HIPERION ODU INSTALLATION GUIDE

ATL Hiperion ODU

PDH-Radio

INSTALLATION GUIDE

Ver. 1.2
HIPERION ODU

January 2013. Page 1

HIPERION ODU INSTALLATION GUIDE

Information in this document is relevant only to the AT Communications Hiperion series of Digital Microwave Radio equipment and is subject to change without notice. It is not be used for any other purpose, or any other equipment. No part of this publication may be reproduced or distributed in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of AT Electronic & Communication International Limited. E&OE. Copyright 2013 by AT Communications Limited, All Rights Reserved.

TRADEMARKS AT Communications Hiperion series and HINet are registered trademarks of AT Electronic & Communication International Limited.

Any other products or services referred to in this document are the trademarks, service marks, or product names of their respective holders.

DISCLAIMER: The products and specifications, configurations, and other technical information regarding the products contained in this document are subject to change without notice. All the statements, technical information, and recommendations contained in this document are specific to the AT Communications Hiperion series of Digital Microwave Radio equipment and are believed to be accurate and reliable but are presented without warranty of any kind, and users must take full responsibility for the application of any products specified in this manual.

IN NO EVENT SHALL AT COMMUNICATIONS LIMITED, OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF AT COMMUNICATIONS LIMITED HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

HIPERION ODU

Page 2

HIPERION ODU INSTALLATION GUIDE

0.1 CONTENTS
Section 0.1 0.2 0.3 0.4 1 2 3 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.2 3.2.1 3.2.2 3.2.3 3.2.4 4 5 6 7 8 Page CONTENTS ........................................................................................................................... 3 INDEX OF FIGURES ............................................................................................................. 4 SAFETY NOTICES AND ADMONISHMENTS ...................................................................... 5 SERVICING POLICY AND RETURN OF EQUIPMENT ....................................................... 6 HIPERION MW ODU INTRODUCTION ................................................................................ 7 MW ODU IDENTIFICATION .................................................................................................. 7 ODU INSTALLATION ............................................................................................................ 9 ODU INSTALLATION IN AN UNPROTECTED CONFIGURATION ..................................... 9 ODU INSTALLATION DIRECT MOUNT ............................................................................ 9 ODU INSTALLATION REMOTE MOUNT ........................................................................ 11 SURGE PROTECTOR INSTALLATION ............................................................................. 13 CONNECTING IF CABLE ................................................................................................... 13 WATERPROOFING MEASURES ....................................................................................... 13 ODU INSTALLATION IN PROTECTED CONFIGURATION ............................................... 13 ODU INSTALLATION .......................................................................................................... 13 SURGE PROTECTOR INSTALLATION ............................................................................. 16 CONNECTING THE IF CABLES ......................................................................................... 17 WATERPROOFING MEASURES ....................................................................................... 17 FINAL INSPECTION AFTER ODU INSTALLATION ........................................................... 17 MAINTENANCE AFTER ODU INSTALLATION .................................................................. 17 SPECIFICATIONS ............................................................................................................... 19 GLOSSARY OF TERMS ..................................................................................................... 20 RECOMMENDATIONS AND STANDARDS ....................................................................... 21

HIPERION ODU

Page 3

HIPERION ODU INSTALLATION GUIDE

0.2 INDEX OF FIGURES


Section Page

Figure 1: ODU interfaces description .............................................................................. 9 Figure 2: Attach ODU onto antenna ................................................................................ 9 Figure 3: Latch locking buckles ..................................................................................... 10 Figure 4: Vertical polarization ........................................................................................ 11 Figure 5: Horizontal polarization .................................................................................... 11 Figure 6: Lengths of Flextwist Waveguide..................................................................... 12 Figure 7: Latch locking buckles ..................................................................................... 12 Figure 6: Attach coupler to antenna .............................................................................. 14 Figure 7: Latch locking buckles ..................................................................................... 14 Figure 8: ODU installation in protected system ............................................................. 15 Figure 9: Installed ODU in protected system ................................................................. 16 Figure 10: Surge protector ............................................................................................ 16 Figure 11: Right angle adaptor ...................................................................................... 17

HIPERION ODU

Page 4

HIPERION ODU INSTALLATION GUIDE

0.3

SAFETY NOTICES AND ADMONISHMENTS

This document contains safety notices in accordance with appropriate standards. In the interests of conformity International symbols are used. Any installation, adjustment, maintenance and repair of the equipment must only be carried out by trained, authorised personnel. At all times, personnel must comply with any safety notices and instructions. Specific hazards are indicated by symbol labels on or near the affected parts of the equipment. The labels conform to international standards, are triangular in shape, and are colored black on a yellow background. An informative text label may accompany the symbol label. Hazard labelling is supplemented by safety notices in the appropriate equipment manual. These notices contain additional information on the nature of the hazard and may also specify precautions.

Warning: These draw the attention of personnel to hazards which may cause death or injury to the operator or others. Examples of use are cases of high voltage, laser emission, toxic substances, point of high temperature, etc. This equipment operates at High Voltage. Any electrical work including connection and disconnection must be carried out by a qualified and licensed Electrical Contractor. At Electronic & Communication International Limited is not responsible for any damage or injury caused by incorrect or faulty electrical installation.

Alert: These draw the attention of personnel to hazards which may cause damage to the equipment. An example of use is the case of static electricity hazard. Caution notices may also be used in the handbook to draw attention to matters that do not constitute a risk of causing damage to the equipment but where there is a possibility of seriously impairing its performance, e.g. by mishandling or gross maladjustment. Warnings and Cautions within the main text do not incorporate labels and may be in shortened form.

HIPERION ODU

Page 5

HIPERION ODU INSTALLATION GUIDE

0.4

SERVICING POLICY AND RETURN OF EQUIPMENT

The repair of individual units and modules of this equipment is not considered possible without factory facilities. It is, therefore, the policy of ATECIL that faulty units or modules are returned to the local ATCIL office for repair. To enable an efficient, prompt after sales service to be provided for the diagnosis, repair and return of any faulty equipment, please comply with the following requirements. Before any item is returned, a request for the Return Materials Authorisation (RMA) number must be requested by contacting the nearest ATECIL Links office by email or fax. The Numbered RMA form will be returned from the nearest ATECIL Links office by email or fax. ATECIL will not be responsible for any items sent to ATECIL without first requesting a RMA number. Items to be sent for repair must be insured and packaged so as to provide both maximum electrostatic and physical protection and the completed RMA Form giving the required information must be included. ATECIL will not be responsible for any items sent to ATECIL, which are damaged in freight and transport. Physical damage will also void any applicable warranty. This request must be included with the item for repair, items for repair should be sent to the nearest ATECIL office or affiliate from the following list:

Africa email: FAX:

africa@at-communication.com +27 8 6510 5556

Americas email: FAX:

info@at-communication.com +1 41 6352 5966

Asia email:

asia@at-communication.com

Australia, New Zealand, and Pacific Islands email: FAX:

oc@at-communication.com +61 7 3351 1423

Europe email: FAX:

europe@at-communication.com +44 20 7681 2989

Russia and CIS email:

cis@at-communication.com

Middle East email:

me@at-communication.com

HIPERION ODU

Page 6

HIPERION ODU INSTALLATION GUIDE

1 HIPERION MW ODU INTRODUCTION


The Hiperion series of ODUs represents the depth of Hiperions extensive RF technical expertise, advanced designs and many years of manufacturing and testing experience. The ODUs are the most technically advanced on the market are compact, light weight and are highly reliable with low power consumption, giving exceptional MTBF. The Hiperion ODUs for digital microwave radio links are full-featured radios designed to be incorporated in radio links working across a variety of frequencies from 6 GHz to 38 GHz and meeting carrier-grade standards for reliability, quality and environmental compliance. The ODUs feature selectable RF Bandwidths with programmable RF Channel Filtering, very low receiver thresholds and Phase Noise, industry leading Frequency Stability and selectable via software, a full range Automatic Transmit Power Control. Three variants of the ODU are available: 6 GHz to 38 GHz, Standard Power, QPSK, 16QAM and 32QAM only 6 GHz to 38 GHz, Standard Power, QPSK and 16QAM to 256QAM 6 GHz to 38 GHz, High Power, QPSK and 16QAM to 256QAM

This document covers the ODU installation both in unprotected configuration and protected configuration and is intended to be read in conjunction with the Hiperion Antenna Installation Manual, and ATL-CB Redundancy Splitter Installation Manual.

2 MW ODU IDENTIFICATION
All products are described by a Part Number that describes the Saleable Entities. Part Number (P/N) can be recognized as an alphanumeric code seen on the equipment label, depending on the product variant, part number can be divided by constructing it from a group of Saleable Entitles: Below is a description of Hiperion ODU identification Part Numbering scheme:

HIPERION ODU

Page 7

HIPERION ODU INSTALLATION GUIDE

HIPERION ODU

Page 8

HIPERION ODU INSTALLATION GUIDE

3 ODU INSTALLATION
The Hiperion ODU can be directly mounted onto antenna and Redundancy Coupler without any tools. Below is the interface description of Hiperion ODU.

Antenna port waveguide GND RSSI port BNC connector IF port N type connector Locking buckle

Figure 1: ODU interfaces description

3.1 3.1.1

ODU INSTALLATION IN AN UNPROTECTED CONFIGURATION ODU INSTALLATION DIRECT MOUNT

Use the figures below as a guide to installing the ODU in an unprotected configuration:

Figure 2: Attach ODU onto antenna

HIPERION ODU

Page 9

HIPERION ODU INSTALLATION GUIDE

Figure 3: Latch locking buckles

Adjust the antenna to the desired polarization (refer to Hiperion 0.3m_0.6m Antenna Installation Manual and the Hiperion 1.2m Antenna Installation Manual for details). Vertical polarization is indicated by an upward pointing arrow and the letter V, see figure 4. Horizontal polarization is with the ODU rotated 90 clockwise, see figure 5. Make sure the ODU polarization is consistent with antenna polarization. Attach ODU onto antenna and hook each locking buckle. Latch each locking buckles. Verify the waveguide port on ODU is connected properly with the interface flange on the antenna before tightening each lock buckle. A padlock or tie wires can be installed through the eye of the latch to ensure ODU security.

HIPERION ODU

Page 10

HIPERION ODU INSTALLATION GUIDE

Figure 4: Vertical polarization

Figure 5: Horizontal polarization

3.1.2

ODU INSTALLATION REMOTE MOUNT

In this instance, the ODU is attached to a Remote Mount Adaptor, and the adaptor connected to the antenna with a length of flexible Rectangular Waveguide (Flextwist). The Flextwist may come in a variety of lengths, depending on the frequency band of operation. Generally these lengths vary from 0.6m to 1.2 m. The ODU Remote Mount Adaptor must be located as close as possible to the antenna to allow the Flextwist be be installed without any strain on the rubber jacket or the flexible copper inner tube. Use the figures below as a guide to installing the ODU and ODU Remote Mount ODU in an unprotected configuration:

HIPERION ODU

Page 11

HIPERION ODU INSTALLATION GUIDE

Figure 6: Lengths of Flextwist Waveguide.

Figure 7: Latch locking buckles

HIPERION ODU

Page 12

HIPERION ODU INSTALLATION GUIDE

Attach the ODU to the ODU Remote Mount Adaptor hooking each locking buckle. Latch each locking buckles. Attache the Flextwist to the ODU Remote Mount Adaptor using the provided gaskets and fasteners. Attach the Flextwist to the flange on the antenna using the provided gaskets and fasteners.. A padlock or tie wires can be installed through the eye of the latch to ensure ODU security.

3.1.3

SURGE PROTECTOR INSTALLATION

A Surge Protector is provided to be connected on the ODU to achieve lightning protection. This surge protector is installed together with the grounding of ODU. Connect the surge protector at the N Type connector IF interface of ODU. Fix the Ground Wire to the grounding terminal of theODU and the metal fasteners of the tower or mast. This wire must be as short as possible.

3.1.4

CONNECTING IF CABLE

This refers to the connection between ODU and IDU. Before connecting the IF cable, ensure that the IDU is powered OFF. Locate and connect the IF cable to the N-type connector of the installed Surge Protector, and the other end of the IF cable goes to the Surge Protector mounted to the IF interface on the IDU.

3.1.5

WATERPROOFING MEASURES

After all the screws, bolts and nuts are tightened, seal the surge protector assembly and connector of the IF cable using self vulcanising tape covered by a waterproof and UV resistant tape.

3.2

ODU INSTALLATION IN PROTECTED CONFIGURATION

3.2.1

ODU INSTALLATION

Use the figures below as a guide to installing the ODU in the protected configuration:

HIPERION ODU

Page 13

HIPERION ODU INSTALLATION GUIDE

Figure 8: Attach coupler to antenna

Figure 9: Latch locking buckles

HIPERION ODU

Page 14

HIPERION ODU INSTALLATION GUIDE

Adjust the antenna to the desired polarization (refer to Hiperion 0.3m_0.6m Antenna Installation Manual and the Hiperion 1.2m Antenna Installation Manual for details). Adjust the antenna to the desired polarization (refer to Hiperion 0.3m_0.6m Antenna Installation Manual and the Hiperion 1.2m Antenna Installation Manual for details).

Adjust the coupler to the expected polarization (refer to ATLL-CB Redundancy Coupler for details). Make sure the coupler polarization is consistent with antenna polarization. Vertical polarization is indicated by an upward pointing arrow and the letter V see figure 4. Horizontal polarization is with the ODU rotated 90 clockwise, see figure 5. Make sure the ODU polarization is consistent with antenna polarization. Attach ODU onto antenna and hook each locking buckle. Latch each locking buckles. Verify the waveguide port on ODU is connected properly with the interface flange on the antenna before tightening each lock buckle. A padlock or tie wires can be installed through the eye of the latch to ensure ODU security.

Figure 10: ODU installation in protected system HIPERION ODU Page 15

HIPERION ODU INSTALLATION GUIDE

Attach one ODU to coupler and hook the locking buckles. Verify the waveguide port on ODU is connected properly with the feed flange on coupler before tightening each lock buckle. Follow steps above to install another ODU to coupler.

Figure 11: Installed ODU in protected system

3.2.2

SURGE PROTECTOR INSTALLATION

Figures below present the appearance of surge protector and right angle adaptor.

Figure 12: Surge protector

HIPERION ODU

Page 16

HIPERION ODU INSTALLATION GUIDE

Figure 13: Right angle adaptor When the 1+1 configuration is applied, a right angle adaptor can be used as the connector between the surge protector and IF cable to make the installation of surge protector easier. To install the right angle adaptor, connect one end to the ODU IF interface, while the other end goes to the surge protector. Each ODU should be equipped with a surge protector. Connect the surge protector at the N Type connector IF interface of ODU. Fix the Ground Wire to the grounding terminal of theODU and the metal fasteners of the tower or mast. This wire must be as short as possible.

3.2.3

CONNECTING THE IF CABLES

This refers to the connections between the ODUs and the IDUs. Before connecting the IF cable, ensure that the IDUs are powered OFF. Locate and connect the IF cable to the N-type connector of the installed Surge Protector, and the other end of the IF cable goes to the Surge Protector mounted to the IF interface on the IDU.

3.2.4

WATERPROOFING MEASURES

After all the screws, bolts and nuts are tightened, seal the surge protector assemblies and connectors of the IF cables using self vulcanising tape covered by a waterproof and UV resistant tape.

4 FINAL INSPECTION AFTER ODU INSTALLATION


When the installation of the ODU has been completed, make sure that the installation instructions have been followed. Its especially important to check that all locking buckles are properly locked.

5 MAINTENANCE AFTER ODU INSTALLATION


After equipment commissioning, no further maintenance by hand is required. After NMS commissioning, the monitoring centre can control the operational status of all of the equipment in the network. The following regular inspections are recommended to ensure long life system performance.

HIPERION ODU

Page 17

HIPERION ODU INSTALLATION GUIDE

Antenna systems should be inspected once a year by qualified personnel to verify proper installation, maintenance, and the condition of equipment. This should include a comparassion of the RSL with the RSL as noted in the Commissioning Document. Note that for this comparassion, weather conditions should be similar to those at the time of installation. The Station and System Earthings should be inspected every 12 months for integrity and low ground resistance. Periodically check for proper connection and tightening of all cables and mounting fixtures. Make sure that the ATL Hiperion ODU has not been damaged, disassembled or otherwise tampered with.

Ensure that the ATL Hiperion ODU remains properly grounded as described in the previous sections. Cleaning the surface of the equipment regularly to remove dust and other deposits like salt for exxample, to ensure the normal operation and prolonging the useful life of the equipment. The Surge Arrestors are designed to be sacrificial. Inspect the Surge Arrestor devices for integrity. Replace any that do not meet electrical specifications or appear suspect on physical examination. The installation location for ATL Hiperion ODU should remain well ventilated.

ATECIL disclaims any liability or responsibility for the results of improper or unsafe installation practices.

The ATL- ODUs have no user serviceable parts internally. In the event of a hardware fault, the faulty unit must be replaced with a known functional unit and returned to ATECIL for repair.

NOTE: Information in this document may be subject to changes without notice.

HIPERION ODU

Page 18

HIPERION ODU INSTALLATION GUIDE

6 SPECIFICATIONS

Add 4 dB to Tx Power for High Power models.


HIPERION ODU Page 19

HIPERION ODU INSTALLATION GUIDE

7 GLOSSARY OF TERMS

10Base-T 100Base-T AGC AIS ALM ATECIL ATPC AUX ADM ATM BER BERT CPU CCITT CIT DC DEM DEMUX ES ESD E1 EOW ETH FTP GND IF LAN LED LOS MIB MSAIS M&C MDU MUX NMS ODU PDH QAM PSTN RBER RF RIM RMT RLTS RSL RSSI RSPI SDH SSPA SNMP TCA TIM TX

10Mbit/s Baseband Unshielded Twisted Pair Cable 100Mbit/s Baseband Unshielded Twisted Pair Cable Automatic Gain Control Alarm Indication Signal Alarm AT Electronic & Communication International Limited Automatic Transmit Power Control Auxiliary Data Channel Add/Drop Multiplexer Asynchronous Transfer Mode Bit Error Rate Bit Error Rate Tester Central Processing Unit International Telephone and Telegraph consultative committee Craft Interface Terminal Direct current Demodulation DeMutiplex Error Second Electricity-static discharge Framing specification for synchronous digital streams at 2.048Mbit/s. Engineering order wire Ethernet File Transfer Protocol Ground Intermediate Frequency Local Area Network Light-Emitting Diode Loss of Signal Management Information Base Multiplex Section Alarm Indication Signal Monitor and Control Modem Unit Multiplexer/Demultiplexer Network Management System Outdoor Unit Plesiochronous Digital Hierarchy Quadrature Amplitude Modulation Public Switched Telephone Network Remainder Bit Error Rate Radio Frequency Replaceable Interface Module Remote Received Level Threshold Second Received signal level Received signal strength indication Radio Synchronous Physical Interface Synchronous Digital Hierarchy Solid State Power Amplifier Simple network management protocol Threshold Crossing Alarm Trace Identifier Mismatch Transmitter

HIPERION ODU

Page 20

HIPERION ODU INSTALLATION GUIDE

8 RECOMMENDATIONS AND STANDARDS

The AT Electronic & Communication International Limited, Hiperion series of Digital Microwave Radio Link equipment, has been tested and fully complies with the following recommendations and standards:

ACMA: A-Tick, N28669 (Australia, New Zealand and Pacific Islands Compliance). ACMA: C-Tick, N28669 (Australia, New Zealand and Pacific Islands Compliance). ANSI/IEEE Std 802.11, 1999 Edition (R2003): Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications. CEPT/ERC Recommendation 74-01: "Spurious emissions". EEU R&TTE Directive 1999 IEC 60154: "Flanges for waveguides". EN 609 50: "ETSI CE". EN 300 127: Electromagnetic compatibility and Radio spectrum Matters (ERM); Radiated emission testing of physically large telecommunication systems. ETR 241: Transmission and Multiplexing (TM); Functional architecture of 2 Mbit/s based Plesiochronous Digital Hierarchy (PDH) transport networks. ETS 300 371: Transmission and Multiplexing (TM); Plesiochronous Digital Hierarchy (PDH) information model for the Network Element (NE) view. ETS 300 785: Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH); Radio specific functional blocks for transmission of M x sub-STM-1. ETSI EN 300 019: Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at non-weather protected locations. ETSI ETS 300 019 (Parts 1 and 2): "Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1: Classification of environmental conditions; Part 2: Specification of environmental tests". ETSI ETS 300 119: "Equipment Engineering (EE); European telecommunication standard for equipment practice". ETSI ETS 300 132 (Part 2): "Equipment Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 2: Operated by direct current (dc)". ETSI EN 300 197: Fixed Radio Systems; Point-to-point equipment; Parameters for radio systems for the transmission of digital signals operating at 32 GHz and 38 GHz HIPERION ODU Page 21

HIPERION ODU INSTALLATION GUIDE

ETSI EN 300 198: Fixed Radio Systems; Point-to-point equipment; Parameters for radio systems for the transmission of digital signals operating at 23 GHz. ETSI EN 300 385: "Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for fixed radio links and ancillary equipment". ETSI EN 300 431: Fixed Radio Systems; Point-to-point equipment; Parameters for radio system for the transmission of digital signals operating in the frequency range 24,50 GHz to 29,50 GHz. ETSI EN 300 462-4-2: Transmission and Multiplexing (TM); Generic requirements for synchronization networks; Part 4-2: Timing characteristics of slave clocks suitable for synchronization supply to Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) equipment; Implementation Conformance Statement (ICS) proforma specification. ETSI EN 300 639: Fixed Radio Systems; Point-to-point equipment; Sub-STM-1 digital radio systems operating inthe13 GHz,15 GHz and 18 GHz frequency bands with about 28 MHz co-polar and 14 MHz cross-polar channel spacing. ETSI EN 300 786: Fixed Radio Systems; Point-to-point equipment; Sub-STM-1 digital radio systems operating in the13 GHz, 15 GHz and 18 GHz frequency bands with about 14 MHz co-polar channel spacing. ETSI EN 300 833: Fixed Radio Systems; Point-to-point antennas; Antennas for point-to-point fixed radio systems operating in the frequency band 3 GHz to 60 GHz. ETSI EN 301 128: Fixed Radio Systems; Point-to-point equipment; Plesiochronous Digital Hierarchy (PDH); Low and medium capacity digital radio systems operating in the 13 GHz, 15 GHz and 18 GHz frequency bands ETSI EN 300 197: Fixed Radio Systems; Point-to-point equipment; Parameters for radio systems for the transmission of digital signals operating at 32 GHz and 38 GHz. ETSI EN 300 198: Fixed Radio Systems; Point-to-point equipment; Parameters for radio systems for the transmission of digital signals operating at 23 GHz. ETSI EN 301 216: Fixed Radio Systems; Point-to-point equipment; Plesiochronous Digital Hierarchy (PDH); Low and medium capacity digital radio systems operating in the frequency bands between 3 GHz and 11 GHz. ETSI EN 301 384: Telecommunications Management Network (TMN); Performance monitoring for Plesiochronous Digital Hierarchy (PDH) interfaces; Information model for the Network Element (NE) view. ETSI EN 301 390: Fixed Radio Systems; Point-to-point and Multipoint Systems; Spurious emissions and receiver immunity limits at equipment/antenna port of Digital Fixed Radio Systems. ETSI EN 301 489-4: "Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 4: Specific conditions for fixed radio links and ancillary equipment and services". ETSI EN 301 751: Fixed Radio Systems; Point-to-Point equipments and antennas; HIPERION ODU Page 22

HIPERION ODU INSTALLATION GUIDE

Generic harmonized standard for Point-to-Point digital fixed radio systems and antennas covering the essential requirements under article 3.2 of the 1999/5/EC Directive. ETSI EN 301 785: Fixed Radio Systems; Point-to-point packet data equipment; Parameters for radio systems with packet data interfaces for transmission of digital signals operating in the frequency range 7, 8, 13, 15, 18, 23, 26, 28, 32, 38, 52 to 55 GHz. ETSI EN 301 787: Fixed Radio Systems; Point-to-Point equipment; Parameters for radio systems for the transmission of Sub-STM-0 digital signals operating in the 18 GHz frequency band ETSI EN 302 217-1: Fixed Radio Systems; Characteristics and requirements for point-to-point equipment and antennas; Part 1: Overview and system-independent common characteristics. ETSI EN 302 217-2: Fixed Radio Systems; Characteristics and requirements for point-to-point equipment and antennas; Part 2-1: System-dependent requirements for digital systems operating in frequency bands where frequency co-ordination is applied. ETSI EN 302 217-2: Fixed Radio Systems; Characteristics and requirements for point-to-point equipment and antennas; Part 2-2: Harmonized EN covering essential requirements of Article 3.2 of R&TTE Directive for digital systems operating in frequency bands where frequency co-ordination is applied. ETSI EN 302 217-3: Fixed Radio Systems; Characteristics and requirements for point-to-point equipment and antennas; Part 3: Harmonized EN covering essential requirements of Article 3.2 of R&TTE Directive for equipment operating in frequency bands where no frequency co-ordination is applied. ETSI EN 302 217-4: Fixed Radio Systems; Characteristics and requirements for point-to-point equipment and antennas; Part 4-1: System-dependent requirements for antennas ETSI TR 101 036-1: "Fixed Radio Systems; Point-to-point equipment; Generic wordings for standards on digital radio systems characteristics; Part 1: General aspects and point-to-point equipment parameters". ETSI TR 101 854: Fixed Radio Systems; Point-to-point equipment; Derivation of receiver interference parameters useful for planning fixed service point-to-point systems operating different equipment classes and/or capacities. ETSI TR 102 243-1: Fixed Radio Systems; Representative values for transmitter power and antenna gain to support inter- and intra-compatibility and sharing analysis; Part 1: Digital point-to-point systems. NTRL ANSI/UL 1950: FCC FCC Part 15 CLASS A digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the Hiperion series Installation Manual, may cause harmful interference to radio communications. ITU-R Recommendation F.385-6: Radio Frequency Channel Arrangements for Radio Relay Systems operating in the 7 GHz Band. HIPERION ODU Page 23

HIPERION ODU INSTALLATION GUIDE

ITU-R Recommendation F.386-4: Radio Frequency Channel Arrangements for Radio Relay Systems operating in the 8 GHz Band. ITU-R Recommendation F.557-4: "Availability objective for radio-relay systems over a hypothetical reference circuit and a hypothetical reference digital path". ITU-R Recommendation F.746-4: "Radio-frequency channel arrangements for radio-relay systems". ITU-R Recommendation F.752-1: "Diversity techniques for radio-relay systems". ITU-R Recommendation F.1092-1: "Error performance objectives for constant bit rate digital path at or above the primary rate carried by digital radio-relay systems which may form part of the international portion of a 27 500 km hypothetical reference path". ITU-R Recommendation F.1093-1: "Effects of multi-path propagation on the design and operation of line-of-sight digital radio-relay systems". ITU-R Recommendation F.1101: "Characteristics of digital radio-relay systems below about 17 GHz". ITU-R Recommendation F.1189-1: "Error performance objectives for constant bit rate digital paths at or above the primary rate carried by digital radio-relay systems which may form part or the entire national portion of a 27 500 km hypothetical reference path". ITU-R Recommendation F.1191-1: "Bandwidth and unwanted emissions of digital radio-relay systems" ITU-T Recommendation G.703: "Physical/electrical characteristics of hierarchical digital interfaces". ITU-T Recommendation G.704: "Synchronous frame structures used at 1544, 6312, 2048, 8488 and 44736 Kbit/s hierarchical levels". ITU-T Recommendation G.773: "Protocol suites for Q-interfaces for management of transmission systems". ITU-T Recommendation G.826: "Error performance parameters and objectives for international, constant bit rate digital paths at or above the primary rate". ITU-T Recommendation G.827: "Availability parameters and objectives for path elements of international constant bit-rate digital paths at or above the primary rate".

End of Document