Вы находитесь на странице: 1из 73

2011 Bentley Systems, Incorporated

AutoPIPE V8i SELECTseries 4 (v9.5)


Mark Upston Director Structural Solutions & PipeStress

New AutoPIPE V8i SELECTseries4 (v9.5.0.x)

Release date, November 2012


2 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Summary

DigitalPlant Pipe Stress Analysis WorkFlow


PlantFLOW
Fluid Flow Analysis Transient Flow Analysis

FEED

PULS
Pulsation Analysis
Equipment Check Pumps, Turbines, Compressors

FEA

Microprotol
Vessel Design

ASME Flange Design

AutoPIPE Nozzle
Nozzle/Vessel Limits

3D Model

AutoPIPE
Pipe Stress Analysis

PID
FEED Isos Marked-Up StressISO 3D Model

Navigator
Hot Clash Detection
Pipe Support Vendor Drawings/ Reports

PlantWise
Conceptual 3D Design

ProjectWise
Project Management

AutoPLANT, PlantSpace, SP3D, PDS, PDMS


Third Party Programs 3D Modeling

STAAD
Structural Analysis

3 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

PID

More than 70 new features

4 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

AutoPIPE V8i SS4 (v9.5) Enhancements

New Advanced Buried Piping Design - Traffic & Seismic loads

Piping Codes: Enhanced Color Graphics Pipe Properties /Segment


FRP piping code ISO 14692 Nuclear JSME 2008

Productivity Improvements Flange Design

Interoperability Improved DGN i-model Export, PCF/PXF import & Caesar Import

5 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

AutoPIPE v9.5 Major Highlights

2011 Bentley Systems, Incorporated

Design Codes

JSME 2008 Design code and JEAC material library Re-certification of Japans nuclear power plants

7 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Piping Code : New JSME 2008 code

Seismic Levels A & As combined in new S level


New Service levels S, B, C, None.

Dynamic Seismic Cases All SAM Levels Supported


8 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Significant Changes in the JSME 2008 Edition

Analysis Summary

Code Compliance Load Cases

9 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

JSME Reports & Load Combinations

New ISO 14692 FRP Piping Code (2005 Addenda)

New FRP Libraries


10 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Piping Codes : New ISO 14692 FRP Code

Pipe ID

Long Term Hoop and Axial Allowable Envelope Stresses Poisson Ratio and A3 Factor for Cyclic Service
11 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

FRP Pipe Properties

Smooth / Miter

Qualified Stress from Manufacturer Biaxial Type and Ratio

Qualified Component

12 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

FRP Bend Component

ISO 14692 FIBERBOND AMERON FIBERCAST SARPLAST CONLEY WAVISTRONG HARVEL REINFORCED PLASTIC SYSTEMS

13 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

FRP Material Library

Component Failure Stress Envelopes Supported


Fully Measured Simplified Rectangular

Component Plain Pipe Bend Tee

Fully Measured Axial & Hoop 1:1 Stress Ratios > 0.1 NA NA

Simplified Axial & Hoop 1:1 Stress Ratios <=0.1 Biaxial ratio R<1 Biaxial ratio R<1

Rectangular Biaxial ratio R => 1 Biaxial ratio R => 1 Biaxial ratio R => 1

Code Compliance

14 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Piping Code : ISO 14692

2011 Bentley Systems, Incorporated

Analysis

Based on exact solution of linear dynamic equations of motion Improved accuracy as problems due to period elongation or numerical damping are avoided

Wilson- is the only available method in CAESAR II unconditionally stable for >1.37. However, this does not mean solution is accurate.
16 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New PieceWise Exact Time History Method

17 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New PieceWise Exact Time History Method

18 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Time History & Response Spectrum Dialogs

Time History Profile o New Option : Imposed Displacement Time History Location

XBD 7 4 0.000000 0.020000 0.030000 0.050000 0.060000 0.061000 0.120000

.0 2. 2. .2 -.7 .0 .0

19 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Displacement Time History

Solution for Piping Vibration


Type of Vibration 1. Mechanical A. Machinery Unbalanced Forces and Moments B. Structure Borne Vibrations 2. Pulsation Flow induced vibrations due to compressors & pumps 3. Pressure Surge, Hydraulic Hammer Force Time History Harmonic Force Analysis AutoPIPE Solution Harmonic Displacement Analysis
2011 Bentley Systems, Incorporated

20 | WWW.BENTLEY.COM

21 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Improved Dialog for defining Harmonic Load

22 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Visualize Individual Frequency Plots or Harmonic Superposition

23 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Model Transient Vibration Effects by Applying Time History Loads

Buoyancy will now be applied to segments NTL import/export Enabled by default

24 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Limit Buoyancy to Selected Segments

Soil weight on top of pipe (including effect of water table) Surface live loads (Highway, Railway, Airport, and user defined) Effect of seismic wave propagation along pipeline (calculated as an equivalent temperature rise) Imposed displacement of support due to building settlement

25 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Advanced Buried Pipeline Design

Circumferential wall bending stress (Adams et. Al., ANSI AWWA C150, and ASCE 2001 w/2005 addenda) Ring buckling category Seismic + Thermal category (Seismic includes SAM and wave propagation effects) Building settlement category

New Soil Stress Categories


26 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Soil Analysis Stress Categories

2011 Bentley Systems, Incorporated

Post Processing

Code Report Code Combinations

28 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

BS7159 User Hoop and Long Allowables

Code Combinations

Non-Code Combinations

29 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

1000 Code and Non-Code Combinations

30 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Modal Frequency Shown on Plot

Scrolling through the Combinations using VCR Buttons updates both Deflected Plot and Results

31 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Deflected Plot & Results Updated

2011 Bentley Systems, Incorporated

Performance

Option

Method
Ctrl+Enter Check Uncheck Check Uncheck Copy Down Check Uncheck

9.4.0.19
48* sec 48* 50* 50* 51* 50* sec sec sec sec sec

latest v9.5 build


1 sec 1 sec 6 sec 6 sec 2 sec 1 sec

Line Number

Drag

Model: BLNE2.DAT with 221 segments.

33 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Segment Grid Optimization (up to 50 times)

2011 Bentley Systems, Incorporated

Modeling

Insert / Modify Run dialog Insert / Modify Bend dialog Insert / Modify Valve dialog Insert / Modify FlexJoint dialog Insert / Modify Reducer dialog Insert / Modify Tee Point dialog

In AutoPIPE following represent the following. Theta r radius z Elevation

symbol

35 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Component Placement using Cylindrical Coordinates

Fluid density can change by temperature and pressure conditions including phase e.g. Steam Change Fluid density for Static, and Dynamic load cases.

36 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Fluid Density Factor

37 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Pipe Identifier Tag e.g. 6 Bypass Line

Demo

New Pressure / Temperature Grid menu options :


Show Show Show Show Pressure Only Temperature Only Pressure and Temperature Only All

38 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Pressure Temperature Input Grid

39 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Plot Reference Point Tag

Go to Point Dialog Go to Origin Origin Symbol and text ViewSettings Show Origin checkbox on the Plot

40 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Where is the Origin? - New Goto Origin

Color Plots of Model Data Pipe Properties Toggle Property, Component and Xtra Data On/OFF while Still Editing the Model

41 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Improved Graphical Show Options

Hint: Continue to model while viewing color plot of segments

42 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Color Plot of All Visible Segments

Hint: Edit the Model while viewing color plot of segments

Pipe Thickness

New Floating Legend

43 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Color Plot of Pipe Properties

Insulation Thickness

44 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Color Plot of Pipe Properties

45 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Isolate and Show Connected Segments

2011 Bentley Systems, Incorporated

Reports

47 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Segment data report

All the Load Combinations which have the highest FAIL Equipment Ratios are identified

48 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Equipment Summary Report

2011 Bentley Systems, Incorporated

Productivity Enhancements for new Flange Analysis & Design Module

Flange Checks to ASME VIII Div 1 & 2 : 2010, ASME III Appendix XI and ASME III NC 3658.1 (b) (ANSI check) Material to ASME II, B31.1 or B31.3

50 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Flange Analysis & Design Module

Flange Material Library Based on Flange Design Code

51 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Default Flange Library

Modify Flange from Flange Analysis Flange Select synchronized with Plot

52 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Flange Synchronization

Restore Sort Order [More Options]

53 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Flange Sort

Hide Incomplete Flanges

54 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Color Coded Incomplete Flange Data

55 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

ANSI Check - User Defined Pmax Pressure

Lethal Service

56 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Analysis Bolt Spacing Correction

New Flag /n to perform automated flange analysis New Flag /l to Create the model input listing (*.RPT)

e.g. AUTOPIPE.EXE VERTICAL HEATER SPOOLS.DAT" /s /l /n /b /y

Switches /s /l /n /b

Description Perform a static analysis. Create the model input listing (*.RPT). Perform a flange analysis. Create the batch report file (*.OUT).

57 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Batch Processing switches

2011 Bentley Systems, Incorporated

Interoperability

Bentley Products
Project Wise STAAD Auto PLANT Plant Space Open Plant ADL Pipe Win NOZL Plant FLOW PULS

AutoPIPE

3rd Party Products


Caesar SP3D PDS PDMS CAD Worx Solid Works Inventor CATIA ME101

AutoPIPE

CAD Products
59 | WWW.BENTLEY.COM

59

2011 Bentley Systems, Incorporated

AutoPIPE Product Interoperability Matrix

Improved Caesar 2011 (v5.3) compatibility Importing more PCF Component Data Improved Roundtrip with AutoPLANT

AutoPIPE
60 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Interoperability & Import /Export

61 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Hot Clash Detection

Automatic Conversion from Y-Vertical to CAD Z Vertical axis

AutoPIPE

MicroStation

62 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Using AutoPIPE & Navigator Hot Clash Detection

To Avoid Design Mistakes and Operation Failure

Bentley Navigator or MicroStation


63 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Using AutoPIPE & Navigator Hot Clash Detection

Caesar has no Flange component AutoPIPE now has smart logic to Convert Caesar RIGID Element to intelligent flanges in AutoPIPE with Flange Spec, Flange Type and Pressure Rating

Flange = RIGID Element Valve = RIGID Element Flange = RIGID Element


64 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Smart Flange Conversion from Caesar

V9.4 : CII Flange -> Valve

V9.5 : Intelligent Flange Conversion

Flange Size Flange Type Flange Rating Flange Spec

65 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Smart Caesar Flange Import

2011 Bentley Systems, Incorporated

AutoPLANT / AutoPIPE Integration

~ 60 Supports

AutoPLANT

AutoPIPE
~ 60 Supports
67 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Intelligent AutoPLANT / AutoPIPE PXF Supports Exchange v9.4

Flange type, Flange length, rating, weight, weld connection, gaskets, bolts

AutoPIPE

AutoPLANT

New Flange CAD Length


68 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Intelligent AutoPLANT / AutoPIPE Flange Exchange v9.5

Actual CAD Flange Length imported

AutoPIPE

AutoPLANT or PCF Formats from SmartPlant, CADWorx, AutoDesk or SolidWorks

Weldneck Flange Graphic

69 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

PXF / PCF 2-Point Flange Component

70 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

PCF Line Number & Class now Imported

Flexible Joint

Cross
71 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

PCF Components now Imported

72 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Import AutoDesk Plant 3D Models

2011 Bentley Systems, Incorporated

Thank you

Вам также может понравиться