Вы находитесь на странице: 1из 16

Product Catalog 2013

DV Power Products Catalog

About DV Power

Reliable test devices for reliable electric power systems


The company with the headquarters in Stockholm, Sweden was founded in 2000 by the group of engineers with an extensive experience in the power electronics technology area. Under the trade mark "DV Power" the company develops, manufactures and markets the new generation of the test and measurement equipment for the electric power industry. Our products are PORTABLE - Up to two or three times lighter than similar devices from our competitors. PRACTICAL - Can use lighter/thinner cables. USER-FRIENDLY - Completely automated sage in test processes. EFFICIENT - Modern switch techniques, power electronics, sophisticated design. ACCURATE - Typical accuracy of our products is 0,1 %. ROBUST - Our devices are built in metal or plastic cases. The rigid design makes our products ideal for use in high voltage substations and industrial environments. COMPLIANT - IEC and other applicable international standards, CE approved.
SALES page 4-5 page 6 page 6-7 page 7-9 The price list and additional information on delivery terms can be received from the DV Power area/country distributor or directly via the e-mail: sales@dv-power.com. DV Power has a rising presence on the World Market, with over 50 representatives and distributors worldwide. DV Power products can be found and are in use in more than 70 countries. WARRANTY DV Power provides a three year warranty on all its products. That is a guarantee to our customers that they will receive the highest quality instrumentation available. TECHNICAL SUPPORT Our technical support is always available to help you. You may call at +46 70 0925 000 or e-mail to support@dv-power.com. We will always respond within 24 hours.

Circuit Breaker Test Equipment Micro Ohmmeters RMO series Coil Analyzers SAT series

Coil Testers & Breaker Suppliers POB series

Circuit Breaker Analyzers and Timers CAT series

Transformer/Motor Test Equipment

Winding Ohmmeters & Tap Changer Analyzer page 10 RMO-T series Tap-Changer & Winding Analyzer TWA30D Three-Phase Transformer Turns Ratio Tester TRT series Three-Phase Transformer Demagnetizer DEM60C Motor & Generator Winding Ohmmeters RMO-M series Accessories & Software page 13 page 14 page 14 page 15

page 11-12

www.dv-power.com

Circuit Breaker Test LOREM LOREM IPSUM \ IPSUM Equipment


RMO-A Series High DC Current Micro Ohmmeters
The High DC Current Micro Ohmmeters RMO-A series instruments are designed to provide safer, faster and easier resistance measurements of: High, middle and low voltage circuit breakers Disconnecting switches High-current busbar joints Cable splices Welding joints Micro ohmmeter RMO600A Lightweight - only 8 kg Powerful 5 A - 600 A DC True DC (ripple free) current Measuring range 0,1 - 999,9 m Max. resolution 0,1 DV-Win software Optional Accessories Test Shunt 100 Transport case Thermal printer (built in)

RMO-A Series RMO100A RMO200A RMO300A RMO400A RMO500A RMO600A RMO60E (Earthing)

RMO-G Series Micro ohmmeter With Both Sides Grounded Feature


The High DC Current Micro Ohmmeters RMO-G series instruments are mounted in plastic housings and have an additional Both Sides Grounded feature as an extension to its versatile list of measurement possibilities. Micro ohmmeter RMO600G Lightweight - only 9,5 kg Powerful 5 A - 600 A DC True DC (ripple free) current Measuring range 0,1 - 999,9 m Max. resolution 0,1 Single/Continuous/CC Mode DV-Win software RMO-G Series RMO100G RMO200G RMO300G RMO400G RMO500G RMO600G RMO800G Optional Accessories Thermal printer (built in) Test Shunt 100 Both sides grounded unit (Current clamp) Remote control Cable plastic case

DV Power Products Catalog

Circuit Breaker Test Equipment


During the HV circuit breaker contact resistance measurement, an efficient way of insuring protection from the induced voltages is to ground the tested circuit breaker on both sides. RMO-G series instruments have the possibility to perform measurements with both sides of a test object grounded. This will ensure the safety of the operators and protect the instrument as well. The figure on the right, presents the connection diagram of the instrument to the high voltage circuit breaker with both sides grounded. In order to remotely perform the measurements, the RMO-G devices are provided with the RMO Remote Control Unit. In addition, it enables multiple measurements to be performed with the same test current. This significantly speeds up the entire test procedure.

RMO-D Series Micro ohmmeter With Demagnetization Feature


The High DC Current Micro Ohmmeters RMO-D series instruments are the most advanced version of RMO series instruments. The additional feature is the ability to perform fully automatic demagnetization of a current transformer core after the measurement. Demagnetizing a magnetic core of a current transformer requires alternating current to be applied with a decreasing magnitude down to zero. Using the proprietary solution design the RMO-D series instruments provide the appropriate magnitudes and alternates by internally changing the polarity of a controlled DC current.

RMO-D Series RMO200D RMO500D RMO600D

Micro ohmmeter RMO600D Lightweight - only 11 kg Powerful 5 A - 600 A DC True DC (ripple free) current Measuring range 0,1 - 999,9m Max. resolution 0,1 Single/Continuous/CC Mode Demagnetization of a CT core on the dead tank CB DV-Win software

Optional Accessories Both sides grounded unit (Current clamp) Remote control Thermal printer (built in) Test Shunt 100 Cable plastic case

Technical specification RMO Series Mains power supply Typical accuracy 0,1 - 999,9 Measuring range 1000 - 9999 90 V 264 V AC, 50 / 60 Hz (0,1 % rdg + 0,1 % FS) Resolution 1 0,1

10,00 m - 99,99 m

100,0 m - 999,9 m

10

0,1 m

www.dv-power.com

Circuit Breaker Test LOREM LOREM IPSUM \ IPSUM Equipment


SAT Series Circuit Breaker Coil Analyzer
The Coil Analyzer SAT series instruments are ideal for testing circuit breakers, where substation battery is not connected or available. These devices are compatible with breaker analyzers from different vendors and eliminate use of station batteries during testing. An additionally provided feature on these types of the DV Power instruments is a significant reduction of testing time when using our CAT and SAT devices together.
Technical specification SAT Series Power Output Coils output DC voltage Coils output AC voltage Motor output DC voltage Measuring range 0,5 - 99,9 100 - 999 Minimum trip voltage fully automatic test Start voltage Stop voltage Step voltage Typical accuracy Operating temperature Coil resistance measurement 10 V DC - 300 V DC 10 V AC - 250 V AC 10 V DC - 250 V DC Resolution 0,1 1

Highlights Lightweight only 9,20 kg Coil current measurement Coil resistance measurement Minimum trip voltage test of the circuit breaker's coils Undervoltage release test Supplying spring-charging motors Providing a power supply for breaker analyzers from different vendors

10 V - 299 V DC; 11 V - 300 V DC; 1 V - 20 V DC; -10 C + 50 C

10 V - 249 V AC 11 V - 250 V AC 1 V - 20 V AC

(0,25 % rdg + 0,25 % FS)

POB series AC / DC Power Supply for Circuit Breaker Testing


The Coil Tester & Breaker Supply POB series instruments are the variable voltage power supply units ideal for testing circuit breakers, where substation battery is not connected or available. They are intended for operating breaker coils, and springcharging motors as a part of commissioning and maintenance testing. These devices are compatible with breaker analyzers from different vendors and eliminate use of station batteries during testing.

Highlights Lightweight only 9,20 kg Minimum trip voltage test of the circuit breaker's coils Supplying spring-charging motors Providing a power supply at test with breaker analyzers from different vendors

Main Features Powerful up to 40 A True DC (ripple free) voltage DC Voltage from 10 V to 300 V AC Voltage from 10 V to 250 V

Load Voltage 110 V DC

Current 30 A 24 A 12 A 15 A 12 A 8A

Max Load Interval 20 sec 60 sec continuous 20 sec 60 sec continuous

220 V DC

DV Power Products Catalog

Circuit Breaker Test Equipment


POB30AD POB40AD POB40ADL POB50ADL POB30D POB40D POB40DL POB50DL
Max DC Current 30 A 40 A 40 A 50 A Max AC current 12 A 15 A 15 A 15 A Output DC Voltage 10 V 300 V 10 V 300 V Output AC Voltage 10 V 250 V 10 V 250 V 1 V 40 V 1 V 40 V

1 V 50 V 1 V 50 V

Max DC Current 30 A 40 A 40 A 50 A

Output DC Voltage 10 V 300 V 10 V 300 V 1 V 50 V 1 V 50 V

CAT series - Circuit Breaker Analyzers & Timers


Circuit Breaker Analyzer & Timer CAT series are standalone or PC controlled digital instruments for a condition assessment of circuit breakers. A simultaneous measurement of up to 12 main contacts (4 breaks per a phase) including pre-insertion resistors and 6 auxiliary contacts. CAT series instruments record graphs of both, the open and close coil currents and displacements of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the preinsertion resistors (if present in the circuit breaker). Circuit Breaker Analyzer & Timer CAT64 Simple & easy to operate Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 3 timing channels for auxiliary inputs Resistance measurement of pre-insertion resistors 4 Analog Inputs + 1 Transducer Input Supports both digital and analog transducers Detailed analysis of test results using DV-Win software CAT Series CAT03 CAT31 CAT34 CAT61 CAT125 CAT64 CAT126 CAT65 CAT126D CAT66 CAT66D

www.dv-power.com

Circuit Breaker Test Equipment


Two CAT Device Series
The first series of CAT instruments was designed to meet requirements of an easy to use circuit breaker analyzer & timer with an attractive price. Their primary intention was timing and motion measurement of HV and MV circuit breakers. Series 1 Main contacts and preinsertion resistors contacts timing channels Auxiliary contacts timing channels Coil control Coil current measurement channels CAT03 3 CAT31 3 CAT34 3 CAT61 6 CAT64 6

NO NO NO 2 NO NO Optional NO

3 YES 2 2 NO NO Optional YES

3 YES 2 2 2 1 Optional YES

3 YES 2 2 NO NO Optional YES

3 YES 2 2 2 1 Optional YES

External trigger channels Analog input channels

Transducer input channels Thermal printer (built-in) First trip test

The second series of CAT instruments utilizes the latest enhancements for safe and fast testing, with unique technical capabilities for additional diagnostics of circuit breakers. Sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments. Series 2 Main contacts and preinsertion resistors contacts timing channels Auxiliary contacts timing channels Coil control Coil current measurement channels Analog input channels CAT65 6 CAT66 6 CAT66D 6 CAT125 12 CAT126 12 CAT126D 12

6 YES 4 4 3 Optional YES YES NO NO NO

6 YES 4 4 3 Optional YES YES YES

6 YES 4 4 3 Optional YES YES YES

6 YES 4 4 3 Optional YES YES NO NO NO

6 YES 4 4 3 Optional YES YES YES

6 YES 4 4 3 Optional YES YES YES

Transducer input channels Thermal printer (built-in) First trip test Both Sides Grounded

Micro ohmmeter

Dynamic resistance measurement Demagnetization of CT


8

500 A NO

200 A YES

500 A NO

200 A YES

DV Power Products Catalog

LOREM IPSUM \ IPSUM Equipment Circuit Breaker Test LOREM


BSG (Both Sides Grounded) BSG feature enables safe and fast testing in high voltage substations, without removing the safety ground connections on both sides of the circuit breaker. No additional modules or remote boxes are required. Each main contacts timing channel is able to detect main contacts state in a case when both terminals are grounded. First Trip Test A First trip analysis is important to determine a condition of the coil operating mechanism. A circuit breaker spends most of its lifetime conducting a current without any operation. Once the protective relay detects a problem, the circuit breaker, that was idle for maybe a year or longer, has to operate as fast as possible. However, if the circuit breaker has not been operated for a long time, the latch friction may increase. Information about the latch friction can be obtained from the coil current waveform recorded during the First trip test. Static Resistance Measurement The built-in micro ohmmeter generates a true DC ripple free current with an automatically regulated test ramps. The resistance measurement is using the well known Kelvins four points method. The DC current is generated through the closed circuit breaker contacts. The voltage drop is measured between the terminals of the circuit breakers. The resistance is calculated using the Ohms law R=U/I. DRM (Dynamic Resistance Measurement) The built-in micro ohmmeter can also be used for the DRM. The DRM test is performed by injecting a current through the breaker contact and simultaneously monitoring the voltage drop across the breaker contact as well as the current flow during the operation of the breaker. Resistance curve as a function of contact travel can be used to reveal failures in relation to the arcing contact condition. The test current should be at least 100 A to provide a higher voltage drop to allow easier detection of the arcing contact. The DRM test requires the circuit breaker analyzer with a high resolution measurement.

Demagnetization of a Current Transformer Core after DC Contact Resistance Measurement After a DC current test of a circuit breaker or bus-bars, the magnetic core of associated current transformers may be magnetized (remanent magnetism). To eliminate this source of potential problems, demagnetization should be performed. Following the apparatus resistance measurements, there is a possibility to start the demagnetization process using this instrument. The whole demagnetization process is performed automaticaly and does not require modification of any connections.

www.dv-power.com

Transformer Test Equipment


RMO-TW, TD and TT Series Tap Changer Analyzers & Winding Ohmmeters
The Winding Ohmmeters RMO-TT, -TD and -TW series are designed for the winding resistance measurement of inductive test objects (transformers/generators/motors) and for the on-load tap changer analysis of power transformers. Typical application areas of RMO-TT, -TD and -TW are high-voltage substations and industrial environments. Measuring the winding resistance is an important part of commissioning, maintaining and production of: RMO-TW series RMO10TW RMO20TW RMO30TW RMO50TW RMO-TD series RMO25TD RMO40TD RMO60TD RMO100TD Transformers Generators/motors Electrical machines High-current busbar joints Cable splices RMO-TT series Optional Accessories RMO60TT RMO100TT Transport case Thermal printer (built-in) Test shunt 150 A / 150 mV

All the RMO-TT, -TD and -TW instruments have a resistance measurement accuracy of up to 0,1%. This enables a very reliable determination of the transformer condition. The open circuit voltage of up to 60 V enables a very short transformer charging time. The instruments generate a true DC ripple-free current. The DV-Win software (included in the purchase price) provides additional analysis options, such as creation of test reports, static and dynamic resistance graphs, measurement of the tap changer transition times, the result download, as well as many other features. A Heat Run resistance/temperature extrapolation can also be performed using the software for the RMO-TT instruments. The instruments from the RMO-TT and RMO-TD series also have the automatic demagnetization feature. The process is completely safe, fully automated and very fast. This enables the user to avoid problems such as high inrush currents at the start-up of power transformers, incorrect operation of protective relays, erroneous diagnostics or inaccurate electrical measurement on a transformer. Tap Changer Analyzer & Winding Ohmmeter RMO60TT Three resistance measurements channels Test current 5 mA 60 A DC Three temperature measurement channels Automatic resistance/temperature measurement for the Heat Run test On-load tap changer dynamic resistance measurement Rapid automatic demagnetization AC Current monitoring channel for tap changer motor current measurement Measuring range 0,1 2 k Automatic discharge process Built-in tap changer control unit USB flash drive feature Winding Ohmmeter RMO50TW Two resistance measurement channels Test current 5 mA 50 A DC On-load tap changer verifi cation Measuring range 0,1 - 2 k Automatic discharge circuit Lightweight only 7,5 kg
10 DV Power Products Catalog

Tap Changer Analyzer & Winding Ohmmeter RMO60TD Two resistance measurement channels Test current 5 mA 60 A DC On-load tap changer dynamic resistance measurement Rapid automatic demagnetization Tap changer motor current monitoring channel Measuring range 0,1 2 k Automatic discharge process Built-in tap changer control unit USB flash drive feature

Transformer Test Equipment


TWA30D Tap Changer and Winding Analyzer
Tap-Changer & Winding Analyzer TWA30D is a one-of-a-kind diagnostic solution for power transformer testing. Using this device, the transformer testing is safer, significantly faster, and more convenient. The TWA30D instrument is designed for simultaneous three-phase tap changer analysis and six-winding resistance measurement of both the primary and the secondary transformer windings. The measurement is obtained very quickly by saturating all three legs of the magnetic core at the same time. Once all 6-8 bushings are connected and the transformer configuration selected, the instrument adjusts the test procedure automatically. The TWA30D generates a true DC ripple-free current. The injection of current and the discharge of energy from the magnetic circuit are both automatically regulated. Simultaneous three-phase OLTC dynamic resistance measurement and analysis, 3 x 10 A per phase Rapid core saturation for fast secondary winding test Total test current 10 mA - 36 A DC Resistance measurement range 0,1 - 2 k All 6 windings measured in one test Extremely quick measurement, the cable setup is performed only once Typical measurement accuracy of 0,1% Automatic discharge process Rapid automatic demagnetization AC current monitoring channel for tap changer motor current measurement Built-in tap changer control unit

Using two sets of four cables, all bushings of HV and LV sides are connected at once. The connection to the transformer is made with two-contact clamps providing for four-wire Kelvin test method.

Three-Phase Tap Changer Analysis Dynamic resistance graphs are recorded for all three phases simultaneously, so the synchronization is verified using the cursors provided in the DV-Win software. All three phase traces are plotted on the same graph. In addition, the tap changer motor current is recorded, and displayed on the same graph. The measurement is completed quickly even on the largest power transformers. Each vector group has a special measurement algorithm which is optimized for the fast stabilization of test results. Interchangeable Cables with the TRT63 Three - Phase Transformer Turns Ratio Testers The test cables used for the measurement are completely compatible with the DV Power TRT63 instruments. This enables the user to measure, with a single connection of the test leads: Transformer turns ratio Excitation current Phase angle Winding resistance in all tap positions Dynamic resistance in all on-load tap changer transitions On-load tap changer motor current On-load tap changer transition time in all transitions On-load tap changer transition ripples in all transitions Transformer vector group Automatic Three-Phase Demagnetization The TWA30D instrument can perform three-phase demagnetization after the DC test is finished. The process is completely safe, fully automated and very fast. This enables the user to avoid problems such as high inrush currents at the start-up of power transformers, incorrect operation of protective relays, erroneous diagnostics or inaccurate electrical measurement on a transformer.
www.dv-power.com 11

Transformer Test Equipment


On-Load Tap Changer Analysis with DV Power Instruments Due to their unique capabilities, the TWA30D and RMO-T series instruments are the best on-load tap changer analyzers in the market today. A tap changer analysis can be performed either by the stand-alone instruments, or in a combination with the DV-Win software. When used together with the DV-Win software, they enable the measurement of: Static resistance in all tap positions Dynamic resistance in all tap transitions On-load tap changer (OLTC) transition times in all tap transitions OLTC transition ripples in all tap transitions OLTC motor current The TWA30D instruments enable simultaneous OLTC testing of all three phases in a single pass through the tap positions. In this manner, the total OLTC testing time is greatly shortened, by two thirds in comparison with the classic methods. This test procedure also enables observing the synchronization problems between the different phases. The static resistance measurement provides winding resistance values on all tap positions for each of the three phases. There is no need to discharge the transformer between the measurements in different tap positions. The DV-Win software enables creating the static resistance graph from the results of the resistance measurement in different positions, as well as the automatic recalculation of the measured values to a reference temperature value. The shape of the static resistance graph depends on the winding regulation mode. The dynamic resistance measurement (DRM) feature enables measuring and recording of the test current at high sampling rate during the tap change transition. The variation of the current represents the change of the resistance in the circuit during the change of the tap positions. Tap changer verification can be performed in the DV-Win software or on the stand-alone TWA30D or RMO-T instruments. The stand-alone instruments detect any open circuits during the tap changer operation. The dynamic resistance measurement graph is unique, and above all, powerful tool that provides condition assessment of an OLTC regarding the mechanism itself and its contact wear. It is recorded by the DV-Win software. The innovative graph analysis tools enable the detection of: High resistance contacts in the tap selector Loose contacts in the tap selector Burned, loose contacts in the diverter switch Broken resistors in the diverter switch Abnormal arcing Misaligned contacts Contact bounce Mechanical and motor problems Phase synchronization problems The AC current monitoring channel enables monitoring and recording the OLTC mechanical-drive motor current during the tap changer operation. The motor-current waveform is also printed on the same DV-Win-generated graph, and can help in detecting OLTC mechanical problems. The OLTC transition times, as well as the percentage of a current drop during transitions (known as the transition ripples), are recorded numerically. The DV-Win software records these values in the Test Report together with the static winding resistance values. It is possible to save the Test Report in various formats, such as PDF, XLS, DOC, etc.

12

DV Power Products Catalog

Transformer Test Equipment


TRT Series Three-Phase Transformer Turns Ratio Testers
The TRT is a true three-phase, fully automatic test set, specially designed for a turns ratio, a phase shift and an excitation current measurement of power, distribution and instrument transformers. The TRT determines the transformer turns ratio by accurately measuring the voltages across the unloaded transformer windings. Following these measurements it displays the ratio of these voltages. All the TRT devices are equipped with a tap changer control unit which allows changing tap positions remotely. USB Flash Drive feature enables saving all the test results to a USB memory stick. DV Power provides 112 mm built-in thermal printer as an option. Main Features Ratio range 0,8 50 000 Test voltages 1 V to 250 V AC Measurement of turns ratio Measurement of phase shift Measurement of excitation current Vector group detection Built-in thermal printer Setting up the TRT is as simple as connecting it to de-energized transformer and entering the transformer configuration using the device front panel keyboard. Once the parameters are selected, the test of the three-phase transformer is performed in one of the two ways: SINGLE-PHASE Three single-phase voltages are applied to the three transformer primary windings, and all three phases are measured consecutively (phase by phase). All connections and short circuit procedures at the primary and secondary voltage terminals are automatic, done internally before each measurement, depending on the selected vector group. TRUE THREE-PHASE A true three-phase excitation voltage is applied to the three transformer primary windings. Three induced phase voltages are measured at the same time. In such a way it is possible to detect the phase angle and measure the turns ratio of any transformer type, including phase shifting transformers, where other three-phase turns ratio testers cannot. The TRT63 series is upgraded to use the same cable set as the Tap Changer & Winding Analyzer TWA30D, which enables a one-time cable setup. This makes TRT63 and TWA30D one combined measurement system.
Test voltage Single phase TRT03A 8/40/100 V AC TRT30A Single-phase True three-phase 8/40/100 V AC 3x(8/40/100)3 V AC TRT33A Single-phase True three-phase 1/8 /40/100 V AC 3x(1/8/40/100)3 V AC TRT63A Single-phase True three-phase 1/8/40/100/250 V AC 3x(1/8/40/100/250)3 V AC TRT03B 10/40/100 V AC TRT30B 10/40/100 V AC 3x(10/40/100)3 V AC TRT33B 1/10/40 /100 V AC 3x(1/10/40/100)3 V AC TRT63B 1/10/40/100/250 V AC 3x(1/10/40/100/250)3 V AC TRT03C 8/40/80 V AC TRT30C 8/40/80 V AC 3x(8/40/80)3 V AC TRT33C 1/8/40/80 V AC 3x(1/8/40/80)3 V AC TRT63C 1/8/40/80/250 V AC 3x(1/8/40/80/250)3 V AC www.dv-power.com 13

Transformer \ IPSUM LOREM LOREM IPSUMTest Equipment


DEM60C - Three-Phase Transformer Demagnetizers
The Three-Phase Transformer Demagnetizer DEM60C is lightweight instrument designed for single and three-phase transformer core demagnetization. The demagnetization process with DEM60C instrument is completely safe, fully automated and very fast. The instrument generates an alternating current applied with decreasing magnitude down to zero. This option is implemented by internally changing the polarity of a controlled DC current. Main features: Lightweight - only 13,1 kg Demagnetization currents 5 mA - 60 A DC Demagnetization process graph Fully automatic demagnetization Automatic discharging circuit DV-Win PC software

This powerful instrument generates a true DC ripple-free current of up to 60 A. High output currents enable an effective demagnetization even in case when there is no data of condition of the transformer core or previous tests. The new DEM60C instrument replaces the model DEM60, with an additional feature of displaying and monitoring the demagnetization process in real time. Supported by the DV-Win software, DEM60C enables current waveforms and values to be displayed during the demagnetization progress on the DV-Win generated graph. The graphical display of demagnetizing current in real time allows monitoring the transformer core demagnetization process. The generated graph can be saved on a computer. This option provides easy after-the-test analysis of the demagnetization process, in terms of current waveforms and values for each step, along with duration of the complete process.

Generator/Motor Test Equipment


RMO50M & RMO100M - Winding Ohmmeter
The Winding Ohmmeters RMO50M and RMO100M are designed for winding resistance measurement of motors and generators. Built-in discharging circuit is designed for energy discharge of motors and generators. Using DV-Win software a test can be performed from a PC and the results can be obtained directly at a PC. Main Features Lightweight - only 8 kg Test current 10 mA 100 A DC Measuring range 0,1 - 600 Extremely quick measurement Mechanical protection IP43
14 DV Power Products Catalog

Accessories and Software


Accessories - a Selection
Current cables 2 x 10 m 10 mm2 and Sense cables 2 x 10 m with TTA clamps Sense cables 2 x 10 m with TTA clamps Shunts

Digital rotary transducer with 5 m connection cable

Universal transducer mounting kit

Current clamp 30/300A with cable set 5 m

Transport Bags and cases

DV-Win Software
Features Full control of all DV Power instruments from a PC. Downloading the test results from the instrument. Acquisition and analysis of the test results The test results can be viewed, edited, saved, printed and exported. Viewing and overlaying several graphs, for an easy test result comparison. Selecting the measurement points and intervals using the two cursors. Zoom and pan graph feature. Specific test sequence setup. Customized configuration of the test result graphs. Creation of the predefined test plans for an easy and quick field testing.
www.dv-power.com 15

DISTRIBUTORS WORLDWIDE

IBEKO Power AB
Postal Address Box 1346 181 25 Liding Sweden Delivery Address Stockholmsvgen 18 181 33 Liding Sweden E-mail sales@dv-power.com support@dv-power.com Phone numbers Local support (Scandinavian): +46 8 731 78 24 International support: +46 70 0925 000 Fax: +46 8 731 77 99
DV Power Products Catalog

DISTRIBUTED BY

Вам также может понравиться