PROFESSIONAL

EGGER CONSTRUCTION
Wood based panels for use in timber construction

www.egger.com

Architects, Joiners and Home owners appreciate the beauty, exability and advantages of using wood as a building material. Engineered wood products made by EGGER full these expectations.

EGGER CONSTRUCTION MORE FROM WOOD WITH A TOTAL OF 17 PLANTS, EGGER RANKS AMONGST THE LEADING PRODUCERS OF WOOD-BASED MATERIALS IN EUROPE.
The EGGER group has made it their mission to provide durable wood-based products and solutions with lasting value for the construction and interior design industries. Our wood based products are the ideal answer for construction and decorative applications. Their special characteristics allow you to plan and carry out work of the highest quality with condence. EGGER carefully selects its raw materials and uses state-of-the-art technology to give its high-quality wood-based materials a new dimension. This fulfills two market requirements: Technical construction material with certified performance potential, which meets all the requirements of CE-marked construction products. Certified environmentally-friendly wood-based materials e.g. with IBU environmental product declaration in accordance with ISO 14025. Our plant in Wismar, Germany has been certified in accordance with ISO 9001 since 2001. Chain-of-custody certificates are available for the PEFC and FSC systems. EGGER is a global supplier of tested and certified wood construction products along with an array of other applications, satisfying system solutions for planners, architects and fabricators. Committed employees with sales and technical advice are on hand to provide support for our customers projects.

03

EGGER wood-based panels satisfy the needs of the customer through high quality, application-optimised panel sizes and by our product experts and logistics service.

04

EGGER WOOD CONSTRUCTION


EXTERIOR WALL WITH 3 FUNCTIONS As well as providing reinforcement, EUROSTRAND OSB also acts as a vapour barrier (sd-value > 2.0 m). In vapour permeable constructions, there is no need to invest extra labour on installing a vapour barrier. The OSB-layer also provides a sucient degree of airtightness on patched joints, installations and permeations. EGGER DHF is used on the outside of walls as an external diusion-open (sd-value < 0.2 m) and windproof layer behind a ventilated facade. This protects the structure during the construction phase, allowing interior work to proceed to schedule. Thermal insulation and sound insulation will be clearly improved compared to a vapor permeable cladding with breather membranes.

1. Plaster boards 2. Insulated service cavity 3. EUROSTRAND OSB 4 TOP 15 mm


1 2 3 4 5 7

4. Cellulose insulation 5. EGGER DHF 15 mm 6. Vertical lathing 7. Weatherboarding

1. Plaster boards 2. EUROSTRAND OSB 4 TOP 15 mm

Benets on a view
1 2 3 4 6

3. Cellulose insulation 4. EGGER DHF or woodbre insulation board 5. Horizontal lathing 6. Larch wood planking

vapour permeable construction with EUROSTRAND OSB as interior vapour control layer easy to make air tight storey-high sheathing high loadbearing capacity

FACADE SYSTEMS THE CHOICE IS YOURS We have a variety of interesting cladding options for you to choose from. From the modern thermal insulation composite systems (TICS), with a classic rendered facade or a quarter-brick eect, through curtain wall facades to the popular wooden facades in the form of laths, planks or shingling. You can have any colour or type you wish. Even demanding architectural requirements can be fullled using these systems.
TICS (e.g. StoTherm Classic)

INTERNAL WALL Its superb technical properties and varied formats even with tongue and groove prole make EUROSTRAND OSB ideal for use in internal walls. With EUROSTRAND OSB it is easy to attach loads such as cupboards or shelves to the wall surfaces without requiring special dowels. Another advantage of EUROSTRAND OSB 4 TOP is that it gives you the option of reducing the distances between the nail and the edge of the board in question. This allows the wood cross section of the loadbearing structure to be optimised and thereby reduces the heat loss through the wooden supporting structure.

Benets on a view
Brick cladding with air space easy handling improved noise control fastening with staples, nails and screws suitable for hanging shelves

05

CEILING AND FLOOR CONSTRUCTIONS The quality of living spaces depends on the quality of the sound insulation. A well planned construction can prevent any undesired inuences and disturbances. The minimum requirements are set out in the relevant standards. Additional sound proong requirements must be specially agreed with the developer.

Note
Sound insulation products for the use in timber oors provide an acoustic impedance refered to length of r > 5 kN s/m

DETACHED HOUSE 1ST FLOOR WITH BASIC REQUIREMENTS


1. EUROSTRAND OSB 4 TOP 18 mm 2. Impact sound insulation board 3. Concrete blocks 4. EUROSTRAND OSB 4 TOP 22 mm 5. Still air layer 6. Mineral bre 040 7. Cross joists 8. Plaster boards 12.5 mm
4 5 3 1

CONSTRUCTION WITH ADVANCED REQUIREMENTS APARTMENT BUILDING


1. EUROSTRAND OSB 4 TOP 22 mm 2. Mineral bre 040 3. Expanded perlite lling 4. Sisalit 30 trickle protection 5. EUROSTRAND OSB 4 TOP 22 mm 6. Still air layer 7. Mineral bre 040 8. Resilient channel 9. Plaster boards 12.5 mm
4 6 1

2 3 5

Benets on a view
At a centre-to-centre span greater than 62.5 cm (i.e. reconstruction of old buildings) for a re resistance of 30 minutes EUROSTRAND OSB 4 TOP, 30 mm, T&G2, size 3000 1250 mm is recommended.

06

FLOATING FLOOR WITH EGGER DFF AND EUROSTRAND OSB With a measured reduction in impact noise Ln,w = 20 dB in solid ceilings in accordance with DIN EN ISO 140-8 and excellent Ln,w = 7 dB in wood-beam ceilings following DIN EN ISO 140-11, suitable wood bre insulation board, in conjunction with 15/18 mm OSB ooring boards, are also suitable for oating oor systems on new builds, restorations and renovations. Here the circumferential tongue and groove prole allows for easy, tight, installation of the boards for uniformly high sound protection.

FLOATING FLOOR WITH EUROSTRAND OSB


1. Floor covering 2. EUROSTRAND OSB 4 TOP 18 mm 3. Woodbre insulation board 4. Floor load (e.g. footpath agstones) 5. Structural ceiling
1 2 3 4

FULLY-INSULATED PITCHED ROOF Of all construction elements, the roof is the most exposed to weather and environmental inuences. Its design and construction are therefore of particular importance. EGGER oers system solutions for this eld of application. EGGER DHF is perfect for additional structural and re protection requirements. Use of loft space as living quarters places whole new demands on roofs. Requirements such as summer overheating protection, thermal insulation in the winter, as well as appropriate sound proong and re protection can easily be met.

MODERN ROOF STRUCTURE WITH EGGER EUROSTRAND OSB 4 TOP U value = 0.18 W/mK Phase shift 8 hours
1. Plaster boards 12.5 mm 2. EUROSTRAND OSB 4 TOP 15 mm 3. Mineral bre 035 220 mm 4. EGGER DHF 15 mm 5. Counter lathing 6. Cross joists 7. Roong tiles
6 1 5 4 7

2 3

CONVENTIONAL STRUCTURE WITH ESSENTIAL SARKING MEMBRANE U value = 0.35 W/mK Phase shift 7 hours
1. Cement lime plaster 2. HWL board 090 3. Mineral bre 045
1 7 5 6 4 8

4. Still air layer

Benets on a view

5. Sarking membrane 1.60 m

The use of EGGER DHF reduces thermal bridges eect of the rafters. Improvement of the summer heat protection and the noise control. Easy and quick installation supported by nailing lines at the surface.

6. Counter lathing 7. Cross joists 8. Roong tiles


2 3

07

Airtight roof construction

08

SPECIAL APPLICATIONS
1 3 2

NON-VENTILATED ROOF STRUCTURE WITH EUROSTRAND OSB 3 E0 AND/OR OSB 4 TOP (NOT TO SCALE)
1. 2. 3. 4. 5. 6. 7. 8. Metal roof (double skin partition) Structured separation layer 22 mm EUROSTRAND OSB 4 TOP Rafters Thermal insulation 200 mm Vapour barrier in accordance with meltwater calculation EUROSTRAND OSB 3 E0 or OSB 4 TOP 15 mm Plasterboard (optional)

METAL ROOF COVERING ON EUROSTRAND OSB Roof constructions with metal covering and a subconstruction made of OSB boards have been successfully used for several years. Tests carried out by WKI Braunschweig on the withdrawal strength of fasteners and by I.F.I. Aachen on durability properties under dynamic wind loads conrmed the suitability of EUROSTRAND OSB 3 E0 and OSB 4 TOP for this area of application. CONSTRUCTION RECOMMENDATIONS Only use EUROSTRAND OSB 3 E0 and OSB 4 TOP Board thickness 22 mm Recommended board size 2500 1250 mm Fasten the wall attachment/diaphragm attachment with ring nails (stainless steel) Moisture content of wooden construction (rafter) < 20 % Upper sided cover over the OSB with structured underlay, improves sound-proong by up to 6 dB Correct construction planning and execution with regard to thermal insulation and moisture protection Observe any re protection requirements (airborne ember and radiating heat) Observe the recommendations of the metal roof and membrane manufacturers!

6 7 8

ROOF CONSTRUCTIONS FOR HALLS WITH REQUIREMENTS TO FIRE RESISTANCE


This panel type is oered in particular for the design of roof and oor constructions with wide spans and requirements of 30 minutes re protection. As T&G2-panel with the size of 3000 1250 mm the intended use of this panel is the installation of disk supported frameworks (roof, oors, walls) with large spans up to 1.50 m in particular for shop buildings. The panel has an optimal size of 3.0 m length which reduces waste when cutting to size. Calculated according to EUROCODE EN 1995-1-2 the EUROSTRAND OSB with 30 mm thickness and a burn-up rate of 0.9 mm/minute provides a re protection function of 33 minutes.

Roof covering with EUROSTRAND OSB 4 TOP

09

The assembly hall of the Pilatus Aircraft Ltd. in Stans, Switzerland, with an area of 8800 m is built almost completely out of wood. The decision to use EUROSTRAND OSB 4 TOP and EGGER DHF as structural sheathing of wall and roof beneath faade and metal roof cover was taken because of the outstanding technical performance of these panels.

10

EGGER ENGINEERED WOOD PRODUCTS FOR USE IN CONSTRUCTION EUROSTRAND OSB


EUROSTRAND OSB is the right choice as a supporting and bracing element for walls and ceiling elements for all constructive applications with high load-bearing and dimensional stability requirements. Specially matched to the relevant field of application, the strength classes OSB/2 and OSB 3 E0 are available in accordance with EN 300 and OSB 4 TOP (with formaldehyde-free adhesive) in accordance with building regulations approval Z-9.1-566. The separate strand preparation for the surface and core layers, the specic strand geometry and a high degree of orientation of the strands ensures optimum technical properties and the highest possible degree of safety in construction planning. SERVICE CLASS According to EN 1995-1-1 (EC5) EUROSTRAND OSB 3 E0, OSB 4 TOP can be used in service class 1 (dry conditions) and 2 (humid conditions), and EUROSTRAND OSB/2 in service class 1. TONGUE AND GROOVE PROFILE The asymmetrical, conical tongue and groove prole of the board and cladding panel guarantees exact and rapid construction of oors, roofs and walls and the required stress transfer on braced (diaphragm action) board connections. In addition, it also improves the windproofness of the construction.

Note
In the context of the permission was regulated: Design values for fasteners like screws, staples, and nails. That enables to design the distribution of loads directly into the EUROSTRAND OSB 4 TOP panels. Structural glueing of the unsanded panels at edge and surface with approved PU glue from the Purbond HB product range (type HB 110, 440, 530)

Our plant in Wismar, Germany has been certified in accordance with ISO 9001 since 2001.

Most modern technology: With our 38.7 m ContiRoll we guarantee exibility and variety of panel sizes up to 11.5 2.8 m.

11

CALCULATION VALUES WITH RESPECT TO BUILDING PHYSICS EUROSTRAND OSB 3 E0 ACC. TO EN 300 AND EUROSTRAND OSB 4 TOP ACC. TO APPROVAL Z-9.1-566
Property
- value* (dry cup/wet cup) Thermal conductivity R Building materials class Reaction to fire (Euroclass) Burning rate 0, , t Linear expansion per 1 % material moisture change Density Thickness swelling 24 h Specic heat storage capacity c Formaldehyde emission

Test standard
ISO 12572 EN 13986 DIN 4102-1 EN 13986 EN 1995-1-2 EN 318 EN 323 EN 317 EN 12524 EN 120

Unit
W/mK mm/min %/% kg/m3 % J/kgK mg/100 g atro

EUROSTRAND OSB 3 E0
300/200 0.13 B2 ( 9 mm) D-s2, d0 0.9 0.03 600 15 1700 < 2.0 (E1 < 0,03 ppm)

EUROSTRAND OSB 4 TOP


200/200 0.13 B2 D-s2, d0 0.9 0.03 600 8-10 mm 12 / >10-40 mm 10 1700 < 2.0 (E1 < 0.03 ppm)

* Design values for water vapour diusion resistance factor . EUROSTRAND OSB 4 TOP corresponds to general building regulations approval Z-9.1-566. EUROSTRAND OSB 3 E0 in accordance with DIN V 20000-1.

CHARACTERISTIC VALUES FOR STRENGTH AND STIFFNESS EURODSTRAND OSB/2 AND OSB 3 E0 ACC. TO EN 300:2006 The characteristic design values for the structural assessment have been taken from EN 12369-1.
Strength values [N/mm] Thickness [mm] Bending
t nom 6 10 > 10 < 18 18 25 fm 0 ) 18.0 16.4 14.8 90 ) 9.0 8.2 7.4 0 9.9 9.4 9.0

Tension
ft 90 7.2 7.0 6.8

Compression
fc 0 15.9 15.4 14.8 90 12.9 12.7 12.4

Panel shear
fv 6.8 6.8 6.8

Planar shear
fr 1.0 1.0 1.0

Mean stiffness values [N/mm] Thickness [mm] Bending


t nom 6 10 > 10 < 18 18 25 1) 0 major axis 2) 90 minor axis Em 0 4930 4930 4930 90 1980 1980 1980 0 3800 3800 3800

Tension
Et 90 3000 3000 3000

Compression
Ec 0 3800 3800 3800 90 3000 3000 3000

Panel shear
Gv 1080 1080 1080

Planar shear
Gr 50 50 50

EUROSTRAND OSB 4 TOP The characteristic strength and stiness values for EUROSTRAND OSB 4 TOP in accordance with Z-9.1-566 are based on EN 1058 and EN 789.
Strength values [N/mm] Thickness [mm] Bending
t nom ... 10 > 10 < 18 18 25 > 25 30 > 30 40 fm 0 25 25 25 25 25 90 15 15 15 15 15 0 12 12 12 12 10

Tension
ft 90 10 10 10 10 10

Compression
fc 0 19 19 19 17 15 90 16 16 16 15 14

Panel shear
fv 9.0 9.0 9.0 8.0 6.0

Planar shear
fr 1.6 1.6 1.6 1.6 1.6

12

Mean stiffness values [N/mm] Thickness [mm] Bending


t nom 8 10 > 10 < 18 18 25 > 25 30 > 30 40 1) 0 major axis 2) 90 minor axis Em 0 ) 7000 7000 7000 7000 6000 90 ) 3000 3000 3000 3000 3000 0 4300 4300 4300 4300 4000

Tension
Et 90 3200 3200 3200 3200 3200

Compression
Ec 0 4300 4300 4300 4300 4000 90 3200 3200 3200 3200 3200

Panel shear
Gv 1500 1500 1500 1300 1200

Planar shear
Gr 160 160 160 140 140

EGGER DHF VAPOUR PERMEABLE WOOD FIBREBOARD


The EGGER DHF tongue and groove board provides all the advantages of vapour permeable external sarking as well as absorbing the horizontal force resulting from wind loads and thereby reinforcing the construction and making it more wind-proof. The conical tongue and groove prole ensures that water drains safely over the board joints. SERVICE CLASS According to ENV 1995-1-1 (EC5) EGGER DHF can be applied in service classes 1 (dry conditions) and 2 (humid conditions). When used as part-bearing bracing, constructive measures must be taken to ensure that the material moisture content of 15 % is not exceeded.

Water drainage

tongue and groove prole

CALCULATION VALUES WITH RESPECT TO BUILDINGS PHYSICS AND CHARACTERISTICS EGGER DHF IN ACCORDANCE WITH Z-9.1-454 AND EN 622-5 MDF.RWH The properties and characteristics of EGGER DHF correspond to the requirements of the general building regulations approval Z-9.1-454 of the DIBt (Deutsches Institut fr Bautechnik German institute for building technology).
Property
Density

Standard
EN 323

Unit
kg/m d

EGGER DHF
> 600 650 11 11 0.10 0.04 B2 normal flammability D-s2, d0 0.8 (E1 < 0.03 ppm) 1700 Sd 0.143 m 0.165 m

Diffusion resistance /Sd

ISO 12572

-/m

13 mm 15 mm

Thermal conductivity R Linear expansion due to humidity Building materials class (Euroclass) Reaction to fire (Euroclass) Formaldehyde emission Specific thermal capacity

Z-9.1-454 EN 318 DIN 4102-1 EN 13986 EN 120 EN 12524

W/mK %/% mg/100 g atro J/kgK

13

CHARATERISTIC VALUES FOR STRENGTH AND STIFFNESS EGGER DHF IN ACCORDANCE WITH Z-9.1-454
Strength values [N/mm] Thickness [mm] Bending
t nom 12 20 fm 19

Tension
ft 11.7

Compression
fc 9.6

Panel shear
fv 3.4

Planar shear
fr 1.1

Mean stiffness values [N/mm] Thickness [mm] Bending


t nom 12 20 Em 3000

Tension
Et 2100

Compression
Ec 2000

Panel shear
Gv 600

Planar shear
Gr 100

Thickness [mm]
t nom 12 20 12 20

Mean stiffness values [N/mm]


fh 18.0 d n > 3.0 mm 37.4 d n 3.0 mm

Calculated values for the modication factor kmod and the deformation coecient kdef, in accordance with DIN 1052:2004-08, type MBH.LA2 table F1 and F2
Load duration class
medium short instantaneous

k mod SC1
0.6 0.8 1.1

k def SC2
0.45 0.6 0.8 3.0 4.0

SC1

SC2

Static design according to Eurocode 5. The modication factor kmod and the deformation coecient kdef can be used for static measurement in accordance with Eurocode 5 (EN 1991-1-1:1994) in: SC1 = service class 1 = dry conditions and SC2 = service class 2 = humid conditions.

Vapour permeable and airtight constructions provide a long life span of the building.

14

PROCESSING RECOMMENDATIONS
The following instructions also apply to EUROSTRAND OSB and EGGER DHF. These are essential for correct use of the boards. STORAGE AND TRANSPORT Correct storage and protective measures during transport are essential for problem-free handling. The following simple principles should be taken into account: EUROSTRAND OSB and EGGER DHF should be stored at on several pieces of squared timber. The span width should be no greater than 80 cm and the pieces of squared timber should all be the same height. If several pallets are stacked on top of each other then the squared timber should be aligned by height. Steel bands should be undone immediately in the fabricators storeroom to prevent compressive strain on the pallet. Upright storage (practically vertical) is only suitable for a small number of boards on a dry oor. Tongue and groove boards In this case, only stand them on the groove side. In the case of transport by forklift truck the squared timber chosen must be suciently high so as to prevent damage. The boards must be suciently protected against weathering before being packed (closed lorry tarpaulin, polythene sheeting). Storage rooms should be uniformly air conditioned and free from large moisture and temperature uctuations. Before using the boards, a 48-hour period is recommended to allow the wood to acclimatise to local humidity.
max. 80 cm

Remove the steel bands on site

Package protected by lm cover

For acclimatisation on site: Boards propped up by battens

For acclimatisation on site: Boards secured in the corner of a room

15

MOISTURE PROTECTION EUROSTRAND OSB is characterised by low thickness swelling and a high degree of dimensional stability (see technical data: dimensional changes under inuence of moisture). When used as a supporting and bracing element, appropriate measures should be taken against weathering. According to EN/TS 12872 wood and wood-based materials with the following equilibrium moistures (see table) are t for use if installation is carried out correctly and no impermissible condensation can form. EQUILIBRIUM MOISTURE OF WOOD-BASED MATERIALS
Relative humidity (RH) at 20C
Service class 1, 30 % to 65 % Dry conditions Service class 2, 65 % to 85 % Humid conditions

Before installation the following should be inspected on site:


Board thickness Board type/permissible service class Compliance mark CE marking

Wood-based material approx. equilibrium moisture


4 % to 11 %

Application
Installed dry, no moisture during usage. Occasional increase in humidity during use; Installed externally under roof. No direct weathering.

11 % to 17 %

Dry screeds consisting of wood-based materials should only be laid in enclosed buildings once windows and doors have been tted. When installation is carried out in rooms without a cellar below, ensure sucient thermal insulation to prevent condensation forming on the underside of the board and possible warpage to the oor. In the case of concrete ceilings install a vapour barrier rst. PE lm with d > 0.2 mm which overlaps joints by 30 cm and can be installed right up to the upper edge of the oor is suitable. The board moisture should correspond to the local humidity where it will be installed. In the case of oor joists made of dry wood note that u < 15 %, since shrinkage of the subconstruction can result in long-term squeaking noises. When using wet construction materials, such as plaster, paint and wallpapering the resulting high humidity should be dispersed by adequate ventilation or other suitable means.

Wood and wood-based materials must not take in moisture from the surrounding construction components. If the oor cannot be immediately installed after the dry screed has been laid then the board surface must be covered with a PE lm or other suitable material to prevent it drying out or becoming more moist on one side, leading to deformation (cupping, buckling).

The use of EUROSTRAND OSB as a vapour control layer at the inside of vapour permeable constructions guarantees a sucient high safety against condensation risk.

16

DISPOSAL In its delivery condition, wood waste can be used as a material or for the production of energy. In this case it is classied according to Appendix III of the Waste Wood Ordinance to (EWC Codes) 030105, 150103 or 170201. According to the waste code, it will be decided by local waste laws what form the disposal will take. SAW DRILL MILL EUROSTRAND OSB can be sawn and milled like solid wood using conventional electrical hand tools. We recommend the use of hard-metal cutting tools. IF BOARDS WILL BE VISIBLE ONCE INSTALLED, NOTE THE FOLLOWING FOR A GOOD CUT: Sharp tool Workpiece must not vibrate Correct saw blade overhang Select a slightly lower feed rate compared to solid wood. Wear a respiratory mask if using hand tools without a dust extraction device. EUROSTRAND OSB can be drilled with all suitable electronic and manual machines suitable for solid wood. FASTENING EUROSTRAND OSB can be attached with all fasteners suitable for chipboard, such as screws, staples and nails. The length of the nail/screw should be 2.5 board thickness and at least 50 mm. With staples, a minimum wire gauge of 1.53 mm should be used. Corrosion resistant fasteners, e.g. made from galvanised or stainless steel, are to be used. Due to the high withdrawal strength, only at-head nails with gutter groove, screw nails or annularly threaded nails should be used (see also DIN 1052-2). The crosswise orientation of the strands in the EUROSTRAND OSB creates a secure base for the fastener, even in the outermost board edge. The thick core-layer structure ensures a high withdrawal strength around the edges.

Benets on a view
reduced edge distances for fasteners EUROSTRAND OSB 4 TOP edge distance > 4 dn Optimized timber cross sections

EUROSTRAND OSB 4 TOP > 4 dn OSB/2, OSB/3 > 7 dn

dn Nail diameter > 5 dn

7 dn

150

Fastening recommendation for non load-bearing EUROSTRAND OSB and EGGER DHF

Installation

150

7 dn

300

300

17

EUROSTRAND OSB is the right choice for all applications with high requirements according to load duration and dimensional stability.

18

CLADDING/STRUCTURAL SHEATHING WITH WOOD-BASED PANELS


INSTALLATION INSTRUCTIONS Detailed recommendations and basic rules for installation of wood-based materials for roofs, walls and ceilings can be found in EN/TS 12872. EDGE DISTANCES/EXPANSION JOINT FLOOR/ROOF, CEILING The installed wood-based panels must have an extra space of 15 mm to the surrounding construction components. This extra space enables tension free work to be carried out on the panels as well as ventilation in the case of ooring. Skirtings must be tted so that the oor has adequate ventilation. Glued plastic skirtings are not suitable. Trusses, etc. in the space should be suciently exposed. In areas with edge lengths > 10 m, expansion joints that are permanently elastic should be arranged.
Glueing of tongue and groove

WALL In the case of walls with edge lengths > 10 m expansion joints approx. 10 15 mm wide should also be added. FLOOR INSTALLATION The installation of the wood-based panels is carried out by joining them together and therefore requires hardly any cutting in the case of oating installation. Cross joints must not be formed. Panels must be oset by at least 40 cm. Tongue and groove panels can be tted in the adjacent wall area by simply putting them in at an angle in the groove. Free oating panel joints parallel to the supports are not permissible according to Eurocode 5 Timber construction. Overhanging panels must be cut back to the size of the decking. The frame of the subconstruction should match that of the available panel sizes in order to minimise cutting. On old oorboards, rst check the old screws, and tighten them if necessary. Cut free any boards that are rubbing against each other. Be aware of functional adjacent construction. BOARD THICKNESS In the case of oating installations with EUROSTRAND OSB use a board thickness of 18 mm. In the case of high concentrated and individual loads use a board thickness of at least 25 mm. SUBCONSTRUCTION FOR CERAMIC FLOOR COVERING The EUROSTRAND OSB boards must have a board thickness of at least 25 mm for oors and 18 mm in the case of walls and they must have high bending strength. The tongue and groove ooring boards must be glued under one another and pushed into place with force. They are screwed into the substructure (see also fastening section). Deection must not exceed e/600. When installing ceramic oors include permanently elastic expansion joints every 3 4 m.

Laying with the T&G Quick prole

19

EGGER DHF SPECIAL INSTRUCTIONS


EGGER DHF AS SUB-ROOFING ON THE RAFTERS EGGER DHF are vapour permeable underlay boards. They form a second water-repellent layer under the roof covering. They can be used on roofs with a minimum pitch of 16 with a max. 8 below the standard roof pitch (SRP) of the planned roof decking. They are installed with the tongue and groove joints from the eaves to the roof ridge, with tongues pointing towards the ridge. In the case of a shortfall of more than 8 the standard roof pitch must be a rain and water tight subroof. With a board thickness 15 mm EGGER DHF, as rafters, is walkable up to a rafter grid of 1 m acc. to NORM B4119 (before ONR 22219-2 dry board). UNDERLAY CLASSIFICATION As interlocked underlay of the type UDP-A (rigid underlay, type A, with circumferential tongue and groove prole), the boards are assigned to Class 3 according to the ZVDH guidelines. EGGER DHF can be installed without an additional nail sealing strip under the counter-batten and without taping the tongue and groove joint, even in case of elevated requirements and with a roof pitch up to 8 less than the regulation pitch. Compliance with the minimum roof pitch of 16 is mandatory. Openings (for chimneys etc.) and joints (covings, groins, dormers etc.) must be taped using suitable adhesive tape. Increased requirements in addition to shortfall of standard roof pitch: Use of attic, especially as living space Special construction features, e.g. dormer windows, ridges, complicated roof shapes Climatic factors, e.g. mountains or coasts Local requirements, e.g. from building control ADDITIONAL GLUING A taped underlay must be implemented when the roof pitch is less than the regulation pitch of 16 by a maximum of 8. All board joints are taped using suitable adhesive tape. The minimum roof pitch is 10. TRANSIENT WEATHERING After installing EGGER DHF the roof covering/facade should be tted immediately. Between March and November the boards can be exposed to natural weathering for 2 months as a temporary roof. In the winter months, structural measures must be employed to ensure that the external covering layer of EGGER DHF cannot freeze, since this would seriously impair the diusion ability of the external panelling cladding and potentially lead to moisture damage. In the winter months it should only be exposed to natural weathering for a maximum of 2 weeks. If EGGER DHF is used for load-bearing purposes then the moisture protection regulations of the approval Z-9.1-454 apply and DIN 68800-2, i.e. the tted boards have to be protected from natural weathering. UNINSULATED COCK-LOFT The roof area of an uninsulated cock-loft and an unconverted attic must also be ventilated even by using a vapour permeable sub-roong material. The recommended ventilation cross-section, derived from the regulations for the ventilation of at roofs is 200 cm per running meter at the ridge and the eaves.
EGGER DHF used as rigid underlay

Note
If the pitch of the roof is less then 8 further measures should be taken to ensure rain and water tightness of the roof covering (i.e. taping the EGGER DHF panel joints).

Note
During the winter months, icing of the outer layer of the EGGER DHF board must be excluded by means of suitable construction measures, since this would severely impair the diusion characteristics of exterior sheathing, which may result in moisture damage.

Ventilation of uninsulated cock-loft

20

DIMENSIONING
Wooden structures are designed according to the appropriate National and European standards. In the medium-term, Eurocode 5 has been introduced as an EU-wide regulation for the design of wooden constructions. Characteristic values for the structural design of EUROSTRAND OSB in accordance with Eurocode 5 can be taken from DIN EN 12369-1 or from the building authorities. The following assessment tables were created using the regulations for EUROSTRAND OSB 4 TOP in accordance with approval Z-9.1-566 as well as the rules for the assessment of wooden constructions in accordance with Eurocode 5.

Note
The tables contain recommended values and are not intended as a substitute for individual verication by a structural engineer.

LOADING TABLES FOR EUROSTRAND OSB PRE-DIMENSIONING OF WALL PANELS FOR HORIZONTAL FORCE The calculation is based on the regulations in DIN 1052-1:1988, section: 11.4.2 on the testing of tensile force on the board. To prevent the planking from buckling, the timber stud distances should be limited to ar = 83.3 cm. WALL PANELS IN THE HEIGHT H UNDER HORIZONTAL STRESS Horizontal force allowable Fv(KN/ar)
F v (KN/a r ) permissible Wall panels in the height h under horizontal stress h = 2.50 m 10 mm
62.5 1- a r 2- a r 83.5 1- a r 3- a r 100.0 1- a r 2- a r 125.0 1- a r 2- a r 1.89 3.18 3.25 5.87 4.34 6.49 6.36 8.80

Timber stud distance a r (cm) *

h = 2.65 m 15 mm
2.71 4.73 4.71 8.80 6.38 9.73 9.45 13.20

h = 2.80 m 15 mm
2.57 4.56 4.48 8.67 6.17 9.55 9.11 13.01

12 mm
2.17 3.78 3.77 7.04 5.10 7.79 7.56 10.56

10 mm
1.79 3.08 3.09 5.91 4.24 6.45 6.24 8.86

12 mm
2.05 3.65 3.58 6.94 4.96 7.64 7.26 10.40

10 mm
1.71 2.95 2.95 5.65 4.05 6.16 5.90 8.47

12 mm
1.95 3.48 3.41 6.78 4.71 7.39 6.96 10.16

15 mm
2.44 4.35 4.26 8.47 5.89 9.24 8.70 12.70

* Panel with one, two or three timber stud distances ar. In the case of double-sided planking, double the permissible Fv(KN/ar) values.

ASSUMPTIONS The longitudinal edge of the board runs parallel to the wall studs. There are no horizontal joints in the area. The nailing is carried out using staples with 1.8 mm wire gauges with a length of 55 mm and a clearance of 50 mm; N1 = 280 N permissible.

21

PRE-DIMENSIONING OF HORIZONTAL PLANKING AS DOUBLE-SPAN BEAM FOR VERTICAL LOADS The following table species the required board thickness with the application of vertical loads only (e.g. shelving, sheathing wood beam layer) without plate eect, dependent on the ridge retention ar.

PRE-DIMENSIONING OF 1 SINGLE GIRDER WITH EUROSTRAND OSB 3 E0

Needed board thickness d (mm) qk [kN/m] / Qk [kN] Categorie of use A 2.0 / 1.0 gk ar (cm)
41.7 50.0 60.0 62.5 70.0 80.0 83.3 90.0 100.0 120.0

Categorie of use B2 3.0 / 3.0 gk 1.5


15 15 18 22 22 25 25 2*22 2*22 2*25

0.5
12 15 18 18 22 22 25 25 2*22 2*25

1.0
12 15 18 18 22 25 25 2*22 2*22 2*25

0.5
15 15 18 22 22 25 25 2*22

1.0
15 18 22 22 22 25 2*22 2*22

1.5
15 18 22 22 25 25 2*22 2*22

Boundary condition: panel width, b = 1.25 m, point load uniform distributed gk = imposed load uniformally distributed Qk = concentrated point load qk = uniformally distributed self weight load

PRE-DIMENSIONING OF 1 SINGLE GIRDER WITH EUROSTRAND OSB 4 TOP

Needed board thickness d (mm) qk [kN/m] / Qk [kN] Categorie of use A 2.0 / 1.0 gk ar (cm)
50.0 60.0 62.5 70.0 80.0 83.3 90.0 100.0 120.0

Categorie of use B2 3.0 / 3.0 gk 1.5


15 18 18 22 22 25 25 30 40

0.5
12 15 18 18 22 22 22 25 30

1.0
15 18 18 18 22 22 25 30 40

0.5
15 18 18 22 22 22 25 30 40

1.0
15 18 18 22 25 25 25 30 40

1.5
15 18 18 22 25 25 30 30 40

Boundary condition: panel width, b = 1.25 m, point load uniform distributed gk = imposed load uniformally distributed Qk = concentrated point load qk = uniformally distributed self weight load

22

PRE-DIMENSIONING OF HORIZONTAL PLANKING AS DOUBLE-SPAN BEAM FOR VERTICAL LOADS The following table species the required board thickness with the application of vertical loads only (e.g. shelving) without plate eect, dependent on the ridge retention ar.

PRE-DIMENSIONING OF 2 SINGLE GIRDERS, LOADED ON BOTH SIDES WITH EUROSTRAND OSB 3 E0

Needed board thickness d (mm) qk [kN/m] / Qk [kN] Categorie of use A 2.0 / 1.0 gk ar (cm)
50.0 60.0 62.5 70.0 80.0 83.3 90.0 100.0 120.0

Categorie of use B2 3.0 / 3.0 gk 1.5


12 15 15 18 22 25 25 25 2*22

0.5
12 15 15 18 22 22 22 25 2*22

1.0
12 15 15 18 22 25 25 25 2*22

0.5
15 15 18 18 22 25 25 2*22 2*25

1.0
15 18 18 18 22 25 25 2*22 2*25

1.5
15 18 18 22 22 25 25 2*22 2*25

Boundary condition: panel width, b = 1.25 m, point load uniform distributed gk = imposed load uniformally distributed Qk = concentrated point load qk = uniformally distributed self weight load

PRE-DIMENSIONING OF 2 SINGLE GIRDERS, LOADED ON BOTH SIDES WITH EUROSTRAND OSB 4 TOP

Needed board thickness d (mm) qk [kN/m] / Qk [kN] Categorie of use A 2.0 / 1.0 gk ar (cm)
50.0 60.0 62.5 70.0 80.0 83.3 90.0 100.0 120.0

Categorie of use B2 3.0 / 3.0 gk 1.5


12 15 15 18 18 22 22 25 30

0.5
12 12 15 15 18 18 18 22 25

1.0
12 15 15 15 18 18 22 22 30

0.5
12 15 15 18 22 22 22 25 30

1.0
15 15 18 18 22 22 25 25 30

1.5
15 15 18 22 22 22 25 30 30

Boundary condition: panel width, b = 1.25 m, point load uniform distributed gk = imposed load uniformally distributed Qk = concentrated point load qk = uniformally distributed self weight load

23

EGGER DHF as structural sheathing, up to 3.0 m storey high sheathing in classied wall structure REI 30 acc. to EN 13501-2

24

EGGER DHF PRE-DIMENSIONING OF WALL PANELS The following design tables are based on one-sided external panelling of the supporting structure using EGGER DHF. The calculated values for humid conditions (service class 2) are used. The calculations were carried out in accordance with the regulations set out in DIN 1052-1:1988-04, 11.4.2, on the testing of tensile force on the board. ASSUMPTIONS The longitudinal edge of the board runs parallel to the wall studs. There are no horizontal joints in the area. The nailing is carried out using clips with 1.53 mm wire gauges with a length of 55 mm and a clearance of 50 mm; N1 = 250 N permissible. Sheathing thickness d = 13 mm / 15 mm (0.51 / 0.59)

Note
The following design tables are recommendations. They cannot replace the static calculation by a permitted civil engineer.

F v (KN/a r ) permissible Wall panels in the height h under horizontal stress Timber stud distances a r (cm)
62.5* 83.5** 2- a r 3- a r

h = 2.50 m 13 mm
1.46 2.44

h = 2.65 m 13 mm
1.41 2.43

h = 2.80 m 13 mm
1.36 1.42

15 mm
1.69 2.81

15 mm
1.63 2.81

15 mm
1.57 2.79

* Panel with two timber stud distances ar. ** Panel with three timber stud distances ar.

IMPORTANT DOCUMENTS AND STANDARDS Additional processing instructions and application examples can be found at/in: www.egger.com Eurocode 5 EN 1991-1-1 Timber construction in conjunction with the nationally applicable usage document (national timber construction standard) EN/TS 12872 Wood-based panels. Guidance on the use of load-bearing boards in oors, walls and roofs

25

Picture: Production of export cases made of EUROSTRAND OSB according to ISPM 15 Standard

Picture: Shelf and storage system Schottel company, Wismar, EUROSTRAND OSB 4 TOP

Picture: Airport Munich, Terminal 2, EUROSTRAND OSB 3 E0, 20 mm, as concrete shuttering

Picture: I-beam production with EUROSTRAND OSB 3 E0

26

STOCK PROGRAM EUROSTRAND OSB AND EGGER DHF / PLANT WISMAR


Product/ length width (mm)

Board thickness d (mm) 6 8 9 10 11 12 13 15 18 20 22 25 30 40

EUROSTRAND OSB 4 TOP Z-9.1-566 Straight edge unsanded 5000 2500 5000 1250 2960 2500 3000 1250 2800 1250 2650 1250 2500 1250 T&G 4 unsanded 2500 675 2500 1250 T&G 4 sanded 2500 675 2500 1250 T&G 2 unsanded 6250 675 EUROSTRAND OSB 3 E0 EN 300 Straight edge unsanded 5000 2500 5000 1250 3000 1250 2800 1250 2650 1250 2500 1250 2070 2770 T&G 4 unsanded 2500 675 2500 1250 T&G 4 sanded 2500 675 2500 1250 T&G 2 unsanded 2440 1205 EUROSTRAND OSB/2 EN 300 Straight edge unsanded 2440 1220 EGGER DHF underlay boards acc. to Z-9.1-454 / EN 622-5 MDF.RWH T&G 4 unsanded 2500 1250 2500 675 T&G 2 unsanded 2800 1250 3000 1250 * on request (by load) ** Delivery by request, production as individual customer order 250 m (8,829 cubic feet)

** * * * * * * **

**

**

**

* ** *

We reserve the right to make changes to the stock program.


27

www.egger.com
www.egger.com

TECHNICAL HOTLINE
t +49 3841 301 - 21260 f +49 3841 301 - 20222 construction@egger.com

EGGER Holzwerkstoe Wismar GmbH & Co. KG Am Haeld 1 23970 Wismar Germany t +49 3841 301-21260 f +49 3841 301-61260 holzbau@egger.de

EGGER (UK) Limited Anick Grange Road Hexham, Northumberland NE46 4JS United Kingdom t +44 1434 602191 f +44 1434 605103 building.uk@egger.com

EN_879274_01/13 Subject to technical alterations. Without guarantee for printing errors, standard errors and mistakes.

EGGER Building Products GmbH Weiberndorf 20 6380 St. Johann in Tirol Austria t +43 50 600-0 f +43 50 600-10111 info-ebp@egger.com