CONTROL VALVE DATA SHEET

1 2 1 2 3 4 5 6 7 PROCESS DATA RELEVANT FOR CONTROL SELECTION 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Kv / SPL 32 33 34 35 36 37 38 39 40 41 VALVE BODY ASSEMBLY 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 Remarks: Seat style Trim coating Breakaway force/torque Leakage specification IEC 60534-4 Class: Packing Steam jacket:
adjustable no self adj. yes; PN metallic soft seated

Tag. No. Mfr. Seril No.

3 Location Service Haz. area class Ambient temp. Allowable sound pressure level Upstream pipe NPS

6 57 58

7 MFR Pneumatic Style Size Travel/angle ACTUATOR Supply press. Bench range Stroking time Air connection Other actuator Act. force/torque min manual override limit stops MFR Input signal Valve opene at POSITIONER Valve closed at Style Characteristic Air connection Accessories Reduction of haz. Digital comm. POS.IND.SWITCH MFR Switch type Switching pos. Switch acting Reduction of haz. Assembly MFR SOLENOID VALVE Valve type
2 - way mech. closed make
HART

8 Model
diaphragm sprg opposed piston double act.

air spring

IP Code min.

SIL max. dB(A)

59 60 61 62 63 64

eff area

cm

SCH SCH Material


thermal

t(mm) t(mm)

min

max

bar g bar g

Downstream pipe NPS Pipe class Pipe insulation Design Press Pipe connection upstr. Process Fluid Upstream cond. Special fluid properties: Flow rate Inlet press. Outlet press. Temperature Inlet density P1 P2 T1 1 or M
Liquid

min

max

s frequency /min

acoustic

65 C 66 67 68

bar

Design Temp. downst.

electr.

hydraulic

manual

max
no mechanic
% travel

unit
hydraulic
open

Steam

Gas

2ph.

69 70

closed

Model
pneumatic electric digital-> 111

Min.

Norm.

Max.

Unit

71 72 73 74 75 76 77 78 79

single act. linear


eq%

double act.
modified

Electr. connect.
bypass intr. safe
FF

Vapour pressure Pv Critical pressure Pc Viscosity Specific heat ratio (k=cp/cv) Compressibility factor Z1 Gas/vapour mass fract. Shutoff press. Air supply Power/Signal fail pos. P1 min.
open

gauges flamepr. enclosure


Profibus

..

Zn

80 81

Model
proximity % travel break
flamepr. enclosure built-in

.
open

% P2 max.
close

82 83 84 85 86

Unit Unit
remain

intr. safe
external

Model
3-way open closed 4-way hold

Calc. Kv Valve X
T

87 ----dB(A) Model
globe (straight) FTO angle FTC 3-way manuf.std.

88 89 90 91 92 93 94 95

De-energ.: control valve


digital operated ->111

Valve FL Perdicted SPL MFR Body type Flow direction Pressure rating Nominal size End Conn.
flgd. flangess. welded

Air connection Electrical data Reduction of haz. V

Port size Hz W

intr.safe

flamepr. enclosure

Air set MFR. with filter I/P converter MFR.

Model
with gauge

thrd.

96 97 OTHERS

Model Output signal Model


electr.
pneum.

Input signal
Booster MFR. Pos. feedback Lockup relais MFR Air trip valve MFR.

Extended connection Bonnet type


standard extended bellows

98 99 100

digital

Model Model Matl. Matl.


chem. and mech. test surface
volume

Body/bonnet material Trim Charakteristic Plug(disc) mat. Guide(cage) mat.


linear standard low noise eq. percent multistage

101 102 103 104 SPECIAL REQUIREMENTS 105 106 107 108 max. allowed 109 110 mat. mat. 111 112

Air tubing Air fittings Test certificate(s) NDE Examination Acceptance Citeria Parts to be tested

stem mat. seat mat.

body / bonet

bolts / nuts

trim

Dig. Communication: Software drivers:

Project Plant Rev. Date Name Date Name P.O. No.

Dwg. ref No. Mt. req. No. Item No. Qty

Polna corp. s.r.o. Oldichovice 738, 739 61 Tinec-Oldichovice, tel.: +420 558 321 088-9, fax: +420 558 338 330, e-mail: info@polnacorp.eu, www.polnacorp.eu