Вы находитесь на странице: 1из 8

T.O.S. +89.

65m
LEVEL 17
F.1
G-1 G-1
2
01
1:20
TYPICAL PARTIAL PLAN @ LEVEL 09-40
03
1:20
TYPICAL PARTIAL SECTION
G.1
G-3
G-3
G-3
G-3
T.O.S. +94.95m
LEVEL 18
W-01
T.O.S. +86.35m
LEVEL 16
G-1 G-1 G-3
G-3
G-3
740
32
250
250
740
32
3" EXTRUDED ALUM
AIRFOIL BLADE, TYP.
CUSTOM TAPERED ALUM
OUTRIGGER PLATE, TYP.
STEEL PLATE S/S H/H
BOLTS, TYP.
N
KEY PLAN
P
lo
t D
a
te
: 3
0
J
u
n
e
2
0
1
1
H
a
n
d
e
l A
s
s
o
c
ia
te
s
L
td

SHANGR/-LA AT
THE FORT, MAN/LA
FORT BONIFACIO
ARCHITECTS CO.
GF & PARTNERS
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8946281 to 85 FAX 63-2-8921861 E-MAIL: postmaster@gfparchitects.com
XAVIER ANTONIO J . GARCIA TEODORO H. NARCISO
TEOFILO A. SANTIAGO J R. ANNETTE F. GADDI-LIGANOR
CONSULTING ENGINEERS
DCCD ENGINEERING
112 SOL BUILDING, AMORSOLO STREET, LEGASPI VILLAGE, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8924586 TO 97 FAX 63-2-8182142 E-MAIL info@dccd.com
CORPORATION
IM MARTINEZ
UNIT 410 FEDMAN SUITES CONDOMINIUMBLDG. NO. 199-201 SALCEDO ST. LEGASPI VILLAGE
TELEPHONE 632-8932898 FAX 632-8925188 E-MAIL immce@pldtdsl.net
MAKATI CITY 1229 PHILIPPINES
SHANGRI-LA HOTEL, INC.
CONSULTING ENGINEERS
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL: pmt.slfm@shangri-la.com
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL:
20th FLOOR EASTERN CENTRAL PLAZA 3 YIU HING ROAD SHAUKEIWAN HONG KONG
RIDER LEVETT BUCKNALL
LTD.
HANDEL ASSOCIATES
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
CONSULTING ENGINEERS LTD
DESIMONE
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
J.P.R SDN. BHD.
12TH FLOOR, PENAS TOWER, 488A, J ALAN BURMA 10350, PENANG, MALAYSIA
A R C H I T E C T
:
:
:
:
ANNETTE F. GADDI-LIGANOR
SUPERSTRUCTURE ADVANCE TENDER SET
A421
TOWER WALL TYPES -
TYPE 1
EXTERIOR WALL TYPES
EXTERIOR MATERIALS
G-1
G-3
L-1
MTL-1
G-5
1. PROVIDE OPERABLE VENTS/WINDOWS FOR NATURAL VENTILATION AS MANDATED BY
APPLICABLE BUILDING CODES. THE LOCATION FOR OPERABLE VENTS/WINDOWS &
SIZES MAY CHANGE PER DESIGN DEVELOPMENT OF FACADE.
2. REFER TO DRAWING G001 FOR GENERAL EXTERIOR ENVELOPE NOTES.
3. REFER TO SERIES A1.00 FOR BUILDING PLANS.
4. REFER TO SERIES A4.00 FOR EXTERIOR WALL SECTIONS, TYPES AND DETAILS.
5. REFER TO SERIES A8.00 FOR GLASS PANELS SIZES.
6. LIGHTENING GROUNDING TO BE WIRED TO CURTAIN WALL. WIRING TO BE TAKEN TO
NEAREST COLUMN & CONDUIT TO RUN DOWN TO BUILDING FOUNDATION.
7. PROVIDE BUILT IN ELECTRIC SENSOR AT HOTEL RESIDENCE OPERABLE WINDOWS.
SENSOR IS TO BE HARDWIRED TO JBOX FOR CONNECTION TO FANCOIL UNIT. REFER
TO MEP DRAWINGS FOR DETAILS AND SPECIFICATION.
8. BACK-UP WALL SHOWN FOR DESIGN INTENT AND COORDINATION ONLY. REFER TO
STRUCTURAL CONSULTANT'S DRAWINGS FOR DIMENSION, DETAILS, AND MATERIAL
FOR BACK-UP WALL.
GENERAL NOTES
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT OR PRESSURE PLATES AS INDICATED
ON ELEVATIONS WITH;
1) 150 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS. (SEE DETAILED
DRAWINGS FOR PROFILE)
2) 740mm DEEP SUNSHADE DEVICE MECHANICALLY ATTACHED TO MULLIONS.
REINFORCE MULLIONS AS REQD.
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT AT HORIZONTAL MULLIONS AND
CAPTURED MULLIONS AT VERTICAL MULLIONS WITH ;
1) 200 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
VERTICAL MULLION AS INDICATED ON ELEVATIONS.
2) 100 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS.
DIMENSIONED STONE MASONRY FOR EXTERIOR CLADDING. STONE PANELS
ARE INDEPENDENTLY SUPPORTED AND ANCHORED TO BACKUP WALL WITH
NON-CORROSIVE SUPPORTS. 8mm -12mm OPEN JOINTS BETWEEN STONE
PANELS. NON-STAINNG, NON-SHRINK SEALANT AT MASONRY OPENING
BETWEEN METAL FRAME AND STONE PANELS. SILL, JAMB, SOFFIT AND SPECIAL
PROFILED PANELS MAY BE REQUIRED FOR OPENINGS IN THE FIELD OF STONE.
SEAL BACKSIDE OF STONE WITH MANUFACTURED APPROVED NON-STAINING
SEALER. ALL EXPOSED SURFACES OF THE STONE TO THE VIEW TO BE
FINISHED. FACTORY FINISHED DRIP EDGE AT THE BOTTOM STONE PANEL AT
SOFFITS AND LINTELS. PROVIDE STAINLESS STEEL OR METAL FLASHING AT
EVERY OTHER CONTINUOUS HORIZONTAL JOINT.
VISION GLASS: IGU WITH LOW-e COAT (2nd surface)
Tower Glass Color & Coating: TO BE DECIDED
Podium Glass Color & Coating: TO BE DECIDED
SPANDREL GLASS INDICATION ON THE DRAWINGS.
Glass coating, Make up & Color: Same as G-1
Paint Color: TO BE DECIDED
PILKINGTON SYSTEM (or approved equal)GLASS PANELS FOR ICONIC
RETAIL AREA
Glass Make Up: Per manufacturer's design recommendation
G-6
G-2
SHADOW BOX INDICATION ON THE DRAWINGS
Vision Glass, coating, Make up & Color: Same as G-1
MTL-2
G-4
STOREFRONT GLASS PANELS:
WALL TYPE - 6 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED
G-7
WALL TYPE - 7 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO ELEVATIONS)
Glass Color, Coating & FRIT pattern: TO BE DECIDED
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS AND SHADOW BOXES ATTACHED
WITH STRUCTURAL SEALANT AT ALL 4 SIDES.
DESIGN BUILT STICK SYSTEM CURTAIN WALL INCLUDING EXTRUDED ALUM.
MULLIONS, METAL PANELS, LOW-e IGU PANELS ATTACHED WITH STRUCTURAL
SEALANT AND CAPTURED MULLIONS. CONNECT WITH W 02 AND W03 AS
REQUIRED. (ADDITIONAL MECHANICAL ATTACHMENT FOR METAL PANEL
SUGGESTED.)
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. HORIZONTAL MULLIONS ANCHORED
WITH SHEAR BLOCKS OR STEEL INSERTS. GLASS PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED METAL FACIA
PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER SLAB EDGE AND
PERIMETER BEAM.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. LOW-e IGUs PANELS AND IGUs WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRITT PATTERN AT 2nd & 3rd SURFACE
ATTACHED WITH STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED
METAL FACIA PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER
SLAB EDGE AND PERIMETER BEAM.
30mm THK. (nom.)TEMPERED GLASS PANEL (1.5m WIDE x 10m TALL) SET IN
STAINLESS STEEL CHANNELS ANCHORED AT TOP & BOTTOM SET ON HIGH
DENSITY SETTING BLOCKS, PRE-FORMED GASKET AT INTERIOR AND
PRE-FORMED GASKET WITH CLEAR SILICON SEALANT AT EXTERIOR.
Lateral brace: GLASS FINS SET IN STAINLESS STEEL CHANNEL
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO HANGER - 10m TALL - BY
FULLY ENCLOSED STEEL SUPPORT AND STEEL ANCHORS. IGU PANELS WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRIT PATTERN AT 2nd & 3rd SURFACE
WITH AND WITHOUT SHADOW BOXES ATTACHED WITH STRUCTURAL SEALANT
AT ALL 4 SIDES. INTERMEDIATE HORIZONTAL MULLIONS FOR GLAZING SUPPORT
ONLY. INDEPENDENTLY SUPPORTED NON IGU PANELS INSTALLED WITHIN THE
SYSTEM AS INDICATED ON ELEVATION.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS, LOW-e PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES.
G-8
WALL TYPES - 8 and 9 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED G-9
DESIGN BUILT ALUM. STOREFRONT WITH CUSTOM PROFILED MULLIONS
SUPPORTED SLAB TO SLAB/SUPPORT FRAMING BY FULLY ENCLOSED STEEL
SUPPORT AND STEEL ANCHORS, GLASS PANELS ATTACHED WITH STRUCTURAL
SEALANT AT HORIZONTAL MULLIONS AND CAPTURED AT VERTICAL MULLIONS,
GRANITE BASE AND LOUVERS AT TOP. ALUM FRAMED ENTRANCES WITH FLOOR
CLOSURES AS INDICATED ON ELEVATIONS.
DESIGN BUILT PILKINGTON PLANAR (or approved equal) GLAZING SYSTEM WITH
LOUVERS AND ENTRANCES. GLAZING CONNECTORS AND GLASS PANELS PER
MANUFACTURER'S DETAILS.
G-10 GLASS PANELS FOR BALCONY & TERRACE RAILING.
G-11
WALL TYPE - 11 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO Drawing A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
TYPICAL METAL FINISHES NOTE:
1. PAINT DIS-SIMILAR METALS TO AVOID GALVANIC ACTION.
2. SEAL ALL SCREW PENETRATIONS. ALL METAL ATTACHMENTS SHALL BE
CONCEALED IN PUBLIC TRAFFIC AREAS AND SPACES.
3. ALL ALUM SURFACES EXPOSE TO WEATHER SHALL BE 70% (3 coat) AND
INTERIOR SURFACES SHALL BE 50% (2 coat) KYNAR - or approved equal - FINISH.
4. WELD BRACING ANGLES OR SECONDARY FRAMING AT THE BACK OF METAL
PANEL TO AVOID OIL CANNING.
5. ALL METAL SURFACE EXPOSE TO VIEW SHALL BE FINISHED SAME INCLUDING
BUT NOT LIMITED TO REVEALS, RETURNS & EDGES
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE WITH 50mm (min.) INSULATION WITH;
1) FACTORY APPLIED VAPOR BARRIER AT INDICATED LOCATIONS.
2) FACTORY APPLIED VAPOR BARRIER AND METAL PANEL AT
INDICATED LOCATION.
CUSTOM PROFILE EXTRUSIONS OR BENT ALUM INCLUDING BUT NOT
LIMITED TO TRIMS, COPINGS, DRIP EDGES, RAILING POSTS.
THICKNESS & SIZES AS INDICATED ON DRAWINGS.
MTL-3 740 mm DEEP SUN SHADE AT TOWER.
3mm THK. (nom.) ALUM. METAL BENT TO FORM 1.0m x 5.1m (nom.)
PANEL WITH 50mm (min.) INSULATION & FACTORY APPLIED VAPOR
BARRIER.
MTL-4
MTL-6
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE FOR EXTERIOR CLADDING, SOFFITS, COLUMN
COVERS AND MISC.
L-2
ST-1
ST-2
ST-3
STORM CLASS ALUM LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING: 1.0m x 2.0m (nom.) TYPICAL STONE PANEL,
INDEPENDENTLY SUPPORTED, OPEN JOINTS
ALT 1: 100mm THK. (nom., min.) HONED FINISH FRENCH LIMESTONE
ALT2: 50 mm THK. (nom.) HONED FINISH FRENCH LIMESTONE PANELS
ON 100mm THK. (nom.) CONC. BACK UP PANELS
ALT3: 30mm - 50mm THK. (nom.) GRANITE PANELS
ALT4: 125mm THK. (nom.) PRECAST PANELS
L-4
ZEROSITELINE FLUSH ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-5
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-6
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING AT GROUND LEVEL: 0.35m x 2.5m (nom.) PANEL
Stone: TO BE DECIDED
30mm THK. (nom.) 1.5m LONG POLISHED GRANITE BASE AT WALL
TYPES - SF01,SF02 & SF03.
150mm (min.) - 350mm (max.) HEIGHT OF BASE ABOVE FINISHED
FLOORING.
Stone color: TO BE DECIDED
G-7a NON IGU GLASS PANELS AT Jr. BALLROOM PRE-FUNCTION AREA
G-7b
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO DRAWING A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
REFER TO EXTERIOR WALL CONSULTANT'S SPECIFICATION FOR
GLASS MAKE UP, DETAILS AND PERFORMANCE INFORMATION.
G-11a
NON IGU GLASS PANELS AT MAIN BALLROOM PRE-FUNCTION
AREA
COMPOSITE SYSTEM OF STICK BUILT CURTAIN WALL AND ALUM. FRAMED
PUNCHED WINDOWS WITH CUSTOM PROFILED EXTERIOR TRIMS INSTALLED
WITHIN FIELD FOR STONE AND METAL PANELS.
ST-4
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT WALL TYPE - W08
Stone type & finish: TO BE DECIDED
ST-5
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT LOCATIONS INDICATED ON ELEVATIONS.
Stone type & finish: TO BE DECIDED
SC-1
50mm - 75mmTHK. (nom.) STUCCO, THICKNESS TO DEPEND ON
LOCATION AND FINISH.
Finish & Color: TO BE DECIDED
01/24/2011 2 01/24/2011 2
02
02
07/01/2011 4
D.1 2
3
W-01
MTL-3
MTL-2
MTL-3
MTL-2
1
6
9
0
9
1
3
6
0
0
1
5
0
4
3
2
6
9
1
8
5
0
177
1089 600
177
388
300
600 1149
1832
1
6
1
5
3
0
1
7
6
5
1
2 4
8
450 510
3360
LIQUID APPLIED MOISTURE
BARRIER AND WATER PROOFING
LIQUID APPLIED
MOISTURE
BARRIER AND
WATER PROOFING
CONCRETE CURB
AT ALL INTERIOR
BALCONY WALLS
W/ LIQ. APPLIED
WATER PROOFING
G-1 GLASS IN
WINDOW FRAME
(STICK SYSTEM AT
ALL INTERIOR
BALCONY WALLS)
INSULATED MTL-1
PANEL WITH
VAPOR BARRIER IN
WINDOW FRAME
MTL-1 PANELS (NO INSULATION)
MOUNTED ON GALV. METAL STUDS
MTL-1
MTL-1
MTL-X
MTL-X
ST-1
A442
6
N
KEY PLAN
P
lo
t D
a
te
: 3
0
J
u
n
e
2
0
1
1
H
a
n
d
e
l A
s
s
o
c
ia
te
s
L
td

SHANGR/-LA AT
THE FORT, MAN/LA
FORT BONIFACIO
ARCHITECTS CO.
GF & PARTNERS
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8946281 to 85 FAX 63-2-8921861 E-MAIL: postmaster@gfparchitects.com
XAVIER ANTONIO J . GARCIA TEODORO H. NARCISO
TEOFILO A. SANTIAGO J R. ANNETTE F. GADDI-LIGANOR
CONSULTING ENGINEERS
DCCD ENGINEERING
112 SOL BUILDING, AMORSOLO STREET, LEGASPI VILLAGE, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8924586 TO 97 FAX 63-2-8182142 E-MAIL info@dccd.com
CORPORATION
IM MARTINEZ
UNIT 410 FEDMAN SUITES CONDOMINIUMBLDG. NO. 199-201 SALCEDO ST. LEGASPI VILLAGE
TELEPHONE 632-8932898 FAX 632-8925188 E-MAIL immce@pldtdsl.net
MAKATI CITY 1229 PHILIPPINES
SHANGRI-LA HOTEL, INC.
CONSULTING ENGINEERS
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL: pmt.slfm@shangri-la.com
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL:
20th FLOOR EASTERN CENTRAL PLAZA 3 YIU HING ROAD SHAUKEIWAN HONG KONG
RIDER LEVETT BUCKNALL
LTD.
HANDEL ASSOCIATES
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
CONSULTING ENGINEERS LTD
DESIMONE
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
J.P.R SDN. BHD.
12TH FLOOR, PENAS TOWER, 488A, J ALAN BURMA 10350, PENANG, MALAYSIA
A R C H I T E C T
:
:
:
:
ANNETTE F. GADDI-LIGANOR
SUPERSTRUCTURE ADVANCE TENDER SET
A421A
TOWER WALL TYPES -
TYPE 1 WITH BALCONY
EXTERIOR WALL TYPES
EXTERIOR MATERIALS
G-1
G-3
L-1
MTL-1
G-5
1. PROVIDE OPERABLE VENTS/WINDOWS FOR NATURAL VENTILATION AS MANDATED BY
APPLICABLE BUILDING CODES. THE LOCATION FOR OPERABLE VENTS/WINDOWS &
SIZES MAY CHANGE PER DESIGN DEVELOPMENT OF FACADE.
2. REFER TO DRAWING G001 FOR GENERAL EXTERIOR ENVELOPE NOTES.
3. REFER TO SERIES A1.00 FOR BUILDING PLANS.
4. REFER TO SERIES A4.00 FOR EXTERIOR WALL SECTIONS, TYPES AND DETAILS.
5. REFER TO SERIES A8.00 FOR GLASS PANELS SIZES.
6. LIGHTENING GROUNDING TO BE WIRED TO CURTAIN WALL. WIRING TO BE TAKEN TO
NEAREST COLUMN & CONDUIT TO RUN DOWN TO BUILDING FOUNDATION.
7. PROVIDE BUILT IN ELECTRIC SENSOR AT HOTEL RESIDENCE OPERABLE WINDOWS.
SENSOR IS TO BE HARDWIRED TO JBOX FOR CONNECTION TO FANCOIL UNIT. REFER
TO MEP DRAWINGS FOR DETAILS AND SPECIFICATION.
8. BACK-UP WALL SHOWN FOR DESIGN INTENT AND COORDINATION ONLY. REFER TO
STRUCTURAL CONSULTANT'S DRAWINGS FOR DIMENSION, DETAILS, AND MATERIAL
FOR BACK-UP WALL.
GENERAL NOTES
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT OR PRESSURE PLATES AS INDICATED
ON ELEVATIONS WITH;
1) 150 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS. (SEE DETAILED
DRAWINGS FOR PROFILE)
2) 740mm DEEP SUNSHADE DEVICE MECHANICALLY ATTACHED TO MULLIONS.
REINFORCE MULLIONS AS REQD.
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT AT HORIZONTAL MULLIONS AND
CAPTURED MULLIONS AT VERTICAL MULLIONS WITH ;
1) 200 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
VERTICAL MULLION AS INDICATED ON ELEVATIONS.
2) 100 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS.
DIMENSIONED STONE MASONRY FOR EXTERIOR CLADDING. STONE PANELS
ARE INDEPENDENTLY SUPPORTED AND ANCHORED TO BACKUP WALL WITH
NON-CORROSIVE SUPPORTS. 8mm -12mm OPEN JOINTS BETWEEN STONE
PANELS. NON-STAINNG, NON-SHRINK SEALANT AT MASONRY OPENING
BETWEEN METAL FRAME AND STONE PANELS. SILL, JAMB, SOFFIT AND SPECIAL
PROFILED PANELS MAY BE REQUIRED FOR OPENINGS IN THE FIELD OF STONE.
SEAL BACKSIDE OF STONE WITH MANUFACTURED APPROVED NON-STAINING
SEALER. ALL EXPOSED SURFACES OF THE STONE TO THE VIEW TO BE
FINISHED. FACTORY FINISHED DRIP EDGE AT THE BOTTOM STONE PANEL AT
SOFFITS AND LINTELS. PROVIDE STAINLESS STEEL OR METAL FLASHING AT
EVERY OTHER CONTINUOUS HORIZONTAL JOINT.
VISION GLASS: IGU WITH LOW-e COAT (2nd surface)
Tower Glass Color & Coating: TO BE DECIDED
Podium Glass Color & Coating: TO BE DECIDED
SPANDREL GLASS INDICATION ON THE DRAWINGS.
Glass coating, Make up & Color: Same as G-1
Paint Color: TO BE DECIDED
PILKINGTON SYSTEM (or approved equal)GLASS PANELS FOR ICONIC
RETAIL AREA
Glass Make Up: Per manufacturer's design recommendation
G-6
G-2
SHADOW BOX INDICATION ON THE DRAWINGS
Vision Glass, coating, Make up & Color: Same as G-1
MTL-2
G-4
STOREFRONT GLASS PANELS:
WALL TYPE - 6 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED
G-7
WALL TYPE - 7 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO ELEVATIONS)
Glass Color, Coating & FRIT pattern: TO BE DECIDED
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS AND SHADOW BOXES ATTACHED
WITH STRUCTURAL SEALANT AT ALL 4 SIDES.
DESIGN BUILT STICK SYSTEM CURTAIN WALL INCLUDING EXTRUDED ALUM.
MULLIONS, METAL PANELS, LOW-e IGU PANELS ATTACHED WITH STRUCTURAL
SEALANT AND CAPTURED MULLIONS. CONNECT WITH W 02 AND W03 AS
REQUIRED. (ADDITIONAL MECHANICAL ATTACHMENT FOR METAL PANEL
SUGGESTED.)
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. HORIZONTAL MULLIONS ANCHORED
WITH SHEAR BLOCKS OR STEEL INSERTS. GLASS PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED METAL FACIA
PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER SLAB EDGE AND
PERIMETER BEAM.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. LOW-e IGUs PANELS AND IGUs WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRITT PATTERN AT 2nd & 3rd SURFACE
ATTACHED WITH STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED
METAL FACIA PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER
SLAB EDGE AND PERIMETER BEAM.
30mm THK. (nom.)TEMPERED GLASS PANEL (1.5m WIDE x 10m TALL) SET IN
STAINLESS STEEL CHANNELS ANCHORED AT TOP & BOTTOM SET ON HIGH
DENSITY SETTING BLOCKS, PRE-FORMED GASKET AT INTERIOR AND
PRE-FORMED GASKET WITH CLEAR SILICON SEALANT AT EXTERIOR.
Lateral brace: GLASS FINS SET IN STAINLESS STEEL CHANNEL
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO HANGER - 10m TALL - BY
FULLY ENCLOSED STEEL SUPPORT AND STEEL ANCHORS. IGU PANELS WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRIT PATTERN AT 2nd & 3rd SURFACE
WITH AND WITHOUT SHADOW BOXES ATTACHED WITH STRUCTURAL SEALANT
AT ALL 4 SIDES. INTERMEDIATE HORIZONTAL MULLIONS FOR GLAZING SUPPORT
ONLY. INDEPENDENTLY SUPPORTED NON IGU PANELS INSTALLED WITHIN THE
SYSTEM AS INDICATED ON ELEVATION.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS, LOW-e PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES.
G-8
WALL TYPES - 8 and 9 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED G-9
DESIGN BUILT ALUM. STOREFRONT WITH CUSTOM PROFILED MULLIONS
SUPPORTED SLAB TO SLAB/SUPPORT FRAMING BY FULLY ENCLOSED STEEL
SUPPORT AND STEEL ANCHORS, GLASS PANELS ATTACHED WITH STRUCTURAL
SEALANT AT HORIZONTAL MULLIONS AND CAPTURED AT VERTICAL MULLIONS,
GRANITE BASE AND LOUVERS AT TOP. ALUM FRAMED ENTRANCES WITH FLOOR
CLOSURES AS INDICATED ON ELEVATIONS.
DESIGN BUILT PILKINGTON PLANAR (or approved equal) GLAZING SYSTEM WITH
LOUVERS AND ENTRANCES. GLAZING CONNECTORS AND GLASS PANELS PER
MANUFACTURER'S DETAILS.
G-10 GLASS PANELS FOR BALCONY & TERRACE RAILING.
G-11
WALL TYPE - 11 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO Drawing A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
TYPICAL METAL FINISHES NOTE:
1. PAINT DIS-SIMILAR METALS TO AVOID GALVANIC ACTION.
2. SEAL ALL SCREW PENETRATIONS. ALL METAL ATTACHMENTS SHALL BE
CONCEALED IN PUBLIC TRAFFIC AREAS AND SPACES.
3. ALL ALUM SURFACES EXPOSE TO WEATHER SHALL BE 70% (3 coat) AND
INTERIOR SURFACES SHALL BE 50% (2 coat) KYNAR - or approved equal - FINISH.
4. WELD BRACING ANGLES OR SECONDARY FRAMING AT THE BACK OF METAL
PANEL TO AVOID OIL CANNING.
5. ALL METAL SURFACE EXPOSE TO VIEW SHALL BE FINISHED SAME INCLUDING
BUT NOT LIMITED TO REVEALS, RETURNS & EDGES
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE WITH 50mm (min.) INSULATION WITH;
1) FACTORY APPLIED VAPOR BARRIER AT INDICATED LOCATIONS.
2) FACTORY APPLIED VAPOR BARRIER AND METAL PANEL AT
INDICATED LOCATION.
CUSTOM PROFILE EXTRUSIONS OR BENT ALUM INCLUDING BUT NOT
LIMITED TO TRIMS, COPINGS, DRIP EDGES, RAILING POSTS.
THICKNESS & SIZES AS INDICATED ON DRAWINGS.
MTL-3 740 mm DEEP SUN SHADE AT TOWER.
3mm THK. (nom.) ALUM. METAL BENT TO FORM 1.0m x 5.1m (nom.)
PANEL WITH 50mm (min.) INSULATION & FACTORY APPLIED VAPOR
BARRIER.
MTL-4
MTL-6
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE FOR EXTERIOR CLADDING, SOFFITS, COLUMN
COVERS AND MISC.
L-2
ST-1
ST-2
ST-3
STORM CLASS ALUM LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING: 1.0m x 2.0m (nom.) TYPICAL STONE PANEL,
INDEPENDENTLY SUPPORTED, OPEN JOINTS
ALT 1: 100mm THK. (nom., min.) HONED FINISH FRENCH LIMESTONE
ALT2: 50 mm THK. (nom.) HONED FINISH FRENCH LIMESTONE PANELS
ON 100mm THK. (nom.) CONC. BACK UP PANELS
ALT3: 30mm - 50mm THK. (nom.) GRANITE PANELS
ALT4: 125mm THK. (nom.) PRECAST PANELS
L-4
ZEROSITELINE FLUSH ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-5
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-6
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING AT GROUND LEVEL: 0.35m x 2.5m (nom.) PANEL
Stone: TO BE DECIDED
30mm THK. (nom.) 1.5m LONG POLISHED GRANITE BASE AT WALL
TYPES - SF01,SF02 & SF03.
150mm (min.) - 350mm (max.) HEIGHT OF BASE ABOVE FINISHED
FLOORING.
Stone color: TO BE DECIDED
G-7a NON IGU GLASS PANELS AT Jr. BALLROOM PRE-FUNCTION AREA
G-7b
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO DRAWING A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
REFER TO EXTERIOR WALL CONSULTANT'S SPECIFICATION FOR
GLASS MAKE UP, DETAILS AND PERFORMANCE INFORMATION.
G-11a
NON IGU GLASS PANELS AT MAIN BALLROOM PRE-FUNCTION
AREA
COMPOSITE SYSTEM OF STICK BUILT CURTAIN WALL AND ALUM. FRAMED
PUNCHED WINDOWS WITH CUSTOM PROFILED EXTERIOR TRIMS INSTALLED
WITHIN FIELD FOR STONE AND METAL PANELS.
ST-4
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT WALL TYPE - W08
Stone type & finish: TO BE DECIDED
ST-5
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT LOCATIONS INDICATED ON ELEVATIONS.
Stone type & finish: TO BE DECIDED
SC-1
50mm - 75mmTHK. (nom.) STUCCO, THICKNESS TO DEPEND ON
LOCATION AND FINISH.
Finish & Color: TO BE DECIDED
2 01/24/2011 2
07/01/2011 4
T.O.S. +178.2m
LEVEL 40M
A422
2
H.1
01
1:20
PARTIAL PLAN AT LEVEL 40M
H.1
02
1:20
TYPICAL PARTIAL PLAN @ LEVEL 9-40, 41-60
MTL-1
MTL-2
MTL-X
MTL-1
04
1:05
TYPICAL MULLION PLAN DETAIL
N
KEY PLAN
P
lo
t D
a
te
: 3
0
J
u
n
e
2
0
1
1
H
a
n
d
e
l A
s
s
o
c
ia
te
s
L
td

SHANGR/-LA AT
THE FORT, MAN/LA
FORT BONIFACIO
ARCHITECTS CO.
GF & PARTNERS
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8946281 to 85 FAX 63-2-8921861 E-MAIL: postmaster@gfparchitects.com
XAVIER ANTONIO J . GARCIA TEODORO H. NARCISO
TEOFILO A. SANTIAGO J R. ANNETTE F. GADDI-LIGANOR
CONSULTING ENGINEERS
DCCD ENGINEERING
112 SOL BUILDING, AMORSOLO STREET, LEGASPI VILLAGE, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8924586 TO 97 FAX 63-2-8182142 E-MAIL info@dccd.com
CORPORATION
IM MARTINEZ
UNIT 410 FEDMAN SUITES CONDOMINIUMBLDG. NO. 199-201 SALCEDO ST. LEGASPI VILLAGE
TELEPHONE 632-8932898 FAX 632-8925188 E-MAIL immce@pldtdsl.net
MAKATI CITY 1229 PHILIPPINES
SHANGRI-LA HOTEL, INC.
CONSULTING ENGINEERS
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL: pmt.slfm@shangri-la.com
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL:
20th FLOOR EASTERN CENTRAL PLAZA 3 YIU HING ROAD SHAUKEIWAN HONG KONG
RIDER LEVETT BUCKNALL
LTD.
HANDEL ASSOCIATES
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
CONSULTING ENGINEERS LTD
DESIMONE
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
J.P.R SDN. BHD.
12TH FLOOR, PENAS TOWER, 488A, J ALAN BURMA 10350, PENANG, MALAYSIA
A R C H I T E C T
:
:
:
:
ANNETTE F. GADDI-LIGANOR
SUPERSTRUCTURE ADVANCE TENDER SET
A422
TOWER WALL TYPES -
TYPE 2
EXTERIOR WALL TYPES
EXTERIOR MATERIALS
G-1
G-3
L-1
MTL-1
G-5
1. PROVIDE OPERABLE VENTS/WINDOWS FOR NATURAL VENTILATION AS MANDATED BY
APPLICABLE BUILDING CODES. THE LOCATION FOR OPERABLE VENTS/WINDOWS &
SIZES MAY CHANGE PER DESIGN DEVELOPMENT OF FACADE.
2. REFER TO DRAWING G001 FOR GENERAL EXTERIOR ENVELOPE NOTES.
3. REFER TO SERIES A1.00 FOR BUILDING PLANS.
4. REFER TO SERIES A4.00 FOR EXTERIOR WALL SECTIONS, TYPES AND DETAILS.
5. REFER TO SERIES A8.00 FOR GLASS PANELS SIZES.
6. LIGHTENING GROUNDING TO BE WIRED TO CURTAIN WALL. WIRING TO BE TAKEN TO
NEAREST COLUMN & CONDUIT TO RUN DOWN TO BUILDING FOUNDATION.
7. PROVIDE BUILT IN ELECTRIC SENSOR AT HOTEL RESIDENCE OPERABLE WINDOWS.
SENSOR IS TO BE HARDWIRED TO JBOX FOR CONNECTION TO FANCOIL UNIT. REFER
TO MEP DRAWINGS FOR DETAILS AND SPECIFICATION.
8. BACK-UP WALL SHOWN FOR DESIGN INTENT AND COORDINATION ONLY. REFER TO
STRUCTURAL CONSULTANT'S DRAWINGS FOR DIMENSION, DETAILS, AND MATERIAL
FOR BACK-UP WALL.
GENERAL NOTES
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT OR PRESSURE PLATES AS INDICATED
ON ELEVATIONS WITH;
1) 150 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS. (SEE DETAILED
DRAWINGS FOR PROFILE)
2) 740mm DEEP SUNSHADE DEVICE MECHANICALLY ATTACHED TO MULLIONS.
REINFORCE MULLIONS AS REQD.
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT AT HORIZONTAL MULLIONS AND
CAPTURED MULLIONS AT VERTICAL MULLIONS WITH ;
1) 200 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
VERTICAL MULLION AS INDICATED ON ELEVATIONS.
2) 100 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS.
DIMENSIONED STONE MASONRY FOR EXTERIOR CLADDING. STONE PANELS
ARE INDEPENDENTLY SUPPORTED AND ANCHORED TO BACKUP WALL WITH
NON-CORROSIVE SUPPORTS. 8mm -12mm OPEN JOINTS BETWEEN STONE
PANELS. NON-STAINNG, NON-SHRINK SEALANT AT MASONRY OPENING
BETWEEN METAL FRAME AND STONE PANELS. SILL, JAMB, SOFFIT AND SPECIAL
PROFILED PANELS MAY BE REQUIRED FOR OPENINGS IN THE FIELD OF STONE.
SEAL BACKSIDE OF STONE WITH MANUFACTURED APPROVED NON-STAINING
SEALER. ALL EXPOSED SURFACES OF THE STONE TO THE VIEW TO BE
FINISHED. FACTORY FINISHED DRIP EDGE AT THE BOTTOM STONE PANEL AT
SOFFITS AND LINTELS. PROVIDE STAINLESS STEEL OR METAL FLASHING AT
EVERY OTHER CONTINUOUS HORIZONTAL JOINT.
VISION GLASS: IGU WITH LOW-e COAT (2nd surface)
Tower Glass Color & Coating: TO BE DECIDED
Podium Glass Color & Coating: TO BE DECIDED
SPANDREL GLASS INDICATION ON THE DRAWINGS.
Glass coating, Make up & Color: Same as G-1
Paint Color: TO BE DECIDED
PILKINGTON SYSTEM (or approved equal)GLASS PANELS FOR ICONIC
RETAIL AREA
Glass Make Up: Per manufacturer's design recommendation
G-6
G-2
SHADOW BOX INDICATION ON THE DRAWINGS
Vision Glass, coating, Make up & Color: Same as G-1
MTL-2
G-4
STOREFRONT GLASS PANELS:
WALL TYPE - 6 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED
G-7
WALL TYPE - 7 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO ELEVATIONS)
Glass Color, Coating & FRIT pattern: TO BE DECIDED
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS AND SHADOW BOXES ATTACHED
WITH STRUCTURAL SEALANT AT ALL 4 SIDES.
DESIGN BUILT STICK SYSTEM CURTAIN WALL INCLUDING EXTRUDED ALUM.
MULLIONS, METAL PANELS, LOW-e IGU PANELS ATTACHED WITH STRUCTURAL
SEALANT AND CAPTURED MULLIONS. CONNECT WITH W 02 AND W03 AS
REQUIRED. (ADDITIONAL MECHANICAL ATTACHMENT FOR METAL PANEL
SUGGESTED.)
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. HORIZONTAL MULLIONS ANCHORED
WITH SHEAR BLOCKS OR STEEL INSERTS. GLASS PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED METAL FACIA
PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER SLAB EDGE AND
PERIMETER BEAM.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. LOW-e IGUs PANELS AND IGUs WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRITT PATTERN AT 2nd & 3rd SURFACE
ATTACHED WITH STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED
METAL FACIA PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER
SLAB EDGE AND PERIMETER BEAM.
30mm THK. (nom.)TEMPERED GLASS PANEL (1.5m WIDE x 10m TALL) SET IN
STAINLESS STEEL CHANNELS ANCHORED AT TOP & BOTTOM SET ON HIGH
DENSITY SETTING BLOCKS, PRE-FORMED GASKET AT INTERIOR AND
PRE-FORMED GASKET WITH CLEAR SILICON SEALANT AT EXTERIOR.
Lateral brace: GLASS FINS SET IN STAINLESS STEEL CHANNEL
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO HANGER - 10m TALL - BY
FULLY ENCLOSED STEEL SUPPORT AND STEEL ANCHORS. IGU PANELS WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRIT PATTERN AT 2nd & 3rd SURFACE
WITH AND WITHOUT SHADOW BOXES ATTACHED WITH STRUCTURAL SEALANT
AT ALL 4 SIDES. INTERMEDIATE HORIZONTAL MULLIONS FOR GLAZING SUPPORT
ONLY. INDEPENDENTLY SUPPORTED NON IGU PANELS INSTALLED WITHIN THE
SYSTEM AS INDICATED ON ELEVATION.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS, LOW-e PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES.
G-8
WALL TYPES - 8 and 9 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED G-9
DESIGN BUILT ALUM. STOREFRONT WITH CUSTOM PROFILED MULLIONS
SUPPORTED SLAB TO SLAB/SUPPORT FRAMING BY FULLY ENCLOSED STEEL
SUPPORT AND STEEL ANCHORS, GLASS PANELS ATTACHED WITH STRUCTURAL
SEALANT AT HORIZONTAL MULLIONS AND CAPTURED AT VERTICAL MULLIONS,
GRANITE BASE AND LOUVERS AT TOP. ALUM FRAMED ENTRANCES WITH FLOOR
CLOSURES AS INDICATED ON ELEVATIONS.
DESIGN BUILT PILKINGTON PLANAR (or approved equal) GLAZING SYSTEM WITH
LOUVERS AND ENTRANCES. GLAZING CONNECTORS AND GLASS PANELS PER
MANUFACTURER'S DETAILS.
G-10 GLASS PANELS FOR BALCONY & TERRACE RAILING.
G-11
WALL TYPE - 11 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO Drawing A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
TYPICAL METAL FINISHES NOTE:
1. PAINT DIS-SIMILAR METALS TO AVOID GALVANIC ACTION.
2. SEAL ALL SCREW PENETRATIONS. ALL METAL ATTACHMENTS SHALL BE
CONCEALED IN PUBLIC TRAFFIC AREAS AND SPACES.
3. ALL ALUM SURFACES EXPOSE TO WEATHER SHALL BE 70% (3 coat) AND
INTERIOR SURFACES SHALL BE 50% (2 coat) KYNAR - or approved equal - FINISH.
4. WELD BRACING ANGLES OR SECONDARY FRAMING AT THE BACK OF METAL
PANEL TO AVOID OIL CANNING.
5. ALL METAL SURFACE EXPOSE TO VIEW SHALL BE FINISHED SAME INCLUDING
BUT NOT LIMITED TO REVEALS, RETURNS & EDGES
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE WITH 50mm (min.) INSULATION WITH;
1) FACTORY APPLIED VAPOR BARRIER AT INDICATED LOCATIONS.
2) FACTORY APPLIED VAPOR BARRIER AND METAL PANEL AT
INDICATED LOCATION.
CUSTOM PROFILE EXTRUSIONS OR BENT ALUM INCLUDING BUT NOT
LIMITED TO TRIMS, COPINGS, DRIP EDGES, RAILING POSTS.
THICKNESS & SIZES AS INDICATED ON DRAWINGS.
MTL-3 740 mm DEEP SUN SHADE AT TOWER.
3mm THK. (nom.) ALUM. METAL BENT TO FORM 1.0m x 5.1m (nom.)
PANEL WITH 50mm (min.) INSULATION & FACTORY APPLIED VAPOR
BARRIER.
MTL-4
MTL-6
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE FOR EXTERIOR CLADDING, SOFFITS, COLUMN
COVERS AND MISC.
L-2
ST-1
ST-2
ST-3
STORM CLASS ALUM LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING: 1.0m x 2.0m (nom.) TYPICAL STONE PANEL,
INDEPENDENTLY SUPPORTED, OPEN JOINTS
ALT 1: 100mm THK. (nom., min.) HONED FINISH FRENCH LIMESTONE
ALT2: 50 mm THK. (nom.) HONED FINISH FRENCH LIMESTONE PANELS
ON 100mm THK. (nom.) CONC. BACK UP PANELS
ALT3: 30mm - 50mm THK. (nom.) GRANITE PANELS
ALT4: 125mm THK. (nom.) PRECAST PANELS
L-4
ZEROSITELINE FLUSH ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-5
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-6
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING AT GROUND LEVEL: 0.35m x 2.5m (nom.) PANEL
Stone: TO BE DECIDED
30mm THK. (nom.) 1.5m LONG POLISHED GRANITE BASE AT WALL
TYPES - SF01,SF02 & SF03.
150mm (min.) - 350mm (max.) HEIGHT OF BASE ABOVE FINISHED
FLOORING.
Stone color: TO BE DECIDED
G-7a NON IGU GLASS PANELS AT Jr. BALLROOM PRE-FUNCTION AREA
G-7b
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO DRAWING A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
REFER TO EXTERIOR WALL CONSULTANT'S SPECIFICATION FOR
GLASS MAKE UP, DETAILS AND PERFORMANCE INFORMATION.
G-11a
NON IGU GLASS PANELS AT MAIN BALLROOM PRE-FUNCTION
AREA
COMPOSITE SYSTEM OF STICK BUILT CURTAIN WALL AND ALUM. FRAMED
PUNCHED WINDOWS WITH CUSTOM PROFILED EXTERIOR TRIMS INSTALLED
WITHIN FIELD FOR STONE AND METAL PANELS.
ST-4
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT WALL TYPE - W08
Stone type & finish: TO BE DECIDED
ST-5
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT LOCATIONS INDICATED ON ELEVATIONS.
Stone type & finish: TO BE DECIDED
SC-1
50mm - 75mmTHK. (nom.) STUCCO, THICKNESS TO DEPEND ON
LOCATION AND FINISH.
Finish & Color: TO BE DECIDED
2 01/24/2011 2
03
03
07/01/2011 4
H.1
01
1:20
TYPICAL PARTIAL PLAN @ LEVEL 9-40, 41-60
02
1:20
TYPICAL PARTIAL ELEVATION @ LEVEL
03
1:20
TYPICAL PARTIAL SECTION
500 900 500 500 900 500
G-1
G-1 G-1
G-1
G-1
G-1
G-1 G-1 G-1
A423
1
G-1
G-1 G-1
G-1
G-1 G-1
G-2 G-2
G-2 G-2
TYPICAL
PARTIAL
SECTION
@
OPERABLE
UNIT
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2 G-2
G-2
G-2 G-2 G-2 G-2 G-2 G-2 G-2
G-2
G-2 G-2 G-2
G-2 G-2 G-2 G-2 G-2
G-2 G-2
G-2 G-2 G-2
G-2 G-2 G-2
04
1:20
2600
MODULE A
1900
MODULE B
2600
MODULE A
1900
MODULE B
G-2 G-2 G-2
G-2 G-2 G-2
G-2 G-2 G-2
5
3
0
A443
03
N
KEY PLAN
P
lo
t D
a
te
: 3
0
J
u
n
e
2
0
1
1
H
a
n
d
e
l A
s
s
o
c
ia
te
s
L
td

SHANGR/-LA AT
THE FORT, MAN/LA
FORT BONIFACIO
ARCHITECTS CO.
GF & PARTNERS
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8946281 to 85 FAX 63-2-8921861 E-MAIL: postmaster@gfparchitects.com
XAVIER ANTONIO J . GARCIA TEODORO H. NARCISO
TEOFILO A. SANTIAGO J R. ANNETTE F. GADDI-LIGANOR
CONSULTING ENGINEERS
DCCD ENGINEERING
112 SOL BUILDING, AMORSOLO STREET, LEGASPI VILLAGE, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8924586 TO 97 FAX 63-2-8182142 E-MAIL info@dccd.com
CORPORATION
IM MARTINEZ
UNIT 410 FEDMAN SUITES CONDOMINIUMBLDG. NO. 199-201 SALCEDO ST. LEGASPI VILLAGE
TELEPHONE 632-8932898 FAX 632-8925188 E-MAIL immce@pldtdsl.net
MAKATI CITY 1229 PHILIPPINES
SHANGRI-LA HOTEL, INC.
CONSULTING ENGINEERS
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL: pmt.slfm@shangri-la.com
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL:
20th FLOOR EASTERN CENTRAL PLAZA 3 YIU HING ROAD SHAUKEIWAN HONG KONG
RIDER LEVETT BUCKNALL
LTD.
HANDEL ASSOCIATES
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
CONSULTING ENGINEERS LTD
DESIMONE
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
J.P.R SDN. BHD.
12TH FLOOR, PENAS TOWER, 488A, J ALAN BURMA 10350, PENANG, MALAYSIA
A R C H I T E C T
:
:
:
:
ANNETTE F. GADDI-LIGANOR
SUPERSTRUCTURE ADVANCE TENDER SET
A423
TOWER WALL TYPES -
TYPE 3
EXTERIOR WALL TYPES
EXTERIOR MATERIALS
G-1
G-3
L-1
MTL-1
G-5
1. PROVIDE OPERABLE VENTS/WINDOWS FOR NATURAL VENTILATION AS MANDATED BY
APPLICABLE BUILDING CODES. THE LOCATION FOR OPERABLE VENTS/WINDOWS &
SIZES MAY CHANGE PER DESIGN DEVELOPMENT OF FACADE.
2. REFER TO DRAWING G001 FOR GENERAL EXTERIOR ENVELOPE NOTES.
3. REFER TO SERIES A1.00 FOR BUILDING PLANS.
4. REFER TO SERIES A4.00 FOR EXTERIOR WALL SECTIONS, TYPES AND DETAILS.
5. REFER TO SERIES A8.00 FOR GLASS PANELS SIZES.
6. LIGHTENING GROUNDING TO BE WIRED TO CURTAIN WALL. WIRING TO BE TAKEN TO
NEAREST COLUMN & CONDUIT TO RUN DOWN TO BUILDING FOUNDATION.
7. PROVIDE BUILT IN ELECTRIC SENSOR AT HOTEL RESIDENCE OPERABLE WINDOWS.
SENSOR IS TO BE HARDWIRED TO JBOX FOR CONNECTION TO FANCOIL UNIT. REFER
TO MEP DRAWINGS FOR DETAILS AND SPECIFICATION.
8. BACK-UP WALL SHOWN FOR DESIGN INTENT AND COORDINATION ONLY. REFER TO
STRUCTURAL CONSULTANT'S DRAWINGS FOR DIMENSION, DETAILS, AND MATERIAL
FOR BACK-UP WALL.
GENERAL NOTES
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT OR PRESSURE PLATES AS INDICATED
ON ELEVATIONS WITH;
1) 150 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS. (SEE DETAILED
DRAWINGS FOR PROFILE)
2) 740mm DEEP SUNSHADE DEVICE MECHANICALLY ATTACHED TO MULLIONS.
REINFORCE MULLIONS AS REQD.
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT AT HORIZONTAL MULLIONS AND
CAPTURED MULLIONS AT VERTICAL MULLIONS WITH ;
1) 200 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
VERTICAL MULLION AS INDICATED ON ELEVATIONS.
2) 100 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS.
DIMENSIONED STONE MASONRY FOR EXTERIOR CLADDING. STONE PANELS
ARE INDEPENDENTLY SUPPORTED AND ANCHORED TO BACKUP WALL WITH
NON-CORROSIVE SUPPORTS. 8mm -12mm OPEN JOINTS BETWEEN STONE
PANELS. NON-STAINNG, NON-SHRINK SEALANT AT MASONRY OPENING
BETWEEN METAL FRAME AND STONE PANELS. SILL, JAMB, SOFFIT AND SPECIAL
PROFILED PANELS MAY BE REQUIRED FOR OPENINGS IN THE FIELD OF STONE.
SEAL BACKSIDE OF STONE WITH MANUFACTURED APPROVED NON-STAINING
SEALER. ALL EXPOSED SURFACES OF THE STONE TO THE VIEW TO BE
FINISHED. FACTORY FINISHED DRIP EDGE AT THE BOTTOM STONE PANEL AT
SOFFITS AND LINTELS. PROVIDE STAINLESS STEEL OR METAL FLASHING AT
EVERY OTHER CONTINUOUS HORIZONTAL JOINT.
VISION GLASS: IGU WITH LOW-e COAT (2nd surface)
Tower Glass Color & Coating: TO BE DECIDED
Podium Glass Color & Coating: TO BE DECIDED
SPANDREL GLASS INDICATION ON THE DRAWINGS.
Glass coating, Make up & Color: Same as G-1
Paint Color: TO BE DECIDED
PILKINGTON SYSTEM (or approved equal)GLASS PANELS FOR ICONIC
RETAIL AREA
Glass Make Up: Per manufacturer's design recommendation
G-6
G-2
SHADOW BOX INDICATION ON THE DRAWINGS
Vision Glass, coating, Make up & Color: Same as G-1
MTL-2
G-4
STOREFRONT GLASS PANELS:
WALL TYPE - 6 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED
G-7
WALL TYPE - 7 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO ELEVATIONS)
Glass Color, Coating & FRIT pattern: TO BE DECIDED
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS AND SHADOW BOXES ATTACHED
WITH STRUCTURAL SEALANT AT ALL 4 SIDES.
DESIGN BUILT STICK SYSTEM CURTAIN WALL INCLUDING EXTRUDED ALUM.
MULLIONS, METAL PANELS, LOW-e IGU PANELS ATTACHED WITH STRUCTURAL
SEALANT AND CAPTURED MULLIONS. CONNECT WITH W 02 AND W03 AS
REQUIRED. (ADDITIONAL MECHANICAL ATTACHMENT FOR METAL PANEL
SUGGESTED.)
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. HORIZONTAL MULLIONS ANCHORED
WITH SHEAR BLOCKS OR STEEL INSERTS. GLASS PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED METAL FACIA
PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER SLAB EDGE AND
PERIMETER BEAM.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. LOW-e IGUs PANELS AND IGUs WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRITT PATTERN AT 2nd & 3rd SURFACE
ATTACHED WITH STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED
METAL FACIA PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER
SLAB EDGE AND PERIMETER BEAM.
30mm THK. (nom.)TEMPERED GLASS PANEL (1.5m WIDE x 10m TALL) SET IN
STAINLESS STEEL CHANNELS ANCHORED AT TOP & BOTTOM SET ON HIGH
DENSITY SETTING BLOCKS, PRE-FORMED GASKET AT INTERIOR AND
PRE-FORMED GASKET WITH CLEAR SILICON SEALANT AT EXTERIOR.
Lateral brace: GLASS FINS SET IN STAINLESS STEEL CHANNEL
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO HANGER - 10m TALL - BY
FULLY ENCLOSED STEEL SUPPORT AND STEEL ANCHORS. IGU PANELS WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRIT PATTERN AT 2nd & 3rd SURFACE
WITH AND WITHOUT SHADOW BOXES ATTACHED WITH STRUCTURAL SEALANT
AT ALL 4 SIDES. INTERMEDIATE HORIZONTAL MULLIONS FOR GLAZING SUPPORT
ONLY. INDEPENDENTLY SUPPORTED NON IGU PANELS INSTALLED WITHIN THE
SYSTEM AS INDICATED ON ELEVATION.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS, LOW-e PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES.
G-8
WALL TYPES - 8 and 9 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED G-9
DESIGN BUILT ALUM. STOREFRONT WITH CUSTOM PROFILED MULLIONS
SUPPORTED SLAB TO SLAB/SUPPORT FRAMING BY FULLY ENCLOSED STEEL
SUPPORT AND STEEL ANCHORS, GLASS PANELS ATTACHED WITH STRUCTURAL
SEALANT AT HORIZONTAL MULLIONS AND CAPTURED AT VERTICAL MULLIONS,
GRANITE BASE AND LOUVERS AT TOP. ALUM FRAMED ENTRANCES WITH FLOOR
CLOSURES AS INDICATED ON ELEVATIONS.
DESIGN BUILT PILKINGTON PLANAR (or approved equal) GLAZING SYSTEM WITH
LOUVERS AND ENTRANCES. GLAZING CONNECTORS AND GLASS PANELS PER
MANUFACTURER'S DETAILS.
G-10 GLASS PANELS FOR BALCONY & TERRACE RAILING.
G-11
WALL TYPE - 11 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO Drawing A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
TYPICAL METAL FINISHES NOTE:
1. PAINT DIS-SIMILAR METALS TO AVOID GALVANIC ACTION.
2. SEAL ALL SCREW PENETRATIONS. ALL METAL ATTACHMENTS SHALL BE
CONCEALED IN PUBLIC TRAFFIC AREAS AND SPACES.
3. ALL ALUM SURFACES EXPOSE TO WEATHER SHALL BE 70% (3 coat) AND
INTERIOR SURFACES SHALL BE 50% (2 coat) KYNAR - or approved equal - FINISH.
4. WELD BRACING ANGLES OR SECONDARY FRAMING AT THE BACK OF METAL
PANEL TO AVOID OIL CANNING.
5. ALL METAL SURFACE EXPOSE TO VIEW SHALL BE FINISHED SAME INCLUDING
BUT NOT LIMITED TO REVEALS, RETURNS & EDGES
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE WITH 50mm (min.) INSULATION WITH;
1) FACTORY APPLIED VAPOR BARRIER AT INDICATED LOCATIONS.
2) FACTORY APPLIED VAPOR BARRIER AND METAL PANEL AT
INDICATED LOCATION.
CUSTOM PROFILE EXTRUSIONS OR BENT ALUM INCLUDING BUT NOT
LIMITED TO TRIMS, COPINGS, DRIP EDGES, RAILING POSTS.
THICKNESS & SIZES AS INDICATED ON DRAWINGS.
MTL-3 740 mm DEEP SUN SHADE AT TOWER.
3mm THK. (nom.) ALUM. METAL BENT TO FORM 1.0m x 5.1m (nom.)
PANEL WITH 50mm (min.) INSULATION & FACTORY APPLIED VAPOR
BARRIER.
MTL-4
MTL-6
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE FOR EXTERIOR CLADDING, SOFFITS, COLUMN
COVERS AND MISC.
L-2
ST-1
ST-2
ST-3
STORM CLASS ALUM LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING: 1.0m x 2.0m (nom.) TYPICAL STONE PANEL,
INDEPENDENTLY SUPPORTED, OPEN JOINTS
ALT 1: 100mm THK. (nom., min.) HONED FINISH FRENCH LIMESTONE
ALT2: 50 mm THK. (nom.) HONED FINISH FRENCH LIMESTONE PANELS
ON 100mm THK. (nom.) CONC. BACK UP PANELS
ALT3: 30mm - 50mm THK. (nom.) GRANITE PANELS
ALT4: 125mm THK. (nom.) PRECAST PANELS
L-4
ZEROSITELINE FLUSH ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-5
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-6
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING AT GROUND LEVEL: 0.35m x 2.5m (nom.) PANEL
Stone: TO BE DECIDED
30mm THK. (nom.) 1.5m LONG POLISHED GRANITE BASE AT WALL
TYPES - SF01,SF02 & SF03.
150mm (min.) - 350mm (max.) HEIGHT OF BASE ABOVE FINISHED
FLOORING.
Stone color: TO BE DECIDED
G-7a NON IGU GLASS PANELS AT Jr. BALLROOM PRE-FUNCTION AREA
G-7b
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO DRAWING A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
REFER TO EXTERIOR WALL CONSULTANT'S SPECIFICATION FOR
GLASS MAKE UP, DETAILS AND PERFORMANCE INFORMATION.
G-11a
NON IGU GLASS PANELS AT MAIN BALLROOM PRE-FUNCTION
AREA
COMPOSITE SYSTEM OF STICK BUILT CURTAIN WALL AND ALUM. FRAMED
PUNCHED WINDOWS WITH CUSTOM PROFILED EXTERIOR TRIMS INSTALLED
WITHIN FIELD FOR STONE AND METAL PANELS.
ST-4
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT WALL TYPE - W08
Stone type & finish: TO BE DECIDED
ST-5
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT LOCATIONS INDICATED ON ELEVATIONS.
Stone type & finish: TO BE DECIDED
SC-1
50mm - 75mmTHK. (nom.) STUCCO, THICKNESS TO DEPEND ON
LOCATION AND FINISH.
Finish & Color: TO BE DECIDED
2 01/24/2011 2
02
02
07/01/2011 4
T.O.S. +175.1m
LEVEL 41
T.O.S. +171.6m
LEVEL 40M
3
3
01
1:20
PARTIAL PLAN @ LEVEL 40M
02
1:20
PARTIAL PLAN @ LEVEL 9-40,41-59
03
1:20
PARTIAL ELEVATION @ LEVEL 40M-42
05
1:20
PARTIAL SECTION @ LEVEL 40M-42
04
1:20
PARTIAL SECTION @ LEVEL 40M-42
2
1
1
5
0
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
G-2
W-03 W-03
REFER TO
INTERIOR
DESIGNER'S
DRAWINGS
FOR FINISHED
CEILING
REFER TO
INTERIOR
DESIGNER'S
DRAWINGS
FOR FINISHED
CEILING
1215
N
KEY PLAN
P
lo
t D
a
te
: 3
0
J
u
n
e
2
0
1
1
H
a
n
d
e
l A
s
s
o
c
ia
te
s
L
td

SHANGR/-LA AT
THE FORT, MAN/LA
FORT BONIFACIO
ARCHITECTS CO.
GF & PARTNERS
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8946281 to 85 FAX 63-2-8921861 E-MAIL: postmaster@gfparchitects.com
XAVIER ANTONIO J . GARCIA TEODORO H. NARCISO
TEOFILO A. SANTIAGO J R. ANNETTE F. GADDI-LIGANOR
CONSULTING ENGINEERS
DCCD ENGINEERING
112 SOL BUILDING, AMORSOLO STREET, LEGASPI VILLAGE, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8924586 TO 97 FAX 63-2-8182142 E-MAIL info@dccd.com
CORPORATION
IM MARTINEZ
UNIT 410 FEDMAN SUITES CONDOMINIUMBLDG. NO. 199-201 SALCEDO ST. LEGASPI VILLAGE
TELEPHONE 632-8932898 FAX 632-8925188 E-MAIL immce@pldtdsl.net
MAKATI CITY 1229 PHILIPPINES
SHANGRI-LA HOTEL, INC.
CONSULTING ENGINEERS
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL: pmt.slfm@shangri-la.com
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL:
20th FLOOR EASTERN CENTRAL PLAZA 3 YIU HING ROAD SHAUKEIWAN HONG KONG
RIDER LEVETT BUCKNALL
LTD.
HANDEL ASSOCIATES
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
CONSULTING ENGINEERS LTD
DESIMONE
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
J.P.R SDN. BHD.
12TH FLOOR, PENAS TOWER, 488A, J ALAN BURMA 10350, PENANG, MALAYSIA
A R C H I T E C T
:
:
:
:
ANNETTE F. GADDI-LIGANOR
SUPERSTRUCTURE ADVANCE TENDER SET
A423A
TOWER WALL TYPES -
TYPE 3
EXTERIOR WALL TYPES
EXTERIOR MATERIALS
G-1
G-3
L-1
MTL-1
G-5
1. PROVIDE OPERABLE VENTS/WINDOWS FOR NATURAL VENTILATION AS MANDATED BY
APPLICABLE BUILDING CODES. THE LOCATION FOR OPERABLE VENTS/WINDOWS &
SIZES MAY CHANGE PER DESIGN DEVELOPMENT OF FACADE.
2. REFER TO DRAWING G001 FOR GENERAL EXTERIOR ENVELOPE NOTES.
3. REFER TO SERIES A1.00 FOR BUILDING PLANS.
4. REFER TO SERIES A4.00 FOR EXTERIOR WALL SECTIONS, TYPES AND DETAILS.
5. REFER TO SERIES A8.00 FOR GLASS PANELS SIZES.
6. LIGHTENING GROUNDING TO BE WIRED TO CURTAIN WALL. WIRING TO BE TAKEN TO
NEAREST COLUMN & CONDUIT TO RUN DOWN TO BUILDING FOUNDATION.
7. PROVIDE BUILT IN ELECTRIC SENSOR AT HOTEL RESIDENCE OPERABLE WINDOWS.
SENSOR IS TO BE HARDWIRED TO JBOX FOR CONNECTION TO FANCOIL UNIT. REFER
TO MEP DRAWINGS FOR DETAILS AND SPECIFICATION.
8. BACK-UP WALL SHOWN FOR DESIGN INTENT AND COORDINATION ONLY. REFER TO
STRUCTURAL CONSULTANT'S DRAWINGS FOR DIMENSION, DETAILS, AND MATERIAL
FOR BACK-UP WALL.
GENERAL NOTES
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT OR PRESSURE PLATES AS INDICATED
ON ELEVATIONS WITH;
1) 150 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS. (SEE DETAILED
DRAWINGS FOR PROFILE)
2) 740mm DEEP SUNSHADE DEVICE MECHANICALLY ATTACHED TO MULLIONS.
REINFORCE MULLIONS AS REQD.
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT AT HORIZONTAL MULLIONS AND
CAPTURED MULLIONS AT VERTICAL MULLIONS WITH ;
1) 200 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
VERTICAL MULLION AS INDICATED ON ELEVATIONS.
2) 100 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS.
DIMENSIONED STONE MASONRY FOR EXTERIOR CLADDING. STONE PANELS
ARE INDEPENDENTLY SUPPORTED AND ANCHORED TO BACKUP WALL WITH
NON-CORROSIVE SUPPORTS. 8mm -12mm OPEN JOINTS BETWEEN STONE
PANELS. NON-STAINNG, NON-SHRINK SEALANT AT MASONRY OPENING
BETWEEN METAL FRAME AND STONE PANELS. SILL, JAMB, SOFFIT AND SPECIAL
PROFILED PANELS MAY BE REQUIRED FOR OPENINGS IN THE FIELD OF STONE.
SEAL BACKSIDE OF STONE WITH MANUFACTURED APPROVED NON-STAINING
SEALER. ALL EXPOSED SURFACES OF THE STONE TO THE VIEW TO BE
FINISHED. FACTORY FINISHED DRIP EDGE AT THE BOTTOM STONE PANEL AT
SOFFITS AND LINTELS. PROVIDE STAINLESS STEEL OR METAL FLASHING AT
EVERY OTHER CONTINUOUS HORIZONTAL JOINT.
VISION GLASS: IGU WITH LOW-e COAT (2nd surface)
Tower Glass Color & Coating: TO BE DECIDED
Podium Glass Color & Coating: TO BE DECIDED
SPANDREL GLASS INDICATION ON THE DRAWINGS.
Glass coating, Make up & Color: Same as G-1
Paint Color: TO BE DECIDED
PILKINGTON SYSTEM (or approved equal)GLASS PANELS FOR ICONIC
RETAIL AREA
Glass Make Up: Per manufacturer's design recommendation
G-6
G-2
SHADOW BOX INDICATION ON THE DRAWINGS
Vision Glass, coating, Make up & Color: Same as G-1
MTL-2
G-4
STOREFRONT GLASS PANELS:
WALL TYPE - 6 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED
G-7
WALL TYPE - 7 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO ELEVATIONS)
Glass Color, Coating & FRIT pattern: TO BE DECIDED
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS AND SHADOW BOXES ATTACHED
WITH STRUCTURAL SEALANT AT ALL 4 SIDES.
DESIGN BUILT STICK SYSTEM CURTAIN WALL INCLUDING EXTRUDED ALUM.
MULLIONS, METAL PANELS, LOW-e IGU PANELS ATTACHED WITH STRUCTURAL
SEALANT AND CAPTURED MULLIONS. CONNECT WITH W 02 AND W03 AS
REQUIRED. (ADDITIONAL MECHANICAL ATTACHMENT FOR METAL PANEL
SUGGESTED.)
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. HORIZONTAL MULLIONS ANCHORED
WITH SHEAR BLOCKS OR STEEL INSERTS. GLASS PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED METAL FACIA
PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER SLAB EDGE AND
PERIMETER BEAM.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. LOW-e IGUs PANELS AND IGUs WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRITT PATTERN AT 2nd & 3rd SURFACE
ATTACHED WITH STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED
METAL FACIA PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER
SLAB EDGE AND PERIMETER BEAM.
30mm THK. (nom.)TEMPERED GLASS PANEL (1.5m WIDE x 10m TALL) SET IN
STAINLESS STEEL CHANNELS ANCHORED AT TOP & BOTTOM SET ON HIGH
DENSITY SETTING BLOCKS, PRE-FORMED GASKET AT INTERIOR AND
PRE-FORMED GASKET WITH CLEAR SILICON SEALANT AT EXTERIOR.
Lateral brace: GLASS FINS SET IN STAINLESS STEEL CHANNEL
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO HANGER - 10m TALL - BY
FULLY ENCLOSED STEEL SUPPORT AND STEEL ANCHORS. IGU PANELS WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRIT PATTERN AT 2nd & 3rd SURFACE
WITH AND WITHOUT SHADOW BOXES ATTACHED WITH STRUCTURAL SEALANT
AT ALL 4 SIDES. INTERMEDIATE HORIZONTAL MULLIONS FOR GLAZING SUPPORT
ONLY. INDEPENDENTLY SUPPORTED NON IGU PANELS INSTALLED WITHIN THE
SYSTEM AS INDICATED ON ELEVATION.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS, LOW-e PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES.
G-8
WALL TYPES - 8 and 9 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED G-9
DESIGN BUILT ALUM. STOREFRONT WITH CUSTOM PROFILED MULLIONS
SUPPORTED SLAB TO SLAB/SUPPORT FRAMING BY FULLY ENCLOSED STEEL
SUPPORT AND STEEL ANCHORS, GLASS PANELS ATTACHED WITH STRUCTURAL
SEALANT AT HORIZONTAL MULLIONS AND CAPTURED AT VERTICAL MULLIONS,
GRANITE BASE AND LOUVERS AT TOP. ALUM FRAMED ENTRANCES WITH FLOOR
CLOSURES AS INDICATED ON ELEVATIONS.
DESIGN BUILT PILKINGTON PLANAR (or approved equal) GLAZING SYSTEM WITH
LOUVERS AND ENTRANCES. GLAZING CONNECTORS AND GLASS PANELS PER
MANUFACTURER'S DETAILS.
G-10 GLASS PANELS FOR BALCONY & TERRACE RAILING.
G-11
WALL TYPE - 11 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO Drawing A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
TYPICAL METAL FINISHES NOTE:
1. PAINT DIS-SIMILAR METALS TO AVOID GALVANIC ACTION.
2. SEAL ALL SCREW PENETRATIONS. ALL METAL ATTACHMENTS SHALL BE
CONCEALED IN PUBLIC TRAFFIC AREAS AND SPACES.
3. ALL ALUM SURFACES EXPOSE TO WEATHER SHALL BE 70% (3 coat) AND
INTERIOR SURFACES SHALL BE 50% (2 coat) KYNAR - or approved equal - FINISH.
4. WELD BRACING ANGLES OR SECONDARY FRAMING AT THE BACK OF METAL
PANEL TO AVOID OIL CANNING.
5. ALL METAL SURFACE EXPOSE TO VIEW SHALL BE FINISHED SAME INCLUDING
BUT NOT LIMITED TO REVEALS, RETURNS & EDGES
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE WITH 50mm (min.) INSULATION WITH;
1) FACTORY APPLIED VAPOR BARRIER AT INDICATED LOCATIONS.
2) FACTORY APPLIED VAPOR BARRIER AND METAL PANEL AT
INDICATED LOCATION.
CUSTOM PROFILE EXTRUSIONS OR BENT ALUM INCLUDING BUT NOT
LIMITED TO TRIMS, COPINGS, DRIP EDGES, RAILING POSTS.
THICKNESS & SIZES AS INDICATED ON DRAWINGS.
MTL-3 740 mm DEEP SUN SHADE AT TOWER.
3mm THK. (nom.) ALUM. METAL BENT TO FORM 1.0m x 5.1m (nom.)
PANEL WITH 50mm (min.) INSULATION & FACTORY APPLIED VAPOR
BARRIER.
MTL-4
MTL-6
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE FOR EXTERIOR CLADDING, SOFFITS, COLUMN
COVERS AND MISC.
L-2
ST-1
ST-2
ST-3
STORM CLASS ALUM LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING: 1.0m x 2.0m (nom.) TYPICAL STONE PANEL,
INDEPENDENTLY SUPPORTED, OPEN JOINTS
ALT 1: 100mm THK. (nom., min.) HONED FINISH FRENCH LIMESTONE
ALT2: 50 mm THK. (nom.) HONED FINISH FRENCH LIMESTONE PANELS
ON 100mm THK. (nom.) CONC. BACK UP PANELS
ALT3: 30mm - 50mm THK. (nom.) GRANITE PANELS
ALT4: 125mm THK. (nom.) PRECAST PANELS
L-4
ZEROSITELINE FLUSH ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-5
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-6
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING AT GROUND LEVEL: 0.35m x 2.5m (nom.) PANEL
Stone: TO BE DECIDED
30mm THK. (nom.) 1.5m LONG POLISHED GRANITE BASE AT WALL
TYPES - SF01,SF02 & SF03.
150mm (min.) - 350mm (max.) HEIGHT OF BASE ABOVE FINISHED
FLOORING.
Stone color: TO BE DECIDED
G-7a NON IGU GLASS PANELS AT Jr. BALLROOM PRE-FUNCTION AREA
G-7b
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO DRAWING A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
REFER TO EXTERIOR WALL CONSULTANT'S SPECIFICATION FOR
GLASS MAKE UP, DETAILS AND PERFORMANCE INFORMATION.
G-11a
NON IGU GLASS PANELS AT MAIN BALLROOM PRE-FUNCTION
AREA
COMPOSITE SYSTEM OF STICK BUILT CURTAIN WALL AND ALUM. FRAMED
PUNCHED WINDOWS WITH CUSTOM PROFILED EXTERIOR TRIMS INSTALLED
WITHIN FIELD FOR STONE AND METAL PANELS.
ST-4
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT WALL TYPE - W08
Stone type & finish: TO BE DECIDED
ST-5
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT LOCATIONS INDICATED ON ELEVATIONS.
Stone type & finish: TO BE DECIDED
SC-1
50mm - 75mmTHK. (nom.) STUCCO, THICKNESS TO DEPEND ON
LOCATION AND FINISH.
Finish & Color: TO BE DECIDED
2 01/24/2011 2
03
03
07/01/2011 4
03
1:20
TYPICAL PARTIAL ELEVATION @ LEVEL 40M-42
04
1:20
TYPICAL PARTIAL SECTION @ LEVEL 40M-42
H.1
2
0
0
02
1:20
TYPICAL PARTIAL ELEVATION @ LEVEL 40M-42
1
2
0
8
7
7
T.O.S. +171.55m
LEVEL 40M
MTL-1
A424
3
SLOPE
N
KEY PLAN
P
lo
t D
a
te
: 3
0
J
u
n
e
2
0
1
1
H
a
n
d
e
l A
s
s
o
c
ia
te
s
L
td

SHANGR/-LA AT
THE FORT, MAN/LA
FORT BONIFACIO
ARCHITECTS CO.
GF & PARTNERS
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8946281 to 85 FAX 63-2-8921861 E-MAIL: postmaster@gfparchitects.com
XAVIER ANTONIO J . GARCIA TEODORO H. NARCISO
TEOFILO A. SANTIAGO J R. ANNETTE F. GADDI-LIGANOR
CONSULTING ENGINEERS
DCCD ENGINEERING
112 SOL BUILDING, AMORSOLO STREET, LEGASPI VILLAGE, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8924586 TO 97 FAX 63-2-8182142 E-MAIL info@dccd.com
CORPORATION
IM MARTINEZ
UNIT 410 FEDMAN SUITES CONDOMINIUMBLDG. NO. 199-201 SALCEDO ST. LEGASPI VILLAGE
TELEPHONE 632-8932898 FAX 632-8925188 E-MAIL immce@pldtdsl.net
MAKATI CITY 1229 PHILIPPINES
SHANGRI-LA HOTEL, INC.
CONSULTING ENGINEERS
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL: pmt.slfm@shangri-la.com
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL:
20th FLOOR EASTERN CENTRAL PLAZA 3 YIU HING ROAD SHAUKEIWAN HONG KONG
RIDER LEVETT BUCKNALL
LTD.
HANDEL ASSOCIATES
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
CONSULTING ENGINEERS LTD
DESIMONE
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
J.P.R SDN. BHD.
12TH FLOOR, PENAS TOWER, 488A, J ALAN BURMA 10350, PENANG, MALAYSIA
A R C H I T E C T
:
:
:
:
ANNETTE F. GADDI-LIGANOR
SUPERSTRUCTURE ADVANCE TENDER SET
A424
TOWER WALL TYPES -
TYPE 4
EXTERIOR WALL TYPES
EXTERIOR MATERIALS
G-1
G-3
L-1
MTL-1
G-5
1. PROVIDE OPERABLE VENTS/WINDOWS FOR NATURAL VENTILATION AS MANDATED BY
APPLICABLE BUILDING CODES. THE LOCATION FOR OPERABLE VENTS/WINDOWS &
SIZES MAY CHANGE PER DESIGN DEVELOPMENT OF FACADE.
2. REFER TO DRAWING G001 FOR GENERAL EXTERIOR ENVELOPE NOTES.
3. REFER TO SERIES A1.00 FOR BUILDING PLANS.
4. REFER TO SERIES A4.00 FOR EXTERIOR WALL SECTIONS, TYPES AND DETAILS.
5. REFER TO SERIES A8.00 FOR GLASS PANELS SIZES.
6. LIGHTENING GROUNDING TO BE WIRED TO CURTAIN WALL. WIRING TO BE TAKEN TO
NEAREST COLUMN & CONDUIT TO RUN DOWN TO BUILDING FOUNDATION.
7. PROVIDE BUILT IN ELECTRIC SENSOR AT HOTEL RESIDENCE OPERABLE WINDOWS.
SENSOR IS TO BE HARDWIRED TO JBOX FOR CONNECTION TO FANCOIL UNIT. REFER
TO MEP DRAWINGS FOR DETAILS AND SPECIFICATION.
8. BACK-UP WALL SHOWN FOR DESIGN INTENT AND COORDINATION ONLY. REFER TO
STRUCTURAL CONSULTANT'S DRAWINGS FOR DIMENSION, DETAILS, AND MATERIAL
FOR BACK-UP WALL.
GENERAL NOTES
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT OR PRESSURE PLATES AS INDICATED
ON ELEVATIONS WITH;
1) 150 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS. (SEE DETAILED
DRAWINGS FOR PROFILE)
2) 740mm DEEP SUNSHADE DEVICE MECHANICALLY ATTACHED TO MULLIONS.
REINFORCE MULLIONS AS REQD.
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT AT HORIZONTAL MULLIONS AND
CAPTURED MULLIONS AT VERTICAL MULLIONS WITH ;
1) 200 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
VERTICAL MULLION AS INDICATED ON ELEVATIONS.
2) 100 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS.
DIMENSIONED STONE MASONRY FOR EXTERIOR CLADDING. STONE PANELS
ARE INDEPENDENTLY SUPPORTED AND ANCHORED TO BACKUP WALL WITH
NON-CORROSIVE SUPPORTS. 8mm -12mm OPEN JOINTS BETWEEN STONE
PANELS. NON-STAINNG, NON-SHRINK SEALANT AT MASONRY OPENING
BETWEEN METAL FRAME AND STONE PANELS. SILL, JAMB, SOFFIT AND SPECIAL
PROFILED PANELS MAY BE REQUIRED FOR OPENINGS IN THE FIELD OF STONE.
SEAL BACKSIDE OF STONE WITH MANUFACTURED APPROVED NON-STAINING
SEALER. ALL EXPOSED SURFACES OF THE STONE TO THE VIEW TO BE
FINISHED. FACTORY FINISHED DRIP EDGE AT THE BOTTOM STONE PANEL AT
SOFFITS AND LINTELS. PROVIDE STAINLESS STEEL OR METAL FLASHING AT
EVERY OTHER CONTINUOUS HORIZONTAL JOINT.
VISION GLASS: IGU WITH LOW-e COAT (2nd surface)
Tower Glass Color & Coating: TO BE DECIDED
Podium Glass Color & Coating: TO BE DECIDED
SPANDREL GLASS INDICATION ON THE DRAWINGS.
Glass coating, Make up & Color: Same as G-1
Paint Color: TO BE DECIDED
PILKINGTON SYSTEM (or approved equal)GLASS PANELS FOR ICONIC
RETAIL AREA
Glass Make Up: Per manufacturer's design recommendation
G-6
G-2
SHADOW BOX INDICATION ON THE DRAWINGS
Vision Glass, coating, Make up & Color: Same as G-1
MTL-2
G-4
STOREFRONT GLASS PANELS:
WALL TYPE - 6 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED
G-7
WALL TYPE - 7 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO ELEVATIONS)
Glass Color, Coating & FRIT pattern: TO BE DECIDED
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS AND SHADOW BOXES ATTACHED
WITH STRUCTURAL SEALANT AT ALL 4 SIDES.
DESIGN BUILT STICK SYSTEM CURTAIN WALL INCLUDING EXTRUDED ALUM.
MULLIONS, METAL PANELS, LOW-e IGU PANELS ATTACHED WITH STRUCTURAL
SEALANT AND CAPTURED MULLIONS. CONNECT WITH W 02 AND W03 AS
REQUIRED. (ADDITIONAL MECHANICAL ATTACHMENT FOR METAL PANEL
SUGGESTED.)
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. HORIZONTAL MULLIONS ANCHORED
WITH SHEAR BLOCKS OR STEEL INSERTS. GLASS PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED METAL FACIA
PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER SLAB EDGE AND
PERIMETER BEAM.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. LOW-e IGUs PANELS AND IGUs WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRITT PATTERN AT 2nd & 3rd SURFACE
ATTACHED WITH STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED
METAL FACIA PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER
SLAB EDGE AND PERIMETER BEAM.
30mm THK. (nom.)TEMPERED GLASS PANEL (1.5m WIDE x 10m TALL) SET IN
STAINLESS STEEL CHANNELS ANCHORED AT TOP & BOTTOM SET ON HIGH
DENSITY SETTING BLOCKS, PRE-FORMED GASKET AT INTERIOR AND
PRE-FORMED GASKET WITH CLEAR SILICON SEALANT AT EXTERIOR.
Lateral brace: GLASS FINS SET IN STAINLESS STEEL CHANNEL
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO HANGER - 10m TALL - BY
FULLY ENCLOSED STEEL SUPPORT AND STEEL ANCHORS. IGU PANELS WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRIT PATTERN AT 2nd & 3rd SURFACE
WITH AND WITHOUT SHADOW BOXES ATTACHED WITH STRUCTURAL SEALANT
AT ALL 4 SIDES. INTERMEDIATE HORIZONTAL MULLIONS FOR GLAZING SUPPORT
ONLY. INDEPENDENTLY SUPPORTED NON IGU PANELS INSTALLED WITHIN THE
SYSTEM AS INDICATED ON ELEVATION.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS, LOW-e PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES.
G-8
WALL TYPES - 8 and 9 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED G-9
DESIGN BUILT ALUM. STOREFRONT WITH CUSTOM PROFILED MULLIONS
SUPPORTED SLAB TO SLAB/SUPPORT FRAMING BY FULLY ENCLOSED STEEL
SUPPORT AND STEEL ANCHORS, GLASS PANELS ATTACHED WITH STRUCTURAL
SEALANT AT HORIZONTAL MULLIONS AND CAPTURED AT VERTICAL MULLIONS,
GRANITE BASE AND LOUVERS AT TOP. ALUM FRAMED ENTRANCES WITH FLOOR
CLOSURES AS INDICATED ON ELEVATIONS.
DESIGN BUILT PILKINGTON PLANAR (or approved equal) GLAZING SYSTEM WITH
LOUVERS AND ENTRANCES. GLAZING CONNECTORS AND GLASS PANELS PER
MANUFACTURER'S DETAILS.
G-10 GLASS PANELS FOR BALCONY & TERRACE RAILING.
G-11
WALL TYPE - 11 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO Drawing A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
TYPICAL METAL FINISHES NOTE:
1. PAINT DIS-SIMILAR METALS TO AVOID GALVANIC ACTION.
2. SEAL ALL SCREW PENETRATIONS. ALL METAL ATTACHMENTS SHALL BE
CONCEALED IN PUBLIC TRAFFIC AREAS AND SPACES.
3. ALL ALUM SURFACES EXPOSE TO WEATHER SHALL BE 70% (3 coat) AND
INTERIOR SURFACES SHALL BE 50% (2 coat) KYNAR - or approved equal - FINISH.
4. WELD BRACING ANGLES OR SECONDARY FRAMING AT THE BACK OF METAL
PANEL TO AVOID OIL CANNING.
5. ALL METAL SURFACE EXPOSE TO VIEW SHALL BE FINISHED SAME INCLUDING
BUT NOT LIMITED TO REVEALS, RETURNS & EDGES
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE WITH 50mm (min.) INSULATION WITH;
1) FACTORY APPLIED VAPOR BARRIER AT INDICATED LOCATIONS.
2) FACTORY APPLIED VAPOR BARRIER AND METAL PANEL AT
INDICATED LOCATION.
CUSTOM PROFILE EXTRUSIONS OR BENT ALUM INCLUDING BUT NOT
LIMITED TO TRIMS, COPINGS, DRIP EDGES, RAILING POSTS.
THICKNESS & SIZES AS INDICATED ON DRAWINGS.
MTL-3 740 mm DEEP SUN SHADE AT TOWER.
3mm THK. (nom.) ALUM. METAL BENT TO FORM 1.0m x 5.1m (nom.)
PANEL WITH 50mm (min.) INSULATION & FACTORY APPLIED VAPOR
BARRIER.
MTL-4
MTL-6
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE FOR EXTERIOR CLADDING, SOFFITS, COLUMN
COVERS AND MISC.
L-2
ST-1
ST-2
ST-3
STORM CLASS ALUM LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING: 1.0m x 2.0m (nom.) TYPICAL STONE PANEL,
INDEPENDENTLY SUPPORTED, OPEN JOINTS
ALT 1: 100mm THK. (nom., min.) HONED FINISH FRENCH LIMESTONE
ALT2: 50 mm THK. (nom.) HONED FINISH FRENCH LIMESTONE PANELS
ON 100mm THK. (nom.) CONC. BACK UP PANELS
ALT3: 30mm - 50mm THK. (nom.) GRANITE PANELS
ALT4: 125mm THK. (nom.) PRECAST PANELS
L-4
ZEROSITELINE FLUSH ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-5
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-6
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING AT GROUND LEVEL: 0.35m x 2.5m (nom.) PANEL
Stone: TO BE DECIDED
30mm THK. (nom.) 1.5m LONG POLISHED GRANITE BASE AT WALL
TYPES - SF01,SF02 & SF03.
150mm (min.) - 350mm (max.) HEIGHT OF BASE ABOVE FINISHED
FLOORING.
Stone color: TO BE DECIDED
G-7a NON IGU GLASS PANELS AT Jr. BALLROOM PRE-FUNCTION AREA
G-7b
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO DRAWING A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
REFER TO EXTERIOR WALL CONSULTANT'S SPECIFICATION FOR
GLASS MAKE UP, DETAILS AND PERFORMANCE INFORMATION.
G-11a
NON IGU GLASS PANELS AT MAIN BALLROOM PRE-FUNCTION
AREA
COMPOSITE SYSTEM OF STICK BUILT CURTAIN WALL AND ALUM. FRAMED
PUNCHED WINDOWS WITH CUSTOM PROFILED EXTERIOR TRIMS INSTALLED
WITHIN FIELD FOR STONE AND METAL PANELS.
ST-4
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT WALL TYPE - W08
Stone type & finish: TO BE DECIDED
ST-5
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT LOCATIONS INDICATED ON ELEVATIONS.
Stone type & finish: TO BE DECIDED
SC-1
50mm - 75mmTHK. (nom.) STUCCO, THICKNESS TO DEPEND ON
LOCATION AND FINISH.
Finish & Color: TO BE DECIDED
2 01/24/2011 2
04
04
07/01/2011 4
75
2
5
A
L
IG
N
A
L
IG
N
75
2
5
G-1
G-1
MTL-2 COPING
S. STL. COPING ANCHOR
- FASTENED TO REINF. CONC. WALL AND
STONE COPING @EACH COPING JOINT
ST-1 STONE CLADDING
MEMBRANE THRU -FLASHING
SEAL ALL PENETRATIONS
T.O. STONE
SEE WALL SECTIONS
ELASTOMERIC COATING OR
W.P. SEALANT APPROVED BY
MANUFACTURE
FRAME AS REQ'D.
CONT. DRIP EDGE & SEALANT
OR W.P.
SEALANT APPROVED BY
MANUFACTURE
OR W.P.
SEALANT APPROVED BY
MANUFACTURE
1
5
1
5
0
SLOPED
A
L
IG
N
A
L
IG
N
1
5
0
1
1
5
0
6
0
0
A425
WALL TYPE W5 SECTION
DETAILS
N
KEY PLAN
P
lo
t D
a
te
: 3
0
J
u
n
e
2
0
1
1
H
a
n
d
e
l A
s
s
o
c
ia
te
s
L
td

SHANGR/-LA AT
THE FORT, MAN/LA
FORT BONIFACIO
ARCHITECTS CO.
GF & PARTNERS
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8946281 to 85 FAX 63-2-8921861 E-MAIL: postmaster@gfparchitects.com
XAVIER ANTONIO J . GARCIA TEODORO H. NARCISO
TEOFILO A. SANTIAGO J R. ANNETTE F. GADDI-LIGANOR
CONSULTING ENGINEERS
DCCD ENGINEERING
112 SOL BUILDING, AMORSOLO STREET, LEGASPI VILLAGE, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8924586 TO 97 FAX 63-2-8182142 E-MAIL info@dccd.com
CORPORATION
IM MARTINEZ
UNIT 410 FEDMAN SUITES CONDOMINIUMBLDG. NO. 199-201 SALCEDO ST. LEGASPI VILLAGE
TELEPHONE 632-8932898 FAX 632-8925188 E-MAIL immce@pldtdsl.net
MAKATI CITY 1229 PHILIPPINES
SHANGRI-LA HOTEL, INC.
CONSULTING ENGINEERS
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL: pmt.slfm@shangri-la.com
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL:
20th FLOOR EASTERN CENTRAL PLAZA 3 YIU HING ROAD SHAUKEIWAN HONG KONG
RIDER LEVETT BUCKNALL
LTD.
HANDEL ASSOCIATES
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
CONSULTING ENGINEERS LTD
DESIMONE
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
J.P.R SDN. BHD.
12TH FLOOR, PENAS TOWER, 488A, J ALAN BURMA 10350, PENANG, MALAYSIA
A R C H I T E C T
:
:
:
:
ANNETTE F. GADDI-LIGANOR
SUPERSTRUCTURE ADVANCE TENDER SET
01
SCALE 1:10
TYP. ST-1 SECTION DETAIL @ LOUVER
EXTERIOR WALL TYPES
EXTERIOR MATERIALS
G-1
G-3
L-1
MTL-1
G-5
1. PROVIDE OPERABLE VENTS/WINDOWS FOR NATURAL VENTILATION AS MANDATED BY
APPLICABLE BUILDING CODES. THE LOCATION FOR OPERABLE VENTS/WINDOWS &
SIZES MAY CHANGE PER DESIGN DEVELOPMENT OF FACADE.
2. REFER TO DRAWING G001 FOR GENERAL EXTERIOR ENVELOPE NOTES.
3. REFER TO SERIES A1.00 FOR BUILDING PLANS.
4. REFER TO SERIES A4.00 FOR EXTERIOR WALL SECTIONS, TYPES AND DETAILS.
5. REFER TO SERIES A8.00 FOR GLASS PANELS SIZES.
6. LIGHTENING GROUNDING TO BE WIRED TO CURTAIN WALL. WIRING TO BE TAKEN TO
NEAREST COLUMN & CONDUIT TO RUN DOWN TO BUILDING FOUNDATION.
7. PROVIDE BUILT IN ELECTRIC SENSOR AT HOTEL RESIDENCE OPERABLE WINDOWS.
SENSOR IS TO BE HARDWIRED TO JBOX FOR CONNECTION TO FANCOIL UNIT. REFER
TO MEP DRAWINGS FOR DETAILS AND SPECIFICATION.
8. BACK-UP WALL SHOWN FOR DESIGN INTENT AND COORDINATION ONLY. REFER TO
STRUCTURAL CONSULTANT'S DRAWINGS FOR DIMENSION, DETAILS, AND MATERIAL
FOR BACK-UP WALL.
GENERAL NOTES
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT OR PRESSURE PLATES AS INDICATED
ON ELEVATIONS WITH;
1) 150 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS. (SEE DETAILED
DRAWINGS FOR PROFILE)
2) 740mm DEEP SUNSHADE DEVICE MECHANICALLY ATTACHED TO MULLIONS.
REINFORCE MULLIONS AS REQD.
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT AT HORIZONTAL MULLIONS AND
CAPTURED MULLIONS AT VERTICAL MULLIONS WITH ;
1) 200 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
VERTICAL MULLION AS INDICATED ON ELEVATIONS.
2) 100 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS.
DIMENSIONED STONE MASONRY FOR EXTERIOR CLADDING. STONE PANELS
ARE INDEPENDENTLY SUPPORTED AND ANCHORED TO BACKUP WALL WITH
NON-CORROSIVE SUPPORTS. 8mm -12mm OPEN JOINTS BETWEEN STONE
PANELS. NON-STAINNG, NON-SHRINK SEALANT AT MASONRY OPENING
BETWEEN METAL FRAME AND STONE PANELS. SILL, JAMB, SOFFIT AND SPECIAL
PROFILED PANELS MAY BE REQUIRED FOR OPENINGS IN THE FIELD OF STONE.
SEAL BACKSIDE OF STONE WITH MANUFACTURED APPROVED NON-STAINING
SEALER. ALL EXPOSED SURFACES OF THE STONE TO THE VIEW TO BE
FINISHED. FACTORY FINISHED DRIP EDGE AT THE BOTTOM STONE PANEL AT
SOFFITS AND LINTELS. PROVIDE STAINLESS STEEL OR METAL FLASHING AT
EVERY OTHER CONTINUOUS HORIZONTAL JOINT.
VISION GLASS: IGU WITH LOW-e COAT (2nd surface)
Tower Glass Color & Coating: TO BE DECIDED
Podium Glass Color & Coating: TO BE DECIDED
SPANDREL GLASS INDICATION ON THE DRAWINGS.
Glass coating, Make up & Color: Same as G-1
Paint Color: TO BE DECIDED
PILKINGTON SYSTEM (or approved equal)GLASS PANELS FOR ICONIC
RETAIL AREA
Glass Make Up: Per manufacturer's design recommendation
G-6
G-2
SHADOW BOX INDICATION ON THE DRAWINGS
Vision Glass, coating, Make up & Color: Same as G-1
MTL-2
G-4
STOREFRONT GLASS PANELS:
WALL TYPE - 6 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED
G-7
WALL TYPE - 7 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO ELEVATIONS)
Glass Color, Coating & FRIT pattern: TO BE DECIDED
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS AND SHADOW BOXES ATTACHED
WITH STRUCTURAL SEALANT AT ALL 4 SIDES.
DESIGN BUILT STICK SYSTEM CURTAIN WALL INCLUDING EXTRUDED ALUM.
MULLIONS, METAL PANELS, LOW-e IGU PANELS ATTACHED WITH STRUCTURAL
SEALANT AND CAPTURED MULLIONS. CONNECT WITH W 02 AND W03 AS
REQUIRED. (ADDITIONAL MECHANICAL ATTACHMENT FOR METAL PANEL
SUGGESTED.)
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. HORIZONTAL MULLIONS ANCHORED
WITH SHEAR BLOCKS OR STEEL INSERTS. GLASS PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED METAL FACIA
PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER SLAB EDGE AND
PERIMETER BEAM.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. LOW-e IGUs PANELS AND IGUs WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRITT PATTERN AT 2nd & 3rd SURFACE
ATTACHED WITH STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED
METAL FACIA PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER
SLAB EDGE AND PERIMETER BEAM.
30mm THK. (nom.)TEMPERED GLASS PANEL (1.5m WIDE x 10m TALL) SET IN
STAINLESS STEEL CHANNELS ANCHORED AT TOP & BOTTOM SET ON HIGH
DENSITY SETTING BLOCKS, PRE-FORMED GASKET AT INTERIOR AND
PRE-FORMED GASKET WITH CLEAR SILICON SEALANT AT EXTERIOR.
Lateral brace: GLASS FINS SET IN STAINLESS STEEL CHANNEL
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO HANGER - 10m TALL - BY
FULLY ENCLOSED STEEL SUPPORT AND STEEL ANCHORS. IGU PANELS WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRIT PATTERN AT 2nd & 3rd SURFACE
WITH AND WITHOUT SHADOW BOXES ATTACHED WITH STRUCTURAL SEALANT
AT ALL 4 SIDES. INTERMEDIATE HORIZONTAL MULLIONS FOR GLAZING SUPPORT
ONLY. INDEPENDENTLY SUPPORTED NON IGU PANELS INSTALLED WITHIN THE
SYSTEM AS INDICATED ON ELEVATION.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS, LOW-e PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES.
G-8
WALL TYPES - 8 and 9 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED G-9
DESIGN BUILT ALUM. STOREFRONT WITH CUSTOM PROFILED MULLIONS
SUPPORTED SLAB TO SLAB/SUPPORT FRAMING BY FULLY ENCLOSED STEEL
SUPPORT AND STEEL ANCHORS, GLASS PANELS ATTACHED WITH STRUCTURAL
SEALANT AT HORIZONTAL MULLIONS AND CAPTURED AT VERTICAL MULLIONS,
GRANITE BASE AND LOUVERS AT TOP. ALUM FRAMED ENTRANCES WITH FLOOR
CLOSURES AS INDICATED ON ELEVATIONS.
DESIGN BUILT PILKINGTON PLANAR (or approved equal) GLAZING SYSTEM WITH
LOUVERS AND ENTRANCES. GLAZING CONNECTORS AND GLASS PANELS PER
MANUFACTURER'S DETAILS.
G-10 GLASS PANELS FOR BALCONY & TERRACE RAILING.
G-11
WALL TYPE - 11 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO Drawing A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
TYPICAL METAL FINISHES NOTE:
1. PAINT DIS-SIMILAR METALS TO AVOID GALVANIC ACTION.
2. SEAL ALL SCREW PENETRATIONS. ALL METAL ATTACHMENTS SHALL BE
CONCEALED IN PUBLIC TRAFFIC AREAS AND SPACES.
3. ALL ALUM SURFACES EXPOSE TO WEATHER SHALL BE 70% (3 coat) AND
INTERIOR SURFACES SHALL BE 50% (2 coat) KYNAR - or approved equal - FINISH.
4. WELD BRACING ANGLES OR SECONDARY FRAMING AT THE BACK OF METAL
PANEL TO AVOID OIL CANNING.
5. ALL METAL SURFACE EXPOSE TO VIEW SHALL BE FINISHED SAME INCLUDING
BUT NOT LIMITED TO REVEALS, RETURNS & EDGES
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE WITH 50mm (min.) INSULATION WITH;
1) FACTORY APPLIED VAPOR BARRIER AT INDICATED LOCATIONS.
2) FACTORY APPLIED VAPOR BARRIER AND METAL PANEL AT
INDICATED LOCATION.
CUSTOM PROFILE EXTRUSIONS OR BENT ALUM INCLUDING BUT NOT
LIMITED TO TRIMS, COPINGS, DRIP EDGES, RAILING POSTS.
THICKNESS & SIZES AS INDICATED ON DRAWINGS.
MTL-3 740 mm DEEP SUN SHADE AT TOWER.
3mm THK. (nom.) ALUM. METAL BENT TO FORM 1.0m x 5.1m (nom.)
PANEL WITH 50mm (min.) INSULATION & FACTORY APPLIED VAPOR
BARRIER.
MTL-4
MTL-6
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE FOR EXTERIOR CLADDING, SOFFITS, COLUMN
COVERS AND MISC.
L-2
ST-1
ST-2
ST-3
STORM CLASS ALUM LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING: 1.0m x 2.0m (nom.) TYPICAL STONE PANEL,
INDEPENDENTLY SUPPORTED, OPEN JOINTS
ALT 1: 100mm THK. (nom., min.) HONED FINISH FRENCH LIMESTONE
ALT2: 50 mm THK. (nom.) HONED FINISH FRENCH LIMESTONE PANELS
ON 100mm THK. (nom.) CONC. BACK UP PANELS
ALT3: 30mm - 50mm THK. (nom.) GRANITE PANELS
ALT4: 125mm THK. (nom.) PRECAST PANELS
L-4
ZEROSITELINE FLUSH ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-5
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-6
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING AT GROUND LEVEL: 0.35m x 2.5m (nom.) PANEL
Stone: TO BE DECIDED
30mm THK. (nom.) 1.5m LONG POLISHED GRANITE BASE AT WALL
TYPES - SF01,SF02 & SF03.
150mm (min.) - 350mm (max.) HEIGHT OF BASE ABOVE FINISHED
FLOORING.
Stone color: TO BE DECIDED
G-7a NON IGU GLASS PANELS AT Jr. BALLROOM PRE-FUNCTION AREA
G-7b
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO DRAWING A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
REFER TO EXTERIOR WALL CONSULTANT'S SPECIFICATION FOR
GLASS MAKE UP, DETAILS AND PERFORMANCE INFORMATION.
G-11a
NON IGU GLASS PANELS AT MAIN BALLROOM PRE-FUNCTION
AREA
COMPOSITE SYSTEM OF STICK BUILT CURTAIN WALL AND ALUM. FRAMED
PUNCHED WINDOWS WITH CUSTOM PROFILED EXTERIOR TRIMS INSTALLED
WITHIN FIELD FOR STONE AND METAL PANELS.
ST-4
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT WALL TYPE - W08
Stone type & finish: TO BE DECIDED
ST-5
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT LOCATIONS INDICATED ON ELEVATIONS.
Stone type & finish: TO BE DECIDED
SC-1
50mm - 75mmTHK. (nom.) STUCCO, THICKNESS TO DEPEND ON
LOCATION AND FINISH.
Finish & Color: TO BE DECIDED
04
SCALE 1:10
TYP. ST-1 SECTION DETAIL @ 35mm STONE
05
SCALE 1:10
TYP. ST-1 SECTION DETAIL @ 35mm STONE
02
SCALE 1:10
TYP. ST-1 SECTION DETAIL @ LOUVER
07
SCALE 1:10
TYP. ST-1 SECTION DETAIL AT SILL
08
SCALE 1:10
TYP. ST-1 SECTION DETAIL AT HEADER / ROOF
09
SCALE 1:10
TYP. ST-1 SECTION DETAIL AT PARAPET
10
SCALE 1:10
TYP. ST-1 SECTION DETAIL AT LOUVER
11
SCALE 1:10
TYP. MTL. SCREEN SECTION DETAIL AT SILL
12
SCALE 1:10
TYP. MTL. SCREEN SECTION DETAIL AT BEAM
13
SCALE 1:10
TYP. MTL. SCREEN SECTION DETAIL AT HEADDER
03
SCALE 1:10
TYP. SC-1 SECTION DETAIL @ PARAPET
07/01/2011 4
OR W.P.
SEALANT APPROVED BY
MANUFACTURE
S. STL. STONE ANCHOR
ST-1 STONE CLADDING
SEE ELEV. FOR WINDOW TYPES
SEALANT & BACKER ROD
BACK-UP REINF. CONC. WALL
OR W.P.
SEALANT APPROVED BY
MANUFACTURE
7
5
150
OR W.P.
SEALANT APPROVED BY
MANUFACTURE
OR W.P.
SEALANT APPROVED BY
MANUFACTURE
BACK-UP REINF. CONC. WALL
G-12
A426
WALL TYPE W5 PLAN
DETAILS
N
KEY PLAN
P
lo
t D
a
te
: 3
0
J
u
n
e
2
0
1
1
H
a
n
d
e
l A
s
s
o
c
ia
te
s
L
td

SHANGR/-LA AT
THE FORT, MAN/LA
FORT BONIFACIO
ARCHITECTS CO.
GF & PARTNERS
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8946281 to 85 FAX 63-2-8921861 E-MAIL: postmaster@gfparchitects.com
XAVIER ANTONIO J . GARCIA TEODORO H. NARCISO
TEOFILO A. SANTIAGO J R. ANNETTE F. GADDI-LIGANOR
CONSULTING ENGINEERS
DCCD ENGINEERING
112 SOL BUILDING, AMORSOLO STREET, LEGASPI VILLAGE, MAKATI CITY, PHILIPPINES
TELEPHONE 63-2-8924586 TO 97 FAX 63-2-8182142 E-MAIL info@dccd.com
CORPORATION
IM MARTINEZ
UNIT 410 FEDMAN SUITES CONDOMINIUMBLDG. NO. 199-201 SALCEDO ST. LEGASPI VILLAGE
TELEPHONE 632-8932898 FAX 632-8925188 E-MAIL immce@pldtdsl.net
MAKATI CITY 1229 PHILIPPINES
SHANGRI-LA HOTEL, INC.
CONSULTING ENGINEERS
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL: pmt.slfm@shangri-la.com
30th STREET, CORNER 5TH AVENUE, CRESCENT PARK WEST DISTRICT, BONIFACIO
GLOBAL CITY,TAGUIG CITY 1634, PHILIPPINES
TELEPHONE FAX E-MAIL:
20th FLOOR EASTERN CENTRAL PLAZA 3 YIU HING ROAD SHAUKEIWAN HONG KONG
RIDER LEVETT BUCKNALL
LTD.
HANDEL ASSOCIATES
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
CONSULTING ENGINEERS LTD
DESIMONE
SUITE 1408, HARCOURT HOUSE, 39 GLOUCESTER ROAD, WANCHAI, HONG KONG
J.P.R SDN. BHD.
12TH FLOOR, PENAS TOWER, 488A, J ALAN BURMA 10350, PENANG, MALAYSIA
A R C H I T E C T
:
:
:
:
ANNETTE F. GADDI-LIGANOR
SUPERSTRUCTURE ADVANCE TENDER SET
EXTERIOR WALL TYPES
EXTERIOR MATERIALS
G-1
G-3
L-1
MTL-1
G-5
1. PROVIDE OPERABLE VENTS/WINDOWS FOR NATURAL VENTILATION AS MANDATED BY
APPLICABLE BUILDING CODES. THE LOCATION FOR OPERABLE VENTS/WINDOWS &
SIZES MAY CHANGE PER DESIGN DEVELOPMENT OF FACADE.
2. REFER TO DRAWING G001 FOR GENERAL EXTERIOR ENVELOPE NOTES.
3. REFER TO SERIES A1.00 FOR BUILDING PLANS.
4. REFER TO SERIES A4.00 FOR EXTERIOR WALL SECTIONS, TYPES AND DETAILS.
5. REFER TO SERIES A8.00 FOR GLASS PANELS SIZES.
6. LIGHTENING GROUNDING TO BE WIRED TO CURTAIN WALL. WIRING TO BE TAKEN TO
NEAREST COLUMN & CONDUIT TO RUN DOWN TO BUILDING FOUNDATION.
7. PROVIDE BUILT IN ELECTRIC SENSOR AT HOTEL RESIDENCE OPERABLE WINDOWS.
SENSOR IS TO BE HARDWIRED TO JBOX FOR CONNECTION TO FANCOIL UNIT. REFER
TO MEP DRAWINGS FOR DETAILS AND SPECIFICATION.
8. BACK-UP WALL SHOWN FOR DESIGN INTENT AND COORDINATION ONLY. REFER TO
STRUCTURAL CONSULTANT'S DRAWINGS FOR DIMENSION, DETAILS, AND MATERIAL
FOR BACK-UP WALL.
GENERAL NOTES
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT OR PRESSURE PLATES AS INDICATED
ON ELEVATIONS WITH;
1) 150 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS. (SEE DETAILED
DRAWINGS FOR PROFILE)
2) 740mm DEEP SUNSHADE DEVICE MECHANICALLY ATTACHED TO MULLIONS.
REINFORCE MULLIONS AS REQD.
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS, METAL PANELS & SPANDREL PANELS
ATTACHED WITH STRUCTURAL SEALANT AT HORIZONTAL MULLIONS AND
CAPTURED MULLIONS AT VERTICAL MULLIONS WITH ;
1) 200 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
VERTICAL MULLION AS INDICATED ON ELEVATIONS.
2) 100 mm DEEP CUSTOM PROFILED TRIM MECHANICALLY ATTACHED TO
HORIZONTAL MULLION AS INDICATED ON ELEVATIONS.
DIMENSIONED STONE MASONRY FOR EXTERIOR CLADDING. STONE PANELS
ARE INDEPENDENTLY SUPPORTED AND ANCHORED TO BACKUP WALL WITH
NON-CORROSIVE SUPPORTS. 8mm -12mm OPEN JOINTS BETWEEN STONE
PANELS. NON-STAINNG, NON-SHRINK SEALANT AT MASONRY OPENING
BETWEEN METAL FRAME AND STONE PANELS. SILL, JAMB, SOFFIT AND SPECIAL
PROFILED PANELS MAY BE REQUIRED FOR OPENINGS IN THE FIELD OF STONE.
SEAL BACKSIDE OF STONE WITH MANUFACTURED APPROVED NON-STAINING
SEALER. ALL EXPOSED SURFACES OF THE STONE TO THE VIEW TO BE
FINISHED. FACTORY FINISHED DRIP EDGE AT THE BOTTOM STONE PANEL AT
SOFFITS AND LINTELS. PROVIDE STAINLESS STEEL OR METAL FLASHING AT
EVERY OTHER CONTINUOUS HORIZONTAL JOINT.
VISION GLASS: IGU WITH LOW-e COAT (2nd surface)
Tower Glass Color & Coating: TO BE DECIDED
Podium Glass Color & Coating: TO BE DECIDED
SPANDREL GLASS INDICATION ON THE DRAWINGS.
Glass coating, Make up & Color: Same as G-1
Paint Color: TO BE DECIDED
PILKINGTON SYSTEM (or approved equal)GLASS PANELS FOR ICONIC
RETAIL AREA
Glass Make Up: Per manufacturer's design recommendation
G-6
G-2
SHADOW BOX INDICATION ON THE DRAWINGS
Vision Glass, coating, Make up & Color: Same as G-1
MTL-2
G-4
STOREFRONT GLASS PANELS:
WALL TYPE - 6 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED
G-7
WALL TYPE - 7 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO ELEVATIONS)
Glass Color, Coating & FRIT pattern: TO BE DECIDED
UNITIZED CURTAIN WALL SYSTEM INCLUDING EXTRUDED ALUM. MULLIONS,
OPERABLE WINDOWS, LOW-e IGU PANELS AND SHADOW BOXES ATTACHED
WITH STRUCTURAL SEALANT AT ALL 4 SIDES.
DESIGN BUILT STICK SYSTEM CURTAIN WALL INCLUDING EXTRUDED ALUM.
MULLIONS, METAL PANELS, LOW-e IGU PANELS ATTACHED WITH STRUCTURAL
SEALANT AND CAPTURED MULLIONS. CONNECT WITH W 02 AND W03 AS
REQUIRED. (ADDITIONAL MECHANICAL ATTACHMENT FOR METAL PANEL
SUGGESTED.)
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. HORIZONTAL MULLIONS ANCHORED
WITH SHEAR BLOCKS OR STEEL INSERTS. GLASS PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED METAL FACIA
PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER SLAB EDGE AND
PERIMETER BEAM.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS. LOW-e IGUs PANELS AND IGUs WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRITT PATTERN AT 2nd & 3rd SURFACE
ATTACHED WITH STRUCTURAL SEALANT AT ALL 4 SIDES. CUSTOM PROFILED
METAL FACIA PANEL INSTALLED BETWEEN VERTICAL MULLIONS TO COVER
SLAB EDGE AND PERIMETER BEAM.
30mm THK. (nom.)TEMPERED GLASS PANEL (1.5m WIDE x 10m TALL) SET IN
STAINLESS STEEL CHANNELS ANCHORED AT TOP & BOTTOM SET ON HIGH
DENSITY SETTING BLOCKS, PRE-FORMED GASKET AT INTERIOR AND
PRE-FORMED GASKET WITH CLEAR SILICON SEALANT AT EXTERIOR.
Lateral brace: GLASS FINS SET IN STAINLESS STEEL CHANNEL
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO HANGER - 10m TALL - BY
FULLY ENCLOSED STEEL SUPPORT AND STEEL ANCHORS. IGU PANELS WITH
CUSTOM DESIGN CERAMIC/SILK SCREEN FRIT PATTERN AT 2nd & 3rd SURFACE
WITH AND WITHOUT SHADOW BOXES ATTACHED WITH STRUCTURAL SEALANT
AT ALL 4 SIDES. INTERMEDIATE HORIZONTAL MULLIONS FOR GLAZING SUPPORT
ONLY. INDEPENDENTLY SUPPORTED NON IGU PANELS INSTALLED WITHIN THE
SYSTEM AS INDICATED ON ELEVATION.
DESIGN BUILT (ON SITE OR PRE-FAB) ALUM. STICK SYSTEM CURTAIN WALL WITH
CUSTOM PROFILED MULLIONS SUPPORTED SLAB TO SLAB BY FULLY ENCLOSED
STEEL SUPPORT AND STEEL ANCHORS, LOW-e PANELS ATTACHED WITH
STRUCTURAL SEALANT AT ALL 4 SIDES.
G-8
WALL TYPES - 8 and 9 GLASS PANELS:
Glass Color & Coating: TO BE DECIDED G-9
DESIGN BUILT ALUM. STOREFRONT WITH CUSTOM PROFILED MULLIONS
SUPPORTED SLAB TO SLAB/SUPPORT FRAMING BY FULLY ENCLOSED STEEL
SUPPORT AND STEEL ANCHORS, GLASS PANELS ATTACHED WITH STRUCTURAL
SEALANT AT HORIZONTAL MULLIONS AND CAPTURED AT VERTICAL MULLIONS,
GRANITE BASE AND LOUVERS AT TOP. ALUM FRAMED ENTRANCES WITH FLOOR
CLOSURES AS INDICATED ON ELEVATIONS.
DESIGN BUILT PILKINGTON PLANAR (or approved equal) GLAZING SYSTEM WITH
LOUVERS AND ENTRANCES. GLAZING CONNECTORS AND GLASS PANELS PER
MANUFACTURER'S DETAILS.
G-10 GLASS PANELS FOR BALCONY & TERRACE RAILING.
G-11
WALL TYPE - 11 GLASS PANELS:
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO Drawing A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
TYPICAL METAL FINISHES NOTE:
1. PAINT DIS-SIMILAR METALS TO AVOID GALVANIC ACTION.
2. SEAL ALL SCREW PENETRATIONS. ALL METAL ATTACHMENTS SHALL BE
CONCEALED IN PUBLIC TRAFFIC AREAS AND SPACES.
3. ALL ALUM SURFACES EXPOSE TO WEATHER SHALL BE 70% (3 coat) AND
INTERIOR SURFACES SHALL BE 50% (2 coat) KYNAR - or approved equal - FINISH.
4. WELD BRACING ANGLES OR SECONDARY FRAMING AT THE BACK OF METAL
PANEL TO AVOID OIL CANNING.
5. ALL METAL SURFACE EXPOSE TO VIEW SHALL BE FINISHED SAME INCLUDING
BUT NOT LIMITED TO REVEALS, RETURNS & EDGES
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE WITH 50mm (min.) INSULATION WITH;
1) FACTORY APPLIED VAPOR BARRIER AT INDICATED LOCATIONS.
2) FACTORY APPLIED VAPOR BARRIER AND METAL PANEL AT
INDICATED LOCATION.
CUSTOM PROFILE EXTRUSIONS OR BENT ALUM INCLUDING BUT NOT
LIMITED TO TRIMS, COPINGS, DRIP EDGES, RAILING POSTS.
THICKNESS & SIZES AS INDICATED ON DRAWINGS.
MTL-3 740 mm DEEP SUN SHADE AT TOWER.
3mm THK. (nom.) ALUM. METAL BENT TO FORM 1.0m x 5.1m (nom.)
PANEL WITH 50mm (min.) INSULATION & FACTORY APPLIED VAPOR
BARRIER.
MTL-4
MTL-6
3mm THK. (nom.) ALUM. METAL BENT TO FORM PANEL PER
INDICATED SIZE FOR EXTERIOR CLADDING, SOFFITS, COLUMN
COVERS AND MISC.
L-2
ST-1
ST-2
ST-3
STORM CLASS ALUM LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING: 1.0m x 2.0m (nom.) TYPICAL STONE PANEL,
INDEPENDENTLY SUPPORTED, OPEN JOINTS
ALT 1: 100mm THK. (nom., min.) HONED FINISH FRENCH LIMESTONE
ALT2: 50 mm THK. (nom.) HONED FINISH FRENCH LIMESTONE PANELS
ON 100mm THK. (nom.) CONC. BACK UP PANELS
ALT3: 30mm - 50mm THK. (nom.) GRANITE PANELS
ALT4: 125mm THK. (nom.) PRECAST PANELS
L-4
ZEROSITELINE FLUSH ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-5
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
L-6
EXTRUDED ALUM. LOUVERS, 50% (min.) OPEN AREA
Color & style: TO BE DECIDED
EXTERIOR CLADDING AT GROUND LEVEL: 0.35m x 2.5m (nom.) PANEL
Stone: TO BE DECIDED
30mm THK. (nom.) 1.5m LONG POLISHED GRANITE BASE AT WALL
TYPES - SF01,SF02 & SF03.
150mm (min.) - 350mm (max.) HEIGHT OF BASE ABOVE FINISHED
FLOORING.
Stone color: TO BE DECIDED
G-7a NON IGU GLASS PANELS AT Jr. BALLROOM PRE-FUNCTION AREA
G-7b
IGU WITH LOW-e COAT (2nd surface) WITH CERAMIC FRITT PATTERN
(2nd & 3rd surface). (REFER TO DRAWING A-822)
Glass Color, Coating & FRIT parttern: TO BE DECIDED
REFER TO EXTERIOR WALL CONSULTANT'S SPECIFICATION FOR
GLASS MAKE UP, DETAILS AND PERFORMANCE INFORMATION.
G-11a
NON IGU GLASS PANELS AT MAIN BALLROOM PRE-FUNCTION
AREA
COMPOSITE SYSTEM OF STICK BUILT CURTAIN WALL AND ALUM. FRAMED
PUNCHED WINDOWS WITH CUSTOM PROFILED EXTERIOR TRIMS INSTALLED
WITHIN FIELD FOR STONE AND METAL PANELS.
ST-4
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT WALL TYPE - W08
Stone type & finish: TO BE DECIDED
ST-5
30mm THK. (nom.) INDEPENDENTLY SUPPORTED GRANITE PANELS
AT LOCATIONS INDICATED ON ELEVATIONS.
Stone type & finish: TO BE DECIDED
SC-1
50mm - 75mmTHK. (nom.) STUCCO, THICKNESS TO DEPEND ON
LOCATION AND FINISH.
Finish & Color: TO BE DECIDED
01
SCALE 1:10
TYP. ST-1 PLAN DETAIL @ LOUVER
03
SCALE 1:10
TYP. ST-1 PLAN DETAIL @ 35mm STONE
04
SCALE 1:10
TYP. ST-1 PLAN DETAIL @ WINDOW
02
SCALE 1:10
TYP. ST-1 PLAN DETAIL @ LOUVER
09
SCALE 1:10
ST-1 PLAN DETAIL @ NORTHWEST
05
SCALE 1:10
TYP. ST-1 PLAN DETAIL @ PERF. METAL PANEL
06
SCALE 1:10
TYP. ST-1 PLAN DETAIL @ PERF. METAL PANEL
07/01/2011 4
07
SCALE 1:10
TYP. ST-1 PLAN DETAIL @ LOUVER
08
SCALE 1:10
TYP. ST-1 PLAN DETAIL @ W12