Академический Документы
Профессиональный Документы
Культура Документы
e. g. Application group 1
e. g. DDA-FC
Option
5 1 4
Low operation costs Longer maintenance intervals Extremely high dosing accuracy
8 1 2 3 4 5
SMART Digital pump Foot valve with 2 level switch Suction hose, PVC*, 2 m Deaeration hose, PE*, 2 m Pressure Valve (only pump type DDA-FC) Discharge hose, PE*, 6 m Injection unit with spring loaded-non return valve Control cables for all input- and output signals, 5 m Option Multifunction valve
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.
1.5
4 5
6 7 8
*Dosing sets in application group 4 (PVDF/T/C) always include ETFE hose For further accessories and more details please see data booklet SMART Digital
GRUNDFOS Holding A/S Poul Due Jensens Vej 7 DK-8850 Bjerringbro Tel: +45 87 50 14 00 www.grundfos.com
GRUNDFOS WATER TREATMENT GmbH Reetzstrae 85 D-76327 Pfinztal Tel: +49 7240 61 0 wt.grundfos.com
GruAl11-001_Broschuere_PumpFinder_120809.indd 1-3
98316643/0812
10.08.2012 17:57:12
Application group
DDA Hose
Control variant:
DDC
DDE
Application Group Max. flow (l/h) 7.5 DDA-FC 17 30 7.5 DDA-AR 17 30 6 DDC-AR 9 15 DDE-P
Chemical formula
AlCl3 Al2(SO4)3 Ca(OH)2 CuSO4 FeCl3 Fe2(SO4)3 FeCl2 FeSO4 HCl H2O2 NaClO3 NaCl NaClO2 Na2S Na2SO3 Na2S2O3 H2SO3 CH3COOH NH4OH KOH KMnO4 NaOH Ca(OCl)2 H2CrO4 HNO3 NaOCI H2SO4 CH3COOH H2SiF6 HNO3 CH3COOOH H2SO4
4
Optional
Pump type Max. pressure (bar) 16 7 4 16 7 4 10 7 4 10 4 16 7 4 16 7 4 10 7 4 10 4 10 7 4 10 7 4 10 7 4 10 4 16 7 4 16 7 4 Hose size (mm) 4/6 9/12 9/12 4/6 9/12 9/12 4/6 9/12 9/12 4/6 9/12 4/6 9/12 9/12 4/6 9/12 9/12 4/6 9/12 9/12 4/6 9/12 4/6 9/12 9/12 4/6 9/12 9/12 4/6 9/12 9/12 4/6 9/12 4/6 9/12 9/12 4/6 9/12 9/12 Dosing Set Part number 97974146 97974151 97974158 97950230 97974133 97974140 97974061 97974066 97974070 97974041 97974045 97974147 97974153 97974159 97974076 97974134 97974141 97974062 97974067 97974071 97974042 97974046 97974148 97974154 97974160 97974077 97974135 97974142 97974063 97974068 97974072 97974043 97974047 97974150 97974157 97974162 97974079 97974138 97974145 Relief pressure 10 bar: 95730812 Relief pressure 16 bar: 95730828 Relief pressure 16 bar: 95730823 Relief pressure 10 bar: 95730807 Relief pressure 16 bar: 95730822 Relief pressure 10 bar: 95704591 Relief pressure 16 bar: 95730821 Relief pressure 10 bar: 95704585 Multifunction valve Part number
Ball
Overview of functions
FC AR AR P
General
Digital Dosing: Internal stroke speed and frequency control Mounting plate (basic / wall mounting)
Control panel
Control cube mountable in three positions: front, left, right Control panel position: front-fitted Transparent protective cover for control elements Capacity setting in millilitres, litres or US-gallons Graphical display with background light in four colours for status indication: white, green, yellow, red Plain-text menu in different languages Turn-and-push knob (click wheel) for easy navigation Capacity adjustment knob (0.1 100 %) Start / Stop key 100 % key (deaeration) Operation mode switch (manual / pulse)
Ferrous chloride Ferrous sulphate Hydrochloric acid Hydrogen peroxide*3 Sodium chlorate Sodium chloride Sodium chlorite Sodium sulphide Sodium sulphite Sodium thiosulfate Sulphurous acid
(PP/V/C)
6 15 7.5
DDA-FC
17 30 7.5
Operation Modes
Manual speed control Pulse control in ml/pulse Pulse control (1:n) Analog control 0/4 20 mA Batch control (pulse-based) Dosing timer cycle Dosing timer week Fieldbus control
2 3 4
Acetic Acid Ammonia, aqueous Potassium hydroxide Potassium permanganate Sodium hydroxide Calcium hypochlorite Chromic acid Nitric acid Sodium hypochlorite*3 Sulphuric acid* Acetic acid Fluosilicic acid Nitric acid Peracetic acid Sulphuric acid *4
(PP/E/C) DDC-AR
DDA-AR
17 30 6 9 15 6 15 7.5
Functions
Auto deaeration also during pump standby FlowControl system with selective fault diagnosis Pressure monitoring (min. / max.) SlowMode (anti-cavitation) Calibration mode Scaling of analog input Service information display Relay setting: alarm, warning, stroke signal, pump dosing, pulse input Relay setting (additionally): timer cycle, timer week
DDE-P
DDA-FC
17 30 7.5
(PVC/V/C) DDC-AR
DDA-AR
17 30 6 9 15 6 15 7.5
Inputs / Outputs
Input for external stop Input for pulse control Input for analog 0/4 20 mA control Input for low-level signal Input for empty tank signal Output relay (2 relays) Output analog 0/4 20 mA Input / Output for GENIbus Input / Output for E-box (e. g. E-box 150 with Profibus DP)
DDE-P
*1 Once the pump is stopped, calcium hydroxide will sediment rapidly *2 Risk of crystallisation *3 Strongly degassing, pump type DDA-FC or -FCM recommended *4 Reacts violently with water and generates much heat. Pump should be absolutely dry before dosing sulphuric acid Note: Some of the liquids in this table may be toxic, corrosive or hazardous. Note: Please be careful when handling these liquids.
(PVDF/T/C) For further control variants and details please see data booklet SMART Digital
DDA-FC
17 30 7.5
DDA-AR
17 30
GruAl11-001_Broschuere_PumpFinder_120809.indd 6
10.08.2012 17:57:26