Вы находитесь на странице: 1из 16

CABLES AND WIRES

Novi Sad, Republic of Serbia

Sales Centers

SERBIA AND EX-YU Republics NOVKABEL AD Industrijska bb, 21000 Novi Sad, Republic of Serbia Tel: + 381 21 44 23 38 Fax: + 381 21 44 23 40 e-mail: info@novkabel.com www.novkabel.com CENTRAL AND EASTERN EUROPE M POINT KFT F utca 14-18 H-1011 Budapest Hungary Tel: + 361 34 57 810 Fax: + 361 21 25 804 e-mail: mpoint@mpoint.hu RUSSIAN and CIS EPH Office, Moscow Mantulinskaya Street dom 5, str. 3 123100 Moscow Russian Federation Tel: + 7 499 244 06 15/16 Fax: + 7 499 244 08 03 e-mail: info@eph.ru

WESTERN EUROPE East Point Holding Ltd. 31 Evagoras Avenue, 6th (Floor) 1066 Nicosia Cyprus Tel: + 357 22 67 94 90 Fax: + 357 22 67 94 85 e-mail: epoint@eph.point-group.com Romanian Trading Point S.LR. 5,Str. Piata Romana Sector 1, 010671 Bucharest Romania Tel: + 40 21 31 29 612 Fax: + 40 21 31 29 638 e-mail: epoint@rtpoint.ro USA Metalco Corporation 350 Fifth Ave. Suite 5022 Empire State Building NY 10118 New York USA Tel: + 212 239 69 98 Fax: + 212 239 82 81 e-mail: stojan@wptltd.com DP Handel GmbH Westendstrasse 24 D-60325 Frankfurt am Main Germany Tel: + 44 69 97 14 810 Fax: + 44 69 97 14 81 15 e-mail: dp_handel_gmbh@t-online.de EPH Office, Sofia 16, Fr.Jalio Kuriy Str, block 155, 2nd floor, apt 16, Izlak district, 1113 Sofia Bulgaria Tel: + 359 28 17 37 80 Fax: + 359 28 17 31 87 e-mail: bpoint@mbox.con CHINA YU POINT Ltd. Building No. 2-1-11 San Li Tun Diplomatic Compound Chaoyang District, 100600 Beijing PR China Tel: + 86 10 653 21 551 Fax: + 86 10 653 26 955 e-mail: yupoint@netchina.com.cn
CABLES AND WIRES

Company profile
About us
The Cable Factory based in Novi Sad was established in 1921 and is the oldest cable factory in the Balkans. We supply a wide range of energy cables and conductors, telecommunication cables and cables for electronic equipment to suit various industrial needs of construction industry, mining, shipbuilding, as well as oil, transportation, automotive industry and other industries.

Objective
NOVKABEL focuses on quality with utmost respect of the client's needs producing cables in accordance with quality standards and ecology requirements. Our objective is to remain market leader in the production and distribution of all types of cables, improving sales by finding new markets, expanding distribution network and strengthening relationships with business partners.

Capacity
Novkabel production plant occupies an area of almost 40 hectares in the industrial zone of Novi Sad with the production capacity of up to 35.000 tons a year.

NOVKABEL, a member of
Point Group is a leading regional group with subsidiaries and associated companies that operate mainly in South East Europe. The core business activities of the Point Group are: copper processing and trading, wholesale grain trading, mill and bakery industry, river transport and real estate and engineering. The majority of the business operations take place in Serbia, Romania, Hungary and Austria. The Company also has offices in leading world cities: Moscow, New York, Frankfurt and Beijing.

Research and development


From its modest beginnings in the product range with a work of generations of employees on the development of new products, the factory has achieved about 16.000 registered products. NOVKABEL experts dedicate a lot of time to follow and implement the latest technical and technological achievements in cable industry.

Quality
We carry out all quality control procedures to ensure that all raw materials meet intake specifications and follow production until the dispatch of finished products, therefore the investment into control equipment is one of the Novkabel's priorities.

NOVKABEL IS A RECOGNIZABLE PRODUCTION BRAND IN CABLE INDUSTRY OF SOUTHEAST EUROPE BEING A LEADING PROVIDER IN REGARD OF QUALITY AND PRODUCT RANGE.

INSTALLATION PVC INSULATED CONDUCTORS


Type H05V-U H05V-K H07V-U H07V-R H07V-K H03VV-F H03VVH2-F H05VV-F H05VVH2-F Standard DIN VDE 0281/3 DIN VDE 0281/3 DIN VDE 0281/3 DIN VDE 0281/3 DIN VDE 0281/3 DIN VDE 0281/5 DIN VDE 0281/5 DIN VDE 0281/5 DIN VDE 0281/5 DIN VDE 0276/603 Rated voltage 300/500 V 300/500 V 450/750 V 450/750 V 450/750 V 300/300 V 300/300 V 300/500 V 300/500 V PP/J P P/M P/F PP/L For connection of mobile user devices at low mechanical tensile strains. Similar Application Single core non sheated cables are intended for wiring in pipes or raceways, for installations in the dry room, lighting equipment and control instruments. Single core non sheated cables are intended for wiring in pipes or raceways, for installations in the dry room, lighting equipment and control instruments. U wire; R rope; K flexible conductor

For connecting of mobile electrical appliances at low and medium mechanical tensile strains, such as washing machines, vacuum cleaners... In dry and wet conditions indoors and in the open air, for laying on plaster, in plaster or under plaster. Suitable for installations in food industries, laundries and so on. PVC insulated and sheated cable for supply or remote control, at medium mechanical strains. Screened, PVC insulated and sheated cable for supply or remote control, at medium mechanical strains. Oil resistant, PVC insulated and sheated cable for supply or remote control, at medium mechanical strains. Oil resistant, screened, PVC insulated and sheated cable for supply or remote control, at medium mechanical strains.

NYM

300/500 V

PP

SIGNAL CABLES
NYSLY DIN VDE 0245/102 DIN VDE 0245/102 DIN VDE 0281/13 DIN VDE 0281/13 300/500 V

NYSLYCY

300/500 V

H05VV5-F (NYSLY) H05VVC4V5 (NYSLYCY)

300/500 V

300/500 V

POWER CABLES
N(A)YY DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 0,6/1 kV PP00(-A) PVC insulated and sheated cable is used in urban networks and industrial plants, electric power plants and switchgear assemblies. XLPE insulated and PVC sheated cable is used in urban networks and industrial plants, electric power plants and switchgear assemblies. XLPE insulated and PE sheated cable is used in urban networks and industrial plants, electric power plants and switchgear assemblies. PP40(-A) For connection devices where cable is expected to provide electrical protection.

N(A)2XY

0,6/1 kV

XP00(-A)

N(A)Y2Y

0,6/1 kV

N(A)YCY

0,6/1 kV

CABLES AND WIRES

POWER CABLES
Type N(A)YBY Standard DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 Rated voltage 0,6/1 kV Similar PP41(-A) Application
PVC insulated cable is used in urban networks, industrial plants and electric power plants, when mechanical damage could be expected. XLPE insulated cable is used in urban networks, industrial plants and electric power plants, when mechanical damage could be expected.

N(A)2XBY

0,6/1 kV

XP41(-A)

N(A)YRGY

0,6/1 kV

PP44(-A)

N(A)2XRGY

0,6/1 kV

XP44(-A)

For laying when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines for electrical plants, equipments and installations in mines.

N(A)YFGY

0,6/1 kV

PP45(-A)

N(A)2XFGY

0,6/1 kV

XP45(-A)

For laying when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines for electrical plants, equipments and installations in mines.

N(A)YSY

6/10 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV

PHP48(-A)

In distributive lattice, industrial plants and power plants and always when better electrical protection is required.

N(A)2XSY

XHP48(-A)

N(A)2XSEY

For laying indoors, in ducts, directly in earth, in the open air in distribution networks, industrial plants and electric power plants. Laying down directly in the earth is limited by the mechanical properties of the PVC sheath.

N(A)2XS2Y

XHE48(-A)

For laying indoors, in ducts, directly in earth, in the open air in distribution networks, industrial plants and electric power plants.

N(A)2XSE2Y

N(A)2XS(F)2Y

XHE49(-A)

N(A)2XS(FL) 2Y

In distributing network mains, industrial plants, middle-voltage and high voltage switchgear assemblies, thermo-power plants and electric power plants, when cables are exposed to aggresive and wet surrounding effects. For laying indoors, in ducts, in the open air, on cable trays, in earth and in the water. For laying indoors, in ducts, in the open air, directly in earth, in urbane networks, industrial plants and power plants. Suitable for the networks which require minor reduction factor. Not provided for complicated conditions in terms of severe axial strains.

N(A)2XSYBY

XHP81(-A)

N(A)2XSEYB 2Y

XHE81(-A)

POWER CABLES
Type N(A)2XSEY RGbY N(A)2XSEY RGb2Y N(A)2XSEY FGbY N(A)2XSEY FGb2Y Standard DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276 SRPS N.C5.250 GOST R 52373 Rated voltage 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 0,6/1 kV Similar
XHP84(-A)

Application In urban networks, industrial plants and power plants, when the cable is exposed to severe mechanical tensile strains during laying down or use. For laying in ducts, in the open air and in earth.

XHE84(-A)

XHP85(-A)

XHE85(-A)

In urban networks, industrial plants and power plants, when the cable is exposed to severe mechanical tensile strains during laying down or use. For laying in ducts, in the open air and in earth. For distributive low-voltage air networks in urban areas, for air household connections. For distributive low-voltage air networks in urban areas, for air household connections. Self-supporting insulated wires are intended for distributive high-voltage air networks. In the open air for public illumination (lamps carring is possible), for air household connections, site temporary connections, and so on. On pillars, support brackets or steel constructions.

NFA2X

X00-A

0,6/1 kV

X00/O-A

SIP 3

12/20 kV

SRPS N.C3.315

300/500 V

PP/O

RUBBER CABLES
H01N2-D DIN VDE 0282-6 200 V ZN/S Cable is intended for machine and hand welding with very high mechanical stresses. Especially flexible cable is intended for machine and hand welding with very high mechanical stresses. For supplying portable or light mobile appliances with low mechanical stresses (e.g. vacuum cleaners, electric irons, cooking appliances). For supplying portable or light mobile appliances with low mechanical stresses (e.g. vacuum cleaners, electric irons, cooking appliances). EpN 50 It is suitable for connecting electrical appliances and tools, including industrial and agricultural equipment with medium mechanical stresses. Multicore cable is used for connection appliances with medium mechanical stresses. Cable is recomended if torsion stress exists. CABLES AND WIRES

H01N2-E

DIN VDE 0282-6

200 V

H05RR-F

DIN VDE 0282-4

300/500 V

NFK EpG

H05RN-F

DIN VDE 0282-4

300/500 V

H07RN-F

DIN VDE 0282-4 Production Specification of Novkabel

450/750 V

450/750 V

NFK EpN 50

RUBBER CABLES
Type Standard Rated voltage Similar Application Cable is intended for connecting mobile appliances with high mechanical stresses, such as cable reels, lifting equipment, conveyor systems, driven motors, in dry, damp and wet conditions as well as outside.

NSHTu

DIN VDE 0250-814

0,6/1 kV

NFK EpTN

NSSHu

DIN VDE 0250-812 DIN VDE 0250-812 DIN VDE 0250-812 DIN VDE 0250-812 DIN VDE 0250-812 DIN VDE 0250-813 DIN VDE 0250-813 DIN VDE 0250-813

0,6/1 kV

NSSHu /3

0,6/1 kV Rubber flexible cables are intended for the operations in heavy conditions, in surface and methanes pit mines, shipyards, quarries and other type of industry.

NSSHu /3E

0,6/1 kV

EpN 53

NSSCHu NSSCHu KON NTS /3

0,6/1 kV

EpN 55

0,6/1 kV

EpN 63

EpN 78 0,6/1 kV 3,6/6 kV 6/10 kV 12/20 kV 20/35 kV Cables are intended for operating in extremely heavy conditions on surface pit mines, shipyards, quarries and industry. They are suitable for supply of heavy excavators, cranes truck transporters loading bridges and other machines.

NTS /3E

EpN 78/53

NTS KON

EpN 74 Flexible medium voltage cable is intended for operation in mines with underground exploitation, for connecting high voltage movable transformer. Rubber cable is intended for electrical vehicles. Flexible rubber cable is used in electrical vehicles for current circuits for current for heating and control, as well as for lighting. Flexible rubber cable with protective conductor is used in electrical vehicles for current circuits for current for heating and control, as well as for lighting.

SRPS N.C5.364

3,6/6 kV

EpN 65

NSGAu

DIN VDE 0250-602 DIN VDE 0250-602

0,6/1 kV 1,8/3 kV 3,6/6 kV 0,6/1 kV 1,8/3 kV 3,6/6 kV

NSGAFu

NSGAFCMu

DIN VDE 0250-602

3,6/6 kV

BT UIC 895 HT

750 V EpN 1500 V 3000 V

Flexible rubber cable is used in electrical vehicles for current circuits for current for heating and control, as well as for lighting.

RUBBER CABLES
Type Standard DIN VDE 0250-609 Production Specification of Novkabel Production Specification of Novkabel MGG DIN 89159 Rated voltage Similar Application Rubber flexible flat cable is used for connecting mobile parts of the machines, conveyor systems and large machines with medium mechanical stresses and torsion. NFK SiSi/J Silicone flexible flat cable is used for connecting mobile parts of the machines, conveyor systems and large machines as power, signal and control cable. Flexible rubber cable is intended for pumps under water. Rubber insulated cable is intended for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables. Rubber insulated cable with protective conductor is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables. Teledommunication shipboard cable is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as signalling and control cables.

NGFLGu

300/500 V

300/500 V

450/750 V

NFK TES

0,6/1 kV

MGCG

DIN 89158

0,6/1 kV

FMGCG

DIN 89160

250/250 V

HALOGEN FREE CABLES


H05Z-U DIN VDE 0282-9 DIN VDE 0282-9 DIN VDE 0282-9 DIN VDE 0282-9 DIN VDE 0282-9 DIN VDE 0282-13 DIN VDE 0266 DIN VDE 0266 DIN VDE 0266 DIN VDE 0266 300/500 V Halogen free single core non sheated cables with improved characteristics in the case of fire are intended for wiring, for installations in the dry room, lighting equipment and control instruments.

H05Z-K H07Z-U

300/500 V 450/750 V

H07Z- R H07Z-K

450/750 V 450/750 V

Halogen free single core non sheated cables with improved characteristics in the case of fire are intended for wiring in pipes or raceways, for installations in the dry room, lighting equipment and control instruments. These cables are used for connecting electrical appliances and tools, and installations with medium mechanical stresses. Halogen free cables, with concentric conductor (C) or not, are intended for installation in the object where there are rather large requirements for safety of people. These cables, with concentric conductor (C) or not, are particularly suitable for installation which should be functional in the case of the fire (power supply pumps, equipment to extinguish a fire, ventilators for pulling out of smoke, panic lighting, etc). CABLES AND WIRES

H07ZZ-F

450/750 V

NHXHX NHXCHX NHXHX FE180 NHXCHX FE180


6

0,6/1 kV

0,6/1 kV 0,6/1 kV

0,6/1 kV

HALOGEN FREE CABLES


Type LiHXHX Standard Production Specification of Novkabel Production Specification of Novkabel Production Specification of Novkabel Production Specification of Novkabel Production Specification of Novkabel Production Specification of Novkabel DIN VDE 0815 DIN VDE 0815 DIN VDE 0815 DIN VDE 0815 DIN VDE 0250/215 DIN VDE 0250/214 DIN VDE 0276/604 Rated voltage 0,6/1 kV Similar Application Flexible halogen free cables are intended for installation in the object where there are rather large requirements for safety of people. Flexible halogen free cables with concentric conductor are intended for installation in the object where there are rather large requirements for safety of people. These flexible cables, with concentric conductor (C) or not, are particularly suitable for installation which should be functional in the case of the fire (power supply pumps, equipment to extinguish a fire, ventilators for pulling out of smoke, panic lighting, etc). Flexible halogen free cables with improved characteristics in the case of the fire. Flexible halogen free screened cables with improved characteristics in the case of the fire. Installation telecommunication cable for installation line or introducing several lines into buildings. For transmission of analogous and digital signals. For installation in areas with risk of fire. Installation telecommunication cable for installation line or introducing several lines into buildings. For installation line on place where is indispensable to reflect communication in fire long period of time. Also suitable as fire alarm cable. Installation halogen free cables with improved characteristics in the case of the fire. Installation halogen free cables with improved characteristics in the case of the fire. Power halogen free cables with improved characteristics in the case of the fire. Power halogen free and screened cables with improved characteristics in the case of the fire.

LiHXCHX

0,6/1 kV

LiHXHX FE180 LiHXCHX FE180 LiHH LiHCH J-HH J-2Y(St)H

0,6/1 kV

0,6/1 kV

250 V 250 V

300 V 300 V

J-H(St)H

300 V

JE-H(St)H

300 V

NHMH

300/500 V

NHXMH

300/500 V

N2XH

0,6/1 kV

N2XCH

DIN VDE 0276/604 DIN VDE 0276/622 DIN VDE 0276/622

0,6/1 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV

N(A)2XSH

N(A)2XSEH

Halogen free cables is used in distribution networks, industrial plants and electric power plants, when mechanical damage could not be expected.

HALOGEN FREE CABLES


Type Standard DIN VDE 0276/622 Rated voltage 6/10 kV 12/20 kV 20/35 kV Similar Application Halogen free cables is used in urbane networks, industrial plants and power plants, when mechanical damage could be expected. Halogen free cable is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables. Halogen free cable with protective conductor is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables. Screened halogen free cable is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as signalling and control cables

N(A)2XSEHBH

MGH

DIN 89159

0,6/1 kV

MGCH

DIN 89158

0,6/1 kV

FMGCH

DIN 89160

0,6/1 kV

TELECOMMUNICATION CABLES
S-YY DIN VDE 0813 DIN VDE 0813 DIN VDE 0815 DIN VDE 0815 DIN VDE 0815 DIN VDE 0815 DIN VDE 816 DIN VDE 816 For transmission of low-frequency commands in signalling equipment. For transmission of low-frequency commands in signalling equipment. For installation line or introducing several lines into buildings. As leadingin insulated conductor in dry and damp operating area. For installation line or introducing several lines into buildings. Installation cable for permanent connection in industrial electronics. Low-frequency telephone subscriber cable with foam and skin PE insulation is used in local network for subscriber and trunk lines. Low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines. Filled low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines. It is laid in cable ducts or into the ground. Self-supporting low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines. It is laid at supports on the ground walls, rooves. CABLES AND WIRES

S-Y(St)Y

J-YY ... Bd

2YY

J-Y(St)Y

JE-Y(St)Y

A02Y(L)2Y... St III Bd A2Y(L)2Y... St III Bd

A2YF(L)2Y... St III Bd

DIN VDE 816

TK 33 U

PTT, Serbia

TELECOMMUNICATION CABLES
Type TK 39 TP ... M, GM Standard Rated voltage Similar Application Filled low-frequency subscriber cable with solid PE insulation is used in local network for subscriber lines, for direct laying into the ground. Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines, for direct laying into the ground. Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines where the inductive influence of power lines is to be expected. Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines where great influence of power lines is to be expected. Low-frequency cable for network group with foam-skin PE insulation is used in local network for trunk lines. Installation cable for computer networks is used in local networks for data transfer or in networks for automatic control. Self-supporting low-frequency cable is used in network group for trunk lines when there is the inductive influence of power lines. Cable for digital transmission is used in network groups for low-frequency transmission or digital transmission up to 2Mbits/s. Armoured cable for digital transmission is used in network groups for low-frequency transmission or digital transmission up to 2 Mbits/s. It is laid directly into the ground. Symmetrical pair cable for digital transmission (up to 30 MHz), is used in local network for subscriber lines. Flat telephone cord for connector connections are intended for connecting telephones with telephone installation. Control cable for differential protectionvoltage difference measurement or the current at input and output of power equipment. PE insulated cables for the connection of railway station signalsafety units on electrified railwaytracks. PVC insulated cables for the connection of railway station signalsafety units on electrified railwaytracks.
9

PTT, Serbia

TK 59 TP ... M, GM

PTT, Serbia

TK 59 MR, GMR

Production Specification of Novkabel

TK 59 MRL, GMRL

Production Specification of Novkabel DIN VDE 816 DIN VDE 0815 PTT, Serbia

A02Y(L)2Y... St I Bd

J-2Y(St)Y

TD 36 U-P

TD 39 M

PTT, Serbia

TD 59 TP, OP TK 59 DSL (30)

PTT, Serbia

PTT, Serbia

PGA4

PTT Serbia

DP

Production Specification of Novkabel

SEZ

JS, Serbia

SPZ

JS, Serbia

WIRING CONDUCTORS
Type Standard Rated voltage Similar Application

DIN VDE 0815

TM 20

As installation insulated conductor in dry and damp operating area.

YV

DIN VDE 0812

TI 20

As insulated conductor for wiring in telecommunication or data processing devices. Equipment wires (flexible conductor) with insulation of PTFE mass, are intended for wiring of electronic and electric devices where working conditions are demanding high temperatures (up to 250C) Equipment wires (flexible conductor) with insulation of FEP mass, are intended for wiring of all kinds of electronic and medical devices Equipment wires (flexible conductor) with insulation of ETFE mass are intended for automatic or semi-automatic panel connection in computer technics, in telephone centrals and aero industry for wiring of all devices that need high level of mechanical resistance.

(Li)5Y

DIN VDE 0881

(Li)6Y

DIN VDE 0881

(Li)7Y

DIN VDE 0881

CABLES FOR AUDIO SYSTEMS


NAUK 001 NAUK 002 NAUK 003 Production Specification of Novkabel Sub miniature cable is intended for performing internal connections between some points inside audio devices, where screening of audio signal is needed for protection from the disturbance. One- pair audio cables is used in professional audio systems of all kinds. It is intended for production of connecting cables with XLR connectors and transmission of the microphone signal. Multi pair audio cable is being used everywhere where is grouping of the related lines needed for transmission of the signals with optimal usage of the available space. Cable is intended for connection of the technic speaker-phones three- wire asymmetric connection configuration, with movable connecting cables with XLR connectors. Cable are being used for production of flexible connections between power amplifier and loudspeakers in studio monitor systems and professional sound systems. CABLES AND WIRES

NAUK 100

Production Specification of Novkabel

NAUK 200

Production Specification of Novkabel

NAUK 300

Production Specification of Novkabel

NAUK 900

Production Specification of Novkabel

10

ELECTRONIC CABLES
Type Standard Rated voltage Similar Application Flexible cable is intended for connection in measuring, control and regulation technique. It is used for wiring of telecommunication equipment and equipment for data processing too. Flexible screened cable is intended for impulse and data transmission in electronics, computer technics, control, measuring and regulation technics.

LiYY

DIN VDE 0812

250 V

LiYCY

DIN VDE 0812

250 V

OPTICAL FIBER CABLES


OKZPP1 Production Specification of Novkabel Optical fiber cable is suitable for indoor and outdoor aplications. Non- metallic optical fibre cables are specially suitable for the application on relation along with electro- tractive lines, in the areas with common discharging and in the transfer equipment of the electric economy because they are totaly unsensitive for all kinds of electromagnetic influences and atmosphere discharging. Optical fiber cables manufactured according to these technical conditions can be used in local telephone networks as a connecting cables, in long- distance telephone networks as a long- distance cables.

TO SM 03

PTT, Serbia

TO SM 19

PTT, Serbia

COAXIAL CABLES
MIL C-17/28C, MIL C-17/74C Coaxial cable with RG mark and characteristic impedance of 50 , is intended for general usage in professional telecommunication technics and radio amateurism. During the transmission of VF signals through these cables it comes to generating of exceptionally small noise. Coaxial cable with RG mark and characteristic impedance of 75 , is being used in a wide range of commercial electronics and high- frequent technics and everywhere where is transmission of VF signals with less noise transmission needed.

RG 50

RG 75

MIL C-17/78B MIL C-17/77C

UNINSULATED CONDUCTORS
Aluminium conductors, steel reinforced Hard copper and bronze stranded conductors DIN 48 204 Conductors for overhead power lines.

DIN 48 201

Conductors for overhead power lines.

11

UNINSULATED CONDUCTORS
Type Aluminum conductors Standard DIN VDE 0295 class 2 Rated voltage Similar Application For the cable industry.

Round stranded DIN VDE conductors 0295 copper class 1,2,5,6 (bare or tinned) DIN VDE 0295 class 2

For the cable industry.

Aluminum wires

For use in cable industry and for other products like rivets, ect.

Copper wires (bare or tinned)

DIN VDE 0295 class 1,2,5,6

In cable industry, for elektrotechnical and other products.

DIN VDE 0295; Profiled stranded NF C 32-321; conductors SRPS of copper N.C0.015 and aluminum class 2 Very flexible flat braid DIN 46444

For the cable industry.

They are used for connections with earth connections in electronics and in automobile industry for brushes in electromotors. They are used for the grounding of the electrical units, and in the automobile industry.

Flat braid

DIN 72 333

Very flexible braid

Production Specification of Novkabel

For partial screening and similar applications in electronics.

Stranded conductors with overall copper braid

DIN 46440

They are used for connections with earth connections in electronics and in automobile industry for brushes in electromotors. For use in sparc erosion units which use wire as electrode. Using MCV wire enable faster cutting up to 30%.

Wire for Production erosimat zinc Specification plated copper of Novkabel wire (MCV) Brass wire MS 63 SRPS C.D1.120

For sieves, and other products of general purposes.

12

CABLES AND WIRES

Certificate

member of

Novkabel AD Industrijska bb, 21000 Novi Sad, Republic of Serbia Tel: + 381 21 44 23 38 Fax: + 381 21 44 23 40 e-mail: info@novkabel.com www.novkabel.com Point Group Francuska 6, 11000 Belegrade, Republic of Serbia Tel: + 381 11 33 46 444 Fax: +381 11 32 34 431 e-mail: yupb@eph.point-group.com www.point-group.com