Specification

SECTION 07500 ROOFING PART 1 GENERAL 1.1 SECTION INCLUDES 1.2 REFERENCES 1.3 SUBMITTALS 1.3.1 PRODUCT DATA 1.3.2 SAMPLES 1.3.3 SHOP DRAWINGS 1.4 TRANSPORTATION, HANDLING AND STORAGE 1.5 WARRANTY 1.6 QUALITY ASSURANCE 1.6.1 MANUFACTURER 1.6.2 INSTALLATION 1.6.3 THERMAL RESISTANCE 1.6.4 FIRE PERFORMANCE CHARACTERISTICS 1.7 JOB CONDITIONS PART 2 - PRODUCTS 2.1 INVERTED ROOFING SYSTEM 2.1.1 ROOF SCREED 2.1.2 BITUMINOUS SHEET MEMBRANE WATERPROOFING 2.1.3 ROOF THERMAL INSULATION 2.1.3.1 CONSTRUCTION 2.1.3.2 RIGID ROOF INSULATION BOARDS 2.1.4 SEPARATION LAYER 2.1.5 PROTECTION LAYER 2.1.6 FLASHING MATERIALS 2.1.7 ROOF TOPPING 2.1.7.1 GRAVEL SURFACING 2.1.7.2 CONCRETE TILES PART 3 - EXECUTION 3.1 GENERAL 3.2 INVERTED ROOFING SYSTEM 3.2.1 PREPARATION OF SUBSTRATE 3.2.2 ROOFING MEMBRANE INSTALLATION 3.2.3 INSULATION INSTALLATION 3.2.4 ROOF TOPPING 3.3 PROTECTION OF ROOFING 07500-2/8 07500-2/8 07500-2/8 07500-3/8 07500-3/8 07500-3/8 07500-3/8 07500-3/8 07500-3/8 07500-4/8 07500-4/8 07500-4/8 07500-4/8 07500-4/8 07500-4/8 07500-4/8 07500-4/8 07500-4/8 07500-5/8 07500-5/8 07500-5/8 07500-5/8 07500-5/8 07500-5/8 07500-5/8 07500-5/8 07500-5/8 07500-5/8 07500-6/8 07500-6/8 07500-6/8 07500-6/8 07500-6/8 07500-7/8 07500-7/8 07500-8/8

ROOFING

07500-1/8

Specification

SECTION 07500 - ROOFING 000000001.PART 1 - GENERAL 1.1 SECTION INCLUDES 1.1.1. Inverted roofing system and the integral accessories related to the system installation as indicated on Drawings and as specified herein. 1.20 REFERENCES 1.2.1. ASTM - American Society for Testing and Materials ASTM C 495 ASTM D 471 ASTM D 570 ASTM D 638 ASTM D 828 ASTM D 1004 ASTM E 84 ASTM E 96 ASTM E 119 ASTM E 136 ASTM E 154 Test Method for Compressive Strength of Lightweight Insulating Concrete Test Method for Rubber Property - Effect of Liquids Test Method for Water Absorption of Plastics Test Method for Tensile Properties of Plastics Test Method for Tensile Breaking Strength of Paper and Paperboard Test Method for Initial Test Resistance of Plastic Film and Sheeting Test Method for Surface Burning Characteristics of Building Materials Test Methods for Water Vapor Transmission of Materials Test Method for Fire Tests of Building Construction and Materials Test Method for Behavior of Materials in a Vertical Tube Furnace at 750oC Test Method for Water Vapor Retarders Used in Contact with Earth under Concrete Slabs, on walls, or as Ground Cover

1.2.2 SASO Saudi Arabian Standards Organization

ROOFING

07500-2/8

Specification

SASO 1335 Thermal Insulation Conditions for Buildings. SASO 1554 Expanded polystyrene insulation boards Part 1: Boards manufactured from expandable beads SASO 1555 - Expanded polystyrene insulation board Part 2: Extruded boards. SASO 1029 - Cement Tiles SASO 1028 - Methods of Test for Cement Tiles. SASO 142 SASO 143 Physical and Mechanical Testing Methods of Portland Cement Portland Cement, Ordinary and Rapid - Hardening

1.3.0 SUBMITTALS 1.3.1. Product Data: Submit specifications, installation instructions, and general recommendations from the roofing materials manufacturer for each type of roofing product required. Include the manufacturer's data substantiating that the materials used are in compliance with the requirements. 1.3.2. Samples: Submit samples of each roofing system material for the Contracting Officer's approval. 1.3.3. Shop Drawings: Submit complete shop drawings showing roof configurations and sheet layout, perimeter details as well as special conditions. 1.40 TRANSPORTATION, HANDLING AND STORAGE 1.4.1. Deliver materials in the manufacturer's unopened, labeled packing, and conform to the manufacturer's storage, handling, installation and protection requirements. 1.50 WARRANTY 1.5.1. Provide a written warranty, signed by the Manufacturer of the primary roofing materials and the Installer, agreeing to replace and repair defective materials and workmanship for a period of 10 years starting from date of substantial completion. 1.6.0 QUALITY ASSURANCE

ROOFING

07500-3/8

Specification

1.6.1.

Manufacturer: Provide primary products for the roofing system produced by a single manufacturer to the greatest possible extent. Provide secondary products which are acceptable to the manufacturer of primary products. Installation: Work under this Section shall be performed by a specialized Sub-Contractor approved by the Contracting Officer, recommended by the waterproofing membrane manufacturer, and having at least 10 years experience in successfully completed projects. Thermal Resistance: Where thermal resistance properties of insulating materials are designated by the R-values they represent the rate of heat flow through a material of thickness indicated, measured by the test method included in the referenced material standard or as otherwise indicated. Fire Performance Characteristics: Provide insulation materials which are identical to those whose fire performance characteristics, as listed for each material or assembly of which insulation is a part, have been determined by testing according to the methods indicated below: 1.6.4.1. Surface Burning Characteristics: ASTM E 84 or equivalent standards. 1.6.4.2. Fire Resistance Ratings: ASTM E 119 or equivalent standards. 1.6.4.3. Combustibility Characteristics: ASTM E 136 or equivalent standards.

1.6.2.

1.6.3.

1.6.4.

1.700 JOB CONDITIONS 1.7.1. Weather: Proceed with roofing work when the existing and forecasted weather conditions permit work to be performed in accordance with the manufacturer's recommendations and warranty requirements. 2.00PART 2 - PRODUCTS 2.1.00 INVERTED ROOFING SYSTEM 2.1.1 Roof Screed: Lightweight concrete with oven dry density of 640 - 800 Kg/m, when tested as per ASTM C 495 and minimum compressive strength 3 MPa, when tested in accordance with ASTM C 495. Foaming agent shall be as recommended by the Manufacturer. Mix design shall be as recommended by the manufacturer and approved by the Contracting Officer. Thickness as recommended by the manufacturer (but not less than 50 mm thick), and shall be applied to roof to maintain the required slope.

ROOFING

07500-4/8

Specification

2.1.2. 2.1.30

Bituminous Sheet Membrane Waterproofing: Refer to Section 07100 - MEMBRANE WATERPROOFING. Roof Thermal Insulation: 2.1.3.1. Construction: Close-celled, extruded polystyrene rigid foam, 80 mm thick, with integral high density skin, conforming to ASTM C 578 or DIN 18164 Part 1; flame spread rating of 25 or less when tested in accordance with ASTM E 84; 5-year aged average thermal conductivity of 0.032 W/mK when tested at 24oC in accordance with ASTM C 518; water vapor permeability of 0.60 perm-inch average; average water absorption of maximum 1 percent by volume; with rebate details on four edges of board. 2.1.3.2. Rigid roof insulation boards: shall have compressive strength of 300 kPa average when tested according to ASTM D 1621 and minimum density 32 kg/m.

2.1.4.0 2.1.5.

Separation Layer: Non-woven polyester fabric of a minimum density of 200 g/m and to be laid above the roof insulation. Protection Layer: High density polyethylene sheeting conforming to ASTM E 154, 250 microns (10 mils) thick. Similar material having a vapor permeance rating not more than 0.3 perm as determined by ASTM E 96, Procedure E will be considered suitable when approved by the Contracting Officer. Flashing Materials: Manufacturer's standard extruded aluminum system compatible with the roofing membrane. Roof Topping: 2.1.7.1 Gravel Surfacing: Where indicated on Drawings, provide round edge pea gravel aggregates with diameter size of 15 - 30 mm, and total thickness of 50 mm only for areas shown on the Drawings. Concrete Tiles: Lay concrete tiles where indicated on Drawings. Size shall be as shown on Drawings.

2.1.6. 2.1.7.

2.1.7.2

3.00PART 3 - EXECUTION 3.1 GENERAL: 3.1.1. Roof waterproofing works shall be executed by a specialized Sub-

ROOFING

07500-5/8

Specification

Contractor recommended by the waterproofing membrane manufacturer and approved by the Contracting Officer. 3.20 INVERTED ROOFING SYSTEM 3.2.1. Preparation of Substrate: 3.2.1.1. After completion and curing of roof screed, inspect condition of substrate to receive roofing system, and conditions under which work will be performed. Correct unsatisfactory conditions including inadequate provisions in substrate for bonding roofing. Do not proceed with roofing work until unsatisfactory conditions have been corrected. Install cant strips, fillets, and accessory items as indicated, or as recommended by the manufacturer even though not shown on Drawings. Clean, prepare, and treat substrate according to manufacturer's written instructions. Provide clean, dust-free, and dry substrate for waterproofing application. Mask off adjoining surfaces not receiving waterproofing to prevent spillage affecting other construction. Remove grease, oil, bitumen, form release agents, paints, and other penetrating contaminants from concrete. Remove fins, ridges, mortar, and other projections and fill honeycomb, aggregate pockets, holes, and other voids. Prepare, fill, prime, and treat joints and cracks in substrate. Remove dust and dirt from joints and cracks according to ASTM D 4258. Prepare, treat, and seal vertical and horizontal surfaces at terminations and penetrations through waterproofing and at drains and protrusions.

3.2.1.2.

3.2.1.3.

3.2.1.4. 3.2.1.5. 3.2.1.6. 3.2.1.7.

3.2.1.8.

3.2.2. 0

Roofing Membrane Installation: Installation details: Perform external and internal corners, upstands, drainage and pipes penetrations strictly in accordance with those shown on the Drawings and as recommended by the manufacturer. Membrane Installation: For Inverted Roofing System: Unroll, align membrane then re-roll and bond to the primed substrate by melting underside of membrane using a torch with gas burner. Lap seams minimum 75 mm, and seal seam with hot

3.2.2.1.

3.2.2.2

ROOFING

07500-6/8

Specification

trowel and excess mastic sealer. Roofing membrane shall be fully bonded to the primed substrate. Start laying of the roofing membrane from the lowest point when laid on a surface to falls to ensure weathered overlaps. 3.2.2.3. 3.2.3. 0 Test roof membrane after completion by flooding 75 mm water height for a period of 48 hours.

Insulation Installation: Comply with insulation manufacturer's written instruction for particular conditions of installation. Lay polyethylene sheet protection layer over waterproofing membrane prior to installation of insulation boards. Extended insulation full thickness over entire area to be insulated. Cut and fit tightly around obstructions and fill voids with insulation. Remove projection interfering with placement. Lay non-woven polyester fabric separation layer over insulation prior to installation of roof topping.

3.2.3.1.

3.2.3.2.

3.2.3.3. 3.2.4.0

Roof Topping: After completing waterproofing membrane, composite flashing and set-on accessories, as well as laying the insulation on each substantial area of roofing, cover the area with the separation layer. Provide one of the following roof toppings as indicated on Drawings and as follows: a. b. Aggregate Surfacing: Loose-fill the surface with a uniform layer of pea gravel 50 mm thick. Concrete Tiles: Lay concrete tiles as per drawings.

3.2.4.1.

3.2.4.2.

3.30

PROTECTION OF ROOFING 3.3.1. Protect roofing upon completion of roofing work and during the remainder of construction period. At the end of construction, or at the time when remaining construction work will in no way affect or endanger the roofing, make a final inspection of roofing and prepare a written report describing the nature and the extent of deterioration or damage found in work.

ROOFING

07500-7/8

Specification

3.3.2. Repair or replace the deteriorated or the defective work found at time of final inspection. Repair or replace the roofing and associated work to a condition free of damage and deterioration at time of substantial completion. END OF SECTION

ROOFING

07500-8/8