Compact Design Hydraulic Cylinder 160S-1

Compact Design Hydraulic Cylinder

21

160S-1

16MPa Compact Design Hydraulic Cylinder

16MPa Compact Design Hydraulic Cylinder with Steel Body


Operates up to 10 million times at maximum 16 MPa. Abrasion resistant seal is standard. Standard type cylinders are fully operable at ambient temperatures of up to 120C.

Introducing special copper alloy for vital hydraulic cylinder. Sliding type switches allow flexible switch placement.

Standard Specifications
Types Specifications of General Purpose Cutting Fluid Proof Types

Terminologies (Referred to the revised JIS B8367)


Nominal pressure
Pressure to be used to express a cylinder models typical performance. This pressure value does not always match the actual operating pressure (rated pressure) at which the cylinders performance is ensured under the specified conditions.

Compact Design Hydraulic Cylinder

Nominal pressure Maximum operating pressure Proof test pressure Minimum working pressure Operationg speed range Temperature range (Ambient temperature and oil temperature) Structure of cushioning Adaptable working oil Tolerance of thread Tolerance of stroke Mounting type Rod end threads Suitable switches for switch set 160S-1R:

16 MPa 16 MPa 24MPa 0.3 MPa 8 - 100 mm/s Standard type ..................................... -10 - +120C Switch set AX AZ type ............... -10 - +70C (Note) WR WS type ............ -10 - +60C (free of freeze) None Petroleum-based fluid (For other working oil, refer to the table of working oil adaptability) JIS 6 g/6H (JIS grade 2 or equivalence) 0 to 0.8mm SD, ST, LA, LD, FA, FB SD, LD, FA, FB

Maximum operating pressure


The cylinders maximum internal pressure available. This pressure differs from the relief valves set pressure. Pressures that are higher than the relief valves set pressure, such as surge pressure during valve changing, are applied to the inside of the cylinder.

Proof test pressure


Proof test pressure is defined what could keep performance of cylinder through test pressure and nominal pressure.

Minimum working pressure


The minimum pressure that the cylinder placed horizontally without a load can work. Notes) This cylinder is not equipped with an air bleeder.
Since

lateral load (eccentric load) cannot be applied to the piston rod, carefully adjust it after rod end attachment. working temperature range depends on the material of packings. For details, refer to the selection materials in the beginning of this catalogue. the piston touches the cylinder end at the stroke end, decelerate the cylinder to a speed lower than the minimum operating speed.

Female and male threads AX AZ types WR WS types 160SW-1R: WR WS types

The

Note) The switch AX125 and AZ125 are newly developed for high temperature circumstance up to 100C.

If

Cutting fluid proof models


These models can be used in environments where the machine tool cutting oil (coolant) can be splashed. Sealing materials suitable for each cutting oil are as shown in the right side table:

Allowable Seal Material (Hydrogenated Nitrile Rubber) and Cutting Oil


Non-water Soluble Cutting Oil Water Soluble Cutting Oil Type 1 K K: All wable Type 2

: Unallowable

16MPa Compact Design Hydraulic Cylinder

160S-1
Unit: mm

22

Lines
Structure Type Mounting Type 20 SD (ST)
Standard type

25

32

40

50

63

80

100

125

160S-1

LA LD, FA, FB SD (ST)

General purpose type

Double Acting Single Rod

Switch set

160S-1R

LA LD, FA, FB SD

Standard type

Double Acting Double Rod

160S-1D

LA LD, FA

Switch set

SD LD, FA SD LD, FA, FB SD LD, FA, FB SD LD, FA SD LD, FA


Compact Design Hydraulic Cylinder

160S-1RD
Standard type

Cutting fluid proof type

Double Acting Single Rod

160SW-1
Switch set

160SW-1R
Standard type

Double Acting Double Rod

160SW-1D
Switch set

160SW-1RD

Notes)

Switches cant be mounted on Standard type. You are requested to select Switch set type when you would like to use switches. The ST mounting type is a made-to-order product.

Standard type
Basic type (SD)

Switch set

Basic type

160SW-1R

160SW-1RD

Foot type 160S-1R 160S-1RD

Double acting single-rod (160S-1, 160SW-1)

Double acting double-rod (160S-1D, 160SW-1D)

Double acting single-rod (160S-1R, 160SW-1R)

Double acting double-rod (160S-1RD, 160SW-1RD)

Cylinder dimensions are all the same for both general purpose and cutting fluid proof types.

23

160S-1
General purpose type
s1 rie Se

16MPa Compact Design Hydraulic Cylinder

Dotted lines for types and symbols are not written when unnecessary.
ty pe 3 pe 5 ia l2 e4 er or ty

Semi-standard components
Ai rv en t ! 2

Standard type Switch set

160S-1 160S-1R

6 6

SD SD

40 40

N N

50 50

T T

Standard type 160S-1 : Double acting single-rod 160S-1D : Double acting double-rod Switch set 160S-1R : Double acting single-rod 160S-1RD : Double acting double-rod 6 Hydrogenated nitrile rubber (standard) 3 Fluoric rubber (semi-standard) Note) The seal of bore size 20mm & 25mm is only Nitrile rubber for high temperature.

Compact Design Hydraulic Cylinder

Thread holes mounting LA type, foot type Foot type Head flange mounting Cap flange mounting Note) LD,FA mounting style cylinders consist of SD cylinder and each bracket. In this case, SD cylinders Standard type SD : 20 - 125 ST : 32 - 80 LD, FA, FB : 20 - 80 LA : 32 - 63 Switch set SD, ST, LD, FA, FB : 32 - 80 LA : 32 - 63

SD ST LA LD FA FB

SD type, basic type

Female thread (no symbol for the standard type) T Male thread Note) Double-rod and male thread means both sides are male thread as standard. Cylinder stroke (mm) Without cushion

Cutting fluid proof type


Standard type Switch set

R160SW-1 160SW-1R

6 SD 6 SD

40 40

N N

50 50

Standard type 160SW-1 : Double acting single-rod 160SW-1D : Double acting double-rod Switch set 160SW-1R : Double-acting single rod 160SW-1RD : Double-acting double rod Note) For explanations for models other than the above, refer to the general purpose type models. ST, LA is not available.

5 8

5F WR525F (cord extended from the rear, with 5 m cord/flex tube attached) Cylinder bore (mm) 32 - 100 8F WR535F (cord extended from the top, with 5 m cord/flex tube attached) Note) 100mm bore is not available for RA AX205W (cord extended from the rear, with 5 m cord) LD, FA, FB. RB AZ205W (cord extended from the top, with 5 m cord) 2 1 Hydrogenated nitrile rubber
WS235 (cord extended from the rear, with 5 m cord) WS245 (cord extended from the top, with 5 m cord)

2F WS235F (cord extended from the rear, with 5 m cord/flex tube attached) 1F WS245F (cord extended from the top, with 5 m cord/flex tube attached)

St ro ke 6 re ad Po rt ty sp pe ec 7 ifi ca tio Sw n8 itc h sy m bo Sw l9 itc hq ua nti ty ! 0 Lo ck nu t! 1 Th

m at

rb de C

in g

nt

ck in g

in

ou

Pa

yl

us

hi

on

G G AF 2

L L

V V

None Without air vent (Standard) With air vent (Made-toV


order:bore 32mm to 125mm) with one lock nut Note) Available only for male thread type Additional order is required when 2 or more lock nuts are necessary. Switch quantity (1 or 2) Switch symbol Note) Select applicable switches out of the Switch List. Notes on order for switch sets If a switch is unnecessary, enter the switch symbol o and the switch quantity !0 of 0. When ordering a switch set, switches are not mounted to cylinders at delivery.

None Rc thread G thread G


Note) G screw is only for SD Mounting.

T T

G G 5

L 2 L

V V

WR525 (cord extended from the rear, with 5 m cord) WR535 (cord extended from the top, with 5 m cord)

16MPa Compact Design Hydraulic Cylinder

160S-1
Applicable Wiring Method Cord Length Load Device

24

Switch List
Kind Switch Symbol Load Voltage Range Load Current Range AF AX101 AG AX105 AH AX111 AJ AX115 AE AX125 AK AX11A AL AX11B 5 Contact WR525 5F WR525F AP AZ101 AR AZ105 AS AZ111 AT AZ115 AN AZ125 AU AZ11A AW AZ11B 8 WR535 8F WR535F BE AX201 BF AX205 CE AX211 CF AX215 No Contact 2 WS235-1 2F WS235-1F BM AZ201 BN AZ205 CM AZ211 CN AZ215 Cutting fluid RA AX205W proof type RB AZ205W No Contact 1 WS245-1 1F WS245-1F CT AX211CE CU AX215CE No Contact CV AX21BCE CE DC:5 - 30 V coformed CW AZ211CE CX AZ215CE DC:10 - 30 V 6 - 20mA Present DC:5 - 30 V 5 - 40mA Present DC:10 - 30 V 6 - 20mA Present DC:5 - 30 V 5 - 40mA Present
DC:30V or less DC:40mA or less AC:120V or less AC:20mA or less DC:30V or less DC:40mA or less AC:120V or less AC:20mA or less Maximum Open/ Close Capacity

Protective Circuit Indicating Lamp None

1.5m LED (Red light lights 0.3 mm2, 2-core, up during ON) outer dia. 4 mm rear wiring None LED (Red light lights up during ON) LED (Red light lights up during ON) 5m 1.5m 5m 5m 4-pin connector type, rear wiring 0.3 mm2, 2-core, outer dia. 4 mm rear wiring 0.5m 0.5m 5m 5m 1.5m LED (Red light lights 0.3 mm2, 2-core, up during ON) outer dia. 4 mm upper wiring None LED (Red light lights up during ON) LED (Red light lights up during ON) LED (Red light lights up during ON) LED (2-lamp type in red/green) LED (2-lamp type in red/green) LED (Red light lights up during ON) LED (2-lamp type in red/green) LED (Red light lights up during ON) LED (2-lamp type in red/green) 5m 1.5m 5m 5m 4-pin connector type, upper wiring 0.3 mm2, 2-core, outer dia. 4 mm upper wiring 0.5m 0.5m 5m 5m 1.5m 5m 0.3 mm2, 2-core, 1.5m outer dia. 4 mm 5m rear wiring 5m 5m 1.5m 0.3 mm2, 2-core, outer dia. 4 mm upper wiring
0.3 mm2, 2-core, outer dia. 4 mm rear wiring 0.3 mm2, 2-core, outer dia. 4 mm upper wiring

DC:5 - 30 V DC:5 - 40mA AC:5 - 120 V AC:5 - 20mA

DC:1.5W AC:2VA

Present None

AC:5 - 120 V DC:5 - 30 V

5 - 20mA 5 - 40mA

2VA 1.5W DC:1.5W AC:2VA

Present None None

DC:5 - 50 V DC:3 - 40mA AC:5 - 120 V AC:3 - 20mA

Small relay, programmable controller

DC:5 - 30 V DC:5 - 40mA AC:5 - 120 V AC:5 - 20mA

DC : 1.5W AC : 2VA

Present None

AC:5 - 120 V DC:5 - 30 V

5 - 20mA 5 - 40mA

2VA 1.5W DC : 1.5W AC : 2VA

Present None

DC:5 - 50 V DC:3 - 40mA AC:5 - 120 V AC:3 - 20mA

Compact Design Hydraulic Cylinder

5m 1.5m 5m 5m Small relay, programmable controller

5m 0.3 mm2, 2-core, 5m outer dia. 4 mm 5m upper wiring 0.3 mm2, 2-core, 1.5m outer dia. 4 mm 5m rear wiring

5 - 40mA

Present

LED 4-pin connector type, 0.5m rear wiring (2-lamp type in 0.3 mm2, 2-core, 1.5m red/green) outer dia. 4 mm 5m upper wiring
4-pin connector type, upper wiring

CY AZ21BCE

0.5m

Notes)

For the switches without a protective circuit, be sure to provide the protective circuit (SK-100) with load devices when using induction load devices (relay, etc.). For the handling of switches, be sure to refer to the switch specifications in the end of this catalogue. The WR and WS type switches are cutting fluid proof type. We recommend AND UNIT (AU series) for multiple switches connected in series.

For the switch symbol o, pay attention to the points below when ordering the cutting fluid proof type switches, WR and WS types.

General purpose type


AX type (cord rear wiring)

Cutting fluid proof type


WR WS type switch
Cord

rear wiring

5 8 2 1 5F 8F 2F 1F

WR525 WR535 WS235-1 WS245-1

The switch and straight box connector (F-SB) are combined [the flex tube (F-05: 4.8 m) is required].

WR525 WS235-1 AZ type (cord upper wiring)


Cord

WR525F The flex tube (F-05: 4.8 m) is attached to WR535F the switch and straight box connector WS235-1F (F-SB). WS245-1F

upper wiring

WR535 WS245-1

Switch body

Straight box connector: F-SB Flex tube: F-05

25

160S-1
Structure Type Mounting Type Bore f20 f25 f32 f40 Basic type f50 (SD) f63 f80 f100 f125 Standard f20 Flange type f25 type 160S-1 f32 (FA, FB) f40 General f50 Foot type purpose f63 (LD) type f80 f32 f40 Foot type (LA) f50 f63 Basic type f32 (SD) f40 Flange type f50 (FA, FB) f63 Foot type Switch set (LD) f80 160S-1R f32 Foot type f40 (LA) f50 f63 f32 f40 Basic type f50 (SD) f63 Standard f80 type f100 160SW-1 f32 Flange Cutting type f40 fluid (FA, FB) f50 proof type Foot type f63 (LD) f80 Basic type f32 (SD) f40 Switch set Flange type f50 (FA, FB) 160SW-1R f63 Foot type (LD) f80 : Standard manufacturing range,

16MPa Compact Design Hydraulic Cylinder

Standard stroke fabrication range (Single-rod)


5 10 15 20 25 30 Cylinder Stroke (mm) 35 40 45 50 60 70 80 90 100
Male Thread Type

Compact Design Hydraulic Cylinder

: Range available for manufacturing for order

Available bore range at ST mounting. (Single-rod only/Made-to-order)


Structure Type Mounting Type Thread holes mounting (ST) Thread holes mounting (ST) Bore f32 f40 f50 f63 f80 f32 f40 f50 f63 f80 110 120 130 140 Cylinder Stroke (mm) 150 160 170 180 190 200
Male Thread Type

General purpose type

Standard type 160S-1

Switch set 160S-1R

: Range available for manufacturing for order

16MPa Compact Design Hydraulic Cylinder

160S-1
70 80 90 100 Type
Male Thread

26

Standard stroke fabrication range (Double-rod)


Structure Type Mounting Type Bore f20 f25 f32 f40 f50 f63 f80 f100 f125 f20 f25 f32 f40 f50 f63 f80 f32 f40 f50 f63 f32 f40 f50 f63 f80 f32 f40 f50 f63 f80 f100 f32 f40 f50 f63 f80 f32 f40 f50 f63 f80 : Range available for manufacturing for order 5 10 15 20 25 30 Cylinder Stroke (mm) 35 40 45 50 60

Basic type (SD)

Standard type 160S-1D General purpose type

Flange type (FA) Foot type (LD)

Foot type (LA) Basic type (SD) Switch set Flange type (FA) 160S-1RD Foot type (LD)

Compact Design Hydraulic Cylinder

Basic type (SD) Standard type 160SW-1D

Cutting fluid proof type

Flange type (FA) Foot type (LD)

Basic type (SD) Switch set Flange type (FA) 160SW-1RD Foot type (LD) : Standard manufacturing range,

27

160S-1
Packing Material
cFluoric rubber nHydrogenated nitrile rubber

16MPa Compact Design Hydraulic Cylinder

Adaptability of Working Oil to Packing Material


Adaptable Working Oil
Petroleum- Water-glycol Phosphoric W/O Water in based fulid fulid ester fluid oil fluid O/W Oil in water fluid

Cutting Fluid Proof Type/Adaptability of Cutting Fluid to Packing Material


Packing Material
nHydrogenated nitrile rubber

Non-water Soluble Cutting Oil Type 1 K Type 2 Water Soluble Cutting Oil K

K : applicable : inapplicable

Notes) 1. The and K - marked items are applicable, while the - marked items are inapplicable. 2. The - marked items are the recommended packing materials in case of giving the first priority to abrasion resistance.

Specification of Air Vent (Option)


The air vents are laid on the port surface and located symmetrical position to the port.
Set screw (Exclusive use for air vent) Steel ball 2-Port (Figure) 2-Air vent

How to order G screw piping port (only for SD type)


Please specify the model as following. ex. 160S-1 6SD63N30 G G screw piping port Note) In some bores, the apparent dimensions are changed from their standard when you specify G screw. Please refer to the detailed dimension table in following pages.

(Structure): Single-rod, Double-rod SD/LD/FA/FB type

Location of air vent on the same surface as piping port (Option)

Dimension Table
Bore Part Model

Compact Design Hydraulic Cylinder

How to order only lock nut


d

d M101.25 M121.25 M161.5 M201.5 M241.5 M301.5 M391.5 M481.5 M642

B 17 19 22 27 32 41 55 70 90

C 19.6 21.9 25.4 31.2 37.0 47.3 68.5 80.8 104

h 6 7 10 12 14 17 20 26 35

20 25 32 40
C

LNH-10F-H LNH-12F-H LNH-16F-H LNH-20F-H LNH-24F-H LNH-30F-H LNH-39F-H LNH-48F-H LNH-64F-H

50 63 80 100 125

Switch Mounting Minimum Possible Stroke


With A Switch Bore AX and AZ types WR type WS type AX and AZ types WR type WS type With Two Switches

32 40 50 63 80
Note) When attaching two switches of the WR or WS type, they cannot be attached to the same surface. (WR and WS type switches are not available for LA mounting.) If you would like to mount two switches to 10mm stroke cylinder, please.

10

10

10

20

Operating Ranges and Differences


Contact Bore AX and AZ types WR type AX and AZ types No Contact AX205WAZ205W WS type

Operating range Difference Operating range Difference Operating range Difference Operating range Difference Operating range Difference 32 40 15 - 22 50 63 80 19 - 25 10 - 17 2 or less 10 - 17 2 or less 4-8 1 or less 2 or less 15 - 24 1 or less

16MPa Compact Design Hydraulic Cylinder

160S-1
Unit: kg
Mounting accessories Rod end attachment additional weight additional weight

28

Weight Table/General Purpose and Cutting Fluid Proof Types


Basic type (SD) Foot type (LA) Separate Bore Double Acting Single-rod Double Acting Double-rod Double Acting Single-rod Double Acting Double-rod flange Foot type Flange type (mm) joint Basic Added weight Basic Added weight Basic Added weight Basic Added weight (LD) (FA, FB) for each for each for each for each (M type weight stroke of 1 mm weight stroke of 1 mm weight stroke of 1 mm weight stroke of 1 mm joint)

Added male thread weight

20 25 32 40 50 63 80 100 125

0.6 0.8 1.4 1.8 2.5 3.8 6.6 12.5 21.5

0.013 0.016 0.025 0.030 0.037 0.047 0.067 0.102 0.152

0.7 1.0 1.6 2.1 2.7 4.1 7.6 14.9 29

0.014 0.017 0.024 0.032 0.036 0.041 0.083 0.121 0.222

1.4 1.8 2.6 4.1

0.027 0.034 0.044 0.062

1.9 2.4 3.3 5.0

0.028 0.036 0.048 0.068

0.25 0.30 0.62 1.16 1.60 2.02 3.77

0.46 0.58 1.09 1.42 2.43 3.30 5.86

0.2 0.3 0.3 0.4 0.6 0.8 1.4 3.0 5.3

0.015 0.026 0.057 0.114 0.201 0.435 0.798


Unit: kg

Weight Table/Switch set


Basic type (SD) Bore (mm) Double Acting Single-rod Basic weight Added weight for each stroke of 1 mm Double Acting Double-rod Basic weight Added weight for each stroke of 1 mm Foot type (LA) Double Acting Single-rod Basic weight Added weight for each stroke of 1 mm Flange type (FA, FB) Foot type (LD)
Mounting accessories additional weight Rod end attachment additional weight

Separate flange joint (M type joint)

Added male thread weight

Compact Design Hydraulic Cylinder

32 40 50 63 80

1.2 1.6 2.2 3.3 6.2

0.022 0.028 0.036 0.049 0.071

1.3 1.7 2.4 3.7 7.2

0.024 0.031 0.041 0.057 0.084

1.2 1.6 2.3 3.6

0.022 0.028 0.036 0.049

0.62 1.16 1.60 2.02 3.77

1.09 1.42 2.43 3.30 5.86

0.3 0.4 0.6 0.8 1.4

0.057 0.114 0.201 0.435 0.798

Switch Added Weight Table


AX AZ Type Cord length 1.5 m Cord length 5 m Connector type

Unit: kg WR WS Type

0.05

0.13

0.04

0.50

Formula Cylinder weight (kg) = Basic weight + (Cylinder stroke (mm) Added weight for each stroke of 1 mm) + (Added switch weight Number of switches) Calculation example 160S-1R: Bore of 40, cylinder stroke of 50 mm, AZ101 (cord length of 1.5 m), with two switches 1.6 + (50 0.028) + (0.05 2) = 3.10 kg

Piston Pressurized Area Table


Bore (mm) Rod Diameter (mm) Double Acting Single-rod Push side Pull side Push side

Unit: mm2 Double Acting Double-rod Pull side Formula F = AP(N) F: Cylinder force (N) A: Piston pressurized area (mm2) P: Applied pressure (MPa) : Load rate Calculation example Double acting single-rod, bore of 40, applied pressure of 16 MPa, load rate of 0.8 Push side cylinder force (N) = 1257 16 0.8 = 16090 (N) Pull side cylinder force (N) = 876 16 0.8 = 11213 (N)

20 25 32 40 50 63 80 100 125

12 14 18 22 28 36 45 56 70

314 491 804 1257 1963 3117 5027 7854 12272

201 337 550 876 1348 2100 3436 5391 8424

201 337 550 876 1348 2100 3436 5391 8424

29

160S-1
SD

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1

6 SD Bore N Stroke

T T

(20 - 125) (32 - 100)


None : Female thread T : Male thread

Cutting fluid proof type 160SW-1 6 SD Bore N Stroke

Bore 20, 25
Less than 15 strokes EE WF C Over 15 strokes EE

Male thread
A KK

MM

Width across flats D 4-FB holes 24-Counter hole diameter FG, Depth BT Y KK depth KL

PJ+ Stroke PL EE

PJ+ Stroke

PL

Compact Design Hydraulic Cylinder

MM Width across flats D C TV E WF LL+Stroke LF+Stroke

MM Width across flats D WF

C LL+Stroke LF+Stroke

Bore 32 - 125
Male thread
A WF C EE

G screw port
DE FF KK

AE

MM Width across flats D

N N

4-FB holes 24-Counter hole diameter FG, Depth BT

Y KK depth KL

PJ+Stroke

PL

MM

Width across flats D C TV E WF LL+Stroke LF+Stroke

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm

160S-1
FG 9.5 9.5 11 14 17.5 20 23 29 35 M81.25 M101.5 M121.75 M162 M202.5 M273 M303.5 M394 M485 KK Female thread Male thread KL M101.25 M121.25 M161.5 M201.5 M241.5 M301.5 M391.5 M481.5 M642 Y Rc thread G thread 30 36 47 52 58 69 86 106 132 8 8 10 10 11 13 17 26 30 20.5 20.5 28 27 28 30 35 42 46 28 27 28 30 36 42 46 10 12 15 20 24 33 36 45 58

30

Dimension Table
Symbol A
Bore

AE 8 8 12 12 12 12 14

BT 5.4 5.4 6.5 8.6 10.8 13 15.2 19.5 23.5

C 6 6 7 7 8 9 14 22 25 N

D 10 12 14 19 24 30 41 50 65

DE 17.2 17.2 21.5 21.5 21.5 25.5 30

E 44 50 62 70 80 94 114 140 172 PJ

EE Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8 Rc3/8 Rc1/2

FB 5.5 5.5 6.6 9 11 14 16 20 24

FF G1/8 G1/8 G1/4 G1/4 G1/4 G3/8 G1/2 PL

20 15(25) 25 18(30) 32 25(40) 40 30(45) 50 35(50) 63 45(60) 80 60(80) 100 75(95) 125 95(125) Symbol LF
Bore

LL 43 45 54 55 60 67 78 96 105

MM 12 14 18 22 28 36 45 56 70 10 10 10 10 15 15 25

TV 12 12 18.5 17 18 28 30

WF

Rc thread G thread Rc thread G thread Rc thread G thread 51 53 64 65 71 80 95 122 135 10 10 14 16 19 18 25 10.5 12.5 14 16 19 24 25 26 29 14 16 13.5 20 24 26 29 12 12 12 12 13 13 18 28 30

20 25 32 40 50 63 80 100 125 Notes)

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

31

160S-1
ST

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm

General purpose type 160S-1 6 ST Bore N Stroke

(32 - 80/Made-to-order)
None : Female thread T : Male thread

over 101 strokes (110, 120, 130, 140, 150, 160, 170, 180, 190, 200)

Bore 32 - 80
Male thread A WF C EE

KK

MM

N N

Compact Design Hydraulic Cylinder

Width across flats D Y PJ Y

24-TT, Deapth BT

KK depth KL

MM

Width across flats D TV E C WF LL

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm

160S-1
MM 18 22 28 36 45 N 10 10 10 10 15 TT M61 M81.25 M101.5 M121.75 M162 PJ TV 47 52 58 69 86 WF 10 10 11 13 17 Y 28 27 28 30 35

32

Dimension Table
Symbol A
Bore

KK BT 15 20 25 30 35 C 7 7 8 9 14 D 14 19 24 30 41 E 62 70 80 94 114 LL 110 192 192 195 202 215 120 202 202 205 212 225 130 212 212 215 222 235 140 222 222 225 232 245 150 232 232 235 242 255 160 242 242 245 252 265 170 252 252 255 262 275 180 262 262 265 272 285 190 272 272 275 282 295 200 282 282 285 292 305 110 136 138 139 142 145 120 146 148 149 152 155 130 156 158 159 162 165 140 166 168 169 172 175 EE Female thread Male thread Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8 M121.75 M162 M202.5 M273 M303.5 M161.5 M201.5 M241.5 M301.5 M391.5 15 20 24 33 36 KL

32 40 50 63 80
Symbol Stroke

25(40) 30(45) 35(50) 45(60) 60(80)

Bore

150 176 178 179 182 185

160 186 188 189 192 195

170 196 198 199 202 205

180 206 208 209 212 215

190 216 218 219 222 225

200 226 228 229 232 235

32 40 50 63 80

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Compact Design Hydraulic Cylinder

33

160S-1
LA

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1 6 LA Bore N Stroke

(32 - 63)
None : Female thread T : Male thread

Bore 32 - 63

Male thread
A C KK WF

4-GB holes 4-Counter hole diameter FG, Depth BT

SY

SG+Stroke SW 2-EE

MM

N N

Width across flats D

Compact Design Hydraulic Cylinder

EA TS KK depth KL

PJ+ Stroke

PL

EB LH

MM

C Width across flats D T WF TX TW

TZ+ Stroke

LL+Stroke LF+Stroke

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm

160S-1
KK KL Male thread M161.5 M201.5 M241.5 M301.5 15 20 24 33 64 65 71 80 25 0.06 29 0.06 34 0.06 42 0.06 LF LH

34

Dimension Table
Symbol A
Bore

BT 8.6 10.8 13 15.2

C 7 7 8 9

D 14 19 24 30

EA 70 80 94 114

EB 56 64 74 89

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4

FG 14 17.5 20 23

GB 9 11 14 16 M121.75 M162 M202.5 M273

Female thread

32 40 50 63 Symbol

25(40) 30(45) 35(50) 45(60)

LL
Bore

MM 18 22 28 36

N 10 10 10 10

PJ 14 16 19 24

PL 12 12 13 13

SG 24 23 27 32

SW 10 12 13 15

SY 20 20 20 20

T 63 70 80 100

TS 56 62 74 90

TW 12 12 14 16

TX 28 28 29 31

TZ 14 15 17 20

WF 10 10 11 13

Y 28 27 28 30

32 40 50 63

54 55 60 67

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Compact Design Hydraulic Cylinder

Recommended Key Way Dimensions

When using a parallel key:

b1

Parallel key attached to the cylinder


r1 r1 t1

When not using a parallel key:


Pulling stopper Pushing stopper

Dimension Table
Bore
Keys Nominal Dimensions bh1 12863 (Both rounded) 12870 (Both rounded) 14980 (Both rounded) 1610100 (Both rounded) Key Way Dimensions

Use the same dimensions for the stopper as the attached parallel key.

b1
0 12 0.043 0 12 0.043 0 14 0.043 0 16 0.043

t1 5 +0.2 0 5 +0.2 0 5.5 +0.2 0 6 +0.2 0

r1

32 40 50 63

0.25 - 0.40

When using the foot type, use the attached parallel key to install the cylinder, referring to the Recommended Key Way Dimensions. When not using the parallel key, attach the stoppers to the cylinders front and rear sides toward its stroke direction. If the cylinder is used without using the key or stoppers, a large force is applied to the cylinders mounting bolts, possibly resulting in the fracturing of the bolts.

35

160S-1
LD

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1

6 LD Bore N Stroke

T T

(20 - 80) (32 - 80)


None : Female thread T : Male thread

Cutting fluid proof type 160SW-1 6 LD Bore N Stroke

Bore 20, 25

Male thread
A KK W C

Less than 15 strokes


EE

Over 15 strokes
EE

MM Width across flats D

FP E KK depth KL

PJ+ Stroke LF+Stroke

PK

FP

PJ+ Stroke LF+Stroke

PK

EE

Compact Design Hydraulic Cylinder

EH LH ST

MM Width across flats D TS US

MM Width across flats D LL+Stroke SS+Stroke ZB+Stroke SU SY

C W SU XS

C W SU XS LL+Stroke SS+Stroke ZB+Stroke SU SY

4-SB

Bore 32 - 80
Male thread
A KK W C

EE

N MM N Width across flats D

FP E KK depth KL

PJ+Stroke

PK

LF+Stroke

EH LH ST

MM

Width across flats D C 4-SB TS US W XS SU LL+Stroke SS+Stroke ZB+Stroke SU SY

*Please be sure to use the Socket Head Screw when install the cylinder to the contact patch.

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm

160S-1
KL Male thread M101.25 M121.25 M161.5 M201.5 M241.5 M301.5 M391.5 10 12 15 20 24 33 36 73 75 94 95 110 117 138 24 0.15 27 0.15 35 0.15 37.5 0.15 45 0.15 50 0.15 60 0.25 LF LH

36

Dimension Table
Symbol A
Bore

C 6 6 7 7 8 9 14

D 10 12 14 19 24 30 41

E 44 50 62 70 80 94 114

EE Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

EH 46 52 66 72.5 85 97 117

FP 35.5 35.5 48 47 53 55 65

KK Female thread M81.25 M101.5 M121.75 M162 M202.5 M273 M303.5

20 25 32 40 50 63 80 Symbol

15(25) 18(30) 25(40) 30(45) 35(50) 45(60) 60(80)

LL
Bore

MM 12 14 18 22 28 36 45

N 10 10 10 10 15

PJ 10.5 12.5 14 16 19 24 25

PK 27 27 32 32 38 38 48

SB 6.6 6.6 9 11 14 16 18

SS 58 60 74 75 85 92 108

ST 12 12 16 20 24 30 35

SU 15 15 20 20 25 25 30

SY 7.5 7.5 10 10 12.5 12.5 15

TS 58 64 79 90 104 121 144

US 70 76 94 108 126 146 172

W 8 8 10 10 11 13 17

XS 15.5 15.5 20 20 23.5 25.5 32

ZB 81 83 104 105 121 130 155

20 25 32 40 50 63 80 Notes)

43 45 54 55 60 67 78

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

37

160S-1
FA

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1

6 FA Bore N Stroke

T T

(20 - 80) (32 - 80)


None : Female thread T : Male thread

Cutting fluid proof type 160SW-1 6 FA Bore N Stroke

Bore 20, 25
Less than 15 strokes EE Over 15 strokes EE

Male thread
A KK W C

MM

Width across flats D Y KK depth KL PJ+ Stroke PL Y PJ+ Stroke PL

E TV

Compact Design Hydraulic Cylinder

EE

FE R

MM Width across flats D TF UF

4-M

MM

4-M

4-FB

C W F LL+Stroke LF+Stroke

Width across flats D

C W F LL+Stroke LF+Stroke

Bore 32 - 80
EE

Male thread
A KK C N N MM Width across flats D W

E TV KK depth KL

PJ+Stroke

PL

FE R

MM 4-M Width across flats D C

4-FB

TF UF

LL+Stroke LF+Stroke

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm

160S-1
KK KL Male thread M101.25 M121.25 M161.5 M201.5 M241.5 M301.5 M391.5 10 12 15 20 24 33 36 61 63 79 85 91 100 120 LF

38

Dimension Table
Symbol A
Bore

C 6 6 7 7 8 9 14

D 10 12 14 19 24 30 41

E 44 50 62 70 80 94 114

EE Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

F 10 10 15 20 20 20 25

FB 5.5 5.5 6.6 11 14 14 18

FE 46 52 62 70 85 98 118 M81.25 M101.5 M121.75 M162 M202.5 M273 M303.5

Female thread

20 25 32 40 50 63 80 Symbol

15(25) 18(30) 25(40) 30(45) 35(50) 45(60) 60(80)

LL
Bore

M M5 0.8 M5 0.8 M6 1 M8 1.25 M10 1.5 M12 1.75 M14 2

MM 12 14 18 22 28 36 45

N 10 10 10 10 15

PJ 10.5 12.5 14 16 19 24 25

PL 12 12 12 12 13 13 18

R 30 36 40 46 58 65 87

TF 60 66 80 96 108 124 154

TV 30 36 47 52 58 69 86

UF 75 80 95 118 135 150 185

W 8 8 10 10 11 13 17

Y 20.5 20.5 28 27 28 30 35

20 25 32 40 50 63 80 Notes)

43 45 54 55 60 67 78

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

39

160S-1
FB

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1

6 FB Bore N Stroke

T T

(20 - 80) (32 - 80)


None : Female thread T : Male thread

Cutting fluid proof type 160SW-1 6 FB Bore N Stroke

Bore 20, 25
Male thread
A KK C WF Less than 15 strokes EE Over 15 strokes EE

MM

Width across flats D Y KK depth KL 4-M EE 4-M PJ+ Stroke PL Y PJ+ Stroke PL

E TV

Compact Design Hydraulic Cylinder

FE R

MM Width across flats D

MM

4-FB TF UF

C WF LL+Stroke LF+Stroke F

Width across flats D

C WF LL+Stroke LF+Stroke F

Bore 32 - 80

Male thread
A KK C N N WF

EE

Width across flats D

E TV KK depth KL

PJ+Stroke

PL

4-M

FE R

MM Width across flats D C

4-FB

TF UF

WF

LL+Stroke LF+Stroke

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Standard Type Unit: mm

160S-1
KK KL Male thread M101.25 M121.25 M161.5 M201.5 M241.5 M301.5 M391.5 10 12 15 20 24 33 36 61 63 79 85 91 100 120 LF

40

Dimension Table
Symbol A
Bore

C 6 6 7 7 8 9 14

D 10 12 14 19 24 30 41

E 44 50 62 70 80 94 114

EE Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

F 10 10 15 20 20 20 25

FB f5.5 f5.5 f6.6 f11 f14 f14 f18

FE 46 52 62 70 85 98 118 M81.25 M101.5 M121.75 M162 M202.5 M273 M303.5

Female thread

20 25 32 40 50 63 80 Symbol

15(25) 18(30) 25(40) 30(45) 35(50) 45(60) 60(80)

LL
Bore

M M5 0.8 M5 0.8 M6 1 M8 1.25 M10 1.5 M12 1.75 M14 2

MM f12 f14 f18 f22 f28 f36 f45

N 10 10 10 10 15

PJ 10.5 12.5 14 16 19 24 25

PL 12 12 12 12 13 13 18

R 30 36 40 46 58 65 87

TF 60 66 80 96 108 124 154

TV 30 36 47 52 58 69 86

UF 75 80 95 118 135 150 185

WF 8 8 10 10 11 13 17

Y 20.5 20.5 28 27 28 30 35

20 25 32 40 50 63 80 Notes)

43 45 54 55 60 67 78

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

41

160S-1
SD

16MPa Compact Design Hydraulic Cylinder Double Acting Double-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1D Cutting fluid proof type 160SW-1D

6 SD Bore N Stroke 6 SD Bore N Stroke

T T

(20 - 125) (32 - 100)


None : Female thread T : Male thread

Bore 20, 25
Less than 15 strokes EE KK depth KL Over 15 strokes EE KK depth KL

Male thread
A KK C WF

MM

Width across flats D Y 4-FB holes 24-Counter hole diameter FG, Depth BT KK depth KL PJ+ Stroke Y EE V cut machined circle V cut machined circle Y PJ+ Stroke Y

Compact Design Hydraulic Cylinder

TV E

MM Width across flats D C WF

MM MM Width across flats D C WF+ Stroke WF

MM

LL+Stroke

LL+Stroke

WF+ Stroke

Bore 32 - 125
EE

Male thread G screw port


DE FF KK A C WF

KK depth KL
N N

AE

Width across flats D

4-FB holes 24-Counter hole diameter FG, Depth BT KK depth KL

PJ+Stroke

V cut machined circle

MM

MM

Width across flats D


C TV E WF

LL+Stroke

WF+Stroke

Face with no V cut machined circle is for mounting.

16MPa Compact Design Hydraulic Cylinder Unit: mm Double Acting Double-rod/Standard Type

160S-1
FG 9.5 9.5 11 14 17.5 20 23 29 35 Y M81.25 M101.5 M121.75 M162 M202.5 M273 M303.5 M394 M485 KK Female thread Male thread KL 10 12 15 20 24 33 36 45 58

42

Dimension Table
Symbol A
Bore

AE 8 8 12 12 12 12 14

BT 5.4 5.4 6.5 8.6 10.8 13 15.2 19.5 23.5 N

C 6 6 7 7 8 9 14 22 25

D 10 12 14 19 24 30 41 50 65

DE 17.2 17.2 21.5 21.5 21.5 25.5 30 PJ

E 44 50 62 70 80 94 114 140 172

EE Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8 Rc3/8 Rc1/2

FB 5.5 5.5 6.6 9 11 14 16 20 24

FF G1/8 G1/8 G1/4 G1/4 G1/4 G3/8 G1/2

20 15(25) 25 18(30) 32 25(40) 40 30(45) 50 35(50) 63 45(60) 80 60(80) 100 75(95) 125 95(125) Symbol LL
Bore

M101.25 M121.25 M161.5 M201.5 M241.5 M301.5 M391.5 M481.5 M642

MM 12 14 18 22 28 36 45 56 70 10 10 10 10 15 15 25

TV 16 18 19 22 23 24 28 30 36 47 52 58 69 86 106 132

WF 8 8 10 10 11 13 17 26 30 20.5 20.5 28 27 28 30 35 42 46

Rc thread G thread Rc thread G thread 54 56 72 72 75 82 95 108 120 10 10 14 16 19 18 25 13 15 16 18 19 22 25 24 28

Rc thread G thread 28 27 28 30 36 42 46

20 25 32 40 50 63 80 100 125 Notes)

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

43

160S-1
LA

16MPa Compact Design Hydraulic Cylinder Double Acting Double-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1D

6 LA Bore N Stroke

(32 - 63)

None : Female thread T : Male thread

Bore 32 - 63
4-GB holes 4-Counter hole diameter FG, Depth BT WF C KK N N KK depth KL SV+Stroke

SY

SY

Male thread
A

2-EE

MM Width across flats D

EA TS

Y KK depth KL

PJ+Stroke

Compact Design Hydraulic Cylinder

V cut machined circle

EB LH

MM

MM

Width across flats D T

C TX WF TW TZ+Stroke LJ+Stroke WF+Stroke

16MPa Compact Design Hydraulic Cylinder Unit: mm Double Acting Double-rod/Standard Type

160S-1
GB 9 11 14 16 M121.75 M162 M202.5 M273 KK Female thread Male thread M161.5 M201.5 M241.5 M301.5 15 20 24 33 KL

44

Dimension Table
Symbol A
Bore

BT 8.6 10.8 13 15.2

C 7 7 8 9

D 14 19 24 30

EA 70 80 94 114

EB 56 64 74 89

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4

FG 14 17.5 20 23

32 40 50 63 Symbol

25(40) 30(45) 35(50) 45(60)

LH
Bore

LJ 72 72 75 82

MM 18 22 28 36

N 10 10 10 10

PJ 16 18 19 22

SV 32 32 35 42

SY 20 20 20 20

T 63 70 80 100

TS 56 62 74 90

TW 12 12 14 16

TX 28 28 29 31

TZ 32 32 32 35

WF 10 10 11 13

Y 28 27 28 30

32 40 50 63

25 0.06 29 0.06 34 0.06 42 0.06

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Compact Design Hydraulic Cylinder

Recommended Key Way Dimensions

When using a parallel key:

b1

Parallel key attached to the cylinder


r1 r1 t1

When not using a parallel key:


Pulling stopper Pushing stopper

Dimension Table
Bore
Keys Nominal Dimensions bh1 12863 (Both rounded) 12870 (Both rounded) 14980 (Both rounded) 1610100 (Both rounded) Key Way Dimensions

Use the same dimensions for the stopper as the attached parallel key.

b1
0 12 0.043 0 12 0.043 0 14 0.043 0 16 0.043

t1 5 +0.2 0 5 +0.2 0 5.5 +0.2 0 6 +0.2 0

r1

32 40 50 63

0.25 - 0.40

When using the foot type, use the attached parallel key to install the cylinder, referring to the Recommended Key Way Dimensions. When not using the parallel key, attach the stoppers to the cylinders front and rear sides toward its stroke direction. If the cylinder is used without using the key or stoppers, a large force is applied to the cylinders mounting bolts, possibly resulting in the fracturing of the bolts.

45

160S-1
LD

16MPa Compact Design Hydraulic Cylinder Double Acting Double-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1D Cutting fluid proof type 160SW-1D

6 LD Bore N Stroke 6 LD Bore N Stroke

T T

(20 - 80) (32 - 80)


None : Female thread T : Male thread

Bore 20, 25
Male thread
KK A W C

Less than 15 strokes


EE KK depth KL

Over 15 strokes
EE KK depth KL

MM Width across flats D PJ+ Stroke PJ+ Stroke

FP E KK depth KP

FP EE

FP

FP

EH

MM LH ST TS US Width across flats D C W SU XS LZ+Stroke SV+Stroke ZZ+Stroke2

MM

MM

MM

Compact Design Hydraulic Cylinder

4-SB

W+ SU Stroke XS+Stroke

Width across flats D C C W SU XS LZ+Stroke SV+Stroke ZZ+Stroke2

W+ SU Stroke XS+Stroke

Bore 32 - 80
Male thread
A KK W C KK depth KL N MM N Width across flats D EE

FP E KK depth KL

PJ+Stroke LG+Stroke

FP

EH LH ST

MM

MM

Width across flats D TS US

C W XS SU LZ+Stroke SV+Stroke ZZ+Stroke2 SU W+Stroke XS+Stroke

4-SB

*Please be sure to use the Socket Head Screw when install the cylinder to the contact patch.

16MPa Compact Design Hydraulic Cylinder Unit: mm Double Acting Double-rod/Standard Type

160S-1
KL M101.25 M121.25 M161.5 M201.5 M241.5 M301.5 M391.5 10 12 15 20 24 33 36 LG 84 86 112 112 125 132 155 LH 24 0.15 27 0.15 35 0.15 37.5 0.15 45 0.15 50 0.15 60 0.25 Male thread

46

Dimension Table
Symbol A
Bore

C 6 6 7 7 8 9 14

D 10 12 14 19 24 30 41

E 44 50 62 70 80 94 114

EE Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

EH 46 52 66 72.5 85 97 117

FP 33.5 35.5 48 47 53 55 65

KK Female thread M81.25 M101.5 M121.75 M162 M202.5 M273 M303.5

20 25 32 40 50 63 80 Symbol

15(25) 18(30) 25(40) 30(45) 35(50) 45(60) 60(80)

LZ
Bore

MM 12 14 18 22 28 36 45

N 10 10 10 10 15

PJ 13 15 16 18 19 22 25

SB 6.6 6.6 9 11 14 16 18

ST 12 12 16 20 24 30 35

SU 15 15 20 20 25 25 30

SV 69 71 92 92 100 107 125

TS 58 64 79 90 104 121 144

US 70 76 94 108 126 146 172

W 8 8 10 10 11 13 17

XS

ZZ

20 25 32 40 50 63 80 Notes)

54 56 72 72 75 82 95

15.5 100 15.5 102 20 20 132 132

23.5 147 25.5 158 32 189

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

47

160S-1
FA

16MPa Compact Design Hydraulic Cylinder Double Acting Double-rod/Standard Type Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1D Cutting fluid proof type 160SW-1D

6 FA Bore N Stroke 6 FA Bore N Stroke

T T

(20 - 80) (32 - 80)


None : Female thread T : Male thread

Bore 20, 25
Less than 15 strokes
EE KK depth KL

Male thread
A KK C W(WF)

Over 15 strokes
EE KK depth KL

MM

Width across flats D E TV Y KK depth KL 4-M 4-M PJ+ Stroke Y Y PJ+ Stroke Y

Compact Design Hydraulic Cylinder

FE R

MM Width across flats D TF UF W

MM

MM

MM

Width across flats D C F LL+Stroke WF+Stroke W

4-FB

C F LL+Stroke WF+Stroke

Bore 32 - 80
Male thread
A KK MM Width across flats D W(WF) C KK depth KL N N EE

E TV KK depth KL

PJ+Stroke

4-M

FE R

MM Width across flats D C

MM

4-FB

TF UF

LL+Stroke

WF+Stroke

16MPa Compact Design Hydraulic Cylinder Unit: mm Double Acting Double-rod/Standard Type

160S-1
KK Female thread Male thread M101.25 M121.25 M161.5 M201.5 M241.5 M301.5 M391.5 10 12 15 20 24 33 36 KL

48

Dimension Table
Symbol A
Bore

C 6 6 7 7 8 9 14

D 10 12 14 19 24 30 41

E 44 50 62 70 80 94 114

EE Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

F 10 10 15 20 20 20 25

FB 5.5 5.5 6.6 11 14 14 18

FE 46 52 62 70 85 98 118 M81.25 M101.5 M121.75 M162 M202.5 M273 M303.5

20 25 32 40 50 63 80 Symbol

15(25) 18(30) 25(40) 30(45) 35(50) 45(60) 60(80)

LL
Bore

M M50.8 M50.8 M61 M81.25 M101.25 M121.75 M142

MM 12 14 18 22 28 36 45

N 10 10 10 10 15

PJ 13 15 16 18 19 22 25

R 30 36 40 46 58 65 87

TF 60 66 80 96 108 124 154

TV 30 36 47 52 58 69 86

UF 75 80 95 118 135 150 185

W 8 8 10 10 11 13 17

WF 8 8 10 10 11 13 17

Y 20.5 20.5 28 27 28 30 35

20 25 32 40 50 63 80 Notes)

54 56 72 72 75 82 95

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

49

160S-1
SD

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1R Cutting fluid proof type 160SW-1R

6 SD Bore N Stroke 6 SD Bore N Stroke

T T

Switch symbol Switch symbol


: Female thread T : Male thread

Quantity of Switch Quantity of Switch

Bore 32 - 80
Male thread G screw port
DE FF MM Width across flats D KK A C WF EE

AE

N N

PJ+Stroke

PL

Cord extended to rear 4-FB holes AX type


RV

24-Counter hole diameter FG, Depth BT

Cord extended to top AZ type


RV KK depth KL UX1 UX2

Compact Design Hydraulic Cylinder

MM Width across flats D C TV E WF LL+Stroke

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

160S-1
FG 11 14 17.5 20 23 M12 1.75 M16 2 M20 2.5 M27 3 M30 3.5 KK Female thread Male thread KL M16 1.5 M20 1.5 M24 1.5 M30 1.5 M39 1.5 Y Rc thread G thread 28 27 28 30 35 28 27 28 30 36 15 20 24 33 36

50

General purpose type Dimension Table


Symbol A
Bore

AE 8 8 12 12 12

BT 6.5 8.6 10.8 13 15.2 N

C 7 7 8 9 14

D 14 19 24 30 41

DE 17.2 17.2 21.5 21.5 21.5 PJ

E 62 70 80 94 114

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8 PL

FB 6.6 9 11 14 16 RV

FF G1/8 G1/8 G1/4 G1/4 G1/4

32 40 50 63 80 Symbol

25(40) 30(45) 35(50) 45(60) 60(80)

LL
Bore

MM 18 22 28 36 45

TV 44 48 53 60 70 47 52 58 69 86

UX1 19 20 22 24 30

UX2 WF 17 17 20 25 30 10 10 11 13 17

Rc thread G thread Rc thread G thread Rc thread G thread AX type AZ type 10 10 10 10 15 10 10 14 16 19 14 16 19 24 25 14 16 13.5 20 24 12 12 13 13 18 12 12 18.5 17 18 37 41 46 53 63

32 40 50 63 80 Notes)

54 55 60 67 78

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

Cutting fluid proof type

Dimension Table
RV RY UX1 WS 15 20 21 24 29 UX2 AX205W WR AZ205W 11 11 14 18 22 12 14 16 21 25 WS 16 16 20 23 29
R2 5o rm

Bore Cord rear wiring Cord upper wiring Cord rear wiring Cord upper wiring AX205W WR AX205W WRWS AZ205W WRWS AX205W WRWS AZ205W WRWS AZ205W 32 40 50 63 80 37 41 46 54 63 53 57 62 69 79 44 48 53 61 70 53 57 62 69 79 74 82 92 108 126 106 114 124 138 158 88 96 106 122 140 106 114 124 138 158 13 14 16 17 22 11 17 19 20 25

ore

Recessed for the bend radius dimension.

When the switch cannot be attached as shown above, use the other type (cord upper wiring).

Note) Set the flex tube so that its bend radius becomes R25 or more. If the bend radius becomes smaller than this value, the cord may be disconnected.

Switch attachment dimensions


Cord rear wiring WR525 (contact) AX205W (no contact)
RY RV RV RV

Cord upper wiring WR535 (contact) AZ205W (no contact)


RY RV RV RV RV

WS235-1 (no contact)


RY

WS245-1 (no contact)


RY RV

51

160S-1
ST

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

General purpose type 160S-1R 6 ST Bore N Stroke

Switch symbol Quantity of Switch (32-80/Made-to-order)

: Female thread T : Male thread over 101 strokes (110, 120, 130, 140, 150, 160, 170, 180, 190, 200)

Bore 32 - 80
Male thread
A KK WF C

EE

MM

N N

Width across flats D

Compact Design Hydraulic Cylinder

Cord extended to rear AX type


RV 24-TT, Deapth BT

Cord extended to top AZ type


RV KK depth KL

PJ

UX1

UX2

MM Width across flats D

C TV WF E LL

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

160S-1
RV TT TV UX1 UX2 WF 47 29 52 30 58 32 69 34 86 40 35 34 35 40 47 10 10 11 13 17 Y 28 27 28 30 35

52

Dimension Table
Symbol A
Bore

KK BT C 7 7 8 9 14 D 14 19 24 30 41 E 62 70 80 94 EE Female thread Male thread Rc1/4 M12 1.75 M16 1.5 15 18 10 Rc1/4 M16 2 Rc1/4 M20 2.5 Rc1/4 M27 3 M20 1.5 20 22 10 M24 1.5 24 28 10 M30 1.5 33 36 10 M39 1.5 36 45 15 KL MM N

AX type AZ type 37 41 46 53 63 44 M61 48 M81.25 53 M101.5 60 M121.75 70 M162 PJ

32 25(40) 15 40 30(45) 20 50 35(50) 25 63 45(60) 30 80 60(80) 35


Symbol Stroke

114 Rc3/8 M30 3.5 LL

Bore

110 192 192 195 202 215

120 202 202 205 212 225

130 212 212 215 222 235

140 222 222 225 232 245

150 232 232 235 242 255

160 242 242 245 252 265

170 252 252 255 262 275

180 262 262 265 272 285

190 272 272 275 282 295

200 282 282 285 292 305

110 136 138 139 142 145

120 146 148 149 152 155

130 156 158 159 162 165

140 166 168 169 172 175

150 176 178 179 182 185

160 186 188 189 192 195

170 196 198 199 202 205

180 206 208 209 212 215

190 216 218 219 222 225

200 226 228 229 232 235

32 40 50 63 80

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Compact Design Hydraulic Cylinder

53

160S-1
LA

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

General purpose type 160S-1R

6 LA Bore N Stroke

Switch symbol

Quantity of Switch

: Female thread T : Male thread

Bore 32 - 63
Male thread
A C KK 4-GB holes 4-Counter hole diameter FG, Depth BT WF UX1 UX2

MM Width across flats D

SE

SG+Stroke

SF

EA

Compact Design Hydraulic Cylinder

TS KK depth KL

PJ+Stroke

PL

RV EB LH

MM

N N

C T Width across flats D WF TX TW TZ+Stroke LJ+Stroke 2-EE

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

160S-1
KK KL LH 25 0.06 29 0.06 34 0.06 42 0.06 LJ 72 72 75 82 MM 18 22 28 36

54

Dimension Table
Symbol A
Bore

BT 8.6 10.8 13 15.2

C 7 7 8 9

D 14 19 24 30

EA 70 80 94 114

EB 56 64 74 89

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4

FG 14 17.5 20 23

GB Female thread Male thread 9 11 M121.75 M162 M161.5 M201.5 M241.5 M301.5

32 40 50 63 Symbol

25(40) 30(45) 35(50) 45(60)

15 20 24 33

14 M202.5 16 M273

N
Bore

PJ 16 18 15 18

PL 28 27 30 32

RV 62 70 80 95

SE 13 13 13 15

SF 13 13 13 15

SG 46 46 49 52

T 63 70 80 100

TS 56 62 74 90

TW 12 12 14 16

TX 28 28 29 31

TZ 32 32 32 35

UX1 19 20 22 24

UX2 35 34 35 40

WF 10 10 11 13

Y 28 27 30 32

32 40 50 63

8 10 10 10

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Compact Design Hydraulic Cylinder

Recommended Key Way Dimensions

When using a parallel key:

b1

Parallel key attached to the cylinder


r1 r1 t1

When not using a parallel key:

Pulling stopper

Pushing stopper

Dimension Table
Bore
Keys Nominal Dimensions bh1 12863 (Both rounded) 12870 (Both rounded) 14980 (Both rounded) 1610100 (Both rounded) Key Way Dimensions

Use the same dimensions for the stopper as the attached parallel key.

b1
0 12 0.043 0 12 0.043 0 14 0.043 0 16 0.043

t1 5 +0.2 0 5 +0.2 0 5.5 +0.2 0 6 +0.2 0

r1

32 40 50 63

0.25 - 0.40

When using the foot type, use the attached parallel key to install the cylinder, referring to the Recommended Key Way Dimensions. When not using the parallel key, attach the stoppers to the cylinders front and rear sides toward its stroke direction. If the cylinder is used without using the key or stoppers, a large force is applied to the cylinders mounting bolts, possibly resulting in the fracturing of the bolts.

55

160S-1
LD

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1R Cutting fluid proof type 160SW-1R

6 LD Bore N Stroke 6 LD Bore N Stroke

T T

Switch symbol Switch symbol


: Female thread T : Male thread

Quantity of Switch Quantity of Switch

Bore 32 - 80
Male thread
A KK W C EE

N MM N Width across flats D

Compact Design Hydraulic Cylinder

FP RV E KK depth KL UX1

PJ+Stroke LF+Stroke UX2

PK

EH LH ST

MM

Width across flats D W TS

C SU XS LL+Stroke SS+Stroke ZB+Stroke SU SY

4-SB

US

*Please be sure to use the Socket Head Screw when install the cylinder to the contact patch.

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

160S-1
KL LF 94 95 110 117 138 LH 35 0.15 37.5 0.15 45 0.15 50 0.15 60 0.25 LL 54 55 60 67 78

56

General purpose type Dimension Table


Symbol A
Bore

C 7 7 8 9 14

D 14 19 24 30 41

E 62 70 80 94 114

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8 RV

EH 66 72.5 85 97 117

FP 48 47 53 55 65 M121.75 M162 M202.5 M273 M303.5

KK Female thread Male thread M161.5 M201.5 M241.5 M301.5 M391.5

32 40 50 63 80 Symbol

25(40) 30(45) 35(50) 45(60) 60(80)

15 20 24 33 36

MM
Bore

N 10 10 10 10 15

PJ 14 16 19 24 25

PK 32 32 38 38 48 37 41 46 53 63

SB 44 48 53 60 70 9 11 14 16 18

SS 74 75 85 92 108

ST 16 20 24 30 35

SU 20 20 25 25 30

SY 10 10 12.5 12.5 15

TS 79 90 104 121 144

US 94 108 126 146 172

UX1 19 20 22 24 30

UX2 17 17 20 25 30

W 10 10 11 13 17

XS 20 20

ZB 104 105

AX type AZ type f18 f22 f28 f36 f45

f32 f40 f50 f63 f80

23.5 121 25.5 130 32 155

Compact Design Hydraulic Cylinder

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Cutting fluid proof type

Dimension Table
RV RY UX1 WS 15 20 21 24 29 UX2 AX205W WR AZ205W 11 11 14 18 22 12 14 16 21 25 WS 16 16 20 23 29
R2 5o rm

Bore Cord rear wiring Cord upper wiring Cord rear wiring Cord upper wiring AX205W WR AX205W WRWS AZ205W WRWS AX205W WRWS AZ205W WRWS AZ205W 32 40 50 63 80 37 41 46 54 63 53 57 62 69 79 44 48 53 61 70 53 57 62 69 79 74 82 92 108 126 106 114 124 138 158 88 96 106 122 140 106 114 124 138 158 13 14 16 17 22 11 17 19 20 25

ore

Recessed for the bend radius dimension.

When the switch cannot be attached as shown above, use the other type (cord upper wiring).

Note) Set the flex tube so that its bend radius becomes R25 or more. If the bend radius becomes smaller than this value, the cord may be disconnected.

Switch attachment dimensions


Cord rear wiring WR525 (contact) AX205W (no contact)
RY RV RV RV

Cord upper wiring WR535 (contact) AZ205W (no contact)


RY RV RV RV RV

WS235-1 (no contact)


RY

WS245-1 (no contact)


RY RV

57

160S-1
FA

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1R Cutting fluid proof type 160SW-1R

6 FA Bore N Stroke 6 FA Bore N Stroke

T T

Switch symbol Switch symbol


: Female thread T : Male thread

Quantity of Switch Quantity of Switch

Bore 32 - 80
Male thread
A C KK W

EE

MM Width across flats D

N N

Y E TV RV

PJ+Stroke

PL

Compact Design Hydraulic Cylinder

KK depth KL

UX1

UX2

FE R

MM 4-M Width across flats D C

4-FB

TF UF

LL+Stroke LF+Stroke

*Please be sure to use the Socket Head Screw when install the cylinder to the contact patch.

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

160S-1
KL LF 79 85 91 100 120 LL 54 55 60 67 78 M M6 1 M8 1.25 M10 1.5 M12 1.75 M14 2

58

General purpose type Dimension Table


Symbol A
Bore

C 7 7 8 9 14

D 14 19 24 30 41

E 62 70 80 94 114

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

F 15 20 20 20 25

FB 6.6 11 14 14 18

FE 62 70 85 98 118 RV M12 1.75 M16 2 M20 2.5 M27 3 M30 3.5

KK Female thread Male thread M16 1.5 M20 1.5 M24 1.5 M30 1.5 M39 1.5

32 40 50 63 80 Symbol

25(40) 30(45) 35(50) 45(60) 60(80)

15 20 24 33 36

MM
Bore

N 10 10 10 10 15

PJ 14 16 19 24 25

PL 12 12 13 13 18

R 40 46 58 65 87 37 41 46 53 63

AX type AZ type 18 22 28 36 45 44 48 53 60 70

TF 80 96 108 124 154

TV 47 52 58 69 86

UF 95 118 135 150 185

UX1 19 20 22 24 30

UX2 17 17 20 25 30

W 10 10 11 13 17

Y 28 27 28 30 35

32 40 50 63 80 Notes)

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

Cutting fluid proof type

Dimension Table
RV RY UX1 WS 15 20 21 24 29 UX2 AX205W WR AZ205W 11 11 14 18 22 12 14 16 21 25 WS 16 16 20 23 29
R2 5o rm

Bore Cord rear wiring Cord upper wiring Cord rear wiring Cord upper wiring AX205W WR AX205W WRWS AZ205W WRWS AX205W WRWS AZ205W WRWS AZ205W 32 40 50 63 80 37 41 46 54 63 53 57 62 69 79 44 48 53 61 70 53 57 62 69 79 74 82 92 108 126 106 114 124 138 158 88 96 106 122 140 106 114 124 138 158 13 14 16 17 22 11 17 19 20 25

ore

Recessed for the bend radius dimension.

When the switch cannot be attached as shown above, use the other type (cord upper wiring).

Note) Set the flex tube so that its bend radius becomes R25 or more. If the bend radius becomes smaller than this value, the cord may be disconnected.

Switch attachment dimensions


Cord rear wiring WR525 (contact) AX205W (no contact)
RY RV RV RV

Cord upper wiring WR535 (contact) AZ205W (no contact)


RY RV RV RV RV

WS235-1 (no contact)


RY

WS245-1 (no contact)


RY RV

59

160S-1
FB

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1R Cutting fluid proof type 160SW-1R

6 FB Bore N Stroke 6 FB Bore N Stroke

T T

Switch symbol Switch symbol


: Female thread T : Male thread

Quantity of Switch Quantity of Switch

Bore 32 - 80
Male thread
A C KK WF EE

MM Width across flats D

N N

Y E

PJ+Stroke

PL

Compact Design Hydraulic Cylinder

TV RV

KK depth KL UX1 4-M

UX2

FE R

MM Width across flats D C

4-FB

TF UF

WF

LL+Stroke LF+Stroke

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

160S-1
KL M161.5 M201.5 M241.5 M301.5 M391.5 15 20 24 33 36 LF 79 85 91 100 120 LL 54 55 60 67 78 M M6 1 M8 1.25 M10 1.5 M12 1.75 M14 2

60

General purpose type Dimension Table


Symbol A
Bore

C 7 7 8 9 14

D 14 19 24 30 41

E 62 70 80 94 114

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

F 15 20 20 20 25

FB 6.6 11 14 14 18 RV

FE 62 70 85 98 118 M121.75 M162 M202.5 M273 M303.5

KK Female thread Male thread

32 40 50 63 80 Symbol

25(40) 30(45) 35(50) 45(60) 60(80)

MM
Bore

N 10 10 10 10 15

PJ 14 16 19 24 25

PL 12 12 13 13 18

R 40 46 58 65 87 37 41 46 53 63

TF 44 48 53 60 70 80 96 108 124 154

TV 47 52 58 69 86

AX type AZ type 18 22 28 36 45

UF 95 118 135 150 185

UX1 19 20 22 24 30

UX2 17 17 20 25 30

WF 10 10 11 13 17

Y 28 27 28 30 35

32 40 50 63 80 Notes)

Compact Design Hydraulic Cylinder

When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. 20mm and 25mm bore size of Cutting Fluid Proof Type are not available. Allowance of MM is f8.

Cutting fluid proof type

Dimension Table
RV RY UX1 WS 15 20 21 24 29 UX2 AX205W WR AZ205W 11 11 14 18 22 12 14 16 21 25 WS 16 16 20 23 29
R2 5o rm

Bore Cord rear wiring Cord upper wiring Cord rear wiring Cord upper wiring AX205W WR AX205W WRWS AZ205W WRWS AX205W WRWS AZ205W WRWS AZ205W 32 40 50 63 80 37 41 46 54 63 53 57 62 69 79 44 48 53 61 70 53 57 62 69 79 74 82 92 108 126 106 114 124 138 158 88 96 106 122 140 106 114 124 138 158 13 14 16 17 22 11 17 19 20 25

ore

Recessed for the bend radius dimension.

When the switch cannot be attached as shown above, use the other type (cord upper wiring).

Note) Set the flex tube so that its bend radius becomes R25 or more. If the bend radius becomes smaller than this value, the cord may be disconnected.

Switch attachment dimensions


Cord rear wiring WR525 (contact) AX205W (no contact)
RY RV RV RV

Cord upper wiring WR535 (contact) AZ205W(no contact)


RY RV RV RV RV

WS235-1 (no contact)


RY

WS245-1 (no contact)


RY RV

61

160S-1
SD

16MPa Compact Design Hydraulic Cylinder Double Acting Double-rod/Switch set Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1RD Cutting fluid proof type 160SW-1RD

6 SD Bore N Stroke 6 SD Bore N Stroke

T T

Switch symbol Switch symbol


: Female thread T : Male thread

Quantity of Switch Quantity of Switch

Bore 32 - 80
Male thread G screw port
DE FF MM Width across flats D KK A C KK depth KL AE N N WF

EE

PJ+Stroke

Compact Design Hydraulic Cylinder

Cord extended to rear AX type


RV

Cord extended to top AZ type


RV KK depth KL UX1 UX2 V cut machined circle

MM Width across flats D 4-FB holes 24-Counter hole diameter FG, Depth BT C TV E WF LL+Stroke WF+Stroke

MM

16MPa Compact Design Hydraulic Cylinder Double Acting Double-rod/Switch set Unit: mm

160S-1
KK FG Female thread Male thread 11 14 17.5 20 23 M121.75 M162 M202.5 M273 M303.5 Y Rc thread G thread 28 27 28 30 35 28 27 28 30 36 M161.5 M201.5 M241.5 M301.5 M391.5 KL 15 20 24 33 36

62

General purpose type Dimension Table


Symbol A
Bore

AE 8 8 12 12 12

BT 6.5 8.6 10.8 13 15.2 N

C 7 7 8 9 14

D 14 19 24 30 41

DE 17.2 17.2 21.5 21.5 21.5 PJ

E 62 70 80 94 114 RV

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

FB 6.6 9 11 14 16

FF G1/8 G1/8 G1/4 G1/4 G1/4

32 40 50 63 80 Symbol

25(40) 30(45) 35(50) 45(60) 60(80)

LL
Bore

MM 18 22 28 36 45

Rc thread G thread Rc thread G thread AX type AZ type 10 10 10 10 15 10 10 14 16 19 16 18 19 22 25 14 16 13.5 20 24 37 41 46 53 63 44 48 53 60 70

TV 47 52 58 69 86

UX1 19 20 22 24 30

UX2 WF 35 34 35 40 47 10 10 11 13 17

32 40 50 63 80

72 72 75 82 95

Compact Design Hydraulic Cylinder

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Cutting fluid proof type

Dimension Table
RV RY UX1 WS 15 20 21 24 29 UX2 AX205W WR AZ205W 11 11 14 18 22 28 33 35 36 43 WS 32 36 37 40 47
R2 5o rm

Bore Cord rear wiring Cord upper wiring Cord rear wiring Cord upper wiring AX205W WR AX205W WRWS AZ205W WRWS AX205W WRWS AZ205W WRWS AZ205W 32 40 50 63 80 37 41 46 54 63 53 57 62 69 79 44 48 53 61 70 53 57 62 69 79 74 82 92 108 126 106 114 124 138 158 88 96 106 122 140 106 114 124 138 158 13 14 16 17 22 11 17 19 20 25

ore

Recessed for the bend radius dimension.

When the switch cannot be attached as shown above, use the other type (cord upper wiring).

Note) Set the flex tube so that its bend radius becomes R25 or more. If the bend radius becomes smaller than this value, the cord may be disconnected.

Switch attachment dimensions


Cord rear wiring WR525 (contact) AX205W (no contact)
RY RV RV RV

Cord upper wiring WR535 (contact) AZ205W (no contact)


RY RV RV RV RV

WS235-1 (no contact)


RY

WS245-1 (no contact)


RY RV

63

160S-1
LD

16MPa Compact Design Hydraulic Cylinder Double Acting Double-rod/Switch set Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1RD Cutting fluid proof type 160SW-1RD

6 LD Bore N Stroke 6 LD Bore N Stroke

T T

Switch symbol Switch symbol


: Female thread T : Male thread

Quantity of Switch Quantity of Switch

Bore 32 - 80
Male thread
A KK W C KK depth KL N MM N EE

Width across flats D

FP RV

PJ+Stroke LG+Stroke

FP

Compact Design Hydraulic Cylinder

KK depth KL

UX1

UX2

EH LH ST

MM

MM

Width across flats D

C W SU XS LZ+Stroke SV+Stroke ZZ+Stroke2 SU W+Stroke XS+Stroke

4-SB

TS US

*Please be sure to use the Socket Head Screw when install the cylinder to the contact patch.

16MPa Compact Design Hydraulic Cylinder Double Acting Double-rod/Switch set Unit: mm

160S-1
KL LG 112 112 125 132 155 LH 35 0.15 37.5 0.15 45 0.15 50 0.15 60 0.25 LZ 72 72 75 82 95

64

General purpose type Dimension Table


Symbol A
Bore

C 7 7 8 9 14

D 14 19 24 30 41

E 62 70 80 94 114 RV

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

EH 66 72.5 85 97 117

FP 48 47 53 55 65

KK Female thread Male thread M121.75 M162 M202.5 M273 M303.5 M161.5 M201.5 M241.5 M301.5 M391.5

32 40 50 63 80 Symbol

25(40) 30(45) 35(50) 45(60) 60(80)

15 20 24 33 36

MM
Bore

N 10 10 10 10 15

PJ 16 18 19 22 25 37 41 46 53 63

SB 44 48 53 60 70 9 11 14 16 18

ST 16 20 24 30 35

SU 20 20 25 25 30

SV 92 92 100 107 125

TS 79 90 104 121 144

US 94 108 126 146 172

UX1 19 20 22 24 30

UX2 35 34 35 40 47

W 10 10 11 13 17

XS 20 20 23.5 25.5 32

ZZ 132 132 147 158 189

AX type AZ type 18 22 28 36 45

32 40 50 63 80

Compact Design Hydraulic Cylinder

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Cutting fluid proof type

Dimension Table
RV RY UX1 WS 15 20 21 24 29 UX2 AX205W WR AZ205W 11 11 14 18 22 28 33 35 36 43 WS 32 36 37 40 47
R2 5o rm

Bore Cord rear wiring Cord upper wiring Cord rear wiring Cord upper wiring AX205W WR AX205W WRWS AZ205W WRWS AX205W WRWS AZ205W WRWS AZ205W 32 40 50 63 80 37 41 46 54 63 53 57 62 69 79 44 48 53 61 70 53 57 62 69 79 74 82 92 108 126 106 114 124 138 158 88 96 106 122 140 106 114 124 138 158 13 14 16 17 22 11 17 19 20 25

ore

Recessed for the bend radius dimension.

When the switch cannot be attached as shown above, use the other type (cord upper wiring).

Note) Set the flex tube so that its bend radius becomes R25 or more. If the bend radius becomes smaller than this value, the cord may be disconnected.

Switch attachment dimensions


Cord rear wiring WR525 (contact) AX205W (no contact)
RY RV RV RV

Cord upper wiring WR535 (contact) AZ205W (no contact)


RY RV RV RV RV

WS235-1 (no contact)


RY

WS245-1 (no contact)


RY RV

65

160S-1
FA

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm
160S-1/THS16 Bore
CAD/DATA is available.

General purpose type 160S-1RD Cutting fluid proof type 160SW-1RD

6 FA Bore N Stroke 6 FA Bore N Stroke

T T

Switch symbol Switch symbol


: Female thread T : Male thread

Quantity of Switch Quantity of Switch

Bore 32 - 80
Male thread
A C KK KK depth KL N N W(WF) EE

MM Width across flats D

Y E

PJ+Stroke

Compact Design Hydraulic Cylinder

TV RV

KK depth KL

UX1

UX2 4-M

FE R

MM Width across flats D C

MM

4-FB

TF UF

LL+Stroke

WF+Stroke

*Please be sure to use the Socket Head Screw when install the cylinder to the contact patch.

16MPa Compact Design Hydraulic Cylinder Double Acting Single-rod/Switch set Unit: mm

160S-1
KK KL 15 20 24 33 36 LL 72 72 75 82 95

66

General purpose type Dimension Table


Symbol A
Bore

C 7 7 8 9 14

D 14 19 24 30 41

E 62 70 80 94 114

EE Rc1/4 Rc1/4 Rc1/4 Rc1/4 Rc3/8

F 15 20 20 20 25 RV

FB 6.6 11 14 14 18

FE 62 70 85 98 118

Female thread Male thread M121.75 M162 M202.5 M273 M303.5 M161.5 M201.5 M241.5 M301.5 M391.5

32 40 50 63 80 Symbol

25(40) 30(45) 35(50) 45(60) 60(80)

M
Bore

MM 18 22 28 36 45

N 10 10 10 10 15

PJ 16 18 19 22 25

R 40 46 58 65 87 37 41 46 53 63

TF 44 48 53 60 70 80 96 108 124 154

TV 47 52 58 69 86

UF 95 118 135 150 185

UX1 19 20 22 24 30

UX2 35 34 35 40 47

W 10 10 11 13 17

WF 10 10 11 13 17

Y 28 27 28 30 35

AX type AZ type

f32 f40 f50 f63 f80

M6 1 M8 1.25 M10 1.5 M12 1.75 M14 2

Compact Design Hydraulic Cylinder

Notes) When you use the cylinder with lock nut, we recommend you change A dimension for parenthetic one. The lock nut needs to be ordered separately. Allowance of MM is f8.

Cutting fluid proof type

Dimension Table
RV RY UX1 WS 15 20 21 24 29 UX2 AX205W WR AZ205W 11 11 14 18 22 28 33 35 36 43 WS 32 36 37 40 47
R2 5o rm

Bore Cord rear wiring Cord upper wiring Cord rear wiring Cord upper wiring AX205W WR AX205W WRWS AZ205W WRWS AX205W WRWS AZ205W WRWS AZ205W 32 40 50 63 80 37 41 46 54 63 53 57 62 69 79 44 48 53 61 70 53 57 62 69 79 74 82 92 108 126 106 114 124 138 158 88 96 106 122 140 106 114 124 138 158 13 14 16 17 22 11 17 19 20 25

ore

Recessed for the bend radius dimension.

When the switch cannot be attached as shown above, use the other type (cord upper wiring).

Note) Set the flex tube so that its bend radius becomes R25 or more. If the bend radius becomes smaller than this value, the cord may be disconnected.

Switch attachment dimensions


Cord rear wiring WR525 (contact) AX205W (no contact)
RY RV RV RV

Cord upper wiring WR535 (contact) AZ205W (no contact)


RY RV RV RV RV

WS235-1 (no contact)


RY

WS245-1 (no contact)


RY RV

67

160S-1

16MPa Compact Design Hydraulic Cylinder

Unit: mm

Special specification at the rod end


You can easily order following categolized items using the Semi-standard symbols and dimensional parameters. (No need to specify dimensional parameters if you would apply the basic dimensions.)

A00 (T)
KMKP 3 15

How to order Series Model number X Semi-standard symbols Dimensional parameters


Parameter KM and KP need to be specified as a pair.

MM

Width across flats S A WF

ex.

A83
DR

3 15

Basic Dimension Table (Standard Dimensions)


Bore A 15 18 25 30 35 45 60 KM 10 12 16 20 24 30 39 KP 1.25 1.25 1.5 1.5 1.5 1.5 1.5 MM 12 14 18 22 28 36 45 S 10 12 14 19 24 30 41 WF 8 8 10 10 11 13 17

DM

DP MM

20 25 32
FA=W SDFB=WF

Compact Design Hydraulic Cylinder

C1
A2

A 40~80 Note) Only WF dimension can be changed at A82 and A83 special rod end shape. If you would like to change other.

A83, bore:40mm, WF:60mm 160S-1 6SD40N50T-X A83 WF-60

C0
A1

.2

40 50 63 80

A51
3 15

A53
KMKP 3 15 Number of chamfering DN

MM

MM Width across flats S A WF Note) Lengthen WF dimension by combining with L dimension. WF

Basic Dimension Table


Bore 20 25 32 40 50 63 80 MM 12 14 18 22 28 36 45 WF 8 8 10 10 11 13 17

Basic Dimension Table


Bore 20 25 32 40 50 63 80 A 15 18 25 30 35 45 60 DN 2 2 2 2 2 2 2 KM 10 12 16 20 24 30 39 KP 1.25 1.25 1.5 1.5 1.5 1.5 1.5 L 0 0 0 0 0 0 0 MM 12 14 18 22 28 36 45 S 10 12 14 19 24 30 41 WF 8 8 10 10 11 13 17

Use this type when the width across flats S of the A00 are required to be moved.

Dimensions indicated by Mark are fixed as our semi-standard. You are requested to consult us if you would like to change fixed dimensions.

Unit: mm

16MPa Compact Design Hydraulic Cylinder

160S-1
A Number of beveled locations DN

68

A54
KMKP Width across flats S
Number of beveled locations DN

A81
KMKP

MM A1 A WF

MM
L

Width across flats S 3

15 WF

Basic Dimension Table


Bore 20 25 32 40 50 63 80 A 15 18 25 30 35 45 60 A1 DN KM 4 4 4 4 4 4 4 2 2 2 2 2 2 2 10 12 16 20 24 30 39 KP 1.25 1.25 1.5 1.5 1.5 1.5 1.5 L 0 0 0 0 0 0 0 MM S WF 12 14 18 22 28 36 45 10 12 14 19 24 30 41 8 8 10 10 11 13 17

Basic Dimension Table


Bore 20 25 32 40 50 63 80 A 10 12 15 20 24 33 36 DN 2 2 2 2 2 2 2 KM 8 10 12 16 20 27 30 KP 1.25 1.5 1.75 2 2.5 3 3.5 L 0 0 0 0 0 0 0 MM 12 14 18 22 28 36 45 S 10 12 14 19 24 30 41 WF 8 8 10 10 11 13 17

Compact Design Hydraulic Cylinder

A82
3 15 DR 3 15

Exclusive M joint on the following pages.

A83
3 DR 15

DM DP MM

DM

DP MM

A2

FA=W A1 SDFB=WF A

C1
A2

Basic Dimension Table (Standard dimension)


W WF +0.5 0.2 0.2 Bore A A1+0.3 A20.3 DM DP0.3 DR MM A A A FA type SDFB type 20 25 25 25 32 25 40 25 50 25 63 30 80 30 12.5 12.5 12.5 12.5 12.5 15 15 12.5 12.5 12.5 12.5 12.5 15 15 12 14 18 22 28 36 45 8 10 13 16 21 26 31 0.5 12 20 0.5 14 20 1.0 18 30 1.5 22 35 1.5 28 35 2.0 36 40 2.0 45 45 20 20 30 35 35 40 45

C0 .2

A 40~80

Basic Dimension Table (Standard dimension)


W WF +0.5 0.2 0.1 0.2 DP 0.3 DR MM A2 0.3 DM 0.4 Bore A A1+0.3 A A D FA type SDFB type 40 25 50 25 63 25 80 30 12.5 12.5 12.5 15 12.5 12.5 12.5 15 18 22 28 36 13 16 21 26 1.0 22 35 1.5 28 35 1.5 36 40 2.0 45 45 35 35 40 45

Dimensions indicated by Mark are fixed as our semi-standard. You are requested to consult us if you would like to change fixed dimensions.

C0
A1

.2

FA=W SDFB=WF

69

160S-1

16MPa Compact Design Hydraulic Cylinder

Unit: mm

Separate flange joint : Only for A82 rod end style

F G

45

4-D3 Reverse face/counter hole diameter D4 depth H

D1

D2

Compact Design Hydraulic Cylinder

B 3

Need additional order for this item. Part No.: RMH-(bore(mm))

C C

Unit: mm

16MPa Compact Design Hydraulic Cylinder

160S-1
E 19.6 19.6 18.5 16.4 14.2 19.2 17 F 25 25 25 25 25 30 30 G 12.5 12.5 12.5 12.5 12.5 15 15 H 5.4 5.4 6.5 8.6 10.8 10.8 13 J 29 31 34 40 50 55 76

70

Dimension Table
Symbol Parts code
Bore

A 44 46 49 57 71 77 100

B 20.5 21.5 23 27 34 37 48.5

C 0.5 0.5 1 1.5 1.5 2 2

D1 13 15 19 23 29 38 48

D2 8.5 10.5 13.5 16.5 21.5 27 33

D3 5.5 5.5 6.6 9 11 11 14

D4 9.5 9.5 11 14 17.5 17.5 20

20 25 32 40 50 63 80

RMH-12 RMH-14 RMH-18 RMH-22 RMH-28 RMH-36 RMH-45

Compact Design Hydraulic Cylinder

Вам также может понравиться