Академический Документы
Профессиональный Документы
Культура Документы
Datasheet
Features Compact plug-in design 2 or 3 C/O contacts Standard mechanical indicator Round and silver relay pins for excellent connection in socket Wide range sockets Universal pinning Transparent cover Cadmium free contacts LED optional
Benefits Proven reliability Light weight construction Long term availability Universal pinning Competitive price
Application
Our general purpose relays are applied mainly in industrial and power automation systems, in signaling and protection systems and in other control and electric drives systems.
Industry compliancy EN 60255 Relay design and environmental conditions EN 60947 Low voltage switch gear and control gear EN 60947-5-1 Electromechanical control circuit devices and switching elements IEC 61810 Electromechanical elementary relays The relays meet the requirements of the RoHS directive
Description
The basic features of the general purpose relays are: Number of contacts: 2 or 3 Rated contact switching current 10 A Versions with coil overvoltage suppression Versions with flag indicators and manual relay test pushbuttons with the possibility of lachting the normal open contacts close Mounting sockets for 35 mm rail (EN 50022) Rail sockets equiped with screw terminals or spring terminals
1 www.nieaf-smitt.com
G-relays
Technical specifications
Test button
Transparant cover
Universal pinning
Mechanical indicator
Connection diagram
G08
A1(2)+ 11(1) 31(8)
G11
A1(2)+
11(1)
21(6)
31(11)
A2 (7)-
A2 (7)-
2 www.nieaf-smitt.com
G-relays
Technical specifications
Coil data DC-versions
Operating time at nominal voltage Pull-in time Release time Operating voltage range in % Nominal power consumption Min hold-up voltage
Coil code Rated voltage Un VDC
12 24 48 110 220
12 24 48 115 230
3 www.nieaf-smitt.com
G-relays
Technical specifications
Contact data
Maximum make current Maximum continuous current Maximum switching voltage Minimum switching voltage/current AgNi Material Contact resistance 10 A 6 A (AC1; IEC 60947) 250 V, 400 V 5 V / 5 mA AgNi <100 m
Performance characteristics
Electrical life (AC1) Mechanical life Dielectric strength > 2 x 105 > 2 x 107 cycles (Unpowered) Input output 4000 VAC Mass input output 2500 VAC Contact clearance 1000 VAC C400 At rated load 360 cycles/hour (AC1) No load 72000 cycles/hour
Mechanical data
Dimensions (d x w x h) Weight 35 x 35 x 54.4 mm 83 g
Environment conditions
Storage temperature Operating temperature Shock & vibrations Environment protection Degree of protection EN 116000-3 EN 60529 -40 C+70 C AC -40 C+55 C DC -40 C+60 C Shocks: 10 g Vibrations: 5 g, 10-150 Hz RTI IP20
4 www.nieaf-smitt.com
G-relays
G08
Technical specifications
Dimensions
G11
54,4
Options
Code
L
35
35
13
Description
LED
Timer module
COM- 3TP Turns a general purpose G- relay into a multifunctional timer relay. Suitable for VG-8T and VG-11T sockets
Function and time setting by dip-switch for fine tuning. 8 different functions F Delay - ON R Delay - OFF (+ control contact) Ws One shot - ON (+ control contact) Wa One shot - OFF (+ control contact) Wu One shot - ON Es Delay - ON (+ control contact) Bp Flasher, starting OFF Bi Flasher, starting ON
5 www.nieaf-smitt.com
G-relays
Technical specifications
Electrical life expectancy
The life expectancy values shown below are based on factory tests. These values could be different in real life applications as environmental conditions, switching frequencies and duty cycles will influence these values.
6 www.nieaf-smitt.com
G-relays
VG-8T
VG-11T
VG-8PCB
VG-11PCB
CG-1
T-21
COM-3TP
Sockets
Art. no. 321000206 321000207 321000209 321000210 Type VG-8T VG-11T VG-8PCB Applicable for G11relays, 35 mm rail or wall G08 relays Connection Screw terminals PCB PCB Weight (g) Dimensions (mm) 59 62 9 9 75 x 38 x 26 75 x 38 x 26 28 x 20 28 x 20 G08 relays, 35 mm rail or wall Screw terminals
Accessories
Art. no. 321000203 321000208 321000205 Type CG-1 VG-11T VG-8PCB Applicable for Relay retaining clip on VG-8T & VG-11T sockets, metal Diode module in VG-8T & VG-11T sockets Timer module for VG-8T & VG-11T sockets Weight (g) 6g 15 Dimensions (mm) 44 x 34 x 15 54 x 34 x 15
7 www.nieaf-smitt.com
G-relays
Instructions
Installation, operation, maintenance
Installation
Install the socket and connect wiring according the identification on the terminals, plug the relay into the socket Reverse installation of socket is not possible due to mechanical blocking by pinning Do not reverse the polarity of the coilconnection when a diode is used Relays can be mounted tight next to each other Warning! Never use silicon near by relays!
Operation
Before operate always apply voltage to coil to check correct operation Also switching the load a few times is advised Long term storage may corrode the silver on the relay pins By plugging the relay into the socket, the connector receivers will automatically clean the corrosion on the pins and guarantee a good connection Do not use the relay in places with flammable gas as the arc generated from switching could ignite gasses
Maintenance
Correct operation of relay can easily be checked as transparent cover gives good visibility on the moving contacts When the relay does not appear to operate correct, please check presence of coil voltage Use a multimeter. If LED is used coil presence should be indicated, if coil voltage is present but the relay does not work, a short circuit of suppression diode is possible (The coil connection was reversed) If relay does not work after inspection, please replace the relay by a similar model
8 www.nieaf-smitt.com
G-relays
G08-D012 G08-D024 G08-D048 G08-D110 G08-D120 G08-D220 G08-A012 G08-A024 G08-A048 G08-A110 G08-A230
Ordering codes
G08 relays
12 VDC 24 VDC 48 VDC 110 VDC 120 VDC 220 VDC 12 VAC, 50/60 Hz 24 VAC, 50/60 Hz 48 VAC, 50/60 Hz 110 VAC, 50/60 Hz 230 VAC, 50/60 Hz 321000001 321000002 321000003 321000004 321000010 321000011 321000005 321000006 321000007 321000008 321000009
G11 relays
G11-D012 G11-D024 G11-D030 G11-D048 G11-D110 G11-D120 G11-D220 G11-A012 G11-A024 G11-A048 G11-A110 G11-A230 12 VDC 24 VDC 30 VDC 48 VDC 110 VDC 120 VDC 220 VDC 12 VAC, 50/60 Hz 24 VAC, 50/60 Hz 48 VAC, 50/60 Hz 110 VAC, 50/60 Hz 230 VAC, 50/60 Hz 321000101 321000102 321000111 321000103 321000104 321000110 321000112 321000105 321000106 321000107 321000108 321000109
9 www.nieaf-smitt.com
MS Relais SAS
G-relays -V2.0 May 2012
Tour Rosny 2, Avenue du Gnral de Gaulle, F - 93118 Rosny-sous-Bois Cedex, FRANCE T +33 (0)1 4812 1440, F +33 (0)1 4855 9001 E sales@msrelais.com
Mors Smitt Asia Ltd. # 807, Billion Trade Centre, 31 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E info@morssmitt.hk
Nieaf-Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +31 (0)30 288 1311, F +31 (0)30 289 8816 E sales@nieaf-smitt.nl
Mors Smitt Technologies Inc. 420 Sackett Point Road North Haven, CT 06473, USA T +1 (203) 287 8858, F +1 (888) 287 8852 E mstechnologies@msrelais.com
Mors Smitt UK Ltd. Doulton Road, Cradley Heath West Midlands, B64 5QB, UK
www.nieaf-smitt.com
(c) Copyright 2012 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Nieaf-Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Nieaf-Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.