About This Chapter
The aim of routine maintenance is to find and remove hidden fault causes in time before the equipment becomes faulty and services are affected. Simply, nip in the bud. 1.1 Routine Maintenance Items Routine maintenance items are classified into three categories, routine maintenance items carried out on an NM system, field maintenance items for indoor equipment, and field maintenance items for outdoor equipment. 1.2 Guide to Routine Maintenance on an NM System This guide provides operation methods for routine maintenance on a Web LCT. For the methods using a T2000, refer to the T2000 online help. 1.3 Guide to Field IDU Maintenance This guide describes how to carry out routine maintenance for the IDU and the equipment room where the IDU is installed. 1.4 Guide to Field Maintenance of Outdoor Equipment This guide describes how to carry out routine maintenance on site for outdoor equipment.
Issue 06 (2007-12-30)
1-1
One week
Half year
Only for the case that the equipment applies the 1+1 configuration Within the 1+1 HSB switching time (< 500 ms), protection services will be interrupted. Hence, carry out a 1+1 HSB switching operation at the time when the traffic volume is small.
Issue 06 (2007-12-30)
Maintenance Item Testing the Orderwire Phone Checking the Equipment Room
Refer To 1.3.2 Testing the Orderwire Phone 1.3.3 Checking the Equipment Room
Remarks Only for the case that the equipment is equipped with the orderwire phone Only for the case that the equipment is installed indoors
Two months
NOTE
a: When the IDU 620 is installed in an outdoor dust-proof cabinet or the IDU is not installed with an air filter, there is no need to clean the air filter.
Issue 06 (2007-12-30)
1-3
Prerequisite
l l
The Web LCT has a normal communication with the NE. The NE user has the "monitor level" authority or higher.
Procedure
Step 1 Select the NE from the object tree in the NE Explorer. Click Step 2 Check the Auto Refresh check box. Step 3 Browse the displayed alarms. Step 4 If there are newly generated alarms after the last maintenance, notify the fault clearing personnel in a timely manner. For alarm clearing methods, refer to A Alarm Reference. Step 5 Optional: Click Save as, Save the current alarms to a file. ----End on the toolbar.
Prerequisite
l l
The Web LCT has a normal communication with the NE. The NE user has the "monitor level" authority or higher.
Procedure
Step 1 Select the NE from the object tree in the NE Explorer. Choose Alarm > Browse Abnormal Events from the function tree. Step 2 Check the Prompt New Event Occurs check box. Step 3 Browse the displayed abnormal events. Step 4 Optional: Click Save as, Save the current abnormal events to a file. ----End
Prerequisite
l l
The Web LCT has a normal communication with the NE. The NE user has the "monitor level" authority or higher.
Procedure
Step 1 Select the board whose performance events you want to query from the object tree in the NE Explorer. Choose Performance > Current Performance from the function tree. Step 2 Set the options for querying performance events. Set as follows:
l l l l l
Set the Monitor Object Filter Condition to All. Set the Monitor Period Settings to 24-Hour. In the Count, select all available performance events. In the Gauge, select all available performance events. In the Options, select only Maximum/Minimum Value.
Step 3 Click Query. Step 4 Browse the displayed performance events. In normal situations, there should be no bit error performance events. The number of pointer justification events should be less than six per day. For the gauge performance events like board temperature, there should be no obvious change when compared with the record values. Step 5 Optional: Click Save as, Save the current performance events to a file. Step 6 Repeat Step 1 to Step 5 to browse the performance events of other boards. ----End
Prerequisite
l l
The Web LCT has a normal communication with the NE. The NE user has the "maintenance level" authority or higher.
Precautions
l
As the manual switching mode is used to carry out the IF 1+1 switching and all manual switching operations belong to the equipment switching (HSB switching), protection
Huawei Technologies Proprietary 1-5
Issue 06 (2007-12-30)
services will be interrupted within the switching time (<1 s). Hence, carry out a switching operation at the time when the traffic volume is small.
l
Before a switching operation, make sure that the standby equipment is in normal conditions. If a switching operation fails, contact Huawei engineers in time.
Procedure
Step 1 Select the NE from the object tree in the NE Explorer. Choose Configuration > IF 1+1 Protection from the function tree. Step 2 In the Slot Mapping Relation dialog box, select the IF board and right-click. In the displayed menu, click Manual to Standby. Step 3 After the equipment operates normally for a period of time, query the alarms and performance events of services. There should be no new alarm or performance event. Step 4 Repeat Step 1. Step 5 In the Slot Mapping Relation dialog box, select the IF board and right-click. In the displayed menu, click Clear. Step 6 After the equipment operates normally for a period of time, query the alarms and performance events of services. There should be no new alarm or performance event. ----End
Prerequisite
None.
Procedure
Step 1 Loosen the captive screws on the panel of the fan box. Step 2 Move the cables away from the front of the panel of the fan box. Step 3 Draw out the air filter at the left side.
1-6 Huawei Technologies Proprietary Issue 06 (2007-12-30)
Step 4 Use an air blower or a clean brush to clean the air filter. Step 5 After the cleaning, insert the air filter back to its original position. Step 6 Tighten the screws on the panel of the fan box. ----End
Prerequisite
l l
The NE has been correctly installed with an orderwire phone. The orderwire data has been correctly configured.
Procedure
Step 1 Check the status of the orderwire phone. The orderwire phone should meet the following requirements.
l l
The ring current switch "RING" is set to "ON". The dialing mode switch is set to "T", that is, the dual tone multi-frequency mode.
Step 2 Make orderwire calls. 1. Hook-off the orderwire phone and press the "TALK" button. The red indicator on the front of phone set should be lit and you can hear the dialing prompt tone. 2. Make orderwire calls to other NEs. The calls should be normal and the voice should be clear. Step 3 Receive orderwire calls. 1.
Issue 06 (2007-12-30)
The maintenance personnel of other NEs make calls to the orderwire phone.
Huawei Technologies Proprietary 1-7
The phone should ring. 2. Hook-off the phone, press the "TALK" button, and have a conversation. The red indicator on the front of phone set should be lit. The call should be normal and the voice should be clear. ----End
Prerequisite
None.
Procedure
Step 1 Record the thermometer reading in the equipment room. The normal temperature should be between -5 and 45. Step 2 Record the reading of the humidity meter in the equipment room. The normal humidity should be between 5% and 95%. Step 3 Check if the equipment room meets the disaster protection requirements. Ensure the following points:
l
There should be portable foam fire extinguishers in the equipment room. The fire extinguishers should be in their service life. There should be no rain leakage or water penetration in the equipment room. There should be no mice or insects in the equipment room.
l l
Step 4 Clean the equipment room. Ensure that there is no dust on the cabinets, on the equipment shells, in the equipment, on the desks, or on the floor. The equipment should be tidy. ----End
Prerequisite
None.
Procedure
Step 1 Ensure that the ODU is within the protected area of the lightning arrester. For plain areas, the lightning arrester protects the area that is located within an angle of 45 under it. For mountainous areas and the areas where lightning frequently occurs, the lightning arrester protects the area that is located within an angle of 30 under it. Step 2 Ensure that the ODU is reliably fixed on the antenna. Step 3 Ensure that the ODU is not damaged. Step 4 Ensure that the interface between the ODU and the antenna is waterproof. Step 5 Ensure that the protection grounding cable of the ODU is firmly and reliably grounded. ----End
Prerequisite
None.
Procedure
Step 1 Ensure that the coupler is within the protected area of the lightning arrester. For plain areas, the lightning arrester protects the area that is located within an angle of 45 under it. For mountainous areas and the areas where lightning frequently occurs, the lightning arrester protects the area that is located within an angle of 30 under it. Step 2 Ensure that the coupler is reliably fixed on the antenna. Step 3 Ensure that the coupler is not damaged. Step 4 Ensure that the interface between the coupler and the antenna is waterproof. Step 5 Ensure that the interface between the coupler and the ODU is waterproof. ----End
Issue 06 (2007-12-30) Huawei Technologies Proprietary 1-9
Prerequisite
None.
Procedure
Step 1 Ensure that the antenna is within the protected area of the lightning arrester. For plain areas, the lightning arrester protects the area that is located within an angle of 45 under it. For mountainous areas and the areas where lightning frequently occurs, the lightning arrester protects the area that is located within an angle of 30 under it. Step 2 Ensure that the antenna is reliably fixed on the mast. Step 3 Ensure that the antenna radome is not damaged. Step 4 Ensure that there is no accumulated water in the antenna. Step 5 Check if the fastening bolts on the antenna are loose. Check if the antenna slants from the original position. Ensure that the azimuth angle and the elevation angle of the antenna meet the planned requirements. Step 6 In the case of split mounting, ensure that the installation parts (ODU adapter, antenna adapter, and flexible waveguide) are installed firmly, and that the connectors are fastened. ----End
Prerequisite
None.
Procedure
Step 1 Check the appearance of cables.
l l l
There should be no bent or twisted cable. There should be no bare copper wire. The bending radius of the cable should be more than 30 cm.
Huawei Technologies Proprietary Issue 06 (2007-12-30)
1-10
The cable connector should be reliably connected to the ODU. The cable connector should be waterproof.
The grounding clip should be waterproof. The grounding cable should be routed from top downwards. The angle between the grounding cable and the IF cable should not be more than 15 degrees.
----End
Issue 06 (2007-12-30)
1-11