ASY2
Crystal,
Crystal,
2213.5
2216.5
kHz
kHz
159
160
13571
13571
1
1
44 3-72
PARTS LIST
REF DES
A6c1
A6CRl
A6R1
A6R2
A6VRl
.....
Cap, 250 uF (
wvdc, dry electrolytic
Diode, full-wave
100 piv
Res, 200 ohms
Res, 820 ohms
Diode, Zener,
DESCRIPTION
-
PART NO. MFR
QTY/
ASSY
MODULE A6
+l 00% ) at 85C, 50
bridge, t. 0 amp,
5%, 5 W, wire-wound
5%, 1/2 W, carbon
15 V 10%, 10 W
10/0 , JA-13-250-50
-8P
FWBTS3001
4599
EB8215
1N2979A
29309
72982
44655
01121
04713
1
1
1
1
1
.
3-72 45
PARTS LIST
DESCRIPTION rREF DES
MODULE A7
Cap, 0.01 uF 20%, 200 wvdc, ceramic A7C1
A7C2 Cap, 0.1 uF (-20%, +80%), 25 wvdc,
ceramic
A7C3 Cap, 0.22 uF 20%, 12 wvdc, ceramic
A7C4 eap, 10 uF 20%, 10 wvdc, tantalum
A7C5 Cap, 180 pF 5%, 500 wvdc, mica
A7C6 Cap, 250 pF 5%, 500 wvdc, mica
A7C7 Cap, 270 pF 5%, 500 wvdc, mica
A7C8 Cap, 250 pF, same as A7C6
A7C9 Cap, 180 pF, same as A7C5
A7e10 Cap, 10 uF, same as A7C4
A7Cll Cap, 10 uF, same as A7C4
A7C12 Cap, 10 uF, same as A7C4
A7C13 Cap, var, 5.5-18 pF, 350 wvdc, NPO.
ceramic
A7C14 Cap, 30 pF 5%, 500 wvdc, mica
(nominal value)
A7C15 Cap, 300 pF 5%, 500 wvdc, mica
A7C16 Cap, 200 pF 5%, 500 wvdc, mica
A7C17 Cap, 110 pF 5%, 500 wvdc, mica
A7C18 Cap, 0.01 uF, same as A7C1
A7C19 Cap, 0.1 uF, same as A7C2
Integrated Circuit, monolithic, silicon A7IC1
A7Ll Coil, rf, 1 mH
A7L2 Coil Assy, 2 incapsulated coils,
28.5 mH and 100 mH
A7L3 Coil ABSY, same as A7L2
A7IA Coil, rf, 1 mH, same as A7L1
A7L5 Coil, rf, 47 uH
A7Ql Transistor, silicon, NPN
A7Q2 Transistor, same as A7Q1
A7Q3 Transistor, same as A7Q1
A7Q4 Transistor, same as A7Ql
A7Q5 Transistor, same as A7Q1
PART NO. MFR
QTY/
ASSY
0805030Z5UOO 72982 2 ,
103M
5815000Y5UOO 72982 2
104Z
5615000Y5FOO 72982 1
224M
K10W10 05397 4
DM15E181J 72136 2
DM15E251J 72136 2
DM15E271J 72136 1
5380115.518A 72982 1
DM15E300J 72136 1
DM15E30lJ 72136 1
DM15E201J 72136 1
DM15El11J 72136 1
CA3028A 79089 1
Ul02 99848 2
3071-71 18410 2
3071-81 18410 1
RC3710 18410 5
46 3-72
PARTS LIST
REF DES
A7R1
A7R2
A7R3
A7R4
A7R5
A7R6
A7R7
A7R8
A7R9
A7R10
A7Rll
A7R12
A7R13
A7Rl4
A7R15
A7R16
A7R17
A7R18
A7R19
A7R20
A7R21
Anl
DESCRIPTION
MODULE A7
Res, 270 ohms 5/0, 1/4 W, carbon
Res, 18,000 ohms 5%, 1/4 W,
Res, 3900 ohms 5/0, 1/4 W, carbon
Res, 1500 ohms 5/0, 1/4 W, carbon
Res, 820 ohms 5/0, 1/4 W, carbon
Res, 2200 ohms 5/0, 1/4 W, carbon
Res, 2200 ohms, same as A7R6
Res, 1000 ohms 5/0, 1/4 W, carbon
Res, 820 ohms, same as A7R5
Res, 180 ohms S/o, 1/4 W, carbon
Res, 620 ohms S/o, 1/4 W, carbon
Res, 1500 ohms, same as A7R4
Res, 270 ohms, same as A7R1
Res, 39,000 ohms 5%, 1/4 W,
Res, 10,000 ohms 5/0, 1/4 W,
Res, 2700 ohms 5/0, 1/4 W, carbon
Res, 100,000 ohms S%, 1/4 W,
Res, 15,000 ohms 5/0, 1/4 W,
Res, 22,000 ohms 5%, 1/4 W,
Res, 4700 ohms 5/0, 1/4 W, carbon
Res, 1500 ohms, same as A7R4
Crystal, quartz, 2215 kHz
QTY./
MFR PART NO.
ASSY
(Cont)
CB2715 01121 2
carbon CB1835 01121 1
CB3925 01121 1
CB1525 01121 3
CB8215 01121 2
CB2225 01121 2
CB102S 01121 1
1 CB1815 01121
1 CB6215 01121
01121 1 CB3935 carbon
1 01121 carbon CBI035
1 CB2725 01121
carbon CB1045 01121 1
1 01121 carbon CB1535
1 carbon CB2235 01121
CB4725 01121 1
18410 1 3071-181
3-72
47

o
o
8 ()
<>-i RI3
100

@
03
B 2N4058

.
_8 1"''' - s
U .G 01 -:
+ """'000"0
o
TERM
:=Y
4
5

8
Figure 6
Module A'4.
WIRE
COLOR
COAX
WHT-GRN
WHT-R
COAX
RED

u 0
G5 53;)
CI6 -
2,2.34 @E6
Q7 C9
qp
QI3 J5C CCII 110
1
ffiffiffi
CI4 2,2-34 CI2 1.7-20 CIO 1,7-20
o
BUS
BUS
WIRE
COLOR
A3E3
A3E5
TERM
A3El-A----COAX
A3E2---.r
L4
A3E6 BUS

A3E8
A3E4
UNITS WITH
MODULE A7
........
.......
Figure 7
Module A3
.......,
48 3-72
WIRE

, @ TERM COLOR

A4E1 RED
", ot;
C.. [] .0
o I- _ C3 a,lUD
A4E2 COAX
5 ::;(9) 0
A4E3 BUS
r
A4E4 WHT-YEL
0
A4E5 WHT-VIO
COAX
A4E6=9
A4E8
A4E7 RED
NOTES:
1. 100Hz SELECTIVITY units: Transistors
Q1 thru Q8 are type 2N4124 and are
positioned same as Q6.
2. Board shown is for 250Hz SELECTIVITY
units except as noted.
3. R33, R34 used only in units with
100Hz SELECTIVITY. R34 deleted and
bus used in place of R33 in units
with 250Hz SELECTIVITY.
"
3
o o
o
o
Figure 8
Module A4
3-72 49
IN960B


a1 r.


CIO
CD
EIO
@
GIB o.lUD EI2
@
+!22UFIC17 n

q ""

,,0
R I -10 It')
6 - .. -
c;QDC12 c' B
'"'05
RC3710
EII@ CII .1

-llilL.-J -
....



S!0r<lO
U _p
TERM
ASEl
ASE2
ASE3
ASE4
ASES
ASE6
ASE7

ASE8
ASE10
ASEll
ASE12
ASE13
WIRE
COLOR
RED-BLK
RED
Not used
Not used
ORN
RED
RED
COAX
GRN
WHT-GRN
BLU
BLK

Figure 9
Module A5
TERM
A7El
?
A7E2

A7E4
WIRE
COLOR
COAX
RED
COAX
-;
--..
--.,
Figure 10
Module A7
50
3-72
I
(
r
W
......
N
INPUT EMITTER LOW PASS 1ST I F
INPUT

SELECTOR l- FOLLOWER AMPLIFIER I-- FILTER
FILTER
DRIVER
A4Q3
COUNTER
OUTPUT
A7QI-A7Q5
I
SELECTABLE
BAND PASS
FILTER
FLI - FL2
I-
ALTER
MATCHING
AMPLIFIER
A4Q4-A4Q5
l
AISI FL3 A4QI-A4Q2
-
ATTENUATOR
AIATI
A2Q1. A203-A2Q4
-
f
2215 - 3715KC CALIBRATE
OSCILLATOR LOCAL
I F OUTPUT
AMPLIFIER
A4QB
BALANCED
MODULATOR
A3CRI
AM -SSB
DEMOOUI.ATOR
ASCR2-ASCR3
f--COUNTER I-
MODULATOR
DRIVER
A3QI
250KC OSCILLATOR
A2Q2 A3Q2
r
l
2ND IF 3RD I F 1ST AUDIO AUDIO OUTPUT
AMPLIFIER
ASICI
r
r
I-- AMPLIFIER AMPLIFIER
I--
AMPLIFIER I- I
A4Q7 A4Q6 A5Q5
1 f
CARRIER
METER METER AND REINSERTION
DETECTOR SELECTOR f
MCRI CIRCUITS
A5Q3,A5Q4
115VAC
II>lPUT
POWER SUPPLY
REGULATOR
A6CRI
A5QI-A5Q2
-
AND
CHARGER .
I>lICAI).
BATTERY
BTl
9.4V DC REGULATED
12V DC UNREGULATED
.... Figure 11

VI' Block Diagram


N
VI
-----------
I
L
RB 3.400 R9 1,580
......------------'
RII
499
RI6 49.9
RI4 158
6
RI9
15.8
R7 6,040
OUT
IN ----,
S2-SEC A S2-SEC B
(FRONT) (FRONT)
r - - -- - - -- - --(- -- - - - - - R12- - - - - - - - - -
: "4.990
\
IATTEN'UATORI
_----OB-----, , S2
r--
VOLTS
-----,
SEC
S,2
"
;:c
I . CAL, I
A

(REAR)
-40 .01 -30(3 ,\ -20

RI7
RI8
4,990
15.8
-70 3 tlO
-80 .0001 10 +20

ATTENUATOR ATI PART OF MODULE AI ABOVE
rAI
r
I
I
I
EI 5.0UF
@-...-ooool)I---.....--...,
51
(FRONT)
2
,
\
3
'
7 6
R3 RI R2
681 140 75
E2

IINPUT SELECTORr - - - - - - - -i
O
/75<1.
1
..---135<>.-TERM
-600",,-.J
'- BRIDGE
'--CAL
CI
I
I
I
:
I
:
I
-=
I
TO A2E7
,
I
1
I
I
I
I
I I
I
,
I
I
I
I
1
I 4
I
I
I ,
J. J 5
I
I
I
I
TO A2E5
C2
T.lUF
TO A2E4
TO A5E2
J
Figure 12A
3121B Input, Schematic
3-72
53/54
----------
PART JI
1:( i
3) I
({-. 3 I' L GR -D...--6004\ ....
14>: OlaF -= r
GR
- --,35tl.
TERNl
I
.........
4
OUT-W,;----./ / "--eoo",,--,
:$ :
II
-
L-E I
51-SEC A
1\
_I
I I TO A2E7
EI (REAR) CI ATI
'-'
5.0UF
:SEE t
I
I
PART OF - OF ATI 8ELOW)
JI
i
I
It
,
I
,
"'[l)-. 4
4) I
f: 3 :
R2
I
15) I
140
i


I
76
1'\ I
R3
I
SISEC B :
681
IBALI E2
(REAR) RED BRN
I
(FRONT) ,
/5
I
I TI
"'=/
I
I
I
I
YEL ORN
I

TO A2E5
DISCONNECT
I
BAR
'II
FOR
" 3
I
BAl.ANCED
0
OPERATION
I TO A2E4
51-SEC C I
(REAR)
I
---:l.
-b
I
TO A5E2
E3 -=
I
J
-- - -- --------...
AI I
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -I INPUT SELECTORI
1\

,=- 3 :
--'" I

8 7 6) 5 I
51-SEC A I
(FRONT) I
I
I
,
,
,
,
,
, C
CAL
I
Ih I
:
I
1 2,610. 4,530
0'

I
51-SEC C 6
(FRONT)
::::r: C3
33
R76,040 OUT
R83.400 RS 1,580
RIl
499
R14
_ 'V1/'''o/58 __..
RI6 49.9
IN ---.,
52-SEC A 52-SEC B
(FRONT) (FRONT)
r-- -- ----- --- - -- --
I , "
0.1 A""'n"'E"'N""UA""'T"'O=RI " "
r-----DB "52" 52
(0). (0). SEC SEC
A B

-30 ,03 (REAR) IRE


O
1
:)0

(;
\:: 3
-60 ,0001 10 +20 11t--.....----------
RI9
15.8
RI7
4,990
52
SEC
C
(FRONT I
/
I
I
I
- L-_-.M,......-1H-......
12
.....
ATTENUATOR ATI PART OF MODULE AI ABOVE
Figure 12B
3126B Input, Schematic
3-72
55/56
------
TI
TO A2E7
II
REO
TO A2E5
IC2
TO.IUF
TO A2E4
51 SEC B (REAR)
(FRONT)
TO A5E2
L
BRN
, RI
,
75
"
I
.. -." ..
,
R2
140
R3
681
r----u------!INPUT SELECTOR I
I B CAL U
: B RIDGE---,. I BRIDGE N
: T".---.\ //" "'0-
i 135'" -0 135'"
: 75'" ./ ' 75 A C
\ 0 TERMINATED' 5
,
,
,
,
,
E3
51 SEC A
IINPUTI
(FRONT)
=
51 SEC A
(REAR)
51 SEC B
EI
E2
JI
R7 6,040
RII
499
RS 1,580 R83,4oo
52-SEC B
( FRCIlTl
S2-5EC A
(FRONT)
IN ---.,
,/ 7
I
I
r---- --- -- --- ----- - ......-_+l.......
, " RIB 49.9
IATTENUATOR! " " 12
,..-----DB " 52 " S2
r-VOLTS---, SEC SEC
I CAL I
-40 01 -30.03 .1 -20 (REAR) CRE
C
OUT
RIS -60 RIB
15.8 -70 .0003-::"; " 3 tlO 15.8
-80 .0001 10 +20
ATTENUATOR ATI PART OF MODULE AI ABOVE
Figure 12C
3132 Input, Schematic
3-72
57/58
- -
INPUT SELFCTOR

I
I
I
I
I
I
I
I
I
I
I
1
I
I
'I
6200
II
I _

Al
200
r
A3
=
I
I
I
I
L_
r
A4
-
I
-,
RIO

Fill
10K
-=
C6
O.IUc
02
RI4
1100
AR

A7
:noo YI
ZSOKC
.... 101
I
I
I
I
I
rr
__________ 9J
_._-------
I
I
I
" 1,1
'"' TI
C 8 I I
250 i
I
I
I
_1
A4
3'OJ
C2
,OIUF !A6
68
112
;h!
RI2
I:AL I
l
500
OSC
ADJ
--t-.--J
I
1_0
'1'470
R:3
68C,
6
4
I
I
I
L
,
=
I
I
,
- - - - - - - - L 1 - -
IOIolHY
WHT- R 5 rv-YY' I
WHT-GAN
-.J
ATTNUATOR
AT!
- -
1
I
I
I
I
I
I
I
..J
--1
RI
200
rA6
L
p
F.-a... K
TI
II
I
I

, -,._--"
l
111:1 VAcl
.
CO
'i
.::;
;:
I
I
L
'RI
,"'2919"
-=
S7
(F"v"Tl
f1
"
R28
10K
C22
.IUF
L __
C21
.0IUF
CI8 CI9
.IUF .IUF
Rill
10K
l2
I. 0 "111 v
RIG
3900
RI7
1000
RI3
47K
RI4 S RI5 S CI4 -L -L- CI5 I R20 I I l R21 I R23 < R24< --L C20 I I R29
_. 18K: 10K: 4700: I 1000: 2200: 390: :.,UF I
Cil
.0IUF
CI3
,IUF
RI2
1100
CII
68
II
1.0 litH
-1"" - -fShECTIVlffl
I 1100HZ)
"""6"'"
4
IlIT)
SEE
C6
.0IUF
RIO
390
R9
3900
R7
10K
RB
2700
A4
C23
.IUF
CRI
IN277
R26
27K
R27
1000

10K
LE5_
-,
I
WH-VIO
MI
NOTES:
I. UNLESS OTHERWISE NOTED RESISTANCE VALUES AI
2. UNLESS OTHERWISE NOTED CAPACITANCE VALUES I
3. REFERENCE DESIGNATIONS ARE ASSIGNED STARTIN
MODULE TO DEFINE PART AND LOCATION PREFIX,
WITH MODULE IDENTIFICATION SUCH AS A2RI.
PREFIXED IN THIS MANNER.
4. Al l ROTARY SWITCHES ARE VIEWPl FROM KNOB E
EXTREME COUNTER CLOCKWISE POSITION, RE"ER
SCREENING AT EACH POSITION.
5. PANEL AND CHASSIS SCREENING DENOTED BY =
6. All TRANSISTORS ARE TYPE RC3710 EXCEPT WH
100 Hl SELECTIVITY THRU A4QB ARE TYPE
7. A4R33 AND A4R34 USED IN UNITS WITH 100Hl S
S7
(REAR j
I
I
I
I
I
10
I J I I 12 \
R WHT-YEl
ICAl lEVEl]
E4
R2
10K
[5
OUTPUT ICOUNTERI

E4o-fI B
I -=
I
-.J
E6
o
SEE FIGURE 13
IJJ
..
I
I
L
E6
--,
CIF;
('.2, }4
CI5
535
S3
8
9
10
o U
1.5-3.IUHY
E5
1I
C6
1500
E4
RII
41' 11
I
I
. I
I I -I"" ","'OR] I
1 W I
I I
I 2700 C7 CB I ITUNINGI

__-JL 47 8
L N470 ,CI2 CI3 C4 A CI7 I CI
_ _ _ _ _ _ 17-20 I'S I 33 11-150
_ _ _ _ _ _ I<OBO 2.2-34 NPO
___. J.
rA3
I ....-'IN
CIB
22UF
ELECTiVE LE
of

CIS
22UF
- I +It:-
OIAGRA
4
RI8
1M
Rill
1.2M
GRN
CR2
EI5 E9 CEil
IN277
l
RI5
RII
I
1500
1000
I , ,
CII
." '" .
. IUF
4700 IN277
Rt4
4700 I
RI6
3900
""IIVV
10
.0IUF
I
10

, 5
.' S'l
- - (REARl
II
i ,12
Yl

lISB
C4
2<:'0
R5
10K
YI =
2213.5
L SB
..J
AM L5B
e:r
55
(FRONT)
C3
.IUF
1I
I,OMHY
[7 E6 E'i
ORNIR IR
R4
60.4K
1%
VRI
IN950B
+ CI
IOUF
<;,
''',).:1
('
r A5
EI L2
,L
,"2
820
R-81<
I
I
I
Fi
I
I
LI
t
.-r---fIELECnVITY I
TI
1100HZ)
RI3
47K
CI2
.0IUF
CII I CI3
68 dUF
RI2 RI4 S
1100

-...,
E6
CIS -J,Ar CIF;
53S
-IBAND safffOR]
d
ITUNINGI
CI
CI7 11-150
33
NPO
J'
E4 E
WHT-YEI. R
R2 ICAL LEVEll
-=

l ICQUNTEffl

E2

I
I -=
SEE f'IGURE 13
I
I
E6 ES
o
L ..J
I
I
I
I
I
-,
R30
2700
R31
390
R28
10K
C22
.IUF
EI31 BLK
-+
_J
CI9
22UF
CI8
22 UF
CRI
1101277
C2 I
.0IUF
Rl6
27K
R27
1000
R23
10('\
CI6
'UF
RU
'11<
+
B
Rl')
10K
-,
I
WH-VIO
CI8 CI9
.IUF .IUF
RI9
1.2101
RI8
1M
SCHfMATIC
+
CI2
'UF
Ell
ell
.IUF

EIO
10
lUF
RI6
3900
filS
ISOO
l
LO..H.,
CR3
1101277
RI7
1000
CR2
IN277
--,
RII
'000
RIC S CI4 --l... --l...- CIS I R20 I I j R21 < I R23 < R24< ---.L- C20 I I R29 C24 --L. R32
10K: .IUF_L:IUF I 4700: I i 1000: 2200: 390: :.,UF I 33('0: .IUF: 68':>,
4
5
10

I
- - _/ SO;
(REAR)
II
'"6'''
i ,12
I
I
C23
.IUF
I
I
LES_
..J
57
Nil
(REARi
I NOTES:
,
I. UNLESS OTHERWISE NOTED RESISTANCE VALUES ARE IN OHMS, K:I,OOO.
I 2. UNLESS OTHERWISE NOTED CAPACITANCE VALUES ARE IN PICOFARADS (PF).
,
3. REFERENCE DESIGNATIONS ARE ASSIGNED STARTING WITH (II 0101 AT EACH
I MODULE TO DEFINE PART AND LOCATION PREFIX, THE REFERENOE DESIGNATif
I WITH MODULE IDENTIFICATION SUCH AS A2RI. CHASSIS COMPONE.NTS ARE /lOT
I PREFIXED IN THIS MANNER.
4. ALL ROTARY SWITCHES ARE FROM KNOB END AND ARE SHOW" IN THE
EXTREME COUNTER CLOCKWISE POSITION. RE"ER TO INDIVIDUALS FO'! THE
SCREENING AT EACH POSITION.
S. PANEL AND CHASSIS SCREENING DENOTED BY BOXES.
6. ALL TRANSISTORS ARE TYPE RC3710 EXCEPT WHEN NOTED. UNITS WITH
I
100 Hl SELECTIVITY A.401 THRU A408 ARE TYPE 21014124,
I
7. A4R33 AND A4R34 USED IN UNITS WITH 100Hl SELECTIVITY, IF REOUIRED.
I
..
[HEADSET]
LSI
LECTIVE LEVELME DI AM,31?IB, 6
11
--;-
I
R
I
A3
---"4-"-;--::--
I 1000 41 I.OMHY
I
I
II
I
1 LOCAL OSC
- SEE A3 ON SELECTIVE LEVEL METER
""""'o.pIUF
SCHEMATIC DIAGRAM, FIG. 12
1
I

I
I I
I ___J
1
I


--------------,
I
LI
t
lMHY RIO
I
180
RI2
2200
R6 R9 C3
820 1500
R2
0.22UF
{
03
{
04
L2 L3 RC3710 18K
+ I IE--
I
6 6

II
I I J3 7 06 01 02 I
CI2
RC37W
I
ICOUNTEI RC3710 R8 10UF
RI 1000 II 90--'61
I
6
5
.................. +1/
270
1,

{
:

YE + I RI4 RII RI7 1
C5 C9 620 39K I lOOK CI .----4
180 180
I
O.oIUF
II
1\ +
C6 ......l-C7 ---L.- CIO 3 I 14 !
/"'T"'250
RI3
""""'g70 :::T'IOUF 250"""'"
2700 270 10K
ICI R3 R4 R5 ---L.- C2 R7
I
CA3028A 2200 820 3900 1500
I
T.l
UF
....L..
I
L4
I
IMHY
I I
--;
I. UNLESS OTHERWISE NOTED RESISTANCE
VALUES ARE IN OHMS. K: 1000.
I
RI8 05
15K RC3710 2. UNLESS OTHERWISE NOTED CAPACITANCE I
{
VALUES ARE IN PF. PICOFARAD.
I
CI5 -.l
YI 3001"T'
2215
I
I
KHz
RI9 I R20 CI8
S4700 O.oIUF
I
I
03
1
CI4 1
22K
L5 L;;- )f------J --'- CI.
5.5-18 1
30
1
200
47UH Tf,'b . JO.IUF
1
I
_
__J

------
I
Figure 13
Counter Output Module, Schematic
I
611
3-72
-