DESIGN CRITERIA
I. DEAD LOADS 5"-CHB 4"-CHB Slab (130-mm thick) Slab (100-mm thick) Tiles Ceiling Roof Sheet (Ga. 24) Steel Deck at 4th Floor (Ga. 20) Concrete Steel Soil 2.45 2.20 3.07 2.36 0.50 0.20 0.10 0.12 kPa kPa kPa kPa kPa kPa kPa kPa
II. LIVE LOADS School Stairs Roof 1.90 kPa 4.80 kPa 0.60 kPa
III. WIND LOADS It is assumed that Earthquake Loads shall govern. Therefore Wind Loads are neglected.
IV. EARTHQUAKE LOADS Zone factor Z = Importance factor I = Moment-Resisting Frame constant Rw = Soil coefficient S = Ct for Steel moment-resisting frames = 0.4 1.00 12.0 1.0 0.085
Concrete (Factored) 201 202 203 204 205 206 207 208 209 Steel 101 102 103 104 105 106 107 108 109 110 DL
Where: DL - Dead Load LL - Live Load ELX - Earhtquake Load along the X-Direction ELZ - Earhtquake Load along the Z-Direction
VI. FOUNDATION Safe bearing pressure (qs) of 150 kPa (3,000 psf) may be adopted for analysis considering dead and live loads. This may be increased to 200 kPa (4,000 psf) for analysis considering transient loads such as wind and earthquake.
VII.MATERIAL STRESSES Specified concrete strength f'c = Concrete modulus of elasticity Ec = 4700 (f'c) Yield strength for steel Fy = Yield strength for reinforcing bars fy = Welding electrode Modulus of elasticity for steel E =
1/2
28 MPa (28 days) 24870 MPa 248 MPa (For structural shapes) 248 MPa (A325 anchor bolts) 276 MPa (For 16-mm f and below) 414 MPa (For 20-mm f and below) E70XXX 200000 MPa
VIII. DESIGN REFERENCES National Structure Code of the Philippines (4th Edition) Uniform Building Code (1997) American Institute of Steel Construction (9th Edition) American Concrete Institute (318M-05) Geotechnical Investigation Report (Dated: March 2010)
STEEL DESIGN
CONCRETE DESIGN