We invest in technology to produce the future


Isopan performs its business in the eld of production and sale of insulating panels with metal supports for wall and roof coverings having a high isothermal coefcient. The product lines also include attachment groups, sheet metal for nishing and the collection of rainwater, translucid undulated elements, windows for walls, xed or motorised skylights. Isopan panels are manufactured with a continuous process, guaranteeing uniform and constant quality, controlled by state of the art diagnostics plants. The polyurethane (PUR) and polyisocyanurate (PIR) foams are both selfextinguishing and are injected under high pressure, thanks to an exclusive know-how, ensuring excellent thermal insulation, optimum mechanical resistance and a totally monolithic panel. Research and development in recent years has permitted the realisation of sound absorbent panels, panels for refrigerated cells and architectural panels with high resistance to re. Additionally, in its modern Service Centre, Isopan realizes the entire range of sheet metal, with collaborating and undulated sheet metal panels that complete the Isopan System.

Isopan: a service that delivers content


Being able to listen and wanting to understand are the basic conditions for transforming good intentions into effective and incisive service to the customer. Applying this concept is what gives practical value to Isopans Customer Service. Our team of professionals is kept informed by a constant stream of data and information, and works closely with customers to interpret their specic requirements. We invest heavily in the human resources dedicated to Customer Service, and this complements our solid commitment to research and development devoted to the product. The technical properties of our rolled metal proles are regularly tested on the line and in the laboratory, for continual improvement in qualitative content. We pay par ticular attention to the chemistr y of polyurethanes, in order to develop and expand the elds of application of the resins. Our state-of-the-art logistical structure ensures that orders are despatched on time and as agreed. Strict integration between the manufacturing and distribution operations ensures ultra-fast delivery times in Europe countries and abroad.

ISOPAN FROSINONE

ISOPAN IBRICA

ISOPAN TREVENZUOLO

ISOPAN EST

Isopan: a single large market


Isopan has a presence in the most important markets in the world through a consolidated network of direct and indirect agents. The Export Division offers specic solutions for the different foreign markets we supply, with its own flexible manufacturing capability suppor ted by its own European production facilities, a rapid transport system and an efficient technical assistance service.

Choosing quality as the corporate philosophy


Working for Quality means never disappointing our customers, and Isopan knows that the rst step on this road is the technical performance of the product. The commitment to Quality Certication is one among many which Isopan has made to maintain the high qualitative level of its output. This is the reason why we will only accept suppliers with the capacity to deliver materials of proven reliability, always guaranteed and certied, in full compliance with international Standards. Our panels consist essentially of an insulating core of polyurethane, with a backing of proled metal, and must be capable of providing a double barrier: one against corrosion, the other against heat dispersal. For this reason we use selected components such as: rolled steel sheets protected with a zinc coating and a lm of paint, to put up a powerful barrier to deterioration caused by atmospheric agents, and expanded polyurethanes and polyisocyanurates, the most effective known insulators for combating heat transmission. The selected backing sheets are rigorously checked for uniformity of surface, high adherence of the zinc to the steel, and perfect adhesion of the paints to the backing sheet. The paints themselves are chosen for their suitability in view of the aggressiveness of the atmosphere to which they will be exposed. The rigid, closed-cell, high-density polyurethane component is well-known for its high and constant insulating value, its outstanding physical characteristics (veried by stringent tests of compression, bending and dimensional stability), and its good performance in self-extinguishing. The panel functions as a monolithic structure: this is ensured by a special primer applied to the metal backing which produces excellent adhesion of the insulation.

The group
Dependability and safety, essential and aesthetically pleasing lines: steel, in a word. From supply by our commercial organisation of the widest range of iron and steel products, to the most complete processing, the Manni Group is close to its Customers in every phase of the productive process. Innovating services to create value for our Customers: this is the mission that the Manni Group faces with its various companies. The entire system rotates around the Customer, utilising capabilities and competence to improve performance, even in favour of the nal user. Growing together and acquiring knowledge: thats how the Customer participates the continuous improvement of our proposal, which is open to updating integrated with his organisation.

The gures
Stated synthetically, the Manni Group means 9 operational companies, 20 production, service and distribution centres, over 600,000 tonnes of steel processed and distributed, over 14 million square metres of metal insulating panels produced and distributed in Italy and abroad, over 900 employees and a turnover of over 600 million euros.

...Your Domus
ISODOMUS

Panel used: Isoparete Pliss and Isoclass

Wall panels

ISOBOX 1000
A panel designed for wall use. Characterized by the symmetry of its section and by the micro-ribbed surfaces, designed to satisfy the growing aesthetic demands in the eld of designing external walls and internal partitions. This product represents a solution that goes hand in hand with economic, practical and functional characteristics.

1000

thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0.10 N/mm2 - value of compression at 10% of deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK.

WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established - Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces.
* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: WALL USE PVC screw-washer (*) - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 2030 mm Two for extreme support panels One for intermediate support panels

FIRE RESISTANCE Panels ISOBOX 1000 eld-tested have obtained the following results: EW 60 for 80 mm thick panels (in accordance with EN 13501-2) FIRE REACTION Panels ISOBOX 1000 eld-tested have obtained the following results: C-S3-D0 for 50 mm thick panels (in accordance with EN 13501-1)

Quantity:

(*) In the case of strong depression a 50 mm diam. washer should be interposed. For panels with aluminium supports request special instructions.

10

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0,5 mm EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 245 220 200 190 180 170 285 255 235 220 205 195 345 310 285 265 250 235 25 30 PANEL THICKNESS mm 40 50 405 360 335 310 295 280 60 455 410 380 355 335 315 80 545 490 450 420 395 375 100 635 570 525 490 460 435 120 715 640 590 550 520 490 25 280 255 230 220 205 200 30 325 295 270 255 240 230 MAX. SPAN cm 395 355 330 310 290 275 PANEL THICKNESS mm 40 50 460 420 385 360 340 325 60 525 475 435 410 385 370 80 620 565 520 485 460 435 100 725 655 605 565 535 510 120 805 735 680 635 600 575 MAX. SPAN cm

SHEET STEEL THICKNESS 0,4 mm EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 120 140 daN/m2 58 78 98 117 137 225 200 185 170 160 25 PANEL THICKNESS mm 30 255 230 210 195 185 40 315 280 260 240 225 50 365 330 300 280 265 25 260 235 215 200 190 MAX. SPAN cm PANEL THICKNESS mm 30 295 265 245 230 215 40 360 325 300 280 265 50 420 380 350 330 310 MAX. SPAN cm

INSTALLATION EXAMPLE

WEIGHTS OF PANELS
STEEL WEIGHT THICKNESS
0.4 0.5 kg/m2 kg/m2

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


NOMINAL THICKNESS OF PANEL mm
25 7.5 9.1 30 7.7 9.3 40 8.1 9.7 50 8.5 60 8.9 80 9.7 100 120 Length Effective width Thickness Deviation from perpendicularity 120 0.18 0.15 Misalignment of internal metal facing Sheets closing 10.4 11.2

DEVIATIONS mm
L3m L>3m 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm

10.1 10.5 11.3 12.1 12.9

THERMAL INSULATION
K
25 W/m2 K kcal/m2 h C 0.75 0.67 30 0.64 0.57

NOMINAL THICKNESS OF PANEL mm


35 0.56 0.49 40 0.50 0.44 50 0.40 0.35 60 0.34 0.30 80 0.26 0.23 100 0.21 0.18

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 micro-ribbed in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint micro-ribbed in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint Coeff. of thermal transmission: K = type of xing W/m2 K kcal/m2 h C ; screw type and shank ; qty prevarnished on the visible side series colour prevarnished on the visible side series colour

made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10%,

11

ISORIGHE 1000
A panel designed for wall use. Characterized by the symmetry of its section and by the micro-ribbed surfaces, designed to satisfy the growing aesthetic demands in the eld of designing external walls and internal partitions. This product represents a solution that goes hand in hand with economic, practical and functional characteristics.

1000

thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0.10 N/mm2 - value of compression at 10% of deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK.

WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established - Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces.
* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: WALL USE PVC screw-washer (*) - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 2030 mm Two for extreme support panels One for intermediate support panels

Quantity:

(*) In the case of strong depression a 50 mm diam. washer should be interposed. For panels with aluminium supports request special instructions.

12

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 245 220 200 190 180 170 285 255 235 220 205 195 310 280 255 240 225 215 25 30 35 PANEL THICKNESS mm 40 345 310 285 265 250 235 50 405 360 335 310 295 280 60 455 410 380 355 335 315 80 545 490 450 420 395 375 100 635 570 525 490 460 435 120 715 640 590 550 520 490 25 280 255 230 220 205 200 30 325 295 270 255 240 230 MAX. SPAN cm 360 325 300 280 265 250 PANEL THICKNESS mm 35 40 395 355 330 310 290 275 50 460 420 385 360 340 325 60 525 475 435 410 385 370 80 620 565 520 485 460 435 100 725 655 605 565 535 510 120 805 735 680 635 600 575 MAX. SPAN cm

ALUMINIUM STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 180 165 150 140 135 125 210 190 175 165 155 145 230 210 190 180 170 160 25 30 35 PANEL THICKNESS mm 40 260 235 215 200 190 180 50 300 270 250 235 220 210 60 340 310 285 265 250 240 80 405 365 335 310 295 280 100 470 430 390 365 345 325 120 525 475 435 405 385 365 25 210 190 175 165 155 145 30 245 220 205 190 180 170 MAX. SPAN cm 265 240 220 210 195 190 PANEL THICKNESS mm 35 40 295 265 245 230 220 210 50 345 310 290 270 255 245 60 390 355 325 305 290 275 80 460 415 385 360 340 325 100 535 485 445 420 395 375 120 600 545 500 470 445 425 MAX. SPAN cm

F
WEIGHT
25 kg/m2 9.20 30 9.40 35 9.60 40 9.80 50 10.20

WEIGHTS OF PANELS
NOMINAL THICKNESS OF PANEL mm
60 10.60 80 11.50 100 12.30 120 13.10

F DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width L3m L>3m 2 mm D 100 mm 2 mm D > 100 mm 2 % Deviation from perpendicularity Misalignment of internal metal facing Sheets closing 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm

Thickness

THERMAL INSULATION
K
25 W/m K
2

Where L is the length and D is the thickness of the panels.

NOMINAL THICKNESS OF PANEL mm


30 0.64 0.57 35 0.56 0.49 40 0.50 0.44 50 0.40 0.35 60 0.34 0.30 80 0.26 0.23 100 0.21 0.18 120 0.18 0.15 0.75 0.67

kcal/m2 h C

FIRE REACTION Panels ISORIGHE 1000 eld-tested have obtained the following results: C-S3-D0 for 50 mm thick panels (according to EN 13501-1)

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 micro-ribbed in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint micro-ribbed in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint Coeff. of thermal transmission: K = type of xing W/m2 K kcal/m2 h C ; screw type and shank ; qty prevarnished on the visible side series colour prevarnished on the visible side series colour

made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10%,

13

ISOPIANO 1000
A panel designed for wall use. Characterized by the symmetry of the sections and by the planarity of the surfaces. Designed to satisfy aesthetic and architectural needs in the realization of inner partition walls.

1000

thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0.10 N/mm2 - value of compression at 10% of deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK.

WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established - Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces.
* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: WALL USE PVC screw-washer (*) - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 2030 mm Two for extreme support panels One for intermediate support panels

Quantity:

(*) In the case of strong depression a 50 mm diam. washer should be interposed. For panels with aluminium supports request special instructions.

14

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 245 220 200 190 180 170 285 255 235 220 205 195 310 280 255 240 225 215 25 30 35 PANEL THICKNESS mm 40 345 310 285 265 250 235 50 405 360 335 310 295 280 60 455 410 380 355 335 315 80 545 490 450 420 395 375 100 635 570 525 490 460 435 120 715 640 590 550 520 490 25 280 255 230 220 205 200 30 325 295 270 255 240 230 MAX. SPAN cm 360 325 300 280 265 250 PANEL THICKNESS mm 35 40 395 355 330 310 290 275 50 460 420 385 360 340 325 60 525 475 435 410 385 370 80 620 565 520 485 460 435 100 725 655 605 565 535 510 120 805 735 680 635 600 575 MAX. SPAN cm

ALUMINIUM STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 180 165 150 140 135 125 210 190 175 165 155 145 230 210 190 180 170 160 25 30 35 PANEL THICKNESS mm 40 260 235 215 200 190 180 50 300 270 250 235 220 210 60 340 310 285 265 250 240 80 405 365 335 310 295 280 100 470 430 390 365 345 325 120 525 475 435 405 385 365 25 210 190 175 165 155 145 30 245 220 205 190 180 170 MAX. SPAN cm 265 240 220 210 195 190 PANEL THICKNESS mm 35 40 295 265 245 230 220 210 50 345 310 290 270 255 245 60 390 355 325 305 290 275 80 460 415 385 360 340 325 100 535 485 445 420 395 375 120 600 545 500 470 445 425 MAX. SPAN cm

F
WEIGHT
25 kg/m2 9.20 30 9.40 35 9.60 40 9.80 50 10.20

WEIGHTS OF PANELS
NOMINAL THICKNESS OF PANEL mm
60 10.60 80 11.50 100 12.30 120 13.10

F DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width L3m L>3m 2 mm D 100 mm 2 mm D > 100 mm 2 % Deviation from perpendicularity Misalignment of internal metal facing Sheets closing 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm

Thickness

THERMAL INSULATION
K
25 W/m K
2

Where L is the length and D is the thickness of the panels.

NOMINAL THICKNESS OF PANEL mm


30 0.64 0.57 35 0.56 0.49 40 0.50 0.44 50 0.40 0.35 60 0.34 0.30 80 0.26 0.23 100 0.21 0.18 120 0.18 0.15 0.75 0.67

kcal/m2 h C

FIRE REACTION Panels ISOPIANO1000 eld-tested have obtained the following results: C-S3-D0 for 50 mm thick panels (according to EN 13501-1)

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 at in galvanized steel/embossed aluminium thickness mm with 5 microns of primer and 20 microns of paint at in galvanized steel/embossed aluminium thickness mm with 5 microns of primer and 20 microns of paint Coeff. of thermal transmission: K = type of xing W/m2 K kcal/m2 h C ; screw type and shank ; qty prevarnished on the visible side series colour prevarnished on the visible side series colour (1) (1)

made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10%,

(1) Alternatively, a PVC lamina nish, thickness 100 microns.

15

NUOVO ISOPARETE 1000

A panel designed for wall use. Characterized by its interlock and xing system, it produces systems that last throughout the years and that are at the same time aesthetically valid: the xing, hidden by its interlocks, provides it with a very modular profile. This joint ensures a high level of air thightness.

1000 thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0,020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0,10 N/mm2 - value of compression at 10% of deformation: 0,11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK.

WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established - Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces.
* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: WALL USE IN NORMAL CONDITIONS screw - self-tapping diam. 6,0 mm for surface support 3 mm - self-threading diam. 6,3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel - 510 mm One per panel for all supports WALL USE IN STRONG DEPRESSION screw-plate 20x60 mm - self-tapping diam. 6,0 mm for surface support 3 mm - self-threading diam. 6,3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel - 510 mm One per panel for all supports

Quantity:

For panels with aluminium supports request special instructions.

16

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 310 280 255 240 225 215 345 310 285 265 250 235 35 40 PANEL THICKNESS mm 50 405 360 335 310 295 280 60 455 410 380 355 335 315 80 545 490 450 420 395 375 100 635 570 525 490 460 435 35 360 325 300 280 265 250 40 395 355 330 310 290 275 MAX. SPAN cm PANEL THICKNESS mm 50 460 420 385 360 340 325 60 525 475 435 410 385 370 80 620 565 520 485 460 435 100 725 655 605 565 535 510 MAX. SPAN cm

ALUMINIUM STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m 60 80 100 120 140 160
2

PANEL THICKNESS mm 35 40 260 235 215 200 190 180 50 300 270 250 235 220 210 60 340 310 285 265 250 240 80 405 365 335 310 295 280 100 470 430 390 365 345 325 35 265 240 220 210 195 190 40
2

PANEL THICKNESS mm 50 345 310 290 270 255 245 60 390 355 325 305 290 275 80 460 415 385 360 340 325 100 535 485 445 420 395 375 MAX. SPAN cm 295 265 245 230 220 210

daN/m 58 78 98 117 137 156

MAX. SPAN cm 230 210 190 180 170 160

INSTALLATION EXAMPLE

F WEIGHTS OF PANELS
WEIGHT
kg/m2

NOMINAL THICKNESS OF PANEL mm


35 10.10 40 10.30 50 10.70 60 11.10 80 11.90 100 12.70

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing Sheets closing L3m L>3m 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm

THERMAL INSULATION
K
35 W/m2 K kcal/m2 h C 0.56 0.49

NOMINAL THICKNESS OF PANEL mm


40 0.50 0.44 50 0.40 0.35 60 0.34 0.30 80 0.26 0.23 100 0.21 0.18

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 micro-ribbed in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint micro-ribbed in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint Coeff. of thermal transmission: K = type of xing W/m2 K kcal/m2 h C ; screw type and shank ; qty prevarnished on the visible side series colour prevarnished on the visible side series colour

made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10%,

17

NUOVO ISOPARETE PIANO 1000


A panel designed for wall use. Characterized by its interlock and xing system, it produces systems that last throughout the years and that are at the same time aesthetically valid. A product with a high level of aesthetic and architectural prestige. It combines quality and planarity of the surfaces with that of the xing hidden within the interlock. This joint ensures a high level of tightness.

1000 thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0,020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0,10 N/mm2 - value of compression at 10% of deformation: 0,11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK.

WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established - Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces.
* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: WALL USE IN NORMAL CONDITIONS screw - self-tapping diam. 6,0 mm for surface support 3 mm - self-threading diam. 6,3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel - 510 mm One per panel for all supports WALL USE IN STRONG DEPRESSION screw-plate 20x60 mm - self-tapping diam. 6,0 mm for surface support 3 mm - self-threading diam. 6,3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel - 510 mm One per panel for all supports

Quantity:

For panels with aluminium supports request special instructions.

18

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 310 280 255 240 225 215 345 310 285 265 250 235 35 40 PANEL THICKNESS mm 50 405 360 335 310 295 280 60 455 410 380 355 335 315 80 545 490 450 420 395 375 100 635 570 525 490 460 435 35 360 325 300 280 265 250 40 395 355 330 310 290 275 MAX. SPAN cm PANEL THICKNESS mm 50 460 420 385 360 340 325 60 525 475 435 410 385 370 80 620 565 520 485 460 435 100 725 655 605 565 535 510 MAX. SPAN cm

ALUMINIUM STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 230 210 190 180 170 160 260 235 215 200 190 180 35 40 PANEL THICKNESS mm 50 300 270 250 235 220 210 60 340 310 285 265 250 240 80 405 365 335 310 295 280 100 470 430 390 365 345 325 35 265 240 220 210 195 190 40 295 265 245 230 220 210 MAX. SPAN cm PANEL THICKNESS mm 50 345 310 290 270 255 245 60 390 355 325 305 290 275 80 460 415 385 360 340 325 100 535 485 445 420 395 375 MAX. SPAN cm

WEIGHTS OF PANELS
WEIGHT NOMINAL THICKNESS OF PANEL mm
35 kg/m
2

40 10.30

50 10.70

60 11.10

80 11.90

100 12.70

10.10

THERMAL INSULATION
K
W/m2 K kcal/m2 h C

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing Sheets closing L3m L>3m 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm 50 0.40 0.35 60 0.34 0.30 80 0.26 0.23 100 0.21 0.18

NOMINAL THICKNESS OF PANEL mm


35 0.56 0.49 40 0.50 0.44

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 at in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint at in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint Coeff. of thermal transmission: K = type of xing W/m2 K kcal/m2 h C ; screw type and shank ; qty prevarnished on the visible side series colour prevarnished on the visible side series colour

made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10%

19

ISOPARETE 1000
A panel designed for wall use. It features a patented system for xing panels and slotting them together, and offers a finished product with good looks and durability. The xing system, which is concealed in the joints, makes the design of the prole modular.

thickness 1000

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Rolled steel sheets galvanised by the Sendzimir process (UNI EN 10326-UNI EN 10327) - Rolled steel sheets galvanised and prepainted by the Coil Coating process - Rolled sheets in aluminium alloy, with natural nish, embossed and prepainted (EN 485) - Prepainting carried out by continuous process, with thickness on the visible side of 5 microns of primer and 20 microns of paint, in the following series: PS-PX-PVDF (special products can be supplied on request, with extremely high anti-corrosion properties). - Rolled copper sheets (DIN 1787/17670/1791). INSULATING CORE Rigid foam with high insulating power with a base of polyurethane (PUR) or polyisocyanurate (PIR) resins, both self-extinguishing*, meeting the following qualitative standards: - reference thermal conductivity at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - adhesion value to supports: 0.10 N/mm2 - compression value at 10% deformation: 0.11 N/mm2. THERMAL INSULATION The heat transmission coefcients K stated in the sheet should be treated as useful design values, at 10C; the calculation takes account of the two laminar resistances, external and internal, and of the calculated useful thermal conductivity at 10C (obtained by applying to m the loading m = 10%): = 0.022 W/mK.

LOADING - Deformation: a maximum curvature of 1/200 L is permissible - Deection: it is assumed that the deecting force is completely absorbed by the supporting sheets - Shear: it is assumed that the shear force is partly absorbed by the supporting sheets and partly by the resin. The data given in Tables 1 and 2 should be treated as indicative. It is left up to the designer to check them in relation to specic applications. INSTRUCTIONS FOR FITTING The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces.

* On request, Isopan can supply polyurethane resins that pass the strictest re reaction tests, to obtain panels of class M1 according to the French standard P 92-501, B1 or B2 according to the German DIN 4102. 1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: WALL USE UNDER NORMAL CONDITIONS Screw - self-tapping, 6.0 mm for 3 mm thick supports; - self-threading, 6.3 mm for < 3 mm thick supports, with incorporated false washer; length: panel nominal thickness +10 mm One for each panel for all supports WALL USE IN CONDITIONS OF STRONG DEPRESSION Screw-plate 20 x 60 mm - self-tapping, 6.0 mm for 3 mm thick supports; - self-threading, 6.3 mm for < 3 mm thick supports, without incorporated false washer; length: panel nominal thickness +10 mm One for each panel for all supports

Quantity:

For panels with aluminium supports, please require ISOPANs special instructions.

THERMAL INSULATION
K
W/m2 K kcal/m2 h C

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing Sheets closing L 3 m 5 mm L > 3 m 10 mm 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm

NOMINAL THICKNESS OF PANEL mm


40 0.50 0.44 50 0.40 0.35 60 0.34 0.30 80 0.26 0.23 100 0.21 0.18

Where L is the length and D is the thickness of the panels.

20

INSTALLATION EXAMPLE

VERTICAL USE

30 mm

HORIZONTAL USE F

OVERLOADS - SPANS
EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 345 310 285 265 250 235 405 360 335 310 295 280

The Isopan Spa recommends during the installation to utilize an appropriate steel plate for xing distribution stresses.

SHEET STEEL THICKNESS 0.5 mm


PANEL THICKNESS mm 40 50 60 MAX. SPAN cm 455 410 380 355 335 315 545 490 450 420 395 375 635 570 525 490 460 435 395 355 330 310 290 275 460 420 385 360 340 325 80 100 40 PANEL THICKNESS mm 50 60 MAX. SPAN cm 525 475 435 410 385 370 620 565 520 485 460 435 725 655 605 565 535 510 80 100

ALUMINIUM SHEETS - THICKNESS 0.6 mm


EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 260 235 215 200 190 180 300 270 250 235 220 210 PANEL THICKNESS mm 40 50 60 MAX. SPAN cm 340 310 285 265 250 240 405 365 335 310 295 280 470 430 390 365 345 325 295 265 245 230 220 210 345 310 290 270 255 245 80 100 40 PANEL THICKNESS mm 50 60 MAX. SPAN cm 390 355 325 305 290 275 460 415 385 360 340 325 535 485 445 420 395 375 80 100

In the planning stage, together with the analysis of static load, the holding of the joint has to be taken into consideration.

WEIGHTS OF PANELS
50 10.70 60 11.10 80 11.90 100 12.70

WEIGHT
40 kg/m2

NOMINAL THICKNESS OF PANEL mm


10.30

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 micro-ribbed in galvanised steel or aluminium, with 5 m primer and 20 m paint micro-striped in galvanised steel or aluminium, with 5 m primer and 20 m paint Coeff. of thermal transmission: K = W/m2 K , colour kcal/m2 h C ; type of screw ; quantity , colour mm thick, prepainted visible side: line mm thick, prepainted visible side: line

Highly insulating rigid expanded polyurethane resin-based; Total density kg/m3 40 10% type of xing device

21

ISOCLASS 1000
A panel designed for wall use. It features a patented system for xing panels and slotting them together, and offers a finished product with good looks and durability. The xing system, which is concealed in the joints, makes the design of the prole modular.

125 22 panel thickness

1000

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Rolled steel sheets galvanised by the Sendzimir process (UNI EN 10326-UNI EN 10327) - Rolled steel sheets galvanised and prepainted by the Coil Coating process - Rolled sheets in aluminium alloy, with natural nish, embossed and prepainted (EN 485) - Prepainting carried out by continuous process, with thickness on the visible side of 5 microns of primer and 20 microns of paint, in the following series: PS-PX-PVDF (special products can be supplied on request, with extremely high anti-corrosion properties). - Rolled copper sheets (DIN 1787/17670/1791). INSULATING CORE Rigid foam with high insulating power with a base of polyurethane (PUR) or polyisocyanurate (PIR) resins, both self-extinguishing*, meeting the following qualitative standards: - reference thermal conductivity at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - adhesion value to supports: 0.10 N/mm2 - compression value at 10% deformation: 0.11 N/mm2. THERMAL INSULATION The heat transmission coefcients K stated in the sheet should be treated as useful design values, at 10C; the calculation takes account of the two laminar resistances, external and internal, and of the calculated useful thermal

conductivity at 10C (obtained by applying to m the loading m = 10%): = 0.022 W/mK. LOADING - Deformation: a maximum curvature of 1/200 L is permissible - Deection: it is assumed that the deecting force is completely absorbed by the supporting sheets - Shear: it is assumed that the shear force is partly absorbed by the supporting sheets and partly by the resin. The data given in Tables 1 and 2 should be treated as indicative. It is left up to the designer to check them in relation to specic applications. INSTRUCTIONS FOR FITTING The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.
* On request, Isopan can supply polyurethane resins that pass the strictest re reaction tests, to obtain panels of class M1 according to the French standard P 92-501, B1 or B2 according to the German DIN 4102. 1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: WALL USE UNDER NORMAL CONDITIONS Screw - self-tapping, 6.0 mm for 3 mm thick supports; - self-threading, 6.3 mm for < 3 mm thick supports, with incorporated false washer; length: panel nominal thickness +10 mm One for each panel for all supports WALL USE IN CONDITIONS OF STRONG DEPRESSION Screw-plate 20 x 60 mm - self-tapping, 6.0 mm for 3 mm thick supports; - self-threading, 6.3 mm for < 3 mm thick supports, without incorporated false washer; length: panel nominal thickness +10 mm One for each panel for all supports

Quantity:

For panels with aluminium supports, please require ISOPANs special instructions.

THERMAL INSULATION
K
W/m2 K kcal/m2 h C

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing Sheets closing L 3 m 5 mm L > 3 m 10 mm 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm

NOMINAL THICKNESS OF PANEL mm


72 0,34 0,30 92 0,26 0,23 102 0,23 0,20

Where L is the length and D is the thickness of the panels.

22

VERTICAL USE

HORIZONTAL USE

A
F

30 mm

B
F

The Isopan Spa recommends during the installation to utilize an appropriate steel plate for xing distribution stresses.

OVERLOADS - SPANS

Example of modular assembly of the Isoclass 1000 panel with the Isoparete Pliss 1000 panel
Isoclass 72 mm combinable with Isoparete Pliss 60 mm Isoclass 92 mm combinable with Isoparete Pliss 80 mm

SHEET STEEL THICKNESS 0,5 mm EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 daN/m2 58 78 98 117 137 156 449 405 372 348 328 312 PANEL THICKNESS mm 72 92 MAX. SPAN cm 543 490 451 421 398 378 587 529 488 456 430 409 516 466 431 404 382 364 102 PANEL THICKNESS mm 72 92 MAX. SPAN cm 622 563 520 488 461 440 673 608 562 527 499 476 102

F INSTALLATION EXAMPLE

120 140 160

SHEET STEEL THICKNESS 0,6-0,5 mm EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 120 140 160 daN/m2 58 78 98 117 137 156 464 417 384 358 338 321 PANEL THICKNESS mm 72 92 MAX. SPAN cm 560 504 465 434 409 389 605 545 503 469 443 421 532 481 445 416 393 375 102 PANEL THICKNESS mm 72 92 MAX. SPAN cm 641 580 536 502 475 453 693 627 580 543 514 490 102

In the planning stage, together with the analysis of static load, the holding of the joint has to be taken into consideration.

WEIGHTS OF PANELS
92 11,9 102 12,3

STEEL WEIGHT THICKNESS mm


0,5 kg/m2

NOMINAL THICKNESS OF PANEL mm


72 11,1

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 sinusoidal wave proling in galvanised steel or aluminium, with 5 m primer and 20 m paint micro-striped in galvanised steel or aluminium, with 5 m primer and 20 m paint Coeff. of thermal transmission: K = W/m2 K , colour kcal/m2 h C ; type of screw ; quantity , colour mm thick, prepainted visible side: line mm thick, prepainted visible side: line

Highly insulating rigid expanded polyurethane resin-based; Total density kg/m3 40 10% type of xing device

23

ISOFRIGO 1000
A self-supporting insulated metal panel, ver y versatile and easy to fit. Its extremely high performance as thermal insulation, and the excellent quality of its jointing and xing system, make it particularly suitable for the construction of walls, ceilings, cladding and infill in storages and refrigerated cells at negative or positive temperature, conservation chambers, controlled temperature and processing rooms.
effective width

thickness

effective width available in two sizes: 1000 - 1155 mm

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Rolled steel sections galvanised by the Sendzimir process (UNI EN 10326UNI EN 10327) - Rolled steel sections galvanised and prepainted by the Coil Coating process - Rolled sections in aluminium alloy, with natural and prepainted nish (EN 485) - Prepainting carried out by continuous process, with thickness, on the visible side, of 5 microns of primer and 20 microns of paint, in the following series: PS-PX-PVDF (special products can be supplied on request, with extremely high anti-corrosion properties). - Prepainted PS and PVC coatings (standard colours), complying with current regulations on contact with foodstuffs. INSULATING CORE Rigid foam with high insulating power, with a base of Self-extinguishing* polyurethane resins (PUR), meeting the following qualitative standards: - reference thermal conductivity at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - adhesion to supporting surfaces: 0.10 N/mm2 - compression pressure required to produce 10% deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of heat transmission K stated in the sheet should be taken as usable for design purposes, at 10C; the calculation takes account of the two laminar resistances, external and internal, and of the thermal conductivity

usable for calculation purposes at 10C (obtained by applying the increment m = 10% to m): = 0.022 W/mK. LOADING - Deformation: a maximum curvature of 1/200 L is permissible - Deection: it is assumed that the bending moment is completely absorbed by the supporting sheets - Shear: it is assumed that the shear force is partly absorbed by the supporting sheets and partly by the resin. The data given in the tables are to be considered indicative only. It is left up to the designer to check them in relation to specic applications. INSTRUCTIONS FOR FIXING The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.
* On request, Isopan can supply polyurethane resins capable of passing the most severe tests for reaction to re, in order to obtain panels of class M1 in terms of the French standard P 92-501, and B1 or B2 in terms of the German standard DIN 4102. 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacture.

EXAMPLES OF APPLICATIONS

Refrigerated cells constructed with Isofrigo panels.

24

IMPORTANCE OF SEALING THE JOINT (vapour barrier)


When the refrigerated cell comes into operation and the temperature falls, the internal depression produced by the low temperature favours the passage of air from the outside to the inside of the cell. If the seal is less than perfect, the moist air could succeed in crossing the joint and reach the area of the inner face of the panel, favouring the appearance of condensation. When the condensation encounters negative temperatures, it could cause the formation of ice. The ice damages the structure of the joint, causing a further loss of efciency in the cell, and in the most serious cases, compromises the adhesion between the sheets and the insulating core. Having conducted thorough analysis of these phenomena, Isopan recommends using suitable proles and seals, such as expanding gaskets or similar sealants, to obtain good waterproof performance from the joint.
Low temperature cell

F
2 1 2

* ac a a a

1 2

- Standard sealing gasket applied in production

- Predisposition for the setting of gaskets or sealing

to be installed while assembling

* Not sufcient for cell operating temperatures lower than 0C.


FACINGS IN STEEL, THICKNESS 0.5 mm

PERMISSIBLE LOADS

EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 120 140 160 545 490 450 420 395 375 635 570 525 490 460 435 80 100 PANEL THICKNESS mm 120 715 640 590 550 520 490 150 790 700 640 590 545 515 180 845 740 670 610 555 525 200 870 765 690 625 560 530 80 620 565 520 485 460 435 100 725 655 605 565 535 510 MAX. SPAN cm PANEL THICKNESS mm 120 805 735 680 635 600 575 150 905 805 740 685 640 605 180 975 865 800 735 675 630 200 1035 920 855 775 700 650 MAX. SPAN cm

with load depression at 20 kg/m2 - with load depression at 30 kg/m2

SERVICE STATIC PROPERTIES


SHEET STEEL THICKNESS 0.5 mm CONCENTRATED LOAD
80 kg NOMINAL THICKNESS OF PANEL mm 100 120 150 180 200 MAX. SPAN cm 525 640 765 930 1045 1130

SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD


kg/m2 WEIGHT + 20 WEIGHT + 30 600 545 690 630 NOMINAL THICKNESS OF PANEL mm 80 100 120 770 705 150 900 820 180 200 MAX. SPAN cm 1010 1100 925 1020

WEIGHT + 120

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing Sheets closing L3m L>3m 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm

THERMAL INSULATION
K
80 W/m2 K kcal/m2 h C 0,26 0,23

NOMINAL THICKNESS OF PANEL mm


100 0,21 0,18 120 0,18 0,15 150 0,14 0,12 180 0,12 0,10 200 0,11 0,09

WEIGHTS OF PANELS
STEEL THICKNESS mm
0,5

WEIGHT
kg/m2

NOMINAL THICKNESS OF PANEL mm


80 11,3 100 12,1 120 12,9 150 13,7 180 14,5 200 15,3

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: Expanding gasket: mm mm 1000/1155 micro-corrugated in galvanised steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint micro-corrugated in galvanised steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint Coeff. of thermal transmission: K = type of xing rolls W/m2 K kcal/m2 h C ; type & dia. of screws ; quantity (m) ; quantity colour colour prepainting on visible side series prepainting on visible side series

rigid foam with high insulating power, on a base of polyurethane resins, total density kg/m3 40 10%

25

ISOFIRE WALL 1000


A panel designed for wall use. It features a core of mineral fibre which ensures that the product is incombustible, besides delivering excellent thermal insulation. It was created to satisfy the growing demand for improved performance in re behaviour, and is suitable for constructing external walls and internal dividing walls. The particular design of joint means that the screw is concealed inside the panel, thus giving the panel an excellent aesthetic effect.

thickness 1000

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Rolled steel sheets galvanised by the Sendzimir process (UNI EN 10326-UNI EN 10327) - Rolled steel sheets galvanised and prepainted by the Coil Coating process - Rolled sheets in aluminium alloy, with natural nish, embossed and prepainted (EN 485) - Prepainting carried out by continuous process, with thickness on the visible side of 5 microns of primer and 20 microns of paint, in the following series: PS-PX-PVDF (special products can be supplied on request, with extremely high anti-corrosion properties). INSULATING CORE Insulating layer manufactured from high-density mineral bres (100 kg/m3, m = 0.040 W/mK at 10 C). LOADING - Deformation: a maximum curvature of 1/200 L is permissible - Deection: it is assumed that the deecting force is completely absorbed by the supporting sheets

- Shear: it is assumed that the shear force is partly absorbed by the supporting sheets and partly by the insulation. The data given in the tables are to be considered indicative. It is left up to the designer to check them in relation to specic applications. INSTRUCTIONS FOR FIXING The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. The greatest recommended length for safe movement of the mineral bre panels is 6000 mm. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces.

1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacture.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: USE IN WALLS screw-washer in PVC (*) self-piloting 6.0 mm for bearing thickness 3 mm self-tapping 6.3 mm for bearing thickness < 3 mm length: panel nominal thickness + 010 mm Two per panel for end xings One per panel for intermediate xings

Quantity:

(*) In cases of strong depression we recommend tting a plate under the screw. For panels with supports in aluminium, please ask for special instructions.

26

VERTICAL USE

HORIZONTAL USE

30 mm

B
F

The Isopan Spa recommends during the installation to utilize an appropriate steel plate for xing distribution stresses.

OVERLOADS - SPANS

GALVANIZED STEEL SHEETS THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 120 150 daN/m2 58 78 98 117 147 390 325 260 215 170 495 430 385 345 280 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 555 480 430 390 345 605 525 470 430 385 655 565 510 470 425 420 360 290 240 190 530 480 410 340 270 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 600 540 455 395 310 660 580 490 420 340 700 600 520 445 375 120 150

In the planning stage, together with the analysis of static load, the holding of the joint has to be taken into consideration.

THERMAL INSULATION
K
W/m K
2

WEIGHTS OF PANELS
100 0,4 0,35 120 0,33 0,30 150 0,27 0,24

NOMINAL THICKNESS OF PANEL mm


50 0,75 0,67 80 0,5 0,44

STEEL THICKNESS
0,5 0,6

WEIGHT
kg/m
2

NOMINAL THICKNESS OF PANEL mm


50 12,8 14,50 80 15,5 17,20 100 17,3 19,00 120 19,5 21,40 150 22,7 24,40

kcal/m2 h C

kg/m2

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


FIRE RESISTANCE (circular letter number 91, dated 14th September 1961) Panels ISOFIRE WALL PLISS 1000 field-tested have obtained the following results: REI level 60 for 80 mm thick panels
DEVIATIONS mm
Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing Sheets closing L 3 m 5 mm L > 3 m 10 mm 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 microribbed, in galvanised steel/aluminium, thickness mm with 5 microns of primer and 20 microns of painting microribbed, in galvanised steel/aluminium, thickness mm with 5 microns of primer and 20 microns of painting carried out by high-density mineral bres (100 kg/m3) W/m2, K kcal/m2 h C ; type of screw ; quantity type of xing device Coeff. of thermal transmission: K = , prepainted visible side: line , colour , prepainted visible side: line , colour , ,

27

ISOFIRE WALL 1000


This panel is designed for sloped wall use. Its mineral fibre core guarantees incombustibility, as well as assuring an excellent thermal insulation. ISOFIRE WALL 1000 was designed to meet the growing requirements in terms of re behaviour and is indicated for both external and internal partition walling.

1000

thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SURFACES - Sendzimir galvanised steel sheet (UNI EN 10326-UNI EN 10327). - Galvanised steel sheet, pre-painted by means of a Coil Coating process. - Aluminium alloy sheet, mill nish, stucco embossed or pre-painted (EN 485). - Continuous pre-painting process with a 5 m thick primer and a 20 m paint on the items visible side. Available in the following lines: PS-PX-PVDF (On request, ISOPAN can also supply very anticorrosive special products). INSULATING LAYER Insulating layer made of high-density mineral bres (100 kg/m3, m = 0.040 W/mK at 10 C). LOAD LIMITS - Deformation: a deection equal to or lower than 1/200 L of the free span is admitted. - Deection: it is assumed that the bending stress is completely absorbed by the steel support sheets. - Cut: it has been assumed that the cutting stress is absorbed partly by the steel support sheets and partly by the insulation material.

The data specied in tables 1 and 2 are to be considered as indicative. The designer will have to verify and adjust such details with regard to every specic application. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. The maximum recommended length for correctly handling mineral bre panels is 6000 mm. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces.

1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: WALL APPLICATION PVC screw-washer (*) self-tapping. 6.0 mm for 3 mm thick supports; self-threading, 6.3 mm for < 3 mm thick supports, with an incorporated drive washer; length: panel nominal thickness + 20 30 mm Two for each panel (terminal supports); one for each panel (intermediate supports)

Quantity:

(*) In the event of a considerable structural low, it is advisable to interpose a 50 mm washer. For panels with aluminium or copper supports, please require ISOPANs special instructions.

28

OVERLOADS - SPANS
GALVANIZED STEEL SHEETS THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 150 daN/m2 58 78 98 117 147 365 305 245 200 160 460 400 360 325 260 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 520 450 400 365 320 565 490 440 400 360 610 530 480 440 395 395 340 275 225 180 495 450 385 320 250 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 565 510 425 370 285 620 545 460 390 315 655 565 490 415 345 120 150

GALVANIZED STEEL SHEETS THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m2 60 80 100 120 150 daN/m2 58 78 98 117 147 390 325 260 215 170 495 430 385 345 280 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 555 480 430 390 345 605 525 470 430 385 655 565 510 470 425 420 360 290 240 190 530 480 410 340 270 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 600 540 455 395 310 660 580 490 420 340 700 600 520 445 375 120 150

F WEIGHTS OF PANELS F F THERMAL INSULATION


K
W/m2 K kcal/m2 h C

STEEL THICKNESS
0,5 0,6

WEIGHT
kg/m
2

NOMINAL THICKNESS OF PANEL mm


50 12,8 14,50 80 15,5 17,20 100 17,3 19,00 120 19,5 150 22,7

kg/m2

21,40 24,40

NOMINAL THICKNESS OF PANEL mm


50 0,75 0,67 80 0,5 0,44 100 0,4 0,35 120 0,33 0,30 150 0,27 0,24

On request, ISOPAN can issue the following re behaviour certications: FIRE REACTION Panels ISOFIRE WALL 1000 field-tested in accordance with the Ministerial Decree dated 26th June 1984, have been granted the re reaction category 0-0. FIRE RESISTANCE Panels ISOFIRE WALL 1000 eld-tested have obtained the following results: REI level 30 for 50 mm thick panels (in accordance with circular letter n. 91 dated 14th september 1961) REI level 60 for 80 mm thick panels (in accordance with circular letter n. 91 dated 14th september 1961) REI level 120 for 100 mm thick panels. (in accordance with circular letter n. 91 dated 14th september 1961) EI 60 for 80 mm thick panels (in accordance with EN 13501-2) EI 90 for 120 mm thick panels (in accordance with EN 13501-2) EI 180 for 150 mm thick panels (in accordance with EN 13501-2)

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing Sheets closing L3m L>3m 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 microribbed, in galvanised steel/aluminium, thickness mm with 5 microns of primer and 20 microns of painting microribbed, in galvanised steel/aluminium, thickness mm with 5 microns of primer and 20 microns of painting carried out by high-density mineral bres (100 kg/m3) W/m2, K kcal/m2 h C ; type of screw ; quantity type of xing device Coeff. of thermal transmission: K = , prepainted visible side: line , colour , prepainted visible side: line , colour , ,

29

ISOFIRE WALL - FONO


The range of FONO panels was designed to satisfy the increasing demands for performance in sandwich panels in terms of soundproong, guaranteeing the non-combustibility of the product at all times. The ISOFIRE WALL FONO is used for wall panelling.

1000

thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Sendzimir galvanised steel sheet (UNI EN 10326-UNI EN 10327). - Galvanised steel sheet, pre-painted by means of a Coil Coating process. - Aluminium alloy sheet, mill nish, stucco embossed or pre-painted (EN 485). - Continuous pre-painting process with a 5 m thick primer and a 20 m paint on the items visible side. Available in the following lines: PS-PX-PVDF (On request, ISOPAN can also supply very anticorrosive special products). INSULATING LAYER Insulating layer made of high-density mineral bre (100 kg/m3, m = 0.040 W/mK at 10C). LOAD LIMITS - Deformation: a deection equal to or lower than 1/200 L of the free span is admitted.

- Deection: it is assumed that the bending stress is completely absorbed by the steel support sheets. - Cut: it has been assumed that the cutting stress is absorbed partly by the steel support sheets and partly by the insulation material. The data specied in tables 1 and 2 are to be considered as indicative. The designer will have to verify and adjust such details with regard to every specic application. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.

1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: USE OF ISOFIRE WALL - FONO screw-PVC washer (*) self-tapping, 6.0 mm for 3 mm thick supports; self-threading, 6.3 mm for < 3 mm thick supports, with false incorporated washer; length: panel nominal thickness + 20 30 mm Two for each panel (terminal supports); one for each panel (intermediate supports)

Quantity:

(*) in the case of strong depression the use of a 50 mm washer is recommended. For panels with aluminium or copper supports, please ask for specic instructions.

30

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 150 daN/m2 58 78 98 117 147 270 215 175 155 123 380 330 275 235 195 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 430 365 330 290 235 460 385 355 315 255 484 399 374 334 269 340 295 260 240 218 435 370 335 305 268 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 480 425 370 340 305 510 460 390 360 331 530 485 405 375 350 120 150

F WEIGHTS OF PANELS
STEEL THICKNESS
0,6

WEIGHT
kg/m2

NOMINAL THICKNESS OF PANEL mm


50 12,82 80 15,52 100 17,32 120 19,72 150 22,72

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm

Length Effective width

L3m L>3m 2 mm

5 mm 10 mm

THERMAL INSULATION
K
W/m K
2

Thickness Deviation from perpendicularity Misalignment of internal metal facing Sheets closing

D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm

NOMINAL THICKNESS OF PANEL mm


50 0,75 0,67 80 0,5 0,44 100 0,4 0,35 120 0,33 0,30 150 0,27 0,24

kcal/m2 h C

Where L is the length and D is the thickness of the panels.

On request ISOPAN can issue the following certications concerning noise behaviour: SOUND INSULATION Rw = 29 dB; Rw = 33 dB; Rw = 35 dB - (Wall fono, 50, 80 and 100 thick) NOISE ABSORPTION Weighted sound absorption coefcient w = 1 FIRE RESISTANCE (circular letter number 91, dated 14th September 1961) Panels ISOFIRE WALL-FONO 1000 eld-tested have obtained the following results: REI level 60 for 100 mm thick panels

31

ISODOGA 1000
A panel designed for use in false walls and false ceilings. Characterized by the same Isoparete external panel as well as the same system interlocking and xing system. The joint guarantees a high level of air retention; for particularly critical situations a washer may be inserted. Its low cost allows very economic solutions, maintaining at the same time its aesthetic prerogatives.

thickness

1000

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0.10 N/mm2 - value of compression at 10% of deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the

thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK. WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established - Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.
* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: FOR USE IN STANDARD SITUATIONS screw - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel - 510 mm One per panel for all supports FOR USE IN STRONG DEPRESSION screw-plate 20x60 mm - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel - 510 mm One per panel for all supports

Quantity:

32

OVERLOADS - SPANS
SHEET STEEL EVENLY DISTRIBUTED LOAD
kg/m2 0 10 20 50 100 daN/m2 0 10 19 49 98 300 210 180 135 110 0.5 NOMINAL THICKNESS STEEL mm 0.6 300 220 190 145 120 0.7 300 230 200 155 130 0.8 300 240 210 165 140 0.5 380 260 220 170 135 MAX. SPAN cm NOMINAL THICKNESS STEEL mm 0.6 380 270 230 180 150 0.7 380 280 240 190 160 0.8 380 290 250 200 170 MAX. SPAN cm

WEIGHTS OF PANELS
WEIGHT
kg/m2

NOMINAL THICKNESS OF PANEL mm


30 5.90 35 6.10

THERMAL INSULATION
K
W/m2 K kcal/m2 h C

DIMENSIONAL TOLERANCES
DEVIATIONS mm
Length Effective width Thickness Orthometry and rectangularity 10 1 2 3 35 0.56 0.49

NOMINAL THICKNESS OF PANEL mm


30 0.64 0.57

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 microridged in galvanized steel thickness mm with 5 microns of primer and 20 microns of paint natural, lacquered and embossed centesimal aluminium made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10% W/m2 K kcal/m2 h C ; screw type and shank ; qty type of xing prevarnished on the visible side series colour

Coeff. of thermal transmission: K =

33

2010 innovations

The Isodomus panel has been created in the REALE ANTICO colour
In order to respond to the many requests in the Mediterranean market, Isopan has obtained the homologation for realisation of the Isodomus panel in the REALE ANTICO colour, which offers the following advantages: No glossy effect, thanks to the satin nish on the surface of the panel; Better matching with the nishing of roof tiles and shingles; High resistance of the aged tile colour, thanks to the extremely high quality of the paint used; Innovative colouring that is unequalled on the market.

Roong panels

35

ISODOMUS
(INSULATED)
ISODOMUS represents the greatest evolution in terms of aesthetics for insulated roofing panels used in civil construction. ISODOMUS Insulated is an expanded polyurethane panel with an architectural roof tile pattern, which allows it to be used as a functional roof covering, while at the same time being greatly appreciated for its appearance; it is lightweight, safe, easy to install and waterproof, in order to satisfy the strictest landscape regulations. ISODOMUS Insulated is the perfect combination of the best ISOPAN technology and traditional roof coverings, guaranteeing the high thermal insulation values that are typical of polyurethanebased products.

ISODOMUS

Guarnizione Seal 50

Exterior skin Lamiera esterna

Polyurethane Poliuretano

200

200 Lamiera skin InteriorInterna

200 1000

200

200

ISODOMUS CLASSIC

Seal Guarnizione
50

Lamiera esterna Exterior skin

Polyurethane Poliuretano

1000
Lamiera interna / alluminio centesimale felt-paper Interior skin aluminium foil / / cartonfeltro

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SURFACES - Sendzimir galvanised steel sheet (UNI EN 10326-UNI EN 10327). - Galvanised steel sheet, pre-painted by means of a Coil Coating process. - Aluminium alloy sheet, mill nish, stucco embossed or pre-painted (EN 485). - Continuous pre-painting process with a 5 m thick primer and a 20 m paint on the items visible side. Available in the following lines: PS-PX-PVDF (On request, ISOPAN can also supply very anticorrosive special products). - Copper sheet (DIN 1787/17670/1791). INSULATING LAYER Highly insulating rigid expanded polyurethane resin-based self-extinguishing materials (PUR), with the following quality standards: - thermal conductivity at 10C: m = 0.020 W/mK - total density: 42 kg/m3 10% - support adhesion value: 0.10 N/mm2 - compression value at 10% deformation: 0.11 N/mm2 THERMAL INSULATION The thermal transmission coefcients K specied in the product data sheet are to be considered as design specications at 10 C; reckoning takes into account the two laminar resistances - external and internal - and useful thermal conductivity calculated at 10 C (obtained by applying the increase factor m = 10% to m): = 0.022 W/mK. INSTALLATION, MAINTENANCE AND INSPECTION Regulation reference: UNI 10372, with the following remarks: - We recommend to install the product with a minimum slope of 11%, to allow a correct water drain. - Where roof walkability should be necessary, we recommend not to over pass a span of 2.4 m between the main supports (Minimum free span available for a 40 mm th, Isodomus panel) - For a long durability of the product, we recommend to check periodically the roof covering, and to remove any possible leafage or other sediments, that could cause stagnation.
1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

36

INSTALLATION EXAMPLES

LOAD LIMITS
P I P I

Insulation thickness (mm) 40 40 40

Distance in between xing points (mm)


1050 400 480 290 420 1400 285 360 240 300 1750 215 280 230 230 2100 160 230 170 165 2450 115 200 120 110 2800* 90 150 70 80 3150* 65 130 55 60 3500* 50 110 40 45

External steel surface th. 0.5 mm Internal steel surface th. 0.4 mm External aluminium surface th. 0.6 mm Internal steel surface th. 0.4 mm External copper surface th. 0.5 mm Internal steel surface th. 0.4 mm

The values shown in red have no limit conditions as far as deection is concerned.

* On grey background lights for preventing pedestien access.

The values shown, taken from laboratory tests carried out on panels not xed to any support, consider a suitable safety coefcient. During inspections for maintenance and cleaning it is advisable to use suitable precautions in order not to crush the sheet near the deepest curves. Rubber-soled shoes should be worn and care must be taken in the use of tools and equipment, as these could scratch the paint and underlying galvanization, which could lead to rusting. The covering should be inspected periodically (at least once a year) and any sediment that could cause unwanted water stagnation should be removed. The data indicated in tables are to be considered indicative. The project menager should check this data according to the specic applications.

STANDARD LENGTHS
STANDARD PANEL LENGTHS
mm 2100 8400 2450 8750 2800 9100 3150 9450 3500 3850 4200 4550 10500 4900 10850 5250 5600 5950 6300 11900 6650 12250 7000 7350 7700 8050 13300 9800 10150 11200 11550 12600 12950

WEIGHTS OF PANELS
WEIGHT NOMINAL THICKNESS OF PANEL mm
40 kg/m
2

FIXING EXAMPLES

50 11,30

60 11,70

10,90

DIMENSIONAL TOLERANCES
(in compliance with EN 14509)
DEVIATIONS mm
Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing L 3 m 5 mm L > 3 m 10 mm 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm

Where L is the length and D is the thickness of the panels.

THERMAL INSULATION
L 70 350 350 350 350 280

K
W/m2 K kcal/m2 h C

NOMINAL THICKNESS OF PANEL mm


40 0,36 0,32 50 0,31 0,27 60 0,27 0,23

DRAFT OF SPECIFICATIONS
mm outside ribbing mm 1000 corrugated false roof tiles (rib height 50 mm, distance between ribs 200 mm) in galvanised steel/aluminium/copper thickness mm pre-painted on visible side series with 5 m of primer and 20 m of paint colour micro-ribbed in galvanised steel/aluminium/copper thickness mm pre-painted on visible side series Internal support: with 5 m of primer and 20 m of paint colour in stiff high insulating, expanded polyurethane resin, total density 42 10% kg/m3 Insulation: Coeff. of thermal transmission: K = W/m2 K kcal/m2 h C Fixing: type of xing: type of screw: quantity: Nominal thickness: Effective width: External support:

37

ISOVELA 1000
Roofing panel with 6 sinusoidal waves, with thermal insulation, ideal for large areas of roof, with high-quality appearance and easy to fit. Ideal applications: agricultural and industrial buildings and in sanitation, replacement for asbestos bre roofs. Available in a wide range of colours, both gloss and anti-reective mat (terracotta, slate grey and green).

1000 200

50 average thickness

nominal thickness +30 mm

AVERAGE THICKNESS OF PANEL INSULATION [mm]: 60 - 70 - 80


NOTES FOR CONSULTING THE DATA SHEET (for any information not given, please refer to the AIPPEG regulations1)
METAL SUPPORTS (FACING SHEETS) - Rolled steel sheets galvanised by the Sendzimir process (UNI EN 10326-UNI EN 10327) - Rolled steel sheets galvanised and prepainted by the Coil Coating process - Rolled sheets in aluminium alloy, with natural nish, embossed and prepainted (EN 485) - Prepainting carried out by continuous process, paint thickness on the face side: 5 microns of primer and 20 microns of paint, in the following series: PS-PX-PVDF (special products can be supplied on request, with extremely high anti-corrosion properties). - Rolled copper sheets (DIN 1787/17670/1791) INSULATING CORE Rigid foam with high insulating power with a base of self-extinguishing * polyurethane resins (PUR), meeting the following quality standards: - reference thermal conductivity at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - adhesion value to supports: 0.10 N/mm2 - compression value at 10% deformation: 0.11 N/mm2 THERMAL INSULATION The heat transmission coefcients K stated in the sheet should be treated as useful design values, at 10C; the calculation takes account of the two laminar resistances, external and internal, and of the calculated useful thermal conductivity at 10C (obtained by applying to m the loading m = 10%): = 0.022 W/mK. LOADING - Deformation: a maximum curvature of 1/200 L is permissible - Deection: it is assumed that the deecting force is completely absorbed by the supporting sheets - Shear: it is assumed that the shear force is partly absorbed by the supporting sheets and partly by the resin. The data given in the tables are to be considered indicative. It is left up to the designer to check them in relation to specic applications. INSTRUCTIONS FOR FIXING The designer should evaluate the conditions of use in relation to the local climatic situation. Special precautions must be taken over xing panels with supports in aluminium, copper or steel in dark colours. For further information, please see the RECOMMENDATIONS FOR FITTING RIBBED SHEETS AND INSULATED METAL PANELS issued by AIPPEG, and FITTING MANUAL AND FIXINGS by Isopan SpA.
* On request, Isopan can supply polyurethane resins capable of exceeding the most severe re reaction tests, resulting in panels conforming to Class 1 in accordance with French standard P 92-501, B1 or B2 in accordance with German standard DIN 4102. 1- AIPPEG: Italian Association of Producers of Ribbed Panels and Fittings.

INSTRUCTIONS FOR FIXING


Type of xing Type and length of bolt ROOFING APPLICATIONS screw-washer in PVC - Capping - Gasket - self-piloting 6.0 mm for bearing thickness 3 mm - self-tapping 6.3 mm for bearing thickness < 3 mm with false washer incorporated length: panel nominal thickness + 7080 mm One per rib for end xings or head-end overlap One every two ribs for intermediate xings USE IN WALLS screw-washer in PVC (*) - self-piloting 6.0 mm for bearing thickness 3 mm - self-tapping 6.3 mm for bearing thickness < 3 mm with false washer incorporated length: panel nominal thickness + 2030 mm One per rib for end xings or head-end overlap One every two ribs for intermediate xings

Quantity

(*) In cases of strong depression we recommend tting a 50 mm washer. For panels with supports in aluminium or copper, please ask for special instructions.

38

OVERLOADS - SPACING
STEEL SHEETS: THICKNESSES EXT 0.5 mm - INT 0.5 mm UNIFORMLY DISTRIBUTED LOAD
kg/m2 80 120 150 200 250 daN/m2 78 117 147 196 245 440 377 346 309 282 NOMINAL THICKNESS OF PANEL mm 60 70 MAX SPACING cm 480 412 379 338 309 519 446 410 367 335 507 439 405 364 329 80 SPESSORE NOMINALE DEL PANNELLO mm 60 70 MAX SPACING cm 553 478 441 397 359 597 517 477 430 388 80

STEEL SHEETS: THICKNESSES EXT 0.6 mm - INT 0.5 mm UNIFORMLY DISTRIBUTED LOAD
kg/m2 80 120 150 200 250 daN/m2 78 117 147 196 245 455 390 358 319 291 NOMINAL THICKNESS OF PANEL mm 60 70 MAX SPACING cm 496 426 391 349 318 536 460 423 378 345 525 454 419 376 346 80 NOMINAL THICKNESS OF PANEL mm 60 70 MAX SPACING cm 571 494 456 410 378 617 534 493 444 408 80

WEIGHT OF PANELS
THICKNESS WEIGHT NOMINAL THICKNESS OF PANEL mm OF SHEETS 60 70 80
0,5 0,6 kg/m2 kg/m2 11,4 13,2 11,8 13,6 12,2 14,0

DIMENSIONAL TOLERANCES (in accordance with EN 14509)


DEVIATION mm
Length L3m L>3m Useful width Thickness 2 mm D 100 mm 2 mm D > 100 mm 2 % Deviation from perpendicular Misalignment of internal metal facings Coupling of lower sheets 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm

THERMAL INSULATION
K
W/m2 K kcal/m2 h C

NOMINAL THICKNESS OF PANEL mm


60 0,34 0,29 70 0,29 0,25 80 0,26 0,22

Where L is the length and D is the thickness of panels.

SCHEME FOR TENDER CONTRACTS


Nominal thickness Useful width External support Internal support Insulation Heat transmiss. coeff. Fixings mm mm 1000 ribbed (ribs 50 mm high, spacing 200 mm) in galvanised steel/aluminium/copper thickness mm face side standard with 5 microns of primer and 20 microns of paint with 5 microns of primer and 20 microns of paint K= type of xing W/m2 K kcal/m2 h C ; type and length of bolt ; quantity colour colour prepainting on face side standard micro-ribbed in galvanised steel/aluminium thickness mm prepainting on outside rib

in rigid foam with high insulating power with a base of polyurethane resins, total density 4010% kg/m3

39

ISOTEGO 1000
A panel designed for pitched covering surfaces. Characterized by its high economic benets, especially when heavy working conditions are not foreseen. The product guarantees excellent aesthetic features and an excellent reliability with regards to rigidity. The possibility of using a single kind of panel for both roong and walling simplies design and material supply.
1000 500 25 40 thickness 1000 25 22

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0.10 N/mm2 - value of compression at 10% of deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK. WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established

- Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces. For lengths superior to 6.000 mm, ISOPAN suggests to make slottings in correspondence to the xing holes. As explained in the ISOPAN SpA laying and xing handbook, those slottings are supposed to absorb the major thermal expansion.

* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: FOR USE IN ROOFING PVC screw-washer - cap - gasket - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 6070 mm One for each ridge for all supports FOR USE IN WALLING PVC screw-washer (*) - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 2030 mm One for each ridge for all supports

Quantity:

(*) In the case of strong depression a 50 mm diam. washer should be interposed. For panels with aluminium or copper supports request special instructions.

40

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 80 120 150 200 250 daN/m2 78 117 147 196 245 310 265 240 215 185 360 310 280 250 220 30 PANEL THICKNESS mm 40 50 MAX. SPAN cm 410 350 320 285 250 455 390 355 320 285 535 460 415 360 320 360 310 285 255 225 415 360 330 300 265 60 80 30 PANEL THICKNESS mm 40 50 MAX. SPAN cm 475 410 375 340 300 525 455 415 375 335 610 525 475 405 360 60 80

ALUMINIUM STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m2 80 120 150 200 daN/m2 78 117 147 196 230 200 180 165 270 230 210 190 30 PANEL THICKNESS mm 40 50 MAX. SPAN cm 305 260 240 215 340 295 270 240 400 340 310 280 265 230 210 190 310 265 245 220 60 80 30 PANEL THICKNESS mm 40 50 MAX. SPAN cm 350 305 280 250 390 335 310 280 465 400 370 330 60 80

WEIGHTS OF PANELS
WEIGHT
30 kg/m2

NOMINAL THICKNESS OF PANEL mm


40 50 60 80 12.1 100 12.9 120 13.7 10.10 10.50 10.90 11.30

F DISPOSITION OF THE OVERLAP

THERMAL INSULATION
K
30 W/m2 K kcal/m2 h C 0.59 0.52

NOMINAL THICKNESS OF PANEL mm


40 0.47 0.41 50 0.39 0.34 60 0.33 0.29 80 0.25 0.22 100 0.20 0.18 120 0.17 0.15

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Left overlap
D D

Right overlap

Length Effective width

L3m L>3m 2 mm

5 mm 10 mm

INSTALLATION EXAMPLE
D L

Thickness Deviation from perpendicularity Misalignment of internal metal facing Internal sheets closing

D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm

D = mm 100-150-200 Other measurements upon agreement

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 ridged, (ridge height mm 40, span mm 500) in galvanized steel/aluminium/copper thickness mm on the visible side series with 5 microns of primer and 20 microns of paint colour colour micro-ridged in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint Coeff. of thermal transmission: K = type of xing W/m2 K kcal/m2 h C ; screw type and shank ; qty prevarnished on the visible side series prevarnished out of ridge

made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 4010%

41

ISOCOP-5 1000
A panel designed for pitched roong. It can also be used as a covering material. The possibility of using a single kind of panel for both roofing and walling simplies design and material supply. It is characterized by its strength and extreme versatility. Its high mechanical features allow it to be used in applications on large areas of unsupported spans, therefore providing a saving in the cost of supporting structures.
250 25 40 thickness 25 22

1000

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0.10 N/mm2 - value of compression at 10% of deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK. WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established

- Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. In case of aluminium alloy sheet, please notice that aluminium must be the chosen metal coating on both skins; otherwise the panel may deform and bend due to different coefcients of thermal expansion of the metal surfaces. For lengths superior to 6.000 mm, ISOPAN suggests to make slottings in correspondence to the xing holes. As explained in the ISOPAN SpA laying and xing handbook, those slottings are supposed to absorb the major thermal expansion.

* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: FOR USE IN ROOFING PVC screw-washer - cap - gasket - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 6070 mm One for each ridge for extreme supports or overlaps One every two ridges for intermediate supports FOR USE IN WALLING PVC screw-washer (*) - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 2030 mm One for each ridge for extreme supports or overlaps One every two ridges for intermediate supports

Quantity:

(*) In the case of strong depression a 50 mm diam. washer should be interposed. For panels with aluminium or copper supports request special instructions.

FIRE RESISTANCE Panels ISOCOP-5 1000 eld-tested have obtained the following results: REI 15 - RE90 for 80 mm thick panels (in accordance with EN 13501-2)

FIRE REACTION Panels ISOCOP-5 1000 eld-tested have obtained the following results: C-S3-D0 for 50 mm thick panels (in accordance with EN 13501-1)

42

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 80 120 150 200 250 daN/m2 78 117 147 196 245 345 290 265 235 210 390 335 305 270 245 30 40 PANEL THICKNESS mm 50 435 370 340 300 275 60 485 415 375 340 305 80 560 480 440 395 360 100 640 550 505 450 415 120 700 600 540 490 430 30 400 345 315 285 255 40 455 390 355 325 295 MAX. SPAN cm PANEL THICKNESS mm 50 500 430 400 360 325 60 560 485 440 400 360 80 645 555 515 460 425 100 735 635 585 525 485 120 780 680 600 550 495 MAX. SPAN cm

ALUMINIUM STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m 80 120 150 200
2

PANEL THICKNESS mm 30 250 215 200 175 40 285 245 225 205 50 MAX. SPAN cm 320 275 255 230 355 305 280 250 415 360 330 295 290 250 230 190 60 80 30

PANEL THICKNESS mm 40 330 285 265 220 50 MAX. SPAN cm 370 320 295 250 405 350 325 280 475 415 380 330 60 80

WEIGHTS OF PANELS
STEEL WEIGHT NOMINAL THICKNESS OF PANEL mm THICKNESS 40 100 120 60 50 80 30
0.4 0.4-0.5 0.5 kg/m2 kg/m2 kg/m2 8.5 9.5 8.9 9.9 9.3 9.7 10.5 11.3 12.1 10.3 10.7 11.5 12.2 12.9

F F

10.3 10.7 11.1 11.5 12.3 13.1 13.9

THERMAL INSULATION
K NOMINAL THICKNESS OF PANEL mm
30 W/m2 K kcal/m2 h C 0.55 0.48 40 0.44 0.38 50 0.36 0.32 60 0.31 0.27 80 0.25 0.22 100 0.20 0.17 120 0.17 0.15

DISPOSITION OF THE OVERLAP

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Left overlap
D

Right overlap

Length Effective width

L3m L>3m 2 mm

5 mm 10 mm

INSTALLATION EXAMPLE
D L

Thickness Deviation from perpendicularity Misalignment of internal metal facing Internal sheets closing

D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm

D = mm 100-150-200 Other measurements upon agreement

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 ridged (ridge height mm 40, span mm 250) in galvanized stee/aluminum/copper thickness mm on the visible side series with 5 microns of primer and 20 microns of paint colour colour micro-ridged in galvanized steel/aluminium thickness mm with 5 microns of primer and 20 microns of paint Coeff. of thermal transmission: K = type of xing W/m2 K kcal/m2 h C ; screw type and shank ; qty prevarnished on the visible side series prevarnished out of ridge

made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10%

43

ISOTAP 1000

(for Spain only)


Panel especialmente diseado para su uso en cubier tas inclinadas. Caracterizado por su sistema de junta y fijacin oculta, permite una superior simetra y efecto esttico del recubrimiento conjugando tales caractersticas con una larga durabilidad. La posibilidad de su utilizacin sobre cubiertas o fachadas simplifica la proyeccin y aprovisionamiento de los materiales.

1000 500 50 11 10 36 espesor 50 22 50 15

NOTAS PARA LA CONSULTA DE LA FICHA TCNICA

(la norma a la que se hace referencia y no se indica es la norma AIPPEG 1)

SOPORTE METLICO - Laminado de acero zincado Sendzimir (UNI EN 10326-UNI EN 10327) - Laminado de acero zincado prelacado con procedimiento Coil Coating - Laminado de aleacin de aluminio con acabado natural, gofrado o prelacado (EN 485-4) - Prelacado con proceso en continuo, con espesor en la cara vista de 5 micras de imprimacin y 20 micras de laca, en los siguientes acabados: polister, polister siliconado, PVDF (bajo pedido se puede fabricar acabado especial de alto poder anticorrosivo) - Laminado de cobre (DIN 1787 / 17670 / 1791) NCLEO AISLANTE Alma de espuma expandida, rgida y de alto poder aislante a base de resinas de poliuretano (PUR) autoextinguible *, satisfaciendo la norma UNE 41950, con los siguientes standard de calidad: - conductibilidad trmica A 10C: m = 0,020 W/mK - densidad total: 40 kg/m3 10% - adhesin al soporte: 0,10 N/ mm2 (mnimo) - compresin al 10% de deformacin: 0,11 N / mm2 (mnimo) - reaccin al fuego, para el panel completo: clase M2 (segn UNE 23727) AISLANTE TRMICO El coeciente de transmisin trmica K reejado en la cha tcnica debe considerarse til a 10C; el clculo tiene en cuenta la resistencia de las dos chapas metlicas, y la conductibilidad trmica til del clculo a 10C (atenuada

aplicando a m la bonicacin m = 10%): = 0,022 W /mK. CARGAS - Deformacin: admite una echa igual o menor a 1 / 200 L - Flexin se ha supuesto que el esfuerzo a la exin sea completamente absorbido por la chapa soporte - Corte: se presupone que el esfuerzo de corte sea absorbido en parte por la chapa soporte y en parte por la aislante Los datos reejados son meramente indicativos y reejados de buena voluntad. Es labor del proyectista tener en cuenta las especicaciones propias de cada obra. INSTRUCCIONES PARA LA FIJACIN El proyectista deber examinar las condiciones de empleo segn la situacin climtica local. Precauciones particulares se debern adoptar para la jacin de los paneles con soporte en aluminio, cobre o acero de color oscuro. Para ms informaciones, consultar las RECOMENDACIONES PARA EL MONTAJE DE CHAPAS PERFILADAS Y DE PANELES METLICOS AISLANTES emitidas por AIPPEG y el MANUAL DE MONTAJE Y FIJACIN emitido por Isopan spa.
*Isopan, bajo pedido, puede fabricar resinas de poliuretano que superen los ms severos test de reaccin al fuego para obtener paneles de clase M1 segn la norma P 92 501 (Francia ) o de clase B2 segn la norma DIN 4102 (Alemania). 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Asociacin Italiana de Productores de Paneles y Elementos de Grecas.

INSTRUCCIONES DE FIJACIN
EMPLEO EN CUBIERTAS Tornillo con arandela Tipo de jacin: Tipo y long del tornillo: - Auto-roscante 6,00 mm. Para espesor de correa 3 mm - Auto-taladrante 6,3 mm. Con falsa arandela incorporada Longitud: espesor nominal del Panel + 50 a 60 mm Cantidad: Encuentro de la greca del encaje con las correas / vigas EMPLEO EN FACHADAS Tornillo con arandela (*) - Auto-roscante 6,0 mm. Para espesor de correa 3 mm - Auto-taladrante 6,3 mm. Para espesor de correa < 3 mm Con falsa arandela incorporada Longitud: espesor nominal del panel + 50 a 60 mm Encuentro de la greca del encaje con las correas / vigas

(*) Para paneles con soportes de cobre pedir instrucciones especcas.

44

SOBRECARGA ENTRE-EJES
CHAPA DE ACERO DE ESPESOR 0,5 mm CARGA UNIFORMEMENTE DISTRIBUIDA
kg/m2 80 120 150 200 250 daN/m2 78 117 147 196 245 310 265 240 215 185 30 40 360 310 280 250 230 ESPESOR PANEL mm 50 405 350 320 285 250 60 450 390 355 320 285 80 540 465 425 380 340 30 360 310 285 255 225 DISTANCIA ENTRE EJES MAX cm ESPESOR PANEL mm 40 415 360 330 295 265 50 470 405 375 335 300 60 520 450 415 375 335 80 620 535 495 445 400 DISTANCIA ENTRE EJES MAX cm

CHAPA DE ACERO DE ESPESOR 0,5 / 0,4 mm CARGA UNIFORMEMENTE DISTRIBUIDA


kg/m2 80 120 150 200 250 daN/m2 78 117 147 196 245 300 255 235 205 175 30 40 345 295 270 240 220 ESPESOR PANEL mm 50 390 335 310 275 240 60 435 375 345 305 270 80 515 445 410 365 325 30 350 300 275 245 215 DISTANCIA ENTRE EJES MAX cm ESPESOR PANEL mm 40 400 345 320 285 255 50 450 390 360 325 290 60 500 435 400 360 320 80 595 515 475 425 380 DISTANCIA ENTRE EJES MAX cm

PESO DEL PANEL


PESO
30 kg/m2 10,30

ESPESOR NOMINAL PANEL mm


40 10,70 50 11,10 60 11,50 80 12,30

F F PREDISPOSICIN AL SOLAPE
K
30 W/m2 K kcal/m2 h C 0,58 0,51

AISLAMIENTO TRMICO
ESPESOR NOMINAL PANEL mm
40 0,46 0,40 50 0,38 0,33 60 0,32 0,28 80 0,25 0,22

TOLERANCIA DIMENSIONAL (segn la EN 14509)


COTAS EN mm
Longitud Ancho util Espesor Desviacin de la perpendicularidad No alineamiento de los paramentos metlicos interno L3m L>3m Solape izquierdo
D

5 mm 10 mm

Solape derecho

2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm

D = mm 100-150-200-250 Otras medidas segn acuerdos

Donde L es la longitud y D es el espesor de los paneles.

ESQUEMA PARA MEMORIA


Espesor Nominal Ancho til Soporte externo Soporte interno Aislamiento Fijacin mm mm 1000 grecado (altura de la greca 36 mm, entre grecas 500 mm) en acero galvanizado/aluminio/cobre de espesor mm prelacado en el lado visto tipo con 5 micras de imprimacin y 20 micras de lacado color kcal / m2 h C ; tipo y longitud de tornillo ; cantidad color microgrecado en acero galvanizado/aluminio de espesor mm con 5 micras de imprimacin y 20 micras de lacado Coef. de transm. trmica K = Tipo de jacin W / m2 K prelacado en el lado visto tipo + altura de la greca

en espuma rgida de alto poder aislante a base de resinas de poliuretano, densidad total kg/m3 40 10%

45

ISOGRECATA 1000
A panel designed for pitched covering surfaces. Characterized by its high economic benefits, it has an internal surface in embossed centesimal aluminium, while the external steel surface has the same nish as the Isocop-5 1000 nish.

1000 250 25 40
thickness

25

22

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). Due to thickness of aluminium foil, Isopan gives no guarantee for optical defects of the internal side. INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable *, with the following standards of quality: - thermal conducibility at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0.10 N/mm2 - value of compression at 10% of deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card should be considered useful for projects, at 10C; calculations have taken

into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK. WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established - Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.
* Upon request, Isopan can supply polyurethane resins suitable to pass the most severe re reaction tests, to obtain panels of class M1 according to the French norm P 92-501, B1 or B2 according to the German norm DIN 4102. 1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIRE REACTION Panels ISOGRECATA1000 eld-tested have obtained the following results: D-S3-D0 for 30-40-50-60 mm thick panels (in accordance with EN 13501-1).

46

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: FOR USE IN ROOFING PVC screw-washer - cap - gasket - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 6070 mm One for each ridge for extreme supports or heading overlaps One every two ridges for intermediate supports FOR USE IN WALLING PVC screw-washer (*) - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with false washer incorporated length: nominal thickness of panel + 2030 mm One for each ridge for extreme supports or heading overlaps One every two ridges for intermediate supports

Quantity:

(*) In the case of strong depression a 50 mm diam. washer should be interposed. For panels with aluminium or copper supports request special instructions.

OVERLOADS - SPANS
SHEET STEEL EVENLY DISTRIBUTED LOAD
kg/m 80 100 120 140 160
2

THICKNESS STEEL mm 0.5 0.6 235 220* 200* 185* 170* 0.7 MAX. SPAN cm 220* 200* 180* 165* 155* 250 235 215* 200* 185* 265 245 230 215* 200* 285 265 250 235 225 250* 220* 200* 185* 175* 0.8 1.0 0.5
2

THICKNESS STEEL mm 0.6 270 245* 225* 205* 195* 0.7 MAX. SPAN cm 285 260 240* 225* 210* 295 275 260 240* 225* 320 295 280 265 255 0,8 1.0

daN/m 78 98 117 137 156

SHEET ALUMINIUM EVENLY DISTRIBUTED LOAD


kg/m 80 100 120 140 160 * Rates with strain limitations.
2

THICKNESS STEEL mm 0.6 160* 140* 130* 120* 110* 0,7 170 155* 140* 130* 120* 0.8 180 165 155 140* 130* 1.0 190 180 170 160 150 0.6 180* 160* 145* 135* 125* MAX. SPAN cm

THICKNESS STEEL mm 0.7 190 175* 160* 150* 140* 0.8 200 190 185 160* 150* 1.0 220 205 190 180 170 MAX. SPAN cm

WEIGHTS OF PANELS
WEIGHT
kg/m2

NOMINAL THICKNESS OF PANEL mm


30 6.50 40 6.90 50 7.30 60 7.70

DIMENSIONAL TOLERANCES THERMAL INSULATION


K
W/m2 K kcal/m2 h C

DEVIATIONS mm
Length Effective width Thickness Orthometry and rectangularity 10 5 2 3 40 0.44 0.38 50 0.36 0.32 60 0.31 0.27

NOMINAL THICKNESS OF PANEL mm


30 0.55 0.48

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 ridged (ridge height mm 40, span mm 250) in galvanized steel thickness mm series with 5 microns of primer and 20 microns of paint natural, lacquered and embossed centesimal aluminium made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10% W/m2 K kcal/m2 h C ; screw type and shank ; qty type of xing prevarnished on the visible side colour out of ridge

Coeff. of thermal transmission: K =

47

ISODECK 40 1000
A panel designed for waterproof roong on at or pitched roof structures. This is a single sheet-steel panel, with its second surface made from bitumenised felt board. The waterproof roofing must be completed with a nal layer of bitumenised sheath.

thickness

40 25 1000 25 250 22

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Laminates of galvanized steel Sendzimir (UNI EN 10326-UNI EN 10327) - Laminates of galvanized steel, prevarnished with a Coil Coating procedure - Laminates of aluminium alloy, with a natural finish, embossed and prevarnished (EN 485) - Prevarnishing carried out by means of a continual-cycle process, with a thickness of the visible side of 5 microns of primer and 20 microns of paint, as follows: PS-PX-PVDF (special products with a high level of anticorrosion are available upon request). - Laminates of copper (DIN 1787/17670/1791). INSULATING MASS Rigid plastic with a high level of insulating power, made from polyurethane resins (PUR) and poliisocianurates (PIR) both self-extinguishable, with the following standards of quality: - thermal conducibility at 10C: m = 0.020 W/mK - total density: 40 kg/m3 10% - value of adhesion to supports: 0.10 N/mm2 - value of compression at 10% of deformation: 0.11 N/mm2. THERMAL INSULATION The coefcients of thermal transmission K mentioned in the data card

should be considered useful for projects, at 10C; calculations have taken into consideration the two external and internal laminate resistances and the thermal conductivity at 10C (obtained by applying the oversize m = 10% to m): = 0.022 W/mK. WEIGHT CAPACITY - Deformation: an indicator, similar to or below 1/200 L is established - Flexion: it is believed that the pressure of exion is entirely absorbed by the supporting steel - Kerf: it is believed that the pressure of the cut is partly absorbed by the supporting steel and in part by the resin. Information indicated in tables 1 and 2 is to be considered indicative. The project manager should check this data according to the specic applications. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.

1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

48

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: FOR USE IN ROOFING screw - self-tapping diam. 6.0 mm for surface support 3 mm - self-threading diam. 6.3 mm for surface support < 3 mm with a false washer incorporated, length 2530 mm One for each ridge for extreme external supports or heading overlaps One for every two ridges for intermediate supports The longitudinal overlapping ridges should be xed together by means of rivets or screws, with a maximum distance of 75 cm.

Quantity:

OVERLOADS - SPANS
SHEET STEEL EVENLY DISTRIBUTED LOAD
kg/m2 60 80 100 120 140 160 180 200 daN/m2 58 78 98 117 137 156 176 196 245 220* 200* 180* 165* 155* 145* 140* 260 235 220* 200* 185* 170* 160* 155* 0,5 NOMINAL THICKNESS STEEL mm 0,6 0,7 MAX. SPAN cm 275 250 235 215* 200* 185* 175* 165* 290 265 245 230 215* 200* 190* 180* 315 285 265 250 235 225 215* 200* 275 250* 220* 200* 185* 175* 165* 155* 295 270 245* 225* 205* 195* 180* 170* 0,8 1,0 0,5 NOMINAL THICKNESS STEEL mm 0,6 0,7 MAX. SPAN cm 310 285 260 240* 225* 210* 200* 185* 325 295 275 260 240* 225* 210* 200* 350 320 295 280 265 255 240* 225* 0,8 1,0

* Rates with strain limitations.

WEIGHTS OF PANELS
WEIGHT
kg/m2

NOMINAL THICKNESS OF PANEL mm


30 6.90 40 7.30 50 7.70 60 8.10

THERMAL INSULATION
K
W/m2 K kcal/m2 h C

DIMENSIONAL TOLERANCES
DEVIATIONS mm
Length Effective width Thickness Orthometry and rectangularity 10 5 2 3 40 0.44 0.38 50 0.36 0.32 60 0.31 0.27

NOMINAL THICKNESS OF PANEL mm


30 0.55 0.48

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 asphaltic felt g/m2 500 ridged (height of ridge 40 mm, distance 250 mm) made from galvanized steel, thickness mm visible side series Coeff. of thermal transmission: K = type of xing W/m2 K with 5 microns of primer and 20 microns of paint kcal/m2 h C ; screw type and shank ; qty colour prevarnished on the out of ridge

made of rigid plastic with a high level of insulating power made from polyurethane resins, total density kg/m3 40 10%

49

ISORAY 3.3 ISORAY 6


ISORAY is a precurved thermoinsulated, roof panel. Two radiuses are available: 3.3 m and 6 m. It has been designed to cover at R.C. prefabricated structures, it is able to guarantee waterproofing, thermal insulation and it has either an excellent look on the lower surface. The five ribs shape adds a very high strength and excellent load resistance performaces.

Corrugated sheet made of pre-painted or mill nished Aluminium/Galvanised steel

Primer Polyurethane Primer

Ribbed self-extinguishing closing piece


1000 250 40 thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SURFACES - Sendzimir galvanised steel sheet (UNI EN 10326-UNI EN 10327). - Galvanised steel sheet, pre-painted by means of a Coil Coating process. - Aluminium alloy sheet, mill nish, stucco embossed or pre-painted (EN 485). - Continuous pre-painting process with a 5 m thick primer and a 20 m paint on the items visible side. Available in the following lines: PS-PX-PVDF (On request, ISOPAN can also supply very anticorrosive special products). - Copper sheet (DIN 1787/17670/1791). INSULATING LAYER High insulation-ability rigid polyurethane produced by a self-extinguishing resin, with the following quality standards: - thermal conductivity at 10C: m = 0.020 W/mK - total density: 42 kg/m3 10% - support adhesion value: 0.10 N/mm2 - compression value at 10% deformation: 0.11 N/mm2 THERMAL INSULATION The thermal transmission coefcients K specied in the product data sheet are to be considered as design specications at 10C; reckoning takes into account the two laminar resistances - external and internal - and useful thermal conductivity calculated at 10C (obtained by applying the increase factor m = 10% to m): = 0.022 W/mK.
1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

50

free spans

LOAD LIMITS (Kg/m2)


ISORAY 3.3 PANEL
With 0.5 mm thick galvanized steel sheet

STATIC DIAGRAM INSULATION THICKNESS mm


40 50 60

STATIC DIAGRAM INSULATION THICKNESS mm


40 50 60

With 0.6 mm thick aluminium external sheet and 0.5 mm thick galvanized steel internal sheet

ISORAY 3.3 PANEL

SPAN (m)
1 410 490 590 1.5 370 425 490 2 290 340 380 2.5 250 280 300 2.75 230 260 220 3 210 240 260

SPAN (m)
1 400 480 580 1.5 250 315 380 2 210 260 290 2.5 180 210 230 2.75 165 185 195 3 150 170 180

STATIC DIAGRAM INSULATION THICKNESS mm


40 50 60 80

ISORAY 6 PANEL
With 0.5 mm thick galvanized steel sheet

SPAN (m)
1 390 490 590 801 1.5 256 323 390 520 2 190 240 280 348 2.5 190 220 240 283 3 170 200 220 264 3.5 150 170 190 234 4 110 130 150 198 4.5 85 100 120 173 5 75 83 90 5.5 62 67 73 5.7 58 62 68 -

STATIC DIAGRAM INSULATION THICKNESS mm


40 50 60 80

ISORAY 6 PANEL
With 0.6 mm thick aluminium external sheet and 0.5 mm thick galvanized steel internal sheet

SPAN (m)
1 390 490 590 787 1.5 256 323 390 511 2 190 240 270 342 2.5 182 210 230 271 3 150 170 180 218 3.5 130 150 160 197 4 80 100 110 145 4.5 70 85 105 151 5 60 65 70 5.5 50 52 55 5.7 48 50 50 -

Note: the values shown in red indicate the admissible loads of the panel when anchored and xed to the support. The data indicated in tables are to be considered indicative. The project menager should check this data according to the specic applications.

PANEL THICKNESS mm
40 50 60 80

THERMAL TRANSMISSION COEFFICIENT K


Kcal/m2 hC Watt/m2 K

PANEL WEIGHT (Kg/m2) WITH 0.5 mm STEEL SHEET 10,25 10,65 11,05 11,85

DEVELOPMENT-SPAN-DEFLECTION

0,38 0,32 0,27 0,22

0,45 0,38 0,32 0,25

X Z Y
ISORAY 3.3 PANEL
SPAN
DEVELOPMENT DEFLECTION

FIXING

ISORAY 6 PANEL
SPAN Y (cm) 150 200 250 300 350 400 450 500 550 558
DEVELOPMENT DEFLECTION

Support type A
Self-threading screws for xing panel on pre-shrunk reinforced concrete

Support type B
Self-threading screw or bolt

Y (cm) 107 137 158 177 196 216

X (cm) 120 151 173 194 214 235 257 278 284 300

Z (cm) 4 7 10 12 15 18 22 26 27 30

X (cm) 162 214 265 317 370 423 477 533 589 598

Z (cm) 5 8 13 19 26 34 44 55 67 69

Bituminous sealant 30/10 press bent for panel support

236
M14 dowel every 50 cm

255 260 275

The measures are related to a panel of 40 mm thickness. Kindly contact Isopan for any further queries regarding the laying and xing system.
Span

DIMENSIONAL TOLERANCES
DEVIATIONS mm
Lenght of the development Width Thickness Span Radius of curvature Internal sheets closing 5 mm if L 3000 / 10 mm if L > 3000 2 2 3% 2% F=0+3

Curved panel

Prefabricated reinforced concrete beam

R=3300/6000
Free span

51

ISOFIRE ROOF 1000


This panel is designed for sloped roof use. Its mineral fibre core guarantees incombustibility, as well as assuring an excellent thermal insulation. ISOFIRE ROOF 1000 was designed to meet the growing requirements in terms of re behaviour, guaranteeing at the same time high mechanical performances.

1000 250 40 25

thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SURFACES - Sendzimir galvanised steel sheet (UNI EN 10326-UNI EN 10327). - Galvanised steel sheet, pre-painted by means of a Coil Coating process. - Aluminium alloy sheet, mill nish, stucco embossed or pre-painted (EN 485). - Continuous pre-painting process with a 5 m thick primer and a 20 m paint on the items visible side. Available in the following lines: PS-PX-PVDF (On request, ISOPAN can also supply very anticorrosive special products). INSULATING LAYER Insulating layer made of high-density mineral bres (100 kg/m3, m = 0.040 W/mK at 10C). LOAD LIMITS - Deformation: a deection equal to or lower than 1/200 L of the free span is admitted. - Deection: it is assumed that the bending stress is completely absorbed by the steel support sheets.

- Cut: it has been assumed that the cutting stress is absorbed partly by the steel support sheets and partly by the insulation material. The data specied in tables 1 and 2 are to be considered as indicative. The designer will have to verify and adjust such details with regard to every specic application. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. The maximum recommended length for correctly handling mineral bre panels is 6000 mm.

1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: ROOF APPLICATION PVC screw-washer (*) self-tapping, 6.0 mm for 3 mm thick supports; self-threading, 6.3 mm for < 3 mm thick supports, with an incorporated drive washer; length: panel nominal thickness + 60 70 mm One for each rib (terminal or overlapping supports); one every two ribs (intermediate supports)

Quantity:

(*) In the event of a considerable structural low, it is advisable to interpose a 50 mm washer. For panels with aluminium or copper supports, please require ISOPANs special instructions.

On request, ISOPAN can issue the following re behaviour certications: FIRE REACTION Panels ISOFIRE ROOF 1000 eld-tested in accordance with the Ministerial Decree dated 26th June 1984, have been granted the re reaction category 0-0. FIRE RESISTANCE Panels ISOFIRE ROOF 1000 eld-tested have obtained the following results: REI level 30 for 50 mm thick panels (circular letter n.91 dated 14th September 1961) REI level 60 for 80 mm thick panels (circular letter n.91 dated 14th September 1961) REI level 120 for 100 mm thick panels (circular letter n.91 dated 14th September 1961) REI level 180 for 150 mm thick panels (circular letter n.91 dated 14th September 1961) REI level 60 for 80 mm thick panels (in accordance with EN 13501-2) REI level 120 for 100 mm thick panels (in accordance with EN 13501-2)

52

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 80 100 120 150 200 daN/m2 78 98 117 147 196 330 305 270 220 165 420 390 400 335 255 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 460 435 415 390 310 500 470 450 420 365 535 500 480 450 420 365 330 290 240 175 465 415 395 325 275 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 510 455 405 350 285 550 480 435 365 290 575 505 440 365 305 120 150

SHEET STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m2 80 100 120 150 200 daN/m2 78 98 117 147 196 350 325 290 235 180 450 420 400 355 275 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 495 465 445 415 340 535 505 480 450 400 570 540 515 480 460 390 355 315 260 195 500 450 400 350 300 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 550 490 440 380 320 590 520 470 400 330 615 550 480 400 350 120 150

WEIGHTS OF PANELS
STEEL WEIGHT THICKNESS
0,5 0,6 kg/m2 kg/m2

NOMINAL THICKNESS OF PANEL mm


50 13,5 15,50 80 16,4 18,30 100 18,5 20,20 120 20,4 22,30 150 23,2 25,30

F F
Isore Roof panel assembly system

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
During mounting phase make lateral pressure to ensure appropriate closing of the panels

Length Effective width Thickness Deviation from perpendicularity Misalignment of internal metal facing Internal sheets closing

L3m L>3m 2 mm

5 mm 10 mm

THERMAL INSULATION
K
W/m2 K kcal/m2 h C

D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm

NOMINAL THICKNESS OF PANEL mm


50 0,72 0,64 80 0,44 0,38 100 0,36 0,32 120 0,3 0,26 150 0,25 0,22

Where L is the length and D is the thickness of the panels.

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 ribbed (40 mm high ribs, 250 mm axle spacing), in galvanised steel/aluminium, thickness mm visible side: line , with 5 microns of primer and 20 microns of painting , colour kcal/m2 h C ; type of screw ; quantity , colour microribbed, in galvanised steel/aluminium, thickness mm with 5 microns of primer and 20 microns of painting carried out by high-density mineral bres (100 kg/m3) W/m2, K type of xing device Coeff. of thermal transmission: K = , prepainted visible side: line , prepainted

53

ISOFIRE ROOF - FONO


The range of FONO panels was designed to satisfy the increasing demands for performance in sandwich panels in terms of soundproong, guaranteeing the non-combustibility of the product at all times. The ISOFIRE ROOF FONO panel is designed for use in sloped roong.

1000 250 40 25

thickness

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Sendzimir galvanised steel sheet (UNI EN 10326-UNI EN 10327). - Galvanised steel sheet, pre-painted by means of a Coil Coating process. - Aluminium alloy sheet, mill nish, stucco embossed or pre-painted (EN 485). - Continuous pre-painting process with a 5 m thick primer and a 20 m paint on the items visible side. Available in the following lines: PS-PX-PVDF (On request, ISOPAN can also supply very anticorrosive special products). INSULATING LAYER Insulating layer made of high-density mineral bre (100 kg/m3, m = 0.040 W/mK at 10C). LOAD LIMITS - Deformation: a deection equal to or lower than 1/200 L of the free span is admitted.

- Deection: it is assumed that the bending stress is completely absorbed by the steel support sheets. - Cut: it has been assumed that the cutting stress is absorbed partly by the steel support sheets and partly by the insulation material. The data specied in tables 1 and 2 are to be considered as indicative. The designer will have to verify and adjust such details with regard to every specic application. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.

1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: USE OF ISOFIRE ROOF - FONO screw-PVC washer (*) self-tapping, 6.0 mm for 3 mm thick supports; self-threading, 6.3 mm for < 3 mm thick supports, with false incorporated washer; length: panel nominal thickness + 60 70 mm One for each rib (terminal or overlapping supports); one every two ribs (intermediate supports)

Quantity:

(*) in the case of strong depression the use of a 50 mm washer is recommended. For panels with aluminium or copper supports, please ask for specic instructions.

54

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD
kg/m2 80 100 120 150 200 daN/m2 78 98 117 147 196 240 235 225 188 165 350 310 290 270 230 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 380 365 345 305 275 395 390 365 320 290 404 400 380 325 305 325 315 305 260 195 390 375 365 348 298 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 435 405 385 375 315 470 420 410 391 321 500 435 420 398 348 120 150

WEIGHTS OF PANELS F
STEEL WEIGHT THICKNESS
0,6 kg/m2

NOMINAL THICKNESS OF PANEL mm


50 13,82 80 16,62 100 18,52 120 20,62 150 23,62

F
Isore Roof Fono panel assembly system

During mounting phase make lateral pressure to ensure appropriate closing of the panels

THERMAL INSULATION
K
W/m2 K kcal/m h C
2

DIMENSIONAL TOLERANCES (in compliance with EN 14509)


DEVIATIONS mm
Length Effective width Thickness L3m L>3m 2 mm D 100 mm 2 mm D > 100 mm 2 % 6 mm 3 mm F = 0 + 3 mm 5 mm 10 mm 100 0,36 0,32 120 0,3 0,26 150 0,25 0,22

NOMINAL THICKNESS OF PANEL mm


50 0,72 0,64 80 0,44 0,38

On request ISOPAN can issue the following certications concerning noise behaviour: SOUND INSULATION Rw = 30 dB; Rw = 32 dB - (Roof fono, 50 and 80 thick) NOISE ABSORPTION Weighted sound absorption coefcient w = 1

Deviation from perpendicularity Misalignment of internal metal facing Internal sheets closing

Where L is the length and D is the thickness of the panels.

FIRE RESISTANCE Panels ISOFIRE ROOF FONO 1000 eld-tested have obtained the following results: REI 60 for 80 mm thick panels (in accordance with EN 13501-2)

55

56

Corrugated sheets

57

LG 50/1000
Sheet proled and contoured in a tile pattern, a major aesthetic development in roong sheets intended mainly for public buildings. The architectural design in the form of tiles makes it possible to achieve a functional which has a high aesthetic value, combined with lightness, extreme simplicity of installation, and impermeability.

Also available with anti-condensation felt (*)

A B C B C B A
Minimum pitch 11%

Fixing screws position C

Fixing screws position B

Fixing screws position A

Proled sheet 50

33

200

200

200 1000

200

200

37

58

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SUPPORTS - Rolled steel sheets galvanised by the Sendzimir process (UNI EN 10326-UNI EN 10327) - Rolled steel sheets galvanised and prepainted by the Coil Coating process - Rolled sheets in aluminium alloy, with natural nish, embossed and prepainted (EN 485) - Prepainting carried out by continuous process, with thickness on the visible side of 5 microns of primer and 20 microns of paint, in the following series: PSPX-PVDF (special products can be supplied on request, with extremely high anti-corrosion properties). - Rolled copper sheets (DIN 1787/17670/1791) - Nominated supplier: Magona DItalia (Gruppo Arcelor) - Hot-dip galvanised rolled steel sheets (HDG). Crack resistance (Z-200) complying with EN 10147 - Rolled steel sections galvanised and prepainted by the Coil Coating process - Certied steel, as attested by Test Certicates as per EN 10204 3.1.B - Steel quality standard: S 250 GD DM 9-1-96 - Prepainting performed by continuous process, with thickness of 25 m - Painting cycle resistant to discolouration and chalking - Resistance to ageing during outdoor exposure: 10 years (EN 1352319) - Cladding resistant to humidistat (ISO 6270-1) - Cladding resistant to saline mist (EN 13523-8) - Fire resistance: Class 0 (DM 14-01-85) - Category for protection against corrosion: CP5 (EN 10169-2) - UV resistance category: Ruv2 (EN 10169) - Rolled sheets in aluminium alloy on request, with natural nish, embossed and prepainted (EN 485) - Rolled sections in copper on request (DIN 1787/17670/1791) INSTRUCTIONS FOR FIXING The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa. PUTTING INTO SERVICE, MAINTENANCE AND INSPECTION - Reference standard: UNI 10372, with the following notes: - Minimum recommended pitch is 11%, to allow drainage of rainwater and any deposits caused by moisture. - For maximum product durability, we recommend inspecting the roof periodically and removing any material or sediment deposited which could cause water to collect.
1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

(*) The sheets can be supplied backed with anti-condensation material, with the following chief specications.
Adhesive non-woven polyester felt (on request only).
Colour Thickness - felt Water absorption Reaction to re DIN 4102/1 125 Hz 500 Hz Sound absorption DIN EN 20354 1000 Hz 2000 Hz 4000 Hz Thermal conductivity DIN 52612 W/mK DIN EN ISO 9073 - 2 white-grey mm g/m2 1 > 900 B1 reduction by 2% reduction by 4% reduction by 4% reduction by 1,2% reduction by 4,2% 0,045

STANDARD LENGTHS
STANDARD LENGTHS OF SHEETS
mm 1200 2250 2950 4000 4700 5050 5750 6100 6450

maximum possible distance between centres 350 mm


every 2 001050 3 cours es
xing screws

DIMENSIONAL TOLERANCES
DEVIATIONS mm
Length Useful width 10 5

DRAFT OF SPECIFICATIONS
Useful width Appearance 1000 mm wavy, like tiles (height of corrugation: 50 mm, distance between centres 200 mm) in galvanised steel/aluminium/copper, thickness mm prepainting on visible side series paint Fixings type of xing colour ; type of screw ; quantity with 5 microns of primer and 20 microns of

59

20/28 SHEETS
VENTI roofing system
The Venti system is particularly manageable and easy to install. It includes straight and curved sheets. In the aluminium version it has the feature of being able to be curved on site, depending on the thickness.

Venti 16
CHARACTERISTICS OF THE SECTION
THICKNESS mm
0,5 Weight (steel) J W (kg/m2 gross)
2

g Drainage channel
0,8 7,83 2,71 6,24 6,00

0,6 5,87 2,03 4,57 4,45

0,7 6,85 2,37 5,41 5,23

4,89 1,69 3,74 3,66

Example of overlap mple

Weight (aluminium)(kg/m gross) (cm4/m) (cm /m)


3

Venti 14
DIMENSIONAL TOLERANCES
Length: +10 mm up to 3000 mm +20 mm over 3000 mm -5 mm for all lengths Useful width: Out-of-square: 5 mm S 0.5% of the useful width

Drainage channel

Example of overlap e

Overall width 21,8 23 23 20 52,12

1205 mm 75 SIDE A

SIDE B Useful width/spacing 1125 mm

Venti 16
Overall width 23,6 21,8 23 23 20 SIDE B Useful width/spacing 975 mm 52,12 1055 mm 75 SIDE A

Venti 14

MAXIMUM UNIFORMLY DISTRIBUTED LOAD IN kg/m2 LG 20


THICKNESS mm 1,00 0,5 0,6 0,7 0,8 430 530 630 700 1,25 220 270 320 370 STEEL - SPACING m 1,50 128 155 185 215 1,75 80 100 115 135 2,00 54 65 78 90 2,25 38 45 55 62 2,50 28 34 40 45 1,00 138 168 200 230 1,25 70 86 102 118 ALUMINIUM - SPACING m 1,50 41 50 58 68 1,75 26 31 37 43 2,00 17 21 25 29 2,25 12 15 17 20

60

VENTOTTO roofing system


For a very long time, this has been the most used profile, because it can be used to make roofs with wide spacing between the supports, even in areas of high rainfall and snowfall, if they are properly designed.

Ventotto 11
CHARACTERISTICS OF THE SECTION
THICKNESS mm
0,5 Weight (steel) J W (kg/m2 gross) (cm /m)
4

Drainage channel
0,8 7,64 2,65 9,94 6,76

0,6 5,73 1,98 7,29 4,99

0,7 6,68 2,32 8,62 5,88

4,77 1,65 5,96 4,10

Example of overlap ample

Weight (aluminium)(kg/m2 gross) (cm3/m)

Ventotto 9
DIMENSIONAL TOLERANCES
Length: +10 mm up to 3000 mm +20 mm over 3000 mm -5 mm for all lengths Useful width: Out-of-square: 5 mm S 0.5% of the useful width

Drainage channel Example of overlap

Overall width 34,8 36 36 36 27,1 76,11 112

1235 mm SIDE A

SIDE B Useful width/spacing 1120 mm

Ventotto 11

Overall width 34,8 36 36 27,1 76,11

1012 mm 112 SIDE A

SIDE B Useful width/spacing 896 mm

Ventotto 9

MAXIMUM UNIFORMLY DISTRIBUTED LOAD IN kg/m2 LG 28


THICKNESS mm 1,00 0,5 0,6 0,7 0,8 690 820 1000 1110 1,25 350 430 510 580 STEEL - SPACING m 1,50 205 250 290 340 1,75 128 155 185 215 2,00 85 105 125 145 2,25 60 74 88 100 2,50 44 53 63 75 1,00 220 268 315 365 1,25 112 138 160 185 ALUMINIUM - SPACING m 1,50 65 80 94 108 1,75 41 50 60 68 2,00 28 34 40 46 2,25 19 24 28 32

61

20/28 SHEETS

Technical Data
STRAIGHT RIBBED SHEETS It is possible to make ribbed sheets in Venti and Ventotto profiles. Characteristic data: minimum workable thickness: maximum workable thickness: maximum workable length: minimum workable length: 0,5 mm; 0,8 mm; 14.000 mm; 1.000 mm.

CURVED SHEETS

It is possible to curve sheets with profiles with a notching system. Characteristic data: minimum length of sheet: minimum radius of curvature maximum length of sheet:

Venti and Ventotto

1.000 mm; 700 mm; 6.000 mm.

For sheets with dimensions different from those indicated, it is advisable to contact the Isopan technical office to assess feasibility. NOTCHED SHEETS It is possible to notch sheets with Venti and Ventotto profiles with customised designs. Characteristic data: minimum length of sheet: 1.000 mm; maximum length of sheet: 6.000 mm. For sheets with dimensions different from those indicated, or very complex configurations (with more than one curve and different angles) it is advisable to contact the Isopan technical office to assess feasibility.
USE FOR RIDGE
Length mm

SYMMETRICAL ROOF/ WALL JOINT PANEL

ASYMMETRICAL ROOF/ WALL JOINT PANEL

NOT FEASIBLE
Radius of curvature mm

HINGE-TYPE RIDGE, STAMPED

STAMPED FLASHING

CURVED SHEET

SPECIAL CURVED SHEET, PARTLY NOTCHED


230 230

62

NOT FEASIBLE

LG 38/915 - 732
NOTES FOR CONSULTATION OF THE DATA CARD
(reference should be made to norm AIPPEG
1

for anything not mentioned herein)

METAL SUPPORTS - Rolled steel sections galvanised by the Sendzimir process (UNI EN 10326-UNI EN 10327) - Rolled steel sections galvanised and prepainted by the Coil Coating process - Rolled sections in aluminium alloy, with natural nish, embossed and prepainted (EN 485) - Prepainting carried out by continuous process, with thickness on the visible side of 5 m of primer and 20 m of paint - Rolled sections in copper (DIN 1787/17670/1791). LOADING - Deformation: if not otherwise specied, a maximum curvature of 1/200 L is permissible. INSTRUCTIONS FOR FIXING The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.
1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

NOTES ON THE CHARACTERISTICS OF THE SECTION


THICKNESS mm
0,5 Weight (kg/m2) J W (cm4/m) (cm3/m) 5,28 10,3 3,53 0,6 6,42 13,7 4,71 0,7 7,49 16,0 5,51 0,8 8,57 18,3 6,32 1,0 10,72 22,8 7,94 Useful width: Out-of-square: Length:

DIMENSIONAL TOLERANCES
+10 mm up to 3000 mm +20 mm over 3000 mm -5 mm for all lengths 5 mm S 0,5% of the useful width

915 732 15 38 SIDE A SIDE B 28 183

MAXIMUM UNIFORMLY DISTRIBUTED LOAD IN kg/m2 Ribbed Sheet LG 38/915 - 732 THICKNESS mm
0,5 0,6 0,7 0,8 1,0 SPACING m 1,00 305 520 610 700 880 1,25 200 330 390 445 560 1,50 140 230 270 305 385 1,75 100 170 195 225 280 2,00 75 125 150 170 210 2,25 55 90 100 105 115 120 130 150 165 75 125 145 165 210 2,50 45 65 80 75 90 85 105 110 130 60 100 115 135 170 60 55 75 60 85 80 110 50 80 95 110 135 70 60 90 40 60 65 70 80 80 90 100 110 55 65 65 75 80 95 50 65 60 80 75 60 50 2,75 40 3,00 3,25 3,5

0,5 0,6 0,7 0,8 1,0

390 650 765 875 1100

250 415 490 560 700

180 285 335 385 485

150 210 245 280 350

100 160 185 215 270

The values in red do not allow for limits of deection.

63

LG 40/1000 - LG 40R/1000
NOTES FOR CONSULTATION OF THE DATA CARD
(reference should be made to norm AIPPEG
1

for anything not mentioned herein)

METAL SURFACES - Sendzimir galvanised steel sheet (UNI EN 10326-UNI EN 10327). - Galvanised steel sheet, pre-painted by means of a Coil Coating process. - Aluminium alloy sheet, mill nish, stucco embossed or pre-painted (EN 485). - Continuous pre-painting process with a 5 m thick primer and a 20 m paint on the items visible side. - Copper sheet (DIN 1787/17670/1791). LOAD LIMITS - Deformation: a deection equal to or lower than 1/200 L of the free span is admitted. FIXING INSTRUCTIONS The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.
1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

SECTION TECHNICAL SPECIFICATIONS


THICKNESS mm
0.5 Weight (kg/m2) J W (cm4/m) (cm3/m) 4.9 12.3 3.92 0.6 5.89 16.05 5.30 0.7 6.87 18.72 6.18 0.8 7.85 21.40 7.07 1.0 9.81 26.75 8.83
1000 55 40 SIDE A 25

DIMENSIONAL TOLERANCES
Length: +10 mm up to 3000 mm +20 mm over 3000 mm -5 mm for all lenghts Net width: Out-of-squareness: 5 mm S 0.5% of net width

LG 40/1000

250

LG 40R/1000
40

SIDE A

SIDE B SIDE B 55 25 1000 250

UNIFORMLY DISTRIBUTED MAXIMUM LOAD kg/m2


LG 40/1000 THICKNESS mm
0.5 0.6 0.7 0.8 1.0 MAX SPAN (m)
1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.5 3.75 439 281 185 143 109 86 115 121 135 141 154 162 193 202 111 63 70 84 98 98 114 112 131 140 163 90 47 58 63 81 73 94 84 108 105 135 67 73 101 36 48 48 68 57 79 65 91 81 113 51 62 81 85 95 99 108 113 135 142 38 58 67 44 51 77 64 97 40 53 64 72 74 84 85 97 106 51 62 59 73 68 83 85 48 63 55 72 69 45 64 57 80 35 58 41 67 51 83 33 58 41 72 34 64 4 1.00 360 104 84

LG 40R/1000
MAX SPAN (m)
1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.5 3.75 230 152 59 74 68 99 84 119 100 138 136 178 83 91 113 124 140 148 168 173 223 37 57 49 80 61 96 73 112 99 27 47 37 66 46 79 55 92 74 35 66 42 78 57 33 65 45 85 27 56 36 73 29 64 24 56 4

117 109 145 97

614 393

273

200

153

504

322

224

164 126 178 119 196 150 214 143 229 175 289 194 295 225

716 458

318

234

179

603

386

268

820 524

364

267

205

701

449

311

1024 655

455

334

256

903

578

401

144 119 100 61 73 83 100 102 120 122 41 60 62 83 76 99 92 30 51 48 70 59 83 71 97 95

0.5 0.6 0.7 0.8 1.0

570 365

252

180

141

467

300

207 147 115

768 491

341

251

192

152

123

630

403

280 205 157

896 573

398

292

224

177

143

118

754

482

335 246 188

46 71 55 83 75

37 61 44 71 60 92 36 62 49 80 40 70

1025 656

455

334

256

202

164

135

877

561

389 286 219

140 116 165 124

1280 819

569

418

320

253

204

169

121 104 91

1129

722

502 368 282

180 149 125 106

Values in red do not envisage limit conditions as far as the deection is concerned.

64

LG 55/600 - 750
NOTES FOR CONSULTATION OF THE DATA CARD
(reference should be made to norm AIPPEG
1

for anything not mentioned herein)

METAL SUPPORTS - Rolled steel sections galvanised by the Sendzimir process (UNI EN 10326-UNI EN 10327) - Rolled steel sections galvanised and prepainted by the Coil Coating process - Rolled sections in aluminium alloy, with natural nish and/or prepainted (EN 485) - Prepainting carried out by continuous process, with thickness on the visible side of 5 m of primer and 20 m of paint - Rolled sections in copper (DIN 1787/17670/1791). LOADING - Deformation: if not otherwise specied, a maximum curvature of 1/200 L is permissible. INSTRUCTIONS FOR FIXING The project manager should evaluate the conditions of use according to the local climatic situation. Particular attention should be paid to the xing of panels with aluminium, copper supports or dark colour painted steel. For further information, please consult RECOMMENDATIONS FOR THE FIXING OF STEEL PANELS AND OF INSULATED METAL PANELS issued by AIPPEG and the MANUALE DI POSA E FISSAGGI drawn up by Isopan Spa.
1- AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

NOTES ON THE CHARACTERISTICS OF THE SECTION


THICKNESS mm
0,6 Weight (kg/m2) J W (cm4/m) (cm3/m) 7,8 38,8 11,3 0,7 9,1 47,2 13,9 0,8 10,5 55,8 16,8 1,0 13,1 73,7 23 1,25 16,3 96,3 31,3
750 600 SIDE A 55 90 60 150

DIMENSIONAL TOLERANCES
Length: +10 mm up to 3000 mm +20 mm over 3000 mm -5 mm for all lengths Useful width: Out-of-square: 5 mm S 0,5% of the useful width

SIDE B

MAXIMUM UNIFORMLY DISTRIBUTED LOAD IN kg/m2 Ribbed Sheet LG 55/600 - 750 THICKNESS mm
0,6 0,7 0,8 1,0 1,25 SPACING m 1,00 1433 1,25 914 1,50 633 784 946 1,75 463 573 693 948 2,00 352 436 528 730 723 955 986 442 550 662 907 2,25 266 277 324 343 385 415 509 569 666 776 348 433 521 714 974 2,50 192 223 233 276 278 334 368 459 482 626 280 349 420 576 786 2,75 183 142 173 226 206 275 273 377 358 515 230 287 346 351 464 474 607 647 3,00 108 152 131 188 157 229 208 315 272 430 185 192 227 240 268 289 354 397 464 541 3,25 83 128 101 159 121 194 161 266 211 364 144 163 177 203 208 245 276 336 362 459 3,5 65 110 79 136 95 166 126 228 166 312 114 139 140 174 165 210 219 288 287 394 3,75 51 94 62 117 75 143 101 197 132 270 91 120 112 151 132 181 176 249 230 341 4 41 82 49 102 60 124 81 172 106 235 73 105 91 132 107 158 143 218 187 298 4,25 33 72 40 89 49 109 65 151 86 207 60 92 75 116 88 139 117 192 153 262 4,5 26 63 32 78 39 96 53 133 70 183 49 81 62 102 72 123 97 170 127 232 4,75 21 56 25 69 32 85 43 116 57 163 41 72 51 91 60 109 80 151 106 207 5 17 50 20 61 26 76 36 106 47 145 34 64 43 81 50 98 67 135 88 185

1776 1133 2142 1367

2929 1871 1295

3990 2548 1765 1293

0,6 0,7 0,8 1,0 1,25

1794 1145 2224 1420

793 984

580 721 868

2680 1711 1185

3685 2341 1622 1189

4991 3189 2210 1620 1237

The values in red do not allow for limits of deection.

65

COLOUR CHART

white range
white-grey white 9002 white 9010 pirineo white

RAL9002

SIMILRAL9010

cream range
ivory sand yellow

SIMILRAL1015

SIMILRAL1021

green range
olive green mint green navarra green reseda green moss green

SIMILRAL6003

SIMILRAL6029

SIMILRAL6011

SIMILRAL6005

red range
oxide red teja red firey red

SIMILRAL3009

SIMILRAL3000

brown range
dark brown

note

The most suitable covering must be chosen according to the environmental characteristics of where the sheet is to be installed (see back cover). A difference of colours can be noticed between different production batches and/or between the panels produced in different moments, especially for the colour RAL 9006, given the fact that it is a metallized colour.

SIMILRAL8014

66

grey range
silver metalic anthracite grey dark grey merlin grey goosewing grey

SIMILRAL9006

SIMILRAL7016

SIMILRAL7022

blue range
lake blue dark blue gentian blue

SIMILRAL5008

SIMILRAL5010

isodomus range
antique red antique grey antique green antiqued reale antico

special range
white-grey aluminium siena red aluminium
dark brown aluminium

natural aluminium

natural copper

SIMILRAL3009

SIMILRAL8014

natural stainless steel

top class white

covering
covering warranty
A written, formal warranty of durability of the covering can be supplied, providing that all the conditions (environmental, morphologic, climatic, correct installation, etc) specied in the warranty itself are respected. The durability of the covering also depends clearly on the type of covering chosen, as well as the nal destination of the material.

customised coverings
While not kept in stock, many other colours can be supplied. On request, we can also provide a master colour of any shade and/or paint that you may have chosen. The colour solutions are however bound by minimum production quantities (minimum acceptable batches).

product cleaning and maintenance


If the covering requires cleaning, the type of product used for cleaning and the application methods must be compatible with the chosen covering. The maintenance of pre-painted surfaces must respect the AIPPEG recommendations. The ISOPAN technical department is at the disposal of all customers for any consultation and queries.

Check the availability of the colours depending on the use and on the thickness of the metal supports.

67

COLOUR CHART
level of resistance of coverings
excellent

metal coverings

average

good

very good

cold rolled steel hot galvanising phosphating primer nishing paint

PS polyester

PX polyester

Plastisol

PVDF

PVC 100

The above graph shows the behaviour of the different coverings, when they are subjected to identical exposure conditions. This data is indicative only and is not in any way binding. Polyester PS: external covering, made of a primer and a coloured top coat, particularly suited to normal environments with low pollution levels. Polyester PX: external covering, made of a primer and a coloured top coat, particularly resistant to colour fading and pulverisation. Plastisol: external covering made of an anti-corrosion primer and a thick layer of highly protective paint, particularly suited for use in environments where aggressive chemical agents are present. PVDF: external covering made of a primer and a coloured top coat, particularly resistant to UV rays and chemical agents, even in aggressive environments. PVC: plastic covering, with high level of protection. Resistant to aggressive environments. For external use, please consult ISOPAN.
corrosion-resistant UV ray resistant natural ageing resistant

Primer or back coat phosphating hot galvanising

Laboratory tests carried out according to the test methods foreseen by the European Coil Coating Association (ECCA).

guide to the choice of covering


choice in relation to exposure
EXTERNAL
INDUSTRIAL AND URBAN TYPE RURAL NON POLLUTING NORMAL HARD SEA MIXED/ SPECIAL CLEAN/ DRY DAMP HOSTILE

INTERNAL

PS polyester PX silicon polyester

ideal covering

ideal choice to be agreed following consultation with the supplier

suitable covering

not ideal coating

special precautions
Care must be taken not to knock or scratch the covering or to deform the sheet edges and micro-grain. In the event of scratches, these can be touched up with paint. The xing holes and any cuts in length or width may produce chips that could stick to the covering, both due to their shape and the increase in temperature. Any chippings must therefore be removed as quickly as possible to stop them from rusting and damaging the covering.

storage
These products must be transported and stored in conditions that assure their protection from humidity. Storage must be done in a ventilated shelter. The packages must be slightly leaned to allow them to dry quickly; they must be raised off the ground to ensure that the material is well-aired and to stop moisture from stagnating and causing any damage to the panel covering. If the panels have been covered with a temporary protective lm, storage must be done away from direct and prolonged sunlight. The protective lm must be removed quickly, during panel installation. Generally, concerning the storage, transportation and handling of the panels, the AIPPEG recommendations should be followed. ISOPAN has been an AIPPEG member since its foundation.

warning
The colours shown in this leaet are interpretations of RAL colours; exposure to light may cause them to undergo some colour change over time.

68

ACCESSORIES

product
self-tapping screw

use

sizes (mm)

packets per box

For xing insulating panels and ribbed and wavy sheets to metal supports, requires pre-drilling. Suitable for use with structures up to 2.5 mm thickness.

6x20 mm 6x35 mm 6x50 mm 6x60 mm 6x100 mm 6x110 mm 6x120 mm 6x150 mm 6x160 mm 6x180 mm 6x200 mm 6x220 mm

100

self-piloting screw For xing insulated panels and ribbed and wavy sheets to metal supports, requires pre-drilling. Suitable for use with structures over 2.5 mm thickness. 6x20 mm 6x35 mm 6x50 mm 6x60 mm 6x100 mm 6x110 mm 6x120 mm 6x150 mm 6x160 mm 6x180 mm 6x200 mm 6x220 mm

100

self-drilling screw For xing insulated panels and ribbed and wavy sheets to metal supports, does not require pre-drilling, greatly reduces tting time and labour. 6x20 mm 6x35 mm 6x50 mm 6x60 mm 6x100 mm 6x110 mm 6x120 mm 6x150 mm 6x160 mm 6x180 mm

100

self-tapping screw for timber For xing insulated panels and ribbed and wavy sheets to timber supports. 6x100 mm 6x110 mm 6x120 mm 6x150 mm 6x160 mm 6x180 mm

100

69

ACCESSORIES
product
screw for Isodomus For xing Isodomus and LG50 panels to metal supports, requires pre-drilling. Suitable for use with structures up to 6 mm thickness. Also available for xing to timber structures. 6,3x70 mm 6,3x80 mm 6,3x120 mm 6,3x130 mm 100

use

sizes (mm)

packets per box

product
screw caps

use
Cover the head of the screw with a coloured cap in PVC.

colours
White Cream Pale grey Siena red Ebony

packets per box

250

capping Cappings in galvanised or prepainted steel, for xing insulated panels and ribbed sheets with screws. White Cream Pale grey Siena red Ebony Silver 9006

500

end-cover Fitting for closing off the ends of roong panels in the area of the gutter. Provides a better appearance if the nal section of the roof is open to view. White Cream Pale grey Siena red Ebony Silver 9006

profiled ridges To join the two pitches of the roof with a double hinged tting, proled to match the ribbing of the panels. White Cream Pale grey Siena red Ebony Silver 9006

70

product
gasket for Isofrigo

use
Expanding gasket to t into the joint in the Isofrigo panel for optimum seal and vapour barrier.

colours
Black

gaskets for Isolplast Gasket for on-site assembly of Isolplast sheets. Black

straight translucent Isolplast sheets Allow tting of xed skylights in single- or double-sheet roof. Transparent

curved translucent Isocarb sheets Allow tting of xed skylights in curved roofs. Transparent

71

OUR CERTIFICATES
Isopan panels have obtained technical approval from the strictest and most reputable international research institutes in Europe, charged with issuing such certication. In particular, the ITC (the Italian Institute for Construction Technology) has issued Technical Approval Certicates for our roong and wall panels. Many other European ofcial bodies have certied the quality of our manufactured goods, and also the compliance of the raw materials and the nished product with the strictest standards of the individual countries and of Europe. ISOPAN submits itself periodically to monitoring by the inspectors of the various Institutes, who oversee our production to ensure that the Approval standard is maintained. As regards national certicates, our brands of panel have been tested by the institutes authorised by the Interior Ministry.

Technical approval certicates


ITALY FRANCE GERMANY

SLOVAKIA

HUNGARY

ROMANIA

72

SLOVENIA

POLAND

UKRAINE

Other certicates
REFERENCE STANDARDS ITALY EUROPE EN 1363-1, EN 1364-1, EN 1365-2 EN 13501-1, EN 13823

FIRE RESISTANCE CLASS FIRE REACTION CLASS

Interior Ministry Circular no. 91 D.M. 26/06/1984

REFERENCE STANDARDS

MEASUREMENT OF SOUND ABSORPTION COEFFICIENT IN A REVERBERATION ROOM MEASUREMENT OF SOUND INSULATION POWER

UNI EN ISO 354 UNI EN ISO 140-3, UNI EN ISO 717-1

Certicates relating to panels in rock wool only. Certicates relating to panels in polyurethane and rock wool.
The ISOPAN Technical Ofce will anyway be very happy to supply the list of the certicates available, and to send out exact copies of the original. It is also possible to request the Declaration of Conformity of the product and to customise the request as required.

73

OUR CERTIFICATES

74

Spanish certicates

75

AIPPEG General Conditions of Sale for ribbed sheets, insulated metal panels and accessories

1. PARTIES TO THE CONTRACT

4. PACKAGING

By the Vendor party is meant the company which is the producer and/or the supplier of the manufactured goods which are the subject of the supply to which this contract refers, and which will issue invoices for the said goods. By Purchasing party is meant the addressee of the invoices relating to the manufactured goods to which this contract refers.
2. ORDER - ACCEPTANCE

The materials are supplied without packaging. Any packaging required must be requested at the time of placing the order and will be charged on the invoice.
5. TOLERANCES

The Purchaser accepts the tolerances stated in the Vendors catalogues and/or technical sheets (latest edition).
6. WARRANTY

The Purchasers order has the force of a proposal and is irrevocable for the term of thirty days. The Vendors conrmation has the force of acceptance and is the sole document which commits the parties and governs the contractual relationship, insofar as is not provided by the present General Conditions of Sale. For the purposes of acceptance of the order, the date which counts is the date indicated by the postmark or on the fax by which the conrmation is sent. In the event that the conrmation provides for the supply of goods belonging to different types and/or for split despatch, each type and/or despatch is treated as contractually independent of the others.
3. DELIVERY, DESPATCH AND TRANSPORT OF MATERIALS

The Vendor undertakes to comply with the agreed terms of delivery; a tolerance of fteen working days is however permitted. Circumstances which prevent or delay the production of the goods such as, by way of example but without limiting effect, strikes (including company strikes), lock-outs, res, prohibitions on imports, delayed resupply of raw materials or limitations of energy sources and other circumstances which prevent or delay fabrication, are agreed to be treated as cases of force majeure and the Vendor may not be held responsible for the delay in delivery. In the cases cited above, the Vendor may delay delivery for as long as the causes of the delay may last. In the event that the causes of the delay last for more than thirty days, the Vendor shall have the right to withdraw from the contract, without this implying the Purchasers right to the payment of compensation directly or indirectly attributable to the delay. Upon the expiry of the agreed terms of delivery, within fteen solar days of receipt of the notice that the merchandise is ready, the Purchaser shall collect the goods ordered, or, in the case of delivery to destination, shall request their despatch. When this term has expired, the goods may be stored in the open air, the Vendor being released from all responsibility, all warranties being void, and the costs of moving and storage being charged at the rate of 1% of the value of the goods for each week of storage; the Vendor furthermore reserves the right to despatch the goods carriage forward to the Purchaser, or to put them into storage at the Purchasers expense. Eight days after the issue of the advice that the merchandise is ready, a normal invoice shall in any event be issued, and the payment terms shall come into force. The Purchaser is obliged to check the goods at the time of delivery. The goods, even if sold carriage paid, always travel at the Purchasers risk and peril. Any evident defects and shortages must be reported at the time of delivery, under pain of voiding the relative warranty, by noting them on the packing list. Any demurrage, storage or waiting costs are payable by the Purchaser, even in the event that the merchandise is sold carriage paid and transport takes place by the Vendors vehicles or by vehicles commissioned by the Vendor.

Claims of any kind, with the exception of those specied in paragraph 3 above, must be made in writing (by registered post or telegram) to the Vendor within eight days of receipt of the products, it being understood after this period that the Purchaser will have forfeited all rights to warranty for defects and/or lack of quality and/or discrepancy in the goods sold. Claims must be detailed, to allow the Vendor to make a prompt and complete check. The goods which are the subject of a claim must be kept at the disposal of the Vendor, in the state in which they were delivered, in accordance with the rules on movement, handling and storage set out in Annexe A to the present General Conditions of Sale, and in accordance with any special instructions provided by the Vendor. Goods which present manifest defects must not be used by the Purchaser; failure to observe this provision entails the forfeiture by the Purchaser of all warranty. If the goods supplied prove to be unsuitable for the use for which they are intended, they will be replaced, with delivery to the point contractually agreed. The right of the Purchaser to cancel the contract is excluded, and any responsibility on the part of the Vendor for any direct and/or indirect damage suffered by the Purchaser is also excluded, but without prejudice to the limit provided by Article 1229 of the Civil Code. In the event of supply with split deliveries, any complaints, even if promptly made, shall not exonerate the Purchaser from the obligation to collect the remaining quantities of goods ordered. If the contentions should prove unfounded, the Vendor shall charge the costs of the inspections and of any reports, including reports by third parties. The Vendor guarantees the correspondence of the goods sold to the specications contained in its catalogues and/or technical sheets (latest edition). In the case of products faced with organic material, the warranty with respect to the facing is discharged, at the Vendors discretion, as follows: by means of execution by the Vendor of reinstatement works or by contribution to the cost of reinstatement to an amount not greater than three times the original price of the organic facing affected by defects; the amount of the contribution, as determined above, shall be progressively reduced in proportion to the period for which the product delivered has been in use. In the case of metal surfaces without organic facing, no warranty is issued, beyond their correspondence to the applicable regulations; the Vendor is exonerated from any responsibility in respect of the occurrence of oxidisation, this being a likely phenomenon. Warranty discharged by the Vendor shall not be renewed for the repaired parts.

76

Associazione Italiana Produttori Pannelli Elementi Grecati

The Vendor does not accept responsibility in the case of reinstatement carried out by third parties. Particular warranties and/or certications can be issued, if specically requested by the Purchaser when placing the order. All warranty is voided both by use not in accordance with the performance characteristics, and by failure to observe the rules on movement, handling and storage listed in Annexe A and any special instructions provided by the Vendor, as well as by the use of accessories functional to the use of the goods (such as, for example: xing systems, buffers, corrugation ends, ridges, sealing caps etc.) not supplied and/or not expressly approved by the Vendor. Calculation data, table values, materials estimates, graphic information and all other documents provided by the Vendor must be considered as simple guidance documents and do not imply any responsibility on the part of the Vendor; for purposes of specication and compliance with legislation, the design, supervision of works and testing remain in the exclusive competence, responsibility and care of the Purchaser. The Vendor reserves the right to introduce into its own products any modications or technical improvements as it considers necessary.
7. PRICE REVISION

Any claims or disputes, whether raised by way of legal action or by way of a plea, do not confer a right to suspend payments. If the payment for the goods is provided by bills of exchange or by means of credit instruments (cheques, bills of exchange etc.), these shall reach the Vendors address before or simultaneously with the collection of the goods. In the event of failure to pay at the specied due date, even of only a part of the price, the Purchaser shall forfeit the benet of delayed payments (term benet) even for supplies in progress; the Vendor furthermore may invoke the application of Articles 1460 and 1461 of the Civil Code. The account summary sent by the Vendor is deemed to be accepted by the Purchaser if it is not contested within fteen days of receipt.
9. WITHDRAWAL FROM THE CONTRACT

Prices are determined on the basis of costs in effect at the date of conrmation of the sale. In the event of the occurrence of increases larger than 2% in the cost of the goods, a price revision shall be made, which shall be applied at the time of invoicing, with full recognition of the actual variation in accordance with the percentage impacts indicated below: ribbed sheets: 10% labour, 90% metal panels: 10% labour, 30% insulating components, 60% external facings. For labour costs, reference shall be made to the tables produced by A.N.I.M.A. (National Federation of Mechanical, Engineering and related Industries); for metals, reference shall be made to the price list of the Milan Chamber of Commerce; for insulating components and other raw materials, reference shall be made to the declaration by the Vendors supplier. For accessories, the revision shall be carried out by agreement, applying any change in the ISTAT ofcial cost-of-living index. In cases where arrangements were made for split deliveries, the price revision shall be applied solely to the goods delivered subsequently to the occurrence of the price increases.
8. PAYMENTS

In addition to the cases specied in paragraph 3 above, the Vendor reserves the right to withdraw from the contract if acts or circumstances occur which alter the stability of the markets, the value of money, the condition of the industries producing the raw materials or the procurement conditions. The Vendor shall also have the right to withdraw from the contract without any charge, if cases come to light of dishonouring of bills on the part of the Purchaser, or the commencement of legal proceedings against the Purchaser, whether monitory, ordinary, insolvency or extrajudiciary proceedings.
10. GOVERNING LEGISLATION

Whatever is not expressly regulated by the present General Conditions of Sale, shall be governed by the regulations on sales provided by Article 1470 and following of the Civil Code, including cases of supply and tting of the goods.
11. JURISDICTION

Any dispute arising from the interpretation, application, execution or dissolution of the contract and/or of the present General Conditions of Sale or in any way relating to them, shall be referred exclusively to the jurisdiction of the court where the Vendor has its legal address, even in the event of joinder.

Payments shall be effected at the Vendors address. The collection by the Vendor of sums paid at the time of placing the order, does not constitute acceptance of the order. If the Vendor does not accept the order, it shall repay the sums received, without interest. In the event of default by the Purchaser, the sums paid on account shall be held by the Vendor by way of deposit, without prejudice to the Vendors right to recoup any larger damages; in the event of default by the Vendor, repayment shall be made of double the amount paid on account by the Purchaser, with the exclusion of any right to recoup any further damages. In the case of payments made late, the Purchaser shall pay delay interest under the terms of Legislative Decree 231/02, in addition to reimbursement of costs, at the ofcial key rate of interest plus seven percentage points, starting from the expiry date of the agreed term.

77

ANNEXE A Rules on movement, handling and storage of ribbed sheets, insulated metal panels and accessories

1. WRAPPING AND PACKAGING

Paragraph 9.9.1 of Standard UNI 10372:2004 is quoted in its entirety (text in italics). To maintain their durability in use, metal components for roofs must not be damaged during storage, transport, movement and laying operations. It is therefore advisable to provide temporary protection systems for the products relating to the performance required, especially of an aesthetic nature. During fabrication processes the above materials are generally protected with polythene lm (adhesive or simply in contact), or with other solutions. During subsequent stages precautions must be taken to ensure that the following aspects are guaranteed: - protection of the surface from abrasion, especially during movement; - protection of corners and edges against knocks and crushing; - protection against water or condensed moisture collecting; - protection of the components which bear the weight of the entire pack, or of superimposed packs, against permanent deformation. The proled sheets and panels are generally packaged in packs. The number of sheets in the pack is such as to contain the overall weight of the pack itself within the limits imposed by the available means of lifting and transport. Generally the materials used for packaging are: timber, expanded plastic materials, cardboard, polythene lm (heat-shrink or stretchable) or others; binding is done with bands (never with iron wire) and suitable protection is used (edge protectors etc.). The bands must not be used as slings for lifting. It is also advisable to provide attachment points for subsequent movement and lifting operations, indicating them appropriately. The packs of products must therefore always be provided with a support system which is such as to distribute the weight homogeneously and to make it possible to pick up the pack for movement. By way of example and without limiting effect, the support system may be constituted by joists made of expanded plastic material or dry timber, or alternatively by sheets of composite materials, located at suitable spacing for the characteristics of the product. The packaging must be appropriately specied at the ordering stage, depending on the modalities of transport (for example cage or crate for transportation which involves transshipment, or transport by train or by sea). A suitable type of packaging will need to be provided depending on the performance which is required of the product. The making-up of the packages will be performed according to parameters preset by the manufacturer. Any different division of components and/or particular packaging, in relation to specic requirements of the Purchaser, must be agreed at the time of placing the order.
2. TRANSPORT

which maintains the same curvature); - when stacking packs, suitable spacers made of timber or expanded plastic material are always interposed, if not present in the packaging; - the packs do not overhang by more than 1 metre; - the points are clearly marked on the packs where slings may be placed for lifting, if these are not otherwise identiable; - any other instructions from the manufacturer are observed. In particular, the packs must be positioned on the at, and underneath the packs themselves, spacers of timber or expanded plastic material must be placed, of suitable dimensions and in adequate numbers, positioned in perfect vertical alignment. The packs must be secured by the carrier to the transport vehicle by transverse ties, with straps placed at a maximum spacing of 3 m, and each pack must in any event be provided with no fewer than two transverse ties. When travelling, the load must always be covered, and above all the side facing in the direction of travel must be made impermeable. Purchasers arranging collection must instruct the drivers on the subject. The load must be carried on a vehicle bed which is clean and free of obstructions. Vehicles already partly occupied by other materials or with an unsuitable bed are not acceptable for the load. The goods must be positioned on the vehicles in accordance with the instructions of the carrier, who alone is responsible for the integrity of the load. The carrier must take particular care that the weight bearing on the lowest pack, and also the pressure exercised by the tie-points, do not cause damage, and that the straps do not in any way cause deformation of the product. Special loading conditions can be accepted only on the written proposal of the Purchaser, who assumes complete responsibility for them.
3. STORAGE

Paragraph 9.9.2 of Standard UNI 10372:2004 is quoted in its entirety (text in italics). The packs must be transported with suitable means in such a way that: - the packs are supported on spacers made of timber or expanded plastic material, located at spacing appropriate to the characteristics of the product; - the supporting surface is compatible with the shape of the pack (at if the pack is at, or if the pack is curved, a support must be created

Paragraph 9.9.3 of Standard UNI 10372:2004 is quoted in its entirety (text in italics). The shape of the components has been designed to allow them to be stored by stacking them so as to reduce to a minimum the space occupied in storage and transport; care must however be taken when stacking them so that no damage occurs to the surfaces. The packs must always be kept raised off the ground, both in the warehouse and, even more so, on site. They must have supports preferably of timber or expanded plastic material with at surfaces, with a length greater than the width of the sheets and at suitable spacing for the characteristics of the product. The supporting surface must be compatible with the shape of the packs (at if the pack is at, or if the pack is curved, a support must be created which maintains the same curvature). The packs must be stored in places which are not damp, otherwise condensation will collect on the less well-ventilated internal components. This condensation is particularly aggressive towards metals, and cause the formation of oxidisation products (for example white rust on zinc). The packs must be stored in such a way as to encourage water to drain, especially if it is necessary to store them temporarily in the open air (see illustration).

78

min. slope 5%

Lifting must preferably be carried out using slings woven from synthetic bre (nylon), of a width not less than 10 cm so that the load on the sling is distributed and does not cause deformation (see illustration).

If storage is not followed shortly by picking the sheets up for laying, it is as well to cover the packs with protective tarpaulins. Attention must be paid to any electrochemical corrosion caused by contact between different metals, including during the period of storage. Generally it is preferable not to stack the packs; if it is considered possible to stack them because of their light weight, spacers of timber or expanded plastic material, with as large a supporting surface as possible, must always be interposed, in suitable numbers and always located in line with the supports of the packs below (see illustration).
min. slope 5%

The best storage conditions are in closed areas, with light ventilation, free from damp and dust. In any event, and in particular for storage on site, a suitable, stable support surface must be provided, which will not allow water to collect. The packs must not be positioned in areas close to manufacturing processes, for example metal cutting, sanding, painting, welding etc., nor in areas where the crossing or parking of operating vehicles could cause damage (collisions, splashing, exhaust gases etc.). A maximum of three packs may be stacked, with an overall height of approximately 2.6 metres, and in this case the supports must be suitably thickened. In the event that the materials are covered with protective lm, this lm must be completely removed at the tting stage, and at all events not later than sixty days from the date of readiness of the materials. Any further specic instructions from the supplier must be followed. On the basis of knowledge acquired, in order to maintain the products original performance, it is advisable, subject to compliance with these rules, not to exceed six months of continuous storage in a closed and ventilated environment, while the period of storage in the open air must never exceed sixty days. The materials must anyway always be protected from direct solar radiation, because this can produce alterations. In the case of protection by tarpaulins, it is necessary to ensure that they are waterproof, and that there is adequate ventilation to avoid condensation collecting and pockets of water forming.
4. LIFTING AND HANDLING

Suitable spacers must be used consisting of robust lengths of at timber or plastic located above and below the pack, in order to prevent direct contact between the slings and the pack. These spacers must have a length at least 4 cm greater than the width of the pack, and a width not less than that of the sling. In any event, the lower spacers must have a width sufcient to prevent the weight of the pack from causing permanent deformation to the lower sheets. Care must be taken to ensure that the slings and the supports cannot move during lifting, and that the manoeuvres are performed gradually and with caution. When the packs are ofoaded onto the roof structure, they must be placed only on surfaces which are suitable for supporting them, both in terms of strength and of support conditions, and also in relation to other work which is in progress. It is advisable always to ask the works manager for authorisation for ofoading the packs. Suitable protective equipment must be used (gloves, safety shoes, overalls etc.) when handling the sheets, in compliance with the applicable regulations. When an individual sheet needs to be moved, this must always be done without dragging it over the one below. It should be rotated to a vertical position beside the pack and then carried by two or more people depending on its length, keeping it vertical (see illustration).

Paragraph 9.9.4 of Standard UNI 10372:2004 is quoted in its entirety (text in italics). The packs must always be lifted by slings positioned at a minimum of two points, separated by a distance not less than half the length of the packs themselves.

Gloves and lifting equipment must be clean and of a kind that will not cause damage to the sheets. The use of fork-lift trucks for moving the sheets is not recommended, as this is likely to cause damage. Packs ofoaded at roof height must be suitably secured to the structure.

79

ANNEXE B Quality standards for ribbed sheets and insulated metal panels
Ribbed sheets and insulated metal panels are used for walls, roofs and oors in civil and industrial buildings. The quality standards quoted in the present Annexe must be the subject of prior agreement between Purchaser and Vendor at the time of conrming the order. The aesthetic factor lies outside the intrinsic characteristics of the products and does not constitute a normal supply requirement. The harmonised European product standards, valid for obtaining CE Marking, are UNI EN 14782:2006 and UNI EN 14783:2006 for ribbed sheets, UNI EN 14509:2007 for double-skinned insulated metal panels (with two metal sheets), and ETAG 016 for single-skin insulated metal panels.

Materials 1. RIBBED SHEETS 1.1 CHARACTERISTICS 1.1.1 Carbon steel

Standard UNI EN 14782:2006 UNI EN 14783:2006 UNI EN 508-1:2002 UNI EN 10326:2004 UNI EN 10327:2004 UNI 10372:2004 UNI EN 14782:2006 UNI EN 14783:2006 UNI EN 508-2:2002 UNI 10372:2004 UNI EN 573-3:1996 UNI EN 1396:1998 UNI EN 14782:2006 UNI EN 14783:2006 UNI EN 508-3:2002 UNI 10372:2004 UNI EN 10088-1:2005 UNI EN 10088-2:2005 UNI EN 14782:2006 UNI EN 14783:2006 UNI EN 506:2002 UNI 10372:2004 UNI EN 1172:1998 UNI EN 1173:1998 UNI EN 1412:1998 UNI EN 508-1:2002 UNI EN 10326:2004 UNI EN 10327:2004 UNI 10372:2004 UNI EN 10169-1:2007 UNI ENV 10169-2:2003 UNI EN 10169-3:2006 UNI EN 508-1-2-3:2002 UNI 10372:2004 UNI EN 1396:1998 UNI EN 14782:2006 UNI EN 14783:2006 UNI EN 508-1:2002 UNI 10372:2004

Reference

Value - notes

1.1.2 Aluminium

3.2 and 4.2 5.1 and 7. 5.1 and 7. 8.1.4 3.2 and 4.2 8.1.2 3. 5. 3.2 and 4.2 8.1.3 4. 6. 3.2 and 3.4 8.1.1 459 3. 4. 3.2 and 3.4 7. 7. 8.1.4

S250GD DM (min. yield stress = 250 N/mm2) Non-structural steels

Alloys: Vendors declaration (min. breaking load = 150 MPa)

1.1.3 Stainless steel

Type 1.3401 (AISI 304)

1.1.4 Copper

Type: Vendors declaration (except by specic request of the Purchaser, accepted by the Vendor)

1.1.5 Metal facings

1.1.6 Organic facings (prepainted and plasticised)

Including different facings

1.1.7 Multi-layer bituminous facings

Annexe B 8.1.4.3 6. Annexe A Annexe A 3.2.6 8.1.4.4 Normal tolerances unless requested otherwise

1.2 DIMENSIONAL TOLERANCES 1.2.1 Carbon steel UNI EN 10143:2006 UNI EN 508-1:2002 1.2.2 Aluminium UNI EN 485-4:1996 UNI EN 508-2:2002 1.2.3 Stainless steel UNI EN 10088-2:2005 UNI EN 508-3:2002 1.2.4 Copper UNI EN 1172:1998 UNI EN 506:2002 UNI EN 1172:1998 1.3 REQUIREMENTS 1.3.1 Performance UNI EN 14782:2006 UNI EN 14783:2006 D.M. 09.01.1996 D.M. 14.09.2005 Directive 89/106/EEC UNI EN 13523-024 UNI EN 10169-1:2007 ENV 10169-2:2003 UNI EN 10169-3:2006 UNI EN 1396:1998

Appendix D 3.1 Appendix B 6.9 Appendix B 6.4 Appendix A

Annexe B

1.3.2 Test methods (metallic coated tapes) 1.3.3 Durability

Part II 11.2.4.8.1.1 Annexe 1

Values declared by the Vendor for the purposes of CE Marking Values declared by the Vendor

80

Materials 1.3.4 Fire behaviour 1.3.5 Calculation procedures (concentrated loads) 1.3.6 Inspection and maintenance

Standard UNI EN 14782.2006 UNI EN 14783:2006 UNI EN 14782:2006 UNI 10372:2004 AIPPEG general conditions of sale

Reference Annexe C Annexe B Annexe B Chap. 11 Annexe D

Value - notes

2. INSULATED METAL PANELS (DOUBLE SKINNED) 2.1 CHARACTERISTICS 2.1.1 Rigid metal facings The same references apply as in para. 1.1 above (excluding the specic prescriptions of UNI EN 14782:2006 and UNI EN 14783:2006) 2.1.2 Insulants 2.1.2.1 Rigid cellular UNI EN 13165:2006 PUR and PIR plastics UNI EN 13164:2006 Polystyrene UNI EN 13172:2003 Evaluation and conformity 2.1.2.2 Mineral bre UNI EN 13162:2003 2.2 DIMENSIONAL TOLERANCES 2.2.1 Rigid metal facings 2.2.2 Panel 2.2.3 Blisters The same regulations, references, values and notes apply as in para. 1.2 above UNI EN 14509:2007 Annexe D Blisters are dened as convex areas with a lack of adhesion between insulation and facing. In the absence of regulations, it is considered on the basis of experience that any blisters up to 5% of the area of the individual panel and with maximum dimensions per blister of 0.2 m2 are to be presumed not to prejudice the functionality of the panel. The above is to be considered valid even for panels where the insulation has the function of transmitting loads. UNI EN 14509:2007 UNI 10372:2004 Directive 89/106/CEE UNI EN 14509:2007 UNI EN 14509:2007 UNI EN 14509:2007 UNI EN 14509:2007 UNI 10372:2004 AIPPEG general conditions of sale Paras. 5 and 6 Para. 8.1.6 Annexe 1 Annexe A Annexe B Annexe C Annexe E Chap.11 Annexe D

2.3 REQUIREMENTS 2.3.1 Performance 2.3.2 Test methods 2.3.3 Durability 2.3.4 Fire behaviour 2.3.5 Calculation procedures 2.3.6 Inspection and maintenance

Values declared by the Vendor for the purposes of CE Marking

3. INSULATED METAL PANELS (SINGLE SKINNED) 3.1 CHARACTERISTICS 3.1.1 Rigid metal facings The same references apply as in para. 1.1 above (excluding the specic prescriptions of UNI EN 14782:2006 and UNI EN 14783:2006) 3.1.2 Insulants 3.1.2.1 Rigid cellular plastics UNI EN 13165:2006 UNI EN 13164:2006 UNI EN 13172:2003 PUR and PIR Polystyrene Evaluation and conformity

3.2 DIMENSIONAL TOLERANCES 3.2.1 Rigid metal facings The same regulations, references, values and notes apply as in para. 1.2 above 3.2.2 Panel ETAG 016 Parts 1 and 2 Values declared by the Vendor 3.2.3 Blisters Reference Para. 2.2.3 3.3 REQUIREMENTS 3.3.1 Performance 3.3.2 Other requirements 3.3.3 Inspection and maintenance UNI 10372:2004 Directive 89/106/CEE ETAG 016 UNI 10372:2004 AIPPEG general conditions of sale Para. 8.1.6 Annexe 1 Parts 1 and 2 Chap. 11 Annexe D

Values declared by the Vendor for the purposes of CE Marking Values declared by the Vendor

National and European regulations, as well as the needs of the market, are in a state of continuous evolution. The members of AIPPEG are available to examine requests for products with qualitative standards different from the performance characteristics quoted in the present Annexe.

81

ANNEXE C Recommendations for tting ribbed sheets and insulated metal panels

1. INTRODUCTION

These recommendations are intended to provide a reference informational support for tting ribbed sheets and insulated metal panels. They are however supplementary to Standard UNI 10372:2004 Discontinuous roong. Code of practice for design and execution with metal sheets. Each job must take account of the needs of the specic site, which must be provided with suitable equipment for movement and laying, in accordance with the applicable legislation on safety and accident prevention. The rm charged with the job of tting the ribbed sheets/panels, besides knowing the characteristics of the materials used, must employ sufcient skilled manpower for the work on site, ensuring that the work is correctly performed in compliance with the plan specications. Failure to observe these recommendations and incorrect execution of the operations on site exonerate the Vendor from all responsibility. Efcient organisation and a coordinated method of working provide the best conditions for overall working productivity. Irrespective of the delivery location of the goods, the operations referred to in Annexe A, as well as those of unloading and installation, are carried out under the care and responsibility of the Purchaser, unless otherwise agreed. The instructions on the subject provided by the Vendor must be strictly followed.
2. CONSTRUCTION COMPONENTS

2.2 monolithic insulated panels 2.2.1 prefabricated monolithic sandwich 3. FLOORS 3.1 plain sheets 3.2 sheets with collaborating concrete 3.3 ribbed sheets with disposable formwork The tting sequence for roofs, walls and oors is different depending on the type involved.
3. PRELIMINARY OPERATIONS

Ribbed sheets/panels are used in civil and industrial buildings for the construction of roofs, walls and oors; they are tted to every kind of supporting structure: metal frameworks, normal reinforced and prestressed concrete, and timber. The supporting structures and the relative xing devices as well as the ribbed sheets/panels themselves, must be suitably dimensioned and must satisfy the intended design conditions in respect of safety, stability and functionality. Ribbed sheets and insulated metal panels are quick and easy to install, with the possibility of covering in one stretch the entire length of the slope of a roof, or the entire height of a wall or several spans of the oor. The length of the metal components is conditioned predominantly by transport and handling needs, as well as by the nature of the material used and the production technology. The supporting surfaces should be compatible with the use and the xing modalities of the ribbed sheets and insulated metal panels. The most common types are: 1. ROOFS 1.1 ribbed sheets 1.1.1 plain ribbed sheets 1.1.2 sandwich construction executed on site 1.1.3 deck executed on site 1.2 monolithic insulated panels 1.2.1 prefabricated monolithic sandwich 1.2.2 pre-insulated deck 2. WALLS 2.1 ribbed sheets 2.1.1 plain ribbed sheets 2.1.2 sandwich construction executed on site

Before undertaking the work of tting on site, the installer must: 1. view the printouts of the plans and study the relative instructions 2. check the alignment of the supporting structures for the ribbed sheets/panels 3. check that the surfaces of the supporting structures which will be in contact with the ribbed sheets/panels, are compatible with each other or otherwise protected from possible corrosion by electrochemical action 4. make sure that there is no interference with aerial electrical lines in the manoeuvring area for the ribbed sheets/panels 5. make certain that the work at ground level and at a height is compatible with the other work on site 6. check the suitability of the area of the site chosen for the ofoading and handling of materials, so that they do not suffer damage. The installer must carry out all tting operations in accordance and compliance with all applicable safety regulations. In addition, for lifting, handling and ofoading the ribbed sheets/panels at height, see Paragraph 4 of Annexe A. Personnel engaged in tting must be equipped with footwear with soles that will not damage the external facing. For cutting operations on site, suitable equipment must be used (jigsaw, shears, nibbler etc.). The use of equipment with abrasive discs is not recommended. For xing operations it is advisable to use a power screwdriver with torque limiter. For roong work in particular, the alignment and overlap of adjoining panels must be perfectly carried out to avoid the formation of condensation
4. ROOFS

SLOPES The slope of the roof depends on the environmental conditions, the design solution chosen and the type of roof itself. For roofs with pitch without intermediate end-to-end joints (i.e. with sheets of a length equal to the length of the roof), the slope to be adopted is usually not less than 7%. For lower slopes the suppliers instructions must be followed. In cases where there is an end-to-end overlap, the slope must take account of the type of joint and the material used, besides the specic environmental conditions. For deck roofs, the slope may be reduced to the minimum which will allow the water to drain off properly.

82

FITTING SEQUENCES These are the essential points for a correct tting sequence.
A) Plain ribbed sheets and prefabricated monolithic sandwich (types 1.1.1 and 1.2.1)

B.2) Sandwich construction with crossed ribbed sheets

1. Fit the gutters and any under-ridge pieces and connecting ashings. 2. Remove any protective lm from the roong panels/sheets and from the accessories. 3. Lay the roong panels/sheets starting from the eaves and from one end of the building, taking care to align and overlap the panels/sheets correctly and to check that they are perfectly square with respect to the underlying structure. 4. Secure the panels/sheets systematically, after checking that they are perfectly lined up. All left-over materials must be promptly removed, with particular attention to metal offcuts. 5. Lay subsequent courses of panels/sheets overlapping the eaves course (in the case of a pitch requiring two or more courses). In the case of panels, the insulation must rst be removed in the overlap area. 6. Fix the panels/sheets at every rib along the lines of the ridge, eaves, valleys and end-to-end overlaps. 7. Fit the nishing parts (ridges, cappings and ashings in general) and any corresponding insulation. 8. Remove all left-over materials and make a general inspection of the roof, with particular attention to the xings and the areas connecting with other elements making up the roof.
B) Sandwich construction executed on site (type 1.1.2)

1. Remove any protective lm from the roong sheets and from the accessories. 2. Lay the inner sheets starting from the eaves and from one end of the building, taking care to align and overlap the sheets correctly and to check that they are perfectly square with respect to the underlying structure. 3. Secure the sheets systematically, after checking that they are perfectly lined up. All left-over materials must be promptly removed, with particular attention to metal offcuts. 4. Fit the ashing pieces which connect to the rst sheet (under-ridge pieces, connectors, special components). 5. Fit suitably-sized rigid spacing pieces, positioned as on the plans. In the case of metal spacing pieces, it is advisable to provide a thermal break between these distance pieces and the outer ribbed sheet. In the event that the inner sheet consists of continuous metal strips, the spacers are not necessary, but it is always advisable to provide a thermal break. 6. Lay the insulation (taking care to ensure that the thermal insulation is uniform) and any layers which have a specic function (e.g. vapour barriers, separating layers etc.), and any head-end buffers. 7. Lay the outer sheet, following steps 18 of sequence A (Plain ribbed sheet).
C) Deck executed on site (type 1.1.3) and pre-insulated deck (type 1.2.2)

B.1) Sandwich construction with parallel ribbed sheets 1. Fit the gutters and any connecting ashings: depending on the plan specications, this may be done before laying the inner sheet or before laying the outer sheet. 2. Remove any protective lm from the roong sheets and from the accessories. 3. Lay the inner sheet starting from the eaves and from one end of the building, taking care to align and overlap the sheets correctly and to check that they are perfectly square with respect to the underlying structure. 4. Secure the sheets systematically, after checking that they are perfectly lined up. All left-over materials must be promptly removed, with particular attention to metal offcuts. 5. Lay subsequent courses of sheets overlapping the eaves course (in the case of a pitch requiring two or more courses). 6. Fix the sheets at every rib along the lines of the ridge, eaves, valleys and end-to-end overlaps. 7. Fit suitably-sized rigid spacing pieces, positioned as on the plans. In the case of metal spacing pieces, it is advisable to provide a thermal break between these distance pieces and the outer ribbed sheet. If the secondary support structure provides a direct housing for the inner sheet, the rigid spacing pieces mentioned above are superuous. 8. Lay the insulation (taking care to ensure that the thermal insulation is uniform) and any layers which have a specic function (e.g. vapour barriers, separating layers etc.), and any head-end buffers. 9. Lay the outer sheet, following steps 26 of sequence B1. 10. Remove all left-over materials and make a general inspection of the roof, with particular attention to the xings and the areas connecting with other elements making up the roof.

Follow the tting instructions for the inner sheets in sequence B.1. Carry out the seam xing along the longitudinal overlaps. In the case of decks executed on site, the insulation is provided by the insulant applied subsequently. In the case of pre-insulated decks, temporary local removal of the insulation needs to be carried out before xing. The seal is provided by the layers applied subsequently (bituminous sheathing or synthetic membrane etc.).
5. WALLS

FITTING SEQUENCES The following are the essential points for a correct tting sequence.
A) Plain ribbed sheets and prefabricated monolithic sandwich (types 2.1.1 and 2.2.1)

1. Fit the base ashing (when specied) at the foot of the wall, aligned with the level of the supporting structure, as well as the ashing which necessarily has to be tted before the wall (drip above the window-frames, connectors for openings, internal corner connectors etc.), after removing any protective polythene lm. 2. Remove any protective lm from the wall panels/sheets. 3. Fit the panels/sheets starting from the foot of the wall, taking care that joints are correctly aligned and executed, and checking that the panels are upright. 4. Secure the panels/sheets systematically, after checking that they are perfectly lined up. 5. In the event that the height of the wall or the nature of the material necessitates tting successive courses of sheets/panels in vertical sequence, the joints must be made in line with a frame element of the structure. The procedure is as follows: - at panel: butt joint, with a suitably-proled connecting ashing

83

between the panels - ribbed panel and ribbed sheet: like at panel but sealed by means of an overlap. 6. Fit the nishing components (corner strips, perimeter edging, wallto-roof connectors etc.). 7. Carry out a general inspection and cleaning of the wall, paying particular attention to the xings and the joints with the door and window frames, and with other components of the wall itself. In the case of walls with horizontally positioned ribbed sheets/panels, refer to the plan specications.
B) Sandwich construction executed on site (type 2.1.2)

B.1) Sandwich construction with parallel ribbed sheets 1. Fit the base ashing (when specied) and any connecting ashings: depending on the plan specications, this may be done before tting the inner sheet or before tting the outer sheet, after removing any protective polythene lm. 2. Remove any protective lm from the wall sheets. 3. Fit the sheets starting from the foot of the wall, taking care that joints are correctly aligned and executed, and checking that the panels are upright. 4. Secure the sheets systematically, after checking that they are perfectly lined up. 5. In the event that the height of the wall or the nature of the material necessitates tting successive courses of sheets in vertical sequence, the joints must be made by overlapping the sheets in line with a frame member of the structure. 6. Fit suitably-sized rigid spacing pieces, positioned as on the plans. In the case of metal spacing pieces, it is advisable to provide a thermal break between these distance pieces and the outer ribbed sheet. If the secondary support structure provides a direct housing for the inner sheet, the rigid spacing pieces mentioned above are superuous. 7. Lay the insulation (taking care to ensure that the thermal insulation is uniform) and any layers which have a specic function (e.g. vapour barriers, separating layers etc., according to the particular requirements dictated by the use of the building). This operation must be carried out simultaneously with tting the inner sheet. 8. Fit the outer sheet, following steps 25 of sequence B.1. 9. Fit the nishing components (corner strips, perimeter edging, connectors to the roof and to the walls etc.). 10. Carry out a general inspection and cleaning of the wall, paying particular attention to the xings and the joints with the door and window frames, and with other components of the wall itself. B.2) Sandwich construction with crossed ribbed sheets 1. Remove any protective lm from the wall sheets and from the accessories. 2. Fit the sheets starting from the foot of the wall, taking care that joints are correctly aligned and executed. 3. Secure the sheets systematically, after checking that they are perfectly lined up. 4. Fit the ashing pieces which connect to the rst sheet (connectors, special components etc.). 5. Fit suitably-sized rigid spacing pieces, positioned as on the plans. In the case of metal spacing pieces, it is advisable to provide a thermal break between these distance pieces and the outer ribbed sheet. In the event that the inner sheet consists of continuous metal strips, the spacers are not necessary, but it is always advisable to provide a

thermal break. 6. Fit the base ashing (when specied) at the foot of the wall. 7. Fit the insulant (taking care to ensure that the thermal insulation is uniform) and any layers which have a specic function (e.g. vapour barriers, separating layers etc., according to the particular requirements dictated by the use of the building). This operation must be carried out simultaneously with tting the outer sheet. 8. Fit the outer sheet, following steps 25 of sequence B.1. 9. Fit the nishing components (corner strips, perimeter edging, connectors to the roof and to the walls etc.). 10. Carry out a general inspection and cleaning of the wall, paying particular attention to the xings and the joints with the door and window frames, and with other components of the wall itself.
6. FLOORS

FITTING SEQUENCES The following are the essential points for a correct tting sequence.
A) Plain sheets (type 3.1)

1. Fit any perimeter ashings. 2. Remove any protective lm from the oor sheets. 3. Lay the sheets, taking care to butt or overlap them correctly. Check that they are perfectly aligned and square with the underlying structure. 4. Secure the sheets systematically according to the plan specications, after checking that they are perfectly lined up. Carry out the seam xing along the longitudinal overlaps. All left-over materials must be removed, with particular attention to metal offcuts. 5. Finish the oor according to the plan specications, avoiding stressing the oor panels with concentrated loads.
B) Sheets with collaborating concrete (type 3.2)

1. Erect the formwork for containing the poured concrete. 2. Lay the sheets taking care to butt or overlap them correctly. Check that they are perfectly aligned and square with the underlying structure. 3. Secure the sheets systematically according to the plan specications, after checking that they are perfectly lined up. Carry out the seam xing along the longitudinal overlaps. Check that the ribbed sheets are free of oxides and oil stains and any other substances which would prevent adhesion to the concrete. All left-over materials must be removed, with particular attention to metal offcuts. 4. To avoid leakage of concrete at end-to-end joints between the ribbed sheets, apply a strip of adhesive sealing tape. 5. Position the welded mesh and/or any reinforcing steel in line with the supports or located by supplementary supports, depending on the plan specications. 6. Pour the concrete, avoiding accumulations especially in the central area of the span. 7. If the plan specications require the use of props to break up the spans, these must obviously be positioned before pouring the concrete, providing the ribbed sheets with any necessary braces against deformation.
C) Ribbed sheets with disposable formwork (type 3.3)

1. Erect the formwork for containing the poured concrete.

84

The tting instructions for sequence B apply, except for point 5, in which the reinforcing steel is obviously obligatory.
7. FIXING DEVICES

8. FINISHING COMPONENTS

The xing devices are an essential part of the roong, wall and oor system. For this reason it is essential to use the xing devices specied by the manufacturer of the ribbed sheets/panels. Correct tting requires the following: For roofs: - external facing (types 1.1.1 1.1.2 1.2.1): a complete set usually made up of screws, caps and the relative sealing gaskets, to be located at the crest of the ridge: - external facing (types 1.1.2 1.1.3 1.2.2): screws with any gasket required For walls: - external facing (types 2.1.1 -2.1.2 -2.2.1): screws with gasket - internal facing (type 2.1.2): screws with any gasket required - prefabricated monolithic panels with concealed xings: specic xing kit For oors: screws, nails, washers to be welded on site. The density and positioning of the xings depends on the characteristics of the building component, on the type and size of supports, and on the local climatic situation (winds in particular). Refer in any event to the plan specications. In the most frequently-occurring situations, the ribbed sheets/panels are xed by means of screws which are different depending on the type of supporting structure.
1. Fixing to a metal framework:

The nishing components are an integral part of the job and make a decisive contribution to determining the projects performance characteristics. The manufacturer of ribbed sheets/panels is generally able to supply the nishing components, which must be used in accordance with the plan and/or supply specications. The Purchaser must specify the type and range of nishing components which are of interest, depending on the requirements of the job. The manufacturer of ribbed sheets/panels is responsible for the conformity of materials to the conrmed order, solely and exclusively for those parts directly supplied and correctly used. The nishing components include variously proled gaskets, metalwork (ridges, under-ridge pieces, guttering, valleys and downpipes, ashings, drips, corner strips etc., translucent sheets, domes, ventilators, door and window frames and accessory components.

- self-tapping screws and thread-forming/self-piloting screws (depending on the thickness of the support) - self-drilling screws - nails shot from a nail gun (for oors and inner sheets in on-site sandwich construction) - threaded hooks with nut (in general for anchorage to tubular components)
2. Fixing to a timber framework:

- woodscrews - threaded hooks


3. Fixing to reinforced and pre-stressed concrete:

Fixing is to steel or timber support components by the methods listed in paragraphs 1 and 2. Direct xing to reinforced and pre-stressed concrete is not recommended. For deck roofs and for oors, seam xing must be used, generally by means of rivets, along the longitudinal overlap, at not more than 1000 mm seam xing centres. For other roong and wall components, seam xing is recommended, depending on the shape of the overlap.

85

ANNEXE D Instructions for the inspection and maintenance of roofs and walls in insulated metal panels and ribbed sheets
All buildings require a periodic systematic inspection and programmed maintenance, in order to ensure that the building will continue to function over time and maintain the required performance. The checks to be performed at the time of the inspection are intended to be addressed both to the roof and wall components, and to the complementary works (joints, xing devices, ridges, ashings, snow barriers, gutters, hips etc.), and to any technological equipment present (chimneys, smoke extractors, lightning protection etc.). 1.1 During and immediately after the completion of tting the insulated metal panels or ribbed sheets, it is the responsibility of the installing rm to arrange the removal of all the materials no longer necessary, including any traces of the temporary protection lm. In particular, the rm must take the greatest care in removing metal swarf and abrasive items which have been deposited on the roof. The work can only be signed off after the building envelope (i.e. the roof and walls, including the nishing components and in particular the gutters) has been adequately cleaned and is free from all extraneous material. 1.2 Inspections must be carried out at regular intervals. The rst one must coincide with the signing-off of the works executed or with the corresponding test inspection. The test must be addressed both to the functionality of the specic operations performed (roof and/or walls) and to the building in its entirety according to the plan specications or as regards compliance with the contractual relationship between the Purchaser and the supplier, general contractor or tting rms. Inspections must take place at six-monthly intervals (preferably in the spring and autumn of each year). At the rst inspection, to be carried out by the installing rm or by the purchaser/owner according to what is specied in the contract or agreed between the parties, a check must be made to ensure that no extraneous materials or swarf from the work have been abandoned which could give rise to corrosion or damage with respect to the building envelope, or which could impede the correct drainage of rainwater. It is in any event necessary to check that an accumulation of undesirable substances cannot be produced, such as dust, sand, leaves etc. It is also desirable for the purchaser/owner to be notied of potential weak points (such as lack of surface protection) over the entire building envelope, which could be sources of corrosion (for example by electrochemical action), with consequent premature deterioration also as regards the appearance of the building (rust stains, for example). A comment should also be made on the location of the building: the purchaser/owner should be told about the type of atmosphere on the site, in relation to possible sources of accelerated corrosion (such as smoke) caused by adjacent buildings. The existing type of atmosphere should be known before purchasing the materials. Subsequent inspections consist of a check on the general condition of the building envelope: state of conservation (i.e. durability) and functionality both of the ribbed sheets and/or insulated metal panels and of all the nishing and complementary components, including ridges, ashings, gutters, tightness of the xings and any sealing which could have an effect on the building envelope. The progress of ageing should be monitored, both physiological and pathological, so that any necessary ordinary and extraordinary maintenance can be scheduled. At the same time, the efciency of the system for draining rainwater, and of the other technological equipment should be checked.
2. MAINTENANCE 1. INSPECTION

2.1 The building envelope, like any other product, must be periodically checked so as to detect in good time any problems which are about to occur and be able to deal with them promptly, thus reducing maintenance work to a minimum. Maintenance operations must also be addressed to the principal nishing components (for example, anchoring devices and the interface with the supporting framework, and the secondary ones (for example rainwater downpipe inlets) which could compromise the overall functionality of the building envelope. 2.2 Programmed ordinary maintenance must be established and carried out by the owner, on items and at intervals which depend

on the results of the inspections as well as on the general condition of the building and the existing environmental situation, as well as the conditions of use. It is in any event aimed at maintaining and adjusting to the functional needs of the fabric. It may be sufcient to carry out regular cleaning of the surface of the roof and walls. Localised repairs my be necessary due to breakages, scratches and damage. Any dirt stains indicate the evaporation of liquids which have run down the surfaces. During maintenance, therefore, besides removing the stains, it is necessary to eliminate the cause of water collecting (such as movement of the gutters in which it runs, settlement of the framework or distortion of the ridges, ashing etc.). 2.3 If the results of the inspections establish that there are conservation problems at work, an extraordinary maintenance operation must be performed by the owner and at his/her expense, with the aim of restoring the initial conditions. These operations are intended to address the premature occurrence of problems of corrosion of the metal components, not envisaged at the design stage. These problems can arise from a general situation of the fabric being compromised by nishing works not meeting expectations in terms of durability, or from factors not pertaining to the works, such as ooding, ageing, condensation, electrochemical incompatibility, new sources of pollution, change of use etc. The present Instructions govern the contractual relations between the Vendor party and the Purchasing party (addressee of the invoice). Failure to carry out or incorrect execution of inspection and maintenance operations exonerates the Vendor from all responsibility in the period between the despatch of the materials and the time limit for their presumed involvement under the terms of the applicable legislation (Article 1495 of the Civil Code, and Legislative Decree no. 24 of 2 February 2002). The Purchasing party undertakes on its own account to adopt and to see that third parties concerned adopt the present Instructions, to the extent that they are limited to the obligations on the part of the Vendor provided by the applicable legislation (regarding instructions, limitations and expiry). Third parties concerned and involved by the Purchaser is to be understood as meaning: trading companies, construction rms, tting operators, contracting and commissioning organisations, and owners of the premises and subsequent owners who may take part in the transfer of ownership. The commitment to inspection and maintenance is undertaken by the Purchasing party in relation to the Vendor party. The Purchasing party is to transmit the present commitment in its turn when it in its turn becomes a vendor, and so forth in succession as far as the owner of the premises. For validation of the inspection and maintenance operations, the owner must in any event sign the acceptance of the commitment, on its own responsibility and at its own expense, to carry out inspection and maintenance operations. These operations are to be recorded in chronological order in a suitable register with all the technical checks noted, and with the description of the ordinary maintenance jobs and any extraordinary maintenance jobs performed. This register is to be set up on the initiative of the owner, and maintained and updated by the owner or by the building administrator under delegation from the owner. The register must be available and consultable as a document recording the proper management of the premises, always within the context of the Vendors relevant legal conditions. The register must contain a record of the supply of the insulated metal panels and ribbed sheets, stating the name of the supplier, the details of the order conrmation, the type and characteristics of the materials (including catalogue references), the date of delivery to the site and the relative transport documents, and the subsequent chronology of the installation. The names and addresses must also be entered in the register of: the designer, the works manager, the site safety manager, the tester, the main contractor and the tting contractor (or the individual operators). The identiability and traceability of the supplies must thus be ensured for the entire duration of the validity of the present Instructions, which will terminate with the cessation of the relationship with the company producing the insulated metal panels or the ribbed sheets, with respect to its possible involvement under the terms of the law.

86

Via A. Righi, 7 I - 37135 VERONA Tel. 0039 0458088911 Fax 0039 0458204829 gruppomanni@gruppomanni.it www.gruppomanni.it
Headquarters: Via A. Righi, 7 I - 37135 VERONA Tel. 0039 0458088911 Fax 0039 0458204829 mannisipre@gruppomanni.it www.mannisipre.it Campoformido Centre: Via Principe di Udine, 118 I - 33030 CAMPOFORMIDO (UD) Tel. 0039 0432653611 Fax 0039 0432653600 Crema Centre: Via Gaeta, 23 I - 26013 CREMA (CR) Tel. 0039 0373890011 Fax 0039 037382662 - 037382364 Headquarters and factory: Via Scopa, 20 I - 63033 MONTEPRANDONE (AP) Tel. 0039 073571051 Fax 0039 0735751312 malavolta@gruppomanni.it www.malavolta.it Verona Centres:

S.p.A.

1) Via A. Righi, 9 2) Via dellEsperanto, 20/a

UNI EN ISO 9001:2008 Cert. N. 3185/2

UNI EN ISO 14001:2004 Cert. N. 0442A/0

OHSAS 18001:2007 Cert. N. 0079L/0

I - 37135 VERONA Tel. 0039 0459214666 Fax 0039 045500782 Goito Centre: Strada Statale 236 Goitese 5/a I - 46044 GOITO (MN) Tel. 0039 0458088040 Fax 0039 0376689487 Mozzecane Centre: Via Mediana I - 37060 MOZZECANE (VR) Tel. 0039 0456339400 Fax 0039 0456339435 - 0457930025 Factory: Via Ignazio Silone I - 60035 JESI (AN) Tel. 0039 073571051 Fax 0039 0731616032

ISO 3834-2 Cert. N. 2/IT/242

UNI EN ISO 9001:2008 Cert. N. 3185/2

UNI EN ISO 14001:2004 Cert. N. 0442A/0

OHSAS 18001:2007 Cert. N. 0079L/0

ISO 3834-2 Cert. N. 2/IT/242

Verona Centre: Via Torricelli, 21 I - 37135 VERONA Tel. 0039 0458088010 Fax 0039 045509058 csi@gruppomanni.it Headquarters and factory: Via Marchionale, 72/D I - 46046 MEDOLE (MN) Tel. 0039 0376898150 Sheets factory fax 0039 0376868335 Tubes factory fax 0039 0376899069 cmm@gruppomanni.it www.cmmlaser.it
Isopan is member of GBC Italia

UNI EN ISO 9001:2000 Cert. N. 9645

ISO 9001:2000 Cert. N. 501002347- Rev. 3

Headquarters and factory: Strada Prov. Morolense - Z.I. I - 03010 PATRICA (FR) Tel. 0039 07752081 Fax 0039 0775293177 isopan@gruppomanni.it www.isopan.it Headquarters and factory: Polgono Industrial de Constant Av.da de les Puntes - Parcela, 23 E - 43120 CONSTANT (TARRAGONA) Tel. 0034 977524546 Fax 0034 977524597 isopan@isopan.es www.isopan.com Headquarters and factory: Sos. de Centura 109 Popesti Leordeni RO - 077160 - jud. ILFOV Tel. 0040 21 3051600 Fax 0040 21 3051610 isopanest@gruppomanni.it Legal registered office: Via A. Righi, 7 I - 37135 VERONA Tel. 0039 04588088911 Fax 0039 0458204829 info@icomengineering.com www.icomengineering.com

Factory: Via Giona, 5 I - 37060 TREVENZUOLO (VR) Tel. 0039 0457359111 Fax 0039 0457359100 isopan@gruppomanni.it

DIN EN ISO 9001:2008 Certicado N ID: 9105022506

est

SR EN ISO 9001:2001 Cert. Nr 6589

UNI EN ISO 9001:2000 Cert. N. 1248/2


Icom Engineering is member of GBC Italia

Commercial and technical office: Via Germania, 8 - Z.I. Camin I - 35127 PADOVA Tel. 0039 0498536811 Fax 0039 0498536888 info@icomengineering.com www.icomengineering.com

ISOPAN S.p.A.
PATRICA headquarters

ISOPAN S.p.A.
TREVENZUOLO branch

S.P. Morolense I - 03010 PATRICA (FR) Tel. (39) 0775 2081 Fax (39) 0775 293177 isopan@isopan.it

Via Giona, 5 I - 37060 TREVENZUOLO (VR) Tel. (39) 045 7359111 Fax (39) 045 7359100 isopan@isopan.it EN ISO 9001 TV Italia S.r.l. certied

ISOPAN IBRICA SL Polgono Industrial de Constant Avda. de les Puntes, parcela 23 E - 43120 CONSTANT (TARRAGONA) Tel. (34) 977524546 Fax (34) 977524597 isopan@isopan.es EN ISO 9001 TV Rheinland certied

ISOPAN EST Sos. de Centura 109 Popesti Leordeni RO - 077160 - jud. ILFOV Tel. (40) 21 3051600 Fax (40) 21 3051610 isopan@isopan.it

DIN EN ISO 9001:2008 Certicado N ID: 9105022506

ISO 9001:2000 Cert. N. 501002347- Rev. 3

ISOPAN FRANCE
Sales ofce

ISOPAN CHILE
Sales ofce

ISOPAN POLSKA
Sales ofce

Avenue du Golf - Parc Innolin - Bat. C2 33700 Mrignac (FRANCE) Tel. (33) 5 56021352 Fax (33) 5 56978786 www.isopan.com

Alcntara 200, piso 6, of. 624 Las Condes - 7550159, SANTIAGO - CHILE Tel. (56) 2 369 5656 www.isopan.cl

Ul. Rakowiecka 34 lok. 5 02-532 WARSZAWA Tel. (48) 22 203 53 95 Fax (48) 22 213 92 53 isopan@isopan.pl www.isopan.pl

Isopan is member of GBC Italia

These technical data and characteristics are not binding. ISOPAN reserves the right to modify this information at any time without prior notice. Any kind of reproduction, even partial, if not authorized, is forbidden, whatever means utilized.

Revisione 10 - GB - Versione Luglio 2011

Copyright by Isopan S.p.A.

Isopan: CE marked sandwich panels

Вам также может понравиться