Вы находитесь на странице: 1из 8

Explosion-Proof

Motors
Increased
Safety
II 2 G
EExe II T3 - T4

Certified to
ATEX Directive 94/9/EC

0344

Product Catalogue

Explosion-Proof Increased Safety Motors

DESCRIPTION OF THE CATALOGUE VERSION


Duty type:
Rated voltage:
Frequency:
Ambient temperature:
Mounting height:
Number of free shaft ends:
Insulation class:

S1
230V, 400V
50 Hz
from -20C to + 40C
up to 1000 m above sea level
1
F

Explosion-proof increased safety motors are adapted for operating in areas endangered by explosion other
than methane mines, (apparatus group II, explosion group II) in zone 1.
Zone 1- covers areas in which the occasional occurrence (>10<1000hrs/annum) of an explosive atmosphere
due to the presence of gases, vapours or mists is likely.
The EExe motors belong to the aparatus category 2G (zone 1, gas hazardous area). 2G means that it is either
necessary to ensure that the occurrence of ignition source Is excluded, or the ignition source must be
encapsulated by a recognized type of protection in such a way that the ignition of an explosive atmosphere
surrounding the motor is prevented.
Classification of temperature classes according to the ignition temperature of explosive atmosphere:
Ignition temperature of explosive atmosphere [C]

Temperature class

Max. temperature of motor [C]

Above 450

T1

450

300 - 450

T2

300

200 - 300

T3

200

135 - 200

T4

135

Specific marking of explosion protection

II
2
G
EEx
e
II
T3

for use in hazardous areas other than mines


apparatus category 2 for use in zone 1
for use in gas hazardous areas
built and tested according to European standards
increased safety

The motors are designed for


the temperature class T3 which
means that the maximum temperature
of any part of the motor can not
exceed + 200C or for
the temperature class T4 where
maximum temperature can not
exceed + 135C.

explosion group
temperature class

ORDERING INFORMATION
Orders for motors should specify:
Motor type designation
Rated output
Rated speed
Operating duty
Supply voltage
Frequency
Mounting arrangements
Degree of protection
Other details of out-of-catalogue or special version
Number of pieces

As part of our development program, we reserve the right


to alter or amend any of the specifications without giving prior notice.

02

Explosion-Proof Increased Safety Motors

TECHNICAL DATA

BEARINGS, DEGREE OF PROTECTION

In the EExe motors there are applied additional means to increase safety in case
of appearance of excessive temperature or occurrence of arcs and sparks inside
the motor and on its external parts. There are special terminal board, terminal box
ensuring suitable insulating distances, certified cable gland, two neutral terminals,
reinforced insulation etc. The parts of motor housing are made of material with
magnesium contents less than 6% apart from the fan cover which is made of steel.
The overload protection of the motor must cause the motor to disconnect from
the supply voltage in a time shorter than the specified time tE when the current
is equal to the starting current. Time tE is the time when, during the flow of
the starting current, the motor winding heats up to the limit temperature from
the temperature of rated conditions at maximum ambient temperature.
For tE please refer to the table with parameters.

Type

Bearings

Protection

Sg 63

6202 2Z

IP 56

Sh 71

6203 2Z

IP 56

Sh 80

6204 2Z

IP 56

Sh 90

6205 2Z

IP 55

Sg 100

6206 2Z

IP 55

Sg 112

6306 2Z

IP 55

Sg 132

6308 2Z

IP 55

Sg 160

6309 2Z

IP 55

Sg 180

6311 2Z

IP 55

The motors can be provided with a cable gland with a holder (protecting the supply wire against pulling out).
The motors that are provided with special fan cover can work in perpendicular position with the shaft down,
However detailed conditions specified in service manual being enclosed to each motor, must be fulfilled.

STANDARDS
The electric motors are manufactured according to
international standards:

Electrical
requirements

Mechanical
requirement

IEC 600 34-1


IEC 600 34-5
IEC 600 34-6
IEC 600 34-9
IEC 600 34-5
IEC 600 34-6
IEC 600 34-7
IEC 600 34-14
IEC 600 72-1

Each motor is manufactured according


to requirements of ATEX Directive 94/9/EC and has
a certificate of conformity with the documentation
approved by N.V. KEMA, Netherlands.
Type Sg63.-

KEMA 03 ATEX2176 for temperature class T3


KEMA 03 ATEX2177 for temperature class T4

Type Sh71.-

KEMA 03 ATEX2178 for temperature class T3


KEMA 03 ATEX2179 for temperature class T4

Type Sh80.-

KEMA 03 ATEX2180 for temperature class T3


KEMA 03 ATEX2181 for temperature class T4

Type Sh90.-

KEMA 02 ATEX2136 for temperature class T3


KEMA 02 ATEX2137 for temperature class T4

Type Sg100.-

KEMA 02 ATEX2138 for temperature class T3


KEMA 02 ATEX2139 for temperature class T4

Type Sg112.-

KEMA 02 ATEX2140 for temperature class T3


KEMA 02 ATEX2141 for temperature class T4

Type Sg132.-

KEMA 02 ATEX2142 for temperature class T3


KEMA 02 ATEX2143 for temperature class T4

Type Sg160.-

KEMA 02 ATEX2144 for temperature class T3


KEMA 02 ATEX2145 for temperature class T4

Type Sg 180.-

KEMA 02 ATEX2146 for temperature class T3


KEMA 02 ATEX2147 for temperature class T4

The motors meet requirements of EN 50014, EN-50019


and EN 13980 (production quality requirements).
The products comply with the specifications regarding
the electromagnetic compatibility specified in:
EN 50081-1, EN 50081-2, EN 50082-1, EN 50082-2.

All the motors are manufactured in


Quality Assurance System
consistent with ISO 9001.
The motors covered by the present catalogue
comply with the regulations and standards
consistent with IEC standards.
All the motors described in present catalogue are
provided with CE mark.
It means that our products are consistent with the
European Union directives regarding the safety features.

03

Explosion-Proof Increased Safety Motors

Totally Enclosed Motors


Insulation Class F

cosjN

IN

TL/TN

IL/IN

Tb/TN

[-]
2p=2
0,82
0,82
0,82
0,72
0,9
0,8
0,86
0,75
0,83
0,78
0,88
0,81
0,78
0,82
0,9
0,88
0,91
0,91
0,91
0,9
0,91
0,91
0,92
0,89
0,9
0,91
0,9
0,92
0,92
0,92
2p=4
0,67
0,67
0,69
0,69
0,69
0,57
0,59
0,72
0,58
0,74
0,64
0,8
0,75
0,77
0,78

[A]230V [A]400V
nS=3000 rpm
0,9
0,5
0,9
0,5
1,2
0,7
1,1
0,6
1,75
1
1,2
0,7
2,4
1,4
1,75
1
3,2
1,8
2,45
1,4
4,15
2,4
6,1
3,5
4
2,3
8,2
4,7
4,2
2,4
8,3
4,8
5,2
3
13
7,5
6,4
3,7
18,1
10,4
8
4,6
22,1
12,7
11,1
6,4
35
20,1
16
9,2
18,6
10,7
49,2
28,3
22,8
13,1
55,3
31,8
30,3
17,4
nS=1500 rpm
0,9
0,5
0,9
0,5
1,1
0,6
1,1
0,6
1,4
0,8
1,2
0,7
2,25
1,3
2,75
1,6
2,25
1,3
3,7
2,1
2,95
1,7
4,7
2,7
3,5
2
6,4
3,7
4,7
2,7

[-]

[-]

[-]

1,9
1,9
2
2,8
2,2
2,8
2
2,9
2,7
2,8
2,6
2,9
3,8
3
3,2
2,7
2,8
2
3
2,4
2,4
2,5
2,8
2,3
3
2,9
2,8
3,2
2,3
2,4

4
4
4,4
5,2
4
5,4
4,4
5,8
4,7
6
5,5
6
7,5
7,1
7,4
8,3
7,8
6,5
7,9
7,1
7,5
7,7
8
6,5
7,7
7,7
7,7
7,8
8,25
8,5

1,9
1,9
2
2,8
2,2
3
2,1
3
2,6
2,9
2,6
3
4,1
3,2
3,2
3
3,1
2,4
3,5
2,7
3,2
3,1
3,4
2,7
3,6
3,3
3,5
3,5
3,4
3,6

39,5
25,8
18,2
12
10,5
7,2
10
5
6
8
9
7
5,6
7
13
-

14,0
11,5
11,8
8,8
6,2
6
6
5,5
15
16
11
8
7
8
14

3,6
3,6
4,2
4,2
5
5
6
6
8
8
9,5
12,5
12,7
15,9
16,5
22,8
22,5
33
33
57
58
76
72
101
101
112
132
129
188
191

2
2
2
2
2
2,7
2
1,7
2,5
1,8
2,5
2
2,6
2,5
2,8

3,4
3,4
3,7
3,7
3,7
4,2
3,6
3,4
4,1
4,6
5,5
4,65
5,7
5,3
6,2

2
2
2
2
2
2,7
2
1,8
2,7
1,8
2,5
2,4
3,1
2,7
3

50,3
41,1
41,7
20,4
16,5
20
14
13
-

18,6
14,2
19,2
11
11,5
10
10

3,6
3,6
4,2
4,2
4,8
4,8
5,9
7,8
7,8
9
9
12,7
12,7
15,5
16

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.

ExSg63-2A-T3
ExSg63-2A-T4
ExSg63-2B-T3
ExSg63-2B-T4
ExSh71-2A-T3
ExSh71-2A-T4
ExSh71-2B-T3
ExSh71-2B-T4
ExSh80-2A-T3
ExSh80-2A-T4
ExSh80-2B-T3
Sh90S-2-T3
Sh90S-2-T4
Sh90L-2-T3
Sh90L-2-T4
Sg100L-2-T3
Sg100L-2-T4
Sg112M-2-T3
Sg112M-2-T4
Sg132S-2A-T3
Sg132S-2A-T4
Sg132S-2B-T3
Sg132S-2B-T4
Sg160M-2A-T3
Sg160M-2A-T4
Sg160M-2B-T4
Sg160L-2-T3
Sg160L-2-T4
Sg180M-2-T3
Sg180M-2-T4

0,18
0,18
0,25
0,18
0,37
0,25
0,55
0,37
0,75
0,55
1,1
1,5
1
2,2
1,2
2,4
1,5
4
2
5,5
2,5
7
3,5
11
5
6
16
7,5
18,5
10

0,25
0,25
0,33
0,25
0,5
0,33
0,75
0,5
1
0,75
1,5
2
1,36
3
1,6
3,3
2
5,5
2,7
7,5
3,4
9,4
4,8
15
6,8
8,1
21,4
10
25
13,6

2710
2710
2770
2840
2680
2830
2720
2850
2760
2850
2780
2850
2895
2860
2855
2905
2900
2875
2915
2915
2930
2920
2935
2920
2945
2950
2940
2950
2945
2950

0,63
0,63
0,86
0,61
1,32
0,84
1,93
1,24
2,6
1,85
3,7
5
3,3
7,35
4
7,9
4,9
13,3
6,5
18
8,1
22,9
11,4
36
16,2
19,4
52
24,3
60
32,4

60
60
64
62
59
65
67
70
73
71
75
77,8
79,6
81,7
79,5
81,7
79,2
85,5
85,8
85,3
85,2
87,3
86,1
88,1
87,7
88,7
90,8
90
91,6
90,4

31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.

ExSg63-4A-T3
ExSg63-4A-T4
ExSg63-4B-T3
ExSg63-4B-T4
ExSh71-4A-T3
ExSh71-4A-T4
ExSh71-4B-T3
ExSh80-4A-T3
ExSh80-4A-T4
ExSh80-4B-T3
ExSh80-4B-T4
Sh90S-4-T3
Sh90S-4-T4
Sh90L-4-T3
Sh90L-4-T4

0,12
0,12
0,18
0,18
0,25
0,18
0,37
0,55
0,37
0,75
0,55
1,1
0,8
1,5
1,1

0,17
0,17
0,25
0,25
0,33
0,25
0,5
0,75
0,5
1
0,75
1,5
1,07
2
1,5

1380
1380
1370
1370
1350
1400
1350
1370
1420
1370
1420
1405
1435
1415
1430

0,83
0,83
1,25
1,25
1,77
1,23
2,62
3,8
2,5
5,2
3,7
6,8
5,3
10,1
7,3

50
58
62
62
65
66
68
71
72
71
74
72,9
75,8
75,5
76

T3

Weight (IMB3)

Heating time tE

hN
[%]

Full-load amps
at rated voltage

TN
[Nm]

Power factor

nN

Rated efficiency

Breakdown torque

[HP]

Rated torque

Locked rotor current

TECHNICAL DATA
04

Locked rotor torque

PN
[kW]

[rpm]

Rated speed

Rated output

Type of motor

Item

II 2 G EExe II T3
II 2 G EExe II T4

T4
[s]

m
kg

Explosion-Proof Increased Safety Motors

Totally Enclosed Motors


Insulation Class F

Locked rotor current

Breakdown torque

TL/TN

IL/IN

Tb/TN

[-]
2p=4
0,8
0,83
0,81
0,85
0,85
0,84
0,84
0,85
0,86
0,87
0,85
0,87
0,86
0,88
0,89
0,9
0,92
2p=6
0,66
0,7
0,66
0,72
0,6
0,73
0,68
0,71
0,61
0,73
0,74
0,77
0,73
0,8
0,78
0,82
0,8
0,82
0,83
0,8
0,81
0,82
0,84
0,82

[A]230V [A]400V
nS=1500 rpm
9
5,2
5,7
3,3
12
6,9
7,5
4,3
14,4
8,3
8,5
4,9
19,3
11,1
10,4
6
25,4
14,6
13,4
7,7
36,7
21,2
19,7
11,3
48,7
28
24
13,8
57,4
33
66,6
38,3
33,6
19,3
nS=1000 rpm
1,4
0,8
1,75
1
2,25
1,3
2,95
1,7
2,25
1,3
3,7
2,1
3,5
2
5,2
3
4,5
2,6
7,1
4,1
5,6
3,2
8,9
5,1
6,8
3,9
11,8
6,8
8,9
5,1
14,8
8,5
10,4
6
20,2
11,6
14,3
8,2
27,3
15,7
19,5
11,2
38,3
22
23,7
13,6
46,3
26,6

[-]

[-]

[-]

2,4
2,6
2,6
2,4
2,5
3
2,2
2,3
2,3
2,2
2,2
2
2,3
2,2
2,8
2,8
2

5,9
6,2
5,75
6,2
6,9
7,9
6,8
7,7
7
7,4
7,2
7,3
7,4
7,6
7,9
7,7
5,8

2,8
3,1
2,9
2,7
3
3,7
2,8
3
2,8
3
3,1
2,8
3
2,9
2,7
2,6
2,3

9
9
7
7
5
9
8
5
5
-

10
7
8
8
7
14
12
7

21,9
22,1
24
23,9
33
33
60
60
71
71
104
105
126
127
173
200
199

1,9
1,6
2
1,9
2,7
1,9
2,3
2,2
3,1
2,1
2,3
2,3
2,8
2,1
2,3
2,3
2,4
2,7
2,5
2,2
2,2
2,3
2,4
3,2

2,8
2,8
3
3,1
4
3,7
4,1
4,05
4,8
4,5
4,8
5,9
6,7
5,3
5,9
6,1
6,5
6,4
7
6,5
6,7
6,8
7,5
6,7

1,9
1,6
2,1
2
3
2,1
2,6
2,5
3,3
2,4
2,7
2,7
3,4
2,8
3
2,9
2,9
3,4
3,5
2,8
2,9
3,3
3,1
2,4

26
22,1
30
22
32
33
17
19
18
14
8
10
8
8

18
18
18
12
12
11
12
5,5
7
8
-

4,9
5,8
7,5
8,9
8,9
12,1
12,4
15,5
15,5
21
22,1
32
32
52
52
64
63
71
71
99
101
126
125
169

2,2
1,5
3
2
4
2,4
5,5
3
7,5
4
11
6
15
7,5
18,5
22
11

3
2
4
2,7
5,5
3,3
7,5
4
10
5,5
15
8,1
20
10
25
30
15

1425
1430
1415
1425
1430
1450
1455
1465
1450
1460
1460
1465
1460
1465
1470
1465
1465

14,7
10
20,2
13,4
26,7
15,8
36,1
19,5
49,4
26,2
72
39,1
98,1
48,9
120
143
71,7

77,1
78,1
78
79,8
82,6
83,8
84,5
85,5
85,9
86,2
88,5
88,6
89,7
89,4
91,4
91,7
89,8

63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.

ExSh71-6A-T3
ExSh71-6B-T3
ExSh80-6A-T3
ExSh80-6B-T3
ExSh80-6B-T4
Sh90S-6-T3
Sh90S-6-T4
Sh90L-6-T3
Sh90L-6-T4
Sg100L-6-T3
Sg100L-6-T4
Sg112M-6-T3
Sg112M-6-T4
Sg132S-6-T3
Sg132S-6-T4
Sg132M-6A-T3
Sg132M-6A-T4
Sg132M-6B-T3
Sg132M-6B-T4
Sg160M-6-T3
Sg160M-6-T4
Sg160L-6-T3
Sg160L-6-T4
Sg180L-6-T3

0,18
0,25
0,37
0,55
0,37
0,75
0,65
1,1
0,8
1,5
1,2
2,2
1,6
3
2,2
4
2,8
5,5
4
7,5
5,5
11
7
13,5

0,25
0,33
0,5
0,75
0,5
1
0,88
1,5
1,07
2
1,6
3
2,1
4
3
5,5
3,8
7,5
5,5
10
7,5
15
9,4
18

890
870
910
880
940
915
935
920
950
945
950
960
970
945
960
950
960
950
960
960
965
960
970
980

1,93
2,74
3,9
5,9
3,75
7,82
6,6
11,4
8
15,2
12,1
21,9
15,7
30,3
21,9
40,2
27,8
55,3
39,8
74,6
54,4
109,4
68,9
131

49
51
62
65
68
69,8
71,1
73,3
73,9
72,5
73,7
81,2
81,1
79,7
80,7
82,9
84,3
83,3
84,8
86,3
87,2
87,5
88,6
89,3

T4
[s]

m
kg

TECHNICAL DATA

Sg100L-4A-T3
Sg100L-4A-T4
Sg100L-4B-T3
Sg100L-4B-T4
Sg112M-4-T3
Sg112M-4-T4
Sg132S-4-T3
Sg132S-4-T4
Sg132M-4-T3
Sg132M-4-T4
Sg160M-4-T3
Sg160M-4-T4
Sg160L-4-T3
Sg160L-4-T4
Sg180M-4-T3
Sg180L-4-T3
Sg180L-4-T4

T3

Weight (IMB3)

Rated speed

Rated output

46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.

Heating time tE

Locked rotor torque

IN

[%]

Full-load amps
at rated voltage

cosjN

[Nm]

Power factor

hN

[rpm]

Rated efficiency

TN

[HP]

PN

Rated torque

nN

[kW]

Type of motor

Item

II 2 G EExe II T3
II 2 G EExe II T4

05

Explosion-Proof Increased Safety Motors

FOOT MOUNTED MOTORS - IMB 3

L*
L

A-A

HD
D

HA

AA

K
C

K1
A

CA

AB

BB

Type of motor
ExSg63-.A
ExSg63-.B
ExSh71-.A
ExSh71-.B
ExSh80-.A
ExSh80-.B
Sh90S-.
Sh90L-.
Sg100L-.
Sg112M-.
Sg132S-.
Sg132S-2B
Sg132M-.
Sg160M-.
Sg160L-.
Sg180M-2
Sg180M-4
Sg180L-4
Sg180L-6

06

AC

GA

DIMENSION DRAWINGS

CA

100
100
112
112
125
125
140
140
160
190
216
216
216
254
254
279
279
279
279

80
80
90
90
100
100
100
125
140
140
140
140
178
210
254
241
241
279
279

40
40
45
45
50
50
56
56
63
70
89
89
89
108
108
121
121
121
121

67
79
65
83
87
99
104
104
116
119
160
198
160
200
200
256
243
256
243

11j6
11j6
14j6
14j6
19j6
19j6
24j6
24j6
28j6
28j6
38k6
38k6
38k6
42k6
42k6
48k6
48k6
48k6
48k6

23
23
30
30
40
40
50
50
60
60
80
80
80
110
110
110
110
110
110

4h9
4h9
5h9
5h9
6h9
6h9
8h9
8h9
8h9
8h9
10h9
10h9
10h9
12h9
12h9
14h9
14h9
14h9
14h9

GA
12,5
12,5
16
16
21,5
21,5
27
27
31
31
41
41
41
45
45
51,5
51,5
51,5
51,5

K1

Gland

AA

AB

AC

BB

HA

63
63
71
71
80
80
90
90
100
112
132
132
132
160
160
180
180
180
180

7
7
7
7
10
10
10
10
12
12
12
12
12
15
15
15
15
15
15

10
10
10
10
13
13
-

M20
M20
M20
M20
M20
M20
M20
M20
M20
M25
M32
M32
M32
M40
M40
M40
M40
M40
M40

36
36
45
45
55
55
50
50
45
54
56
56
56
60
60
70
70
70
70

124
124
142
142
160
160
170
170
200
230
278
278
278
305
305
350
350
350
350

126
126
141
141
150
150
185
185
206
245
274
274
274
323
323
360
360
360
360

106
106
116
116
130
130
153
153
172
174
182
220
220
256
300
320
320
320
320

8,5
8,5
8
8
9
9
10
10
14
14
16
16
16
20
20
26
26
26
26

HD
185
185
202
202
222
222
220
220
240
276
330
330
330
370
370
408
408
408
408

L/L*

Bearings

202/228
214/240
223/249
245/271
266/283
278/303
305/329
330/354
376/421
384/429
463/516
501/554
501554
612/665
656/709
876/929
705/758
756/809
705/758

6202 2Z
6202 2Z
6203 2Z
6203 2Z
6204 2Z
6204 2Z
6205 2Z
6205 2Z
6206 2Z
6306 2Z
6308 2Z
6308 2Z
6308 2Z
6309 2Z
6309 2Z
6311 2Z
6311 2Z
6311 2Z
6311 2Z

Explosion-Proof Increased Safety Motors

FLANGE MOUNTED MOTORS - IM B5, IM B14

IM B5
ExSKg63-.A
ExSKg63-.B
ExSKh71-.A
ExSKh71-.B
ExSKh80-.A
ExSKh80-.B
SKh90S-.
SKh90L-.
SKg100L-.
SKg112M-.
SKg132S-.
SKg132S-2B
SKg132M-.
SKg160M-.
SKg160L-.
SKg180M-2
SKg180M-4
SKg180L-4
SKg180L-6

Flange
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5

A-A

GA

LA

Gland

AC

HB

L/L*

140
140
160
160
200
200
200
200
250
250
300
300
300
350
350
350
350
350
350

115
115
130
130
165
165
165
165
215
215
265
265
265
300
300
300
300
300
300

95j6
95j6
110j6
110j6
130j6
130j6
130j6
130j6
180j6
180j6
230j6
230j6
230j6
250j6
250j6
250j6
250j6
250j6
250j6

10
10
10
10
12
12
12
12
15
15
15
15
15
19
19
19
19
19
19

11j6
11j6
14j6
14j6
19j6
19j6
24j6
24j6
28j6
28j6
38k6
38k6
38k6
42k6
42k6
48k6
48k6
48k6
48k6

23
23
30
30
40
40
50
50
60
60
80
80
80
110
110
110
110
110
110

4h9
4h9
5h9
5h9
6h9
6h9
8h9
8h9
8h9
8h9
10h9
10h9
10h9
12h9
12h9
14h9
14h9
14h9
14h9

12,5
12,5
16
16
21,5
21,5
27
27
31
31
41
41
41
45
45
51,5
51,5
51,5
51,5

9
9
9
9
10
10
8
8
11
12
12
12
12
13
13
13
13
13
13

3
3
3,5
3,5
3,5
3,5
3,5
3,5
4
4
4
4
4
5
5
5
5
5
5

M20
M20
M20
M20
M20
M20
M20
M20
M20
M25
M32
M32
M32
M40
M40
M40
M40
M40
M40

126
126
141
141
150
150
185
185
206
245
274
274
274
323
323
360
360
360
360

114
114
119
119
127
127
130
130
140
164
198
198
198
210
210
228
228
228
228

202/228
214/240
223/249
245/271
266/283
278/303
305/329
330/354
376/421
384/429
463/516
501/554
501/554
612/665
656/709
756/809
705/758
756/809
705/758

LE

Bearings
6202 2Z
6202 2Z
6203 2Z
6203 2Z
6204 2Z
6204 2Z
6205 2Z
6205 2Z
6206 2Z
6306 2Z
6308 2Z
6308 2Z
6308 2Z
6309 2Z
6309 2Z
6311 2Z
6311 2Z
6311 2Z
6311 2Z

LA

HB

GA

45

P
N

P
N
D

AC

R=0

R=0

A
45

IMB14

IMB14

IMB5

IMB5

DIMENSION DRAWINGS

Type of motor

L
L*

IM B14
ExSKg63-.A1
ExSKg63-.A2
ExSKg63-.B1
ExSKg63-.B2
ExSKh71-.A1
ExSKh71-.A2
ExSKh71-.B1
ExSKh71-.B2
ExSKh80-.A1
ExSKh80-.A2
ExSKh80-.B1
ExSKh80-.B2
SKh90S-.
SKh90S-.
SKh90L-.
SKh90L-.

B14C1
B14C2
B14C1
B14C2
B14C1
B14C2
B14C1
B14C2
B14C1
B14C2
B14C1
B14C2
B14C1
B14C2
B14C1
B14C2

GA

LE

120
90
120
90
140
105
140
105
160
120
160
120
160
140
160
140

100
75
100
75
115
85
115
85
130
100
130
100
130
115
130
115

80j6
60j6
80j6
60j6
95j6
70j6
95j6
70j6
110j6
80j6
110j6
80j6
110j6
95j6
110j6
95j6

M6
M5
M6
M5
M8
M6
M8
M6
M8
M6
M8
M6
M8
M8
M8
M8

11j6
11j6
11j6
11j6
14j6
14j6
14j6
14j6
19j6
19j6
19j6
19j6
24j6
24j6
24j6
24j6

23
23
23
23
30
30
30
30
40
40
40
40
50
50
50
50

4h9
4h9
4h9
4h9
5h9
5h9
5h9
5h9
6h9
6h9
6h9
6h9
8h9
8h9
8h9
8h9

12,5
12,5
12,5
12,5
16
16
16
16
21,5
21,5
21,5
21,5
27
27
27
27

14
9,5
14
9,5
14
12
14
12
14
12
14
12
10
10
10
10

3
2,5
3
2,5
3
2,5
3
2,5
3,5
3
3,5
3
3,5
3
3,5
3

Gland

AC

HB

L/L*

M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20

126
126
126
126
141
141
141
141
150
150
150
150
185
185
185
185

114
114
114
114
119
119
119
119
127
127
127
127
130
130
130
130

202/228
202/228
214/240
214/240
223/249
223/249
245/271
245/271
266/283
266/283
278/303
278/303
305/329
305/329
330/354
330354

Bearings
6202 2Z
6202 2Z
6202 2Z
6202 2Z
6203 2Z
6203 2Z
6203 2Z
6203 2Z
6204 2Z
6204 2Z
6204 2Z
6204 2Z
6205 2Z
6205 2Z
6205 2Z
6205 2Z

02/X-EN/2003

Type of motor Flange

07

Cantoni Motor S.A.


Paska 81/83
PL 00-834 Warsaw, Poland
tel. +48 22 652 84 05
fax +48 22 652 84 00
e-mail: motor@cantonimotor.com.pl
http://www.cantonimotor.com.pl

BESEL

since 1950

EMIT

since 1878

since 1954

since 1920

since 1921