RC. 413243
Name & Address of the Owner of the Crane TRANSOCEAN SUPPORT SERVICES Name & Address of the Maker of the Crane MARATHON LETOUNNE MISISIPI USA Type of Crane & Source of Power PEDESTAL CRANE HYDRAULIC/ELECTRICAL Model No. Pedestal Height from Main Deck
AS Date of last previous test of Crane: 10-12-2012
Requested By:
Date of Examination
CHRIS CHINDAH
Date of manufacture of Crane NOT SEEN Type of Derricking Interlock LATTICE Maker Serial Number
10/12/2012
7.25m
Relevant Standard API RP 2D, ISO 4309-1990
PCM-120-AS-1408
10-12-2012 (i)
Length of jib (feet/mtrs)
Type of inspection:
(ii)
Boom Radius
(iii)
Boom Angle (Degrees)
(iv)
Test Load (Tonne)
(v)
S.W.L(Tonne)
Thorough Visual Examination MPI and Load Testing STATUS: FIT FOR USE AS AT THE
TIME OF INSPECTION
(feet/mtrs)
36.6m
40
78
27.4mT
21.95mT
In the case of a crane with a derrick jibs, the maximum angle at 0 which the jib may be worked. 80
Defects noted and alterations and repairs required before the Crane is put into service ( if none enter NONE)
(Parts of line) =
51.84 tons
SWL
Main Hoist Wire Rope (Construction, Size) Load Measuring Device: N/A LOCATION OF CRANE: PORT SIDE
(Parts of line) =
22.8 tons
SWL
INSPECTOR NAME/QUALIFICATTION:
ELVIS BASSEY LEEA, SNT LEVEL II MT, PT, UT, Lifting Equipment Insp.
Page 1 of 12
JC International Ltd.
A)
Inspect, measure wire rope with Venier caliper And record: Construction, Diameter, Type End, Orientation. BOOM LINE a) b) Nominal diameter of Boom Line: Measured Diameter of Boom Line: 22mm Rotation Resistance RLL 22mm None
Worst percentage of Wear Reduction at Different Section of Boom Line: Maximum Allowable: 10% = Defect which may impair continued use of this wire rope: Overall Assessment: c) d) Installed Date: Wire rope condition:
LOAD LINE e) f) Nominal diameter of Load line: Measured diameter of Load line: 25mm Rotation Resistance RLL 25mm None
Worst percentage of Wear Reduction at different sections of Load line: Maximum Allowable 10% = Defect which may impair continued use of this wire rope: Overall Assessment: Installed Date: g) Wire rope condition:
Page 2 of 12
JC International Ltd.
AUX. LINE h) i) Nominal diameter of Aux. line: Measured diameter of Aux line:
Worst percentage of Wear Reduction at different sections of Aux line: N/A Maximum Allowable 10% = Defect which may impair continued use of this ire rope: Overall Assessment: j) Installed Date:
k) l)
Wire rope condition: Pendant Line (R): Installed Date: 38mm 6XK36WS-1WRC(1-7-7+7-14)Szb(zn) March 26, 2009 38mm 6XK36WS-1WRC(1-7-7+7-14)Szb(z March 26, 2009
B)
CONDITION
COMMENTS
Good
N/A Good
d) Swivel Condition:
Good
e) Pin Condition:
Good
f)
Good
Marathon 25 Tons
Page 3 0f 12
JC International Ltd.
Parts enclosed
a) Number of Broken wires in one strand: b) Number of Broken wires in one lay: c) Numbers of Broken wires at the end fitting:
CONDITION Good
Yes
Good
d) Wedge Socket:
Good
2.
Aux line Hoist Drum: a) Rope properly reeved: b) Aux Hoist Rope Reeving: Number of parts:
N/A
c)
Aux Hoist Dead End Anchors Condition: d) Wedge Socket: 3. Boom Line Hoist Drum: a) Rope properly Reeved: Yes Reeving conform to manufacturers specifications
Page 4 0f 12
JC International Ltd.
Good
e) Wedge Socket:
D.
CONDITION Good
Good
c) Boom Length:
36.6m
d) Condition of Pins/keeper/Bolts:
Good
No wear on pins and Foot pins secured. Limit tested and functional
e) Boom Stop:
Good
f)
Number of Sections:
g) Hose/Cable Condition:
Good
i)
Good
j)
Good Good Good Good No contour on sheave No flange damage on sheave Free rotation of sheave and proper security
Page 5 0f 12
Functionally confirmed
JC International Ltd.
E.
CONDITION
COMMENTS
a) Housing condition:
Good
Handrails, Midrails, toe board and floors are all structurally good.
Good
Good
Handrails, midrail, toe board and floors are all structurally good Handrails, midrail, toe board and floors are all structurally good
Good
\\
F.
CONDITION OF CONTROLS a) Main Hoist control identified and operating properly: Yes - Proper markings and operations. - Controllers labeled to indicate their functions.
b)
Yes
c) d)
e)
Yes
JC International Ltd.
f)
Good
Tested for proper operation and ability to engage at proper boom angle.
g)
Good
Tested for proper operation and ability to engage at proper boom angle.
G a)
BRAKES Main Hydraulic hoist brake system: Good Automatic braking system No strange sound observed
b) c)
d)
Good
e)
Swing Ring: Slewing ring condition: Slew ring motor: Good Good No sound observed
OPERATORS CAB
CONDITION
COMMENTS
a) Operators manual:
Not seen
Good
Installed load chart is correct and kept in the crane operators cab. Displayed at strategic Lifting positions Installed, legible Verified, operating properly.
Good
Good
Page 7 of 12
JC International Ltd.
a) Control identification:
Good
Proper markings and operations and controllers labeled to indicate their functions. Functionally Tested
Good Good
Good Good Fully calibrated and functional COMMENT 100% MPI on the Accessible parts no Crack / corrosion was found
CONDITION Good
b)
Access ladders/step:
Good
Page 8 of 12
JC International Ltd.
JC International Limited
RC. 413243
GENERAL
CONDITIONS Good
b)
Good
c)
Safety System:
Good
d) e)
Good Good
f)
Angle Indicator:
Good
g)
Load Indicator:
Good
h)
Good
i)
Load Chart:
Good
j)
Control Identification:
Good
k)
Fire Extinguishers:
Good
l)
Good
m)
Good
n)
Good
o) p)
None Good
Page 10 0f 12
JC International Ltd.
Page 11 of 12
JC International Ltd.
Page 12 of 12
JC International Ltd.
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Description of Equipment
Magnetic Particle Inspection On the Boom line wedge socket. Magnetic Particle Inspection Main line Wedge Socket Magnetic Particle Inspection on the Main line dead end anchor point
PARTS EXAMINED: Welded joints and load bearing areas RESULTS: No defect as at the time of inspection
Name and address of equipment owner: Transocean Support Services Port Harcourt.
We hereby certify that on 10/12/2012(date) no defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: ELVIS BASSEY Conducting: Examination only
JC International Ltd.
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Description of Equipment
Magnetic Particle Inspection On the Boom line termination. Magnetic Particle Inspection on the accessible welded parts of the Pedestal
PARTS EXAMINED: Welded joints and load bearing areas RESULTS: No defect as at the time of inspection
Name and address of equipment owner: Transocean Support Services Port Harcourt.
We hereby certify that on 10/12/2012(date) no defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: ELVIS BASSEY Conducting: Examination only
Revision No: 01
JC International Ltd.
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
Description of Equipment
Magnetic Particle Inspection on the Entire body . of the Main and Auxiliary Block Hook.
PARTS EXAMINED: Welded joints and load bearing areas RESULTS: No defect as at the time of inspection
Name and address of equipment owner: Transocean Support Services Port Harcourt.
We hereby certify that on 10/12/2012(date) no defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: ELVIS BASSEY Conducting: Examination only
Revision No: 01
JC International Ltd.
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
TEST CERTIFICATE
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Equipment Description: Client: Inspection Location: Boom Type: Crane Manufacture: Model Number: Serial Number: Customer Unit Number: SWL @ 78o / 40ft: Tested to: Certificate Number: Inspection Date: Next Date of Examination: Next Date of Test:
OFFSHORE CRANE TRANSOCEAN SUPPORT SERVICES HI 7 LATTICE MARATHON LETOUNNE USA AS PCM-120-AS-1408 N/A 21.95mT 27.4 mT @ 40ft 87612 10/12/2012 09/06/2013 09/12/2013
This is to certify that I did, Test/Examination on the Offshore Crane in accordance with API RP 2D, ISO 4309-1990 and all Statutory requirement as above. The records of examination are true without prejudice for the purpose it was designed for. FIT FOR USE for Main Hoist Line Only.
Inspectors Name/Qualification Signature/Date
ELVIS BASSEY
LEEA, FID, SNT LEVEL II MT, PT, UT Lifting Equipment Insp. 10/12/2012
JC International Ltd.
JC International Limited
RC. 413243
JC International Ltd.
JC International Limited
RC. 413243
Picture Showing 100% MPI carried out on boom line termination on A Frame
JC International Ltd.
JC International Limited
RC. 413243
Picture Showing Proper Evaluation of Wire Rope on the boom fly sheave area
Picture Showing 100% MPI conducted on the swivel and wedge socket on main line end termination
Picture Showing reading of test at SWL of Crane and dynamic application on Crane
JC International Ltd.
JC International Limited
RC. 413243
Evidence of MPI Conducted On Crane Main Line Dead End Termination points
JC International Ltd.
JC International Limited
RC. 413243
Picture showing proper wire rope reeving on main and boom line drums
JC International Ltd.