Вы находитесь на странице: 1из 2

Integrated Solutions

Plant|Flexibility
Peak Power
Questionnaire on
Operational Plant Flexibility Issues

Would you like to have a discussion on operational plant flexibility issues, related to improved overload capability, improved minimum load capability and reduction of power limitations due to supply of frequency support with an ALSTOM specialist? ALSTOM Thermal Power offers sophisticated solutions for your specific problems from its broadly based product portfolio. Please answer the following short questions and contact us.
Unit name Unit operator Unit size and quantity,
457MW e.g. 3 x

MW

Location Plant age, operating hours total and expected operating life Brief descriptions: Additional Process Data: Main Steam: p...........bar T...........C m..........kg/s Cold Reheat: p...........bar T...........C Hot Reheat: p...........bar T...........C Condenser: p...........bar T...........C Final Feed Water: p...........bar T...........C

Years
Type and lower heating value of primary fuel:

Hrs

Year 20__

Boiler Type and manufacturer (e.g. drum-type natural convection, Benson, etc.):

Predominant boiler operation mode (e.g. fixed or sliding pressure): Turbine Manufacturer and brief description (e.g. HP/IP LP, full arc admission, reheat):

Turbine Condenser Type and Manufacturer:

Manufacturer and Type of DCS:

For which operation mode has the power plant been designed? What is the current operation mode of the power plant? Are you interested in temporarily supply of additional power output / improved overload

Base Load

Intermediat Peak Load e Intermediat Peak Load e No

Base Load Yes

www.alstom.com/power/

THERMAL POWER

capability? How much is the reserve margin of you generator How long should additional power output be available How often should additional power output be available Are you interested in a lower minimum electrical load operation mode (e.g. at night)? What is the minimum electrical load with stable coal combustion? How long should the reduction of minimum load be available? On average how often is the unit shut down (e.g.at night or during the weekend)? Does the unit use condensate stop? Do you supply frequency support services for the grid? Are you interested in reduction of power limitations due to the supply of frequency support? Please provide the load profile for the unit for a representative time, e.g. 1 week (please attach) Please provide the current heat balance diagrams (max/min load) (please attach) What are the condensate parameters after the feed water tank (before entry in feed water pump)? What are the condensate parameters after the last LP-heater (before entry in feed water tank)? What are the condensate parameters before the condensate pump(s)? What is the main condensate mass flow at full load? kg/s How much free space is available on the power plant site? Other comments miscellaneous if applicable; Width x length

MW hrs/day times/day
Yes No MW hrs/day times/week times/month No

Yes

Primary control MW Positive secondary control MW Negative secondary control MW Yes No Attachment reference no.: Attachment reference no.: min min min min min min Min C bar C bar C bar load max max max max max max Full load C bar C bar C bar kg/s

Your local service partner:

<INSERT BROCHURE REFERENCE NUMBER> - ALSTOM <INSERT YEAR>. ALSTOM, the ALSTOM logo and any alternative version thereof are trademarks and service marks of ALSTOM. The other names mentioned, registered or not, are the property of their respective companies. The technical and other data contained in this document is provided for information only. Neither ALSTOM, its officers and employees accept responsibility for or should be taken as making any representation or

<SECTOR>

Вам также может понравиться