Canalis KTA from 800 to 4000 A For horizontal transport and distribution
Tap-off units
b Canalis KS plug-on tap-off units are compatible with the Canalis KT busbar trunking: v protection by 25 to 400 A fuses, v protection by 100 to 400 A Compact NS circuit breakers. b Canalis KT xed tap-off units: v protection by 400 to 1000 A Compact NS circuit breakers.
PD202314 PD202315

Canalis KTA Run sections


b b v v b v b Rating: 800 to 4000 A. Transport sections: xed lengths: 2 and 4 meters, non-standard lengths: 0.5 and 3 meters, Distribution sections: xed lengths: 2 and 4 meters, Adjustable lengths 1.10 to 1.50 meters.

Change-of-direction sections
b Change-of-direction sections adapt to all busbar trunking requirements. b There are both xed and made-tomeasure lengths.

Presentation
PD202328 PD202312

PD202313

36

Schneider Electric

K9AE11500

Presentation

Canalis KTA from 800 to 4000 A For horizontal transport and distribution
Universal supply connections
b Supply connections allow the busbar trunking to be connected to the switchboards busbar or to the transformer.

Canalis KTA Interface connections


b Pre-fabricated interfaces connections can be incorporated into: v Prisma Plus and Okken switchboards, v France Transfo dry-type transformers.

Horizontal xing supports


b There are two types of support for installing the busbar trunking horizontally. b One type of xing: to x the busbar trunking to its support.

PD202431

PD202317

PD202318

K9AE11500

Schneider Electric

37

PD202300

Presentation

Presentation

Canalis KTA from 800 to 4000 A For distribution to different levels


Rising mains

Canalis KTA Run sections

b Rating: 800 to 4000 A. b Distribution sections, xed 2 meter lengths. b Transport sections for going through oor slabs, xed 0.5 to 3 meter lengths.
PD202320 PD202319

Presentation
b For installing the busbar trunking vertically, they ensure: v height and depth adjustment, v load sharing, v absorption of expansions, vibrations, etc. b They can be xed either to the oor, the wall or to a bracket.
PD202321

Vertical xing support

b Canalis KS tap-off units are compatible with the Canalis KT busbar trunking: v protection by 25 to 400 A fuses, v protection by 100 to 400 A Compact NS circuit breakers. b Canalis KT xed tap-off units: v protection by 400 to 1000 A Compact NS circuit breakers.
PD202322

Tap-off units

38

Schneider Electric

K9AE11500

Presentation

Tap-off units from 25 to 1000 A

Canalis KTA Rating (A) Type of protection

Modular switchgear

Compact NS

Fuses

Compact NS with measurement and metering

Plug-on tap-off units


PD202149 PD202150 PD202138

25 to 100

63 A, 8 x 18 mm modules
PD202148

25 / 50 A for NF / DIN fuses 32 A for BS fuses For Compact NS100 circuit breaker
PD202147

100 A, 12 x 18 mm modules 63 A for DIN fuses 100 A for NF / DIN fuses 80 A for BS fuses
PD202150 PD202150 PD202323

160

For NG125 / 160 circuit breaker For Compact NS160 circuit breaker 160 A for NF / DIN / BS fuses
PD202324 PD202184

250 to 400

Fitted with DIN rail for Powerlogic PM810


PD202324

For Compact NS250 circuit breaker


PD202325

For Compact NS250 circuit breaker 250 / 400 A for NF / DIN fuses
PD202325

For Compact NS400 circuit breaker For Compact NS400 circuit breaker

Fixed tap-off units


PD202326

400 and 630

For Compact NS400 and NS630 circuit breaker


PD202327

800 and 1000

For Compact NS800 and NS1000 circuit breaker

K9AE11500

Schneider Electric

39

Presentation

Description

General

Canalis KTA
The Canalis KT busbar trunking is intended for high power distribution and transport in industrial, commercial and tertiary buildings. Assembly of prefabricated sections that adapt to all run congurations.

Run sections
b b b b b b
3L + PE
DD202435-m

8 ratings are available, from 800 to 4000 A. 4 aluminium live conductors with identical cross-sections (3L + N + PE version). Conductors insulated using polyester lm, class B 130 C, halogen free. Standard busbar trunking is IP55. Insulation voltage: 1000 Volts. Available polarities: 3L + PE, 3L + N +PE, 3L + N + PER (reinforced PE)

DD202434-m

DD202387

Description

The KT busbar trunking is of compact design and can be installed edgewise, at or vertically. This design, allows the busbar trunking to be installed through a oor slab or re barrier wall. As standard, the Canalis KT busbar trunking acts as a re barrier in accordance with IEC 60439-2 The RAL 9001 pre-lacquered galvanized steel casing provides protection and mechanical xing of the conductors. Further, it is used as the PE protective conductor (in accordance with NFC 15100 and IEC 60364). In its reinforced version 3L + N + PER, the busbar trunking is tted with an additional internal conductor with a cross-section equal to half that of the phase conductor. This version also has lateral reinforcements to allow high short-circuit currents (Isc) to be supported. The Canalis KT busbar trunking is suitable for applications containing harmonics by taking into account the appropriate derating factor. See Harmonic currents in the Design guide.

3L + N + PE The conductors are sandwiched together inside the metal casing.


DD202436-m DD202388

3L + N + PER

Tap-off contact
The KS plug-on tap-off units are connected to the busbar trunking whilst live (offload) via spring jaw connections. Contact zone coating: b silver-plated copper at jaw contact points, b aluminium / silver-plated copper bimetallic saddle welded to the live conductors.
The electrical contact pads of the sections are made from bonded bimetallic aluminium / copper.
DD202498

Joint block
The junction between sections is made using a joint block. The joint block provides the following: b electrical junction between live conductors and between PE protective conductors, mechanical link between the two sections. It provides simultaneous continuity between all conductors. It is tightened using torque bolt(s) (1 to 4 depending on the rating) with snap-off heads. The nut head snaps-off, freeing a red washer, when the correct tightening torque is reached. This operation is checked visually: b if the red washer is absent: it has been tightened, b if the red washer is visible: it has not been tightened. This device guarantees the necessary contact pressure between live conductors and is operator independent. For dismantling or maintenance operations, the nut has a second head. The tightening torque is 6 daN.m. All sections (apart from ER and EL feed units) are supplied with their joint block, delivered in a separate parcel. If the run has a feed unit (ER or EL) at each end, an additional joint block must be ordered.
DD202389 DD202445

Schneider Electric

K9AE12000

Description

Run sections

Canalis KTA Straight sections Transport sections - Type ET


Transport the current without tap-off points. Available in 2 and 4 metre xed lengths or made to measure from 0.50 to 3 metres.
DD202390

Adjustable section - Type AJ

Compensates for dimensional differences in the installation. Adjustable length from 1.10 to 1.50 metres.
DD202483

Sections with tap-off points for plug-on tap-off units Type ED


ED run sections are for current distribution. They use 25 to 400 A KS tap-off units. These tap-off units can be plugged-on whilst live, but off-load. Available in xed 2 or 4 metre lengths with 3 tap-off points on one side.
DD202438

Sections with tap-off points for xed tap-off units - Type EB

EB run sections are for current distribution. They use specic KT 400 to 1000 A tap-off units. These tap-off units can only be tted / removed when the run is not energised. Available in a 2 metre xed length with one tap-off point or a 4 metre xed length with 2 tap-off points.

K9AE12000

DD202437

Schneider Electric

Description

Description

Other run sections Disconnectors and run protective devices

Canalis KTA Other run sections


DD202446

Expansion section - Type DB

It controls and absorbs the expansion of Canalis runs and must be used on runs over 30 metres and each time the busbar trunking passes through a building expansion joint. Refer to the installation guide. Available in a 1 metre length, it can be tted vertically or horizontally. At its centre it has exible conductor joints and a sliding case able to absorb the relative movements of each part of the section.

Transposition sections - Types TN, TP Description


DD202439

Used when the phase order of the switchboard is different to that of the transformer. Available in a 1 metre length and is the same physical size as a transport section. b The TN version transposes the neutral.
DD202391

b The TP type transposes the phases.


DD202392 DD210811A DD210813

Additional joint block - Type YA

If the run has a feed unit (supplied without a joint block) at each end, an additional joint block must be ordered. Each joint block is supplied with the necessary covers, nuts and bolts.

Run end cover - Type FA

The end cover protects and insulates the conductor ends and is tted to the last section.

Disconnectors and run protective devices


Fitted between 2 at or edgewise sections, they isolate or protect a busbar trunking part run. Each assembly is supplied tted with a 3 or 4-pole device complete with rotary handle. Supplied with: b an auxiliary connection terminal, b lifting rings, b upstream and downstream terminal shields. Colour: white RAL 9001, 100 % polyester paint on galvanized sheet steel. Refer to manufacturers data for switchgear characteristics. Fitted with a rotary handle, the tap-off unit can only be opened once the device has been switched off.
DD202440 DD202441

Run disconnector tap-off units - Type SL

Type SL for: b Compact NS 1000 to 1600 A type NA xed isolators: v unhingeable door, v 3-point closing (possibility of locking with key lock, not supplied), b Interpact INV isolator, 2000 to 2500 A: v unhingeable door, v 3-point closing (possibility of locking with key lock, not supplied), b Masterpact NW 3200 A type HA xed isolator supplied with: v transparent protection cover, v adaptation kit for Ronis lock + 1 Ronis lock, v complete Harting plug, not cabled.

Run protection tap-off units - Type PL

Type PL for: b Compact NS 1000 to 1600 A type N xed circuit-breakers: v unhingeable door, v 3-point closing (possibility of locking with key lock, not supplied). For circuit-breakers greater than 1600 A, consult the sales ofce.

Schneider Electric

K9AE12000

Description

Change of direction sections

Canalis KTA Simple changes of direction Elbows - Types LP and LC


DD202393

To go up or down, to turn right or left: b type LP, at elbow available in xed or made-to-measure lengths,

b type LPpC, at made-to-measure angled elbow,


DD202432

b type LC, edgewise elbow available in xed or made-to-measure lengths,


DD202394

b type LCpC, edgewise made-to-measure angled elbow.


DD202433

Edgewise T junctions - Type TC


DD202395

To feed runs perpendicular to the main run.

Changes of direction Zeds - Types ZP, ZC and CP


3-branch made-to-measure: b at or edgewise, to move the run axis upwards, downwards, to the right or to the left without having to bend the busbar trunking: v type ZP, at Zed,
DD202396

v type ZC, edgewise Zed,


DD202397

b edgewise / at, to provide the busbar trunking with a bend: v Type CP, edgewise and/or at Zed.
DD202398

K9AE12000

Schneider Electric

Description

Description

Connection sections

Canalis KTA
To connect the KTA busbar trunking to different terminals or to transformer, switchboard, generator set, etc. busbars. Canalis offers high performance connection sections which meet all requirements. These sections provide installation exibility combined with quick and simple assembly. Further, the connections are made using torque bolts which provide both ease of installation (use of a standard spanner for tightening to 6 daN.m) and a visual check before energising.

Connections via interface to Prisma Plus, Okken and Trihal


Direct connection to Trihal transformers and Prisma Plus & Okken switchboards. Supplied factory or panelbuilder assembled and tested to IEC 60439-1 and 2. Quick and simple connection of the busbar trunking to the interface. Reduced size. Joint block integrated into the interface. A sealing kit (rating dependent) must be ordered.
DD202314 DD202306

Description

Sealing kit

Prisma Plus and Okken switchboards

For xed or draw-out incoming device, front or rear connection: b Masterpact NW08 to NW40 or NT06 to NT16 circuit-breaker, b Compact NS630b to NS1600 circuit-breaker.
Prisma Plus switchboard
DD202310

Possibility of switching the phases around.

Okken switchboard

Schneider Electric

K9AE12000

Description

Connection sections

Canalis KTA
DD202503

France Transfo Trihal dry type transformers


For naturally ventilated or force ventilated transformers. Protection degree: b IP00, b IP31. Secondary voltage: 410 V 15 mm adjustment in the 3 axes.

K9AE12000

Schneider Electric

Description

Description

Connection sections

Canalis KTA Universal connections to switchboards and oil immersed transformers


DD210777

Feed units - Type ER

They allow the busbar trunking to be connected to a switchboards busbar, or to the terminals of an oil immersed transformer, generator set, etc. They come complete with a mounting plate tted: b either directly to the roof of the switchboard, b or via the intermediary of a protective cover. Vertical or horizontal incoming busbar trunking.
DD202399

Description

Types ER N1/N2

Types ER N3/N4

Types ER N5/N6

Type ER N7

Connection: b either directly to the busbar, b or by exible bars and connection plates, b or by braids, b or by cables. b ER feed units are supplied without a joint block. b If the run has a feed unit at each end, an additional joint block must be ordered.

DD202502

Schneider Electric

K9AE12000

Description

Connection sections

Canalis KTA Protective covers - Types CS, CR, BC


Protects the external part of the connection. b Type CS Height adaptable exible protective cover adaptable for ER N1 to N6 feed units with a between centres distance of 115 mm.

10276 -03-d1

For a vertical incomer - Types CR1 to CR3

Made-to-measure rigid protective cover for ER N1 to N7 feed units. They are height adjustable by 50 mm. b Type CR 1 for a horizontal incomer.
DD205623

b Types CR2 and CR3 for a vertical incomer.


10276-3 03-d4 DD205624

b Types CR7 and CR8 Protective covers for oil immersed transformers. Only for ER N1 to N6 feed units with a between centres distance of 150 or 170 mm depending on the rating. Fit directly onto the BT series transformer tanks Never use with HV porcelaine bushings. v Type CR7 for a vertical incomer.
DD202321

v Type CR8 for a horizontal incomer.


DD202325

v Type BC Protective cover for direct cable connection to ER N1 to N6 feed units with a between centres distance of 115 mm. K9AE12000

Schneider Electric

Description

Description

Connection sections

Canalis KTA Universal connections to dry type transformers


DD202447

Feed units - Type EL

For dry type transformers with the neutral between the phases. They allow optimum connection to the busbar trunking. The junction with the busbar trunking is achieved: b either from the side,
DD202442

Description

Type EL N1/N2

b or from the centre.


DD202443 DD202444

Type EL N3/N4
DD202448

Type EL N5

They are of similar design to straight transport sections and can be installed edgewise or at. If installed at, a set of angle brackets can be ordered. The following must be specied at the time of order: phase order, distance between phases (a 20 mm lateral adjustment can be made use of on site). The link between the transformer terminals and the connection section is either by exible bar connection plates or by braids.

10

Schneider Electric

K9AE12000

Description

Connection sections

Canalis KTA Protective covers - Type CR4 to CR6


These protect the connections with an IP31 casing when connecting to a transformer. They are height adjustable by 50 mm. b Type CR4 Protective cover for EL N1 to N4 feed units. Edgewise assembly.
DD202342

b Type CR5 Protective cover for EL N1 to N4 feed units. Flat assembly.


DD202343

b Type CR6 Protective cover for EL N5 feed unit. Edgewise assembly.


DD202346

K9AE12000

Schneider Electric

11

Description

Description

Connection accessories

Canalis KTA Accessories for direct connection to the switchboard


The conductors of ER N1 to N6 feed units are connected directly to the switchboard busbars. YB2 copper spacers are available to compensate differences in thickness between the switchboard bars (10 mm) and the connection part (6 mm). Make-up of kit: b 8 x 2 mm thick copper spacers, b 16 off M12 x 60 mm bolts, class 8.8, b 16 contact washers, b 16 torque nuts, b 8 steel spacer plates. Order a set per feed unit whatever the rating.
DD202400 DD202410 DD202363

Description

Switchboard connection accessories using connection plates


The conductors of ER N1 to N6 feed units are connected via connection plates to the switchboard busbars. The YC types are exible bars made up of 5 copper sheets of 1 x 100 mm (500 mm cross-section). The number of connection plates needed is proportional to the busbar trunking rating. There are 3 types: b YC1, uninsulated 600 mm long bar with 4 oblong holes at one end. The length of the holes at the switchboard side are to be adapted on-site,
104202DD DD210784

b YC2, uninsulated bar, made-to-measure length of 250 to 600 mm with 4 oblong holes at each end, ready to use,
DD202402

b YC5, insulated 1000 mm long exible bar, stripped at one end and with 4 oblong holes. The length of the holes at the switchboard side are to be adapted on-site.
DD202403

Nuts and bolts The connection plates are xed to the feed unit using the YB3 nut and bolt kit, made up of: b 16 off M12 x 60 mm bolts, class 8.8, b 16 contact washers b 16 torque nuts, b 8 steel spacer plates. Clamps YS1 clamps enable high short-circuit current levels to be withstood; only for bars with a 115 mm spacing.
DD202411

DD202478

Insulation A YF sheath is available to insulate the phases from one another. It can be tted to the YC1 and YC2 connection plates once they have been connected.

12

Schneider Electric

K9AE12000

Description

Connection accessories

Canalis KTA Transformer connections - Types YC, YT


The feed unit conductors are connected to the transformer bars via connection plates or braids: b connection plates, YC types, are exible bars made up of 5 copper sheets of 1 x 100 mm (500 mm cross-section). b braids, YT type, are copper braids with a 600 mm cross-section. The number of connection plates needed is proportional to the busbar trunking rating.
DD202450

Connection plates

YS2 and YS3 bar clamps enable connection without the need to drill the connection plates. They allow height adjustment. b Type YS2, bar clamps for 100 mm transformer connection terminals. b Type YS3, bar clamps for 120 mm transformer connection terminals. Make-up of kit: 1 set of 8 parts.
DD202413

b The YC4 is an uninsulated bar with an expansion kink; it is 400 mm long and has 4 oblong holes at each end (ready to use).
DD202414

Braids
DD202415

Type YT, 400 mm long insulated braid with 4 holes at each end.

The connection plates and braids are xed to the feed unit using the YB4 nut and bolt kit, made up of: b 16 off M12 x 80 mm bolts, class 8.8, b 16 contact washers, b 16 torque nuts, b 8 steel spacer plates.

K9AE12000

Schneider Electric

13

Description

The YC3 is an uninsulated bar with an expansion kink; it is 400 mm long and has 4 holes at one end. They can be tted to the transformer side: b either using bar clamps (no drilling), b or drilled and bolted (to be carried out on site).
DD202412

Description

Supports and fixings

Canalis KTA Horizontal supports


The ZA types allow the busbar trunking to be xed and adjusted along its length, as well as absorbing its movements.
2 7 3 2 0 2DD

Supports for horizontal sections

b Type ZA1, to support edgewise busbar trunking only, consists of a steel angle bracket and 2 x 1.2 metre threaded M10 rods. The maximum distance between supports is: v 3 metres for edgewise busbar trunking, v 2 metres for at busbar trunking. See installation precautions.
DD202485

Description

b Type ZA4, to support the busbar trunking from the top. b These supports are needed to x edgewise EL N1 to N4 feed units for dry type transformers.
DD202368 DD202486

DD202369

Fixing bracket
DD202484

The ZA3 keeps the busbar trunking in place on its support, without blocking it, in order to allow expansion movements.

Vertical supports
The ZA5 is for supporting vertical sections. They x sections of a vertical run to the buildings structure. This type of xing support has the following advantages: b assembly: v to a wall, v to a wall bracket, v to the oor, b height and depth adjustment, b spring adjustment to ensure distribution of the load at each oor, b avoids the transmission of building forces to the busbar trunking (expansion and vibration).
DD202496 DD202374

For KTA08 to KTA16.

For KTA20 to KTA40.

To a wall.

To a wall bracket.

To the oor.

14

Schneider Electric

K9AE12000

Description

Tap-off units

Canalis KTA
The tap-off units are used to instantly connect loads or secondary runs, and comply with installation standards and regulations (IEC 60364), whatever the earthing system (TT, TNS, TNC or IT). When off-load, they can be plugged-on and off and be operated whilst live. Plugging-on and plugging-off automatically opens and closes the tap-off point.
DD210275

Description

No live part is accessible with the door open. The protection degree is IPXXB (nger protection). They are IP55 by construction (no accessory is required).
DD210276

Safety and operation

Fuse and modular switchgear tap-off units (AC22 to AC20) are isolated as soon as the tap-off unit door is opened. Tap-off unit disconnection by opening or closing the cover should be carried out only if the downstreamload is de-energised. For circuit breaker tap-off units, there are safety mechanisms to prevent: b the tap-off unit being plugged-on and plugged-off with the tap-off unit door closed, b the door being closed if the tap-off unit has not been locked onto the busbar trunking, b access to the electrical equipment and connection terminals when live, b the door being opened in the ON position for tap-off units tted with a Compact NS or NG circuit breaker. These tap-off units can be tted with accessories such as: b door early break contacts, b adapter for lead sealing, b etc. The sheet steel tap-off units are tted with a carrying handle. Characteristics of tap-off units up to 100 A b Colour: v white (RAL 9001) body and carrying handles, v transparent green door (similar design to the Kaedra enclosures). b Material: self-extinguishing, halogen-free insulating plastic (re resistant and very high temperature withstand). Other characteristics: cable gland drilling zone, stainless steel screws and the door can be lead sealed. Characteristics of tap-off units from 160 to 400 A b Colour: v white (RAL 9001) body, v black carrying handles (RAL 9005), v 100 % polyester paint. b Material: galvanized sheet steel. Other characteristics: b unhingeable door (120 opening hinges), b vertically bevelled polyurethane seals with a double fold for increased rigidity (similar design to the Sarel Spatial 3D enclosures), b 25 mm grill type gland plates for a maximum access area.

DD202012

DD210466

Schneider Electric

K9AE13000

Description

Plug-on tap-off units for circuit breakers

Canalis KTA
DD210454

Isolator tap-off units for modular switchgear

Most 18 mm Multi 9 modular devices can be tted into these tap-off units. They have a window on the front face for switchgear control and visualisation. A transparent shutter ensures the window can be sealed. Two tap-off ratings are available: b 63 A nominal current for 8 modules, b 100 A nominal current for 12 modules (accepts C120 circuit breakers).

Isolator tap-off units for Compact NS circuit breakers


DD210461

These tap-off units are tted with mounting plates and upstream connections for xed, front-connected 100 to 400 A Compact NS circuit breakers (N, H or L version) with a rotary handle. The 400 A tap-off units can only be tted onto straight lengths with a rating greater than 400 A. For plug-on circuit breakers, Vigi units, etc, please consult your Schneider Electric contact.

Measurement and metering isolator tap-off units


DD210465

These tap-off units allow sub-metering to re-allocate power consumption costs by consumer and to monitor installations by, for example, following run load levels. The values measured using the Compact NS TI unit are sent to the measurement unit which then sends the information to a central unit via a bus (see Measurement and metering). They are tted with: b a mounting plate for a Compact NS 250 or 400 A circuit breaker with an extended rotary handle and a Compact NS current transformer module (TI unit), b a DIN rail for installing a Powerlogic PM810 measurement unit, a set of terminals, etc. In severe operating conditions (> 40C ambient temperature), we recommend the use of a PM810 without display.

K9AE13000

Schneider Electric

Description

Tap-off units for NG type modular switchgear


DD202154

These tap-off units are tted with a DIN rail and upstream connections for 18 mm wide modular devices. The switchgear is operated via a rotary handle which prevents door opening when the circuit breaker is in the ON position. Nominal current: 160 A for a 13-module capacity (accepts NG125 or NG160 tted with a Vigi unit).

Description

Plug-on tap-off units for fuses

Canalis KTA
These tap-off units provide the tap-offs with fuse protection (fuses not supplied).

Plastic tap-off units


DD210466

Fitted with carriers for: b 50 to 100 A cylindrical NF fuses, b 25 to 63 A DIN screwed fuses, b 100 A DIN blade fuses, b 32 to 80 A BS screwed fuses.

Description

Steel tap-off units


DD202012

Fitted with carriers for: b 160 to 400 A NF / DIN blade fuses, b 160 A BS screwed fuses.

DD210472

Schneider Electric

K9AE13000

Description

Fixed tap-off units for circuit breakers

Canalis KTA Safety and operation


The electrical connection is made by plugging-on the tap-off unit into dedicated tapoff point whilst the busbar trunking is de-energised (plugging-off the unit must also be done with the busbar trunking de-energised). The connection is mechanically tightened using a one-use torque bolt (10 daN.m). A mechanical foolproof system avoids the risk of incorrect assembly. The door can only be opened once the load has been isolated (rotary handle). The bolt can only be tightened or untightened with the door open. No live part is accessible with the door open, protection degree IP2X.

Characteristics of tap-off units from 400 to 1000 A

b Colour: v white (RAL 9001) body, b Material: galvanized sheet steel. b Other characteristics: v the cables exit laterally through 2 aluminium plates (to be drilled by the installation contractor), v cabling space can be increased by using the cable box supplied with the tap-off unit, v the door is xed using 6 captive M6 screws and can be completely removed to facilitate cabling.

DD202451

Steel tap-off units

These tap-off units are used to supply loads or secondary runs (e.g. medium power distribution using Canalis KS). They are tted to specic EB type straight lengths. They comply with installation standards and regulations, whatever the earthing system (TT, IT, TNS or TNC): b tap-off units tted with a mounting plate for Compact NS400/1000 A, 3 or 4 P: v xed device, v front connections, v extended rotary handle. 2 models: b Compact NS400/630 A, connection capacity: v 3 x 300 mm2 cables for the phases and neutral (hole diameter = 15 mm), v 150 mm for the PE, b Compact NS800/1000 A, connection capacity: v 4 x 300 mm2 cables for the phases and neutral (hole diameter = 15 mm), v 200 mm2 for the PE (cable clamp). The standard tap-off unit is IP54.

DD202497

K9AE13000

Schneider Electric

Description