Collection of Datasheets
R E F R I G E R AT I O N A N D A I R C O N D I T I O N I N G
T-Series
TL4CL
TL4DL
(LBP/MBP)
(MBP/HBP)
Page 10
Page 12
N-Series
NL7CLX
S-Series
SC10CLX
SC10MLX
SC12CLX.2
SC12MLX
(LBP/MBP)
Page 14
F-Series
FR6CL
FR6DL
FR7.5CL
FR8.5CL
(LBP/MBP)
(MBP/HBP)
(LBP/MBP)
(LBP)
Page
Page
Page
Page
16
18
20
22
Page
Page
Page
Page
Page
Page
Page
Page
24
26
28
30
32
34
36
38
Page
Page
Page
Page
Page
Page
Page
Page
40
42
44
46
48
50
52
54
S-Series
SC10CL
(LBP/MBP)
SC10DL
(MBP/HBP)
SC12CL
(LBP/MBP)
SC12DL
(MBP/HBP)
SC15CL
(LBP/MBP)
SC15DL
(MBP/HBP)
SC18CL
(LBP/MBP)
SC21CL
(LBP)
S-Series (Twins)
SC10/10CL (LBP/MBP)
SC10/10DL (MBP/HBP)
SC12/12CL (LBP/MBP)
SC12/12DL (MBP/HBP)
SC15/15CL (LBP/MBP)
SC15/15DL (MBP/HBP)
SC18/18CL (LBP/MBP)
SC21/21CL (LBP)
Page
Page
Page
Page
66
68
70
72
(LBP/MBP)
(LBP)
Page 74
Page 76
N-Series
NF5.5CLX
NF7CLX
(LBP/MBP)
(LBP/MBP)
Page 78
Page 80
S-Series
SC10CL
SC12CL
SC12CLX.2
SC12MLX
SC15CLX.2
SC15MLX
(LBP/MBP)
(LBP)
(LBP)
(MBP)
(LBP)
(MBP)
Page
Page
Page
Page
Page
Page
82
84
86
88
90
92
(LBP/MBP)
(MBP)
(LBP)
(MBP)
Page 56
Page 58
Page 94
Page 96
Page 98
Page 100
Page 102
Page 104
Page 60
Page 62
Page 64
CK.54.B6.02
September 2002
1. General
This collection of datasheets contains information on Danfoss hermetic refrigeration compressors for 220-240V and 115V especially designed for refrigeration systems using
refrigerant R404A (CHF2CF3 / CH3CF3 / CH2FCF3) / R507 (CHF2CF3 / CH3CF3) and R407C
(CH2F2 / CHF2CF3 / CH2FCF3).
The programme consists of the basic types TL, TF, NL, NF, FR, SC and SC Twin.
8238-3
8238-5
8238-4
TL (TF similar)
NL (NF similar)
FR
8238-6
8238-7
SC
1.1 Compressor
designations
SC Twin
Optimization
level
Compressor
size
Application
range
Start
Generation
characteristics
TL, TF
CL
R404/R507 LBP
(MBP)
Blank
Standard
energy level
NL, NF
FR
Nominal
displacement
in cm3
S
Semi-direct intake
DL
R404/R507 HBP
R407C HBP
Blank
universal
(principal rule)
Blank
First
generation
.2
X = HST
Second
characteristics generation
ML
(capillary tube)
R404/R507 MBP
etc.
SC
Examples
TF
September 2002
4.5
CL
NL
CL
FR
DL
SC
15
CL
CK.54.B6.02
.2
3
1.2 Design
All Danfoss compressors for R404A/R507 and R407C from the TL, TF, NL, NF, FR, and SC
range are standard efficiency types.
Compressors for 220-240V have a yellow label with the type designation. This label has a
lilac stripe and the text R404A R507 or R404A R407C R507.
Compressors for 115V have a green label with the type designation. This label has a lilac
stripe and the text R404A R507.
SC10DL
104L
R404A
R407CR507
Approvals
Barcode on
white background
115V~60Hz
MBP HST
R404A
R507
Lilac stripe
2525
DANFOSS COMPRESSORS
Yellow background
8306-2
Lilac stripe
104L
SC12MLX
Application
220-240V~50Hz
MBP/HBP HST
Barcode on
white background
1606
DANFOSS COMPRESSORS
8315-10
Application
Green background
The country of origin indicated on the compressor paper label and on the compressor cover
varies depending on the manufacturing place. Information can be found on our technical
information sheet Country of Origin.
1.4 Data stamping
The compressor type and production date are stamped on the side of the compressor. The
information may be as follows,
L-4CL-2071
F-202E2207
The first line states the model designation and the code no.
L= last letter (or last two letters) of the compressor type
4CL
= nominal displacement and application
2071
= 4 last digits in the code no.
(= position mark)
The second line states the date of manufacture and internal Danfoss codes.
F
= manufacturing place (F = Germany, AL = Slovenia, AM = Mexico)
20
= week 20
2
= 2002
E
= Friday (A = Monday etc.)
220
= nominal voltage
7
= internal Danfoss code
1.5 Compressor
dimensions
The build-in conditions (total height, weight, tube dimensions etc.) are specified in the
individual datasheets including dimensioned sketches for the compressors.
2. Application range CL
Compressors with denominations ending with CL are primarily designed for low evaporating
temperatures (LBP Low Back Pressure) for use in commercial refrigerators, freezers and
similar applications in regions with normal supply voltage.
ML
Compressors with denominations ending with ML are primarily designed for medium evaporation temperatures (MBP Medium Back Pressure) for use in commercial refrigerators,
bottle coolers, ice machines and similar applications.
DL
Compressors with denominations ending with DL are primarily designed for high evaporation temperatures (HBP High Back Pressure) for use in commercial refrigerators, liquid
coolers, dehumidifiers, refrigerated display counters, vending machines, heat pumps, and
similar applications.
The following table shows the normally recommended applications as regards voltage/
frequency, ambient temperature, evaporating temperature and necessary compressor cooling.
The recommendations must be regarded as a guideline only as they presuppose a proper
dimensioning of the refrigeration system.
CK.54.B6.02
September 2002
Compressor
Mains [V/Hz]
32C
Ambient temperature
38C
43C
TL4CL
TL4DL
NL7CLX
FR6 - 7.5CL
FR8.5CL
FR6DL
R404A/R507, SC10 - 12 - 15 - 18CL
220-240V 50Hz
SC21CL
SC10 - 12 - 15DL
SC10/10 - 12/12CL
SC15/15CL - 18/18CL
SC21/21CL
SC10/10 - 12/12 - 15/15DL
SC12 - 15CLX
R404A/R507,
SC10/10CLX
220-240V 60Hz
SC12/12 - 15/15CLX
SC10CLX
R404A/R507,
SC12CLX.2
220-240V 50/60Hz
SC10 - 12MLX
TF4CLX
TFS4.5CLX
NF5.5CLX
R404A/R507,
115V 60Hz
NF7CLX
SC10CL
SC12CL
SC15CLX.2
SC12MLX
SC15MLX
SC10 - 12 - 15DL
R407C,
220-240V 50Hz SC10/10 - 12/12 - 15/15DL
S
O
F1
F2
*
**
=
=
=
=
=
=
=
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F1
F1
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F1
F1
F1
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F1
F1
F1
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F1
F2
F2
F2
F2
F2
F2
F2
F2
The application limits regarding evaporating temperatures and motor systems are specified in the individual
compressor datasheets.
Condensing temperature
Winding temperature
September 2002
In order to secure a satisfying lifetime of the compressor, and to protect the compressor
against overload, some design criteria for the appliances must be fulfilled.
Both the condensing temperature and the compressor temperature should be kept as low
as possible. This can be done by using well-dimensioned condenser surfaces and by ensuring
good ventilation around the compressor under all operating conditions.
In order to protect the compressor against overload, the compressor has to start and work
properly through pressure peaks obtained in the highest ambient temperature and lowest
working voltage. At peak load the condensing temperature must not exceed 60C. The
winding temperature must not exceed 135C.
At stable operation conditions the condensing temperature must not exceed 50C. The
winding temperature must not exceed 125C.
These limitations ensure a protection of valves, gaskets, oil, and motor insulation.
CK.54.B6.02
3. Electrical equipment
The compressors are equipped with a single-phase AC motor. All compressors for R404A/
R507 and R407C are designed only for use with High Starting Torque (HST).
The electrical equipments are classified as normal tight (IP20).
The motor protector is built into the motor (winding protector). Exception are compressors
with the denominations TF and NF and some SCs.
Earth connections are located on the bracket around the current lead-in of the compressor.
No attempt must be made to start the compressor without a complete starting device.
The compressors can be supplied with the following motor systems:
8076
8077-2
TL, NL, FR
TF, NF
8088
8467
Compressors with the motor type Capacitor Start Induction Run (CSIR) have a starting
device for High Starting Torque (HST). This starting device consists of a starting relay and
a starting capacitor and is used for compressors with the denominations TL, TF, NL, NF, FR
and SC. The following designs of starting devices exist:
a) Relay + starting capacitor + cord relief + cover, used for compressors with the denominations TL, NL, FR and SC.
b) Relay housing including motor protector + starting capacitor + cord relief (2x) + cover,
used for compressors with the denomination TF and NF.
c) Relay + starting capacitor (with bracket) + cover/protector/protector holder (parts of
compressor), used for compressors with the denomination SC which have an external
protector.
The starting device requires no pressure-equalization before each start and is normally
used in refrigerating systems with expansion valve as throttling device or in capillary tube
systems where pressure equalizing is not obtained during the standstill periods.
The starting capacitor is designed for short time cut-in. 1.7% ED, which is stamped on
the starting capacitor, means for instance max. 10 cutins per hour each with a duration of
6 seconds (normally shorter than 1 sec.).
SC
SC (external protector)
CK.54.B6.02
September 2002
8191
8467-2
SC
SC (external protector)
Compressors with the motor type Capacitor Start Run (CSR) have a starting device for
High Starting Torque (HST). The following designs of starting devices exist:
a) Relay + starting capacitor + run capacitor + terminal board + cord relief + cover, used for
compressors with the denomination SC.
b) Relay + starting capacitor (with bracket) run capacitor + cover/protector/protector holder
(parts of compressor), used for compressors with the denomination SC which have an
external protector.
The starting device is mandatory for some of the biggest SC compressors. The starting capacitor is designed for short time cut-in. 1.7% ED, which is stamped on the starting capacitor, means for instance max. 10 cut-ins per hour each with a duration of 6 seconds.
For further information on which starting device to use on individual compressors, please
refer to the actual datasheets (some compressors have limitations for either LST or HST).
3.6 Connections
The electrical equipments are equipped with connectors depending on the ordered code
number,
Starting relays: 6.3 mm spade connectors only
The power supply must be connected as shown in the wiring diagrams for the chosen
electrical equipment given in the actual datasheets.
3.7 Approvals
R
THERMALLY
PROTECTED
Approval mark
September 2002
8459-4
SC12MLX
115V-60Hz
1PH
CK.54.B6.02
4. Moisture and
Impurities
5. Max. refrigerant
charge
The refrigerant charge must never be too large to be contained on the condenser side of the
refrigeration system. Only the refrigerant amount which is necessary for the system to
function must be charged.
The refrigerant amount may be critical as regards oil foaming and liquid hammer after long
standstill periods. Because of this, limitations of refrigerant charges have been introduced.
The maximum refrigerant charge is specified in the individual datasheets.
If these limitations cannot be complied with, the risk may be reduced if a crankcase heater
is properly used or if a pump down system is established.
6. Oil charge
The compressors are supplied charged with dried and degassed oil, which is normally
sufficient for the lifetime of the compressor. The refrigeration systems and the system
components must be dimensioned in such a way that the oil can be lead back continuously
to the compressor housing without accumulating in the system, e.g. without oil pockets
and with sufficient gas velocity. The compressors use polyolester oils and are approved
only for these oils and R404A/R507 respectively R407C.
The oil charge is specified in the individual datasheets.
7. Mounting
Soldering problems caused by oil in the connectors can be avoided by placing the compressor on its baseplate some time before soldering it into the system. The compressor
must never be placed upside down when mounting the rubber grommets in the baseplate.
Instead place the compressor on its side with the connectors upwards.
7.1 Mounting
accessories
Washer
Nut M6
Washer
Grommet sleeve
Steel pin
Compressor base
Clip
Compressor base
3327-2
7382-2
Cabinet base
Cabinet base
Screw M6 x 25
Rubber grommet
Rubber grommet
Bolt joint
Snap-on joint
The mounting accessories for the compressors are available in two versions, with bolt joint
or snap-on joint. The code numbers for the mounting accessories are specified in the individual compressor datasheets.
These rubber grommets are designed for the 16 mm holes of the baseplate:
Bolt joint for one compressor in a bag
118-1917 or 118-1946
Bolt joint in quantities
118-1918 or 118-1945
Snap-on in quantities
118-1919 or 118-1944
Snap-on for one compressor in a bag
118-1947
These rubber grommets are designed for the 19 mm holes of the baseplate:
Bolt joint in quantities
118-1948
CK.54.B6.02
September 2002
8. Condition at delivery
The compressors are delivered without mounted starting devices on pallets with the dimensions 1144 x 800 mm. Quantities per pallets are specified in the individual datasheets.
Electrical equipment is packed in separate boxes.
The most important performance controls carried out during manufacturing are,
A high potential insulation test with 1650V for 1 second
Pumping capacity
Tightness of discharge side and discharge valve
Tightness of compressor housing
Check of the right oil charge
Noise test
The compressors are supplied with sealed connectors and the sealing should not be removed before the system assembly takes place (max. 15 minutes with open connectors).
9. Twin compressors
The Twin version consists of two SC compressors mounted on a common baseplate. The
two compressors are joined by an oil-equalizing tube and also have an intake manifold with
screw connector for a service valve or a solder connector (these parts are supplied as
accessories).
Each Twin compressor has to be ordered with two sets of electrical equipment and mounting
accessories. To ensure optimum starting characteristics and the smallest possible mains
load we recommend that the compressors be equipped with a time-delay relay for start of
the second compressor.
Twin compressors can operate with capacity regulation depending on the controls used.
Normally, the same system components can be used as were used with R502. However, an
adjustment of the charge has to be made.
A drier with 3 desiccant of Molecular Sieves or a hard core drier compatible with R404A
must always be used.
Rules for dryness and cleanliness of system components (DIN 8964) are transferred to
R404A systems.
The system components must not contain mineral oil or greasy substances.
The compressors must be soldered into the system no later than 15 minutes after the
connector seals have been removed.
The same evacuation procedure as for R502/R22 systems must be used.
Max. 1% non-condensable gases.
The system must not contain any chlorine.
The charging equipment must only be used for R404A/R507 respectively R407C.
11. Warnings
September 2002
No high potential test nor start tests must be carried out while the compressor is under
vacuum.
No attempt must be made to start the compressor without a complete starting device.
Allow the compressor to assume a temperature above 10C before starting the first time in
order to avoid starting problems.
Anti-freeze agents must not be used in the compressors as such agents are damaging to
several of the materials used. In particular, the ethyl or methyl alcohol contents of such
anti-freeze agents have a destructive effect on the synthetic motor insulation.
CK.54.B6.02
TL4CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.52.A1.02)
General
TL4CL
Code number
102U2071
102U
TL4CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP/MBP
Barcode on
white background
-45 to -5
Yellow background
2071
8294
Compressor
DANFOSS COMPRESSORS
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
280
600
cm3
1690
kg
7.6
3.86
16
Motor size
watt
140
5.7
5.7
14.8/14.5
Dimensions
Height
mm
173
169
location/I.D. mm
6.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
5.0 +0.12/+0.20
170
178
186
204
C or
D
pcs.
105
105
107
A B
Compressors on a pallet
D
C
or
222
176
31.5
28
Suction connector
EN 60335-2-34
30
Approvals
35
70
100
Motor
125
102
September 2002
10
CF.52.A2.02
CK.54.B6.02
71
29
51 20
45
157
60.5
66
8263
96
117
September 2002
-45
52
-40
65
-35
84
-30
110
watt
-25
142
-23.3
155
-20
182
-15
230
-10
286
-5
352
c
Capacity (ASHRAE)
Comp.\C
TL4CL
-45
60
-40
76
watt
-35
98
-30
128
-25
166
-23.3
180
-20
212
-15
268
-10
334
-5
411
b
Power consumption
Comp.\C
TL4CL
-45
81
-40
91
8219
watt
-35
105
-30
121
-25
140
-23.3
147
-20
160
-15
179
-10
198
-5
215
a2
d
Current consumption
Comp.\C
TL4CL
-45
0.89
-40
0.79
A
-35
0.80
-30
0.88
-25
1.01
-23.3
1.05
-20
1.14
-15
1.25
-10
1.28
-5
1.31
c
11
10
-45
0.64
W/W
-40
0.72
-35
0.81
-30
0.90
-25
1.02
-23.3
1.06
-20
1.14
-15
1.28
-10
1.45
-40
0.83
-35
0.94
-30
1.05
-25
1.18
-23.3
1.23
-20
1.33
-15
1.50
-10
1.69
COP (ASHRAE)
Comp.\C
TL4CL
-45
0.74
-5
1.64
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
-5
1.92
Main winding
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
TL4CL
Starting relay
a2
117U6000
Cover
103N2010
Starting capacitor 60 F
117U5014
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.52.A2.02
CK.54.B6.02
September 2002
11
TL4DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.52.B1.02)
General
TL4DL
Code number
102U2038
102U
TL4DL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
MBP/HBP
Barcode on
white background
-20 to 10
Yellow background
2038
8298
Compressor
DANFOSS COMPRESSORS
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
280
600
cm3
1690
kg
7.5
3.86
16
Motor size
watt
175
7.5
7.5
12.0/20.0
Dimensions
Height
mm
173
169
location/I.D. mm
6.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
5.0 +0.12/+0.20
170
178
186
204
C or
D
pcs.
105
105
107
A B
Compressors on a pallet
D
C
or
222
176
31.5
28
Suction connector
EN 60335-2-34
30
Approvals
35
70
100
Motor
125
102
September 2002
12
CF.52.B2.02
CK.54.B6.02
71
29
51 20
45
157
60.5
66
8263
96
117
September 2002
-20
196
-15
229
-10
281
watt
-5
349
0
432
5
527
7.2
572
10
631
c
Capacity (ASHRAE)
Comp.\C
TL4DL
-20
229
-15
267
watt
-10
328
-5
409
0
506
5
619
7.2
672
10
742
b
Power consumption
Comp.\C
TL4DL
-20
169
-15
186
watt
-10
203
-5
221
0
239
5
256
7.2
263
8219
10
272
a2
d
Current consumption
Comp.\C
TL4DL
-20
1.22
-15
1.28
A
-10
1.34
-5
1.41
0
1.47
5
1.54
7.2
1.56
10
1.60
c
11
10
-20
1.16
W/W
-15
1.23
-10
1.38
-5
1.58
0
1.81
5
2.06
7.2
2.17
-15
1.44
-10
1.61
-5
1.85
0
2.12
5
2.42
7.2
2.55
COP (ASHRAE)
Comp.\C
TL4DL
-20
1.36
10
2.32
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
10
2.73
Main winding
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
TL4DL
Starting relay
a2
117U6001
Cover
103N2010
Starting capacitor 60 F
117U5014
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.52.B2.02
CK.54.B6.02
September 2002
13
NL7CLX
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet
General
NL7CLX
Code number
105F3710
105F
NL7CLX
Application
R134a
Blue stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP/MBP
Barcode on
white background
-45 to -5
Yellow background
3710
DANFOSS COMPRESSORS
8466
Compressor
Motor type
CSIR
43
32C
F1
38C
F1
43C
F2
Displacement
cm3
7.27
Oil quantity
cm3
320
400
2310
kg
10.4
S
O
F1
F2
Design
cm
204
170
Motor size
watt
235
10.4
100
70
Motor
10.4
16
178
8.2/14.7
Approvals
EN 60335-2-34
205
E
C
8.2 0.09
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
254
80
8248
51
72
166
Compressors on a pallet
102.5
location/I.D. mm
113
September 2002
14
CF.53.I1.02
CK.54.B6.02
75.5
location/I.D. mm
Process connector
27
47
54
78
Suction connector
A B
93.5
203
197
15
A
B
60.5
mm
35
Height
25
Dimensions
119
127
September 2002
-45
-40
-35
watt
-30
-25
328
-23.3
360
-20
-15
-10
-5
c
Capacity (ASHRAE)
Comp.\C
NL7CLX
-45
-40
watt
-35
-30
-25
380
-23.3
419
-20
-15
-10
-5
b
Power consumption
Comp.\C
NL7CLX
-45
-40
watt
-35
-30
-25
276
-23.3
289
-20
-15
-10
8219
-5
a2
d
Current consumption
Comp.\C
NL7CLX
-45
-40
A
-35
-30
-25
1.64
-23.3
1.68
-20
-15
-10
-5
c
11
10
-45
-40
-35
W/W
-30
-25
1.18
-23.3
1.24
-20
-25
1.37
-23.3
1.44
-20
-15
-10
-45
12
13
14
COP (ASHRAE)
Comp.\C
NL7CLX
-5
W/W
-40
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz,
preliminary data
-35
-30
EN 12900/CECOMAF
45C
32C
45C
-15
-10
-5
Main winding
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
NL7CLX
Starting relay
a2
117U6002
103N2010
Cover
Starting capacitor 80 F
117U5015
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.53.I1.02
CK.54.B6.02
September 2002
15
FR6CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.53.A1.02)
General
FR6CL
Code number
103U2670
103U
FR6CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP/MBP
Barcode on
white background
-45 to -5
Yellow background
2670
8295
Compressor
DANFOSS COMPRESSORS
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
450
850
cm3
1350
kg
10.5
6.23
204
178
16
19
215
8.2
8.2
8.9/12.0
Approvals
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
A B
102
130
191
location/I.D. mm
30
B
Suction connector
C
E
196
25
30
mm
Compressors on a pallet
127
165
170
186
200
127
Height
9.7
EN 60335-2-34
Dimensions
35
127
150
watt
80
122.5
September 2002
16
CF.53.A2.02
CK.54.B6.02
8253
24
40
40
55
156
243
32
55
Motor size
101.6
70
60.5
Motor
124.5
127.5
September 2002
-45
77
-40
108
-35
145
-30
189
watt
-25
243
-23.3
263
-20
307
-15
383
-10
473
-5
578
c
Capacity (ASHRAE)
Comp.\C
FR6CL
-45
90
-40
125
watt
-35
168
-30
220
-25
283
-23.3
307
-20
358
-15
447
-10
553
-5
676
b
Power consumption
Comp.\C
FR6CL
-45
126
-40
152
watt
-35
180
-30
210
-25
242
-23.3
253
-20
276
-15
313
-10
353
8219
-5
395
a2
d
Current consumption
Comp.\C
FR6CL
-45
1.13
-40
1.18
A
-35
1.26
-30
1.35
-25
1.46
-23.3
1.51
-20
1.60
-15
1.75
-10
1.91
-5
2.09
c
11
10
-45
0.61
W/W
-40
0.71
-35
0.80
-30
0.90
-25
1.00
-23.3
1.04
-20
1.11
-15
1.22
-10
1.34
-40
0.82
-35
0.94
-30
1.05
-25
1.17
-23.3
1.21
-20
1.29
-15
1.43
-10
1.57
COP (ASHRAE)
Comp.\C
FR6CL
-45
0.71
-5
1.47
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
-5
1.71
Main winding
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
FR6CL
Starting relay
a2
117U6015
103N2010
Cover
Starting capacitor 80 F
117U5015
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.53.A2.02
CK.54.B6.02
September 2002
17
FR6DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.53.C1.02)
General
FR6DL
Code number
103U2680
103U
FR6DL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
MBP/HBP
Barcode on
white background
-20 to 15
Yellow background
2680
8299
Compressor
DANFOSS COMPRESSORS
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
450
850
cm3
1350
kg
10.5
6.23
204
178
16
19
watt
275
10.0
10.0
7.3/12.0
Approvals
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
A B
102
130
191
location/I.D. mm
30
B
Suction connector
C
E
196
25
30
mm
Compressors on a pallet
127
165
170
186
200
127
Height
9.7
EN 60335-2-34
Dimensions
35
127
150
80
122.5
September 2002
18
CF.53.C2.02
CK.54.B6.02
8253
24
40
40
55
156
243
32
55
Motor size
101.6
70
60.5
Motor
124.5
127.5
September 2002
-20
317
-15
385
-10
471
watt
-5
576
0
698
5
840
7.2
907
10
999
15
1177
c
Capacity (ASHRAE)
Comp.\C
FR6DL
-20
370
-15
449
watt
-10
550
-5
673
0
818
5
986
7.2
1065
10
1176
15
1389
b
Power consumption
Comp.\C
FR6DL
-20
290
-15
321
watt
-10
354
-5
388
0
423
5
456
7.2
469
10
485
8219
15
509
a2
d
Current consumption
Comp.\C
FR6DL
-20
1.91
-15
1.99
A
-10
2.10
-5
2.23
0
2.37
5
2.51
7.2
2.56
10
2.62
15
2.70
c
11
10
-20
1.09
W/W
-15
1.20
-10
1.33
-5
1.48
0
1.65
5
1.84
7.2
1.93
10
2.06
-15
1.40
-10
1.56
-5
1.73
0
1.94
5
2.16
7.2
2.27
10
2.42
COP (ASHRAE)
Comp.\C
FR6DL
-20
1.27
15
2.31
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
15
2.73
Main winding
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
FR6DL
Starting relay
a2
117U6010
103N2010
Cover
Starting capacitor 80 F
117U5015
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.53.C2.02
CK.54.B6.02
September 2002
19
FR7.5CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.53.D1.02)
General
FR7.5CL
Code number
103U2790
103U
FR7.5CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP/MBP
Barcode on
white background
-45 to -5
Yellow background
2790
8295-3
Compressor
DANFOSS COMPRESSORS
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
450
850
cm3
1350
kg
10.6
6.93
204
178
16
19
235
9.1
9.1
8.8/12.0
Approvals
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
A B
102
130
191
location/I.D. mm
30
B
Suction connector
C
E
196
25
30
mm
Compressors on a pallet
127
165
170
186
200
127
Height
9.7
EN 60335-2-34
Dimensions
35
127
150
watt
80
122.5
September 2002
20
CF.53.D2.02
CK.54.B6.02
8253
24
40
40
55
156
243
32
55
Motor size
101.6
70
60.5
Motor
124.5
127.5
September 2002
-45
86
-40
114
-35
154
watt
-30
202
-25
262
-23.3
285
-20
333
-15
418
-10
515
-5
630
c
Capacity (ASHRAE)
Comp.\C
FR7.5CL
-45
101
-40
132
watt
-35
178
-30
235
-25
305
-23.3
333
-20
388
-15
488
-10
602
-5
737
b
Power consumption
Comp.\C
FR7.5CL
-45
142
-40
168
watt
-35
197
-30
231
-25
267
-23.3
280
-20
307
-15
349
-10
395
8219
-5
440
a2
d
Current consumption
Comp.\C
FR7.5CL
-45
1.39
-40
1.44
A
-35
1.52
-30
1.62
-25
1.75
-23.3
1.81
-20
1.91
-15
2.09
-10
2.28
-5
2.51
c
11
10
-45
0.61
W/W
-40
0.68
-35
0.78
-30
0.88
-25
0.98
-23.3
1.02
-20
1.09
-15
1.20
-10
1.30
-40
0.79
-35
0.90
-30
1.02
-25
1.14
-23.3
1.19
-20
1.27
-15
1.40
-10
1.53
COP (ASHRAE)
Comp.\C
FR7.5CL
-45
0.71
-5
1.43
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz,
preliminary data
EN 12900/CECOMAF
45C
32C
45C
-5
1.67
Main winding
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
FR7.5CL
Starting relay
a2
117U6016
103N2010
Cover
Starting capacitor 80 F
117U5015
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.53.D2.02
CK.54.B6.02
September 2002
21
FR8.5CL
LBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.53.B1.02)
General
FR8.5CL
Code number
103U2890
103U
FR8.5CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP
Barcode on
white background
-45 to -10
Yellow background
2890
8295-2
Compressor
DANFOSS COMPRESSORS
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
450
850
cm3
1350
kg
10.6
7.95
204
178
16
19
watt
275
10.0
10.0
7.3/12.0
Approvals
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
A B
102
130
191
location/I.D. mm
30
B
Suction connector
C
E
196
25
30
mm
Compressors on a pallet
127
165
170
186
200
127
Height
9.7
EN 60335-2-34
Dimensions
35
127
150
80
122.5
September 2002
22
CF.53.B2.02
CK.54.B6.02
8253
24
40
40
55
156
243
32
55
Motor size
101.6
70
60.5
Motor
124.5
127.5
September 2002
-45
99
-40
126
-35
168
watt
-30
222
-25
290
-23.3
317
-20
372
-15
468
-10
577
c
Capacity (ASHRAE)
Comp.\C
FR8.5CL
-45
115
-40
147
watt
-35
195
-30
259
-25
338
-23.3
369
-20
434
-15
546
-10
674
b
Power consumption
Comp.\C
FR8.5CL
-45
171
-40
198
watt
-35
231
-30
271
-25
315
-23.3
331
-20
364
-15
417
8219
-10
472
a2
d
Current consumption
Comp.\C
FR8.5CL
-45
1.61
-40
1.64
A
-35
1.72
-30
1.83
-25
1.97
-23.3
2.03
-20
2.15
-15
2.35
-10
2.57
c
11
10
-45
0.58
W/W
-40
0.64
-35
0.72
-30
0.82
-25
0.92
-23.3
0.96
-20
1.02
-15
1.12
-40
0.74
-35
0.84
-30
0.96
-25
1.07
-23.3
1.11
-20
1.19
-15
1.31
COP (ASHRAE)
Comp.\C
FR8.5CL
-45
0.67
-10
1.22
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
-10
1.43
Main winding
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
FR8.5CL
Starting relay
a2
117U6010
103N2010
Cover
Starting capacitor 80 F
117U5015
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.53.B2.02
CK.54.B6.02
September 2002
23
SC10CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.A1.02)
General
SC10CL
Code number
104L2523
104L
SC10CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP/MBP
Barcode on
white background
-35 to -5
Yellow background
2523
DANFOSS COMPRESSORS
8296
Compressor
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
550
1300
cm3
1460
kg
13.1
204
178
170
16
watt
315
12.6
12.6
6.7/11.8
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
209
203
B1
183
B2
100
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
August 2002
24
CF.54.A2.02
CK.54.B6.02
107
115
55
63
10.29
8258
September 2002
-35
168
-30
258
-25
365
watt
-23.3
405
-20
489
-15
634
-10
800
-5
991
c
Capacity (ASHRAE)
Comp.\C
SC10CL
-35
195
-30
300
watt
-25
424
-23.3
470
-20
569
-15
737
-10
932
-5
1154
b
8222
Power consumption
Comp.\C
SC10CL
-35
243
-30
294
watt
-25
350
-23.3
370
-20
410
-15
471
-10
530
-5
584
a2
d
Current consumption
Comp.\C
SC10CL
-35
1.91
-30
2.05
A
-25
2.22
-23.3
2.27
-20
2.39
-15
2.59
-10
2.81
-5
3.04
c
11
10
-35
0.69
W/W
-30
0.88
-25
1.04
-23.3
1.09
-20
1.19
-15
1.35
-10
1.51
-30
1.02
-25
1.21
-23.3
1.27
-20
1.39
-15
1.57
-10
1.76
COP (ASHRAE)
Comp.\C
SC10CL
-35
0.80
-5
1.70
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
-5
1.98
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC10CL
Starting relay
a2
117U6003
Cover
103N2009
Starting capacitor 80 F
117U5017
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.A2.02
CK.54.B6.02
August 2002
25
SC10DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.K2.02)
General
SC10DL
Code number
104L2525
104L
SC10DL
Application
R404A
R407C R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
MBP/HBP
Barcode on
white background
-20 to 15
Yellow background
2525
DANFOSS COMPRESSORS
8306
Compressor
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
600
1300
cm3
1410
kg
13.1
204
178
170
16
watt
385
14.8
14.8
5.0/13.7
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
209
203
B1
183
B2
100
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
August 2002
26
CF.54.K3.02
CK.54.B6.02
107
115
55
63
10.29
8258
September 2002
-20
471
-15
611
-10
775
watt
-5
968
0
1192
5
1450
7.2
1576
10
1747
15
2085
c
Capacity (ASHRAE)
Comp.\C
SC10DL
-20
547
-15
710
watt
-10
902
-5
1128
0
1391
5
1696
7.2
1845
10
2048
15
2451
b
8222
Power consumption
Comp.\C
SC10DL
-20
373
-15
429
watt
-10
479
-5
522
0
559
5
590
7.2
601
10
614
15
631
a2
d
Current consumption
Comp.\C
SC10DL
-20
2.55
-15
2.78
A
-10
2.97
-5
3.15
0
3.30
5
3.42
7.2
3.47
10
3.53
15
3.61
c
11
10
-20
1.26
W/W
-15
1.42
-10
1.62
-5
1.85
0
2.13
5
2.46
7.2
2.62
10
2.85
-15
1.66
-10
1.89
-5
2.16
0
2.49
5
2.88
7.2
3.07
10
3.34
COP (ASHRAE)
Comp.\C
SC10DL
-20
1.47
15
3.30
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
15
3.88
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC10DL
Starting relay
a2
117U6005
Cover
103N2009
Starting capacitor 80 F
117U5017
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.K3.02
CK.54.B6.02
August 2002
27
SC12CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.B1.02)
General
SC12CL
Code number
104L2623
104L
SC12CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP/MBP
Barcode on
white background
-45 to -5
Yellow background
2623
DANFOSS COMPRESSORS
8296-4
Compressor
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
550
1300
cm3
1460
kg
12.5
204
178
170
16
watt
385
14.8
14.8
5.0/13.7
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
209
203
B1
183
B2
100
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
August 2002
28
CF.54.B2.02
CK.54.B6.02
107
115
55
63
12.87
8258
September 2002
-45
58
-40
140
-35
237
watt
-30
353
-25
490
-23.3
541
-20
650
-15
835
-10
1048
-5
1292
c
Capacity (ASHRAE)
Comp.\C
SC12CL
-45
67
-40
162
watt
-35
275
-30
410
-25
568
-23.3
629
-20
754
-15
971
-10
1220
-5
1505
b
8222
Power consumption
Comp.\C
SC12CL
-45
190
-40
253
watt
-35
316
-30
380
-25
445
-23.3
468
-20
512
-15
581
-10
654
-5
730
-35
2.43
-30
2.61
-25
2.82
-23.3
2.90
-20
3.06
-15
3.34
-10
3.64
-5
3.97
-30
0.93
-25
1.10
-23.3
1.16
-20
1.27
-15
1.44
-10
1.60
Current consumption
Comp.\C
SC12CL
-45
2.15
-40
2.27
-45
0.30
-40
0.55
-35
0.75
-45
0.35
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-35
0.87
-30
1.08
-25
1.28
EN 12900/CECOMAF
45C
32C
45C
-23.3
1.34
-20
1.47
-15
1.67
-10
1.87
12
-5
2.06
13
14
-5
1.77
W/W
-40
0.64
c
11
10
W/W
COP (ASHRAE)
Comp.\C
SC12CL
a2
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC12CL
Starting relay
a2
117U6005
Cover
103N2009
Starting capacitor 80 F
117U5017
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.B2.02
CK.54.B6.02
August 2002
29
SC12DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.L2.02)
General
SC12DL
Code number
104L2625
104L
SC12DL
Application
R404A
R407C R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
MBP/HBP
Barcode on
white background
-20 to 15
Yellow background
2625
DANFOSS COMPRESSORS
8306-3
Compressor
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
600
1300
cm3
1460
kg
13.6
204
178
170
16
watt
495
18.6
18.6
3.7/14.1
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
219
213
B1
193
B2
110
10.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
August 2002
30
CF.54.L3.02
CK.54.B6.02
107
115
55
63
12.87
8258
September 2002
-20
609
-15
806
-10
1028
watt
-5
1279
0
1565
5
1890
7.2
2046
10
2258
15
2674
c
Capacity (ASHRAE)
Comp.\C
SC12DL
-20
707
-15
937
watt
-10
1196
-5
1491
0
1827
5
2210
7.2
2396
10
2647
15
3144
b
8222
Power consumption
Comp.\C
SC12DL
-20
489
-15
563
watt
-10
624
-5
675
0
717
5
750
7.2
763
10
778
15
800
a2
d
Current consumption
Comp.\C
SC12DL
-20
3.37
-15
3.65
A
-10
3.89
-5
4.11
0
4.29
5
4.44
7.2
4.50
10
4.56
15
4.66
c
11
10
-20
1.24
W/W
-15
1.43
-10
1.65
-5
1.90
0
2.18
5
2.52
7.2
2.68
10
2.90
-15
1.67
-10
1.92
-5
2.21
0
2.55
5
2.95
7.2
3.14
10
3.40
COP (ASHRAE)
Comp.\C
SC12DL
-20
1.45
15
3.34
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
15
3.93
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC12DL
Starting relay
a2
117U6019
Cover
103N2009
Starting capacitor 80 F
117U5017
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.L3.02
CK.54.B6.02
August 2002
31
SC15CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.C1.02)
General
SC15CL
Code number
104L2853
104L
SC15CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP/MBP
Barcode on
white background
-40 to -5
Yellow background
2853
DANFOSS COMPRESSORS
8296-5
Compressor
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
550
1300
cm3
1510
kg
13.8
204
178
170
16
watt
495
18.6
18.6
3.7/14.1
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
219
213
B1
193
B2
110
10.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
August 2002
32
CF.54.C2.02
CK.54.B6.02
107
115
55
63
15.28
8258
September 2002
-40
151
-35
299
-30
452
watt
-25
615
-23.3
673
-20
792
-15
988
-10
1208
-5
1458
c
Capacity (ASHRAE)
Comp.\C
SC15CL
-40
175
-35
347
watt
-30
525
-25
714
-23.3
782
-20
920
-15
1149
-10
1407
-5
1699
b
8222
Power consumption
Comp.\C
SC15CL
-40
298
-35
400
watt
-30
485
-25
560
-23.3
584
-20
631
-15
706
-10
790
-5
891
-30
3.28
-25
3.52
-23.3
3.61
-20
3.77
-15
4.04
-10
4.31
-5
4.60
-25
1.10
-23.3
1.15
-20
1.25
-15
1.40
-10
1.53
Current consumption
Comp.\C
SC15CL
-40
2.83
-35
3.05
-40
0.51
-35
0.75
-30
0.93
-40
0.59
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-30
1.08
-25
1.27
-23.3
1.34
EN 12900/CECOMAF
45C
32C
45C
-20
1.46
-15
1.63
-10
1.78
12
-5
1.91
13
14
-5
1.64
W/W
-35
0.87
c
11
10
W/W
COP (ASHRAE)
Comp.\C
SC15CL
a2
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC15CL
Starting relay
a2
117U6019
Cover
103N2009
Starting capacitor 80 F
117U5017
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.C2.02
CK.54.B6.02
August 2002
33
SC15DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.M2.02)
General
SC15DL
Code number
104L2856
104L
SC15DL
Application
R404A
R407C R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
MBP/HBP
Barcode on
white background
-20 to 15
Yellow background
2856
DANFOSS COMPRESSORS
8306-5
Compressor
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
600
1300
cm3
1460
kg
13.5
204
178
170
16
watt
550
21.8
21.8
3.5/12.2
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
219
213
B1
193
B2
110
10.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
August 2002
34
CF.54.M3.02
CK.54.B6.02
107
115
55
63
15.28
8257
September 2002
-20
759
-15
964
-10
1207
watt
-5
1493
0
1825
5
2210
7.2
2397
10
2652
Capacity (ASHRAE)
Comp.\C
SC15DL
-20
881
-15
1121
15
3156
a3
a2
watt
-10
1405
-5
1740
0
2131
5
2585
7.2
2807
10
3109
15
3710
c
8227
Power consumption
Comp.\C
SC15DL
-20
589
-15
659
watt
-10
722
-5
778
0
825
5
865
7.2
879
10
896
15
918
-10
3.79
-5
4.07
0
4.31
5
4.50
7.2
4.57
10
4.64
15
4.75
Current consumption
Comp.\C
SC15DL
-20
3.09
-15
3.46
-20
1.29
-15
1.46
-10
1.67
W/W
-5
1.92
0
2.21
5
2.56
7.2
2.73
10
2.96
COP (ASHRAE)
Comp.\C
SC15DL
-20
1.50
15
3.44
b
e
Start winding
5
a2
Main winding
Winding
protector
1
2
N
L
2
N
L
Bleeder resistance
a3
W/W
-15
1.70
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-10
1.95
-5
2.24
0
2.58
EN 12900/CECOMAF
45C
32C
45C
5
2.99
7.2
3.19
10
3.47
15
4.04
Thermostat
Fan
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC15DL
a3
Starting device
Cover
Starting relay
a2
Starting capacitor
Run capacitor
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
Components
of
starting device
103N1004
118-1917
118-1918
118-1919
CF.54.M3.02
CK.54.B6.02
August 2002
35
SC18CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.D1.02)
General
SC18CL
Code number
104L2123
104L
SC18CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP/MBP
Barcode on
white background
-45 to -5
Yellow background
2123
DANFOSS COMPRESSORS
8296-3
Compressor
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
600
1300
cm3
1460
kg
13.7
204
178
170
16
watt
495
20.0
20.0
3.7/14.1
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
219
213
B1
193
B2
110
10.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
August 2002
36
CF.54.D2.02
CK.54.B6.02
107
115
55
63
17.69
8257
September 2002
-45
167
-40
271
-35
395
watt
-30
542
-25
715
-23.3
781
-20
918
-15
1154
-10
1425
-5
1735
Capacity (ASHRAE)
Comp.\C
SC18CL
-45
193
-40
313
a3
a2
watt
-35
457
-30
628
-25
830
-23.3
907
-20
1067
-15
1342
-10
1659
-5
2022
c
8227
Power consumption
Comp.\C
SC18CL
-45
294
-40
376
watt
-35
455
-30
534
-25
615
-23.3
643
-20
700
-15
792
-10
894
-5
1008
d
Current consumption
Comp.\C
SC18CL
-45
2.61
-40
2.80
A
-35
3.02
-30
3.29
-25
3.60
-23.3
3.72
-20
3.96
-15
4.36
-10
4.80
-5
5.29
b
e
Start winding
5
a2
Main winding
-45
0.57
-40
0.72
-35
0.87
W/W
-30
1.01
-25
1.16
-23.3
1.21
-20
1.31
-15
1.46
-10
1.59
COP (ASHRAE)
Comp.\C
SC18CL
-45
0.66
-5
1.72
Winding
protector
1
2
N
L
2
N
L
W/W
-40
0.83
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-35
1.00
-30
1.18
-25
1.35
EN 12900/CECOMAF
45C
32C
45C
-23.3
1.41
-20
1.52
-15
1.69
-10
1.86
-5
2.01
Bleeder resistance
a3
M
Thermostat
Fan
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC18CL
a3
Starting device
Cover
Starting relay
a2
Starting capacitor 80 F
Run capacitor
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
Components
of
starting device
103N1004
118-1917
118-1918
118-1919
CF.54.D2.02
CK.54.B6.02
August 2002
37
SC21CL
LBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.E1.02)
General
SC21CL
Code number
104L2322
104L
SC21CL
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP
Barcode on
white background
-45 to -10
Yellow background
2322
DANFOSS COMPRESSORS
8296-2
Compressor
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
600
1300
cm3
1460
kg
14.0
204
178
170
16
watt
590
23.4
23.4
3.4/14.4
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
219
213
B1
193
B2
110
10.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
August 2002
38
CF.54.E2.02
CK.54.B6.02
107
115
55
63
20.95
8257
September 2002
-45
226
-40
325
-35
455
watt
-30
617
-25
813
-23.3
887
-20
1042
-15
1306
Capacity (ASHRAE)
Comp.\C
SC21CL
-45
263
-40
378
-10
1606
a3
a2
watt
-35
529
-30
719
-25
947
-23.3
1033
-20
1215
-15
1524
-10
1876
c
8227
Power consumption
Comp.\C
SC21CL
-45
400
-40
462
watt
-35
534
-30
615
-25
702
-23.3
733
-20
795
-15
891
-10
989
-35
2.94
-30
3.31
-25
3.71
-23.3
3.86
-20
4.14
-15
4.58
-10
5.00
Current consumption
Comp.\C
SC21CL
-45
2.40
-40
2.63
-45
0.57
-40
0.70
-35
0.85
W/W
-30
1.00
-25
1.16
-23.3
1.21
-20
1.31
-15
1.47
COP (ASHRAE)
Comp.\C
SC21CL
-45
0.66
-10
1.62
b
e
Start winding
5
a2
Main winding
Winding
protector
1
2
N
L
2
N
L
Bleeder resistance
a3
W/W
-40
0.82
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-35
0.99
-30
1.17
-25
1.35
EN 12900/CECOMAF
45C
32C
45C
-23.3
1.41
-20
1.53
-15
1.71
-10
1.90
Thermostat
Fan
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC21CL
a3
Starting device
Cover
Starting relay
a2
Starting capacitor 80 F
Run capacitor
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
Components
of
starting device
103N1004
118-1917
118-1918
118-1919
CF.54.E2.02
CK.54.B6.02
August 2002
39
SC10/10CL
LBP/MBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.F1.02)
General
SC10/10CL
Code number
104L4087
Application
Application
LBP/MBP
-35 to -5
V/Hz
SC10/10CL
Application
104L
R404A
R507
Lilac stripe
Approvals
4087
Barcode on
white background
8297
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2820
kg
26.3
100
127
2 x 10.29
Motor
Motor size
watt
127
2 x 315
12.6
12.6
6.7/11.8
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
249
244
B1
183
B2
100
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
August 2002
40
CF.54.F2.02
CK.54.B6.02
September 2002
-35
336
-30
517
-25
730
watt
-23.3
810
-20
979
-15
1268
-10
1601
-5
1981
Starting relay
Starting capacitor
Comp.\C
SC10/10CL
-35
390
-30
600
watt
-25
847
-23.3
941
-20
1137
-15
1474
-10
1863
-25
701
-23.3
741
-20
821
-15
942
-10
1060
Power consumption
10 11
12
Main winding
-5
2309
14
1
2
N
L
-35
486
-30
587
1
2
N
L
watt
Current consumption
-35
3.82
-30
4.11
-23.3
4.55
-20
4.79
-15
5.18
-10
5.61
-23.3
1.09
-20
1.19
-15
1.35
-10
1.51
-35
0.69
-30
0.88
-25
1.04
13
14
1
2
N
L
Fan
A
-25
4.43
12
Blue
Black
Brown
-5
1168
Thermostat
Comp.\C
SC10/10CL
Start winding
Winding
protector
1
2
N
L
2 1
Comp.\C
SC10/10CL
10 11
13
1933
Capacity (ASHRAE)
-5
6.08
W/W
-5
1.70
service valve
seal ring
COP (ASHRAE)
Comp.\C
SC10/10CL
-35
0.80
W/W
-30
1.02
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-25
1.21
-23.3
1.27
-20
1.39
EN 12900/CECOMAF
45C
32C
45C
-15
1.57
-10
1.76
-5
1.98
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
pcs.
SC10/10CL
Starting relay
117U6003
Starting capacitor 80 F
117U5017
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
Devices
September 2002
CF.54.F2.02
CK.54.B6.02
August 2002
41
SC10/10DL
MBP/HBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.N2.02)
General
SC10/10DL
Code number
104L4091
Application
Application
MBP/HBP
-20 to 15
V/Hz
SC10/10DL
Application
104L
R404A
R407C R507
Lilac stripe
Approvals
4091
Barcode on
white background
8307
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2820
kg
26.8
100
127
2 x 10.29
Motor
Motor size
watt
127
2 x 385
14.8
14.8
5.0/13.7
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
249
244
B1
183
B2
100
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
August 2002
42
CF.54.N3.02
CK.54.B6.02
September 2002
-20
943
-15
1222
-10
1550
watt
-5
0
1935 2383
5
2900
7.2
3152
10
3494
15
4169
Starting relay
Starting capacitor
10 11
Comp.\C
-20
SC10/10DL 1095
-15
1420
watt
-10
-5
1804 2256
0
2782
5
3392
7.2
3690
10
4095
-10
957
0
1118
5
1180
7.2
1203
10
1228
Power consumption
12
Main winding
15
4901
14
1
2
N
L
-20
747
-15
858
1
2
N
L
watt
-5
1044
Current consumption
-15
5.55
-5
6.30
0
6.60
5
6.85
7.2
6.95
10
7.06
-5
1.85
0
2.13
5
2.46
7.2
2.62
10
2.85
-15
1.42
13
14
1
2
N
L
Fan
A
-10
5.95
12
Blue
Black
Brown
15
1262
Thermostat
Comp.\C
-20
SC10/10DL 5.11
Start winding
Winding
protector
1
2
N
L
2 1
Comp.\C
SC10/10DL
10 11
13
1933
Capacity (ASHRAE)
15
7.21
W/W
-10
1.62
15
3.30
service valve
seal ring
COP (ASHRAE)
Comp.\C
-20
SC10/10DL 1.47
W/W
-15
1.66
-10
1.89
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-5
2.16
0
2.49
5
2.88
EN 12900/CECOMAF
45C
32C
45C
7.2
3.07
10
3.34
15
3.88
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
pcs.
SC10/10DL
Starting relay
117U6005
Starting capacitor 80 F
117U5017
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
Devices
September 2002
CF.54.N3.02
CK.54.B6.02
August 2002
43
SC12/12CL
LBP/MBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.G1.02)
General
SC12/12CL
Code number
104L4088
Application
Application
LBP/MBP
-45 to -5
V/Hz
SC12/12CL
Application
104L
R404A
R507
Lilac stripe
Approvals
4088
Barcode on
white background
8297-4
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2820
kg
27.3
100
127
2 x 12.87
Motor
Motor size
watt
127
2 x 385
14.8
14.8
5.0/13.7
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
249
244
B1
183
B2
100
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
August 2002
44
CF.54.G2.02
CK.54.B6.02
September 2002
-40
279
-35
475
-30
706
watt
-25 -23.3 -20 -15 -10
-5
980 1083 1299 1670 2096 2583
Starting relay
Starting capacitor
Comp.\C
-45
SC12/12CL 134
-40
323
watt
-35
550
-35
633
-30
761
Power consumption
10 11
12
Main winding
14
1
2
N
L
-40
506
Start winding
Winding
protector
1
2
N
L
1
2
N
L
watt
2 1
Comp.\C
-45
SC12/12CL 379
10 11
13
Current consumption
1
2
N
L
Fan
Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC12/12CL 4.30 4.55 4.85 5.22 5.64 5.80 6.13 6.67 7.27 7.94
13
14
Blue
Black
Brown
12
1933
Capacity (ASHRAE)
W/W
Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC12/12CL 0.30 0.55 0.75 0.93 1.10 1.16 1.27 1.44 1.60 1.77
service valve
seal ring
COP (ASHRAE)
W/W
Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC12/12CL 0.35 0.64 0.87 1.08 1.28 1.34 1.47 1.67 1.87 2.06
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC12/12CL
Starting relay
117U6005
Starting capacitor 80 F
117U5017
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CF.54.G2.02
CK.54.B6.02
August 2002
45
SC12/12DL
MBP/HBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.O2.02)
General
SC12/12DL
Code number
104L4092
Application
Application
MBP/HBP
-20 to 15
V/Hz
SC12/12DL
Application
104L
R404A
R407C R507
Lilac stripe
Approvals
4092
Barcode on
white background
8307-3
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2920
kg
27.8
100
127
2 x 12.87
Motor
Motor size
watt
127
2 x 495
18.6
18.6
3.7/14.1
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
249
244
B1
183
B2
100
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
August 2002
46
CF.54.O3.02
CK.54.B6.02
September 2002
-15
-10
1612 2055
watt
-5
2559
0
3130
5
3780
7.2
4092
10
4516
15
5348
Starting relay
Starting capacitor
10 11
Comp.\C
-20
SC12/12DL 1414
watt
-15
-10
1874 2393
-5
2982
0
3654
5
4421
7.2
10
4791 5294
-5
1349
0
1433
5
1500
7.2
1526
Power consumption
12
Main winding
15
6287
14
1
2
N
L
-20
978
-15
1125
1
2
N
L
watt
-10
1248
10
1555
Current consumption
-15
7.29
-5
8.21
0
8.58
5
8.88
7.2
9.00
10
9.13
-5
1.90
0
2.18
5
2.52
7.2
2.68
10
2.90
-15
1.43
-10
1.65
13
14
1
2
N
L
Fan
A
-10
7.78
12
Blue
Black
Brown
15
1600
Thermostat
Comp.\C
-20
SC12/12DL 6.74
Start winding
Winding
protector
1
2
N
L
2 1
Comp.\C
SC12/12DL
10 11
13
1933
Capacity (ASHRAE)
15
9.31
W/W
15
3.34
service valve
seal ring
COP (ASHRAE)
Comp.\C
-20
SC12/12DL 1.45
W/W
-15
1.67
-10
1.92
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-5
2.21
0
2.55
5
2.95
EN 12900/CECOMAF
45C
32C
45C
7.2
3.14
10
3.40
15
3.93
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
pcs.
SC12/12DL
Starting relay
117U6019
Starting capacitor 80 F
117U5017
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
Devices
September 2002
CF.54.O3.02
CK.54.B6.02
August 2002
47
SC15/15CL
LBP/MBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.H1.02)
General
SC15/15CL
Code number
104L4089
Application
Application
LBP/MBP
-40 to -5
V/Hz
SC15/15CL
Application
104L
R404A
R507
Lilac stripe
Approvals
4089
Barcode on
white background
8297-5
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2920
kg
29.1
100
127
2 x 15.28
Motor
Motor size
watt
127
2 x 495
18.6
18.6
3.7/14.1
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
259
254
B1
193
B2
110
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
August 2002
48
CF.54.H2.02
CK.54.B6.02
September 2002
-40
302
-35
599
-30
905
watt
-25 -23.3
1230 1347
-20
1584
-15
-10
1976 2417
-5
2916
Starting relay
Starting capacitor
Comp.\C
SC15/15CL
-40
350
-35
694
watt
-30
1050
-25 -23.3
1428 1563
-20
-15
1840 2298
-30
970
-25 -23.3
1120 1169
-20
1262
-10
2813
Power consumption
10 11
12
Main winding
-5
3398
14
1
2
N
L
-40
597
-35
801
1
2
N
L
watt
-15
-10
1411 1580
Current consumption
-35
6.10
-25
7.04
-23.3
7.21
-20
7.55
-15
8.08
-10
8.62
-25
1.10
-23.3
1.15
-20
1.25
-15
1.40
-10
1.53
-35
0.75
-30
0.93
13
14
1
2
N
L
Fan
A
-30
6.56
12
Blue
Black
Brown
-5
1782
Thermostat
Comp.\C
-40
SC15/15CL 5.66
Start winding
Winding
protector
1
2
N
L
2 1
Comp.\C
SC15/15CL
10 11
13
1933
Capacity (ASHRAE)
-5
9.19
W/W
-5
1.64
service valve
seal ring
COP (ASHRAE)
Comp.\C
-40
SC15/15CL 0.59
W/W
-35
0.87
-30
1.08
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-25
1.27
-23.3
1.34
-20
1.46
EN 12900/CECOMAF
45C
32C
45C
-15
1.63
-10
1.78
-5
1.91
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC15/15CL
117U6019
Starting capacitor 80 F
117U5017
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
Starting relay
September 2002
CF.54.H2.02
CK.54.B6.02
August 2002
49
SC15/15DL
MBP/HBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.P2.02)
General
SC15/15DL
Code number
104L4093
Application
Application
MBP/HBP
-20 to 15
V/Hz
SC15/15DL
Application
104L
R404A
R407C R507
Lilac stripe
Approvals
4093
Barcode on
white background
8307-2
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2920
kg
28.0
100
127
2 x 15.28
Motor
Motor size
watt
127
2 x 550
21.8
21.8
3.5/12.1
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
259
254
B1
193
B2
110
B1
B2
1"-14 UNF
location/I.D. mm
16
Solder connector
location/I.D. mm
16
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8265
18
326
August 2002
50
CF.54.P3.02
CK.54.B6.02
September 2002
watt
-5
2985
0
5
3651 4420
7.2
4795
10
5304
-5
3479
0
4262
7.2
5613
10
6218
Capacity (ASHRAE)
Comp.\C
-20
-15
SC15/15DL 1763 2242
-15
1319
5
5170
15
7419
-15
6.93
-10
1445
-5
1556
0
5
1651 1730
7.2
1760
10
1793
-10
7.58
-5
8.14
0
8.61
5
9.00
7.2
9.14
10
9.29
-15
1.46
-5
1.92
0
2.21
5
2.55
7.2
2.72
10
2.96
15
9.50
1
2
N
L
15
1837
1
2
N
L
watt
Current consumption
Comp.\C
-20
SC15/15DL 6.19
Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance
watt
-10
2810
Power consumption
Comp.\C
-20
SC15/15DL 1178
15
6311
1
2
N
L
2 1
Thermostat
1932
Comp.\C
-20
SC15/15DL 1518
1
2
N
L
Blue
Black
Brown
Time delay
relay
Safety pressure control
Fan
Thermostat 2
W/W
-10
1.67
15
3.43
service valve
seal ring
COP (ASHRAE)
Comp.\C
-20
SC15/15DL 1.50
W/W
-15
1.70
-10
1.94
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-5
2.24
0
2.58
5
2.99
EN 12900/CECOMAF
45C
32C
45C
7.2
3.19
10
3.47
15
4.04
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC15/15DL
Starting device
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7351
(16 mm)
118-7405
(16 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CF.54.P3.02
CK.54.B6.02
August 2002
51
SC18/18CL
LBP/MBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.I1.02)
General
SC18/18CL
Code number
104L4090
Application
Application
LBP/MBP
-45 to -5
V/Hz
SC18/18CL
Application
104L
R404A
R507
Lilac stripe
Approvals
4090
Barcode on
white background
8297-2
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2920
kg
29.1
100
127
2 x 17.69
Motor
Motor size
watt
127
2 x 495
20.0
20.0
3.7/14.1
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
259
254
B1
193
B2
110
B1
B2
1"-14 UNF
location/I.D. mm
16
Solder connector
location/I.D. mm
16
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8265
18
326
August 2002
52
CF.54.I2.02
CK.54.B6.02
September 2002
watt
Capacity (ASHRAE)
Comp.\C
-45
SC18/18CL 386
watt
-40
627
Power consumption
watt
Comp.\C
-45
SC18/18CL 587
-40
752
Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance
1
2
N
L
Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC18/18CL 5.22 5.59 6.04 6.58 7.21 7.44 7.92 8.72 9.61 10.58
1
2
N
L
Current consumption
1
2
N
L
2 1
Thermostat
1932
Comp.\C
-45
SC18/18CL 333
1
2
N
L
Blue
Black
Brown
Time delay
relay
Safety pressure control
Fan
Thermostat 2
W/W
-30 -25 -23.3 -20 -15 -10
-5
1.01 1.16 1.21 1.31 1.46 1.59 1.72
service valve
seal ring
COP (ASHRAE)
W/W
Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC18/18CL 0.66 0.83 1.00 1.18 1.35 1.41 1.52 1.69 1.85 2.01
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
45C
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
Starting device
pcs.
SC18/18CL
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7351
(16 mm)
118-7405
(16 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CF.54.I2.02
CK.54.B6.02
August 2002
53
SC21/21CL
LBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.J1.02)
General
SC21/21CL
Code number
104L4094
Application
Application
LBP
-45 to -10
V/Hz
SC21/21CL
Application
104L
R404A
R507
Lilac stripe
Approvals
4094
Barcode on
white background
8297-3
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2920
kg
29.1
100
127
2 x 20.95
Motor
Motor size
watt
127
2 x 590
23.4
23.4
3.4/14.4
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
259
254
B1
193
B2
110
B1
B2
1"-14 UNF
location/I.D. mm
16
Solder connector
location/I.D. mm
16
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8265
18
326
August 2002
54
CF.54.J2.02
CK.54.B6.02
September 2002
-40
650
watt
-35
910
-30
1235
-15
2613
-35
1059
-30
1437
-15
3049
Capacity (ASHRAE)
Comp.\C
SC21/21CL
-45
525
-40
755
-45
799
-40
924
-10
3753
-40
5.27
-35
1068
-30
1230
-25 -23.3
1404 1466
-20
1589
-15
1782
-35
5.88
-30
6.61
-25
7.42
-23.3
7.71
-20
8.28
-15
9.15
-40
0.70
-35
0.85
-30
1.00
-25
1.16
-23.3
1.21
-20
1.31
-15
1.47
-10
9.99
1
2
N
L
-10
1978
1
2
N
L
watt
Current consumption
Comp.\C
-45
SC21/21CL 4.80
Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance
watt
Power consumption
Comp.\C
SC21/21CL
-10
3213
1
2
N
L
2 1
Thermostat
1932
Comp.\C
SC21/21CL
1
2
N
L
Blue
Black
Brown
Time delay
relay
Safety pressure control
Fan
Thermostat 2
W/W
-10
1.62
service valve
seal ring
COP (ASHRAE)
Comp.\C
-45
SC21/21CL 0.66
W/W
-40
0.82
-35
0.99
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-30
1.17
-25
1.35
-23.3
1.41
EN 12900/CECOMAF
45C
32C
45C
-20
1.53
-15
1.71
-10
1.90
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
Starting device
pcs.
SC21/21CL
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7351
(16 mm)
118-7405
(16 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CF.54.J2.02
CK.54.B6.02
August 2002
55
SC12CLX
LBP Compressor
R404A/R507
220-240V 60Hz
Data Sheet (Replaces CF.54.T2.02)
General
SC12CLX
Code number
104L2695
104L
SC12CLX
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP
Barcode on
white background
-40 to -10
Yellow background
2695
DANFOSS COMPRESSORS
38
32C
F2
38C
F2
SC12CLX
230V-60Hz
1PH
THERMALLY
PROTECTED
Approval mark
Design
Displacement
cm3
Oil quantity
cm3
550
1300
cm3
1510
kg
13.7
S
O
F1
12.87
F2
204
178
170
16
watt
495
18.6
18.6
3.7/14.1
Approvals
70
150
Motor size
UL984/CSA-C22.2
127
165
186
218
D
Dimensions
location/I.D. mm
219
213
B1
193
B2
110
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Suction connector
mm
19
9.7
127
101.6
35
Motor
37
37
107
September 2002
56
CF.54.T3.02
CK.54.B6.02
107
115
55
63
Height
8349-5
Motor type
8349-2
Compressor
8258
September 2002
-40
146
-35
282
-30
429
watt
-25
590
-23.3
649
-20
770
-15
972
-10
1200
c
Capacity (ASHRAE)
Comp.\C
SC12CLX
-40
169
-35
327
watt
-30
497
-25
685
-23.3
753
-20
894
-15
1130
-10
1397
b
8222
Power consumption
Comp.\C
SC12CLX
-40
277
-35
376
watt
-30
462
-25
540
-23.3
566
-20
616
-15
696
-10
784
a2
d
Current consumption
Comp.\C
SC12CLX
-40
2.58
-35
2.75
A
-30
2.96
-25
3.23
-23.3
3.33
-20
3.54
-15
3.91
-10
4.32
c
11
10
-40
0.53
W/W
-35
0.75
-30
0.93
-25
1.09
-23.3
1.15
-20
1.25
-15
1.40
-35
0.87
-30
1.08
-25
1.27
-23.3
1.33
-20
1.45
-15
1.62
COP (ASHRAE)
Comp.\C
SC12CLX
-40
0.61
-10
1.53
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz
EN 12900/CECOMAF
45C
32C
45C
-10
1.78
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC12CLX
Starting relay
a2
117U6019
103N2008
Cover
Starting capacitor 80 F
117U5019
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.T3.02
CK.54.B6.02
September 2002
57
SC15CLX
LBP Compressor
R404A/R507
220-240V 60Hz
Data Sheet (Replaces CF.54.R2.02)
General
SC15CLX
Code number
104L2854
104L
SC15CLX
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP
Barcode on
white background
-40 to -10
Yellow background
2854
DANFOSS COMPRESSORS
CSR
38
32C
F2
38C
F2
SC15CLX
230V-60Hz
1PH
8349-6
Motor type
THERMALLY
PROTECTED
Approval mark
Design
Displacement
cm3
Oil quantity
cm3
550
1300
cm3
1510
kg
13.7
S
O
F1
15.28
F2
204
178
170
16
watt
550
21.8
21.8
3.5/12.1
Approvals
70
150
Motor size
UL984/CSA-C22.2
127
165
186
218
D
Dimensions
location/I.D. mm
219
213
B1
193
B2
110
10.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Suction connector
mm
19
9.7
127
101.6
35
Motor
37
37
107
September 2002
58
CF.54.R3.02
CK.54.B6.02
107
115
55
63
Height
8349
Compressor
8257
September 2002
-40
179
-35
351
-30
530
watt
-25
720
-23.3
788
-20
928
-15
1158
Capacity (ASHRAE)
Comp.\C
SC15CLX
-40
208
-35
407
-10
1417
a3
a2
watt
-30
614
-25
836
-23.3
915
-20
1078
-15
1347
-10
1649
c
8227
Power consumption
Comp.\C
SC15CLX
-40
303
-35
414
watt
-30
515
-25
610
-23.3
641
-20
699
-15
783
-10
864
-30
2.46
-25
2.90
-23.3
3.05
-20
3.33
-15
3.73
-10
4.11
Current consumption
Comp.\C
SC15CLX
-40
1.51
-35
1.99
-40
0.59
-35
0.85
-30
1.03
W/W
-25
1.18
-23.3
1.23
-20
1.33
-15
1.48
COP (ASHRAE)
Comp.\C
SC15CLX
-40
0.68
-10
1.64
b
e
Start winding
5
a2
Main winding
Winding
protector
1
2
N
L
2
N
L
Bleeder resistance
a3
W/W
-35
0.98
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz
-30
1.19
-25
1.37
-23.3
1.43
EN 12900/CECOMAF
45C
32C
45C
-20
1.54
-15
1.72
-10
1.91
Thermostat
Fan
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC15CLX
a3
Starting device
Cover
Starting relay
a2
Starting capacitor
Run capacitor
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
Components of
starting device
103N1004
118-1917
118-1918
118-1919
CF.54.R3.02
CK.54.B6.02
September 2002
59
SC10/10CLX
LBP/MBP Twin Compressor
R404A/R507
220-240V 60Hz
Data Sheet
General
SC10/10CLX
Code number
104L4033
Application
Application
LBP/MBP
-35 to -5
V/Hz
SC10/10CLX
Application
104L
R404A
R507
Lilac stripe
Approvals
4033
Barcode on
white background
8461
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2820
kg
26.8
100
127
2 x 10.29
Motor
Motor size
watt
127
2 x 385
14.8
14.8
16
175
302
5.0/13.7
Approvals
Dimensions
Height
mm
249
244
B1
183
B2
100
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
January 2002
60
CJ.54.F1.02
CK.54.B6.02
September 2002
-35
448
-30
670
-25
910
watt
-23.3
998
-20
1176
-15
1476
-10
1812
-5
2192
Starting relay
Starting capacitor
10 11
Comp.\C
SC10/10CLX
-35
520
watt
-30
776
-25
1056
-23.3
1158
-20
1366
-15
1714
-10
2108
-25
860
-23.3
900
-20
978
-15
1104
-10
1246
Power consumption
Comp.\C
SC10/10CLX
-35
608
-30
740
-35
4.38
-30
4.72
-35
0.74
-30
0.90
1
2
N
L
-20
9.78
-15
6.04
-10
6.60
-25
1.06
-23.3
1.11
-20
1.20
-15
1.34
-10
1.45
1
2
N
L
2 1
-5
1414
Start winding
Winding
protector
1
2
N
L
Thermostat
12
13
14
1
2
N
L
Blue
Black
Brown
Fan
A
-23.3
5.24
14
watt
-25
5.10
10 11
13
Main winding
-5
2554
Current consumption
Comp.\C
SC10/10CLX
12
1933
Capacity (ASHRAE)
-5
7.22
W/W
-5
1.55
service valve
seal ring
COP (ASHRAE)
Comp.\C
SC10/10CLX
-35
0.85
W/W
-30
1.05
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz
-25
1.23
-23.3
1.29
-20
1.40
EN 12900/CECOMAF
45C
32C
45C
-15
1.55
-10
1.69
-5
1.81
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC10/10CLX
Starting relay
117U6005
Starting capacitor 80 F
117U5019
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CJ.54.F1.02
CK.54.B6.02
January 2002
61
SC12/12CLX
LBP Twin Compressor
R404A/R507
220-240V 60Hz
Data Sheet
General
SC12/12CLX
Code number
104L4034
Application
Application
LBP
-40 to -10
V/Hz
SC12/12CLX
Application
104L
R404A
R507
Lilac stripe
Approvals
4034
Barcode on
white background
8461-2
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2820
kg
28.0
100
127
2 x 12.87
Motor
Motor size
watt
127
2 x 495
18.6
18.6
16
175
302
3.7/14.1
Approvals
Dimensions
Height
mm
259
254
B1
193
B2
100
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
January 2002
62
CJ.54.G1.02
CK.54.B6.02
September 2002
-40
292
-35
564
-30
858
watt
-25
1180
-23.3
1298
-20
1540
-15
1944
-10
2400
Starting relay
Starting capacitor
10 11
Comp.\C
SC12/12CLX
-40
338
watt
-35
654
-30
994
-25
1370
-23.3
1506
-20
1788
-15
2260
-30
924
-25
1080
-23.3
1132
-20
1232
-15
1392
Power consumption
Comp.\C
SC12/12CLX
-40
554
-35
752
-40
5.16
-35
5.50
-40
0.53
-35
0.75
1
2
N
L
-23.3
6.66
-20
7.08
-15
7.82
-30
0.93
-25
1.09
-23.3
1.15
-20
1.25
-15
1.40
1
2
N
L
2 1
-10
1568
Start winding
Winding
protector
1
2
N
L
Thermostat
12
13
14
1
2
N
L
Blue
Black
Brown
Fan
A
-25
6.46
14
watt
-30
5.92
10 11
13
Main winding
-10
2794
Current consumption
Comp.\C
SC12/12CLX
12
1933
Capacity (ASHRAE)
-10
8.64
W/W
-10
1.53
service valve
seal ring
COP (ASHRAE)
Comp.\C
SC12/12CLX
-40
0.61
W/W
-35
0.87
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz
-30
1.08
-25
1.27
-23.3
1.33
EN 12900/CECOMAF
45C
32C
45C
-20
1.45
-15
1.62
-10
1.78
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC12/12CLX
Starting relay
117U6019
Starting capacitor 80 F
117U5019
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CJ.54.G1.02
CK.54.B6.02
January 2002
63
SC15/15CLX
LBP Twin Compressor
R404A/R507
220-240V 60Hz
Data Sheet
General
SC15/15CLX
Code number
104L4097
Application
Application
LBP
-40 to -10
V/Hz
SC15/15CLX
Application
104L
R404A
R507
Lilac stripe
Approvals
4097
Barcode on
white background
8461-3
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2920
kg
28.0
100
127
2 x 15.28
Motor
Motor size
watt
127
2 x 550
21.8
21.8
16
175
302
3.5/12.1
Approvals
Dimensions
Height
mm
259
254
B1
193
B2
110
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8265
18
326
January 2002
64
CJ.54.H1.02
CK.54.B6.02
September 2002
watt
-35
702
-30
1060
-25
1440
-23.3
1576
-20
1856
-15
2316
-10
2834
-35
814
-30
1228
-25
1672
-23.3
1830
-20
2156
-15
2694
-10
3298
Capacity (ASHRAE)
Comp.\C
SC15/15CLX
-40
416
watt
Power consumption
Comp.\C
SC15/15CLX
-40
606
Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance
-35
828
1
2
N
L
watt
-30
1030
-25
1220
-23.3
1282
-20
1398
-15
1566
-40
3.02
-35
3.98
A
-30
4.92
-25
5.80
-23.3
6.10
-20
6.66
-15
7.46
-25
1.18
-23.3
1.23
-20
1.33
-15
1.48
-40
0.59
-35
0.85
-30
1.03
1
2
N
L
2 1
Thermostat
Comp.\C
SC15/15CLX
1
2
N
L
-10
1728
Current consumption
-10
8.22
1932
Comp.\C
SC15/15CLX
1
2
N
L
Blue
Black
Brown
Time delay
relay
Safety pressure control
Fan
Thermostat 2
W/W
-10
1.64
service valve
seal ring
COP (ASHRAE)
Comp.\C
SC15/15CLX
-40
0.68
W/W
-35
0.98
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz
-30
1.19
-25
1.37
-23.3
1.43
EN 12900/CECOMAF
45C
32C
45C
-20
1.54
-15
1.72
-10
1.91
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC15/15CLX
Starting device
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CJ.54.H1.02
CK.54.B6.02
January 2002
65
SC10CLX
LBP/MBP Compressor
R404A/R507
220-240V 50/60Hz
Data Sheet (Replaces CF.54.S2.02)
General
SC10CLX
Code number
104L2533
Code number
104L2536
104L
SC10CLX
Application
R404A
R507
Lilac stripe
Approvals
2533
Barcode on
white background
Application
Application
LBP/MBP
DANFOSS COMPRESSORS
Yellow background
8349
Compressor
50Hz: -35 to 5
60Hz: -35 to -5
SC10CLX
208-230V-60Hz
1PH
CSIR
38
32C
F2
THERMALLY
PROTECTED
Approval mark
38C
F2
S
O
F1
cm3
10.29
F2
Design
Displacement
Oil quantity
550
1300
cm3
1460
kg
13.1
cm
Motor size
watt
385
14.8
14.8
70
150
104L2536
209
203
B1
183
B A
B1
B2
100
8.2 0.09
location/I.D. mm
6.2 0.09
6.5 0.09
Discharge connector
location/I.D. mm
6.2 0.09
6.5 0.09
80
63
Process connector
55
151
8.2 0.09
255
location/I.D. mm
pcs.
104L2533
mm
B2
37
37
107
September 2002
66
UL984/CSA-C22.2
Dimensions
Compressors on a pallet
19
9.7
127
165
186
218
5.0/13.7
Approvals
Suction connector
204
178
170
16
Motor
Height
127
101.6
35
8349-8
V/Hz
CF.54.S3.02
CK.54.B6.02
107
115
55
63
Voltage range
8258
September 2002
-35
166
224
-30
255
335
-25
360
455
watt
-23.3
400
499
-20
483
588
-15
625
738
-10
789
906
-5
977
1096
0
1190
Capacity (ASHRAE)
Evap. temp in C
SC10CLX, 50Hz
SC10CLX, 60Hz
-35
192
260
5
1430
watt
-30
296
388
-25
418
528
-23.3
464
579
-20
561
683
-15
727
857
-10
919
1054
-5
1139
1277
0
1389
5
1673
b
8222
Power consumption
Evap. temp in C
SC10CLX, 50Hz
SC10CLX, 60Hz
-35
258
304
watt
-30
302
370
-25
352
430
-23.3
369
450
-20
404
489
-15
457
552
-10
508
623
-5
556
707
0
597
5
631
d
Current consumption
Evap. temp in C -35
SC10CLX, 50Hz 2.00
SC10CLX, 60Hz 2.19
a2
A
-30
2.15
2.36
-25
2.32
2.55
-23.3
2.38
2.62
-20
2.51
2.77
-15
2.72
3.02
-10
2.94
3.30
-5
3.19
3.61
0
3.45
5
3.73
c
11
10
W/W
-30
0.84
0.90
-25
1.02
1.06
-23.3
1.08
1.11
-20
1.20
1.20
-15
1.37
1.34
-10
1.55
1.45
-5
1.76
1.55
0
1.99
-30
0.98
1.05
-25
1.19
1.23
-23.3
1.26
1.29
-20
1.39
1.40
-15
1.59
1.55
-10
1.81
1.69
-5
2.05
1.81
0
2.33
COP (ASHRAE)
Evap. temp in C -35
SC10CLX, 50Hz 0.75
SC10CLX, 60Hz 0.85
5
2.27
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V
EN 12900/CECOMAF
45C
32C
45C
5
2.65
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC10CLX
Starting Relay
a2
117U6005
103N2008
Cover
Starting capacitor 80 F
117U5019
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.S3.02
CK.54.B6.02
September 2002
67
SC10MLX
MBP Compressor
R404A/R507
220-240V 50Hz & 208-230V 60Hz
Data Sheet
General
SC10MLX
Code number
104L2506
104L
SC10MLX
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
C (F)
Voltage range
V/Hz
MBP
Barcode on
white background
Yellow background
2506
DANFOSS COMPRESSORS
8365
Compressor
SC10MLX
CSIR
C (F)
208-230V-60Hz
43 (110)
F2
38C (100F)
F2
43C (110F)
F2
1PH
THERMALLY
PROTECTED
Approval mark
S
O
F1
Design
cm3
10.29
Oil quantity
cm3
600
1300
cm3
1410
kg
13.1
Motor
Motor size
watt
470
18.4
18.4
4.3/15.3
F2
204
178
170
16
19
9.7
127
101.6
35
Displacement
70
150
8465-2
Motor type
127
165
186
218
EN 60335-2-34, UL984/CSA-C22.2
C
E
Dimensions
B1
183
B2
100
Suction connector
location/I.D. mm
8.2 0.09
Process connector
location/I.D. mm
6.5 0.09
Discharge connector
location/I.D. mm
6.5 0.09
pcs.
80
B2
255
55
Compressors on a pallet
B A
B1
63
209
203
37
37
107
August 2002
68
CJ.54.L1.02
CK.54.B6.02
107
115
55
63
A
B
mm
151
Height
8258
September 2002
-10
-23.3
1538
462
2.88
3.33
0
-17.8
2118
542
3.15
3.91
10
-12.2
2796
619
3.45
4.52
14
-10.0
3099
650
3.58
4.77
20
-6.7
3590
697
3.79
5.15
30
-1.1
4517
778
4.18
5.80
40
4.4
5597
867
4.60
6.45
45
7.2
6200
916
4.83
6.77
10
-12.2
2386
536
3.70
4.45
14
-10.0
2636
557
3.78
4.73
20
-6.7
3043
587
3.90
5.18
30
-1.1
3817
638
4.12
5.99
40
4.4
4721
687
4.36
6.87
45
7.2
5227
712
4.49
7.34
0
32
1510
740
4.02
2.04
5
41
1812
817
4.36
2.22
0
32
1278
594
3.96
2.15
5
41
1537
633
4.14
2.43
-10
-23.3
1362
428
3.35
3.18
0
-17.8
1830
483
3.52
3.79
b
8222
a2
d
-23.3
-10
547
470
2.87
1.16
-20
-4
646
504
2.99
1.28
-15
5
816
557
3.20
1.47
-10
14
1015
612
3.44
1.66
-6.7
20
1164
651
3.62
1.79
-5
23
1246
672
3.72
1.85
c
11
10
12
13
14
-23.3
-10
465
416
3.31
1.12
-20
-4
546
442
3.39
1.23
-15
5
687
481
3.51
1.43
Test conditions
EN 12900/CECOMAF
Condensing temperature 45C
Return gas temperature
32C
Liquid temperature
45C
50Hz: Fan cooling F2 , 220V
60Hz: Fan cooling F2 , 230V
-10
14
855
518
3.65
1.65
-6.7
20
981
543
3.75
1.81
-5
23
1051
556
3.80
1.89
Start winding
Main winding
Winding protector
ASHRAE
54.4C
35.0C
46.1C
Accessories
Devices
Fig.
Starting Relay
a2
SC10MLX
117U6011
Cover
103N2008
Starting capacitor 80 F
117U5019
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CJ.54.L1.02
CK.54.B6.02
August 2002
69
SC12CLX.2
LBP Compressor
R404A/R507
220-240V 50/60Hz
Data Sheet
General
SC12CLX.2
Code number
104L2697
104L
SC12CLX.2
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
LBP
Barcode on
white background
-40 to -10
Yellow background
2697
DANFOSS COMPRESSORS
8469
Compressor
SC12CLX.2
230V-60Hz
1PH
CSIR
38
32C
F2
38C
F2
8469-2
Motor type
THERMALLY
PROTECTED
Approval mark
S
O
F1
Design
Displacement
cm3
Oil quantity
cm3
550
1300
1510
kg
13.7
12.87
cm
F2
204
178
170
16
19
9.7
watt
495
18.6
18.6
3.7/14.1
Approvals
UL984/CSA-C22.2
70
150
Motor size
127
101.6
35
Motor
127
165
186
218
Dimensions
E
A
219
213
B1
193
B2
110
Suction connector
location/I.D. mm
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
B2
255
80
55
63
151
Compressors on a pallet
B A
B1
37
37
107
September 2002
70
CJ.54.C1.02
CK.54.B6.02
107
115
55
63
mm
Height
8258
September 2002
-40
-35
240
380
watt
-30
-25
540
645
-23.3
-20
-15
1146
Capacity (ASHRAE)
Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz
-10
c
watt
-40
-35
169
327
-30
-25
626
748
-23.3
-20
-15
-10
1397
b
8222
Power consumption
Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz
watt
-40
-35
344
425
-30
-25
487
570
-23.3
-20
-15
-10
Current consumption
Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz
a2
772
-40
-35
2.40
2.70
-30
-25
3.32
3.27
-23.3
-20
-15
-10
c
4.16
11
10
-40
-35
0.70
0.89
-40
-35
0.80
1.03
W/W
-30
-25
1.11
1.13
-23.3
-25
1.28
1.31
-23.3
-20
-15
12
13
14
1.48
COP (ASHRAE)
Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz
-10
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V
preliminary data
-30
EN 12900/CECOMAF
45C
32C
45C
-20
-15
-10
1.73
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
Starting Relay
a2
SC12CLX.2
117U6019
Cover
103N2008
Starting capacitor 80 F
117U5019
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
118-1917
118-1918
118-1919
CJ.54.C1.02
September 2002
CK.54.B6.02
September 2002
71
SC12MLX
MBP Compressor
R404A/R507
220-240V 50Hz & 208-230V 60Hz
Data Sheet
General
SC12MLX
Code number
104L2606
104L
SC12MLX
Application
R404A
R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
C (F)
Voltage range
V/Hz
MBP
Barcode on
white background
Yellow background
2606
8365-3
Compressor
DANFOSS COMPRESSORS
SC12MLX
CSIR
C (F)
208-230V-60Hz
43 (110)
F2
38C (100F)
F2
43C (110F)
F2
1PH
THERMALLY
PROTECTED
Approval mark
S
O
F1
Design
cm3
Oil quantity
cm
12.87
1300
cm3
1410
kg
13.9
Motor
Motor size
watt
590
23.4
23.4
F2
600
3.4/14.4
204
178
170
16
19
9.7
127
101.6
35
Displacement
70
150
8465-4
Motor type
127
165
186
218
EN 60335-2-34, UL984/CSA-C22.2
E
Dimensions
B1
193
B2
110
Suction connector
location/I.D. mm
8.2 0.09
Process connector
location/I.D. mm
6.5 0.09
Discharge connector
location/I.D. mm
6.5 0.09
pcs.
80
B2
265
55
Compressors on a pallet
B A
B1
37
37
107
August 2002
72
CJ.54.M1.02
CK.54.B6.02
107
115
63
219
213
59.5
55
A
B
mm
151
Height
8432-2
September 2002
-10
-23.3
1885
551
3.39
3.42
0
-17.8
2554
646
3.70
3.95
10
-12.2
3335
738
4.06
4.52
14
-10.0
3684
775
4.21
4.75
20
-6.7
4250
831
4.46
5.12
30
-1.1
5320
928
4.92
5.73
40
4.4
6564
1035
5.42
6.34
45
7.2
7259
1092
5.69
6.64
10
-12.2
2915
641
4.15
4.55
14
-10.0
3213
667
4.25
4.82
20
-6.7
3700
705
4.40
5.25
30
-1.1
4622
768
4.67
6.02
40
4.4
5701
829
4.96
6.87
45
7.2
6304
860
5.11
7.33
-5
23
1465
801
4.37
1.83
0
32
1770
882
4.73
2.01
5
41
2118
975
5.14
2.17
-5
23
1272
667
4.27
1.91
0
32
1542
714
4.47
2.16
5
41
1852
762
4.69
2.43
-10
-23.3
1694
507
3.72
3.34
0
-17.8
2252
575
3.92
3.91
-23.3
-10
659
561
3.38
1.18
-20
-4
773
601
3.52
1.29
-15
5
970
664
3.76
1.46
-10
14
1199
729
4.05
1.64
-6.7
20
1370
776
4.26
1.77
8468
a2
b
a2
Start winding
c
Main winding
Thermostat
Winding protector
-23.3
-10
572
493
3.67
1.16
-20
-4
669
525
3.76
1.27
-15
5
838
572
3.91
1.46
Test conditions
EN 12900/CECOMAF
Condensing temperature 45C
Return gas temperature
32C
Liquid temperature
45C
50Hz: Fan cooling F2 , 220V
60Hz: Fan cooling F2 , 230V
-10
14
1038
620
4.08
1.68
-6.7
20
1188
651
4.20
1.83
ASHRAE
54.4C
35.0C
46.1C
Accessories
Devices
Fig.
SC12MLX
Starting Relay
a2
117-7426
a2
117-7422
Cover
1117U1021
Starting capacitor 80 F
117U5019
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CJ.54.M1.02
CK.54.B6.02
August 2002
73
TF4CLX
LBP/MBP Compressor
R404A/R507
115-127V 60Hz
Data Sheet (Replaces CF.52.E1.22)
General
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
102U
TF4CLX
TF4CLX
Connector-material
Application
Code number
R404A
R507
Lilac stripe
102U2102
2102
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
LBP/MBP
F (C)
V/Hz
TF4CLX
115V-60Hz
1PH
95 - 135 /60
Motor type
CSIR
F (C)
THERMALLY
PROTECTED
110 (43)
Comp. cooling at
110F (43C)
F1
S
O
F1
F2
Design
3
17.5 (500)
fl.oz. (cm3)
57.3 (1690)
lbs. (kg)
17.9 (8.1)
Motor
4.02"(102)
watt
225
20.0
20.0
C or
D
8370
or
8.90"(226)
6.93"(176)
6.65 (169)
Suction connector
Process connector
Discharge connector
4.13"(105)
4.21"(107)
0.75"(19)
6.50"(165)
0.63"(16)
0.14"(3.6)
2.76"(70)
6.81 (173)
4.13"(105)
A B
in. (mm) A
31.5
28
UL984/CSA-C22.2
Dimensions
D
C
E
2.6/3.8
Approvals
pcs.
3.78"(96)
4.61"(117)
30
Motor size
Compressors on a pallet
45
(29)
9.5 (280)
oz. (g)
0.23 (3.86)
125
5.35"(136)
fl.oz. (cm3)
51 20
cu.in. (cm )
Oil quantity
6.18"(157)
Displacement
Approval mark
2.34"(59.5)
2.60" (66)
1.14"
2.80"(71)
Voltage range
4.00"(101.6)
8404-2
Application
Height
8404
Compressor
6.70"(170)
7.01"(178)
8.03"(204)
September 2002
74
CF.52.E2.22
CK.54.B6.02
September 2002
Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
CECOMAF
-40
-40
223
290
190
71
-30
-20
-34.4 -28.9
354
512
421 582
302
437
104
145
-13
-25
641
714
547
178
-10
0
10
-23.3 -17.8 -12.2
702
928 1197
776 1008 1282
599
791 1018
194
252
321
20
-6.7
1512
1603
1285
401
30
40
45
-1.1
4.4
7.2
1880 2306 2544
1973 2398 2632
1595 1953 2151
493
599
657
-49
-45
97
106
97
103
-40
-40
117
121
117
120
-30
-20
-34.4 -28.9
139
160
138
155
139
160
138
156
-13
-25
176
169
176
169
-49
-45
2.01
2.05
2.01
2.03
-40
-40
2.07
2.08
2.07
2.08
-30
-20
-34.4 -28.9
2.16 2.29
2.16 2.27
2.16 2.29
2.15 2.27
-49
-45
1.27
1.83
1.09
0.43
-40
-40
1.90
2.39
1.62
0.59
-30
-20
-34.4 -28.9
2.55 3.19
3.06 3.75
2.18 2.72
0.76 0.93
EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
CECOMAF
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz
-13
-25
2.41
2.36
2.41
2.36
a2
watt
-10
0
10
-23.3 -17.8 -12.2
184
209
239
175
198
226
184
209
239
176
199
227
20
-6.7
273
259
273
260
30
-1.1
313
299
313
300
40
4.4
360
347
360
348
45
7.2
387
374
387
375
8226
dc
b
a2
c
-10
0
10
-23.3 -17.8 -12.2
2.46 2.66 2.90
2.41 2.59 2.80
2.46 2.66 2.90
2.41 2.59 2.81
20
-6.7
3.17
3.05
3.17
3.06
30
-1.1
3.47
3.33
3.47
3.35
40
4.4
3.81
3.64
3.81
3.67
45
7.2
3.99
3.82
3.99
3.84
10
12
Main winding
11
13
Start winding
Thermostat
14
Motor protector
-10
0
10
-23.3 -17.8 -12.2
3.82 4.44 5.02
4.43 5.09 5.68
3.26 3.78 4.27
1.10 1.26 1.41
20
-6.7
5.54
6.19
4.71
1.54
30
-1.1
6.01
6.60
5.10
1.64
40
4.4
6.41
6.91
5.42
1.72
45
7.2
6.58
7.04
5.56
1.75
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
preliminary data
120 (49)
135 (58)
Accessories
Devices
Starting relay (Klixon incl.)
Klixon
Fig.
a2
TF4CLX
117U4148
MRP36EN-6
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities
September 2002
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
117U5025
118-1945
118-1948
118-1944
CF.52.E2.22
CK.54.B6.02
September 2002
75
TFS4.5CLX
LBP Compressor
R404A/R507
115-127V 60Hz
Data Sheet (Replaces CF.52.D1.22)
General
TFS4.5CLX
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
102U
TFS4.5CLX
Code number
Lilac stripe
R404A
SUCTION R507
CONNECTOR
102U2103
2103
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
LBP
F (C)
V/Hz
TFS4CLX
115V-60Hz
1PH
Motor type
CSIR
F (C)
THERMALLY
PROTECTED
110 (43)
Comp. cooling at
110F (43C)
F1
S
O
F1
F2
Design
3
14.0 (400)
fl.oz. (cm3)
57.3 (1690)
lbs. (kg)
17.9 (8.1)
Motor
4.02"(102)
watt
225
20.0
20.0
8246
8.90"(226)
6.93"(176)
in. (mm) A
6.81 (173)
6.65 (169)
Suction connector
Process connector
Discharge connector
4.13"(105)
4.21"(107)
0.75"(19)
6.50"(165)
0.63"(16)
0.14"(3.6)
2.76"(70)
A B
4.13"(105)
UL984/CSA-C22.2
Dimensions
31.5
28
2.6/3.8
Approvals
pcs.
3.78"(96)
4.61"(117)
30
Motor size
Compressors on a pallet
45
(29)
9.5 (280)
oz. (g)
0.29 (4.63)
125
5.35"(136)
fl.oz. (cm3)
51 20
cu.in. (cm )
Oil quantity
6.18"(157)
Displacement
Approval mark
2.34"(59.5)
2.60" (66)
1.14"
2.80"(71)
Voltage range
4.00"(101.6)
8405-2
Application
Height
8405
Compressor
6.70"(170)
7.01"(178)
8.03"(204)
September 2002
76
CF.52.D2.22
CK.54.B6.02
September 2002
Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
CECOMAF
-40
-40
332
407
100
-30
-34.4
494
569
141
-20
-28.9
690
769
192
-13
-25
851
933
233
-10
-23.3
926
1010
252
0
-17.8
1207
1298
325
10
-12.2
1539
1637
410
20
-6.7
1930
2034
509
-49
-45
100
113
109
-40
-40
130
135
134
-30
-34.4
161
160
160
-20
-28.9
194
186
187
-13
-25
217
206
207
-10
-23.3
228
215
217
0
-17.8
266
250
251
10
-12.2
310
291
292
-49
-45
2.18
2.23
2.21
-40
-40
2.26
2.29
2.28
-49
-45
2.10
2.55
0.62
-40
-40
2.56
3.01
0.75
EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
CECOMAF
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz
-30
-34.4
2.40
2.39
2.39
-20
-28.9
2.60
2.55
2.55
-13
-25
2.76
2.70
2.70
-10
-23.3
2.84
2.76
2.77
-20
-28.9
3.56
4.14
1.03
-13
-25
3.91
4.53
1.13
-10
-23.3
4.06
4.69
1.17
a2
20
-6.7
360
340
342
8226
dc
A
0
-17.8
3.14
3.03
3.04
10
-12.2
3.48
3.34
3.35
20
-6.7
3.88
3.70
3.72
watt
0
-17.8
4.53
5.20
1.29
10
-12.2
4.97
5.63
1.40
20
-6.7
5.36
5.98
1.49
b
a2
c
10
12
Main winding
11
13
Start winding
Thermostat
14
Motor protector
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
120 (49)
135 (58)
Accessories
Devices
Starting relay (Klixon incl.)
Klixon
Fig.
a2
TFS4.5CLX
117U4148
MRP36EN-6
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1945
118-1948
118-1944
September 2002
117U5025
CF.52.D2.22
CK.54.B6.02
September 2002
77
NF5.5CLX
LBP/MBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
NF5.5CLX
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
105F1621
Copper-plated steel
Rubber plugs
105F1622
Copper
Rubber plugs
Application
105F
NF5.5CLX
R404A
SUCTION R507
CONNECTOR
Lilac stripe
1621
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
8406-3
Compressor
LBP/MBP
NF5.5CLX
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F2
THERMALLY
S
O
F1
F2
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8406-4
Application
10.8 (320)
oz. (g)
14.0 (400)
fl.oz. (cm3)
76.9 (2280)
lbs. (kg)
22.2 (10.0)
0.37 (6.13)
4.45"(113)
310
30.0
30.0
1.9/6.6
Approvals
UL984/CSA-C22.2
A B
15
9.92"(252)
8.03"(204)
6.70"(170)
Dimensions
B
8.00 (203)
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
8367
7.76 (197)
Suction connector
1.38"(35)
in. (mm) A
5.20"(132)
4.00"(101.6)
2.76"(70)
Height
35
4.04"(102.5)
watt
E
C
25
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
47
8.10"(205)
Motor
27
51
(54)
fl.oz. (cm3)
3.01"(78)
Oil quantity
2.97"(75.5)
cu.in. (cm3)
2.13"
Displacement
6.54"(166)
2.83"(72)
2.34" (59.5)
Design
0.75"(19)
0.63"(16)
0.38"(9.7)
80
6.50"(165)
7.32"(186)
September 2002
78
CF.53.G1.22
CK.54.B6.02
September 2002
Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900
-40
-40
463
566
396
140
-30
-20
-34.4 -28.9
675
933
789 1057
577
797
196
264
-13
-10
0
10
20
-25 -23.3 -17.8 -12.2 -6.7
1145 1245 1620 2066 2593
1276 1378 1759 2206 2728
977 1062 1380 1758 2204
319
345
441 554
685
30
40
-1.1
4.4
3211 3931
3331 4025
2724 3328
836 1010
-49
-45
142
155
142
153
-40
-40
179
185
179
185
-30
-20
-34.4 -28.9
218
257
219
253
218
257
219
254
-13
-25
285
277
285
279
-49
-45
3.32
3.35
3.32
3.35
-40
-40
3.42
3.43
3.42
3.43
-30
-20
-34.4 -28.9
3.57 3.75
3.54 3.69
3.57 3.75
3.55 3.70
-49
-45
2.13
2.58
1.28
0.64
-40
-40
2.59
3.05
2.22
0.76
-30
-20
-34.4 -28.9
3.10 3.63
3.60 4.18
2.65 3.10
0.89 1.04
EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz
-13
-25
3.90
3.82
3.90
3.83
c
a2
watt
-10
0
10
-23.3 -17.8 -12.2
297
338
382
288
324
362
297
338
382
290
327
366
20
-6.7
428
404
428
408
30
-1.1
477
449
477
454
40
4.4
530
498
530
504
45
7.2
4333
4408
3663
1106
8226
45
7.2
559
524
559
530
dc
b
a2
c
-10
0
10
-23.3 -17.8 -12.2
3.96 4.21 4.49
3.88 4.09 4.34
3.96 4.21 4.49
3.89 4.11 4.37
20
-6.7
4.81
4.63
4.81
4.65
30
-1.1
5.16
4.94
5.16
4.98
40
4.4
5.54
5.29
5.54
5.33
45
7.2
5.74
5.48
5.74
5.52
10
12
Start winding
11
13
Thermostat
Main winding
14
(pos.1)
Motor protector
-10
0
10
-23.3 -17.8 -12.2
4.19 4.79 5.41
4.79 5.43 6.09
3.57 4.08 4.61
1.19 1.35 1.51
20
-6.7
6.06
6.76
5.15
1.68
30
-1.1
6.73
7.43
5.71
1.84
40
4.4
7.41
8.08
6.27
2.01
45
7.2
7.75
8.40
6.55
2.08
8408
EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60
a2
b
a2
7
Accessories
L
2
Devices
Fig.
NF5.5CLX
a2
117U4061
MRP30AEN-6
Klixon
Starting capacitor 280 F
117U5025
b
d
dc
(pos.1)
117U1021
117U0349
117U0349
b
(pos.2)
117U1024
in.(mm)
0.63 (16)
0.75 (19)
0.63 (16)
in.(mm)
0.63 (16)
0.63 (16)
0.63 (16)
September 2002
Main winding
11
10
4
13
12
c
Start winding
5
14
M
6
Cover (standard)
Cord relief
Cord relief for capacitor
(pos.2)
Motor protector
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
120 (49)
135 (58)
118-1945
118-1948
118-1944
118-1917
118-1918
118-1919
CF.53.G1.22
CK.54.B6.02
September 2002
79
NF7CLX
LBP/MBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
NF7CLX
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
105F1721
Copper-plated steel
Rubber plugs
105F1722
Copper
Rubber plugs
Application
105F
NF7CLX
R404A
SUCTION R507
CONNECTOR
Lilac stripe
1722
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
8406
Compressor
LBP/MBP
NF7CLX
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F2
THERMALLY
S
O
F1
F2
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8406-2
Application
10.8 (320)
oz. (g)
14.0 (400)
fl.oz. (cm3)
76.9 (2280)
lbs. (kg)
22.2 (10.0)
0.68 (7.27)
4.45"(113)
330
28.0
28.0
1.7/5.4
Approvals
UL984/CSA-C22.2
A B
15
9.92"(252)
8.03"(204)
6.70"(170)
Dimensions
B
8.00 (203)
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
8367
7.76 (197)
Suction connector
1.38"(35)
in. (mm) A
5.20"(132)
4.00"(101.6)
2.76"(70)
Height
35
4.04"(102.5)
watt
E
C
25
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
47
8.10"(205)
Motor
27
51
(54)
fl.oz. (cm3)
3.01"(78)
Oil quantity
2.97"(75.5)
cu.in. (cm3)
2.13"
Displacement
6.54"(166)
2.83"(72)
2.34" (59.5)
Design
0.75"(19)
0.63"(16)
0.38"(9.7)
80
6.50"(165)
7.32"(186)
September 2002
80
CF.53.H1.22
CK.54.B6.02
September 2002
Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900
-40
-40
531
674
454
166
-30
-20
-34.4 -28.9
805 1137
961 1306
688
971
238
326
-13
-10
0
-25 -23.3 -17.8
1410 1539 2021
1588 1719 2209
1203 1312 1722
397
430
553
10
20
-12.2 -6.7
2595 3274
2785 3457
2209 2782
699
868
30
40
45
-1.1
4.4
7.2
4069 4996 5513
4234 5127 5620
3452 4229 4661
1063 1286 1409
-49
-45
176
191
176
189
-40
-40
221
229
221
229
-30
-20
-34.4 -28.9
270
318
271 313
270
318
271 314
-13
-25
353
343
353
345
-49
-45
3.60
3.65
3.60
3.64
-40
-40
3.75
3.76
3.75
3.76
-30
-20
-34.4 -28.9
3.96 4.22
3.93 4.14
3.96 4.22
3.93 4.15
-49
-45
1.85
2.39
1.58
0.59
-40
-40
2.41
2.94
2.06
0.72
-30
-20
-34.4 -28.9
2.98 3.57
3.54 4.17
2.55 3.05
0.88 1.04
EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz
-13
-25
4.43
4.32
4.43
4.33
a2
watt
-10
0
10
-23.3 -17.8 -12.2
368
419
472
356
401 448
368
419
472
358
404
452
20
-6.7
529
499
529
504
30
-1.1
590
555
590
561
40
4.4
656
616
656
623
8226
45
7.2
691
649
691
656
dc
b
a2
c
-10
0
10
-23.3 -17.8 -12.2
4.53 4.88 5.29
4.40 4.71 5.07
4.53 4.88 5.29
4.42 4.74 5.10
20
-6.7
5.74
5.47
5.74
5.51
30
-1.1
6.24
5.93
6.24
5.97
40
4.4
6.78
6.43
6.78
6.48
45
7.2
7.07
6.70
7.07
6.76
10
12
Start winding
11
13
Thermostat
Main winding
14
(pos.1)
Motor protector
-10
0
10
-23.3 -17.8 -12.2
4.18 4.83 5.50
4.83 5.52 6.22
3.57 4.11 4.68
1.20 1.37 1.54
20
-6.7
6.19
6.92
5.26
1.72
30
-1.1
6.90
7.63
5.85
1.89
40
4.4
7.61
8.32
6.45
2.07
45
7.2
7.97
8.66
6.74
2.15
8408
EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60
a2
b
a2
7
Accessories
L
2
Devices
Fig.
NF7CLX
a2
117U4129
Main winding
11
10
N
4
13
12
c
Start winding
MRT22AFZ-6
Klixon
Starting capacitor 320 F
117U5022
Cover (standard)
Cord relief
Cord relief for capacitor
b
d
dc
(pos.1)
117U1021
117U0349
117U0349
b
(pos.2)
117U1024
in.(mm)
0.63 (16)
0.75 (19)
0.63 (16)
in.(mm)
0.63 (16)
0.63 (16)
0.63 (16)
September 2002
14
(pos.2)
Motor protector
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
120 (49)
135 (58)
118-1945
118-1948
118-1944
118-1917
118-1918
118-1919
CF.53.H1.22
CK.54.B6.02
September 2002
81
SC10CL
LBP/MBP Compressor
R404A/R507
115V 60Hz
Data Sheet (Replaces CF.54.Q2.22)
General
Compressor
104L
SC10CL
SC10CL
Application
104L1503
R404A
R507
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/MBP
Barcode on
white background
Green background
1503
DANFOSS COMPRESSORS
CSIR
SC10CL
115V-60Hz
1PH
110 (43)
Comp. cooling at
110F (43C)
F2
THERMALLY
S
O
F1
Design
Displacement
cu.in. (cm3)
0.63 (10.29)
Oil quantity
fl.oz. (cm3)
18.6 (550)
oz. (g)
45.8 (1300)
51.1 (1510)
27.7 (12.6)
lbs. (kg)
Motor
Motor size
watt
540
41.9
41.9
4.21"(107)
4.21"(107)
4.53"(115)
E
B A
B1
8.00 (203)
B1
7.20 (183)
B2
3.93 (100)
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
pcs.
80
0.63"(16)
10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)
5"(127)
6.50"(165)
7.32"(186)
82
CF.54.Q3.22
CK.54.B6.02
0.75"(19)
0.38"(9.7)
2.76"(70)
5.91"(150)
B2
0.12"(3)
8.23 (209)
5"(127)
4"(101.6)
1.38"(35)
in. (mm) A
Suction connector
September 2002
8.58"(218)
UL984/CSA-C22.2
Dimensions
Compressors on a pallet
37
37
1.0/4.3
Approvals
Height
F2
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
5.94"(151)
2.17"(55)
8323-2
F (C)
2.48"(63)
2.48"(63)
2.17"(55)
Motor type
8323
Lilac stripe
Application
8324
September 2002
Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900
-30
-34.4
624
926
533
223
-20
-28.9
1154
1422
986
349
-13
-25
1568
1818
1338
450
-10
-23.3
1758
2001
1500
497
0
-17.8
2453
2681
2091
668
10
-12.2
3261
3477
2775
869
20
-6.7
4200
4405
3570
1102
30
-1.1
5293
5483
4491
1372
40
4.4
6563
6727
5556
1682
41
5
6701
6861
5671
1716
10
-12.2
649
608
649
616
20
-6.7
719
664
719
674
30
-1.1
785
720
785
732
40
4.4
850
778
850
790
41
5
856
784
856
796
45
7.2
882
808
882
821
10
-12.2
7.37
7.08
7.37
7.13
20
-6.7
7.91
7.50
7.91
7.57
30
-1.1
8.44
7.91
8.44
8.00
40
4.4
8.95
8.31
8.95
8.41
41
5
9.00
8.34
9.00
8.45
45
7.2
9.21
8.50
9.21
8.61
-40
-40
162
240
162
230
-30
-34.4
285
332
285
327
-20
-28.9
393
413
393
412
-13
-25
461
464
461
465
-10
-23.3
488
484
488
487
watt
0
-17.8
573
548
573
554
-40
-40
4.52
4.83
4.52
4.79
-30
-34.4
5.11
5.30
5.11
5.28
-20
-28.9
5.69
5.77
5.69
5.76
-13
-25
6.09
6.08
6.09
6.09
-10
-23.3
6.26
6.22
6.26
6.23
-40
-40
0.91
2.08
0.77
0.49
-30
-34.4
2.19
2.79
1.87
0.68
-20
-28.9
2.94
3.44
2.51
0.85
-13
-25
3.40
3.92
2.90
0.97
-10
-23.3
3.60
4.13
3.07
1.02
EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900
45
7.2
7272
7417
6148
1854
0
-17.8
6.82
6.66
6.82
6.69
10
-12.2
5.02
5.72
4.27
1.41
20
-6.7
5.84
6.63
4.96
1.63
30
-1.1
6.74
7.61
5.72
1.87
40
4.4
7.73
8.65
6.54
2.13
41
5
7.83
8.75
6.63
2.15
45
7.2
8.25
9.18
6.97
2.26
b
8222
a2
120 (49)
135 (58)
Accessories
Devices
Fig.
SC10CL
Starting relay
a2
117U6020
Cover
103N2008
117U5023
Cord relief
103N1004
c
11
10
12
13
14
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.Q3.22
CK.54.B6.02
Start winding
Main winding
Winding protector
September 2002
83
SC12CL
LBP Compressor
R404A/R507
115V 60Hz
Data Sheet (Replaces CF.54.U1.22)
General
Compressor
104L
SC12CL
SC12CL
Application
104L1603
R404A
R507
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP
Barcode on
white background
Green background
1603
DANFOSS COMPRESSORS
CSIR
SC12CL
115V-60Hz
1PH
110 (43)
Comp. cooling at
110F (43C)
F2
THERMALLY
S
O
F1
Design
Displacement
cu.in. (cm3)
0.78 (12.87)
Oil quantity
fl.oz. (cm3)
18.6 (550)
oz. (g)
45.8 (1300)
51.1 (1510)
27.7 (12.6)
lbs. (kg)
Motor
Motor size
watt
540
41.9
41.9
4.21"(107)
4.53"(115)
E
B A
8.00 (203)
B1
7.20 (183)
B2
3.93 (100)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
pcs.
80
0.63"(16)
10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)
5"(127)
6.50"(165)
7.32"(186)
84
CF.54.U2.22
CK.54.B6.02
0.75"(19)
0.38"(9.7)
2.76"(70)
5.91"(150)
B2
0.12"(3)
8.23 (209)
5"(127)
4"(101.6)
1.38"(35)
in. (mm) A
0.320-0.327 (8.20.09)
September 2002
8.58"(218)
B1
Compressors on a pallet
4.21"(107)
UL984/CSA-C22.2
Dimensions
Suction connector
37
37
1.0/4.3
Approvals
Height
F2
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
5.94"(151)
2.17"(55)
8323-4
F (C)
2.48"(63)
2.48"(63)
2.17"(55)
Motor type
8323-3
Lilac stripe
Application
8324
September 2002
Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900
-30
-34.4
842
1229
297
-20
-28.9
1577
1871
463
-13
-25
2127
2366
590
-10
-23.3
2374
2592
648
0
-17.8
3255
3414
857
10
-12.2
4246
4356
1095
0
-17.8
739
720
723
10
-12.2
848
822
826
-40
-40
212
322
308
-30
-34.4
374
436
429
-20
-28.9
510
535
533
-13
-25
595
599
600
watt
-10
-23.3
629
627
628
-40
-40
4.92
5.32
5.26
EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900
-30
-34.4
5.44
5.69
5.64
-20
-28.9
6.08
6.17
6.15
-13
-25
6.60
6.59
6.58
b
8222
a2
d
-10
-23.3
6.84
6.78
6.79
0
-17.8
7.73
7.52
7.55
10
-12.2
8.74
8.38
8.43
-30
-34.4
2.25
2.82
0.69
-20
-28.9
3.09
3.50
0.87
-13
-25
3.58
3.95
0.98
-10
-23.3
3.77
4.14
1.03
0
-17.8
4.40
4.74
1.18
10
-12.2
5.01
5.30
1.33
11
10
12
13
14
Start winding
Main winding
Winding protector
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz
ASHRAE LBP
130F (54.4C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
ASHRAE LBP*
110F (43.3C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60
EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60
120 (49)
135 (58)
Accessories
Devices
Fig.
SC12CL
Starting relay
a2
117U6020
Cover
103N2008
117U5023
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.U2.22
CK.54.B6.02
September 2002
85
SC12CLX.2
LBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
Compressor
104L
SC12CLX.2
SC12CLX.2
Application
104L1696
R404A
R507
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP
Barcode on
white background
Green background
1696
DANFOSS COMPRESSORS
CSIR
SC12CLX.2
115V-60Hz
1PH
110 (43)
Comp. cooling at
110F (43C)
F2
THERMALLY
S
O
F1
Design
Displacement
cu.in. (cm3)
0.78 (12.87)
Oil quantity
fl.oz. (cm3)
18.6 (550)
oz. (g)
45.8 (1300)
51.1 (1510)
27.7 (12.6)
lbs. (kg)
Motor
Motor size
watt
540
41.9
41.9
4.21"(107)
4.53"(115)
E
B A
8.00 (203)
B1
7.20 (183)
B2
3.93 (100)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
pcs.
80
0.63"(16)
10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)
5"(127)
6.50"(165)
7.32"(186)
86
CJ.54.N1.22
CK.54.B6.02
0.75"(19)
0.38"(9.7)
2.76"(70)
5.91"(150)
B2
0.12"(3)
8.23 (209)
5"(127)
4"(101.6)
1.38"(35)
in. (mm) A
0.320-0.327 (8.20.09)
September 2002
8.58"(218)
B1
Compressors on a pallet
4.21"(107)
UL984/CSA-C22.2
Dimensions
Suction connector
37
37
1.0/4.3
Approvals
Height
F2
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
5.94"(151)
2.17"(55)
8464-4
F (C)
2.48"(63)
2.48"(63)
2.17"(55)
Motor type
8464
Lilac stripe
Application
8324
September 2002
Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900
-30
-34.4
950
240
1500
380
-20
-28.9
-13
-25
2540
645
-10
-23.3
2550
2730
690
0
-17.8
10
-12.2
-40
-40
-30
-34.4
380
360
460
450
-20
-28.9
-13
-25
-10
-23.3
617
616
616
585
585
20
-6.7
5250
5350
1290
watt
0
-17.8
10
-12.2
20
-6.7
930
-40
-40
-30
-34.4
5.35
5.30
6.10
6.00
EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900
-20
-28.9
-13
-25
6.65
6.65
-10
-23.3
6.95
6.90
6.90
b
8222
a2
0
-17.8
10
-12.2
20
-6.7
9.50
-30
-34.4
2.50
0.66
3.26
0.84
-20
-28.9
-13
-25
4.34
1.10
-10
-23.3
4.13
4.43
1.12
11
10
0
-17.8
10
-12.2
12
13
14
20
-6.7
5.64
Start winding
Main winding
Winding protector
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz
ASHRAE LBP
130F (54.4C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
preliminary data
ASHRAE LBP*
110F (43.3C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60
EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60
120 (49)
135 (58)
Accessories
Devices
Fig.
SC12CLX.2
Starting relay
a2
117U6020
Cover
103N2008
117U5023
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CJ.54.N1.22
CK.54.B6.02
September 2002
87
SC12MLX
MBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
Compressor (CU-plated steel connectors)
SC12MLX
Codenumber
104L1606
104L
SC12MLX
Application
R404A
R507
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
MBP
Barcode on
white background
Green background
1606
DANFOSS COMPRESSORS
95 - 135 /60
CSIR
F (C)
SC12MLX
115V-60Hz
1PH
110 (43)
Comp. cooling at
110F (43C)
F2
Design
cu.in. (cm3)
0.78 (12.86)
fl.oz. (cm3)
45.5 (1300)
49.4 (1460)
30.2 (13.7)
lbs. (kg)
37
37
4.21"(107)
Motor
D
watt
755
53
53
4.21"(107)
4.53"(115)
E
B A
B1
B2
0.12"(3)
UL984/CSA-C22.2
8.62 (219)
8.39 (213)
B1
7.60 (193)
B2
4.33 (110)
Suction connector
Process connector
Discharge connector
0.252-0.259 (6.50.09)
0.63"(16)
10.43"(265)
8.03"(204)
7.01"(178)
6.69"(170)
88
0.38"(9.7)
60
5"(127)
6.50"(165)
7.32"(186)
May 2002
0.75"(19)
2.76"(70)
5.91"(150)
in. (mm) A
5"(127)
4"(101.6)
1.38"(35)
Dimensions
Compressors on a pallet
8.58"(218)
0.7/2.9
Approvals
Height
Approval mark
20.3 (600)
oz. (g)
Motor size
THERMALLY
PROTECTED
2.48"(63)
Oil quantity
F2
2.34" (59.5)
Displacement
S
O
F1
5.94"(151)
2.17"(55)
2.17"(55)
8459-4
Motor type
8459-7
Lilac stripe
Application
CJ.54.J1.22
CK.54.B6.02
8432
September 2002
Capacity
Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900
0
-17.8
2640
864
10
-12.2
3435
1103
20
-6.7
4391
1388
30
-1.1
5527
1725
40
4.4
6865
2118
41
5
7011
2160
45
7.2
7616
2337
-10
-23.3
581
589
0
-17.8
676
662
10
-12.2
770
735
20
-6.7
865
811
30
-1.1
960
890
40
4.4
1058
973
41
5
1067
982
45
7.2
1107
1017
-10
-23.3
7.93
7.94
EER / COP
Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900
0
-17.8
8.50
8.38
10
-12.2
9.13
8.88
20
-6.7
9.83
9.44
30
-1.1
10.58
10.06
41
5
11.48
10.81
45
7.2
11.82
11.10
Test conditions
Condensing temperature
Suction gas temperature
Ambient temperature
Liquid temperature
Cooling
V/Hz
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
0
-17.8
3.90
1.31
10
-12.2
4.46
1.50
20
-6.7
5.08
1.71
ASHRAE MBP
130F (54.4C)
95F (35C)
90F (32C)
115F (46C)
Fan F2
115/60
30
-1.1
5.76
1.94
8433
40
4.4
11.39
10.74
40
4.4
6.49
2.18
41
5
6.57
2.20
45
7.2
6.88
2.30
EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60
watt
a2
b
a2
Start winding
c
Main winding
R
Thermostat
Motor protector
M
120 (49)
135 (58)
Accessories
Devices
Fig.
Starting relay
a2
117-7441
117U5028
Cover
Protector
Protector holder
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
SC12MLX
(117U1021)
parts of
compressor
(117U3212)
(117U0438)
118-1917
118-1918
118-1919
CJ.54.J1.22
CK.54.B6.02
May 2002
89
SC15CLX.2
LBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
Compressor (CU-plated steel connectors)
SC15CLX.2
Codenumber
104L
SC15CLX.2
Application
104L1853
R404A
R507
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP
Barcode on
white background
Green background
1853
DANFOSS COMPRESSORS
CSIR
110F (43C)
F2
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
18.6 (550)
oz. (g)
45.5 (1300)
49.4 (1460)
30.2 (13.7)
0.93 (15.28)
lbs. (kg)
Motor
Motor size
watt
755
53
53
S
O
F1
F2
5.94"(151)
2.17"(55)
4.21"(107)
E
B A
B1
8.62 (219)
8.39 (213)
B1
7.60 (193)
B2
4.33 (110)
Suction connector
Process connector
Discharge connector
0.63"(16)
10.43"(265)
8.03"(204)
7.01"(178)
6.69"(170)
0.252-0.259 (6.50.09)
60
5"(127)
6.50"(165)
7.32"(186)
90
CJ.54.I1.22
CK.54.B6.02
0.75"(19)
0.38"(9.7)
2.76"(70)
5.91"(150)
Compressors on a pallet
B2
0.12"(3)
in. (mm) A
5"(127)
4"(101.6)
1.38"(35)
Height
August 2002
8.58"(218)
UL984/CSA-C22.2
Dimensions
Approval mark
4.21"(107)
4.53"(115)
0.7/2.9
Approvals
THERMALLY
PROTECTED
37
37
8464-2
SC15CLX.2
115V-60Hz
1PH
110 (43)
2.48"(63)
F (C)
Comp. cooling at
2.34" (59.5)
2.17"(55)
Motor type
8464
Lilac stripe
Application
8432
September 2002
Capacity
Evap. temp in F
Evap. temp in C
ASHRAE LBP
ASHRAE LBP*
EN 12900
-30
-34.4
989
1605
387
-20
-28.9
1964
2473
611
-13
-25
2671
3106
773
-10
-23.3
2980
3384
845
0
-17.8
4037
4337
1088
10
-12.2
5134
5331
1342
20
-6.7
6270
6364
1604
0
-17.8
839
804
809
10
-12.2
944
890
898
20
-6.7
1046
983
991
10
-12.2
10.42
10.18
10.24
20
-6.7
11.23
10.87
10.95
-40
-40
231
356
341
-30
-34.4
428
499
491
-20
-28.9
589
616
614
-13
-25
686
687
688
-10
-23.3
724
715
717
-40
-40
6.70
7.03
7.00
EER / COP
Evap. temp in F
Evap. temp in C
ASHRAE LBP
ASHRAE LBP*
EN 12900
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz
-30
-34.4
7.40
7.62
7.61
-20
-28.9
8.13
8.23
8.24
-13
-25
8.65
8.67
8.69
-10
-23.3
8.87
8.86
8.88
-30
-34.4
2.31
3.22
0.79
-20
-28.9
3.33
4.01
0.99
ASHRAE LBP
130F (54.4C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
-13
-25
3.90
4.52
1.12
-10
-23.3
4.12
4.73
1.18
ASHRAE LBP*
110F (43.3C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60
8433
0
-17.8
4.81
5.40
1.34
10
-12.2
5.44
5.99
1.49
20
-6.7
6.00
6.48
1.62
a2
b
a2
0
-17.8
9.64
9.51
9.55
watt
Start winding
c
Main winding
R
Thermostat
Motor protector
M
EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60
120 (49)
135 (58)
Accessories
Devices
Fig.
Starting relay
a2
117-7441
117U5028
Cover
Protector
Protector holder
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
SC15CLX.2
(117U1021)
parts of
compressor
(117U3212)
(117U0438)
118-1917
118-1918
118-1919
CJ.54.I1.22
CK.54.B6.02
August 2002
91
SC15MLX
MBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
Compressor (CU-plated steel connectors)
SC15MLX
Codenumber
104L1805
104L
SC15MLX
Application
R404A
R507
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
MBP
Barcode on
white background
Green background
1805
DANFOSS COMPRESSORS
8459-5
Lilac stripe
Application
SC15MLX
115V-60Hz
1PH
CSIR/CSR
F (C)
110 (43)
Comp. cooling at
110F (43C)
F2
S
O
F1
F2
Design
cu.in. (cm3)
20.3 (600)
oz. (g)
45.5 (1300)
49.4 (1460)
30.9 (14.0)
lbs. (kg)
37
37
Motor
Motor size
watt
965
64
4.21"(107)
4.21"(107)
4.53"(115)
0.6/2.7
Approvals
8.58"(218)
64
UL984/CSA-C22.2
B A
B1
8.62 (219)
8.39 (213)
B1
7.60 (193)
B2
4.33 (110)
Suction connector
Process connector
Discharge connector
Compressors on a pallet
pcs.
0.252-0.259 (6.50.09)
60
B2
0.63"(16)
10.43"(265)
8.03"(204)
7.01"(178)
6.69"(170)
5"(127)
6.50"(165)
7.32"(186)
92
CJ.54.E1.22
CK.54.B6.02
0.75"(19)
0.38"(9.7)
2.76"(70)
5.91"(150)
in. (mm) A
0.12"(3)
Height
5"(127)
4"(101.6)
1.38"(35)
Dimensions
September 2002
2.48"(63)
Approval mark
0.93 (15.28)
fl.oz. (cm3)
Oil quantity
THERMALLY
PROTECTED
2.34" (59.5)
Displacement
5.94"(151)
2.17"(55)
2.17"(55)
8459-6
Motor type
8432
September 2002
Capacity
Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900
0
-17.8
3049
998
10
-12.2
3967
1274
20
-6.7
5070
1603
30
-1.1
6383
1992
40
4.4
7928
2446
41
5
8096
2495
45
7.2
8795
2698
-10
-23.3
719
729
0
-17.8
837
819
10
-12.2
954
910
20
-6.7
1070
1004
30
-1.1
1188
1102
40
4.4
1309
1205
41
5
1321
1216
-10
-23.3
9.88
9.88
0
-17.8
10.59
10.43
EER / COP
Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900
10
-12.2
11.37
11.05
20
-6.7
12.24
11.75
30
-1.1
13.17
12.52
40
4.4
14.19
13.37
41
5
14.29
13.46
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz
0
-17.8
3.64
1.22
10
-12.2
4.16
1.40
ASHRAE MBP
130F (54.4C)
95F (35C)
90F (32C)
115F (46C)
Fan F2
115/60
20
-6.7
4.74
1.60
30
-1.1
5.37
1.81
40
4.4
6.06
2.03
41
5
6.13
2.05
8460
45
7.2
14.72
13.82
45
7.2
1371
1259
45
7.2
6.42
2.14
EN 12900/CECOMAF
45C (113F)
32C (90F)
32C (90F)
45C (113C)
Fan F2
115/60
watt
a2
b
a2
Start winding
e
5
Main winding
R
Thermostat
Motor protector
M
(pos.1)
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
preliminary data
120 (49)
135 (58)
8433
Accessories
Devices
Fig.
CSR (pos.1)
117-7114
Devices
Fig.
Starting relay
a2
117-7441
117U5028
Cover
Protector
Protector holder
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
a2
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
b
a2
Start winding
c
Main winding
R
(117U1021)
parts of
compressor
(117U3212)
Thermostat
(117U0438)
118-1917
118-1918
118-1919
CJ.54.E1.22
CK.54.B6.02
Motor protector
(pos.2)
September 2002
93
SC10DL
MBP/HBP Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.V1.02)
General
SC10DL
Code number
104L2525
104L
SC10DL
Application
R404A
R407C R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
MBP/HBP
Barcode on
white background
-15 to 15
Yellow background
2525
DANFOSS COMPRESSORS
8306
Compressor
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
600
1300
cm3
1410
kg
13.1
204
178
170
16
watt
385
14.8
14.8
5.0/13.7
Approvals
70
150
Motor size
EN 60 335-2-34
127
165
186
218
D
Dimensions
Suction connector
mm
location/I.D. mm
209
203
B1
183
B2
100
8.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
Height
19
9.7
127
101.6
35
Motor
37
37
107
September 2002
94
CF.54.V2.02
CK.54.B6.02
107
115
55
63
10.29
8258
September 2002
-15
480
-10
636
-5
821
watt
0
1039
5
1293
7.2
1417
10
1588
15
1927
c
Capacity (ASHRAE)
Comp.\C
SC10DL
-15
515
-10
682
watt
-5
881
0
1114
5
1388
7.2
1522
10
1706
15
2073
b
8222
Power consumption
Comp.\C
SC10DL
-15
346
-10
394
watt
-5
437
0
476
5
510
7.2
524
10
540
15
568
a2
d
Current consumption
Comp.\C
SC10DL
-15
2.50
-10
2.66
A
-5
2.81
0
2.95
5
3.08
7.2
3.14
10
3.20
15
3.31
c
11
10
-15
1.39
W/W
-10
1.61
-5
1.88
0
2.18
5
2.54
7.2
2.71
10
2.94
-10
1.73
-5
2.01
0
2.34
5
2.72
7.2
2.91
10
3.16
COP (ASHRAE)
Comp.\C
SC10DL
-15
1.49
15
3.40
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
no subcooling
15
3.65
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC10DL
Starting relay
a2
117U6005
Cover
103N2009
Starting capacitor 80 F
117U5017
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.V2.02
CK.54.B6.02
September 2002
95
SC12DL
MBP/HBP Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.W1.02)
General
SC12DL
Code number
104L2625
104L
SC12DL
Application
R404A
R407C R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
MBP/HBP
Barcode on
white background
-15 to 15
Yellow background
2625
DANFOSS COMPRESSORS
8306-3
Compressor
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm 3
Oil quantity
cm3
600
1300
cm3
1460
kg
13.6
204
178
170
16
watt
495
18.6
18.6
3.7/14.1
Approvals
70
150
Motor size
EN 60335-2-34
127
165
186
218
D
Dimensions
A
219
213
B1
193
B2
110
location/I.D. mm
10.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Suction connector
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
mm
Height
19
9.7
127
101.6
35
Motor
37
37
107
September 2002
96
CF.54.W2.02
CK.54.B6.02
107
115
55
63
12.87
8258
September 2002
-15
632
-10
831
-5
1065
watt
0
1340
5
1660
7.2
1817
10
2031
15
2456
c
Capacity (ASHRAE)
Comp.\C
SC12DL
-15
677
-10
891
watt
-5
1143
0
1438
5
1783
7.2
1951
10
2182
15
2642
b
8222
Power consumption
Comp.\C
SC12DL
-15
456
-10
512
watt
-5
562
0
606
5
643
7.2
658
10
675
15
700
a2
d
Current consumption
Comp.\C
SC12DL
-15
3.11
-10
3.31
A
-5
3.49
0
3.65
5
3.79
7.2
3.85
10
3.91
15
4.01
c
11
10
-15
1.39
W/W
-10
1.62
-5
1.89
0
2.21
5
2.58
7.2
2.76
10
3.01
-10
1.74
-5
2.03
0
2.37
5
2.77
7.2
2.97
10
3.23
COP (ASHRAE)
Comp.\C
SC12DL
-15
1.48
15
3.51
12
13
14
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
EN 12900/CECOMAF
45C
32C
no subcooling
15
3.77
Start winding
Main winding
Winding protector
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC12DL
Starting relay
a2
117U6019
Cover
103N2009
Starting capacitor 80 F
117U5017
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
118-1917
118-1918
118-1919
CF.54.W2.02
CK.54.B6.02
September 2002
97
SC15DL
MBP/HBP Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.X1.02)
General
SC15DL
Code number
104L2856
104L
SC15DL
Application
R404A
R407C R507
Lilac stripe
Approvals
Application
Application
Evaporating temperature range
Voltage range
C
V/Hz
MBP/HBP
Barcode on
white background
-15 to 15
Yellow background
2856
DANFOSS COMPRESSORS
8306-5
Compressor
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm 3
Oil quantity
cm3
600
1300
cm3
1460
kg
13.5
204
178
170
16
watt
550
21.8
21.8
3.5/12.2
Approvals
70
150
Motor size
EN 60 335-2-34
127
165
186
218
D
Dimensions
A
219
213
B1
193
B2
110
location/I.D. mm
10.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Suction connector
pcs.
E
B A
B1
B2
255
80
55
63
151
Compressors on a pallet
mm
Height
19
9.7
127
101.6
35
Motor
37
37
107
September 2002
98
CF.54.X2.02
CK.54.B6.02
107
115
55
63
15.28
8257
September 2002
-15
777
-10
1011
-5
1293
watt
0
1629
5
2023
7.2
2217
10
2483
Capacity (ASHRAE)
Comp.\C
SC15DL
-15
833
-10
1084
15
3014
a3
a2
watt
-5
1387
0
1748
5
2173
7.2
2381
10
2668
15
3241
c
8227
Power consumption
Comp.\C
SC15DL
-15
534
-10
590
watt
-5
640
0
686
5
726
7.2
742
10
761
15
790
-5
3.30
0
3.50
5
3.67
7.2
3.74
10
3.82
15
3.94
Current consumption
Comp.\C
SC15DL
-15
2.84
-10
3.08
-15
1.45
-10
1.71
-5
2.02
W/W
0
2.37
5
2.79
7.2
2.99
10
3.26
COP (ASHRAE)
Comp.\C
SC15DL
-15
1.56
15
3.82
b
e
Start winding
5
a2
Main winding
Winding
protector
1
2
N
L
2
N
L
Bleeder resistance
a3
W/W
-10
1.84
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-5
2.17
0
2.55
5
2.99
EN 12900/CECOMAF
45C
32C
no subcooling
7.2
3.21
10
3.51
15
4.10
Thermostat
Fan
ASHRAE
45C
32C
32C
Accessories
Devices
Fig.
SC15DL
a3
Starting device
Cover
Starting relay
a2
Starting capacitor 80 F
Run capacitor
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
September 2002
Components
of
starting device
103N1004
118-1917
118-1918
118-1919
CF.54.X2.02
CK.54.B6.02
September 2002
99
SC10/10DL
MBP/HBP Twin Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.Y1.02)
General
SC10/10DL
Code number
104L4091
Application
Application
MBP/HBP
-15 to 15
V/Hz
SC10/10DL
Application
104L
R404A
R407C R507
Lilac stripe
Approvals
4091
Barcode on
white background
8307
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Design
Displacement
cm3
Oil quantity
cm3
1220
2200
cm3
2820
kg
26.8
100
127
2 x 10.29
Motor
Motor size
watt
127
2 x 385
14.8
14.8
5.0/13.7
Approvals
16
175
302
EN 60335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
249
244
B1
183
B2
100
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
September 2002
100
CF.54.Y2.02
CK.54.B6.02
September 2002
-15
961
-10
1272
-5
1642
watt
0
2077
5
2586
7.2
2835
10
3176
15
3855
Starting relay
Starting capacitor
Comp.\C
-15
SC10/10DL 1030
-10
1364
watt
-5
1761
0
2229
5
2776
7.2
3045
10
3412
-5
874
0
951
5
1020
7.2
1047
10
1081
Power consumption
10 11
12
Main winding
15
4146
14
1
2
N
L
-15
693
-10
788
1
2
N
L
watt
Current consumption
-15
5.00
-10
5.32
0
5.90
5
6.16
7.2
6.27
10
6.40
0
2.18
5
2.54
7.2
2.71
10
2.94
-15
1.39
-10
1.61
-5
1.88
13
14
1
2
N
L
Fan
A
-5
5.62
12
Blue
Black
Brown
15
1135
Thermostat
Comp.\C
SC10/10DL
Start winding
Winding
protector
1
2
N
L
2 1
Comp.\C
SC10/10DL
10 11
13
1933
Capacity (ASHRAE)
15
6.63
W/W
15
3.40
service valve
seal ring
COP (ASHRAE)
Comp.\C
SC10/10DL
-15
1.49
W/W
-10
1.73
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-5
2.01
0
2.34
5
2.72
EN 12900/CECOMAF
45C
32C
no subcooling
7.2
2.91
10
3.16
15
3.65
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC10/10DL
Starting relay
117U6005
Starting capacitor 80 F
117U5017
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CF.54.Y2.02
CK.54.B6.02
September 2002
101
SC12/12DL
MBP/HBP Twin Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.Z1.02)
General
SC12/12DL
Code number
104L4092
Application
Application
MBP/HBP
-15 to 15
V/Hz
SC12/12DL
Application
104L
R404A
R407C R507
Lilac stripe
Approvals
4092
Barcode on
white background
8307-3
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSIR
38
32C
F2
38C
F2
S
O
F1
F2
Displacement
cm 3
2 x 12.87
Oil quantity
cm3
1220
2200
cm3
2920
kg
27.8
100
127
Design
Motor
Motor size
watt
127
2 x 495
18.6
18.6
3.7/14.1
Approvals
16
175
302
EN 60 335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
249
244
B1
183
B2
100
B1
B2
1"-14 UNF
location/I.D. mm
12
Solder connector
location/I.D. mm
12
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8260
18
326
September 2002
102
CF.54.Z2.02
CK.54.B6.02
September 2002
-10
1662
-5
2130
watt
0
2680
5
3321
7.2
3634
10
4062
15
4913
Starting relay
Starting capacitor
Comp.\C
-15
SC12/12DL 1354
-10
1781
watt
-5
2285
0
2876
5
3566
7.2
3903
10
4364
-5
1124
0
1212
5
1287
7.2
1316
10
1350
Power consumption
10 11
12
Main winding
15
5284
14
1
2
N
L
-15
912
-10
1025
1
2
N
L
watt
Current consumption
-15
6.23
-10
6.62
0
7.30
5
7.58
7.2
7.69
10
7.82
0
2.21
5
2.58
7.2
2.76
10
3.01
-15
1.39
-10
1.62
-5
1.89
13
14
1
2
N
L
Fan
A
-5
6.98
12
Blue
Black
Brown
15
1400
Thermostat
Comp.\C
SC12/12DL
Start winding
Winding
protector
1
2
N
L
2 1
Comp.\C
SC12/12DL
10 11
13
1933
Capacity (ASHRAE)
15
8.03
W/W
15
3.51
service valve
seal ring
COP (ASHRAE)
Comp.\C
SC12/12DL
-15
1.48
W/W
-10
1.74
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-5
2.03
0
2.37
5
2.77
EN 12900/CECOMAF
45C
32C
no subcooling
7.2
2.97
10
3.23
15
3.77
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC12/12DL
Starting relay
117U6019
Starting capacitor 80 F
117U5017
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7350
(12 mm)
104B0584
(12 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
September 2002
CF.54.Z2.02
CK.54.B6.02
September 2002
103
SC15/15DL
MBP/HBP Twin Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CJ.54.A1.02)
General
SC15/15DL
Code number
104L4093
Application
Application
MBP/HBP
-15 to 15
V/Hz
SC15/15DL
Application
104L
R404A
R407C R507
Lilac stripe
Approvals
4093
Barcode on
white background
8307-2
Compressor
DANFOSS COMPRESSORS
Yellow background
Motor type
CSR
38
32C
F2
38C
F2
S
O
F1
F2
Displacement
cm 3
2 x 15.28
Oil quantity
cm3
1220
2200
cm3
2920
kg
28.0
100
127
Design
Motor
Motor size
watt
127
2 x 550
21.8
21.8
3.5/12.1
Approvals
16
175
302
EN 60 335-2-34
* Operational current for the second compressor time-delayed.
Dimensions
Height
mm
259
254
B1
193
B2
110
B1
B2
1"-14 UNF
location/I.D. mm
16
Solder connector
location/I.D. mm
16
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
6.2 0.09
Compressors on a pallet
pcs.
320
Suction connector
Service valve
8265
18
326
September 2002
104
CJ.54.A2.02
CK.54.B6.02
September 2002
watt
-5
2586
0
3257
5
4047
7.2
4434
10
4966
-5
2774
0
3495
5
4345
7.2
4763
10
5336
Capacity (ASHRAE)
Comp.\C
-15
SC15/15DL 1665
-10
2168
-10
1180
-15
5.68
-10
6.17
-5
1281
0
1372
5
1452
7.2
1484
10
1521
-15
1.45
-10
1.71
1
2
N
L
-5
6.60
0
6.99
5
7.34
7.2
7.47
10
7.63
-5
2.02
0
2.37
5
2.79
7.2
2.99
10
3.26
15
7.88
1
2
N
L
15
1579
15
6482
watt
Current consumption
Comp.\C
SC15/15DL
Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance
watt
Power consumption
Comp.\C
-15
SC15/15DL 1069
15
6027
1
2
N
L
2 1
Thermostat
1932
Comp.\C
-15
SC15/15DL 1554
1
2
N
L
Blue
Black
Brown
Time delay
relay
Safety pressure control
Fan
Thermostat 2
W/W
15
3.82
service valve
seal ring
COP (ASHRAE)
Comp.\C
SC15/15DL
-15
1.56
W/W
-10
1.84
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz
-5
2.17
0
2.55
5
2.99
EN 12900/CECOMAF
45C
32C
no subcooling
7.2
3.21
10
3.51
15
4.10
seal ring
ASHRAE
45C
32C
32C
8214
solder connector
Accessories
Devices
pcs.
SC15/15DL
Cover
103N2009
Cord relief
103N1004
Time-delay relay
Check valve
(to be used with time-delay relay)
1
2
117N0001
020-1014
Service valve
118-7351
(16 mm)
118-7405
(16 mm)
118-3638
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
118-1917
118-1918
Starting device
September 2002
CJ.54.A2.02
CK.54.B6.02
September 2002
105
106
CK.54.B6.02
September 2002
September 2002
CK.54.B6.02
107
Appliance Controls
For the regulation of refrigeration appliances and freezers Danfoss supply a
CFC-free product range of electromechanical thermostats for refrigerators
and electromechanical thermostats for refrigerators and freezers produced
according to customer specification; Hermetic valves for refrigerator/freezer
combinations and for energy saving applications; Service thermostats for all
refrigerating and freezing appliances.
www.danfoss.com/compressors
CK.54.B6.02