Вы находитесь на странице: 1из 15

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

Chapter 8 PCF Call Processing Measurement


PCF Call Processing Measurement includes:

Performance Stat of Packet Call Activation Inter-PCF Handoff Performance Stat

The PCF call processing in the CDMA2000 1X system is the same as that in the CDMA2000 1xEV-DO system.

8.1 Performance Stat of Packet Call Activation


8.1.1 MS/AT Reactivate Attempts [Times]
Definition Number of call activation requests originated by the mobile station/ access terminal (MS/AT) in the dormant state. Unit Type Measurement method Measurement point The BSC measures every time the PCF receives an A9-Setup-A8 message from a BS/AN after the MS/AT in the dormant state originates an activation request. See the A in 8.1.12 IFigure 1.1. Time Original item By accumulation

Huawei Technologies Proprietary 1

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

8.1.2 Successful MS/AT Reactivations [Times]


Definition Times of successful call activation originated by the MS/AT in the dormant state. Unit Type Measurement method Measurement point After the MS/AT in the dormant state originates an activation request, the PCF processes the A9-Setup-A8 message sent by the BS/AN. The BSC measures every time the PCF returns an A9-Connect-A8 message to the BS/AN after successfully processing the A9-SetupA8 message. See the B in 8.1.12 IFigure 1.1. Time Original item By accumulation

8.1.3 PCF Reactivate Attempts [Times]


Definition Number of call activation requests originated by the PCF when the MS/AT is in the dormant state. Unit Type Measurement method Measurement point The BSC measures every time the PCF sends the BS/AN an A9BS-Service-Request upon receiving data from the network side with the MS/AT in the dormant state. See the A in 8.1.12 IIFigure 1.1. Time Original item By accumulation

Huawei Technologies Proprietary 2

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

8.1.4 Successful PCF Reactivations [Times]


Definition Times of successful call activation originated by the PCF when the MS/AT is in the dormant state. Unit Type Measurement method Measurement point After receiving data from the network side when the MS/AT is in the dormant state, the PCF sends the BS/AN an A9-BS-ServiceRequest message. The BSC measures every time the PCF returns an A9-ConnectA8 message to the BS/AN after processing the A9-Setup-A8 message from the BS/AN. See the B in 8.1.12 IIFigure 1.1. Time Original item By accumulation

8.1.5 MS Sends SDB [Times]


Definition Number of short data bursts (SDBs) that the MS in the dormant state sends. Unit Type Measurement method Measurement point The BSC measures every time the PCF receives an A9-ShortData- Delivery message from the BS when the MS is in the dormant state. Time Original item By accumulation

Huawei Technologies Proprietary 3

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

8.1.6 PCF Sends SDB [Times]


Definition Number of SDBs that the PCF sends when the MS is in the dormant state. Unit Type Measurement method Measurement point The BSC measures every time the PCF successfully sends the BS an A9-Short-Data-Delivery message with the MS in the dormant state. Time Original item By accumulation

8.1.7 Access Requests by Packet Service Subscribers [Times]


Definition Number of setup requests for data service calls that the PCF receives when the MS/AT is in the null state. Unit Type Measurement method Measurement point The BSC measures every time the PCF receives an A9-Setup-A8 message from the BS/AN with the MS/AT in the null state. See the A in 8.1.12 IIIFigure 1.1. Time Original item By accumulation

Huawei Technologies Proprietary 4

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

8.1.8 Successful Accesses of Packet Service Subscribers [Times]


Definition Number of successful call setups at the setup requests for data service calls that the PCF receives when the MS/AT is in the null state. Unit Type Measurement method Measurement point The BSC measures every time the PCF returns an A9-ConnectA8 message to the BS/AN after it receives an A9-Setup-A8 message from the BS/AN and the call is successfully set up with the MS/AT in the null state. See the B in 8.1.12 IIIFigure 1.1. Time Original item By accumulation

8.1.9 Times of Congestion on PCF [Times]


Definition Number of call setup failures of data services owing to PCF congestion after the PCF receives setup requests for data service calls with the MS/AT in the null state. Unit Type Measurement method Measurement point The BSC measures every time the PCF returns an A9-ConnectA8 message to the BS/AN after it receives an A9-Setup-A8 message from the BS/AN with the MS/AT in the null state but the call setup fails. The call setup failure results from intra-PCF resources allocation failures. See the C in 8.1.12 IIIFigure 1.1. Time Original item By accumulation

Huawei Technologies Proprietary 5

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

8.1.10 Max Times of PPP Activation on PCF [Entries]


Definition Maximum number of PCF subscribers in the active state within a current measurement period. Unit Type Measurement method Measurement point The BSC measures the number of PCF subscribers in the active state every five minutes. It reports the maximum value in a measurement period. Time Original item By setting

8.1.11 Max Times of PPP Dormancy on PCF [Entries]


Definition Maximum number of PCF subscribers in the dormant state within a current measurement period. Unit Type Measurement method Measurement point The BSC measures the number of PCF subscribers in the dormant state every five minutes. It reports the maximum value in a measurement period. Time Original item By setting

8.1.12 Flowcharts
In the CDMA2000 1X and CDMA2000 1xEV-DO networks, BSs/ANs connect with PCFs through A8/A9 interface. As for PCFs, A8/A9 interface is the same in the CDMA2000 1X and CDMA2000 1xEV-DO networks. Thus, measurement items are described hereinafter regardless of any difference between the CDMA2000 1X network and the CDMA2000 1xEV-DO network.

I. Activation Originated by the MS/AT


Figure 1.1 marks the measurement points of associated measurement items in the process of PCF activation originated by the MS/AT. Message exchange between the

Huawei Technologies Proprietary 6

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

MS and BS, BS and MSC, and AT and AN is omitted.


MS/AT BS/AN PCF PDSN

Dormant,PPP connection is maintained

A9-Setup-A8

A B

A: MS Reactivate Attempts B: Successful MS Reactivations

Figure 1.1 Performance Stat of Packet Call Activation (activation originated by the MS/AT)

II. Activation Originated by Network Side


Figure 1.1 marks the measurement points of associated original items in the process of activation originated by the network side.

A9-Connect-A8

Active Packet Data Session

Huawei Technologies Proprietary 7

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

MS/AT

BS/AN

PCF

PDSN

Dormant, PPP connection is maintained Packet Data Traffic A9-BS Service Request A

A9-BS Service Response

A: PCF Reactivate Attempts B: Successful PCF Reactivations

Figure 1.1 Performance Stat of Packet Call Activation (activation originated by the network side)

III. Calls Originated by the MS/AT


Figure 1.1 marks the measurement points of associated measurement items in the process of PCF call originated by the MS/AT. Message exchange between the MS and BS, BS and MSC, and AT and AN is omitted.

Huawei Technologies Proprietary 8

A9-Setup-A8 A9-Connect-A8 B Active Packet Data Session

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

MS/AT

BS/AN

PCF

PDSN

A9-Setup-A8

A A11-Registration-Request (Life Time)

A: Access Requests by Packet Service Subscribers B: Successful Accesses of Packet Service Subscribers C: Times of Congestion on PCF

Figure 1.1 Performance Stat of Packet Call Activation (call originated by the MS/AT)

In case of success: A9-Connect-A8 In case of failure: A9-Disconnect-A8

A11-Registration-Reply (Life Time, Accept)

Establishing PPP connection, Mobile IP Registration

Transmitting packet data

Huawei Technologies Proprietary 9

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

8.2 Inter-PCF Handoff Performance Stat


8.2.1 Incoming HOs to this PCF with MS Active [Times]
Definition Number of handoffs to the target PCF when the MS is in the active state. Unit Type Measurement method Measurement point The BSC measures every time the target PCF receives an A9Setup-A8 message with the data ready indicator DRI and handoff indicator HO set to "1" when the MS is in the active state. See the A in 8.2.6 IFigure 1.1. Time Original item By accumulation

8.2.2 Outgoing HOs from this PCF with MS/AT Active [Times]
Definition Number of handoffs from the source PCF when the MS is in the active state. Unit Type Measurement method Measurement point The BSC measures every time the source PCF receives an A9AL-Disconnected message with the MS in the active state. See the B in 8.2.6 IFigure 1.1. Time Original item By accumulation

Huawei Technologies Proprietary 10

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

8.2.3 Incoming HOs to this PCF with MS/AT Dormant [Times]


Definition Number of handoffs to the target PCF when the MS/AT is in the dormant state. Unit Type Measurement method Measurement point The BSC measures every time the target PCF receives an A9Setup-A8 message with the data ready indicator DRI and handoff indicator HO set to "0" when the MS/AT is in the dormant state. See the A in 8.2.6 IFigure 1.1 and 8.2.6 IIFigure 1.1. Time Original item By accumulation

8.2.4 HO Requests by Packet Service Subscribers [Times]


Definition Number of A9-Setup-A8 messages that the target PCF receives when the MS/AT is in the dormant or active state. Unit Type Measurement method Measurement point The BSC measures every time the target PCF receives an A9Setup-A8 message when the MS/AT is in the dormant or active state. The data ready indicator DRI and the handoff indicator HO are set to "0" or "1". See the A in 8.2.6 IFigure 1.1, 8.2.6 IIFigure 1.1, and 8.2.6 IIIFigure 1.1. Time Original item By accumulation

Huawei Technologies Proprietary 11

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

8.2.5 Successful HOs of Packet Service Subscribers [Times]


Definition Number of successful handoffs to the target PCF when the MS/AT is in the dormant or active state. Unit Type Measurement method Measurement point The BSC measures every time the target PCF receives an A9Setup-A8 message with the data ready indicator DRI and handoff indicator HO set to "0" or "1" when the MS/AT is in the dormant or active state, and the handoff message is successfully processed. See the C in 8.2.6 IFigure 1.1, the B of 8.2.6 IIFigure 1.1, the B of and 8.2.6 IIIFigure 1.1. Time Original item By accumulation

8.2.6 Flowcharts
I. Inter-PCF Active HOs in the PDSN
Figure 1.1 marks the measurement points of associated original items in the process of inter-PCF active HO in the PDSN.

Huawei Technologies Proprietary 12

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller Source BS Source PCF Target BS

Chapter 8 PCF Call Processing Measurement

MS

Target PCF

MSC

PDSN

Handoff Required Handoff Request A9-Setup-A8 A

A9-Connect-A8 Handoff Request Ack Handoff Command B A9-AL Disconnected A9-AL Disconnected Ack GHDM/UHDM MS Ack Order Handoff Commenced Handoff Completation BS Ack Order A9-ALConnected A11-Registration-Request A11-Registration-Reply A9-AL Connected Ack Handoff Complete Clear Command A9-Release-A8 A11-Registration-Request(Lifetime=0) A11-Registration-Reply A9-Release-A8 Complete C Clear Complete

A: Incoming HOs to this PCF with MS Active HO Requests by Packet Service Subscribers B: Outgoing HOs to this PCF with MS Active C: Successful HOs of Packet Service Subscribers

Huawei Technologies Proprietary 13

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

Figure 1.1 Inter-PCF Handoff Performance Stat (inter-PCF active HO in the PDSN)

II. Inter-AN Dormant HOs


Figure 1.1 marks the measurement points of associated original items in the process of inter-AN dormant HO.
AT Target AN UATIRequest A13-Session Information Request A13-Session Information Response HardwareIDRequest HardwareIDResponse UATIAssignment UATIComplete LocationNotification LocationAssignment LocationComplete A13-Session Information Confirm A9-Setup-A8 A A11-Registration-Request (Life Time) A11-Registration-Reply (Life Time, Accept) A11-Registration-Update A11-Registration-Ack A11-Registration-Request A11-Registration-Reply A9-Release-A8-Complete B Target PCF Source AN Source PCF PDSN

A: Incoming HOs to this PCF with MS/AT Dormant HO Requests by Packet Service Subscribers B: Successful HOs of Packet Service Subscribers

Figure 1.1 Inter-PCF Handoff Performance Stat (inter-AN dormant HO)

Huawei Technologies Proprietary 14

Performance Measurement Reference Manual Airbridge cBSC6600 CDMA Base Station Controller

Chapter 8 PCF Call Processing Measurement

III. Inter-PCF Dormant HOs in the PDSN


Figure 1.1 marks the measurement points of associated original items in the process of inter-PCF dormant HO in the PDSN.
MS Source BS Target BS
MSC

Source PCF

Target PCF

PDSN

Dormant,PPP connection is maintained

Origination Message BS Ack Order CM Service Request Assignment Request A9-Setup-A8


A

A11-Registration-Request A11-Registration-Reply A9-Release-A8 Complete Assignment Failure Clear Command Clear Complete A11-Registration-Update A11-Registration-Ack A11-Registration-Request A11-Registration-Reply
B

Dormant Packet Data Session

A: Incoming HOs to this PCF with MS/AT Dormant HO Requests by Packet Service Subscribers B: Successful HOs of Packet Service Subscribers

Figure 1.1 Inter-PCF Handoff Performance Stat (inter-PCF dormant HO in the PDSN)

Huawei Technologies Proprietary 15

Вам также может понравиться