Вы находитесь на странице: 1из 47

ANGEL LAZARO & ASSOCIATES INTERNATIONAL

Consulting Engineers and Architects 160 Panay Ave., Cor EDSA, Quezon City 1103 Philippines
Tel. No. 924-1911 924-1865 924-1879 924-1931 Fax No. (632) 924-1887

Project Title: Consulting Services for the Detailed Engineering (Structural) Investigation of the Manila Cathedral Contractor : Client: THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Calc. Title: BEAM SCHEDULE DATA INPUT Drawing Ref. Dwg. No. AS BUILT PLAN DRAWING Sht. No. S-5 TO S-6 Calc. by ARNEL SINCONIEGUE

Date : Chk'd. by : RHONDA RAPIRAP Date : Appr'd. by : ANGEL L. LAZARO III, Ph. D. Date :

Material Properties Concrete Strength (f'c) Steel Yield Strengthfor Main Bars (fy) Steel Yield Strength for Stirrup Bars (fy) 20.71 MPa 413.00 MPa 413.00 MPa 3,000 psi 59,904 psi 59,904 psi

All dimensions are in millimeters unless otherwise indicated

Beam

Beam Mark

Dimensions Total Concrete Effective Width (b) At left support Depth (h) Cover (d') Depth (d) Number Diameter

Flexural Reinforcement At Midspan Number Diameter

At Right Support Number Diameter Diameter

Shear Reinforcement At Left Support At Right Support At left support First Next Maximum Diameter First Next Maximum Clear Total Spacing Spacing Spacing Spacing Spacimg Spacing Spacing Number between Layers Bars of Bars

Crack Control At Midspan Clear Total Spacing Number between Layers Bars of Bars

At Right Support Clear Total Spacing Number between Layers Bars of Bars

2nd FLR 2nd FLR 2nd FLR 2nd FLR

2B-1 2B-2 2B-3 2B-4

610 500 500 700

40 40 40 40

570 460 460 660

285 360 350 350

3 3 3 4

25 16 20 20

3 5 6 6

25 16 20 20

3 3 3 4

25 16 20 20

10 10 10 10

100 300 300 300

150 300 300 300

250 300 300 300

10 10 10 10

100 300 300 300

150 300 300 300

250 300 300 300

220 116 105 63

1 1 1 1

220 50 30 30

1 1 1 1

220 116 105 63

1 1 1 1

Terrace Terrace Terrace Terrace

3B-1 3B-4 3B-2 3B-3

750 600 500 500

40 40 40 40

710 560 460 460

350 350 500 350

5 5 4 3

20 20 16 20

7 8 4 6

20 20 16 20

5 5 4 3

20 20 16 20

10 10 10 10

300 300 300 300

300 300 300 300.0

300 300 300 300.0

10 10 10 10

300 300 300 300

300 300 300 300.0

300 300 300 300.0

43 43 119 105

1 1 1 1

22 16 119 30

1 1 1 1

43 43 119 105

1 1 1 1

FIG. 2.4b -- SCHEDULE OF BEAMS

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects 160 Panay Ave., Cor EDSA, Quezon City 1103 Philippines
Tel. No. 924-1911 924-1865 924-1879 924-1931 Fax No. (632) 924-1887

Project Title: Contractor : Client: Calc. Title:

Consulting Services for the Detailed Engineering (Structural) Investigation of the Manila Cathedral THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA SUMMARY OF RESULT FOR MOMENT AND SHEAR CAPACITY-DEMAND ANALYSIS Calc. by ARNEL SINCONIEGUE

Date : Chk'd. by : RHONDA RAPIRAP Date : Appr'd. by : ANGEL L. LAZARO III, Ph. D. Date :

Drawing Ref. Dwg. No. AS BUILT PLAN DRAWING Sht. No. S-5 TO S-6

Beam

Beam Mark

Moment Analysis At Left Support At Midspan Capacity Demand C/D Ratio Capacity Demand C/D Ratio kN-m kN-m kN-m kN-m

Shear Analysis At Right Support Capacity Demand C/D Ratio kN-m kN-m Remarks At Left Support Capacity Demand C/D Ratio Shear kN kN Reinforcement Needed? Minimum Stirrup Area Maximum Spacing At Right Support Capacity Demand C/D Ratio Shear kN kN Reinforcement needed? Minimum Stirrup Area Maximum Spacing

Crack Control

2nd FLR 2nd FLR 2nd FLR 2nd FLR 2nd FLR

2B-1 2B-2 2B-3 G-1 2B-4

278.83 98.73 150.08 444.34 288.61

150 170.48 115.7 587.62 97.64

1.86 0.58 1.30 0.76 2.96

278.83 159.65 278.04 728.57 418.17

250 60.48 5.1 308.49 23.21

1.12 2.64 54.52 2.36 18.02

278.83 98.73 150.08 444.34 288.61

174.00 168.65 29.71 319.48 184.78

1.60 0.59 5.05 1.39 1.56

Compliant Compliant Compliant Compliant Compliant

301.08 163.14 160.17 272.37 229.82

200.00 104.39 75.86 289.19 94.14

1.51 1.56 2.11 0.94 2.44

Needed Needed Not Needed Needed Not Needed

Compliant Compliant Compliant Non-Compliant Compliant Non-Compliant Non-Compliant Compliant Compliant Compliant

284.35 163.14 248.75 272.37 229.82

250.00 103.86 37.64 163.47 125.64

1.14 1.57 6.61 1.67 1.83

Needed Needed Not Needed Needed Not Needed

Compliant Compliant Compliant Compliant Compliant

Compliant Non-Compliant Non-Compliant Compliant Compliant

Non-Compliant Non-Compliant Non-Compliant Non-Compliant Compliant

Terrace Terrace Terrace Terrace

3B-1 3B-4 3B-2 3B-3

383.81 296.23 131.87 150.08

273.74 262.23 195.61 145.63

1.40 1.13 0.67 1.03

520.13 444.47 131.87 278.04

133.51 141.37 110.96 108.115

3.90 3.14 1.19 2.57

383.81 296.23 131.87 150.08

163.57 0.00 0.00 223.25

2.35

0.67

Compliant Compliant Compliant Compliant

247.23 194.99 204.66 160.17

153.90 140.09 109.22 106.34

1.61 1.39 1.87 1.51

Needed Needed Needed Needed

Compliant Compliant Compliant Non-Compliant Non-Compliant Non-Compliant Compliant Non-Compliant

247.23 194.99 204.66 248.75

20.71 70.63 60.31 123.59

11.94 2.76 3.39 2.01

Not Needed Not Needed Not Needed Not Needed

Compliant Compliant Compliant Compliant Non-Compliant Compliant Non-Compliant Non-Compliant Non-Compliant Compliant Non-Compliant Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 2B-1 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b1 = Capacity Reduction Factor f = 285 610 40 570 20.71 413.00 25 3 1,472.63 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00907 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 447.55 550.68 < < 1,472.63 Compliant 1,472.63 Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

608,194 121.21 509.40 309.81 278.83

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2 ) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

220 1

247.80 125.00 11,875.00 22,435.68 95.00 < < 25000.00 Compliant 245.00 Non-Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b1 = Capacity Reduction Factor f = 285 610 40 570 20.71 413.00 25 3 1,472.63 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00907 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 447.55 550.68 < < 1,472.63 1,472.63 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

608,194 121.21 509.40 309.81 278.83

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

220 1

247.80 125.00 11,875.00 22,435.68 95.00 < < 25000.00 Compliant 245.00 Non-Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b1 = Capacity Reduction Factor f = 285 610 40 570 20.71 413.00 25 3 1,472.63 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00907 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 447.55 550.68 < < 1,472.63 Compliant 1,472.63 Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

608,194 121.21 509.40 309.81 278.83

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

220 1

247.80 125.00 11,875.00 22,435.68 95.00 < < 25000.00 Compliant 245.00 Non-Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 2B-1 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 285 610 40 570 20.71 413.00 10 175 157.08 100 0.9 200.00

411.4.1 411.6.6.2

123.22 211.30 334.53 301.08

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 142.5 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 610 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = 200.00 Vd/2 = 150.54 Needed If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

411.6.5.3

40.25 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = 200.0 f*Vc = 110.90 Vs = (Vu - f*Vc)/f = 99.0 (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Compliant 246.4 285 250

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 285 610 40 570 20.714 413.00 10 175 157 100 0.85 250.00

411.4.1 411.6.6.2

123.22 211.30 334.53 284.35

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 142.5 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 610 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = 250.00 Vd/2 = 142.17 Needed If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

411.6.5.3

40.25 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = 250.00 f*Vc = 104.74 Vs = (Vu - f*Vc)/f = 170.89 (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Compliant 246.4 285 250

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 2B-2 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00364 < 0.01610 Compliant 360 500 40 460 20.71 413.00 16 3 603.19 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 456.22 561.36 < < 603.19 603.19 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

249,116 39.30 440.35 109.70 98.73

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

116 1

247.80 116.00 13,920.00 23,074.04 120.00 < < 25000.00 Compliant 132.00 Non-Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number 2 As = n*[p*(db) /4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00607 < 0.01610 Compliant 360 500 40 460 20.71 413.00 16 5 1,005.31 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 456.22 561.36 < < 1,005.31 1,005.31 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

415,194 65.50 427.25 177.39 159.65

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw /N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

50 1

247.80 116.00 8,352.00 19,461.40 72.00 < > 25000.00 Compliant 66.00 Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number 2 As = n*[p*(db) /4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00364 < 0.01610 Compliant 360 500 40 460 20.71 413.00 16 3 603.19 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 456.22 561.36 < < 603.19 603.19 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

249,116 39.30 440.35 109.70 98.73

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

116 1

247.80 116.00 13,920.00 23,074.04 120.00 < < 25000.00 Compliant 132.00 Non-Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 2B-2 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 360 500 40 460 20.714 413.00 10 450 157.08 300 0.85 104.39

411.4.1 411.6.6.2

125.61 66.32 191.93 163.14

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 180 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 500 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = 104.39 Vd/2 = 81.57 Needed If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

411.6.5.3

130.75 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = 104.39 f*Vc = 106.77 Vs = (Vu - f*Vc)/f = -2.80 (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 251.2 230 300

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 360 500 40 460 20.714 413.00 10 450 157.08 300 0.85 103.86

411.4.1 411.6.6.2

125.61 66.32 191.93 163.14

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 180 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 500 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Needed 103.86 81.57

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

130.75 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 103.86 106.77 -3.43 251.2 230 250

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK:

2B-3 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00585 < 0.01610 Compliant 350 500 40 460 20.71 413.00 20 3 942.48 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 443.55 545.76 < < 942.48 942.48 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

389,244 63.17 428.42 166.76 150.08

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

105 1

247.80 120.00 14,000.00 23,380.89 116.67 < < 25000.00 Compliant 125.00 Non-Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.01171 < 0.01610 Compliant 350 500 40 460 20.71 413.00 20 6 1,884.96 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 443.55 545.76 < < 1,884.96 1,884.96 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

778,488 126.33 396.83 308.93 278.04

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

30 1

247.80 120.00 7,000.00 18,557.43 58.33 < > 25000.00 Compliant 50.00 Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00585 < 0.01610 Compliant 350 500 40 460 20.71 413.00 20 3 942.48 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 443.55 545.76 < < 942.48 942.48 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

389,244 63.17 428.42 166.76 150.08

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

105 1

247.80 120.00 14,000.00 23,380.89 116.67 < < 25000.00 Compliant 125.00 Non-Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK:

2B-3 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 500 40 460 20.71 413.00 10 450 157.08 300 0.85 75.86

411.4.1 411.6.6.2

122.12 66.32 188.44 160.17

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 500 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = 75.86 Vd/2 = 80.09 Not Needed If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

411.6.5.3

127.12 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = 75.86 f*Vc = 103.81 Vs = (Vu - f*Vc)/f = -32.88 (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 244.25 230 300

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 500 40 460 20.714 413.00 10 175 157.08 250 0.85 37.64

411.4.1 411.6.6.2

122.12 170.53 292.65 248.75

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 500 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Not Needed 37.64 124.38

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

49.44 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = 37.64 f*Vc = 103.81 Vs = (Vu - f*Vc)/f = -77.84 (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 244.25 230 300

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : ROMAN CATHOLIC ARCHDIOCESE OF MANILA THE Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: G-1 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00661 < 0.01610 Compliant 450 700 40 660 20.71 413.00 25 4 1,963.50 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 818.23 1,006.78 < < 1,963.50 1,963.50 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

810,926 102.35 608.82 493.71 444.34

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

90 1

247.80 125.00 14,062.50 23,736.43 112.50 < < 25000.00 Compliant 115.00 Non-Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number 2 As = n*[p*(db) /4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.01157 < 0.01610 Compliant 450 700 40 660 20.71 413.00 25 7 3,436.13 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 818.23 1,006.78 < < 3,436.13 3,436.13 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

1,419,120 179.11 570.44 809.53 728.57

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

33 1

247.80 125.00 8,035.71 19,697.12 64.29 < > 25000.00 Compliant 57.50 Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number 2 As = n*[p*(db) /4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00661 < 0.01610 Compliant 450 700 40 660 20.71 413.00 25 4 1,963.50 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 818.23 1,006.78 < < 1,963.50 1,963.50 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

810,926 102.35 608.82 493.71 444.34

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

90 1

247.80 125.00 14,062.50 23,736.43 112.50 < < 25000.00 Compliant 115.00 Non-Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : 0 Client : Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: G-1 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 450 700 40 660 20.714 413.00 10 450 157.08 300 0.85 289.19

411.4.1 411.6.6.2

225.29 95.15 320.43 272.37

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 225 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 700 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Needed 289.19 136.18

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Non-Compliant

163.44 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Compliant 289.19 191.49 114.94 450.57 330 300

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 450 700 40 660 20.714 413.00 10 450 157.08 300 0.85 163.47

411.4.1 411.6.6.2

225.29 95.15 320.43 272.37

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 225 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 700 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Needed 163.47 136.18

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Non-Compliant

163.44 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Compliant 163.47 191.49 -32.97 450.57 330 300

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : ROMAN CATHOLIC ARCHDIOCESE OF MANILA THE Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 2B-4 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00544 < 0.01610 Compliant 350 700 40 660 20.71 413.00 20 4 1,256.64 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 636.40 783.05 < < 1,256.64 1,256.64 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

518,992 84.22 617.89 320.68 288.61

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

63 1

247.80 120.00 10,500.00 21,242.95 87.50 < > 25000.00 Compliant 83.30 Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00816 < 0.01610 Compliant 350 700 40 660 20.71 413.00 20 6 1,884.96 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 636.40 783.05 < < 1,884.96 1,884.96 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

778,488 126.33 596.83 464.63 418.17

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

30 1

247.80 120.00 7,000.00 18,557.43 58.33 < > 25000.00 Compliant 50.00 Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00544 < 0.01610 Compliant 350 700 40 660 20.71 413.00 20 4 1,256.64 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 636.40 783.05 < < 1,256.64 1,256.64 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

518,992 84.22 617.89 320.68 288.61

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

63 1

247.80 120.00 10,500.00 21,242.95 87.50 < > 25000.00 Compliant 83.30 Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : ROMAN CATHOLIC ARCHDIOCESE OF MANILA THE Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 2B-4 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 700 40 660 20.714 413.00 10 450 157.08 300 0.85 94.14 450 300

411.4.1 411.6.6.2

175.22 95.15 270.37 229.82

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 700 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Not Needed 94.14 114.91

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

127.12 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Compliant 94.14 148.94 -64.47 350.44 330 0

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 700 40 660 20.714 413.00 10 450 157.08 300 0.85 125.64

450 300

411.4.1 411.6.6.2

175.22 95.15 270.37 229.82

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 700 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Needed 125.64 114.91

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

127.12 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Compliant 125.64 148.94 -27.41 350.44 330 0

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : ROMAN CATHOLIC ARCHDIOCESE OF MANILA THE Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by :ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 3B-1 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = 350 750 40 710 20.71 413.00 20 5 1,570.80 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00632 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 684.61 842.37 < < 1,570.80 1,570.80 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

648,740 105.28 657.36 426.46 383.81

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

43 1

247.80 120.00 8,400.00 19,720.21 70.00 < > 25000.00 Compliant 62.50 Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = 350 750 40 710 20.71 413.00 20 7 2,199.12 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00885 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 684.61 842.37 < < 2,199.12 2,199.12 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

908,237 147.39 636.31 577.92 520.13

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

22 1

247.80 120.00 6,000.00 17,627.96 50.00 < > 25000.00 Compliant 41.70 Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = 350 750 40 710 20.71 413.00 20 5 1,570.80 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00632 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 684.61 842.37 < < 1,570.80 1,570.80 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

648,740 105.28 657.36 426.46 383.81

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

43 1

247.80 120.00 8,400.00 19,720.21 70.00 < > 25000.00 Compliant 62.50 Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : 0 Client : Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by :ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 3B-1 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 750 40 710 20.714 413.00 10 450 157.08 300 0.85 153.90

450 300

411.4.1 411.6.6.2

188.50 102.36 290.85 247.23

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 750 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Needed 153.90 123.61

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

127.12 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Compliant 153.90 160.22 -7.44 376.99 355 300

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 750 40 710 20.714 413.00 10 450 157.08 300 0.85 20.71

450 300

411.4.1 411.6.6.2

188.50 102.36 290.85 247.23

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 750 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Not Needed 20.71 123.61

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

127.12 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Compliant 20.71 160.22 -164.13 376.99 355 300

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : ROMAN CATHOLIC ARCHDIOCESE OF MANILA THE Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 3B-4 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = 350 600 40 560 20.71 413.00 20 5 1,570.80 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00801 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 539.98 664.41 < < 1,570.80 1,570.80 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

648,740 105.28 507.36 329.15 296.23

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

43 1

247.80 120.00 8,400.00 19,720.21 70.00 < > 25000.00 Compliant 62.50 Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = 350 600 40 560 20.71 413.00 20 8 2,513.28 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.01282 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 539.98 664.41 < < 2,513.28 2,513.28 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = 1,037,985 Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = 168.44 Calculate Moment Arm z = d - (a/2) = 475.78 Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = 493.85 Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn = 444.47

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

16 1

247.80 120.00 5,250.00 16,860.54 43.75 < > 25000.00 Compliant 35.70 Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = 350 600 40 560 20.71 413.00 20 5 1,570.80 0.85 0.90

Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00801 < 0.01610 Compliant

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 539.98 664.41 < < 1,570.80 1,570.80 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

648,740 105.28 507.36 329.15 296.23

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

43 1

247.80 120.00 8,400.00 19,720.21 70.00 < > 25000.00 Compliant 62.50 Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : 0 Client : Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 3B-4 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 600 40 560 20.714 413.00 10 450 157.08 300 0.85 140.09

450 300

411.4.1 411.6.6.2

148.67 80.73 229.41 194.99

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 600 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Needed 140.09 97.50

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

127.12 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 140.09 126.37 16.14 297.35 280 300

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 600 40 560 20.714 413.00 10 450 157.08 300 0.85 70.63

450 300

411.4.1 411.6.6.2

148.67 80.73 229.41 194.99

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 600 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Not Needed 70.63 97.50

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

127.12 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 70.63 126.37 -65.58 297.35 280 300

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 3B-2 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00350 < 0.01610 Compliant 500 500 40 460 20.71 413.00 16 4 804.25 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 633.65 779.66 < < 804.25 804.25 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

332,155 37.73 441.13 146.53 131.87

CRACK CONTROL ACI 318-99 & NSCP 410.7.3Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

119 1

247.80 116.00 14,500.00 23,390.17 125.00 < < 25000.00 Compliant 134.70 Non-Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00350 < 0.01610 Compliant 500 500 40 460 20.71 413.00 16 4 804.25 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 633.65 779.66 < < 804.25 804.25 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

332,155 37.73 441.13 146.53 131.87

CRACK CONTROL ACI 318-99 & NSCP 410.7.3Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

119 1

247.80 116.00 14,500.0 23,390.17 125.00 < < 25000.00 Compliant 134.70 Non-Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00350 < 0.01610 Compliant 500 500 40 460 20.71 413.00 16 4 804.25 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 633.65 779.66 < < 804.25 804.25 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

332,155 37.73 441.13 146.53 131.87

CRACK CONTROL ACI 318-99 & NSCP 410.7.3Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

119 1

247.80 116.00 14,500.00 23,390.17 125.00 < < 25000.00 Compliant 134.70 Non-Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK: 3B-2 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section s cri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 500 500 40 460 20.714 413.00 10 450 157.08 300 0.85 109.22

450 300

411.4.1 411.6.6.2

174.46 66.32 240.78 204.66

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 250 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 500 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Needed 109.22 102.33

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Non-Compliant

181.60 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 109.22 148.29 -45.97 348.93 230 300

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section s cri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 500 500 40 460 20.714 413.00 10 450 157.08 300 0.85 60.31

450 300

411.4.1 411.6.6.2

174.46 66.32 240.78 204.66

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 250 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 500 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Not Needed 60.31 102.33

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Non-Compliant

181.60 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = f*Vc = Vs = (Vu - f*Vc)/f = (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 60.31 148.29 -103.51 348.93 230 300

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM BENDING OR FLEXURAL CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK:

3B-3 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00585 < 0.01610 Compliant 350 500 40 460 20.71 413.00 20 3 942.48 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 443.55 545.76 < < 942.48 942.48 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

389,244 63.17 428.42 166.76 150.08

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

105 1

247.80 120.00 14,000.00 23,380.89 116.67 < < 25000.00 Compliant 125.00 Non-Compliant

AT MIDSPAN Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.01171 < 0.01610 Compliant 350 500 40 460 20.71 413.00 20 6 1,884.96 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 443.55 545.76 < < 1,884.96 1,884.96 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

778,488 126.33 396.83 308.93 278.04

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

30 1

247.80 120.00 7,000.00 18,557.43 58.33 < > 25000.00 Compliant 50.00 Compliant

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength (MPa) Steel Yield Stress (MPa) Steel Reinforcement Diameter db Number As = n*[p*(db)2/4] 410.3.7.3 409.4.2.1 410.4.3 Compressive Block depth b 1 = Capacity Reduction Factor f = Check if beam conforms to maximum reinforcement requirement rb = 0.85*b1*(f'c/fy)*[600/(600+fy)] = 0.75*rb = actual r = As/(b*d) = 0.02146 0.01610 0.00585 < 0.01610 Compliant 350 500 40 460 20.71 413.00 20 3 942.48 0.85 0.90

If beam is overreinforced, analyze using the maximum reinforcement allowed Ignore succeeding results of this worksheet 410.6.1 Check if beam comforms to minimum reinforcement requirement (NSCP 410.6.1) (As)min = [sqrt(f'c)/(4*fy)]*b*d = (As)min = (1.4/fy)*b*d = 443.55 545.76 < < 942.48 942.48 Compliant Compliant

If beam is Non-Compliant, place the words "Less Than Minimum" in Remarks Column of Results Ignore succeeding results of this worksheet Calculate Steel Tensile Force Nt = As*fy = Calculate Depth of Concrete Block a = Nt/(0.85*f'c*b) = Calculate Moment Arm z = d - (a/2) = Calculate Nominal Moment (kiloNewton-meters): Mn = Nt*z/1000 = Calculate Design Moment Capacity (kiloNewton-meters): Mu = 0.90*Mn =

389,244 63.17 428.42 166.76 150.08

CRACK CONTROL ACI 318-99 & NSCP 410.7.3 Distribution of Flexural Reinforcing, Clear Spacing between Bars Total Number Layer of Bars (Nb) Calculate stress in reinforcement fs = 0.60*fy = Total height of concrete surround in reinforcement dg = 2(Cc + ds + db/2) = Effective tension area of concrete surround, Ae = dg*bw / N Limiting distribution of flexural reinforcement z = fs*[(dg/2)*Ae]^(1/3) Maximum spacing for crack control s = z / (2*fs dc)

105 1

247.80 120.00 14,000.00 23,380.89 116.67 < < 25000.00 Compliant 125.00 Non-Compliant

ANGEL LAZARO & ASSOCIATES INTERNATIONAL


Consulting Engineers and Architects
160 Panay Ave., Cor EDSA, Quezon City. 1103 Philippines
Tel. No. 924-1911, 924-1865, 924-1879 & 924-1931

Date : Client : THE ROMAN CATHOLIC ARCHDIOCESE OF MANILA Subject : BEAM SHEAR CAPACITY WORKSHEET

Calc. by : ARNEL SINCONIEGUE Chk'd. by : RHONDA RAPIRAP Appr'd. by : ANGEL L. LAZARO III, Ph. D.

BEAM MARK:

3B-3 All dimensions are in Newtons or millimeters unless otherwise indicated

AT LEFT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 500 40 460 20.71 413.00 10 450 157.08 300 0.85 106.34

411.4.1 411.6.6.2

122.12 66.32 188.44 160.17

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 500 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = 106.34 Vd/2 = 80.09 Needed If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

411.6.5.3

127.12 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = 106.34 f*Vc = 103.81 Vs = (Vu - f*Vc)/f = 2.98 (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 244.25 230 300

AT RIGHT SUPPORT Width Total Depth Concrete Cover Effective Depth Concrete Compressive Strength Steel Yield Strength Shear Reinforcement Diameter Spacing at critical section scri Area Av Maximum spacing Strength Reduction Factor f = Shear Demand Vu (kiloNewtons) = Calculate Shear Capacity of Section, kiloNewtons: Shear Strength Provided by Concrete Vc = (1/6)*sqrt(f'c)*b*d = Shear Strength Provided by Shear Reinforcement Vs = (Av*fy*d)/scri = Shear Capacity of Section Vn = Vc + Vs = Design Shear Capacity Vd = f*Vn = 350 500 40 460 20.714 413.00 10 175 157.08 250 0.85 123.59

411.4.1 411.6.6.2

122.12 170.53 292.65 248.75

411.6.5.1

Determine if shear reinforcement is needed Shear reinforcement not needed if total depth h is not more than the greatest of the following: 1. 250 mm 250 2. 0.5*b = 175 3. 2.5*(flange thickness) = Not applicable, not T-beam Greatest of above = 250 Total depth h = 500 May be Needed Shear reinforcement not needed if Vu < Vd/2? Vu = Vd/2 = Not Needed 123.59 124.38

411.6.5.3

If shear reinforcement is needed, determine minimum area (Av)min = b*s/(3*fy) = (Av)actual) = Compliant

49.44 157.08

411.6.4.1 411.6.4.3

If shear reinforcement is needed, determine maximum spacing If Vs > (1/3)*sqrt(f'c)*b*d, maximum s = d/4, otherwise maximum s = d/2 Vu = 123.59 f*Vc = 103.81 Vs = (Vu - f*Vc)/f = 23.28 (1/3)*sqrt(f'c)*b*d = Maximum Spacing = d/2 d/2 = maximum spacing = Non-Compliant 244.25 230 300

Вам также может понравиться