COMPRESSORS

Collection of Datasheets

Compressors for R404A/R507 & R407C


220-240V 50Hz & 60Hz, 115V 60Hz

R E F R I G E R AT I O N A N D A I R C O N D I T I O N I N G

R404A/R507, 220-240V 50Hz

R404A/R507, 220-240V 50/60Hz

T-Series
TL4CL
TL4DL

(LBP/MBP)
(MBP/HBP)

Page 10
Page 12

N-Series
NL7CLX

S-Series
SC10CLX
SC10MLX
SC12CLX.2
SC12MLX

(LBP/MBP)

Page 14

F-Series
FR6CL
FR6DL
FR7.5CL
FR8.5CL

(LBP/MBP)
(MBP/HBP)
(LBP/MBP)
(LBP)

Page
Page
Page
Page

16
18
20
22

Page
Page
Page
Page
Page
Page
Page
Page

24
26
28
30
32
34
36
38

Page
Page
Page
Page
Page
Page
Page
Page

40
42
44
46
48
50
52
54

S-Series
SC10CL
(LBP/MBP)
SC10DL
(MBP/HBP)
SC12CL
(LBP/MBP)
SC12DL
(MBP/HBP)
SC15CL
(LBP/MBP)
SC15DL
(MBP/HBP)
SC18CL
(LBP/MBP)
SC21CL
(LBP)
S-Series (Twins)
SC10/10CL (LBP/MBP)
SC10/10DL (MBP/HBP)
SC12/12CL (LBP/MBP)
SC12/12DL (MBP/HBP)
SC15/15CL (LBP/MBP)
SC15/15DL (MBP/HBP)
SC18/18CL (LBP/MBP)
SC21/21CL (LBP)

Page
Page
Page
Page

66
68
70
72

R404A/R507, 115V 60Hz


T-Series
TF4CLX
TFS4.5CLX

(LBP/MBP)
(LBP)

Page 74
Page 76

N-Series
NF5.5CLX
NF7CLX

(LBP/MBP)
(LBP/MBP)

Page 78
Page 80

S-Series
SC10CL
SC12CL
SC12CLX.2
SC12MLX
SC15CLX.2
SC15MLX

(LBP/MBP)
(LBP)
(LBP)
(MBP)
(LBP)
(MBP)

Page
Page
Page
Page
Page
Page

82
84
86
88
90
92

R407C, 220-240V 50Hz


S-Series
SC10DL
(MBP/HBP)
SC12DL
(MBP/HBP)
SC15DL
(MBP/HBP)
S-Series (Twins)
SC10/10DL (MBP/HBP)
SC12/12DL (MBP/HBP)
SC15/15DL (MBP/HBP)

R404A/R507, 220-240V 60Hz


S-Series
SC12CLX
(LBP)
SC15CLX
(LBP)
S-Series (Twins)
SC10/10CLX (LBP/MBP)
SC12/12CLX (LBP)
SC15/15CLX (LBP)

(LBP/MBP)
(MBP)
(LBP)
(MBP)

Page 56
Page 58

Page 94
Page 96
Page 98
Page 100
Page 102
Page 104

Page 60
Page 62
Page 64

CK.54.B6.02

September 2002

1. General

This collection of datasheets contains information on Danfoss hermetic refrigeration compressors for 220-240V and 115V especially designed for refrigeration systems using
refrigerant R404A (CHF2CF3 / CH3CF3 / CH2FCF3) / R507 (CHF2CF3 / CH3CF3) and R407C
(CH2F2 / CHF2CF3 / CH2FCF3).
The programme consists of the basic types TL, TF, NL, NF, FR, SC and SC Twin.

8238-3

8238-5

8238-4

TL (TF similar)

NL (NF similar)

FR

8238-6
8238-7

SC

1.1 Compressor
designations

SC Twin

The compressor designations are built up according to the following system:


Design

Optimization
level

Compressor
size

Application
range

Start
Generation
characteristics

TL, TF
CL
R404/R507 LBP
(MBP)
Blank
Standard
energy level

NL, NF

FR

Nominal
displacement
in cm3

S
Semi-direct intake

DL
R404/R507 HBP
R407C HBP

Blank
universal
(principal rule)

Blank
First
generation

.2
X = HST
Second
characteristics generation
ML
(capillary tube)
R404/R507 MBP
etc.

SC

Examples

TF

September 2002

4.5

CL

NL

CL

FR

DL

SC

15

CL

CK.54.B6.02

.2
3

1.2 Design

All Danfoss compressors for R404A/R507 and R407C from the TL, TF, NL, NF, FR, and SC
range are standard efficiency types.

1.3 Type label

Compressors for 220-240V have a yellow label with the type designation. This label has a
lilac stripe and the text R404A R507 or R404A R407C R507.
Compressors for 115V have a green label with the type designation. This label has a lilac
stripe and the text R404A R507.

SC10DL

104L

R404A
R407CR507

Approvals
Barcode on
white background

115V~60Hz
MBP HST

R404A
R507

Lilac stripe

2525

DANFOSS COMPRESSORS

Yellow background

8306-2

Lilac stripe

104L

SC12MLX
Application

220-240V~50Hz
MBP/HBP HST

Barcode on
white background

1606

DANFOSS COMPRESSORS

8315-10

Application

Green background

The country of origin indicated on the compressor paper label and on the compressor cover
varies depending on the manufacturing place. Information can be found on our technical
information sheet Country of Origin.
1.4 Data stamping

The compressor type and production date are stamped on the side of the compressor. The
information may be as follows,
L-4CL-2071
F-202E2207
The first line states the model designation and the code no.
L= last letter (or last two letters) of the compressor type
4CL
= nominal displacement and application
2071
= 4 last digits in the code no.
(= position mark)
The second line states the date of manufacture and internal Danfoss codes.
F
= manufacturing place (F = Germany, AL = Slovenia, AM = Mexico)
20
= week 20
2
= 2002
E
= Friday (A = Monday etc.)
220
= nominal voltage
7
= internal Danfoss code

1.5 Compressor
dimensions

The build-in conditions (total height, weight, tube dimensions etc.) are specified in the
individual datasheets including dimensioned sketches for the compressors.

2. Application range CL

Compressors with denominations ending with CL are primarily designed for low evaporating
temperatures (LBP Low Back Pressure) for use in commercial refrigerators, freezers and
similar applications in regions with normal supply voltage.

ML

Compressors with denominations ending with ML are primarily designed for medium evaporation temperatures (MBP Medium Back Pressure) for use in commercial refrigerators,
bottle coolers, ice machines and similar applications.

DL

Compressors with denominations ending with DL are primarily designed for high evaporation temperatures (HBP High Back Pressure) for use in commercial refrigerators, liquid
coolers, dehumidifiers, refrigerated display counters, vending machines, heat pumps, and
similar applications.
The following table shows the normally recommended applications as regards voltage/
frequency, ambient temperature, evaporating temperature and necessary compressor cooling.
The recommendations must be regarded as a guideline only as they presuppose a proper
dimensioning of the refrigeration system.

CK.54.B6.02

September 2002

Compressor

Mains [V/Hz]

32C

Ambient temperature
38C

43C

LBP MBP HBP LBP MBP HBP LBP MBP HBP

TL4CL
TL4DL
NL7CLX
FR6 - 7.5CL
FR8.5CL
FR6DL
R404A/R507, SC10 - 12 - 15 - 18CL
220-240V 50Hz
SC21CL
SC10 - 12 - 15DL
SC10/10 - 12/12CL

198 - 254 /50


198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50

SC15/15CL - 18/18CL
SC21/21CL
SC10/10 - 12/12 - 15/15DL
SC12 - 15CLX
R404A/R507,
SC10/10CLX
220-240V 60Hz
SC12/12 - 15/15CLX

198 - 254 /50


198 - 254 /50
198 - 254 /50
198 - 254 /60
198 - 254 /60
198 - 254 /60
198 - 254 /50
198 - 254 /60
198 - 254 /50
198 - 254 /60
187 - 254 /50
187 - 254 /60
95 - 135 /60
103 - 135 /60
95 - 135 /60
103 - 135 /60
95 - 135 /60
108 - 135 /60
103 - 127 /60
103 - 127 /60
103 - 127 /60
95 - 135 /60
95 - 135 /60
103 - 135 /60
198 - 254 /50
198 - 254 /50

SC10CLX
R404A/R507,
SC12CLX.2
220-240V 50/60Hz
SC10 - 12MLX
TF4CLX
TFS4.5CLX
NF5.5CLX

R404A/R507,
115V 60Hz

NF7CLX
SC10CL
SC12CL
SC15CLX.2
SC12MLX
SC15MLX

SC10 - 12 - 15DL
R407C,
220-240V 50Hz SC10/10 - 12/12 - 15/15DL

S
O
F1
F2
*
**

=
=
=
=
=
=
=

F2
F2
F2
F2
F2
F2
F2
F2
F2

F2
F2
F2
F2

F1
F1
F2
F2
F2
F2
F2
F2
F2

F2
F2
F2

F2
F2

F2

F2
F2

F2

F2
F2
F2

F2
F2

F2
F2
F2
F2
F2
F2
F2

F2
F2

F2
F2
F2

F2

F2
F2
F1

F1
F1
F2
F2
F2
F2
F2
F2
F2

F2
F2
F2

F2
F2
F2
F2
F2

F2
F2

F2

F2
F2

F2

F2
F2

F2

F2
F2

F2
F2
F2
F2
F2
F2
F2

F2

F2
F2
F2
F2

F2

F2

F2

F2

F2

F2
F2
F1

F1
F1
F2
F2
F2
F2
F2
F2
F2

F2
F2
F2

F2
F2
F2
F2
F2

F2
F2
F1

F2
F2
F2

F2
F2
F2
F2
F2

Static cooling normally sufficient


Oil cooling
Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temp.)
Fan cooling 3.0 m/s necessary
Outside application range, not recommended
Run capacitor compulsory
Not applicable below -25C evaporating temperature in 43C ambient temperature
above 240V

The application limits regarding evaporating temperatures and motor systems are specified in the individual
compressor datasheets.

2.1 Design limits

Condensing temperature
Winding temperature

September 2002

In order to secure a satisfying lifetime of the compressor, and to protect the compressor
against overload, some design criteria for the appliances must be fulfilled.
Both the condensing temperature and the compressor temperature should be kept as low
as possible. This can be done by using well-dimensioned condenser surfaces and by ensuring
good ventilation around the compressor under all operating conditions.
In order to protect the compressor against overload, the compressor has to start and work
properly through pressure peaks obtained in the highest ambient temperature and lowest
working voltage. At peak load the condensing temperature must not exceed 60C. The
winding temperature must not exceed 135C.
At stable operation conditions the condensing temperature must not exceed 50C. The
winding temperature must not exceed 125C.
These limitations ensure a protection of valves, gaskets, oil, and motor insulation.

CK.54.B6.02

3. Electrical equipment

The compressors are equipped with a single-phase AC motor. All compressors for R404A/
R507 and R407C are designed only for use with High Starting Torque (HST).
The electrical equipments are classified as normal tight (IP20).
The motor protector is built into the motor (winding protector). Exception are compressors
with the denominations TF and NF and some SCs.
Earth connections are located on the bracket around the current lead-in of the compressor.
No attempt must be made to start the compressor without a complete starting device.
The compressors can be supplied with the following motor systems:

8076

8077-2

3.1 HST (CSIR)

TL, NL, FR

TF, NF

8088

8467

Compressors with the motor type Capacitor Start Induction Run (CSIR) have a starting
device for High Starting Torque (HST). This starting device consists of a starting relay and
a starting capacitor and is used for compressors with the denominations TL, TF, NL, NF, FR
and SC. The following designs of starting devices exist:
a) Relay + starting capacitor + cord relief + cover, used for compressors with the denominations TL, NL, FR and SC.
b) Relay housing including motor protector + starting capacitor + cord relief (2x) + cover,
used for compressors with the denomination TF and NF.
c) Relay + starting capacitor (with bracket) + cover/protector/protector holder (parts of
compressor), used for compressors with the denomination SC which have an external
protector.
The starting device requires no pressure-equalization before each start and is normally
used in refrigerating systems with expansion valve as throttling device or in capillary tube
systems where pressure equalizing is not obtained during the standstill periods.
The starting capacitor is designed for short time cut-in. 1.7% ED, which is stamped on
the starting capacitor, means for instance max. 10 cutins per hour each with a duration of
6 seconds (normally shorter than 1 sec.).

SC

SC (external protector)

CK.54.B6.02

September 2002

8191

8467-2

3.5 HST (CSR)

SC

SC (external protector)

Compressors with the motor type Capacitor Start Run (CSR) have a starting device for
High Starting Torque (HST). The following designs of starting devices exist:
a) Relay + starting capacitor + run capacitor + terminal board + cord relief + cover, used for
compressors with the denomination SC.
b) Relay + starting capacitor (with bracket) run capacitor + cover/protector/protector holder
(parts of compressor), used for compressors with the denomination SC which have an
external protector.
The starting device is mandatory for some of the biggest SC compressors. The starting capacitor is designed for short time cut-in. 1.7% ED, which is stamped on the starting capacitor, means for instance max. 10 cut-ins per hour each with a duration of 6 seconds.
For further information on which starting device to use on individual compressors, please
refer to the actual datasheets (some compressors have limitations for either LST or HST).

3.6 Connections

The electrical equipments are equipped with connectors depending on the ordered code
number,
Starting relays: 6.3 mm spade connectors only
The power supply must be connected as shown in the wiring diagrams for the chosen
electrical equipment given in the actual datasheets.

3.7 Approvals
R

THERMALLY
PROTECTED

Approval mark

September 2002

8459-4

SC12MLX
115V-60Hz
1PH

The compressors have been approved in respect of safety by testing


authorities in the majority of Western European countries. Actual
standards to which the compressors have been approved are
specified in the individual datasheets. Approval markings appear
on the compressor labels.
Most compressors which are capable of running at 60Hz have been
approved in respect of safety by testing authorities UL and CSA.
Actual standards to which the compressors have been approved
are specified in the individual datasheets. Approval markings appear
on a separate approval mark label.

CK.54.B6.02

4. Moisture and
Impurities

The compressors are dried to a maximum moisture content of 60 to 75 mg depending on


the compressor size. The maximum impurity content is 40 to 50 mg depending on the
compressor size.

5. Max. refrigerant
charge

The refrigerant charge must never be too large to be contained on the condenser side of the
refrigeration system. Only the refrigerant amount which is necessary for the system to
function must be charged.
The refrigerant amount may be critical as regards oil foaming and liquid hammer after long
standstill periods. Because of this, limitations of refrigerant charges have been introduced.
The maximum refrigerant charge is specified in the individual datasheets.
If these limitations cannot be complied with, the risk may be reduced if a crankcase heater
is properly used or if a pump down system is established.

6. Oil charge

The compressors are supplied charged with dried and degassed oil, which is normally
sufficient for the lifetime of the compressor. The refrigeration systems and the system
components must be dimensioned in such a way that the oil can be lead back continuously
to the compressor housing without accumulating in the system, e.g. without oil pockets
and with sufficient gas velocity. The compressors use polyolester oils and are approved
only for these oils and R404A/R507 respectively R407C.
The oil charge is specified in the individual datasheets.

7. Mounting

Soldering problems caused by oil in the connectors can be avoided by placing the compressor on its baseplate some time before soldering it into the system. The compressor
must never be placed upside down when mounting the rubber grommets in the baseplate.
Instead place the compressor on its side with the connectors upwards.

7.1 Mounting
accessories

Washer

Nut M6

Washer

Grommet sleeve

Steel pin

Compressor base

Clip

Compressor base

3327-2

7382-2

Cabinet base
Cabinet base

Screw M6 x 25

Rubber grommet

Rubber grommet

Bolt joint

Snap-on joint

The mounting accessories for the compressors are available in two versions, with bolt joint
or snap-on joint. The code numbers for the mounting accessories are specified in the individual compressor datasheets.
These rubber grommets are designed for the 16 mm holes of the baseplate:
Bolt joint for one compressor in a bag
118-1917 or 118-1946
Bolt joint in quantities
118-1918 or 118-1945
Snap-on in quantities
118-1919 or 118-1944
Snap-on for one compressor in a bag
118-1947
These rubber grommets are designed for the 19 mm holes of the baseplate:
Bolt joint in quantities
118-1948

CK.54.B6.02

September 2002

8. Condition at delivery

The compressors are delivered without mounted starting devices on pallets with the dimensions 1144 x 800 mm. Quantities per pallets are specified in the individual datasheets.
Electrical equipment is packed in separate boxes.
The most important performance controls carried out during manufacturing are,
A high potential insulation test with 1650V for 1 second
Pumping capacity
Tightness of discharge side and discharge valve
Tightness of compressor housing
Check of the right oil charge
Noise test
The compressors are supplied with sealed connectors and the sealing should not be removed before the system assembly takes place (max. 15 minutes with open connectors).

9. Twin compressors

The Twin version consists of two SC compressors mounted on a common baseplate. The
two compressors are joined by an oil-equalizing tube and also have an intake manifold with
screw connector for a service valve or a solder connector (these parts are supplied as
accessories).
Each Twin compressor has to be ordered with two sets of electrical equipment and mounting
accessories. To ensure optimum starting characteristics and the smallest possible mains
load we recommend that the compressors be equipped with a time-delay relay for start of
the second compressor.
Twin compressors can operate with capacity regulation depending on the controls used.

10. Conversion from


R502/R22 to
R404/R507
or R407C

Normally, the same system components can be used as were used with R502. However, an
adjustment of the charge has to be made.
A drier with 3 desiccant of Molecular Sieves or a hard core drier compatible with R404A
must always be used.
Rules for dryness and cleanliness of system components (DIN 8964) are transferred to
R404A systems.
The system components must not contain mineral oil or greasy substances.
The compressors must be soldered into the system no later than 15 minutes after the
connector seals have been removed.
The same evacuation procedure as for R502/R22 systems must be used.
Max. 1% non-condensable gases.
The system must not contain any chlorine.
The charging equipment must only be used for R404A/R507 respectively R407C.

11. Warnings

September 2002

No high potential test nor start tests must be carried out while the compressor is under
vacuum.
No attempt must be made to start the compressor without a complete starting device.
Allow the compressor to assume a temperature above 10C before starting the first time in
order to avoid starting problems.
Anti-freeze agents must not be used in the compressors as such agents are damaging to
several of the materials used. In particular, the ethyl or methyl alcohol contents of such
anti-freeze agents have a destructive effect on the synthetic motor insulation.
CK.54.B6.02

TL4CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.52.A1.02)
General
TL4CL

Code number

102U2071

102U

TL4CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/MBP

Barcode on
white background

-45 to -5

Yellow background

2071

8294

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

280

600

cm3

1690

kg

7.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

3.86

16

Motor size

watt

140

LRA (rated after 4 sec. UL984) HST

5.7

Cut-in current HST

5.7

Resistance, main and start winding (25C)

14.8/14.5

Dimensions
Height

mm

173

169

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

170
178
186
204

C or
D

pcs.

105

105
107

A B

Compressors on a pallet

D
C

or

222
176

31.5
28

Suction connector

EN 60335-2-34

30

Approvals

35
70
100

Motor

125

102

September 2002

10

CF.52.A2.02

CK.54.B6.02

71

29

51 20

45

157
60.5
66

8263

96
117

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
TL4CL

-45
52

-40
65

-35
84

-30
110

watt
-25
142

-23.3
155

-20
182

-15
230

-10
286

-5
352
c

Capacity (ASHRAE)
Comp.\C
TL4CL

-45
60

-40
76

watt
-35
98

-30
128

-25
166

-23.3
180

-20
212

-15
268

-10
334

-5
411
b

Power consumption
Comp.\C
TL4CL

-45
81

-40
91

8219

watt
-35
105

-30
121

-25
140

-23.3
147

-20
160

-15
179

-10
198

-5
215

a2
d

Current consumption
Comp.\C
TL4CL

-45
0.89

-40
0.79

A
-35
0.80

-30
0.88

-25
1.01

-23.3
1.05

-20
1.14

-15
1.25

-10
1.28

-5
1.31

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TL4CL

-45
0.64

W/W

-40
0.72

-35
0.81

-30
0.90

-25
1.02

-23.3
1.06

-20
1.14

-15
1.28

-10
1.45

-40
0.83

-35
0.94

-30
1.05

-25
1.18

-23.3
1.23

-20
1.33

-15
1.50

-10
1.69

COP (ASHRAE)
Comp.\C
TL4CL

-45
0.74

-5
1.64

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

-5
1.92

Main winding

Winding protector Start winding

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

TL4CL

Starting relay

a2

117U6000

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.52.A2.02

CK.54.B6.02

September 2002

11

TL4DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.52.B1.02)
General
TL4DL

Code number

102U2038

102U

TL4DL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP/HBP

Barcode on
white background

-20 to 10

Yellow background

2038

8298

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

280

600

cm3

1690

kg

7.5

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

3.86

16

Motor size

watt

175

LRA (rated after 4 sec. UL984) HST

7.5

Cut-in current HST

7.5

Resistance, main and start winding (25C)

12.0/20.0

Dimensions
Height

mm

173

169

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

170
178
186
204

C or
D

pcs.

105

105
107

A B

Compressors on a pallet

D
C

or

222
176

31.5
28

Suction connector

EN 60335-2-34

30

Approvals

35
70
100

Motor

125

102

September 2002

12

CF.52.B2.02

CK.54.B6.02

71

29

51 20

45

157
60.5
66

8263

96
117

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
TL4DL

-20
196

-15
229

-10
281

watt

-5
349

0
432

5
527

7.2
572

10
631
c

Capacity (ASHRAE)
Comp.\C
TL4DL

-20
229

-15
267

watt
-10
328

-5
409

0
506

5
619

7.2
672

10
742
b

Power consumption
Comp.\C
TL4DL

-20
169

-15
186

watt
-10
203

-5
221

0
239

5
256

7.2
263

8219

10
272

a2
d

Current consumption
Comp.\C
TL4DL

-20
1.22

-15
1.28

A
-10
1.34

-5
1.41

0
1.47

5
1.54

7.2
1.56

10
1.60

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TL4DL

-20
1.16

W/W

-15
1.23

-10
1.38

-5
1.58

0
1.81

5
2.06

7.2
2.17

-15
1.44

-10
1.61

-5
1.85

0
2.12

5
2.42

7.2
2.55

COP (ASHRAE)
Comp.\C
TL4DL

-20
1.36

10
2.32

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

10
2.73

Main winding

Winding protector Start winding

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

TL4DL

Starting relay

a2

117U6001

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.52.B2.02

CK.54.B6.02

September 2002

13

NL7CLX
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet
General
NL7CLX

Code number

105F3710

105F

NL7CLX
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/MBP

Barcode on
white background

-45 to -5

Yellow background

3710

DANFOSS COMPRESSORS

8466

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

43

32C

F1

38C

F1

43C

F2

Displacement

cm3

7.27

Oil quantity

cm3

320

400

2310

kg

10.4

Comp. cooling at ambient temp.

S
O
F1

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

F2

Design

Maximum refrigerant charge


Free gas vol. in compressor

cm

Weight without electrical equipment

204
170

Motor size

watt

235

LRA (rated after 4 sec. UL984) HST

10.4

Cut-in current HST

100
70

Motor

10.4

Resistance, main and start winding (25C)

16
178

8.2/14.7

Approvals

EN 60335-2-34

205

E
C

8.2 0.09

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

254

80

8248

51

72

166

Compressors on a pallet

102.5

location/I.D. mm

113

September 2002

14

CF.53.I1.02

CK.54.B6.02

75.5

location/I.D. mm

Process connector

27

47

54
78

Suction connector

A B
93.5

203
197

15

A
B

60.5

mm

35

Height

25

Dimensions

119
127

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
NL7CLX

-45

-40

-35

watt

-30

-25
328

-23.3
360

-20

-15

-10

-5
c

Capacity (ASHRAE)
Comp.\C
NL7CLX

-45

-40

watt
-35

-30

-25
380

-23.3
419

-20

-15

-10

-5
b

Power consumption
Comp.\C
NL7CLX

-45

-40

watt
-35

-30

-25
276

-23.3
289

-20

-15

-10

8219

-5

a2
d

Current consumption
Comp.\C
NL7CLX

-45

-40

A
-35

-30

-25
1.64

-23.3
1.68

-20

-15

-10

-5
c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL7CLX

-45

-40

-35

W/W
-30

-25
1.18

-23.3
1.24

-20

-25
1.37

-23.3
1.44

-20

-15

-10

-45

12

13
14

COP (ASHRAE)
Comp.\C
NL7CLX

-5

W/W
-40

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz,
preliminary data

-35

-30

EN 12900/CECOMAF
45C
32C
45C

-15

-10

-5

Main winding

Winding protector Start winding

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

NL7CLX

Starting relay

a2

117U6002
103N2010

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.53.I1.02

CK.54.B6.02

September 2002

15

FR6CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.53.A1.02)
General
FR6CL

Code number

103U2670

103U

FR6CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/MBP

Barcode on
white background

-45 to -5

Yellow background

2670

8295

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

450

850

cm3

1350

kg

10.5

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.23

204
178

16

19

215

8.2

Cut-in current HST

8.2

Resistance, main and start winding (25C)

8.9/12.0

Approvals

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

A B
102
130

191

location/I.D. mm

30

B
Suction connector

C
E

196

25

30

mm

Compressors on a pallet

127
165
170
186
200

127

Height

9.7

EN 60335-2-34

Dimensions

35
127
150

watt

LRA (rated after 4 sec. UL984) HST

80

122.5

September 2002

16

CF.53.A2.02

CK.54.B6.02

8253

24

40

40

55

156

243

32
55

Motor size

101.6
70
60.5

Motor

124.5
127.5

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
FR6CL

-45
77

-40
108

-35
145

-30
189

watt
-25
243

-23.3
263

-20
307

-15
383

-10
473

-5
578
c

Capacity (ASHRAE)
Comp.\C
FR6CL

-45
90

-40
125

watt
-35
168

-30
220

-25
283

-23.3
307

-20
358

-15
447

-10
553

-5
676
b

Power consumption
Comp.\C
FR6CL

-45
126

-40
152

watt
-35
180

-30
210

-25
242

-23.3
253

-20
276

-15
313

-10
353

8219

-5
395

a2
d

Current consumption
Comp.\C
FR6CL

-45
1.13

-40
1.18

A
-35
1.26

-30
1.35

-25
1.46

-23.3
1.51

-20
1.60

-15
1.75

-10
1.91

-5
2.09

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
FR6CL

-45
0.61

W/W

-40
0.71

-35
0.80

-30
0.90

-25
1.00

-23.3
1.04

-20
1.11

-15
1.22

-10
1.34

-40
0.82

-35
0.94

-30
1.05

-25
1.17

-23.3
1.21

-20
1.29

-15
1.43

-10
1.57

COP (ASHRAE)
Comp.\C
FR6CL

-45
0.71

-5
1.47

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

-5
1.71

Main winding

Winding protector Start winding

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

FR6CL

Starting relay

a2

117U6015
103N2010

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.53.A2.02

CK.54.B6.02

September 2002

17

FR6DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.53.C1.02)
General
FR6DL

Code number

103U2680

103U

FR6DL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP/HBP

Barcode on
white background

-20 to 15

Yellow background

2680

8299

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

450

850

cm3

1350

kg

10.5

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.23

204
178

16

19

watt

275

10.0

Cut-in current HST

10.0

Resistance, main and start winding (25C)

7.3/12.0

Approvals

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

A B
102
130

191

location/I.D. mm

30

B
Suction connector

C
E

196

25

30

mm

Compressors on a pallet

127
165
170
186
200

127

Height

9.7

EN 60335-2-34

Dimensions

35
127
150

LRA (rated after 4 sec. UL984) HST

80

122.5

September 2002

18

CF.53.C2.02

CK.54.B6.02

8253

24

40

40

55

156

243

32
55

Motor size

101.6
70
60.5

Motor

124.5
127.5

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
FR6DL

-20
317

-15
385

-10
471

watt

-5
576

0
698

5
840

7.2
907

10
999

15
1177
c

Capacity (ASHRAE)
Comp.\C
FR6DL

-20
370

-15
449

watt
-10
550

-5
673

0
818

5
986

7.2
1065

10
1176

15
1389
b

Power consumption
Comp.\C
FR6DL

-20
290

-15
321

watt
-10
354

-5
388

0
423

5
456

7.2
469

10
485

8219

15
509

a2
d

Current consumption
Comp.\C
FR6DL

-20
1.91

-15
1.99

A
-10
2.10

-5
2.23

0
2.37

5
2.51

7.2
2.56

10
2.62

15
2.70

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
FR6DL

-20
1.09

W/W

-15
1.20

-10
1.33

-5
1.48

0
1.65

5
1.84

7.2
1.93

10
2.06

-15
1.40

-10
1.56

-5
1.73

0
1.94

5
2.16

7.2
2.27

10
2.42

COP (ASHRAE)
Comp.\C
FR6DL

-20
1.27

15
2.31

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

15
2.73

Main winding

Winding protector Start winding

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

FR6DL

Starting relay

a2

117U6010
103N2010

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.53.C2.02

CK.54.B6.02

September 2002

19

FR7.5CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.53.D1.02)
General
FR7.5CL

Code number

103U2790

103U

FR7.5CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/MBP

Barcode on
white background

-45 to -5

Yellow background

2790

8295-3

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

450

850

cm3

1350

kg

10.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.93

204
178

16

19

235

9.1

Cut-in current HST

9.1

Resistance, main and start winding (25C)

8.8/12.0

Approvals

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

A B
102
130

191

location/I.D. mm

30

B
Suction connector

C
E

196

25

30

mm

Compressors on a pallet

127
165
170
186
200

127

Height

9.7

EN 60335-2-34

Dimensions

35
127
150

watt

LRA (rated after 4 sec. UL984) HST

80

122.5

September 2002

20

CF.53.D2.02

CK.54.B6.02

8253

24

40

40

55

156

243

32
55

Motor size

101.6
70
60.5

Motor

124.5
127.5

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
FR7.5CL

-45
86

-40
114

-35
154

watt

-30
202

-25
262

-23.3
285

-20
333

-15
418

-10
515

-5
630
c

Capacity (ASHRAE)
Comp.\C
FR7.5CL

-45
101

-40
132

watt
-35
178

-30
235

-25
305

-23.3
333

-20
388

-15
488

-10
602

-5
737
b

Power consumption
Comp.\C
FR7.5CL

-45
142

-40
168

watt
-35
197

-30
231

-25
267

-23.3
280

-20
307

-15
349

-10
395

8219

-5
440

a2
d

Current consumption
Comp.\C
FR7.5CL

-45
1.39

-40
1.44

A
-35
1.52

-30
1.62

-25
1.75

-23.3
1.81

-20
1.91

-15
2.09

-10
2.28

-5
2.51

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
FR7.5CL

-45
0.61

W/W

-40
0.68

-35
0.78

-30
0.88

-25
0.98

-23.3
1.02

-20
1.09

-15
1.20

-10
1.30

-40
0.79

-35
0.90

-30
1.02

-25
1.14

-23.3
1.19

-20
1.27

-15
1.40

-10
1.53

COP (ASHRAE)
Comp.\C
FR7.5CL

-45
0.71

-5
1.43

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz,
preliminary data

EN 12900/CECOMAF
45C
32C
45C

-5
1.67

Main winding

Winding protector Start winding

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

FR7.5CL

Starting relay

a2

117U6016
103N2010

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.53.D2.02

CK.54.B6.02

September 2002

21

FR8.5CL
LBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.53.B1.02)
General
FR8.5CL

Code number

103U2890

103U

FR8.5CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-45 to -10

Yellow background

2890

8295-2

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

450

850

cm3

1350

kg

10.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

7.95

204
178

16

19

watt

275

10.0

Cut-in current HST

10.0

Resistance, main and start winding (25C)

7.3/12.0

Approvals

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

A B
102
130

191

location/I.D. mm

30

B
Suction connector

C
E

196

25

30

mm

Compressors on a pallet

127
165
170
186
200

127

Height

9.7

EN 60335-2-34

Dimensions

35
127
150

LRA (rated after 4 sec. UL984) HST

80

122.5

September 2002

22

CF.53.B2.02

CK.54.B6.02

8253

24

40

40

55

156

243

32
55

Motor size

101.6
70
60.5

Motor

124.5
127.5

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
FR8.5CL

-45
99

-40
126

-35
168

watt

-30
222

-25
290

-23.3
317

-20
372

-15
468

-10
577
c

Capacity (ASHRAE)
Comp.\C
FR8.5CL

-45
115

-40
147

watt
-35
195

-30
259

-25
338

-23.3
369

-20
434

-15
546

-10
674
b

Power consumption
Comp.\C
FR8.5CL

-45
171

-40
198

watt
-35
231

-30
271

-25
315

-23.3
331

-20
364

-15
417

8219

-10
472

a2
d

Current consumption
Comp.\C
FR8.5CL

-45
1.61

-40
1.64

A
-35
1.72

-30
1.83

-25
1.97

-23.3
2.03

-20
2.15

-15
2.35

-10
2.57

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
FR8.5CL

-45
0.58

W/W

-40
0.64

-35
0.72

-30
0.82

-25
0.92

-23.3
0.96

-20
1.02

-15
1.12

-40
0.74

-35
0.84

-30
0.96

-25
1.07

-23.3
1.11

-20
1.19

-15
1.31

COP (ASHRAE)
Comp.\C
FR8.5CL

-45
0.67

-10
1.22

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

-10
1.43

Main winding

Winding protector Start winding

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

FR8.5CL

Starting relay

a2

117U6010
103N2010

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.53.B2.02

CK.54.B6.02

September 2002

23

SC10CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.A1.02)
General
SC10CL

Code number

104L2523

104L

SC10CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/MBP

Barcode on
white background

-35 to -5

Yellow background

2523

DANFOSS COMPRESSORS

8296

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

550

1300

cm3

1460

kg

13.1

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

315

12.6

Cut-in current HST

12.6

Resistance, main and start winding (25C)

6.7/11.8

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

209

203

B1

183

B2

100

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

August 2002

24

CF.54.A2.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

10.29

8258

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10CL

-35
168

-30
258

-25
365

watt
-23.3
405

-20
489

-15
634

-10
800

-5
991
c

Capacity (ASHRAE)
Comp.\C
SC10CL

-35
195

-30
300

watt
-25
424

-23.3
470

-20
569

-15
737

-10
932

-5
1154
b
8222

Power consumption
Comp.\C
SC10CL

-35
243

-30
294

watt
-25
350

-23.3
370

-20
410

-15
471

-10
530

-5
584

a2
d

Current consumption
Comp.\C
SC10CL

-35
1.91

-30
2.05

A
-25
2.22

-23.3
2.27

-20
2.39

-15
2.59

-10
2.81

-5
3.04

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC10CL

-35
0.69

W/W

-30
0.88

-25
1.04

-23.3
1.09

-20
1.19

-15
1.35

-10
1.51

-30
1.02

-25
1.21

-23.3
1.27

-20
1.39

-15
1.57

-10
1.76

COP (ASHRAE)
Comp.\C
SC10CL

-35
0.80

-5
1.70

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

-5
1.98

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC10CL

Starting relay

a2

117U6003

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.A2.02

CK.54.B6.02

August 2002

25

SC10DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.K2.02)
General
SC10DL

Code number

104L2525

104L

SC10DL
Application

R404A
R407C R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP/HBP

Barcode on
white background

-20 to 15

Yellow background

2525

DANFOSS COMPRESSORS

8306

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

600

1300

cm3

1410

kg

13.1

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

385

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

209

203

B1

183

B2

100

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

August 2002

26

CF.54.K3.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

10.29

8258

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10DL

-20
471

-15
611

-10
775

watt
-5
968

0
1192

5
1450

7.2
1576

10
1747

15
2085
c

Capacity (ASHRAE)
Comp.\C
SC10DL

-20
547

-15
710

watt
-10
902

-5
1128

0
1391

5
1696

7.2
1845

10
2048

15
2451
b
8222

Power consumption
Comp.\C
SC10DL

-20
373

-15
429

watt
-10
479

-5
522

0
559

5
590

7.2
601

10
614

15
631

a2
d

Current consumption
Comp.\C
SC10DL

-20
2.55

-15
2.78

A
-10
2.97

-5
3.15

0
3.30

5
3.42

7.2
3.47

10
3.53

15
3.61

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC10DL

-20
1.26

W/W

-15
1.42

-10
1.62

-5
1.85

0
2.13

5
2.46

7.2
2.62

10
2.85

-15
1.66

-10
1.89

-5
2.16

0
2.49

5
2.88

7.2
3.07

10
3.34

COP (ASHRAE)
Comp.\C
SC10DL

-20
1.47

15
3.30

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

15
3.88

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC10DL

Starting relay

a2

117U6005

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.K3.02

CK.54.B6.02

August 2002

27

SC12CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.B1.02)
General
SC12CL

Code number

104L2623

104L

SC12CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/MBP

Barcode on
white background

-45 to -5

Yellow background

2623

DANFOSS COMPRESSORS

8296-4

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

550

1300

cm3

1460

kg

12.5

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

385

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

209

203

B1

183

B2

100

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

August 2002

28

CF.54.B2.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

12.87

8258

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC12CL

-45
58

-40
140

-35
237

watt
-30
353

-25
490

-23.3
541

-20
650

-15
835

-10
1048

-5
1292
c

Capacity (ASHRAE)
Comp.\C
SC12CL

-45
67

-40
162

watt
-35
275

-30
410

-25
568

-23.3
629

-20
754

-15
971

-10
1220

-5
1505

b
8222

Power consumption
Comp.\C
SC12CL

-45
190

-40
253

watt
-35
316

-30
380

-25
445

-23.3
468

-20
512

-15
581

-10
654

-5
730

-35
2.43

-30
2.61

-25
2.82

-23.3
2.90

-20
3.06

-15
3.34

-10
3.64

-5
3.97

-30
0.93

-25
1.10

-23.3
1.16

-20
1.27

-15
1.44

-10
1.60

Current consumption
Comp.\C
SC12CL

-45
2.15

-40
2.27

-45
0.30

-40
0.55

-35
0.75

-45
0.35

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-35
0.87

-30
1.08

-25
1.28

EN 12900/CECOMAF
45C
32C
45C

-23.3
1.34

-20
1.47

-15
1.67

-10
1.87

12

-5
2.06

13
14

-5
1.77

W/W
-40
0.64

c
11

10

W/W

COP (ASHRAE)
Comp.\C
SC12CL

COP (EN 12900/CECOMAF)


Comp.\C
SC12CL

a2

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC12CL

Starting relay

a2

117U6005

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.B2.02

CK.54.B6.02

August 2002

29

SC12DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.L2.02)
General
SC12DL

Code number

104L2625

104L

SC12DL
Application

R404A
R407C R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP/HBP

Barcode on
white background

-20 to 15

Yellow background

2625

DANFOSS COMPRESSORS

8306-3

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

600

1300

cm3

1460

kg

13.6

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

495

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

219

213

B1

193

B2

110

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

August 2002

30

CF.54.L3.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

12.87

8258

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC12DL

-20
609

-15
806

-10
1028

watt
-5
1279

0
1565

5
1890

7.2
2046

10
2258

15
2674
c

Capacity (ASHRAE)
Comp.\C
SC12DL

-20
707

-15
937

watt
-10
1196

-5
1491

0
1827

5
2210

7.2
2396

10
2647

15
3144
b
8222

Power consumption
Comp.\C
SC12DL

-20
489

-15
563

watt
-10
624

-5
675

0
717

5
750

7.2
763

10
778

15
800

a2
d

Current consumption
Comp.\C
SC12DL

-20
3.37

-15
3.65

A
-10
3.89

-5
4.11

0
4.29

5
4.44

7.2
4.50

10
4.56

15
4.66

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC12DL

-20
1.24

W/W

-15
1.43

-10
1.65

-5
1.90

0
2.18

5
2.52

7.2
2.68

10
2.90

-15
1.67

-10
1.92

-5
2.21

0
2.55

5
2.95

7.2
3.14

10
3.40

COP (ASHRAE)
Comp.\C
SC12DL

-20
1.45

15
3.34

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

15
3.93

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC12DL

Starting relay

a2

117U6019

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.L3.02

CK.54.B6.02

August 2002

31

SC15CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.C1.02)
General
SC15CL

Code number

104L2853

104L

SC15CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/MBP

Barcode on
white background

-40 to -5

Yellow background

2853

DANFOSS COMPRESSORS

8296-5

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

550

1300

cm3

1510

kg

13.8

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

495

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

219

213

B1

193

B2

110

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

August 2002

32

CF.54.C2.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

15.28

8258

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15CL

-40
151

-35
299

-30
452

watt
-25
615

-23.3
673

-20
792

-15
988

-10
1208

-5
1458
c

Capacity (ASHRAE)
Comp.\C
SC15CL

-40
175

-35
347

watt
-30
525

-25
714

-23.3
782

-20
920

-15
1149

-10
1407

-5
1699

b
8222

Power consumption
Comp.\C
SC15CL

-40
298

-35
400

watt
-30
485

-25
560

-23.3
584

-20
631

-15
706

-10
790

-5
891

-30
3.28

-25
3.52

-23.3
3.61

-20
3.77

-15
4.04

-10
4.31

-5
4.60

-25
1.10

-23.3
1.15

-20
1.25

-15
1.40

-10
1.53

Current consumption
Comp.\C
SC15CL

-40
2.83

-35
3.05

-40
0.51

-35
0.75

-30
0.93

-40
0.59

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-30
1.08

-25
1.27

-23.3
1.34

EN 12900/CECOMAF
45C
32C
45C

-20
1.46

-15
1.63

-10
1.78

12

-5
1.91

13
14

-5
1.64

W/W
-35
0.87

c
11

10

W/W

COP (ASHRAE)
Comp.\C
SC15CL

COP (EN 12900/CECOMAF)


Comp.\C
SC15CL

a2

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC15CL

Starting relay

a2

117U6019

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.C2.02

CK.54.B6.02

August 2002

33

SC15DL
MBP/HBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.M2.02)
General
SC15DL

Code number

104L2856

104L

SC15DL
Application

R404A
R407C R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP/HBP

Barcode on
white background

-20 to 15

Yellow background

2856

DANFOSS COMPRESSORS

8306-5

Compressor

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

600

1300

cm3

1460

kg

13.5

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

550

21.8

Cut-in current HST

21.8

Resistance, main and start winding (25C)

3.5/12.2

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

219

213

B1

193

B2

110

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

August 2002

34

CF.54.M3.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

15.28

8257

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15DL

-20
759

-15
964

-10
1207

watt
-5
1493

0
1825

5
2210

7.2
2397

10
2652

Capacity (ASHRAE)
Comp.\C
SC15DL

-20
881

-15
1121

15
3156

a3
a2

watt
-10
1405

-5
1740

0
2131

5
2585

7.2
2807

10
3109

15
3710

c
8227

Power consumption
Comp.\C
SC15DL

-20
589

-15
659

watt
-10
722

-5
778

0
825

5
865

7.2
879

10
896

15
918

-10
3.79

-5
4.07

0
4.31

5
4.50

7.2
4.57

10
4.64

15
4.75

Current consumption
Comp.\C
SC15DL

-20
3.09

-15
3.46

COP (EN 12900/CECOMAF)


Comp.\C
SC15DL

-20
1.29

-15
1.46

-10
1.67

W/W
-5
1.92

0
2.21

5
2.56

7.2
2.73

10
2.96

COP (ASHRAE)
Comp.\C
SC15DL

-20
1.50

15
3.44

b
e

Start winding
5

a2

Main winding
Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3

W/W
-15
1.70

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-10
1.95

-5
2.24

0
2.58

EN 12900/CECOMAF
45C
32C
45C

5
2.99

7.2
3.19

10
3.47

15
4.04

Thermostat

Fan

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC15DL

a3

117-7028 (470 mm cable length)


117-7029 (550 mm cable length)
117-7032 (650 mm cable length)
103N2009

Starting device

Cover

Starting relay

a2

Starting capacitor

Run capacitor

Cord relief

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

Components
of
starting device
103N1004
118-1917
118-1918
118-1919

CF.54.M3.02

CK.54.B6.02

August 2002

35

SC18CL
LBP/MBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.D1.02)
General
SC18CL

Code number

104L2123

104L

SC18CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/MBP

Barcode on
white background

-45 to -5

Yellow background

2123

DANFOSS COMPRESSORS

8296-3

Compressor

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

600

1300

cm3

1460

kg

13.7

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

495

20.0

Cut-in current HST

20.0

Resistance, main and start winding (25C)

3.7/14.1

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

219

213

B1

193

B2

110

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

August 2002

36

CF.54.D2.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

17.69

8257

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC18CL

-45
167

-40
271

-35
395

watt
-30
542

-25
715

-23.3
781

-20
918

-15
1154

-10
1425

-5
1735

Capacity (ASHRAE)
Comp.\C
SC18CL

-45
193

-40
313

a3
a2

watt
-35
457

-30
628

-25
830

-23.3
907

-20
1067

-15
1342

-10
1659

-5
2022

c
8227

Power consumption
Comp.\C
SC18CL

-45
294

-40
376

watt
-35
455

-30
534

-25
615

-23.3
643

-20
700

-15
792

-10
894

-5
1008
d

Current consumption
Comp.\C
SC18CL

-45
2.61

-40
2.80

A
-35
3.02

-30
3.29

-25
3.60

-23.3
3.72

-20
3.96

-15
4.36

-10
4.80

-5
5.29

b
e

Start winding
5

a2

Main winding

COP (EN 12900/CECOMAF)


Comp.\C
SC18CL

-45
0.57

-40
0.72

-35
0.87

W/W
-30
1.01

-25
1.16

-23.3
1.21

-20
1.31

-15
1.46

-10
1.59

COP (ASHRAE)
Comp.\C
SC18CL

-45
0.66

-5
1.72

Winding
protector
1

2
N
L

2
N
L

W/W
-40
0.83

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-35
1.00

-30
1.18

-25
1.35

EN 12900/CECOMAF
45C
32C
45C

-23.3
1.41

-20
1.52

-15
1.69

-10
1.86

-5
2.01

Bleeder resistance

a3
M

Thermostat

Fan

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC18CL

a3

117-7012 (470 mm cable length)


117-7027 (550 mm cable length)
117-7046 (650 mm cable length)
117-7040 (1000 mm cable length)
103N2009

Starting device

Cover

Starting relay

a2

Starting capacitor 80 F

Run capacitor

Cord relief

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

Components
of
starting device
103N1004
118-1917
118-1918
118-1919

CF.54.D2.02

CK.54.B6.02

August 2002

37

SC21CL
LBP Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.E1.02)
General
SC21CL

Code number

104L2322

104L

SC21CL
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-45 to -10

Yellow background

2322

DANFOSS COMPRESSORS

8296-2

Compressor

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

600

1300

cm3

1460

kg

14.0

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

590

23.4

Cut-in current HST

23.4

Resistance, main and start winding (25C)

3.4/14.4

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

219

213

B1

193

B2

110

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

August 2002

38

CF.54.E2.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

20.95

8257

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC21CL

-45
226

-40
325

-35
455

watt
-30
617

-25
813

-23.3
887

-20
1042

-15
1306

Capacity (ASHRAE)
Comp.\C
SC21CL

-45
263

-40
378

-10
1606

a3
a2

watt
-35
529

-30
719

-25
947

-23.3
1033

-20
1215

-15
1524

-10
1876

c
8227

Power consumption
Comp.\C
SC21CL

-45
400

-40
462

watt
-35
534

-30
615

-25
702

-23.3
733

-20
795

-15
891

-10
989

-35
2.94

-30
3.31

-25
3.71

-23.3
3.86

-20
4.14

-15
4.58

-10
5.00

Current consumption
Comp.\C
SC21CL

-45
2.40

-40
2.63

COP (EN 12900/CECOMAF)


Comp.\C
SC21CL

-45
0.57

-40
0.70

-35
0.85

W/W
-30
1.00

-25
1.16

-23.3
1.21

-20
1.31

-15
1.47

COP (ASHRAE)
Comp.\C
SC21CL

-45
0.66

-10
1.62

b
e

Start winding
5

a2

Main winding
Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3

W/W
-40
0.82

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-35
0.99

-30
1.17

-25
1.35

EN 12900/CECOMAF
45C
32C
45C

-23.3
1.41

-20
1.53

-15
1.71

-10
1.90

Thermostat

Fan

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC21CL

a3

117-7012 (470 mm cable length)


117-7027 (550 mm cable length)
117-7040 (1000 mm cable length)
103N2009

Starting device

Cover

Starting relay

a2

Starting capacitor 80 F

Run capacitor

Cord relief

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

Components
of
starting device
103N1004
118-1917
118-1918
118-1919

CF.54.E2.02

CK.54.B6.02

August 2002

39

SC10/10CL
LBP/MBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.F1.02)
General
SC10/10CL

Code number

104L4087

Application
Application

LBP/MBP

Evaporating temperature range


Voltage range

-35 to -5

V/Hz

SC10/10CL
Application

104L

R404A
R507

Lilac stripe
Approvals

4087

Barcode on
white background

8297

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2820

kg

26.3

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 10.29

Motor
Motor size

watt

127

2 x 315

LRA (rated after 4 sec. UL984) HST*

12.6

Cut-in current HST*

12.6

Resistance, main and start winding (25C)

6.7/11.8

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

August 2002

40

CF.54.F2.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10/10CL

-35
336

-30
517

-25
730

watt
-23.3
810

-20
979

-15
1268

-10
1601

-5
1981
Starting relay
Starting capacitor

Comp.\C
SC10/10CL

-35
390

-30
600

watt
-25
847

-23.3
941

-20
1137

-15
1474

-10
1863

-25
701

-23.3
741

-20
821

-15
942

-10
1060

Power consumption

10 11
12

Main winding

-5
2309

14

1
2
N
L

-35
486

-30
587

1
2
N
L

watt

Current consumption
-35
3.82

-30
4.11

-23.3
4.55

-20
4.79

-15
5.18

-10
5.61

-23.3
1.09

-20
1.19

-15
1.35

-10
1.51

COP (EN 12900/CECOMAF)


Comp.\C
SC10/10CL

-35
0.69

-30
0.88

-25
1.04

13

14

1
2
N
L

Time delay relay


Thermostat 2

Fan

Safety pressure control

A
-25
4.43

12

Blue
Black
Brown

-5
1168
Thermostat

Comp.\C
SC10/10CL

Start winding
Winding
protector

1
2
N
L

2 1

Comp.\C
SC10/10CL

10 11
13

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

-5
6.08

Remove wire 1-2 if thermostat 2 is used

W/W
-5
1.70

service valve
seal ring

COP (ASHRAE)
Comp.\C
SC10/10CL

-35
0.80

W/W
-30
1.02

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-25
1.21

-23.3
1.27

-20
1.39

EN 12900/CECOMAF
45C
32C
45C

-15
1.57

-10
1.76

-5
1.98
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
pcs.

SC10/10CL

Starting relay

117U6003

Starting capacitor 80 F

117U5017

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

Devices

September 2002

CF.54.F2.02

CK.54.B6.02

August 2002

41

SC10/10DL
MBP/HBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.N2.02)
General
SC10/10DL

Code number

104L4091

Application
Application

MBP/HBP

Evaporating temperature range


Voltage range

-20 to 15

V/Hz

SC10/10DL
Application

104L

R404A
R407C R507

Lilac stripe
Approvals

4091

Barcode on
white background

8307

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2820

kg

26.8

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 10.29

Motor
Motor size

watt

127

2 x 385

LRA (rated after 4 sec. UL984) HST*

14.8

Cut-in current HST*

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

August 2002

42

CF.54.N3.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10/10DL

-20
943

-15
1222

-10
1550

watt

-5
0
1935 2383

5
2900

7.2
3152

10
3494

15
4169
Starting relay
Starting capacitor
10 11

Comp.\C
-20
SC10/10DL 1095

-15
1420

watt
-10
-5
1804 2256

0
2782

5
3392

7.2
3690

10
4095

-10
957

0
1118

5
1180

7.2
1203

10
1228

Power consumption

12

Main winding

15
4901

14

1
2
N
L

-20
747

-15
858

1
2
N
L

watt
-5
1044

Current consumption
-15
5.55

-5
6.30

0
6.60

5
6.85

7.2
6.95

10
7.06

-5
1.85

0
2.13

5
2.46

7.2
2.62

10
2.85

COP (EN 12900/CECOMAF)


Comp.\C
-20
SC10/10DL 1.26

-15
1.42

13

14

1
2
N
L

Time delay relay


Thermostat 2

Fan

Safety pressure control

A
-10
5.95

12

Blue
Black
Brown

15
1262
Thermostat

Comp.\C
-20
SC10/10DL 5.11

Start winding
Winding
protector

1
2
N
L

2 1

Comp.\C
SC10/10DL

10 11
13

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

15
7.21

Remove wire 1-2 if thermostat 2 is used

W/W

-10
1.62

15
3.30

service valve
seal ring

COP (ASHRAE)
Comp.\C
-20
SC10/10DL 1.47

W/W
-15
1.66

-10
1.89

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-5
2.16

0
2.49

5
2.88

EN 12900/CECOMAF
45C
32C
45C

7.2
3.07

10
3.34

15
3.88
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
pcs.

SC10/10DL

Starting relay

117U6005

Starting capacitor 80 F

117U5017

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

Devices

September 2002

CF.54.N3.02

CK.54.B6.02

August 2002

43

SC12/12CL
LBP/MBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.G1.02)
General
SC12/12CL

Code number

104L4088

Application
Application

LBP/MBP

Evaporating temperature range


Voltage range

-45 to -5

V/Hz

SC12/12CL
Application

104L

R404A
R507

Lilac stripe
Approvals

4088

Barcode on
white background

8297-4

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2820

kg

27.3

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 12.87

Motor
Motor size

watt

127

2 x 385

LRA (rated after 4 sec. UL984) HST*

14.8

Cut-in current HST*

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

August 2002

44

CF.54.G2.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
-45
SC12/12CL 115

-40
279

-35
475

-30
706

watt
-25 -23.3 -20 -15 -10
-5
980 1083 1299 1670 2096 2583
Starting relay
Starting capacitor

Comp.\C
-45
SC12/12CL 134

-40
323

watt
-35
550

-30 -25 -23.3 -20 -15 -10


-5
819 1137 1257 1509 1941 2440 3011

-35
633

-30
761

Power consumption

10 11
12

Main winding
14

1
2
N
L

-40
506

Start winding
Winding
protector

1
2
N
L

1
2
N
L

watt
2 1

Comp.\C
-45
SC12/12CL 379

10 11
13

Current consumption

COP (EN 12900/CECOMAF)

1
2
N
L

Time delay relay


Thermostat 2

Fan

Safety pressure control

Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC12/12CL 4.30 4.55 4.85 5.22 5.64 5.80 6.13 6.67 7.27 7.94

13

14

Blue
Black
Brown

-25 -23.3 -20 -15 -10


-5
891 936 1024 1163 1308 1460
Thermostat

12

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

Remove wire 1-2 if thermostat 2 is used

W/W

Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC12/12CL 0.30 0.55 0.75 0.93 1.10 1.16 1.27 1.44 1.60 1.77

service valve
seal ring

COP (ASHRAE)

W/W

Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC12/12CL 0.35 0.64 0.87 1.08 1.28 1.34 1.47 1.67 1.87 2.06
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC12/12CL

Starting relay

117U6005

Starting capacitor 80 F

117U5017

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CF.54.G2.02

CK.54.B6.02

August 2002

45

SC12/12DL
MBP/HBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.O2.02)
General
SC12/12DL

Code number

104L4092

Application
Application

MBP/HBP

Evaporating temperature range


Voltage range

-20 to 15

V/Hz

SC12/12DL
Application

104L

R404A
R407C R507

Lilac stripe
Approvals

4092

Barcode on
white background

8307-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2920

kg

27.8

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 12.87

Motor
Motor size

watt

127

2 x 495

LRA (rated after 4 sec. UL984) HST*

18.6

Cut-in current HST*

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

August 2002

46

CF.54.O3.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
-20
SC12/12DL 1217

-15
-10
1612 2055

watt

-5
2559

0
3130

5
3780

7.2
4092

10
4516

15
5348
Starting relay
Starting capacitor
10 11

Comp.\C
-20
SC12/12DL 1414

watt

-15
-10
1874 2393

-5
2982

0
3654

5
4421

7.2
10
4791 5294

-5
1349

0
1433

5
1500

7.2
1526

Power consumption

12

Main winding

15
6287

14

1
2
N
L

-20
978

-15
1125

1
2
N
L

watt
-10
1248

10
1555

Current consumption
-15
7.29

-5
8.21

0
8.58

5
8.88

7.2
9.00

10
9.13

-5
1.90

0
2.18

5
2.52

7.2
2.68

10
2.90

COP (EN 12900/CECOMAF)


Comp.\C
-20
SC12/12DL 1.24

-15
1.43

-10
1.65

13

14

1
2
N
L

Time delay relay


Thermostat 2

Fan

Safety pressure control

A
-10
7.78

12

Blue
Black
Brown

15
1600
Thermostat

Comp.\C
-20
SC12/12DL 6.74

Start winding
Winding
protector

1
2
N
L

2 1

Comp.\C
SC12/12DL

10 11
13

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

15
9.31

Remove wire 1-2 if thermostat 2 is used

W/W
15
3.34

service valve
seal ring

COP (ASHRAE)
Comp.\C
-20
SC12/12DL 1.45

W/W
-15
1.67

-10
1.92

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-5
2.21

0
2.55

5
2.95

EN 12900/CECOMAF
45C
32C
45C

7.2
3.14

10
3.40

15
3.93
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
pcs.

SC12/12DL

Starting relay

117U6019

Starting capacitor 80 F

117U5017

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

Devices

September 2002

CF.54.O3.02

CK.54.B6.02

August 2002

47

SC15/15CL
LBP/MBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.H1.02)
General
SC15/15CL

Code number

104L4089

Application
Application

LBP/MBP

Evaporating temperature range


Voltage range

-40 to -5

V/Hz

SC15/15CL
Application

104L

R404A
R507

Lilac stripe
Approvals

4089

Barcode on
white background

8297-5

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2920

kg

29.1

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 15.28

Motor
Motor size

watt

127

2 x 495

LRA (rated after 4 sec. UL984) HST*

18.6

Cut-in current HST*

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

259

254

B1

193

B2

110

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

August 2002

48

CF.54.H2.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15/15CL

-40
302

-35
599

-30
905

watt

-25 -23.3
1230 1347

-20
1584

-15
-10
1976 2417

-5
2916
Starting relay
Starting capacitor

Comp.\C
SC15/15CL

-40
350

-35
694

watt
-30
1050

-25 -23.3
1428 1563

-20
-15
1840 2298

-30
970

-25 -23.3
1120 1169

-20
1262

-10
2813

Power consumption

10 11
12

Main winding

-5
3398

14

1
2
N
L

-40
597

-35
801

1
2
N
L

watt
-15
-10
1411 1580

Current consumption
-35
6.10

-25
7.04

-23.3
7.21

-20
7.55

-15
8.08

-10
8.62

-25
1.10

-23.3
1.15

-20
1.25

-15
1.40

-10
1.53

COP (EN 12900/CECOMAF)


Comp.\C
-40
SC15/15CL 0.51

-35
0.75

-30
0.93

13

14

1
2
N
L

Time delay relay


Thermostat 2

Fan

Safety pressure control

A
-30
6.56

12

Blue
Black
Brown

-5
1782
Thermostat

Comp.\C
-40
SC15/15CL 5.66

Start winding
Winding
protector

1
2
N
L

2 1

Comp.\C
SC15/15CL

10 11
13

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

-5
9.19

Remove wire 1-2 if thermostat 2 is used

W/W
-5
1.64

service valve
seal ring

COP (ASHRAE)
Comp.\C
-40
SC15/15CL 0.59

W/W
-35
0.87

-30
1.08

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-25
1.27

-23.3
1.34

-20
1.46

EN 12900/CECOMAF
45C
32C
45C

-15
1.63

-10
1.78

-5
1.91
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC15/15CL

117U6019

Starting capacitor 80 F

117U5017

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

Starting relay

September 2002

CF.54.H2.02

CK.54.B6.02

August 2002

49

SC15/15DL
MBP/HBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.P2.02)
General
SC15/15DL

Code number

104L4093

Application
Application

MBP/HBP

Evaporating temperature range


Voltage range

-20 to 15

V/Hz

SC15/15DL
Application

104L

R404A
R407C R507

Lilac stripe
Approvals

4093

Barcode on
white background

8307-2

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2920

kg

28.0

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 15.28

Motor
Motor size

watt

127

2 x 550

LRA (rated after 4 sec. UL984) HST*

21.8

Cut-in current HST*

21.8

Resistance, main and start winding (25C)

3.5/12.1

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

259

254

B1

193

B2

110

B1
B2

1"-14 UNF

location/I.D. mm

16

Solder connector

location/I.D. mm

16

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8265

18

326

August 2002

50

CF.54.P3.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


-15
-10
1928 2414

watt

-5
2985

0
5
3651 4420

7.2
4795

10
5304

-5
3479

0
4262

7.2
5613

10
6218

Capacity (ASHRAE)
Comp.\C
-20
-15
SC15/15DL 1763 2242

-15
1319

5
5170

15
7419

-15
6.93

-10
1445

-5
1556

0
5
1651 1730

7.2
1760

10
1793

-10
7.58

-5
8.14

0
8.61

5
9.00

7.2
9.14

10
9.29

-15
1.46

-5
1.92

0
2.21

5
2.55

7.2
2.72

10
2.96

15
9.50

1
2
N
L

15
1837

COP (EN 12900/CECOMAF)


Comp.\C
-20
SC15/15DL 1.29

1
2
N
L

watt

Current consumption
Comp.\C
-20
SC15/15DL 6.19

Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance

watt
-10
2810

Power consumption
Comp.\C
-20
SC15/15DL 1178

15
6311

1
2
N
L

2 1

Thermostat

1932

Comp.\C
-20
SC15/15DL 1518

1
2
N
L

Blue
Black
Brown

Time delay
relay
Safety pressure control

Remove wire L-1 if time delay is used

Fan

Thermostat 2

Remove wire 1-2 if thermostat 2 is used

W/W

-10
1.67

15
3.43

service valve
seal ring

COP (ASHRAE)
Comp.\C
-20
SC15/15DL 1.50

W/W
-15
1.70

-10
1.94

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-5
2.24

0
2.58

5
2.99

EN 12900/CECOMAF
45C
32C
45C

7.2
3.19

10
3.47

15
4.04
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC15/15DL

117-7028 (470 mm cable length)


117-7029 (550 mm cable length)
117-7032 (650 mm cable length)

Starting device

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7351
(16 mm)

Solder connector (alternative)

118-7405
(16 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CF.54.P3.02

CK.54.B6.02

August 2002

51

SC18/18CL
LBP/MBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.I1.02)
General
SC18/18CL

Code number

104L4090

Application
Application

LBP/MBP

Evaporating temperature range


Voltage range

-45 to -5

V/Hz

SC18/18CL
Application

104L

R404A
R507

Lilac stripe
Approvals

4090

Barcode on
white background

8297-2

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2920

kg

29.1

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 17.69

Motor
Motor size

watt

127

2 x 495

LRA (rated after 4 sec. UL984) HST*

20.0

Cut-in current HST*

20.0

Resistance, main and start winding (25C)

3.7/14.1

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

259

254

B1

193

B2

110

B1
B2

1"-14 UNF

location/I.D. mm

16

Solder connector

location/I.D. mm

16

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8265

18

326

August 2002

52

CF.54.I2.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


-40
541

watt

-35 -30 -25 -23.3 -20 -15 -10


-5
789 1083 1430 1562 1836 2307 2849 3469

Capacity (ASHRAE)
Comp.\C
-45
SC18/18CL 386

watt

-40
627

-35 -30 -25 -23.3 -20 -15 -10


-5
915 1256 1660 1813 2133 2683 3317 4043

Power consumption

watt

Comp.\C
-45
SC18/18CL 587

-40
752

Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance

1
2
N
L

Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC18/18CL 5.22 5.59 6.04 6.58 7.21 7.44 7.92 8.72 9.61 10.58

COP (EN 12900/CECOMAF)


Comp.\C
-45 -40 -35
SC18/18CL 0.57 0.72 0.87

1
2
N
L

-35 -30 -25 -23.3 -20 -15 -10


-5
910 1068 1230 1286 1400 1585 1788 2015

Current consumption

1
2
N
L

2 1

Thermostat

1932

Comp.\C
-45
SC18/18CL 333

1
2
N
L

Blue
Black
Brown

Time delay
relay
Safety pressure control

Remove wire L-1 if time delay is used

Fan

Thermostat 2

Remove wire 1-2 if thermostat 2 is used

W/W
-30 -25 -23.3 -20 -15 -10
-5
1.01 1.16 1.21 1.31 1.46 1.59 1.72

service valve
seal ring

COP (ASHRAE)

W/W

Comp.\C
-45 -40 -35 -30 -25 -23.3 -20 -15 -10
-5
SC18/18CL 0.66 0.83 1.00 1.18 1.35 1.41 1.52 1.69 1.85 2.01
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
45C

seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices
Starting device

pcs.

SC18/18CL

117-7012 (470 mm cable length)


117-7027 (550 mm cable length)

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7351
(16 mm)

Solder connector (alternative)

118-7405
(16 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CF.54.I2.02

CK.54.B6.02

August 2002

53

SC21/21CL
LBP Twin Compressor
R404A/R507
220-240V 50Hz
Data Sheet (Replaces CF.54.J1.02)
General
SC21/21CL

Code number

104L4094

Application
Application

LBP

Evaporating temperature range


Voltage range

-45 to -10

V/Hz

SC21/21CL
Application

104L

R404A
R507

Lilac stripe
Approvals

4094

Barcode on
white background

8297-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2920

kg

29.1

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 20.95

Motor
Motor size

watt

127

2 x 590

LRA (rated after 4 sec. UL984) HST*

23.4

Cut-in current HST*

23.4

Resistance, main and start winding (25C)

3.4/14.4

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

259

254

B1

193

B2

110

B1
B2

1"-14 UNF

location/I.D. mm

16

Solder connector

location/I.D. mm

16

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8265

18

326

August 2002

54

CF.54.J2.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


-45
452

-40
650

watt

-35
910

-30
1235

-25 -23.3 -20


1626 1774 2084

-15
2613

-35
1059

-30
1437

-25 -23.3 -20


1893 2068 2430

-15
3049

Capacity (ASHRAE)
Comp.\C
SC21/21CL

-45
525

-40
755

-45
799

-40
924

-10
3753

-40
5.27

-35
1068

-30
1230

-25 -23.3
1404 1466

-20
1589

-15
1782

-35
5.88

-30
6.61

-25
7.42

-23.3
7.71

-20
8.28

-15
9.15

-40
0.70

-35
0.85

-30
1.00

-25
1.16

-23.3
1.21

-20
1.31

-15
1.47

-10
9.99

1
2
N
L

-10
1978

COP (EN 12900/CECOMAF)


Comp.\C
-45
SC21/21CL 0.57

1
2
N
L

watt

Current consumption
Comp.\C
-45
SC21/21CL 4.80

Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance

watt

Power consumption
Comp.\C
SC21/21CL

-10
3213

1
2
N
L

2 1

Thermostat

1932

Comp.\C
SC21/21CL

1
2
N
L

Blue
Black
Brown

Time delay
relay
Safety pressure control

Remove wire L-1 if time delay is used

Fan

Thermostat 2

Remove wire 1-2 if thermostat 2 is used

W/W
-10
1.62

service valve
seal ring

COP (ASHRAE)
Comp.\C
-45
SC21/21CL 0.66

W/W
-40
0.82

-35
0.99

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-30
1.17

-25
1.35

-23.3
1.41

EN 12900/CECOMAF
45C
32C
45C

-20
1.53

-15
1.71

-10
1.90
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices
Starting device

pcs.

SC21/21CL

117-7012 (470 mm cable length)


117-7027 (550 mm cable length)

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7351
(16 mm)

Solder connector (alternative)

118-7405
(16 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CF.54.J2.02

CK.54.B6.02

August 2002

55

SC12CLX
LBP Compressor
R404A/R507
220-240V 60Hz
Data Sheet (Replaces CF.54.T2.02)
General
SC12CLX

Code number

104L2695

104L

SC12CLX
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-40 to -10

Yellow background

2695

DANFOSS COMPRESSORS

198 - 254 /60


CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

SC12CLX
230V-60Hz
1PH
THERMALLY
PROTECTED

Approval mark

Design
Displacement

cm3

Oil quantity

cm3

550

1300

cm3

1510

kg

13.7

Free gas vol. in compressor


Weight without electrical equipment

S
O
F1

12.87

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

495

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

70
150

Motor size

UL984/CSA-C22.2

127
165
186
218

D
Dimensions

location/I.D. mm

219

213

B1

193

B2

110

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Suction connector

mm

19
9.7

127
101.6
35

Motor

37

37

107

September 2002

56

CF.54.T3.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

Height

8349-5

Motor type

8349-2

Compressor

8258

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC12CLX

-40
146

-35
282

-30
429

watt
-25
590

-23.3
649

-20
770

-15
972

-10
1200
c

Capacity (ASHRAE)
Comp.\C
SC12CLX

-40
169

-35
327

watt
-30
497

-25
685

-23.3
753

-20
894

-15
1130

-10
1397
b
8222

Power consumption
Comp.\C
SC12CLX

-40
277

-35
376

watt
-30
462

-25
540

-23.3
566

-20
616

-15
696

-10
784

a2
d

Current consumption
Comp.\C
SC12CLX

-40
2.58

-35
2.75

A
-30
2.96

-25
3.23

-23.3
3.33

-20
3.54

-15
3.91

-10
4.32

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC12CLX

-40
0.53

W/W

-35
0.75

-30
0.93

-25
1.09

-23.3
1.15

-20
1.25

-15
1.40

-35
0.87

-30
1.08

-25
1.27

-23.3
1.33

-20
1.45

-15
1.62

COP (ASHRAE)
Comp.\C
SC12CLX

-40
0.61

-10
1.53

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz

EN 12900/CECOMAF
45C
32C
45C

-10
1.78

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC12CLX

Starting relay

a2

117U6019
103N2008

Cover

Starting capacitor 80 F

117U5019

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.T3.02

CK.54.B6.02

September 2002

57

SC15CLX
LBP Compressor
R404A/R507
220-240V 60Hz
Data Sheet (Replaces CF.54.R2.02)
General
SC15CLX

Code number

104L2854

104L

SC15CLX
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-40 to -10

Yellow background

2854

DANFOSS COMPRESSORS

198 - 254 /60

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

SC15CLX
230V-60Hz
1PH
8349-6

Motor type

THERMALLY
PROTECTED

Approval mark

Design
Displacement

cm3

Oil quantity

cm3

550

1300

cm3

1510

kg

13.7

Free gas vol. in compressor


Weight without electrical equipment

S
O
F1

15.28

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

550

21.8

Cut-in current HST

21.8

Resistance, main and start winding (25C)

3.5/12.1

Approvals

70
150

Motor size

UL984/CSA-C22.2

127
165
186
218

D
Dimensions

location/I.D. mm

219

213

B1

193

B2

110

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Suction connector

mm

19
9.7

127
101.6
35

Motor

37

37

107

September 2002

58

CF.54.R3.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

Height

8349

Compressor

8257

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15CLX

-40
179

-35
351

-30
530

watt
-25
720

-23.3
788

-20
928

-15
1158

Capacity (ASHRAE)
Comp.\C
SC15CLX

-40
208

-35
407

-10
1417

a3
a2

watt
-30
614

-25
836

-23.3
915

-20
1078

-15
1347

-10
1649

c
8227

Power consumption
Comp.\C
SC15CLX

-40
303

-35
414

watt
-30
515

-25
610

-23.3
641

-20
699

-15
783

-10
864

-30
2.46

-25
2.90

-23.3
3.05

-20
3.33

-15
3.73

-10
4.11

Current consumption
Comp.\C
SC15CLX

-40
1.51

-35
1.99

COP (EN 12900/CECOMAF)


Comp.\C
SC15CLX

-40
0.59

-35
0.85

-30
1.03

W/W
-25
1.18

-23.3
1.23

-20
1.33

-15
1.48

COP (ASHRAE)
Comp.\C
SC15CLX

-40
0.68

-10
1.64

b
e

Start winding
5

a2

Main winding
Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3

W/W
-35
0.98

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz

-30
1.19

-25
1.37

-23.3
1.43

EN 12900/CECOMAF
45C
32C
45C

-20
1.54

-15
1.72

-10
1.91

Thermostat

Fan

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC15CLX

a3

117-7038 (470 mm cable lenght)


117-7039 (550 mm cable lenght)
117-7043 (1000 mm cable lenght)
103N2008

Starting device

Cover

Starting relay

a2

Starting capacitor

Run capacitor

Cord relief

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

Components of
starting device
103N1004
118-1917
118-1918
118-1919

CF.54.R3.02

CK.54.B6.02

September 2002

59

SC10/10CLX
LBP/MBP Twin Compressor
R404A/R507
220-240V 60Hz
Data Sheet
General
SC10/10CLX

Code number

104L4033

Application
Application

LBP/MBP

Evaporating temperature range


Voltage range

-35 to -5

V/Hz

SC10/10CLX
Application

104L

R404A
R507

Lilac stripe
Approvals

4033

Barcode on
white background

8461

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /60

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2820

kg

26.8

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 10.29

Motor
Motor size

watt

127

2 x 385

LRA (rated after 4 sec. UL984) HST*

14.8

Cut-in current HST*

14.8

Resistance, main and start winding (25C)

16

175

302

5.0/13.7

Approvals

* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

January 2002

60

CJ.54.F1.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10/10CLX

-35
448

-30
670

-25
910

watt
-23.3
998

-20
1176

-15
1476

-10
1812

-5
2192
Starting relay
Starting capacitor
10 11

Comp.\C
SC10/10CLX

-35
520

watt
-30
776

-25
1056

-23.3
1158

-20
1366

-15
1714

-10
2108

-25
860

-23.3
900

-20
978

-15
1104

-10
1246

Power consumption
Comp.\C
SC10/10CLX

-35
608

-30
740

-35
4.38

-30
4.72

-35
0.74

-30
0.90

1
2
N
L

-20
9.78

-15
6.04

-10
6.60

-25
1.06

-23.3
1.11

-20
1.20

-15
1.34

-10
1.45

1
2
N
L

2 1

-5
1414

Start winding
Winding
protector

1
2
N
L

Thermostat

12

13

14

1
2
N
L

Blue
Black
Brown

Time delay relay


Thermostat 2

Fan

Safety pressure control

A
-23.3
5.24

COP (EN 12900/CECOMAF)


Comp.\C
SC10/10CLX

14

watt

-25
5.10

10 11
13

Main winding

-5
2554

Current consumption
Comp.\C
SC10/10CLX

12

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

-5
7.22

Remove wire 1-2 if thermostat 2 is used

W/W
-5
1.55

service valve
seal ring

COP (ASHRAE)
Comp.\C
SC10/10CLX

-35
0.85

W/W
-30
1.05

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz

-25
1.23

-23.3
1.29

-20
1.40

EN 12900/CECOMAF
45C
32C
45C

-15
1.55

-10
1.69

-5
1.81
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC10/10CLX

Starting relay

117U6005

Starting capacitor 80 F

117U5019

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CJ.54.F1.02

CK.54.B6.02

January 2002

61

SC12/12CLX
LBP Twin Compressor
R404A/R507
220-240V 60Hz
Data Sheet
General
SC12/12CLX

Code number

104L4034

Application
Application

LBP

Evaporating temperature range


Voltage range

-40 to -10

V/Hz

SC12/12CLX
Application

104L

R404A
R507

Lilac stripe
Approvals

4034

Barcode on
white background

8461-2

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /60

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2820

kg

28.0

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 12.87

Motor
Motor size

watt

127

2 x 495

LRA (rated after 4 sec. UL984) HST*

18.6

Cut-in current HST*

18.6

Resistance, main and start winding (25C)

16

175

302

3.7/14.1

Approvals

* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

259

254

B1

193

B2

100

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

January 2002

62

CJ.54.G1.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC12/12CLX

-40
292

-35
564

-30
858

watt
-25
1180

-23.3
1298

-20
1540

-15
1944

-10
2400
Starting relay
Starting capacitor
10 11

Comp.\C
SC12/12CLX

-40
338

watt
-35
654

-30
994

-25
1370

-23.3
1506

-20
1788

-15
2260

-30
924

-25
1080

-23.3
1132

-20
1232

-15
1392

Power consumption
Comp.\C
SC12/12CLX

-40
554

-35
752

-40
5.16

-35
5.50

-40
0.53

-35
0.75

1
2
N
L

-23.3
6.66

-20
7.08

-15
7.82

-30
0.93

-25
1.09

-23.3
1.15

-20
1.25

-15
1.40

1
2
N
L

2 1

-10
1568

Start winding
Winding
protector

1
2
N
L

Thermostat

12

13

14

1
2
N
L

Blue
Black
Brown

Time delay relay


Thermostat 2

Fan

Safety pressure control

A
-25
6.46

COP (EN 12900/CECOMAF)


Comp.\C
SC12/12CLX

14

watt

-30
5.92

10 11
13

Main winding

-10
2794

Current consumption
Comp.\C
SC12/12CLX

12

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

-10
8.64

Remove wire 1-2 if thermostat 2 is used

W/W
-10
1.53

service valve
seal ring

COP (ASHRAE)
Comp.\C
SC12/12CLX

-40
0.61

W/W
-35
0.87

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz

-30
1.08

-25
1.27

-23.3
1.33

EN 12900/CECOMAF
45C
32C
45C

-20
1.45

-15
1.62

-10
1.78
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC12/12CLX

Starting relay

117U6019

Starting capacitor 80 F

117U5019

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CJ.54.G1.02

CK.54.B6.02

January 2002

63

SC15/15CLX
LBP Twin Compressor
R404A/R507
220-240V 60Hz
Data Sheet
General
SC15/15CLX

Code number

104L4097

Application
Application

LBP

Evaporating temperature range


Voltage range

-40 to -10

V/Hz

SC15/15CLX
Application

104L

R404A
R507

Lilac stripe
Approvals

4097

Barcode on
white background

8461-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /60

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2920

kg

28.0

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 15.28

Motor
Motor size

watt

127

2 x 550

LRA (rated after 4 sec. UL984) HST*

21.8

Cut-in current HST*

21.8

Resistance, main and start winding (25C)

16

175

302

3.5/12.1

Approvals

* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

259

254

B1

193

B2

110

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8265

18

326

January 2002

64

CJ.54.H1.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


-40
358

watt

-35
702

-30
1060

-25
1440

-23.3
1576

-20
1856

-15
2316

-10
2834

-35
814

-30
1228

-25
1672

-23.3
1830

-20
2156

-15
2694

-10
3298

Capacity (ASHRAE)
Comp.\C
SC15/15CLX

-40
416

watt

Power consumption
Comp.\C
SC15/15CLX

-40
606

Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance

-35
828

1
2
N
L

watt
-30
1030

-25
1220

-23.3
1282

-20
1398

-15
1566

-40
3.02

-35
3.98

A
-30
4.92

-25
5.80

-23.3
6.10

-20
6.66

-15
7.46

-25
1.18

-23.3
1.23

-20
1.33

-15
1.48

COP (EN 12900/CECOMAF)


Comp.\C
SC15/15CLX

-40
0.59

-35
0.85

-30
1.03

1
2
N
L

2 1

Thermostat

Comp.\C
SC15/15CLX

1
2
N
L

-10
1728

Current consumption

-10
8.22

1932

Comp.\C
SC15/15CLX

1
2
N
L

Blue
Black
Brown

Time delay
relay
Safety pressure control

Remove wire L-1 if time delay is used

Fan

Thermostat 2

Remove wire 1-2 if thermostat 2 is used

W/W
-10
1.64

service valve
seal ring

COP (ASHRAE)
Comp.\C
SC15/15CLX

-40
0.68

W/W
-35
0.98

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 60Hz

-30
1.19

-25
1.37

-23.3
1.43

EN 12900/CECOMAF
45C
32C
45C

-20
1.54

-15
1.72

-10
1.91
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC15/15CLX

117-7028 (470 mm cable length)


117-7029 (550 mm cable length)
117-7032 (650 mm cable length)

Starting device

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CJ.54.H1.02

CK.54.B6.02

January 2002

65

SC10CLX
LBP/MBP Compressor
R404A/R507
220-240V 50/60Hz
Data Sheet (Replaces CF.54.S2.02)
General
SC10CLX

Code number

104L2533

Code number

104L2536

104L

SC10CLX
Application

R404A
R507

Lilac stripe
Approvals

2533

Barcode on
white background

Application
Application

LBP/MBP

Evaporating temperature range

DANFOSS COMPRESSORS

Yellow background

8349

Compressor

50Hz: -35 to 5
60Hz: -35 to -5

SC10CLX

LBP/MBP: 198 - 254 /50

208-230V-60Hz

LBP: 198 - 254 /60


Motor type

1PH

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

THERMALLY
PROTECTED

Approval mark

38C

F2

S
O
F1

cm3

10.29

F2

Design
Displacement
Oil quantity

550

1300

cm3

1460

kg

13.1

cm

Maximum refrigerant charge


Free gas vol. in compressor

Motor size

watt

385

LRA (rated after 4 sec. UL984) HST

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)

70
150

104L2536

209

203

B1

183

B A

B1
B2

100
8.2 0.09

location/I.D. mm

6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

6.2 0.09

6.5 0.09
80

63

Process connector

55

151

8.2 0.09

255

location/I.D. mm

pcs.

104L2533
mm

B2

37

37

107

September 2002

66

UL984/CSA-C22.2

Dimensions

Compressors on a pallet

19
9.7

127
165
186
218

5.0/13.7

Approvals

Suction connector

204
178
170

16

Motor

Height

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

127
101.6
35

Weight without electrical equipment

8349-8

V/Hz

CF.54.S3.02

CK.54.B6.02

107
115

55
63

Voltage range

8258

September 2002

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC10CLX, 50Hz
SC10CLX, 60Hz

-35
166
224

-30
255
335

-25
360
455

watt
-23.3
400
499

-20
483
588

-15
625
738

-10
789
906

-5
977
1096

0
1190

Capacity (ASHRAE)
Evap. temp in C
SC10CLX, 50Hz
SC10CLX, 60Hz

-35
192
260

5
1430

watt
-30
296
388

-25
418
528

-23.3
464
579

-20
561
683

-15
727
857

-10
919
1054

-5
1139
1277

0
1389

5
1673
b
8222

Power consumption
Evap. temp in C
SC10CLX, 50Hz
SC10CLX, 60Hz

-35
258
304

watt
-30
302
370

-25
352
430

-23.3
369
450

-20
404
489

-15
457
552

-10
508
623

-5
556
707

0
597

5
631
d

Current consumption
Evap. temp in C -35
SC10CLX, 50Hz 2.00
SC10CLX, 60Hz 2.19

a2

A
-30
2.15
2.36

-25
2.32
2.55

-23.3
2.38
2.62

-20
2.51
2.77

-15
2.72
3.02

-10
2.94
3.30

-5
3.19
3.61

0
3.45

5
3.73

c
11

10

COP (EN 12900/CECOMAF)


Evap. temp in C -35
SC10CLX, 50Hz 0.64
SC10CLX, 60Hz 0.74

W/W

-30
0.84
0.90

-25
1.02
1.06

-23.3
1.08
1.11

-20
1.20
1.20

-15
1.37
1.34

-10
1.55
1.45

-5
1.76
1.55

0
1.99

-30
0.98
1.05

-25
1.19
1.23

-23.3
1.26
1.29

-20
1.39
1.40

-15
1.59
1.55

-10
1.81
1.69

-5
2.05
1.81

0
2.33

COP (ASHRAE)
Evap. temp in C -35
SC10CLX, 50Hz 0.75
SC10CLX, 60Hz 0.85

5
2.27

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
45C
32C
45C

5
2.65

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC10CLX

Starting Relay

a2

117U6005
103N2008

Cover

Starting capacitor 80 F

117U5019

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.S3.02

CK.54.B6.02

September 2002

67

SC10MLX
MBP Compressor
R404A/R507
220-240V 50Hz & 208-230V 60Hz
Data Sheet
General
SC10MLX

Code number

104L2506

104L

SC10MLX
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range

C (F)

Voltage range

V/Hz

MBP

Barcode on
white background

-23.3 to 7.2 (-10 to 45)

Yellow background

2506

DANFOSS COMPRESSORS

187 - 254 /50

8365

Compressor

187 - 254 /60

SC10MLX

CSIR
C (F)

208-230V-60Hz

43 (110)

Comp. cooling at ambient temp. 32C (90F)

F2

38C (100F)

F2

43C (110F)

F2

1PH
THERMALLY
PROTECTED

Approval mark
S
O
F1

Design
cm3

10.29

Oil quantity

cm3

600

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

1300

cm3

1410

kg

13.1

Motor
Motor size

watt

470

LRA (rated after 4 sec. UL984) HST

18.4

Cut-in current HST

18.4

Resistance, main and start winding (25C)


Approvals

4.3/15.3

F2

204
178
170

16

19
9.7

127
101.6
35

Displacement

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

70
150

Max. ambient temperature

8465-2

Motor type

127
165
186
218

EN 60335-2-34, UL984/CSA-C22.2

C
E

Dimensions

B1

183

B2

100

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.5 0.09

Discharge connector

location/I.D. mm

6.5 0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

209
203

37

37

107

August 2002

68

CJ.54.L1.02

CK.54.B6.02

107
115

55
63

A
B

mm

151

Height

8258

September 2002

Conditions: ASHRAE MBP 60Hz


Evap. temp inF
Evap. temp inC
Capacity in Btu/h
Power cons. in W
Current cons. in A
EER in Btu/Wh

-10
-23.3
1538
462
2.88
3.33

0
-17.8
2118
542
3.15
3.91

10
-12.2
2796
619
3.45
4.52

14
-10.0
3099
650
3.58
4.77

20
-6.7
3590
697
3.79
5.15

30
-1.1
4517
778
4.18
5.80

40
4.4
5597
867
4.60
6.45

45
7.2
6200
916
4.83
6.77

10
-12.2
2386
536
3.70
4.45

14
-10.0
2636
557
3.78
4.73

20
-6.7
3043
587
3.90
5.18

30
-1.1
3817
638
4.12
5.99

40
4.4
4721
687
4.36
6.87

45
7.2
5227
712
4.49
7.34

0
32
1510
740
4.02
2.04

5
41
1812
817
4.36
2.22

0
32
1278
594
3.96
2.15

5
41
1537
633
4.14
2.43

Conditions: ASHRAE MBP 50Hz


Evap. temp inF
Evap. temp inC
Capacity in Btu/h
Power cons. in W
Current cons. in A
EER in Btu/Wh

-10
-23.3
1362
428
3.35
3.18

0
-17.8
1830
483
3.52
3.79

b
8222

a2
d

Conditions: EN 12900/CECOMAF (no subcooling) 60Hz


Evap. temp inC
Evap. temp inF
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W

-23.3
-10
547
470
2.87
1.16

-20
-4
646
504
2.99
1.28

-15
5
816
557
3.20
1.47

-10
14
1015
612
3.44
1.66

-6.7
20
1164
651
3.62
1.79

-5
23
1246
672
3.72
1.85

c
11

10

12

13
14

Conditions: EN 12900/CECOMAF (no subcooling) 50Hz


Evap. temp inC
Evap. temp inF
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W

-23.3
-10
465
416
3.31
1.12

-20
-4
546
442
3.39
1.23

-15
5
687
481
3.51
1.43

Test conditions
EN 12900/CECOMAF
Condensing temperature 45C
Return gas temperature
32C
Liquid temperature
45C
50Hz: Fan cooling F2 , 220V
60Hz: Fan cooling F2 , 230V

-10
14
855
518
3.65
1.65

-6.7
20
981
543
3.75
1.81

-5
23
1051
556
3.80
1.89

Start winding
Main winding
Winding protector

ASHRAE
54.4C
35.0C
46.1C

Accessories
Devices

Fig.

Starting Relay

a2

SC10MLX
117U6011

Cover

103N2008

Starting capacitor 80 F

117U5019

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CJ.54.L1.02

CK.54.B6.02

August 2002

69

SC12CLX.2
LBP Compressor
R404A/R507
220-240V 50/60Hz
Data Sheet
General
SC12CLX.2

Code number

104L2697

104L

SC12CLX.2
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-40 to -10

Yellow background

2697

DANFOSS COMPRESSORS

8469

Compressor

198 - 254 /50


198 - 254 /60

SC12CLX.2
230V-60Hz
1PH

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

8469-2

Motor type

THERMALLY
PROTECTED

Approval mark
S
O
F1

Design
Displacement

cm3

Oil quantity

cm3

550

1300

1510

kg

13.7

Maximum refrigerant charge


Free gas vol. in compressor

12.87

cm

Weight without electrical equipment

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
178
170

16

19
9.7

LRA (rated after 4 sec. UL984) HST

watt

495

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

UL984/CSA-C22.2

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
A

219

213

B1

193

B2

110

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

B2

255

80
55

63

151

Compressors on a pallet

B A

B1

37

37

107

September 2002

70

CJ.54.C1.02

CK.54.B6.02

107
115

55
63

mm

Height

8258

September 2002

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz

-40

-35

240

380

watt
-30

-25
540
645

-23.3

-20

-15

1146

Capacity (ASHRAE)
Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz

-10
c

watt

-40

-35

169

327

-30

-25
626
748

-23.3

-20

-15

-10
1397

b
8222

Power consumption
Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz

watt

-40

-35

344

425

-30

-25
487
570

-23.3

-20

-15

-10

Current consumption
Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz

a2

772

-40

-35

2.40

2.70

-30

-25
3.32
3.27

-23.3

-20

-15

-10
c

4.16

11

10

COP (EN 12900/CECOMAF)


Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz

-40

-35

0.70

0.89

-40

-35

0.80

1.03

W/W
-30

-25
1.11
1.13

-23.3

-25
1.28
1.31

-23.3

-20

-15

12

13
14

1.48

COP (ASHRAE)
Evap. temp in C
SC12CLX.2, 50Hz
SC12CLX.2, 60Hz

-10

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V
preliminary data

-30

EN 12900/CECOMAF
45C
32C
45C

-20

-15

-10
1.73

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

Starting Relay

a2

SC12CLX.2
117U6019

Cover

103N2008

Starting capacitor 80 F

117U5019

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

118-1917
118-1918
118-1919

CJ.54.C1.02

September 2002

CK.54.B6.02

September 2002

71

SC12MLX
MBP Compressor
R404A/R507
220-240V 50Hz & 208-230V 60Hz
Data Sheet
General
SC12MLX

Code number

104L2606

104L

SC12MLX
Application

R404A
R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range

C (F)

Voltage range

V/Hz

MBP

Barcode on
white background

-23.3 to 7.2 (-10 to 45)

Yellow background

2606

8365-3

Compressor

DANFOSS COMPRESSORS

187 - 254 /50

187 - 254 /60

SC12MLX

CSIR
C (F)

208-230V-60Hz

43 (110)

Comp. cooling at ambient temp. 32C (90F)

F2

38C (100F)

F2

43C (110F)

F2

1PH
THERMALLY
PROTECTED

Approval mark
S
O
F1

Design
cm3

Oil quantity

cm

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

12.87

1300

cm3

1410

kg

13.9

Motor
Motor size

watt

590

LRA (rated after 4 sec. UL984) HST

23.4

Cut-in current HST

23.4

Resistance, main and start winding (25C)


Approvals

F2

600

3.4/14.4

204
178
170

16

19
9.7

127
101.6
35

Displacement

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

70
150

Max. ambient temperature

8465-4

Motor type

127
165
186

218

EN 60335-2-34, UL984/CSA-C22.2

E
Dimensions

B1

193

B2

110

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.5 0.09

Discharge connector

location/I.D. mm

6.5 0.09

pcs.

80

B2

265

55

Compressors on a pallet

B A

B1

37

37

107

August 2002

72

CJ.54.M1.02

CK.54.B6.02

107
115

63

219
213

59.5
55

A
B

mm

151

Height

8432-2

September 2002

Conditions: ASHRAE MBP 60Hz


Evap. temp inF
Evap. temp inC
Capacity in Btu/h
Power cons. in W
Current cons. in A
EER in Btu/Wh

-10
-23.3
1885
551
3.39
3.42

0
-17.8
2554
646
3.70
3.95

10
-12.2
3335
738
4.06
4.52

14
-10.0
3684
775
4.21
4.75

20
-6.7
4250
831
4.46
5.12

30
-1.1
5320
928
4.92
5.73

40
4.4
6564
1035
5.42
6.34

45
7.2
7259
1092
5.69
6.64

10
-12.2
2915
641
4.15
4.55

14
-10.0
3213
667
4.25
4.82

20
-6.7
3700
705
4.40
5.25

30
-1.1
4622
768
4.67
6.02

40
4.4
5701
829
4.96
6.87

45
7.2
6304
860
5.11
7.33

-5
23
1465
801
4.37
1.83

0
32
1770
882
4.73
2.01

5
41
2118
975
5.14
2.17

-5
23
1272
667
4.27
1.91

0
32
1542
714
4.47
2.16

5
41
1852
762
4.69
2.43

Conditions: ASHRAE MBP 50Hz


Evap. temp inF
Evap. temp inC
Capacity in Btu/h
Power cons. in W
Current cons. in A
EER in Btu/Wh

-10
-23.3
1694
507
3.72
3.34

0
-17.8
2252
575
3.92
3.91

-23.3
-10
659
561
3.38
1.18

-20
-4
773
601
3.52
1.29

-15
5
970
664
3.76
1.46

-10
14
1199
729
4.05
1.64

-6.7
20
1370
776
4.26
1.77

8468

a2
b
a2
Start winding

Conditions: EN 12900/CECOMAF (no subcooling) 60Hz


Evap. temp inC
Evap. temp inF
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W

c
Main winding

Thermostat
Winding protector

Conditions: EN 12900/CECOMAF (no subcooling) 50Hz


Evap. temp inC
Evap. temp inF
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W

-23.3
-10
572
493
3.67
1.16

-20
-4
669
525
3.76
1.27

-15
5
838
572
3.91
1.46

Test conditions
EN 12900/CECOMAF
Condensing temperature 45C
Return gas temperature
32C
Liquid temperature
45C
50Hz: Fan cooling F2 , 220V
60Hz: Fan cooling F2 , 230V

-10
14
1038
620
4.08
1.68

-6.7
20
1188
651
4.20
1.83

ASHRAE
54.4C
35.0C
46.1C

Accessories
Devices

Fig.

SC12MLX

Starting Relay

a2

117-7426

Starting Relay (alternative)

a2

117-7422

Cover

1117U1021

Starting capacitor 80 F

117U5019

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CJ.54.M1.02

CK.54.B6.02

August 2002

73

TF4CLX
LBP/MBP Compressor
R404A/R507
115-127V 60Hz
Data Sheet (Replaces CF.52.E1.22)
General
Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

102U

TF4CLX

TF4CLX

Connector-material

Application

Code number

R404A
R507

Lilac stripe

102U2102

2102

Barcode on
white background

DANFOSS COMPRESSORS

Green background

Application

LBP/MBP
F (C)

-49 to 45 (-45 to 7.2)

V/Hz

TF4CLX
115V-60Hz
1PH

95 - 135 /60

Motor type

CSIR
F (C)

THERMALLY
PROTECTED

110 (43)

Comp. cooling at
110F (43C)

F1

S
O
F1
F2

Design
3

17.5 (500)

fl.oz. (cm3)

57.3 (1690)

Free gas vol. in compressor housing

lbs. (kg)

17.9 (8.1)

Motor

4.02"(102)

watt

225

LRA (rated after 4 sec.UL984) HST

20.0

Cut-in current HST

20.0

Resistance, main and start winding (77F)

C or
D

8370

or

8.90"(226)
6.93"(176)

6.65 (169)

Suction connector

location/I.D. in. (mm) C 0.252-0.259 (6.50.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E 0.189-0.193 (4.9+0.10/-0)

4.13"(105)
4.21"(107)

0.75"(19)

6.50"(165)

0.63"(16)

0.14"(3.6)
2.76"(70)

6.81 (173)

4.13"(105)

A B

in. (mm) A

31.5
28

UL984/CSA-C22.2

Dimensions

D
C
E

2.6/3.8

Approvals

pcs.

3.78"(96)
4.61"(117)

30

Motor size

Compressors on a pallet

45

Weight without electrical equipment

(29)

9.5 (280)

oz. (g)

Maximum refrigerant charge

0.23 (3.86)

125

5.35"(136)

fl.oz. (cm3)

51 20

cu.in. (cm )

Oil quantity

6.18"(157)

Displacement

Approval mark

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

2.34"(59.5)
2.60" (66)

max. ambient temperature

1.14"

Max. ambient temperature

2.80"(71)

Voltage range

4.00"(101.6)

Evaporating temperature range

8404-2

Application

Height

8404

Compressor

6.70"(170)
7.01"(178)
8.03"(204)

September 2002

74

CF.52.E2.22

CK.54.B6.02

September 2002

Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
CECOMAF

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-49
-45
124
195
106
44

-40
-40
223
290
190
71

-30
-20
-34.4 -28.9
354
512
421 582
302
437
104
145

-13
-25
641
714
547
178

-10
0
10
-23.3 -17.8 -12.2
702
928 1197
776 1008 1282
599
791 1018
194
252
321

20
-6.7
1512
1603
1285
401

30
40
45
-1.1
4.4
7.2
1880 2306 2544
1973 2398 2632
1595 1953 2151
493
599
657

Power consumption (ASHRAE, EN12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
CECOMAF

-49
-45
97
106
97
103

-40
-40
117
121
117
120

-30
-20
-34.4 -28.9
139
160
138
155
139
160
138
156

-13
-25
176
169
176
169

-49
-45
2.01
2.05
2.01
2.03

-40
-40
2.07
2.08
2.07
2.08

-30
-20
-34.4 -28.9
2.16 2.29
2.16 2.27
2.16 2.29
2.15 2.27

-49
-45
1.27
1.83
1.09
0.43

-40
-40
1.90
2.39
1.62
0.59

-30
-20
-34.4 -28.9
2.55 3.19
3.06 3.75
2.18 2.72
0.76 0.93

EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
CECOMAF
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz

-13
-25
2.41
2.36
2.41
2.36

a2

watt

-10
0
10
-23.3 -17.8 -12.2
184
209
239
175
198
226
184
209
239
176
199
227

20
-6.7
273
259
273
260

30
-1.1
313
299
313
300

40
4.4
360
347
360
348

Current consumption (ASHRAE, EN12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
CECOMAF

45
7.2
387
374
387
375

8226

dc
b
a2
c

-10
0
10
-23.3 -17.8 -12.2
2.46 2.66 2.90
2.41 2.59 2.80
2.46 2.66 2.90
2.41 2.59 2.81

20
-6.7
3.17
3.05
3.17
3.06

30
-1.1
3.47
3.33
3.47
3.35

40
4.4
3.81
3.64
3.81
3.67

45
7.2
3.99
3.82
3.99
3.84

10
12

Main winding

11
13

Start winding
Thermostat

14

Motor protector

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-13
-25
3.63
4.23
3.10
1.05

-10
0
10
-23.3 -17.8 -12.2
3.82 4.44 5.02
4.43 5.09 5.68
3.26 3.78 4.27
1.10 1.26 1.41

20
-6.7
5.54
6.19
4.71
1.54

30
-1.1
6.01
6.60
5.10
1.64

40
4.4
6.41
6.91
5.42
1.72

45
7.2
6.58
7.04
5.56
1.75

ASHRAE LBP ASHRAE LBP* ASHRAE MBP


EN 12900
130F (54.4C) 110F (43.3C) 130F (54.4C) 45C (113F)
90F (32C)
90F (32C)
95F (35C)
32C (90F)
90F (32C)
90F (32C)
95F (35C)
32C (90F)
90F (32C)
90F (32C)
115F (46C) 45C (113F)
Fan F1
Fan F1
Fan F1
Fan F1
115/60
115/60
115/60
115/60

Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
preliminary data

120 (49)
135 (58)

Accessories
Devices
Starting relay (Klixon incl.)
Klixon

Fig.
a2

TF4CLX
117U4148
MRP36EN-6

Starting capacitor 280 F

Cover

117U1021

Cord relief

117U0349

Cord relief for capacitor

dc

117U0349

Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

September 2002

in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)

117U5025

118-1945
118-1948
118-1944

CF.52.E2.22

CK.54.B6.02

September 2002

75

TFS4.5CLX
LBP Compressor
R404A/R507
115-127V 60Hz
Data Sheet (Replaces CF.52.D1.22)
General
TFS4.5CLX

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

Application

102U

TFS4.5CLX

Code number
Lilac stripe

R404A
SUCTION R507
CONNECTOR

102U2103

2103

Barcode on
white background

DANFOSS COMPRESSORS

Green background

Application

LBP
F (C)

-49 to 20 (-45 to -6.7)

V/Hz

TFS4CLX
115V-60Hz
1PH

103 - 135 /60

Motor type

CSIR
F (C)

THERMALLY
PROTECTED

110 (43)

Comp. cooling at
110F (43C)

F1

S
O
F1
F2

Design
3

14.0 (400)

fl.oz. (cm3)

57.3 (1690)

Free gas vol. in compressor housing

lbs. (kg)

17.9 (8.1)

Motor

4.02"(102)

watt

225

LRA (rated after 4 sec.UL984) HST

20.0

Cut-in current HST

20.0

Resistance, main and start winding (77F)

8246

8.90"(226)
6.93"(176)

in. (mm) A

6.81 (173)

6.65 (169)

Suction connector

location/I.D. in. (mm) C 0.252-0.259 (6.50.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E 0.189-0.193 (4.9+0.10/-0)

4.13"(105)
4.21"(107)
0.75"(19)

6.50"(165)

0.63"(16)

0.14"(3.6)

2.76"(70)

A B

4.13"(105)

UL984/CSA-C22.2

Dimensions

31.5
28

2.6/3.8

Approvals

pcs.

3.78"(96)
4.61"(117)

30

Motor size

Compressors on a pallet

45

Weight without electrical equipment

(29)

9.5 (280)

oz. (g)

Maximum refrigerant charge

0.29 (4.63)

125

5.35"(136)

fl.oz. (cm3)

51 20

cu.in. (cm )

Oil quantity

6.18"(157)

Displacement

Approval mark

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

2.34"(59.5)
2.60" (66)

max. ambient temperature

1.14"

Max. ambient temperature

2.80"(71)

Voltage range

4.00"(101.6)

Evaporating temperature range

8405-2

Application

Height

8405

Compressor

6.70"(170)
7.01"(178)
8.03"(204)

September 2002

76

CF.52.D2.22

CK.54.B6.02

September 2002

Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
CECOMAF

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-49
-45
210
289
67

-40
-40
332
407
100

-30
-34.4
494
569
141

-20
-28.9
690
769
192

-13
-25
851
933
233

-10
-23.3
926
1010
252

0
-17.8
1207
1298
325

10
-12.2
1539
1637
410

20
-6.7
1930
2034
509

Power consumption (ASHRAE, EN12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
CECOMAF

-49
-45
100
113
109

-40
-40
130
135
134

-30
-34.4
161
160
160

-20
-28.9
194
186
187

-13
-25
217
206
207

-10
-23.3
228
215
217

0
-17.8
266
250
251

10
-12.2
310
291
292

Current consumption (ASHRAE, EN12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
CECOMAF

-49
-45
2.18
2.23
2.21

-40
-40
2.26
2.29
2.28

-49
-45
2.10
2.55
0.62

-40
-40
2.56
3.01
0.75

EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
CECOMAF
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz

-30
-34.4
2.40
2.39
2.39

-20
-28.9
2.60
2.55
2.55

-13
-25
2.76
2.70
2.70

-10
-23.3
2.84
2.76
2.77

-20
-28.9
3.56
4.14
1.03

-13
-25
3.91
4.53
1.13

-10
-23.3
4.06
4.69
1.17

a2

20
-6.7
360
340
342

8226

dc

A
0
-17.8
3.14
3.03
3.04

10
-12.2
3.48
3.34
3.35

20
-6.7
3.88
3.70
3.72

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-30
-34.4
3.06
3.56
0.89

watt

0
-17.8
4.53
5.20
1.29

10
-12.2
4.97
5.63
1.40

20
-6.7
5.36
5.98
1.49

b
a2
c
10
12

Main winding

11
13

Start winding
Thermostat

14

Motor protector

ASHRAE LBP ASHRAE LBP*


EN 12900
130F (54.4C) 110F (43.3C) 45C (113F)
90F (32C)
90F (32C)
32C (90F)
90F (32C)
90F (32C)
32C (90F)
90F (32C)
90F (32C)
45C (113F)
Fan F1
Fan F1
Fan F1
115/60
115/60
115/60

Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak

120 (49)
135 (58)

Accessories
Devices
Starting relay (Klixon incl.)
Klixon

Fig.
a2

TFS4.5CLX
117U4148
MRP36EN-6

Starting capacitor 280 F

Cover

117U1021

Cord relief

117U0349

Cord relief for capacitor

dc

117U0349

Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)

118-1945
118-1948
118-1944

September 2002

117U5025

CF.52.D2.22

CK.54.B6.02

September 2002

77

NF5.5CLX
LBP/MBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
NF5.5CLX

Connector-material

Sealing

Code number

Copper-plated steel

Aluminium caps

105F1621

Copper-plated steel

Rubber plugs

105F1622

Copper

Rubber plugs

Application

105F

NF5.5CLX
R404A
SUCTION R507
CONNECTOR

Lilac stripe

1621

Barcode on
white background

DANFOSS COMPRESSORS

Green background

Application

8406-3

Compressor

LBP/MBP

Evaporating temperature range

NF5.5CLX
115V-60Hz
1PH

-49 to 45 (-45 to 7.2)

F (C)

Voltage range

V/Hz

LBP: 95 - 135 /60


MBP: 103 - 135 /60

Motor type

CSIR

Max. ambient temperature

F (C)

110 (43)

Comp. cooling at
max. ambient temperature

110F (43C)

F2

THERMALLY

S
O
F1
F2

PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

8406-4

Application

10.8 (320)

oz. (g)

14.0 (400)

fl.oz. (cm3)

76.9 (2280)

lbs. (kg)

22.2 (10.0)

Maximum refrigerant charge


Free gas vol. in compressor housing
Weight without electrical equipment

0.37 (6.13)

4.45"(113)

310

30.0
30.0

1.9/6.6

Approvals

UL984/CSA-C22.2

A B

15

Resistance, main and start winding (77F)

9.92"(252)
8.03"(204)
6.70"(170)

Dimensions
B

8.00 (203)

location/I.D. in. (mm) C

0.320-0.327 (8.20.09)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.50.09)

Compressors on a pallet

pcs.

8367

7.76 (197)

Suction connector

1.38"(35)

in. (mm) A

5.20"(132)
4.00"(101.6)
2.76"(70)

Height

35

Cut-in current HST

4.04"(102.5)

watt

E
C

25

LRA (rated after 4 sec.UL984) HST

4.69"(119)
5.00"(127)

3.68"(93.5)

Motor size

47

8.10"(205)

Motor

27

51

(54)

fl.oz. (cm3)

3.01"(78)

Oil quantity

2.97"(75.5)

cu.in. (cm3)

2.13"

Displacement

6.54"(166)
2.83"(72)
2.34" (59.5)

Design

0.75"(19)
0.63"(16)
0.38"(9.7)

80
6.50"(165)
7.32"(186)

September 2002

78

CF.53.G1.22

CK.54.B6.02

September 2002

Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-49
-45
304
399
260
97

-40
-40
463
566
396
140

-30
-20
-34.4 -28.9
675
933
789 1057
577
797
196
264

-13
-10
0
10
20
-25 -23.3 -17.8 -12.2 -6.7
1145 1245 1620 2066 2593
1276 1378 1759 2206 2728
977 1062 1380 1758 2204
319
345
441 554
685

30
40
-1.1
4.4
3211 3931
3331 4025
2724 3328
836 1010

Power consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

-49
-45
142
155
142
153

-40
-40
179
185
179
185

-30
-20
-34.4 -28.9
218
257
219
253
218
257
219
254

-13
-25
285
277
285
279

-49
-45
3.32
3.35
3.32
3.35

-40
-40
3.42
3.43
3.42
3.43

-30
-20
-34.4 -28.9
3.57 3.75
3.54 3.69
3.57 3.75
3.55 3.70

-49
-45
2.13
2.58
1.28
0.64

-40
-40
2.59
3.05
2.22
0.76

-30
-20
-34.4 -28.9
3.10 3.63
3.60 4.18
2.65 3.10
0.89 1.04

EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz

-13
-25
3.90
3.82
3.90
3.83

c
a2

watt

-10
0
10
-23.3 -17.8 -12.2
297
338
382
288
324
362
297
338
382
290
327
366

20
-6.7
428
404
428
408

30
-1.1
477
449
477
454

40
4.4
530
498
530
504

Current consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

45
7.2
4333
4408
3663
1106

8226

45
7.2
559
524
559
530

dc
b
a2
c

-10
0
10
-23.3 -17.8 -12.2
3.96 4.21 4.49
3.88 4.09 4.34
3.96 4.21 4.49
3.89 4.11 4.37

20
-6.7
4.81
4.63
4.81
4.65

30
-1.1
5.16
4.94
5.16
4.98

40
4.4
5.54
5.29
5.54
5.33

45
7.2
5.74
5.48
5.74
5.52

10
12

Start winding

11
13

Thermostat

Main winding

14

(pos.1)

Motor protector

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-13
-25
4.02
4.60
3.43
1.14

-10
0
10
-23.3 -17.8 -12.2
4.19 4.79 5.41
4.79 5.43 6.09
3.57 4.08 4.61
1.19 1.35 1.51

ASHRAE LBP ASHRAE LBP* ASHRAE MBP


130F (54.4C) 110F (43.3C) 130F (54.4C)
90F (32C)
90F (32C)
95F (35C)
90F (32C)
90F (32C)
95F (35C
90F (32C)
90F (32C)
115F (46C)
Fan F2
Fan F2
Fan F2
115/60
115/60
115/60

20
-6.7
6.06
6.76
5.15
1.68

30
-1.1
6.73
7.43
5.71
1.84

40
4.4
7.41
8.08
6.27
2.01

45
7.2
7.75
8.40
6.55
2.08

8408

EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60

a2

b
a2
7

Accessories

L
2

Devices

Fig.

NF5.5CLX

Starting relay (Klixon incl.)

a2

117U4061
MRP30AEN-6

Klixon
Starting capacitor 280 F

117U5025

b
d
dc
(pos.1)

117U1021
117U0349
117U0349

Cover (alternative) with terminal board

b
(pos.2)

117U1024

Mounting accessories (105G1622)


Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

in.(mm)
0.63 (16)
0.75 (19)
0.63 (16)

Mounting accessories (105G1621)


Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

in.(mm)
0.63 (16)
0.63 (16)
0.63 (16)

September 2002

Main winding

11

10
4

13

12

c
Start winding

5
14

M
6

Cover (standard)
Cord relief
Cord relief for capacitor

(pos.2)

Motor protector

Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak

120 (49)
135 (58)

118-1945
118-1948
118-1944
118-1917
118-1918
118-1919

CF.53.G1.22

CK.54.B6.02

September 2002

79

NF7CLX
LBP/MBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
NF7CLX

Connector-material

Sealing

Code number

Copper-plated steel

Aluminium caps

105F1721

Copper-plated steel

Rubber plugs

105F1722

Copper

Rubber plugs

Application

105F

NF7CLX
R404A
SUCTION R507
CONNECTOR

Lilac stripe

1722

Barcode on
white background

DANFOSS COMPRESSORS

Green background

Application

8406

Compressor

LBP/MBP

Evaporating temperature range

NF7CLX
115V-60Hz
1PH

-49 to 45 (-45 to 7.2)

F (C)

Voltage range

V/Hz

LBP: 95 - 135 /60


MBP: 108 - 135 /60

Motor type

CSIR

Max. ambient temperature

F (C)

110 (43)

Comp. cooling at
max. ambient temperature

110F (43C)

F2

THERMALLY

S
O
F1
F2

PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

8406-2

Application

10.8 (320)

oz. (g)

14.0 (400)

fl.oz. (cm3)

76.9 (2280)

lbs. (kg)

22.2 (10.0)

Maximum refrigerant charge


Free gas vol. in compressor housing
Weight without electrical equipment

0.68 (7.27)

4.45"(113)

330

28.0
28.0

1.7/5.4

Approvals

UL984/CSA-C22.2

A B

15

Resistance, main and start winding (77F)

9.92"(252)
8.03"(204)
6.70"(170)

Dimensions
B

8.00 (203)

location/I.D. in. (mm) C

0.320-0.327 (8.20.09)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.50.09)

Compressors on a pallet

pcs.

8367

7.76 (197)

Suction connector

1.38"(35)

in. (mm) A

5.20"(132)
4.00"(101.6)
2.76"(70)

Height

35

Cut-in current HST

4.04"(102.5)

watt

E
C

25

LRA (rated after 4 sec.UL984) HST

4.69"(119)
5.00"(127)

3.68"(93.5)

Motor size

47

8.10"(205)

Motor

27

51

(54)

fl.oz. (cm3)

3.01"(78)

Oil quantity

2.97"(75.5)

cu.in. (cm3)

2.13"

Displacement

6.54"(166)
2.83"(72)
2.34" (59.5)

Design

0.75"(19)
0.63"(16)
0.38"(9.7)

80
6.50"(165)
7.32"(186)

September 2002

80

CF.53.H1.22

CK.54.B6.02

September 2002

Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-49
-45
327
458
279
111

-40
-40
531
674
454
166

-30
-20
-34.4 -28.9
805 1137
961 1306
688
971
238
326

-13
-10
0
-25 -23.3 -17.8
1410 1539 2021
1588 1719 2209
1203 1312 1722
397
430
553

10
20
-12.2 -6.7
2595 3274
2785 3457
2209 2782
699
868

30
40
45
-1.1
4.4
7.2
4069 4996 5513
4234 5127 5620
3452 4229 4661
1063 1286 1409

Power consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

-49
-45
176
191
176
189

-40
-40
221
229
221
229

-30
-20
-34.4 -28.9
270
318
271 313
270
318
271 314

-13
-25
353
343
353
345

-49
-45
3.60
3.65
3.60
3.64

-40
-40
3.75
3.76
3.75
3.76

-30
-20
-34.4 -28.9
3.96 4.22
3.93 4.14
3.96 4.22
3.93 4.15

-49
-45
1.85
2.39
1.58
0.59

-40
-40
2.41
2.94
2.06
0.72

-30
-20
-34.4 -28.9
2.98 3.57
3.54 4.17
2.55 3.05
0.88 1.04

EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz

-13
-25
4.43
4.32
4.43
4.33

a2

watt

-10
0
10
-23.3 -17.8 -12.2
368
419
472
356
401 448
368
419
472
358
404
452

20
-6.7
529
499
529
504

30
-1.1
590
555
590
561

40
4.4
656
616
656
623

Current consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

8226

45
7.2
691
649
691
656

dc
b
a2
c

-10
0
10
-23.3 -17.8 -12.2
4.53 4.88 5.29
4.40 4.71 5.07
4.53 4.88 5.29
4.42 4.74 5.10

20
-6.7
5.74
5.47
5.74
5.51

30
-1.1
6.24
5.93
6.24
5.97

40
4.4
6.78
6.43
6.78
6.48

45
7.2
7.07
6.70
7.07
6.76

10
12

Start winding

11
13

Thermostat

Main winding

14

(pos.1)

Motor protector

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-13
-25
4.00
4.63
3.41
1.15

-10
0
10
-23.3 -17.8 -12.2
4.18 4.83 5.50
4.83 5.52 6.22
3.57 4.11 4.68
1.20 1.37 1.54

ASHRAE LBP ASHRAE LBP* ASHRAE MBP


130F (54.4C) 110F (43.3C) 130F (54.4C)
90F (32C)
90F (32C)
95F (35C)
90F (32C)
90F (32C)
95F (35C
90F (32C)
90F (32C)
115F (46C)
Fan F2
Fan F2
Fan F2
115/60
115/60
115/60

20
-6.7
6.19
6.92
5.26
1.72

30
-1.1
6.90
7.63
5.85
1.89

40
4.4
7.61
8.32
6.45
2.07

45
7.2
7.97
8.66
6.74
2.15

8408

EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60

a2

b
a2
7

Accessories

L
2

Devices

Fig.

NF7CLX

Starting relay (Klixon incl.)

a2

117U4129

Main winding

11

10

N
4

13

12

c
Start winding

MRT22AFZ-6

Klixon
Starting capacitor 320 F

117U5022

Cover (standard)
Cord relief
Cord relief for capacitor

b
d
dc
(pos.1)

117U1021
117U0349
117U0349

Cover (alternative) with terminal board

b
(pos.2)

117U1024

Mounting accessories (105G1722)


Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

in.(mm)
0.63 (16)
0.75 (19)
0.63 (16)

Mounting accessories (105G1721)


Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

in.(mm)
0.63 (16)
0.63 (16)
0.63 (16)

September 2002

14

(pos.2)

Motor protector

Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak

120 (49)
135 (58)

118-1945
118-1948
118-1944
118-1917
118-1918
118-1919

CF.53.H1.22

CK.54.B6.02

September 2002

81

SC10CL
LBP/MBP Compressor
R404A/R507
115V 60Hz
Data Sheet (Replaces CF.54.Q2.22)
General
Compressor

104L

SC10CL

SC10CL

Codenumber (CU-plated steel connectors)

Application

104L1503

R404A
R507

Application
Evaporating temperature range

F (C)

Voltage range

V/Hz

LBP/MBP

Barcode on
white background

-40 to 45 (-40 to 7.2)

Green background

1503

DANFOSS COMPRESSORS

103 - 127 /60

CSIR

SC10CL
115V-60Hz
1PH

110 (43)

Comp. cooling at
110F (43C)

F2

THERMALLY

S
O
F1

Design
Displacement

cu.in. (cm3)

0.63 (10.29)

Oil quantity

fl.oz. (cm3)

18.6 (550)

Maximum refrigerant charge

oz. (g)

45.8 (1300)

Free gas vol. in compressor housing fl.oz. (cm3)

51.1 (1510)

Weight without electrical equipment

27.7 (12.6)

lbs. (kg)

Motor
Motor size

watt

540

LRA (rated after 4 sec.UL984) HST

41.9

Cut-in current HST

41.9

Resistance, main and start winding (77F)

4.21"(107)

4.21"(107)
4.53"(115)

E
B A

B1

8.00 (203)

B1

7.20 (183)

B2

3.93 (100)

location/I.D. in. (mm) C

0.320-0.327 (8.20.09)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.50.09)

pcs.

80

0.63"(16)

10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)

5"(127)
6.50"(165)
7.32"(186)

82

CF.54.Q3.22

CK.54.B6.02

0.75"(19)
0.38"(9.7)

2.76"(70)
5.91"(150)

B2

0.12"(3)

8.23 (209)

5"(127)
4"(101.6)
1.38"(35)

in. (mm) A

Suction connector

September 2002

8.58"(218)

UL984/CSA-C22.2

Dimensions

Compressors on a pallet

37

37

1.0/4.3

Approvals

Height

F2

PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

5.94"(151)
2.17"(55)

max. ambient temperature

8323-2

F (C)

2.48"(63)

Max. ambient temperature

2.48"(63)
2.17"(55)

Motor type

8323

Lilac stripe

Application

8324

September 2002

Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-40
-40
147
499
126
113

-30
-34.4
624
926
533
223

-20
-28.9
1154
1422
986
349

-13
-25
1568
1818
1338
450

-10
-23.3
1758
2001
1500
497

0
-17.8
2453
2681
2091
668

10
-12.2
3261
3477
2775
869

20
-6.7
4200
4405
3570
1102

30
-1.1
5293
5483
4491
1372

40
4.4
6563
6727
5556
1682

41
5
6701
6861
5671
1716

10
-12.2
649
608
649
616

20
-6.7
719
664
719
674

30
-1.1
785
720
785
732

40
4.4
850
778
850
790

41
5
856
784
856
796

45
7.2
882
808
882
821

10
-12.2
7.37
7.08
7.37
7.13

20
-6.7
7.91
7.50
7.91
7.57

30
-1.1
8.44
7.91
8.44
8.00

40
4.4
8.95
8.31
8.95
8.41

41
5
9.00
8.34
9.00
8.45

45
7.2
9.21
8.50
9.21
8.61

Power consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

-40
-40
162
240
162
230

-30
-34.4
285
332
285
327

-20
-28.9
393
413
393
412

-13
-25
461
464
461
465

-10
-23.3
488
484
488
487

watt

0
-17.8
573
548
573
554

Current consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

-40
-40
4.52
4.83
4.52
4.79

-30
-34.4
5.11
5.30
5.11
5.28

-20
-28.9
5.69
5.77
5.69
5.76

-13
-25
6.09
6.08
6.09
6.09

-10
-23.3
6.26
6.22
6.26
6.23

-40
-40
0.91
2.08
0.77
0.49

-30
-34.4
2.19
2.79
1.87
0.68

-20
-28.9
2.94
3.44
2.51
0.85

-13
-25
3.40
3.92
2.90
0.97

-10
-23.3
3.60
4.13
3.07
1.02

EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
ASHRAE MBP
EN 12900

45
7.2
7272
7417
6148
1854

0
-17.8
6.82
6.66
6.82
6.69

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


0
-17.8
4.28
4.89
3.65
1.21

10
-12.2
5.02
5.72
4.27
1.41

20
-6.7
5.84
6.63
4.96
1.63

ASHRAE LBP ASHRAE LBP* ASHRAE MBP


EN 12900
Test conditions
Condensing temp. 130F (54.4C) 110F (43.3C) 130F (54.4C) 45C (113F)
Suction gas temp.
90F (32C)
90F (32C)
95F (35C)
32C (90F)
Ambient temp.
90F (32C)
90F (32C)
95F (35C
32C (90F)
Liquid temp.
90F (32C)
90F (32C)
115F (46C) 45C (113F)
Cooling
Fan F2
Fan F2
Fan F2
Fan F2
V/Hz
115/60
115/60
115/60
115/60
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak

30
-1.1
6.74
7.61
5.72
1.87

40
4.4
7.73
8.65
6.54
2.13

41
5
7.83
8.75
6.63
2.15

45
7.2
8.25
9.18
6.97
2.26

b
8222

a2

120 (49)
135 (58)

Accessories
Devices

Fig.

SC10CL

Starting relay

a2

117U6020

Cover

103N2008

Starting capacitor 240 F

117U5023

Cord relief

103N1004

c
11

10

12

13
14

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.Q3.22

CK.54.B6.02

Start winding
Main winding
Winding protector

September 2002

83

SC12CL
LBP Compressor
R404A/R507
115V 60Hz
Data Sheet (Replaces CF.54.U1.22)
General
Compressor

104L

SC12CL

SC12CL

Codenumber (CU-plated steel connectors)

Application

104L1603

R404A
R507

Application
Evaporating temperature range

F (C)

Voltage range

V/Hz

LBP

Barcode on
white background

-40 to 10 (-40 to -12.2)

Green background

1603

DANFOSS COMPRESSORS

103 - 127 /60

CSIR

SC12CL
115V-60Hz
1PH

110 (43)

Comp. cooling at
110F (43C)

F2

THERMALLY

S
O
F1

Design
Displacement

cu.in. (cm3)

0.78 (12.87)

Oil quantity

fl.oz. (cm3)

18.6 (550)

Maximum refrigerant charge

oz. (g)

45.8 (1300)

Free gas vol. in compressor housing fl.oz. (cm3)

51.1 (1510)

Weight without electrical equipment

27.7 (12.6)

lbs. (kg)

Motor
Motor size

watt

540

LRA (rated after 4 sec.UL984) HST

41.9

Cut-in current HST

41.9

Resistance, main and start winding (77F)

4.21"(107)
4.53"(115)

E
B A

8.00 (203)

B1

7.20 (183)

B2

3.93 (100)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.50.09)

pcs.

80

0.63"(16)

10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)

5"(127)
6.50"(165)
7.32"(186)

84

CF.54.U2.22

CK.54.B6.02

0.75"(19)
0.38"(9.7)

2.76"(70)
5.91"(150)

B2

0.12"(3)

8.23 (209)

5"(127)
4"(101.6)
1.38"(35)

in. (mm) A

0.320-0.327 (8.20.09)

September 2002

8.58"(218)

B1

location/I.D. in. (mm) C

Compressors on a pallet

4.21"(107)

UL984/CSA-C22.2

Dimensions

Suction connector

37

37

1.0/4.3

Approvals

Height

F2

PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

5.94"(151)
2.17"(55)

max. ambient temperature

8323-4

F (C)

2.48"(63)

Max. ambient temperature

2.48"(63)
2.17"(55)

Motor type

8323-3

Lilac stripe

Application

8324

September 2002

Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-40
-40
143
648
146

-30
-34.4
842
1229
297

-20
-28.9
1577
1871
463

-13
-25
2127
2366
590

-10
-23.3
2374
2592
648

0
-17.8
3255
3414
857

10
-12.2
4246
4356
1095

0
-17.8
739
720
723

10
-12.2
848
822
826

Power consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900

-40
-40
212
322
308

-30
-34.4
374
436
429

-20
-28.9
510
535
533

-13
-25
595
599
600

watt

-10
-23.3
629
627
628

Current consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900

-40
-40
4.92
5.32
5.26

EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900

-30
-34.4
5.44
5.69
5.64

-20
-28.9
6.08
6.17
6.15

-13
-25
6.60
6.59
6.58

b
8222

a2
d

-10
-23.3
6.84
6.78
6.79

0
-17.8
7.73
7.52
7.55

10
-12.2
8.74
8.38
8.43

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-40
-40
0.68
2.01
0.48

-30
-34.4
2.25
2.82
0.69

-20
-28.9
3.09
3.50
0.87

-13
-25
3.58
3.95
0.98

-10
-23.3
3.77
4.14
1.03

0
-17.8
4.40
4.74
1.18

10
-12.2
5.01
5.30
1.33

11

10

12

13
14

Start winding
Main winding
Winding protector

Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz

ASHRAE LBP
130F (54.4C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60

Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak

ASHRAE LBP*
110F (43.3C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60

EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60

120 (49)
135 (58)

Accessories
Devices

Fig.

SC12CL

Starting relay

a2

117U6020

Cover

103N2008

Starting capacitor 240 F

117U5023

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.U2.22

CK.54.B6.02

September 2002

85

SC12CLX.2
LBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
Compressor

104L

SC12CLX.2

SC12CLX.2

Codenumber (CU-plated steel connectors)

Application

104L1696

R404A
R507

Application
Evaporating temperature range

F (C)

Voltage range

V/Hz

LBP

Barcode on
white background

-40 to 20 (-40 to -6.7)

Green background

1696

DANFOSS COMPRESSORS

103 - 127 /60

CSIR

SC12CLX.2
115V-60Hz
1PH

110 (43)

Comp. cooling at
110F (43C)

F2

THERMALLY

S
O
F1

Design
Displacement

cu.in. (cm3)

0.78 (12.87)

Oil quantity

fl.oz. (cm3)

18.6 (550)

Maximum refrigerant charge

oz. (g)

45.8 (1300)

Free gas vol. in compressor housing fl.oz. (cm3)

51.1 (1510)

Weight without electrical equipment

27.7 (12.6)

lbs. (kg)

Motor
Motor size

watt

540

LRA (rated after 4 sec.UL984) HST

41.9

Cut-in current HST

41.9

Resistance, main and start winding (77F)

4.21"(107)
4.53"(115)

E
B A

8.00 (203)

B1

7.20 (183)

B2

3.93 (100)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.50.09)

pcs.

80

0.63"(16)

10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)

5"(127)
6.50"(165)
7.32"(186)

86

CJ.54.N1.22

CK.54.B6.02

0.75"(19)
0.38"(9.7)

2.76"(70)
5.91"(150)

B2

0.12"(3)

8.23 (209)

5"(127)
4"(101.6)
1.38"(35)

in. (mm) A

0.320-0.327 (8.20.09)

September 2002

8.58"(218)

B1

location/I.D. in. (mm) C

Compressors on a pallet

4.21"(107)

UL984/CSA-C22.2

Dimensions

Suction connector

37

37

1.0/4.3

Approvals

Height

F2

PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

5.94"(151)
2.17"(55)

max. ambient temperature

8464-4

F (C)

2.48"(63)

Max. ambient temperature

2.48"(63)
2.17"(55)

Motor type

8464

Lilac stripe

Application

8324

September 2002

Capacity
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-40
-40

-30
-34.4

950
240

1500
380

-20
-28.9

-13
-25
2540
645

-10
-23.3
2550
2730
690

0
-17.8

10
-12.2

Power consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900

-40
-40

-30
-34.4

380
360

460
450

-20
-28.9

-13
-25

-10
-23.3
617
616
616

585
585

20
-6.7
5250
5350
1290

watt

0
-17.8

10
-12.2

20
-6.7
930

-40
-40

-30
-34.4

5.35
5.30

6.10
6.00

EER / COP
Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900

-20
-28.9

-13
-25
6.65
6.65

-10
-23.3
6.95
6.90
6.90

b
8222

a2

Current consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp inF
Evap. temp inC
ASHRAE LBP
ASHRAE LBP*
EN 12900

0
-17.8

10
-12.2

20
-6.7
9.50

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-40
-40

-30
-34.4

2.50
0.66

3.26
0.84

-20
-28.9

-13
-25
4.34
1.10

-10
-23.3
4.13
4.43
1.12

11

10

0
-17.8

10
-12.2

12

13
14

20
-6.7
5.64

Start winding
Main winding
Winding protector

Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz

ASHRAE LBP
130F (54.4C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60

Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
preliminary data

ASHRAE LBP*
110F (43.3C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60

EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60

120 (49)
135 (58)

Accessories
Devices

Fig.

SC12CLX.2

Starting relay

a2

117U6020

Cover

103N2008

Starting capacitor 240 F

117U5023

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CJ.54.N1.22

CK.54.B6.02

September 2002

87

SC12MLX
MBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
Compressor (CU-plated steel connectors)

SC12MLX

Codenumber

104L1606

104L

SC12MLX
Application

R404A
R507

Application
Evaporating temperature range

F (C)

Voltage range

V/Hz

MBP

Barcode on
white background

-10 to 45 (-23.3 to 7.2)

Green background

1606

DANFOSS COMPRESSORS

95 - 135 /60

CSIR
F (C)

SC12MLX
115V-60Hz
1PH

110 (43)

Comp. cooling at
110F (43C)

F2

Design
cu.in. (cm3)

0.78 (12.86)

fl.oz. (cm3)

Maximum refrigerant charge

45.5 (1300)

Free gas vol. in compressor housing fl.oz. (cm3)

49.4 (1460)

Weight without electrical equipment

30.2 (13.7)

lbs. (kg)

37

37

4.21"(107)

Motor

D
watt

755

LRA (rated after 4 sec.UL984) HST

53

Cut-in current HST

53

Resistance, main and start winding (77F)

4.21"(107)
4.53"(115)

E
B A

B1
B2

0.12"(3)

UL984/CSA-C22.2

8.62 (219)

8.39 (213)

B1

7.60 (193)

B2

4.33 (110)

Suction connector

location/I.D. in. (mm) C 0.320-0.327 (8.20.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E


pcs.

0.252-0.259 (6.50.09)

0.63"(16)

10.43"(265)
8.03"(204)
7.01"(178)
6.69"(170)

88

0.38"(9.7)

60
5"(127)
6.50"(165)
7.32"(186)

May 2002

0.75"(19)

2.76"(70)
5.91"(150)

in. (mm) A

5"(127)
4"(101.6)
1.38"(35)

Dimensions

Compressors on a pallet

8.58"(218)

0.7/2.9

Approvals

Height

Approval mark

20.3 (600)

oz. (g)

Motor size

THERMALLY
PROTECTED

2.48"(63)

Oil quantity

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temp.
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

2.34" (59.5)

Displacement

S
O
F1

5.94"(151)
2.17"(55)

max. ambient temperature

2.17"(55)

Max. ambient temperature

8459-4

Motor type

8459-7

Lilac stripe

Application

CJ.54.J1.22

CK.54.B6.02

8432

September 2002

Capacity
Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-10
-23.3
1987
667

0
-17.8
2640
864

10
-12.2
3435
1103

20
-6.7
4391
1388

30
-1.1
5527
1725

40
4.4
6865
2118

41
5
7011
2160

45
7.2
7616
2337

Power consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900

-10
-23.3
581
589

0
-17.8
676
662

10
-12.2
770
735

20
-6.7
865
811

30
-1.1
960
890

40
4.4
1058
973

41
5
1067
982

45
7.2
1107
1017

-10
-23.3
7.93
7.94

EER / COP
Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900

0
-17.8
8.50
8.38

10
-12.2
9.13
8.88

20
-6.7
9.83
9.44

30
-1.1
10.58
10.06

41
5
11.48
10.81

45
7.2
11.82
11.10

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-10
-23.3
3.42
1.13

Test conditions
Condensing temperature
Suction gas temperature
Ambient temperature
Liquid temperature
Cooling
V/Hz
Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak

0
-17.8
3.90
1.31

10
-12.2
4.46
1.50

20
-6.7
5.08
1.71

ASHRAE MBP
130F (54.4C)
95F (35C)
90F (32C)
115F (46C)
Fan F2
115/60

30
-1.1
5.76
1.94

8433

40
4.4
11.39
10.74

40
4.4
6.49
2.18

41
5
6.57
2.20

45
7.2
6.88
2.30

EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60

watt

Current consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900

a2
b
a2
Start winding

c
Main winding
R

Thermostat

Motor protector
M

120 (49)
135 (58)

Accessories
Devices

Fig.

Starting relay

a2

117-7441

Starting capacitor 410 F

117U5028

Cover

Protector

Protector holder

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)

SC12MLX

(117U1021)
parts of
compressor

(117U3212)
(117U0438)

118-1917
118-1918
118-1919

CJ.54.J1.22

CK.54.B6.02

May 2002

89

SC15CLX.2
LBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
Compressor (CU-plated steel connectors)

SC15CLX.2

Codenumber

104L

SC15CLX.2
Application

104L1853

R404A
R507

Application
Evaporating temperature range

F (C)

Voltage range

V/Hz

LBP

Barcode on
white background

-40 to 20 (-40 to -6.7)

Green background

1853

DANFOSS COMPRESSORS

103 - 127 /60

CSIR

110F (43C)

F2

Design
Displacement

cu.in. (cm3)

Oil quantity

fl.oz. (cm3)

18.6 (550)

oz. (g)

45.5 (1300)

Free gas vol. in compressor housing fl.oz. (cm3)

49.4 (1460)

Weight without electrical equipment

30.2 (13.7)

Maximum refrigerant charge

0.93 (15.28)

lbs. (kg)

Motor
Motor size

watt

755

LRA (rated after 4 sec.UL984) HST

53

Cut-in current HST

53

Resistance, main and start winding (77F)

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temp.
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

5.94"(151)
2.17"(55)

max. ambient temperature

4.21"(107)

E
B A

B1

8.62 (219)

8.39 (213)

B1

7.60 (193)

B2

4.33 (110)

Suction connector

location/I.D. in. (mm) C 0.387-0.385 (9.70.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E


pcs.

0.63"(16)

10.43"(265)
8.03"(204)
7.01"(178)
6.69"(170)

0.252-0.259 (6.50.09)
60

5"(127)
6.50"(165)
7.32"(186)

90

CJ.54.I1.22

CK.54.B6.02

0.75"(19)
0.38"(9.7)

2.76"(70)
5.91"(150)

Compressors on a pallet

B2

0.12"(3)

in. (mm) A

5"(127)
4"(101.6)
1.38"(35)

Height

August 2002

8.58"(218)

UL984/CSA-C22.2

Dimensions

Approval mark

4.21"(107)
4.53"(115)

0.7/2.9

Approvals

THERMALLY
PROTECTED

37

37

8464-2

SC15CLX.2
115V-60Hz
1PH

110 (43)

2.48"(63)

F (C)

Comp. cooling at

2.34" (59.5)

Max. ambient temperature

2.17"(55)

Motor type

8464

Lilac stripe

Application

8432

September 2002

Capacity
Evap. temp in F
Evap. temp in C
ASHRAE LBP
ASHRAE LBP*
EN 12900

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-40
-40
57
783
175

-30
-34.4
989
1605
387

-20
-28.9
1964
2473
611

-13
-25
2671
3106
773

-10
-23.3
2980
3384
845

0
-17.8
4037
4337
1088

10
-12.2
5134
5331
1342

20
-6.7
6270
6364
1604

0
-17.8
839
804
809

10
-12.2
944
890
898

20
-6.7
1046
983
991

10
-12.2
10.42
10.18
10.24

20
-6.7
11.23
10.87
10.95

Power consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp in F
Evap. temp in C
ASHRAE LBP
ASHRAE LBP*
EN 12900

-40
-40
231
356
341

-30
-34.4
428
499
491

-20
-28.9
589
616
614

-13
-25
686
687
688

-10
-23.3
724
715
717

-40
-40
6.70
7.03
7.00

EER / COP
Evap. temp in F
Evap. temp in C
ASHRAE LBP
ASHRAE LBP*
EN 12900
Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz

-30
-34.4
7.40
7.62
7.61

-20
-28.9
8.13
8.23
8.24

-13
-25
8.65
8.67
8.69

-10
-23.3
8.87
8.86
8.88

-30
-34.4
2.31
3.22
0.79

-20
-28.9
3.33
4.01
0.99

ASHRAE LBP
130F (54.4C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60

Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak

-13
-25
3.90
4.52
1.12

-10
-23.3
4.12
4.73
1.18

ASHRAE LBP*
110F (43.3C)
90F (32C)
90F (32C)
90F (32C)
Fan F2
115/60

8433

0
-17.8
4.81
5.40
1.34

10
-12.2
5.44
5.99
1.49

20
-6.7
6.00
6.48
1.62

a2
b
a2

0
-17.8
9.64
9.51
9.55

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-40
-40
0.25
2.20
0.51

watt

Current consumption (ASHRAE, EN 12900/CECOMAF)


Evap. temp in F
Evap. temp in C
ASHRAE LBP
ASHRAE LBP*
EN 12900

Start winding

c
Main winding
R

Thermostat

Motor protector
M

EN 12900
45C (113F)
32C (90F)
32C (90F)
45C (113F)
Fan F2
115/60

120 (49)
135 (58)

Accessories
Devices

Fig.

Starting relay

a2

117-7441

Starting capacitor 410 F

117U5028

Cover

Protector

Protector holder

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)

SC15CLX.2

(117U1021)
parts of
compressor

(117U3212)
(117U0438)

118-1917
118-1918
118-1919

CJ.54.I1.22

CK.54.B6.02

August 2002

91

SC15MLX
MBP Compressor
R404A/R507
115V 60Hz
Data Sheet
General
Compressor (CU-plated steel connectors)

SC15MLX

Codenumber

104L1805

104L

SC15MLX
Application

R404A
R507

Application
Evaporating temperature range

F (C)

Voltage range

V/Hz

MBP

Barcode on
white background

-10 to 45 (-23.3 to 7.2)

Green background

1805

DANFOSS COMPRESSORS

CSR: 95 - 135 /60

8459-5

Lilac stripe

Application

CSIR: 103 - 135 /60

SC15MLX
115V-60Hz
1PH

CSIR/CSR
F (C)

110 (43)

Comp. cooling at
110F (43C)

F2

S
O
F1
F2

Design
cu.in. (cm3)

20.3 (600)

oz. (g)

45.5 (1300)

Free gas vol. in compressor housing fl.oz. (cm3)

49.4 (1460)

Weight without electrical equipment

30.9 (14.0)

lbs. (kg)

37

37

Motor
Motor size

watt

965

LRA (rated after 4 sec.UL984) HST

64

Cut-in current HST

4.21"(107)

4.21"(107)
4.53"(115)

0.6/2.7

Approvals

8.58"(218)

64

Resistance, main and start winding (77F)

UL984/CSA-C22.2
B A

B1

8.62 (219)

8.39 (213)

B1

7.60 (193)

B2

4.33 (110)

Suction connector

location/I.D. in. (mm) C 0.387-0.385 (9.70.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

Compressors on a pallet

pcs.

0.252-0.259 (6.50.09)
60

B2

0.63"(16)

10.43"(265)
8.03"(204)
7.01"(178)
6.69"(170)

5"(127)
6.50"(165)
7.32"(186)

92

CJ.54.E1.22

CK.54.B6.02

0.75"(19)
0.38"(9.7)

2.76"(70)
5.91"(150)

in. (mm) A

0.12"(3)

Height

5"(127)
4"(101.6)
1.38"(35)

Dimensions

September 2002

2.48"(63)

Maximum refrigerant charge

Approval mark

0.93 (15.28)

fl.oz. (cm3)

Oil quantity

THERMALLY
PROTECTED

2.34" (59.5)

Displacement

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temp.
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

5.94"(151)
2.17"(55)

max. ambient temperature

2.17"(55)

Max. ambient temperature

8459-6

Motor type

8432

September 2002

Capacity
Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900

ASHRAE in Btu/h - EN 12900/CECOMAF in watt


-10
-23.3
2295
770

0
-17.8
3049
998

10
-12.2
3967
1274

20
-6.7
5070
1603

30
-1.1
6383
1992

40
4.4
7928
2446

41
5
8096
2495

45
7.2
8795
2698

Power consumption (ASHRAE, EN12900/CECOMAF)


Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900

-10
-23.3
719
729

0
-17.8
837
819

10
-12.2
954
910

20
-6.7
1070
1004

30
-1.1
1188
1102

40
4.4
1309
1205

41
5
1321
1216

-10
-23.3
9.88
9.88

0
-17.8
10.59
10.43

EER / COP
Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900

10
-12.2
11.37
11.05

20
-6.7
12.24
11.75

30
-1.1
13.17
12.52

40
4.4
14.19
13.37

41
5
14.29
13.46

Test conditions
Condensing temp.
Suction gas temp.
Ambient temp.
Liquid temp.
Cooling
V/Hz

0
-17.8
3.64
1.22

10
-12.2
4.16
1.40

ASHRAE MBP
130F (54.4C)
95F (35C)
90F (32C)
115F (46C)
Fan F2
115/60

20
-6.7
4.74
1.60

30
-1.1
5.37
1.81

40
4.4
6.06
2.03

41
5
6.13
2.05

8460

45
7.2
14.72
13.82

ASHRAE in Btu/Wh - EN 12900/CECOMAF in W/W


-10
-23.3
3.19
1.06

45
7.2
1371
1259

45
7.2
6.42
2.14

EN 12900/CECOMAF
45C (113F)
32C (90F)
32C (90F)
45C (113C)
Fan F2
115/60

watt

Current consumption (ASHRAE, EN12900/CECOMAF)


Evap. temp in F
Evap. temp in C
ASHRAE MBP
EN 12900

a2

b
a2

Start winding

e
5

Main winding
R

Thermostat

Motor protector
M

(pos.1)

Design limits:
Max. cond. temp. F (C) stable
Max. cond. temp. F (C) peak
preliminary data

120 (49)
135 (58)

8433

Accessories
Devices

Fig.

CSR (pos.1)

117-7114

Devices

Fig.

CSR/CSIR (pos.1 & pos.2)

Starting relay

a2

117-7441

Starting capacitor 410 F

117U5028

Cover

Protector

Protector holder

Run capacitor 23.5 F

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

a2

in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)

b
a2
Start winding

c
Main winding
R

(117U1021)
parts of
compressor

(117U3212)

Thermostat

(117U0438)
118-1917
118-1918
118-1919

CJ.54.E1.22

CK.54.B6.02

Motor protector

(pos.2)

September 2002

93

SC10DL
MBP/HBP Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.V1.02)
General
SC10DL

Code number

104L2525

104L

SC10DL
Application

R404A
R407C R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP/HBP

Barcode on
white background

-15 to 15

Yellow background

2525

DANFOSS COMPRESSORS

8306

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

600

1300

cm3

1410

kg

13.1

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

385

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

70
150

Motor size

EN 60 335-2-34

127
165
186
218

D
Dimensions

Suction connector

mm

location/I.D. mm

209

203

B1

183

B2

100

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

Height

19
9.7

127
101.6
35

Motor

37

37

107

September 2002

94

CF.54.V2.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

10.29

8258

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10DL

-15
480

-10
636

-5
821

watt
0
1039

5
1293

7.2
1417

10
1588

15
1927
c

Capacity (ASHRAE)
Comp.\C
SC10DL

-15
515

-10
682

watt
-5
881

0
1114

5
1388

7.2
1522

10
1706

15
2073
b
8222

Power consumption
Comp.\C
SC10DL

-15
346

-10
394

watt
-5
437

0
476

5
510

7.2
524

10
540

15
568

a2
d

Current consumption
Comp.\C
SC10DL

-15
2.50

-10
2.66

A
-5
2.81

0
2.95

5
3.08

7.2
3.14

10
3.20

15
3.31

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC10DL

-15
1.39

W/W

-10
1.61

-5
1.88

0
2.18

5
2.54

7.2
2.71

10
2.94

-10
1.73

-5
2.01

0
2.34

5
2.72

7.2
2.91

10
3.16

COP (ASHRAE)
Comp.\C
SC10DL

-15
1.49

15
3.40

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
no subcooling

15
3.65

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC10DL

Starting relay

a2

117U6005

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.V2.02

CK.54.B6.02

September 2002

95

SC12DL
MBP/HBP Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.W1.02)
General
SC12DL

Code number

104L2625

104L

SC12DL
Application

R404A
R407C R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP/HBP

Barcode on
white background

-15 to 15

Yellow background

2625

DANFOSS COMPRESSORS

8306-3

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm 3

Oil quantity

cm3

600

1300

cm3

1460

kg

13.6

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

495

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

70
150

Motor size

EN 60335-2-34

127
165
186
218

D
Dimensions
A

219

213

B1

193

B2

110

location/I.D. mm

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Suction connector

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

mm

Height

19
9.7

127
101.6
35

Motor

37

37

107

September 2002

96

CF.54.W2.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

12.87

8258

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC12DL

-15
632

-10
831

-5
1065

watt
0
1340

5
1660

7.2
1817

10
2031

15
2456
c

Capacity (ASHRAE)
Comp.\C
SC12DL

-15
677

-10
891

watt
-5
1143

0
1438

5
1783

7.2
1951

10
2182

15
2642
b
8222

Power consumption
Comp.\C
SC12DL

-15
456

-10
512

watt
-5
562

0
606

5
643

7.2
658

10
675

15
700

a2
d

Current consumption
Comp.\C
SC12DL

-15
3.11

-10
3.31

A
-5
3.49

0
3.65

5
3.79

7.2
3.85

10
3.91

15
4.01

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC12DL

-15
1.39

W/W

-10
1.62

-5
1.89

0
2.21

5
2.58

7.2
2.76

10
3.01

-10
1.74

-5
2.03

0
2.37

5
2.77

7.2
2.97

10
3.23

COP (ASHRAE)
Comp.\C
SC12DL

-15
1.48

15
3.51

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
45C
32C
no subcooling

15
3.77

Start winding
Main winding
Winding protector

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC12DL

Starting relay

a2

117U6019

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

118-1917
118-1918
118-1919

CF.54.W2.02

CK.54.B6.02

September 2002

97

SC15DL
MBP/HBP Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.X1.02)
General
SC15DL

Code number

104L2856

104L

SC15DL
Application

R404A
R407C R507

Lilac stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP/HBP

Barcode on
white background

-15 to 15

Yellow background

2856

DANFOSS COMPRESSORS

8306-5

Compressor

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm 3

Oil quantity

cm3

600

1300

cm3

1460

kg

13.5

Free gas vol. in compressor


Weight without electrical equipment

204
178
170

16

LRA (rated after 4 sec. UL984) HST

watt

550

21.8

Cut-in current HST

21.8

Resistance, main and start winding (25C)

3.5/12.2

Approvals

70
150

Motor size

EN 60 335-2-34

127
165
186
218

D
Dimensions
A

219

213

B1

193

B2

110

location/I.D. mm

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Suction connector

pcs.

E
B A

B1
B2

255

80

55

63

151

Compressors on a pallet

mm

Height

19
9.7

127
101.6
35

Motor

37

37

107

September 2002

98

CF.54.X2.02

CK.54.B6.02

107
115

55
63

Maximum refrigerant charge

15.28

8257

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15DL

-15
777

-10
1011

-5
1293

watt
0
1629

5
2023

7.2
2217

10
2483

Capacity (ASHRAE)
Comp.\C
SC15DL

-15
833

-10
1084

15
3014

a3
a2

watt
-5
1387

0
1748

5
2173

7.2
2381

10
2668

15
3241

c
8227

Power consumption
Comp.\C
SC15DL

-15
534

-10
590

watt
-5
640

0
686

5
726

7.2
742

10
761

15
790

-5
3.30

0
3.50

5
3.67

7.2
3.74

10
3.82

15
3.94

Current consumption
Comp.\C
SC15DL

-15
2.84

-10
3.08

COP (EN 12900/CECOMAF)


Comp.\C
SC15DL

-15
1.45

-10
1.71

-5
2.02

W/W
0
2.37

5
2.79

7.2
2.99

10
3.26

COP (ASHRAE)
Comp.\C
SC15DL

-15
1.56

15
3.82

b
e

Start winding
5

a2

Main winding
Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3

W/W
-10
1.84

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-5
2.17

0
2.55

5
2.99

EN 12900/CECOMAF
45C
32C
no subcooling

7.2
3.21

10
3.51

15
4.10

Thermostat

Fan

ASHRAE
45C
32C
32C

Accessories
Devices

Fig.

SC15DL

a3

117-7028 (470 mm cable length)


117-7029 (550 mm cable length)
117-7032 (650 mm cable length)
103N2009

Starting device

Cover

Starting relay

a2

Starting capacitor 80 F

Run capacitor

Cord relief

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

September 2002

Components
of
starting device
103N1004
118-1917
118-1918
118-1919

CF.54.X2.02

CK.54.B6.02

September 2002

99

SC10/10DL
MBP/HBP Twin Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.Y1.02)
General
SC10/10DL

Code number

104L4091

Application
Application

MBP/HBP

Evaporating temperature range


Voltage range

-15 to 15

V/Hz

SC10/10DL
Application

104L

R404A
R407C R507

Lilac stripe
Approvals

4091

Barcode on
white background

8307

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2820

kg

26.8

Free gas vol. in compressor

100

Weight without electrical equipment

127

Maximum refrigerant charge

2 x 10.29

Motor
Motor size

watt

127

2 x 385

LRA (rated after 4 sec. UL984) HST*

14.8

Cut-in current HST*

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

16

175

302

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

September 2002

100

CF.54.Y2.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10/10DL

-15
961

-10
1272

-5
1642

watt
0
2077

5
2586

7.2
2835

10
3176

15
3855
Starting relay
Starting capacitor

Comp.\C
-15
SC10/10DL 1030

-10
1364

watt
-5
1761

0
2229

5
2776

7.2
3045

10
3412

-5
874

0
951

5
1020

7.2
1047

10
1081

Power consumption

10 11
12

Main winding

15
4146

14

1
2
N
L

-15
693

-10
788

1
2
N
L

watt

Current consumption
-15
5.00

-10
5.32

0
5.90

5
6.16

7.2
6.27

10
6.40

0
2.18

5
2.54

7.2
2.71

10
2.94

COP (EN 12900/CECOMAF)


Comp.\C
SC10/10DL

-15
1.39

-10
1.61

-5
1.88

13

14

1
2
N
L

Time delay relay


Thermostat 2

Fan

Safety pressure control

A
-5
5.62

12

Blue
Black
Brown

15
1135
Thermostat

Comp.\C
SC10/10DL

Start winding
Winding
protector

1
2
N
L

2 1

Comp.\C
SC10/10DL

10 11
13

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

15
6.63

Remove wire 1-2 if thermostat 2 is used

W/W
15
3.40

service valve
seal ring

COP (ASHRAE)
Comp.\C
SC10/10DL

-15
1.49

W/W
-10
1.73

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-5
2.01

0
2.34

5
2.72

EN 12900/CECOMAF
45C
32C
no subcooling

7.2
2.91

10
3.16

15
3.65
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC10/10DL

Starting relay

117U6005

Starting capacitor 80 F

117U5017

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CF.54.Y2.02

CK.54.B6.02

September 2002

101

SC12/12DL
MBP/HBP Twin Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CF.54.Z1.02)
General
SC12/12DL

Code number

104L4092

Application
Application

MBP/HBP

Evaporating temperature range


Voltage range

-15 to 15

V/Hz

SC12/12DL
Application

104L

R404A
R407C R507

Lilac stripe
Approvals

4092

Barcode on
white background

8307-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Displacement

cm 3

2 x 12.87

Oil quantity

cm3

1220

2200

cm3

2920

kg

27.8

Maximum refrigerant charge


Free gas vol. in compressor

100

Weight without electrical equipment

127

Design

Motor
Motor size

watt

127

2 x 495

LRA (rated after 4 sec. UL984) HST*

18.6

Cut-in current HST*

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

16

175

302

EN 60 335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

B1
B2

1"-14 UNF

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8260

18

326

September 2002

102

CF.54.Z2.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


Comp.\C
-15
SC12/12DL 1263

-10
1662

-5
2130

watt
0
2680

5
3321

7.2
3634

10
4062

15
4913
Starting relay
Starting capacitor

Comp.\C
-15
SC12/12DL 1354

-10
1781

watt
-5
2285

0
2876

5
3566

7.2
3903

10
4364

-5
1124

0
1212

5
1287

7.2
1316

10
1350

Power consumption

10 11
12

Main winding

15
5284

14

1
2
N
L

-15
912

-10
1025

1
2
N
L

watt

Current consumption
-15
6.23

-10
6.62

0
7.30

5
7.58

7.2
7.69

10
7.82

0
2.21

5
2.58

7.2
2.76

10
3.01

COP (EN 12900/CECOMAF)


Comp.\C
SC12/12DL

-15
1.39

-10
1.62

-5
1.89

13

14

1
2
N
L

Time delay relay


Thermostat 2

Fan

Safety pressure control

A
-5
6.98

12

Blue
Black
Brown

15
1400
Thermostat

Comp.\C
SC12/12DL

Start winding
Winding
protector

1
2
N
L

2 1

Comp.\C
SC12/12DL

10 11
13

1933

Capacity (ASHRAE)

Remove wire L-1 if time delay is used

15
8.03

Remove wire 1-2 if thermostat 2 is used

W/W
15
3.51

service valve
seal ring

COP (ASHRAE)
Comp.\C
SC12/12DL

-15
1.48

W/W
-10
1.74

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-5
2.03

0
2.37

5
2.77

EN 12900/CECOMAF
45C
32C
no subcooling

7.2
2.97

10
3.23

15
3.77
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC12/12DL

Starting relay

117U6019

Starting capacitor 80 F

117U5017

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector (alternative)

104B0584
(12 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

September 2002

CF.54.Z2.02

CK.54.B6.02

September 2002

103

SC15/15DL
MBP/HBP Twin Compressor
R407C
220-240V 50Hz
Data Sheet (Replaces CJ.54.A1.02)
General
SC15/15DL

Code number

104L4093

Application
Application

MBP/HBP

Evaporating temperature range


Voltage range

-15 to 15

V/Hz

SC15/15DL
Application

104L

R404A
R407C R507

Lilac stripe
Approvals

4093

Barcode on
white background

8307-2

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Displacement

cm 3

2 x 15.28

Oil quantity

cm3

1220

2200

cm3

2920

kg

28.0

Maximum refrigerant charge


Free gas vol. in compressor

100

Weight without electrical equipment

127

Design

Motor
Motor size

watt

127

2 x 550

LRA (rated after 4 sec. UL984) HST*

21.8

Cut-in current HST*

21.8

Resistance, main and start winding (25C)

3.5/12.1

Approvals

16

175

302

EN 60 335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

259

254

B1

193

B2

110

B1
B2

1"-14 UNF

location/I.D. mm

16

Solder connector

location/I.D. mm

16

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector
Service valve

8265

18

326

September 2002

104

CJ.54.A2.02

CK.54.B6.02

September 2002

Capacity (EN 12900/CECOMAF)


-10
2022

watt

-5
2586

0
3257

5
4047

7.2
4434

10
4966

-5
2774

0
3495

5
4345

7.2
4763

10
5336

Capacity (ASHRAE)
Comp.\C
-15
SC15/15DL 1665

-10
2168

-10
1180

-15
5.68

-10
6.17

-5
1281

0
1372

5
1452

7.2
1484

10
1521

-15
1.45

-10
1.71

1
2
N
L

-5
6.60

0
6.99

5
7.34

7.2
7.47

10
7.63

-5
2.02

0
2.37

5
2.79

7.2
2.99

10
3.26

15
7.88

1
2
N
L

15
1579

COP (EN 12900/CECOMAF)


Comp.\C
SC15/15DL

15
6482

watt

Current consumption
Comp.\C
SC15/15DL

Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance

watt

Power consumption
Comp.\C
-15
SC15/15DL 1069

15
6027

1
2
N
L

2 1

Thermostat

1932

Comp.\C
-15
SC15/15DL 1554

1
2
N
L

Blue
Black
Brown

Time delay
relay
Safety pressure control

Remove wire L-1 if time delay is used

Fan

Thermostat 2

Remove wire 1-2 if thermostat 2 is used

W/W
15
3.82

service valve
seal ring

COP (ASHRAE)
Comp.\C
SC15/15DL

-15
1.56

W/W
-10
1.84

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

-5
2.17

0
2.55

5
2.99

EN 12900/CECOMAF
45C
32C
no subcooling

7.2
3.21

10
3.51

15
4.10
seal ring

ASHRAE
45C
32C
32C

8214

solder connector

Accessories
Devices

pcs.

SC15/15DL

117-7028 (470 mm cable length)


117-7029 (550 mm cable length)
117-7032 (650 mm cable length)

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7351
(16 mm)

Solder connector (alternative)

118-7405
(16 mm)

Seal ring for service valve


and solder connector

118-3638

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

118-1917
118-1918

Starting device

September 2002

CJ.54.A2.02

CK.54.B6.02

September 2002

105

106

CK.54.B6.02

September 2002

September 2002

CK.54.B6.02

107

The Danfoss product programme


for the refrigeration industry contains:

Compressors for Refrigeration and Air Conditioning


A wide range of hermetic reciprocating compressors and scroll compressors
as well as aircooled condensing units. The product range is applied in air
conditioning units, water chillers and commercial refrigeration systems.

Compressors for Refrigerators and Freezers


Hermetic compressors and fan-cooled condensing units for household
refrigeration units such as refrigerators and freezers, and for commercial
installations such as sales counters and bottle coolers. Compressors for
heating pump systems. 12 and 24 V compressors for refrigerators and
freezers in commercial vehicles, buses, and boats.

Appliance Controls
For the regulation of refrigeration appliances and freezers Danfoss supply a
CFC-free product range of electromechanical thermostats for refrigerators
and electromechanical thermostats for refrigerators and freezers produced
according to customer specification; Hermetic valves for refrigerator/freezer
combinations and for energy saving applications; Service thermostats for all
refrigerating and freezing appliances.

Refrigeration and Air Conditioning Controls


With our full product range we cover all the requirements for mechanical
and electronically controlled refrigeration systems. The functions cover: control,
safety, system protection and monitoring. Our products are applied for all
commercial- and industrial refrigeration applications as well as for air
conditioning.

www.danfoss.com/compressors

CK.54.B6.02