Академический Документы
Профессиональный Документы
Культура Документы
Apsf (required surface area) = where Tu = force in N = 1150 t = resistant factor = 0.75 f'c = compressive strength of concrete = Apsf = L= Minimum length of embedment = 12 d =
PROVIDED LENGTH > 4.65 mm or 324 mm CHECK FOR TENSION As per ACI-318 Nsa = n Ase,N futa where Nsa = nominal stregth in tension in Newton n = nos. of bolts in a group. = 4 Ase,N = effective x-sectional area of a single bolt =
d2 4 = 572.265 ( sq. mm) futa = not greater than 1.9 fya or 861.845 N/sq.mm(125000 psi) whichever is less fya = yield strenth of anchor steel in N/sq.mm = 250 Nsa = 1087.3035 KN > 4.6 KN HENCE SAFE CHECK FOR SHEAR As per ACI-318 Vsa = n 0.6 Ase,V futa where Vsa = nominal stregth in shear in pounds n = nos. of bolts in a group. = 4 Ase,V = effective x-sectional area of a single bolt =
d2 4 = 572.265 ( sq. mm) futa = not greater than 1.9 fya or 861.845 N/sq.mm(125000 psi) whichever is less fya = yield strenth of anchor steel in N/sq.mm = 250 Vsa = 652.3821 KN > 16.4 KN HENCE SAFE CHECK FOR PULL OUT As per ACI-318 Npn = c,p Np where Npn = nominal pull out stregth in pounds c,p = modification factor = 1.4 and Np = 8 Abrg f'c where Abrg = net bearing area of bolt head(dia 2d) = = 32
d2 4 2289.06 N/sq.mm
( sq. mm)