Note: The information within this table is based on tertiary sources, original research, particular assumptions and calculations.
between data sources exist. This table should only be used as a general reference. No one is responible for incorrect inform
is the sole responsibility of the user. Use at your own risk.
Diameter (d)
AWG
sizes
0000
000
00
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
inches
0.460000
0.409600
0.364800
0.324860
0.289300
0.257630
0.229420
0.204310
0.181940
0.162020
0.144300
0.128496
0.114400
0.101890
0.090700
0.080808
0.072000
0.064084
0.057100
0.050821
0.045300
0.040303
0.035900
0.031961
0.028500
0.025300
0.022600
0.020100
0.017900
0.015900
0.014200
0.012600
0.011300
0.010000
0.008930
0.007950
0.007100
0.006300
0.005600
0.005000
mm
11.68400
10.40384
9.26592
8.25144
7.34822
6.54380
5.82727
5.18947
4.62128
4.11531
3.66522
3.26380
2.90576
2.58801
2.30378
2.05253
1.82880
1.62773
1.45034
1.29086
1.15062
1.02370
0.91186
0.81181
0.72390
0.64262
0.57404
0.51054
0.45466
0.40386
0.36068
0.32004
0.28702
0.25400
0.22682
0.20193
0.18034
0.16002
0.14224
0.12700
Area
kcmil
(d x 1000
inches)
212
168
133
106
83.7
66.4
52.6
41.7
33.1
26.3
20.8
16.5
13.1
10.4
8.23
6.53
5.18
4.11
3.26
2.58
2.05
1.62
1.289
1.022
0.812
0.640
0.5108
0.4040
0.3204
0.2528
0.2016
0.1588
0.1277
0.10000
0.07974
0.06320
0.05041
0.03969
0.03136
0.02500
Copper resistance
mm
107
85.0
67.4
53.5
42.4
33.6
26.7
21.2
16.8
13.3
10.6
8.37
6.63
5.26
4.17
3.31
2.63
2.08
1.65
1.31
1.04
0.82
0.653
0.518
0.412
0.324
0.259
0.205
0.162
0.128
0.102
0.080
0.065
0.051
0.0404
0.0320
0.0255
0.0201
0.0159
0.0127
ohms per
1000 feet
0.049
0.062
0.078
0.098
0.124
0.156
0.197
0.249
0.313
0.395
0.498
0.628
0.792
0.999
1.260
1.588
2.003
2.525
3.184
4.016
5.064
6.385
8.051
10.15
12.80
16.14
20.36
25.67
32.37
40.81
51.47
64.90
81.84
103.20
130.10
164.10
206.90
260.90
329.00
414.80
ohms per
km
0.161
0.203
0.256
0.322
0.41
0.51
0.65
0.82
1.03
1.30
1.63
2.06
2.60
3.28
4.13
5.21
6.57
8.28
10.45
13.18
16.61
20.95
26.41
33.30
41.99
52.95
66.80
84.22
106.2
133.9
168.9
212.9
268.5
338.6
426.8
538.4
678.8
856.0
1079
1361
Aluminum resistance
ohms per
1000 feet
0.080
0.101
0.128
0.161
0.203
0.256
0.323
0.408
0.514
0.648
0.817
1.030
1.300
1.640
2.070
2.610
3.290
4.140
5.220
6.590
8.310
10.500
13.2
16.7
21.0
26.5
33.4
42.1
53.1
67.0
84.4
106.0
134.0
169.0
213.0
269.0
339.0
428.0
540.0
681.0
37
38
39
40
41
42
43
44
45
46
47
48
49
50
0.004500
0.004000
0.003500
0.003140
0.002800
0.002494
0.002221
0.001978
0.001761
0.001568
0.001397
0.001244
0.001107
0.000986
0.11430
0.10160
0.08890
0.07976
0.07112
0.06335
0.05641
0.05024
0.04473
0.03983
0.03548
0.03160
0.02812
0.02504
0.02025
0.01600
0.01225
0.00986
0.00784
0.00622
0.00493
0.00391
0.003101
0.002459
0.001952
0.001548
0.001225
0.000972
0.0103
0.0081
0.0062
0.0050
0.00397
0.00315
0.00250
0.00198
0.00157
0.00125
0.00099
0.00078
0.00062
0.00049
523.10
659.60
831.80
1049.0
1288.0
1585.1
2070.4
2496.2
3206.2
4057.9
5009.8
6756.1
8281.4
10388.2
1716
2164
2729
3442
4226
5201
6793
8190
10519
13313
16436
22166
27170
34082
858.0
1080.0
1360.0
1720.0
Table
Aluminum resistance
ohms per
km
0.264
0.331
0.420
0.528
0.67
0.84
1.06
1.34
1.69
2.13
2.68
3.38
4.27
5.38
6.79
8.56
10.79
13.58
17.13
21.62
27.26
34.45
43.31
54.79
68.90
86.94
109.58
138.12
174.2
219.8
276.9
347.8
439.6
554.5
698.8
882.5
1112.2
1404.2
1772
2234
Turns of wire
power
transper inch
mission
302
2.17
239
2.44
190
2.74
150
3.08
119
3.46
94
3.88
75
4.36
60
4.89
47
5.5
37
6.17
30
6.93
24
7.78
19
8.74
15
9.81
12
11
9.3
12.4
7.4
13.9
5.9
15.6
4.7
17.5
3.7
19.7
2.9
22.1
2.3
24.8
1.8
27.9
1.5
31.3
1.2
35.1
0.92
39.5
0.729
44.3
0.577
49.7
0.457
55.9
0.361
62.7
0.288
70.4
0.226
79.1
0.182
88.8
0.142
99.7
0.113
112
0.091
126
0.072
159
0.056
200
0.044
252
0.035
318
per cm
0.856
0.961
1.08
1.21
1.36
1.53
1.72
1.93
2.16
2.43
2.73
3.06
3.44
3.86
4.34
4.87
5.47
6.14
6.9
7.75
8.7
9.77
11
12.3
13.8
15.5
17.4
19.6
22
24.7
27.7
31.1
35
39.3
44.1
49.5
62.4
78.7
99.3
125
2815
3543
4462
5643
0.17
0.13
0.11
0.09
0.0289
0.0228
0.0175
0.0137
Note: The information within this table is conservative and is based on tertiary sources, original research, particular assumptio
Additionally, minor variations between data sources exist. This table should only be used as a general reference. No one is re
information found in this table. Use thereof is the sole responsibility of the user. Use at your own risk.
Circuit amps (A)
Length (feet)
@6V
@12V
@6V
@12V
2.5
3
3.5
4
5
5.5
6
7.5
9
10
11
12
15
17.5
20
25
50
75
100
5
6
7
8
10
11
12
15
18
20
22
24
30
38
40
50
100
150
200
15
18
21
24
30
33
36
45
54
60
66
72
90
105
120
150
300
450
600
30
36
42
48
60
66
72
90
108
120
132
144
180
228
240
300
600
900
1200
22
22
22
22
18
18
18
18
18
18
18
18
18
18
18
16
12
10
10
22
22
18
18
18
18
18
18
18
18
18
18
16
16
16
14
12
10
8
22
18
18
18
18
18
18
18
16
16
16
16
16
14
14
12
10
8
8
10
18
18
18
18
18
18
18
18
16
16
16
16
14
12
12
12
10
8
6
Gage selection (AWG)
ble
15
18
18
18
18
16
16
16
14
14
14
12
12
10
10
10
10
6
4
4
Gage selection (AWG)
20
25
18
18
18
16
16
16
16
14
14
12
12
12
10
10
10
10
6
4
4
18
16
16
16
16
14
14
12
12
10
10
10
10
8
8
8
4
2
2
Length (feet)