Академический Документы
Профессиональный Документы
Культура Документы
Span Diameter of the Column Height of the Pole Eaves Height Pitch of Shade Bay Width 6m 168 3.3 2.4 0.4 5.515 mm m m m Pitch
SECTION
Member Properties
Diameter Main Pole Pyramid Members Chord Bottom Tie Lateral Tie Thickness 165 5 mm 48 3.2 mm 88.9 4 mm 88.9 4 mm 60.3 4 mm
Pyramid Members
Chord Loadings Dead Load Weight of Fabric (On Main Frame) Weight of Fabric (On Pyramid Members) Weight of Fabric (On Lateral Ties) Wind Loads Basic Wind Speed (Km/hr) Basic Wind Speed (m/sec) Topographical Factor Ground Factor Statical Factor Effective Wind Speed Wind Pressure
0.006657 Kn/m Lateral Tie 100 Km/Hr PLAN 28 1 0.8 Class B 1 22 0.303
7.192
Cp -ve (Upwards)
Wind Forces 1.34 Kn/m Downward +ve force on Main Frame 1.01 Kn/m Downward force on Pyramid Member Downward force on Lateral ties Upward -ve force on Main Frame Upward force on Pyramid Member Upward force on Lateral Ties Frictional Drag Horizontal force on Column
0.38 Kn/m