VIKING HEAVY DUTY PUMPS

SERIES 125 AND 4125 STANDARD CONSTRUCTION FEATURES

Section Page Issue

141 141.1 D

Cutaway View (Packed Type) 8-15-30 GPM Sizes (2-3-7 m/hr)

SERIES 125 Pumps

Note: 50 and 75 GPM sizes have seal located in stuffing box area.

Cutaway View (Mechanical Seal Type) 50-75-100-135 GPM Sizes (11-17-23-31 m/hr)

SERIES 4125

MECHANICAL SEAL (SERIES 4125) G-HL, K-LL SIZES AK, AL, LS-M SIZES
BRACKET

Note: 500 GPM (QS size) has opposite ports as standard.

Cutaway View (Packed Type) 140-200-300-420-500 GPM Sizes (32-45-68-95-114 m/hr)

SERIES 125 Pumps

Pressure Range Temperature Range Viscosity Range

200 PSI (14 BAR) for 100 SSU (21 cSt) and above 100 PSI (7 BAR) for below 100 SSU (21 cSt) -60F. to +650F. (-51C. to +343C.) 28 SSU to 2,000,000 SSU (0.1 cP to 440,000 cSt)

BRACKET

ROTOR

SHAFT

SHAFT

Bellows O-Ring Rotating Face Stationary Seat Metal Retainer Spring

Bellows O-Ring Rotating Face Stationary Seat Metal Retainer Spring

Set Collar Seal Holder Seal Plate

FEATURES

REVOLVABLE PUMP CASING (Standard Equipment)


All Series 125 and 4125 pumps are equipped with pump casings that can be turned to eight positions except the LQ, LL, and QS sizes. These can be turned in all positions except for a port in the 6 oclock position. Relief valve must point to suction port in all cases.

OVERPRESSURE RELIEF VALVE (Standard Equipment)


Valve permits bypassing of liquids and prevents excessive pressures in the discharge line. If reversing pump, remove valve and turn end for end. Relief valve must point to suction port in all cases. All valves set at 50 lbs. unless otherwise requested. If overpressure relief valve is not used, pumping system should include some form of overpressure protection, e.g., relief valve in discharge line, torque limiting devices, rupture discs, etc.

(Nominal Rating) It is the unique and unusually simple construction that has made our rotary pumps so adaptable to so many diversified installations. They possess excellent vacuum developing characteristics and operate equally well in either direction. Because of the cushioned action in providing a continuous and steady stream of liquid without foaming or churning, it is adaptable to an unlimited number of industrial applications. The rugged construction of these heavy-duty pumps assures long life and peak, trouble-free operation on normal-duty installation and outstanding performance when handling liquids at greater pressures. These heavy-duty pumps are furnished as standard with packed-type or mechanical seal construction for shaft protection and prevention of leakage. Packed pumps provide extra-deep stuffing box. The rotarytype mechanical seal works with, rather than against, pressure. It is self-adjusting and seals without leakage. Because of its method of sealing it prevents scoring of the pump drive shaft. The Series 4125 mechanical seal pumps can handle liquids with viscosities up to 15,000 SSU. Special seals for higher viscosities are available; consult factory.
Values shown represent minimums or maximums. Some special construction or
consideration may be required before a cataloged pump can be applied to an application involving maximum pressure or minimum or maximum temperature and/or viscosity. Certain models have restrictions in pressure and/or viscosities. See specifications, page 141.2, and performance curves.

(m/hr 2-3-7-11-17-23-31-32-45-68-95-114)

GPM 8-15-30-50-75-100135-140-200-300-420-500

POSITIVE-LOCK THRUST CONTROL


Series 125 and 4125 pumps are manufactured with positive-lock thrust control for accurate axial positioning of rotor and shaft. Illustration shows bearing and double end cap arrangement.

Nominal capacities based on handling thin liquids at low pressures.


Metric conversions are based on US measurements and rounded to the nearest whole number.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

141 141.2 D

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125 UNMOUNTED PUMPS

G, H, and HL Sizes

AK and AL Sizes

LS Size

Q and M Sizes

K, KK, and L Sizes

LQ and LL Sizes

QS Size

This series of heavy-duty pumps is available either revolvable casing feature on Page 141.1. Overpressure unmounted or mounted as shown on following pages. relief valve on head is standard for this series. To permit Available with packed stuffing box or Buna-N mechanical use of this type pump in a greater range of applications, seal with carbon rotating and Ni-Resist stationary faces. some sizes are available with jacketed head plate. For The integral thrust bearing is designed to handle heavyheavy-duty pumps with jacketed bracket and head, see duty pumping jobs without problems of end play and Catalog Section 142. distortion. For increased versatility of installation and Dimensions for Unmounted PumpsSee Page 141.8. complete selection of ports, many of the pump casings Performance Data for Unmounted PumpsSee Pages 141.15 through 141.42. are designed so they can be rotated on the bracket to any 45 or 90 angle from that shown in the illustrations. See CONSTRUCTION SERIES 125 AND 4125 (G THROUGH M SIZES)
Pump Construction Standard Construction Steel Fitted Bronze Fitted Casing Iron Iron Iron Head Iron Iron Iron Bracket Iron Iron Iron Rotor Iron Steel Bronze Idler Iron Iron Bronze Rotor Shaft And Idler Pin Steel Steel Steel Bushings Packed Idler Bronze Bronze Bronze Bracket Bronze Bronze Bronze Mechanical Seal Idler Carbon Graphite Carbon Graphite Carbon Graphite Bracket Bronze Bronze Bronze Internal Pressure Relief Valve Iron Iron Iron

SPECIFICATIONS SERIES 125 AND 4125 UNMOUNTED PUMPS


Model Numbers Packed G125 H125 HL125 AK125 AL125 K125 KK125 L125 LQ125 LL125 LS125 Q125 QS125 M125 Mech. Seal G4125 H4125 HL4125 AK4125 AL4125 K4125 KK4125 L4125 LQ4125 LL4125 LS4125 Q4125 QS4125 M4125 Port Size Inches 1 1 1 2 2 2 2 2 2 3 3 4 6 4 Nominal Pump Rating Maximum Hydrostatic Pressure RPM 1800 1800 1800 1200 1200 780 780 640 640 520 640 520 520 420 PSIG (BAR) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28)

Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7,500 (1,650) 25,000 (5,500) 7,500 (1,650) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 2,500 (550) 75,000 (16,500) 7,500 (1,650) 75,000 (16,500) 25,000 (5,500)

Maximum Recommended Discharge Pressure When Handling 100 SSU Liquid At Nominal Rated Speeds PSIG 200 200 200 150 150 200 200 200 200 200 150 150 150 150

Maximum Recommended Temperature for Cataloged Pump F. (C.) Packed 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) Mech. Seal 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107)

Approximate Shipping Weight With Valve Pounds (KG) 22 38 40 78 81 105 110 155 175 185 190 440 540 600 (10) (17) (18) (35) (37) (48) (500 (70) (79) (84) (86) (200) (245) (272)

GPM (m/hr) 8 15 30 50 75 75 100 135 135 (2) (3) (7) (11) (17) (17) (23) (31) (31)

140 (32) 200 (45) 300 (68) 500 (114) 420 (95)

Buna-N elastomer used in mechanical seal of Series 4125 pumps. Viton , Neoprene, and Teflon mechanical seals also available. G, Q, and QS sizes have steel idler. For mechanical seal pumps on applications with viscosities above 15,000 SSU (3,300 cSt), provide details for recommendation. Ports are suitable for use with 125# ANSI cast iron or 150# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. Standard seal can be used from -20F. to +225F. With special construction, temperatures from -60F. to +650F. can be handled with this series pumps. Nominal rating based on handling thin liquids. AK, AL, KK, LS, and QS sizes have ductile iron rotor.
Metric conversions are based on US measurements and rounded to the nearest whole number.

For maximum recommended discharge pressures when handling other viscosities and/or other speeds, see performance curves. Performance curves also show preferred constructions. If suction pressure exceeds 50 PSIG (3 BAR), consult factory. Check factory before using bronze rotors at viscosities normally requiring steelfitted construction. G, AK, AL, LS, and QS sizes not available in bronzefitted construction. AK, AL, LS, Q, QS, and M 4125 models furnished with carbon graphite bracket bushings and mechanical seal is mounted in stuffing box. Mechanical seal is mounted behind rotor in G, H, HL, K, KK, L, LQ, and LL pumps. AK and AL sizes not available in steel-fitted construction.
Teflon Registered trademark of E.I. DuPont Company. Viton Registered trademark of DuPont Dow Elastomers L.L.C.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125 VIKING HELICAL GEAR REDUCTION UNITS (R DRIVE)

Section Page Issue

141 141.3 D

SERIES 125 and 4125 Pumps


with R Drive A Reducer

SERIES 125 and 4125 Pumps


with R Drive B Reducer

SERIES 125 and 4125 Pumps


QS Size with R Drive C Reducer

SERIES 125 and 4125 Pumps


with R Drive C Reducer

Heavy-duty pump Series 125 and 4125 are available with helical gear reducers that have been specifically developed for efficient operation with heavy-duty pumps. These rugged, compact, exceptionally quiet gear reducers come in three sizes: the small A size, medium B size, and large C size and are all bracket mounted requiring flexible couplings for both input and output shafts. The A size reducer, available with four gear ratios (2.24, 2.76, 3.43, and 4.17 to 1), is ideally suited for use with the G, H, HL, AK and AL size pumps. With the A size reducer and 1200 or 1800 RPM motors, the G, H, HL, AK, and AL size pumps can be used to cover a capacity range to 51 GPM. The medium size B helical gear reducer is available

with eight gear ratios from 1.87 to 1 to 7.65 to 1. This size normally is used with pump sizes AK through LS. With the B reducer, AK through LS pumps driven by 1200 or 1800 RPM motors can be used to cover a capacity range to 213 GPM. The large C size reducer also is available with seven gear ratios from 2.21 to 1 to 7.65 to 1. It is normally used with the KK through M size pumps. With the C reducer, KK through M size pumps driven by 1200 or 1800 RPM motors can cover a capacity range to 500 GPM.
Dimensions for R Drive Units See Pages 141.9 and 141.10. Performance Data for R Drive UnitsSee Pages 141.15 through 141.42.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

141 141.4 D

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125

VIKING HELICAL GEAR REDUCER UNITS (R DRIVE)

SPECIFICATIONS R DRIVE UNITS


Steel-Fitted Construction Recommended Above This Viscosity SSU (cSt) 7,500 (1,650) 25,000 (5,500) 7,500 (1,650) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 2,500 (550) 75,000 (16,500) 7,500 (1,650) 75,000 (16,500) 25,000 (5,500) Maximum Recommended Discharge Pressure When Handling 100 SSU Liquid At Nominal Rated Speeds PSIG 200 200 200 150 150 200 200 200 200 200 150 150 150 150 Maximum Recommended Temperature For Cataloged Pump F. (C.) Packed Mech. Seal A Reducer Approximate Shipping Weight With Valve (Less Power) Pounds (KG) B Reducer ... ... ... C Reducer ... ... ... ... ... ... 550 (250) 590 (268) 625 (297) 655 (318) 700 (454) 1000 (499) 1100 (499) 1140 (518)

Model Numbers Packed G125R H125R HL125R AK125R AL125R K125R KK125R L125R LQ125R LL125R LS125R Q125R QS125R M125R Mech. Seal G4125R H4125R HL4125R AK4125R AL4125R K4125R KK4125R L4125R LQ4125R LL4125R LS4125R Q4125R QS4125R M4125R

Port Size Inches 1 1 1 2 2 2 2 2 2 3 3 4 6 4

Nominal Pump Rating GPM (m/hr) 8 15 30 50 75 75 (2) (3) (7) (11) (17) (17) RPM 1800 1800 1800 1200 1200 780 780 640 640 520 640 520 520 420

Maximum HydroStatic Pressure PSIG (BAR) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28)

300 (149) 225 (107) 109 (49) 300 (149) 225 (107) 125 (57) 300 (149) 225 (107) 130 (59)

300 (149) 225 (107) 170 (77) 300 (136) 300 (149) 225 (107) 173 (79) 303 (138) 300 (149) 225 (107) 300 (149) 225 (107) 300 (149) 225 (107) 300 (149) 225 (107) 300 (149) 225 (107) 300 (149) 225 (107) 300 (149) 225 (107) 300 (149) 225 (107) 300 (149) 225 (107) ... ... ... ... ... ... ... ... ... 327 (148) 334 (152) 380 (173) 415 (188) 445 (202) 490 (222) ... ... ...

100 (23) 135 (31) 135 (31) 140 (32) 200 (45) 300 (68) 500 (114) 420 (95)

Buna-N elastomer used in mechanical seal of Series 4125 pumps. Viton Neoprene, and Teflon mechanical seals also available. For mechanical seal pumps on applications with viscosities above 15,000 SSU (3,300 cSt), provide details for recommendation. For maximum recommended discharge pressures when handling other viscosities and/or at other speeds, see performance curves. If suction pressure exceeds 50 PSIG (3 BAR), consult factory.
Metric conversions are based on US measurements and rounded to the nearest whole number.

Ports are suitable for use with 125# ANSI cast iron or 150# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. Nominal rating based on handling thin liquids. Standard seal can be used form -20F. to +225F. With special construction, temperatures from -60F. to +650F. can be handled with this series pumps. AK and AL sizes not available in steel-fitted construction.

OUTSTANDING FEATURES 1. Mounts NEMA standard motors, 1200 or 1800 RPM. (5 HP, 1800 RPM maximum with A reducer; 15 HP, 1800 RPM maximum with B reducer; and 50 HP, 1800 RPM maximum with C reducer.) 2. Complete reducers within a size may be interchanged on a pump unit to obtain desired pump speeds and capacities. Thus the four gear ratios within the A size reducer may be interchanged within the size by selecting the proper pinion and gear of a common ratio. Similarly, all eight B reducers are interchangeble on each respective series of B reducer units. All seven C reducers are interchangeable on each respective series of C reducer units. 3. Quiet operation. High hardness helical gears run in a bath of oil. 4. Compact, narrow and low to fit in small space and low overhead.

5. Pump, motor, or reducer can be removed without disturbing the other two components. 6. Units with A, B and C reducers have standard flexible coupling with guard between power and reducer as well as between reducer and pump. 7. Oil and weathertight for outdoor service. 8. Ball bearings throughout. 9. Reducers easily adjustable to different motor center heights. 10. Self-supported. Not hung on pump or motor shafts. No radial load on pump or motor shafts. 11. A reducers have dia., key input and output shafts; B reducers have 1 dia., key input shaft and 1 dia., key output shaft; C reducers have 1 dia., key input and output shafts.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125 VIKING HELICAL GEAR REDUCTION UNITS (R DRIVE)
HELICAL REDUCER HORSEPOWER TABLE A SIZE
HIGH SPEED SHAFT INPUT RPM 1750 1450 1150 950 GEAR REDUCER RATIOS A SIZE 2.24:1 780 6.1 640 5.2 520 4.3 420 3.6 2.76:1 640 4.9 520 4.2 420 3.4 350 2.9 3.43:1 520 3.8 420 3.2 350 2.6 280 2.2 4.17:1 420 3.1 350 2.7 280 2.2 230 1.8

Section Page Issue

141 141.5 D

LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP

For input speeds higher than 1750 RPM, consult the factory. Horsepower ratings based on 8-10 hours operation per day, electric motor drive. See Catalog Section 610 for specific reducer sizing information.

HELICAL REDUCER HORSEPOWER TABLE B SIZE


HIGH SPEED SHAFT INPUT RPM 1750 1450 1150 950 GEAR REDUCER RATIOS B SIZE 1.87:1 950 19.0 780 17.3 640 16.5 520 15.5 2.24:1 780 17.0 640 15.5 520 14.0 420 12.8 2.76:1 640 15.0 520 13.4 420 11.6 350 10.1 3.40:1 520 13.0 420 11.6 350 10.1 280 9.0 4.19:1 420 11.0 350 9.9 280 8.5 230 7.6 5.06:1 350 9.5 280 8.5 230 7.3 190 6.0 6.27:1 280 7.6 230 6.4 190 5.3 155 4.3 7.65:1 230 6.4 190 5.4 155 4.4 125 3.7 LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP

For input speeds higher than 1750 RPM, consult the factory. Horsepower ratings based on 8-10 hours operation per day, electric motor drive. See Catalog Section 610 for specific reducer sizing information.

HELICAL REDUCER HORSEPOWER TABLE C SIZE


HIGH SPEED SHAFT INPUT RPM 1750 1450 1150 950 GEAR REDUCER RATIOS C SIZE 2.21:1 780 49.8 640 45.3 520 40.1 420 29.1 2.80:1 640 43.5 520 36.6 420 30.0 350 24.7 3.31:1 520 39.0 420 32.8 350 26.8 280 22.1 4.21:1 420 32.4 350 27.2 280 22.2 230 18.3 5.08:1 350 26.6 280 22.3 230 18.2 190 15.0 6.24:1 280 19.7 230 16.7 190 13.8 155 11.4 7.95:1 220 18.0 180 15.2 145 12.6 120 10.4 LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP

For input speeds higher than 1750 RPM, consult the factory. Horsepower ratings based on 8-10 hours operation per day, electric motor drive. See Catalog Section 610 for specific reducer sizing information.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

141 141.6 D

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125
GEAR REDUCER UNITS (P DRIVE) AND DIRECT DRIVE UNITS (D DRIVE)
SERIES 125 and 4125 Pumps
with P Drive K through LS Sizes

SERIES 125 and 4125 Pumps


with P Drive Q through M Sizes (shown without pressure relief valve)

Heavy-duty Series 125 and 4125 packed and mechanical seal pumps in sizes from K through M are available in the P drive arrangement. These heavy-duty units are mounted on formed steel bases (K through LS sizes) and structural or formed steel bases (Q through M sizes) as illustrated above.

All mount separate heavy-duty reducers with flexible couplings between pump, reducer, and motor. Coupling guards as illustrated are standard construction. Contact factory for specifications and motor horsepower range.
Dimensions for P Drive Units Consult Factory. Performance Data for P Drive Units See Pages 142.27 through 141.42.

SERIES 125 and 4125 Pumps


with D Drive G, H and HL Sizes

SERIES 125 and 4125 Pumps


with D Drive AK and AL Sizes

The Direct Drive D mounting is specifically designed for compactness and quietness of operation. In this type assembly the pump is mounted on one end of a rectangular formed steel base and connected to a motor by means of a flexible coupling with guard. G, H, and HL sizes can be directly connected to 1800 RPM motors as well as gearhead motors. AK and AL size pumps are direct connected to 1200 RPM motors or gearhead motors providing high-capacity, compact pumping unit.
Dimensions for D Drive Units (G through AL sizes) See Page 141.9. Performance Data for D Drive UnitsSee Pages 141.15 through 141.42.

SERIES 125 and 4125 Pumps


with D Drive, Gearhead Motor K through M Sizes

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125 V-BELT DRIVE UNITS (V DRIVE)

Section Page Issue

141 141.7 D

SERIES 125 and 4125 Pumps


with V Drive G through M Size Pumps

V-belt driven line of heavy-duty Series 125 and 4125 pumps are all mounted on formed welded steel bases. Pumps mount on pads to accept totally enclosed V-belt drive. All units in this series feature standard pump shaft extension with totally guarded V-driven pulley mounted on end of heavy-duty pump shaft. SPECIFICATIONS V DRIVE UNITS
Nominal Pump Rating GPM (m/hr) 8 (2) 15 (3) 30 (7) 75 (17) 100 (23) 135 (31) 135 (31) 140 (32) 200 (45) 300 (68) 500 (114) 420 (95) RPM 1800 1800 1800 780 780 640 640 520 640 520 520 420

Dimensions for V Drive UnitsSee Page 141.12. Performance Data for V Drive UnitsSee Pages 141.15 through 410.42.

Model Numbers Packed G125V H125V HL125V K125V KK125V L125V LQ125V LL125V LS125V Q125V QS125V M125V Mech. Seal G4125V H4125V HL4125V K4125V KK4125V L4125V LQ4125V LL4125V LS4125V Q4125V QS4125V M4125V

Port Size Inches 1 1 1 2 2 2 2 3 3 4 6 4

Maximum Hydrostatic Pressure PSIG (BAR) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28)

Steel-Fitted Construction Recommended Above This Viscosity SSU (cSt) 7,500 (1,650) 25,000 (5,500) 7,500 (1,650) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 25,000 (5,500) 2,500 (550) 75,000 (16,500) 7,500 (1,650) 75,000 (16,500) 25,000 (5,500)

Maximum Recommended Discharge Pressure When Handling 100 SSU Liquid At Nominal Rated Speeds PSIG 200 200 200 200 200 200 200 200 150 150 150 150

Maximum Recommended Temperature For Cataloged Pump, F. (C.) Packed 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) 300 (149) Mech. Seal 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107) 225 (107)

Approximate Shipping Weight With Valve (Less Power) Pounds (KG) 93 109 114 255 265 305 340 365 375 986 1,100 1,138 (42) (49) (52) (116) (120) (138) (154) (166) (170) (448) (499) (517)

Buna-N elastomer used in mechanical seal of Series 4125 pumps. Viton, Neoprene, and Teflon mechanical seals also available. For mechanical seal pumps on applications with viscosities above 15,000 SSU (3,300 cSt), provide details for recommendation. For maximum recommended discharge pressures when handling other viscosities and/or at other speeds, see performance curves. If suction pressure
Metric conversions are based on US measurements and rounded to the nearest whole number.

exceeds 50 PSIG (3 BAR), consult factory. Ports are suitable for use with 125# ANSI cast iron or 150# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. Nominal rating based on handling thin liquids. Standard seal can be used from -20F. to +225F. With special construction, temperatures from -60F. to +650F. can be handled with this series pumps.
Teflon Registered trademark of E.I. DuPont Company. Viton Registered trademark of DuPont Dow Elastomers L.L.C.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

141 141.8 D

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125 DIMENSIONS

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 141.2.

DIMENSIONS SERIES 125 AND 4125 UNMOUNTED PUMPS

Ports are suitable for use with 125# ANSI cast iron or 150# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe.

MODEL NO. PACKED SEAL


G125 H125 HL125 AK125 AL125 K125 KK125 L125 LQ125 LL125 LS125 Q125 M125 G4125 H4125 HL4125 AK4125 AL4125 K4125 KK4125 L4125

A
1 1 2 2 2 in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm

B
2.50 64 3.00 76 4.50 114 5.12 130 6.50 165 7.19 183 7.19 183 7.19 183 8.25 210 9.50 241

C
3.50 89 4.75 121 6.62 168 8.00 203 10.25 260 10.25 260 10.25 260 10.25 260 14.00 356 438

D
2.75 70 3.50 89 5.25 133 5.50 140 7.00 178 7.00 178 7.00 178 7.00 178 8.75 222 254

E
1.62 41 2.75 70 2.88 73 4.00 102 4.38 111 4.38 111 4.38 111 4.38 111 4.12 105 5.00 127

F
1.31 33 2.25 57 2.00 51 2.75 70 4.00 102 4.00 102 4.00 102 4.00 102 4.00 102 6.00 152

G
4.00 102 6.75 171 6.75 171 9.25 235 10.00 254 10.00 254 10.00 254 10.00 254 10.00 254 12.00 305

H
2.44 62 3.50 89 4.00 102 4.00 102 5.38 137 5.38 137 5.38 137 5.38 137 6.00 152 8.50 216

J
.34 9 .47 12 .41 10 .53 13 .53 13 .53 13 .53 13 .53 13 .69 18 .69 18

K
1.00 25 1.50 38 2.25 57 2.00 51 2.00 51 2.00 51 2.00 51 3.25 83 4.38 111 4.00 102

L
1.12 28 3.38 86 2.81 71 3.00 76 3.38 86 3.38 86 3.38 86 4.75 121 6.62 168 7.75 197

M
4.88 124 5.19 132 8.88 226 9.38 238 9.12 232 9.12 232 9.12 232 9.12 232 11.12 282 8.12 206

N
1.09 28 1.19 30 2.00 51 1.75 44 1.75 44 1.75 44 2.25 57 2.44 62 3.00 76 4.00 102

O
.31 8 .56 14 .44 11 .62 16 .62 16 .62 16 .62 16 .62 16 .75 19 1.00 25

P
.69 18 .62 16 1.00 25 .62 16 .62 16 .62 16 .62 16 .62 16 1.00 25 1.50 38

R
7.31 186 265 335 359 397 397 397 400 489 511

S
9.52 242 337 449 460 498 498 511 551 679 721

T
1.12 28 1.62 41 2.50 64 2.25 57 2.25 57 2.25 57 2.25 57 3.50 89 4.50 114 4.25 108

U
.50 13 .75 19.05 1.00 25.40 1.12 28.58 1.12 28.58 1.12 28.58 1.12 28.58 1.44 36.51 1.94 1.94

V
.12 x .06 3.05 x 1.52 .19 x .09 4.76 x 2.38 .25 x .12 6.35 x 3.18 .25 x .12 6.35 x 3.18 .25 x .12 6.35 x 3.18 .25 x .12 6.35 x 3.18 .25 x .12 6.35 x 3.18 .38 x .19 9.53 x 4.76 50 x .25 .50 x .25

W
2.69 68 2.88 73 4.80 122 5.12 130 5.38 137 5.38 137 5.38 137 5.19 132 8.19 208 8.50 216

10.44 13.25 13.18 17.68 14.12 18.12 15.62 19.62 15.62 19.62 15.62 20.12 15.75 21.69 19.25 26.75 20.12 28.38

LQ4125 2 LL4125 3 LS4125 3 Q4125 4

49.21 12.70 x 6.35 49.21 12.70 x 6.35

M4125 4

17.25 10.00

For specifications, see page 141.2.

DIMENSIONS SERIES 125 AND 4125 UNMOUNTED PUMPS QS SIZE

NOTE: Dimensions shown in parentheses are millimeters; others are inches.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125 DIMENSIONS
For specifications, see pages 141.3 through 141.5.

Section Page Issue

141 141.9 D

These dimensions are average and not for construction purposes. Certified prints on request.

DIMENSIONS SERIES 125 AND 4125 (R DRIVE) G THROUGH AL SIZE PUMPS A SIZE REDUCER UNITS

Base suitable for motor frames 56 through 184-T on Models G, H, and HL through 215-T for Models AK and AL. For motor frames 213-T and 215-T, G dimension is increased to 34.00. All other dimensions remain the same. (Base has open ends.) Does not apply to Models AK and AL. Location of pump port centerline on Models G125R and G4125R. With motor frames 182-T and smaller, use the (four) corner base anchor holes. Motor frame 184-T covers up the lower left corner anchor hole, so the hole 9.00 to the right is used. Does not apply to Models AK and AL. On Models G125R and G4125R, E dimension includes pump block. Base height is 2.94.

(Check footnote for applicability.)

MODEL NUMBER PACKED SEAL


G125R G4125R

A 1

B 2.50 64 3.00 76 4.50 114

C 2.75 70 3.50 89 5.25 133

E 3.69 94 2.94 75 102

F 229 229 406

G 737 737 991

H 38 38 35

J 1.00 25 1.00 25 1.38 35

K .56 14 .56 14 .62 16

L .12 3 2.62 67 3.19 81

M 3.75 95 4.06 103 6.80 173

N 1.81 46 2.62 67 6.00 152

9300 29.00 1.50 9.00 29.00 1.50

H125R H4125R AND AND 1 HL125R HL4125R AK125R AK4125R AND AND AL125R AL4125R

4.00 16.00 39.00 1.38

For specifications, see pages 141.3 through 141.5.

DIMENSIONS SERIES 125 AND 4125 (R DRIVE) AK THROUGH LS SIZE PUMPS B SIZE REDUCER UNITS
MODEL NUMBER PACKED SEAL
Ports are suitable for use with 125# ANSI cast iron or 150# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. With motor frames 184-T and smaller, these units are assembled on a shorter base with the following dimension changes: (F = 16, G = 39, L = 3, N = 5). Motor rails 1 high are required with 56, 143-T and 145-T frame motors. NOTE: Motor frame larger than 256-T requires larger base. Consult factory. Units available to accept 10HP, 1200 RPM maximum motor. NOTE: Motor rails 2 high are required on L through LS size units with 184-T or 4 center height motors.
AK125R AND AL125R AND KK125R L125R LQ125R LL125R LS125R AK4125R AND AL4125R AND KK4125R L4125R

A 2 2 2 in mm in mm in mm

B 4.50 114 5.12 130 165 183 183 183

C 9.50 241 9.50 241 279 279 279 279

E 102 102 102 102 102 102

F 362 362 362 362 362 362

G 1219 1219 1219 1219 1219 1219

J 35 35 35 35 35 35

K .62 16 .62 16 .62 16 .62 16 .62 16 .62 16

L 3.19 81 2.00 51 2.38 60 2.38 60 2.38 60 2.38 60

M 6.80 173 6.88 175 7.12 181 7.12 181 7.62 194 7.62 194

N 4.88 124 4.25 108 4.62 117 4.62 117 4.62 117 4.62 117

4.00 14.25 48.00 1.38 4.00 14.25 48.00 1.38

K125R K4125R

6.50 11.00 4.00 14.25 48.00 1.38 7.19 11.00 4.00 14.25 48.00 1.38 7.19 11.00 4.00 14.25 48.00 1.38 7.19 11.00 4.00 14.25 48.00 1.38

in LQ4125R 2 mm
LL4125R LS4125R

3 3

in mm in mm

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

141 141.10 D

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125

DIMENSIONS

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see pages 141.3 through 141.5.

DIMENSIONS SERIES 125 AND 4125 (R DRIVE) KK THROUGH M SIZE PUMPS (NOT FOR QS SIZE) C SIZE REDUCER UNITS
MODEL NUMBER PACKED
KK125R

SEAL
KK4125R

A 2 in mm in mm in mm in mm in mm in mm in mm

K .69 18 .69 18 .69 18 .69 18 .69 18 .69 18 .69 18

L 3.00 76 0 0 0 0 0 0 1.38 35

M 6.88 175 7.12 181 7.12 181 7.62 194 7.62 194

N 6.06 154 5.75 146 5.75 146 5.75 146 5.75 146

5.12 13.75 6.00 21.00 49.00 1.50 130 349 152 533 1245 38

L125R

L4125R

2 2 3 3 4 4

6.50 13.75 6.00 19.75 59.50 1.50 165 349 152 502 1511 38

LQ125R

LQ4125R

7.19 13.75 6.00 19.75 59.50 1.50 183 349 152 502 1511 38

LL125R

LL4125R

7.19 13.75 6.00 19.75 59.50 1.50 183 349 152 502 1511 38

LS125R

LS4125R

7.19 13.75 6.00 19.75 59.50 1.50 183 349 152 502 1511 38

Q125R

Q4125R

8.25 14.75 6.00 19.75 59.50 1.50 210 375 152 502 1511 38

5.88 11.19 5.75 73 284 146


Ports are suitable for use with 125# ANSI cast iron or 150# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe.

M125R

M4125R

9.50 16.00 6.00 19.75 59.50 1.50 241 406 152 502 1511 38

6.50 12.50 5.75 89 318 146

For specifications, see pages 141.3 through 141.5.

DIMENSIONS SERIES 125 AND 4125 QS SIZE PUMPS C SIZE REDUCER UNITS

NOTE: Dimensions shown in parentheses are millimeters; others are inches.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125 DIMENSIONS
For description, see page 141.6.

Section Page Issue

141 141.11 D

These dimensions are average and not for construction purposes. Certified prints on request.

DIMENSIONS SERIES 125 AND 4125 (D DRIVE) G SIZE PUMPS DIRECT CONNECTED UNITS

B in mm G125D
OR

D 3.50 89 3.50 89 4.50 114 5.25 133

FRAME 56 143T 145T 182T 184T 213T 215T


OR OR OR

E 1.50 38 1.50 38 1.50 38 2.94 75

F 17.50 445 20.50 521 20.50 521 25.00 635

H .75 19 .75 19 .75 19 1.00 25

J .75 19 .75 19 .75 19 1.50 38

K 8.50 216 8.50 216 8.50 216 9.00 229

L 1.88 48 1.88 48 1.88 48 1.88 48

M 3.75 95 3.75 95 3.75 95 3.75 95

P .53 13 .50 13 .50 13 .56 14

S 4.25 108 4.25 108 4.25 108 4.50 114

2.50 64 2.50 64 2.50 64 2.50 64

in mm in mm in mm

G4125D

For description, see page 141.6.

DIMENSIONS SERIES 125 AND 4125 (D DRIVE) H THROUGH AL SIZE PUMPS DIRECT CONNECTED UNITS
MODEL NUMBER PACKED SEAL A 1
H125D OR H4125D OR HL4125D

B in mm in mm in mm in mm in mm in mm in mm 3.00 76 3.00 76 3.00 76 4.50 114 4.50 114 4.50 114 4.50 114

D 3.50 89 4.50 114 5.25 133 5.25 133 5.25 133 6.25 159 7.00 178

E 1.50 38 2.94 75 2.94 75 2.94 75 2.94 75 4.00 102 4.00 102

F 20.50 521 25.00 635 25.00 635 26.00 660 29.00 737 39.00 991 39.00 991

K .50 13 .56 14 .56 14 .56 14 .56 14 .62 16 .62 16

L 1.75 44 .56 14 3.38 86 3.56 90 3.56 90 3.19 81 3.19 81

M 4.06 103 4.06 103 4.06 103 6.80 173 6.80 173 6.80 173 6.80 173

N 8.50 216 9.00 229 9.00 229 9.00 229 9.00 229 16.00 406 16.00 406

S 4.25 108 4.50 114 4.50 114 4.50 114 4.50 114 8.00 203 8.00 203

1 1 2

For motor frames 56, 143-T, and 145-T. (Base has open ends.) For motor frames 182, 182-T, 184, and 184-T. (Base has closed ends.) For motor frames 213 through 215-T. (Base has closed ends.) For motor frames 182 through 184-T. Dimension includes block under motor. (Base has open ends.) For motor frames 213 through 215-T. (Base has open ends.) For motor frames 254 through 256-T. (Base has closed ends.) For motor frames 284 through 286-T. (Base has closed ends.)

HL125D

AK125D OR AL125D

AK4125D OR AL4125D

2 2 2

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

141 141.12 D

VIKING HEAVY DUTY PUMPS


SERIES 125 AND 4125 DIMENSIONS

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 141.7.

DIMENSIONS SERIES 125 AND 4125 (V DRIVE) G SIZE PUMPS V-BELT DRIVE UNITS

NOTE: For motor frames 56 and 143-T. Maximum frame size is 143-T. D dimension for motor frame 56 is 3.50 (89 mm) less rail; for motor frame 143-T, 5.00 (127 mm) with rail. NOTE: Dimensions shown in parentheses are millimeters; others are inches.

For specifications, see page 141.7.

MODEL NUMBER PACKED


AND

DIMENSIONS SERIES 125 AND 4125 (V DRIVE) H THROUGH M SIZE PUMPS V-BELT DRIVE UNITS
A 1 2 2 2 3 3 4 4 in mm in mm in mm in mm in mm in mm in mm in mm B
3.00 76 5.12 130 650 165 7.19 183 7.19 183 7.19 183 8.25 210 9.50 241

SEAL
AND

C
9.25 235 13.81 351 15.31 389 15.31 389 15.31 389 15.31 389 21.25 540 22.50 572

E
1.75 44 3.25 83 3.25 83 3.25 83 3.25 83 3.25 83 6.00 152 6.00 152

F
14.75 375 17.00 432 17.00 432 17.00 432 17.00 432 17.00 432 21.00 533 21.00 533

G
23.75 603 28.75 730 28.75 730 28.75 730 28.75 730 28.75 730 49.00 1245 49.00 1245

J
.75 19 1.00 25 1.00 25 1.00 25 1.00 25 1.00 25 1.50 38 1.50 38

K
.50 13 .50 13 .50 13 .50 13 .50 13 .50 13 .81 21 .81 21

L
4.88 124 2.50 64 2.25 57 2.25 57 2.25 57 1.06 27 2.75 70 2.12 54

M
4.06 103 6.88 175 7.12 181 7.12 181 7.62 194 7.62 194 11.19 284 12.50 318

N
4.25 108 5.25 133 5.25 133 5.25 133 5.25 133 5.25 133 8.50 216 8.50 216

H125V H4125V HL125V HL4125V K125D K4125V KK125D KK4125V


L125V AND AND

L4125V

LQ125V

LQ4125V

LL125V

LL4125V

LS125V Q125V

LS4125V

Ports are suitable for use with 125# ANSI cast iron or 150# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. Base dimensions correct for all motors. Base dimensions correct through frame 215-T motors and 19 OD sheaves. Larger motors and/or 25 OD sheaves require larger base. QS size pump drawing available on request.

Q4125V

M125V

M4125V

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005