Вы находитесь на странице: 1из 12

Design guide www.etisalat.

ae

Subject Page
Introduction 2
General telecom requirements 3
Civil requirements applicable for all types of buildings 3
Entry box 3
Entry pipes 3
Main telecom room 4
Floor telecom room 4
Roof-top telecom room 4
Risers from main telecom room to individual floors 5
Floor distribution box 5
Flat distribution-from indoor equipment cabinet 6
Villa floor distribution-from indoor equipment cabinet 6
Installation of in-building fibre drop cables 6
High-rise buildings 6
Single villas 7
Etisalat telecom requirements 7
Etisalat telecom requirements-Table 1 7
Etisalat telecom requirements-Table 2 8
Structured Cabling System (SCS) 9
Cabling & termination 9
Telecommunication cabling 9
Telecommunication socket 9
Accessories 10
Horizontal subsystem (UTP Cables) 10
Cable capacities in trays conduits 11
Indoor equipment cabinet 19” 11
A) Free standing types 11
B) Wall-mounted type cabinets 12
Under-floor systems 12
Main elements of under-floor raceway systems 12
Protection from electromagnetic interference 13
Electrical requirements 15
Important notes 15
List of annexures 16

Index
Design guide www.etisalat.ae

Introduction

Telecommunication is now an integral part of social, Etisalat can be well-placed to meet these challenges ahead
economic and political issues of the world. Networks of and meet the varied needs of our local and international
the future will be digital and intelligent and will offer high customers and pave the way for the region’s new dynamism
transmission capacity and flexible bandwidth; in addition, in the telecommunications industry well into the 21st
they will be easily accessed and connected while its century.
services will be personal and tailored to individual needs.
These will allow us to interact in ways previously not As technology and mode of transport are changing fast, a
possible - available at any time and any place. In addition broad approach to suit all future type of services will have
to providing entertainment and business services, networks to be borne in mind, while designing the infrastructures for
of the future will provide education, health and other buildings. A properly designed building with clear Access
public services. Path supports the triple play services, viz telephony, data
and video services. Also, supports future advanced services,
Major advances in communications technology have warranting higher speeds and higher bandwidth, planned to
substantially widened the range of services carried by be available in near future, for faster provision of services.
the network. Satellites, microwave radio, optical cable
links, digital switching and transmission, offer a potential The present booklet is to provide guidelines for consultants,
for the improvement of quality and for the extension of contractors and the details on the in-building facilities
access to the most remote areas. The pace of technological required to be considered at the design stage.
change is increasing while the magnitude of demands the
future will make on our creativity and capacity to adapt The details provided are a general insight and the minimum
is great. Customers will demand more than just state- requirements of Etisalat for the new buildings, primarily to
of-the-art technology; they will want convenience and develop and deploy FTTX (Fibre to Home), based on GPON
increased control in their lives that affordable information technology.
access can provide. While businesses will look for total
telecommunications solutions that will not only enable
them to remain productive and compete globally but will
also give them a competitive edge.

1 Introduction 2
Design guide www.etisalat.ae

General telecom requirements contractors must not deviate from the stipulated location • Entry pipes must be assigned, exclusively for Etisalat • If the telecom room is proposed in the basement, an
telecommunication services automatic sump draining system must be provided to
To provide telecom services, the internal concealed pipe • An earth rod must be provided at the entry box. The handle water seepages
and other associated requirements vary for the different required earth resistance should not exceed more than 5 • Entry pipes must be provided with a draw rope made of
building types. The various types of buildings are grouped ohms nylon of minimum 6 mm diameter • The duct entry to building must be sealed air and water
as commercial buildings, residential towers, ware houses, tight
• For entry box size details please refer to Table No. 1 • For the number and size of entry pipes, for the various
medium high-rise buildings, shopping complexes, retail
types of buildings, please refer to Table 1 • For the main telecom room size, please refer Table No. 1
houses, row houses, independent villas, campus villas,
Entry pipes (Lead-in ducts)
labour camps, mosques, petrol pumps, etc. Main telecom room Floor telecom closet
The building owners, builders, property developers, The entry pipes are uPVC ducts. These ducts are to be
extended from the entry box towards premises and towards Main telecom room should be a dedicated room. This is to Floor telecom closet is a dedicated closet and required on
consultants and contractors are advised to provide the be provided either on the ground floor or basement or in
various in–building requirements, as applicable, to ensure Etisalat line plant location. each floor for the purpose of routing and/or terminating
the first floor or mezzanine floor of the building for the telecommunication cables. The room should be exclusively
timely provision of services. purpose of terminating telecommunication cables and to
• Entry pipes should be laid at a depth of 60 cm from the for Etisalat use
proposed finished paving level. The entry pipe must be house the present & future telecom equipment. The room
Civil requirements applicable for all types must be exclusively for Etisalat use
protected with concrete to prevent damages • The closet must readily be accessible to Etisalat personnel
of buildings
and equipment 24 hr./day, all the days, round the clock and
• Entry pipe should be extended to the entry box and • The room must be easily accessible to Etisalat Personnel the closet, clean dry, and free from dust and secured from
Entry box 24 hr./day, (all days including weekends). The room
beyond to the nearest existing Etisalat plant location, or 1 unauthorized entry
meter from plot limit or as advised by Etisalat must be clean, dry and free from dust and secured from
Entry box is an underground joint box built, exclusively to unauthorized entry
allow installation of Etisalat underground cable network to • The door opening for the closet should swing outwards,
• The entry pipe should be of uPVC material and of black when opened
the customer’s premises. color • Adequate lighting and minimum of four 20 amp and
240 volt A.C. Mains outlet from a dedicated circuit breaker • For the floor telecom closet size, please refer Table No. 1
• The entry box is a reinforced concrete structure, with a • The open ends of the entry pipe must be properly sealed, should be provided
heavy duty Ductile Iron Frame and Cover of rating grade ‘A’ to prevent entry of sub-soil materials and ingress of water
and size is 60x60x80 cm. The cover shall have marking as Roof-top telecom room
• The room must be air-conditioned and a “raised floor” of
“Telephones” • Location of entry pipes must be clearly marked, above minimum 30 cm should be provided if required, depending
Roof-top telecom room, is a dedicated room to be provided
ground for easy location on the telecom room usage
• The location of the entry box, depends on the location of on the roof-top of the proposed multi-storey buildings,
existing/proposed Etisalat external line plant • Building contractors shall be responsible to locate the • The room must be provided with a good earth rod of not exclusively for Etisalat use and secured from unauthorized
installed entry pipes on site, if requested by Etisalat more than 5 ohms entry. The minimum roof-top telecom room size should be
• The entry box should be constructed at a maximum 3(L) x 3(W) x 3(H) meter
distance of 1 meter from plot line. If it is not practical to • No right-angled sharp bends should be installed through • The door opening for the room should swing outwards
install within the plot, then install it outside the plot. Make • The floor loading of this area must be maximum possible,
out the duct length, except one wide-angle, long radius
sure it touches the boundary wall • The floor, roof and surrounding wall of the telecom room, to support future installation of telecommunications
bend (factory made) at the terminating end of the duct,
should be free of any concealed water/drainage pipes and equipment
inside the main telecom room. Alternatively, at the location
• Due to the variables involved, it is essential to consult air-conditioning ducts passing through
Etisalat at the design stage, to decide the location of the wide angle bend, a cable pull box of minimum size • An opening of size 60x40 cm to be provided on the wall
of the entry box and entry pipe. The consultants/ 600(L) x 700(W) x 800(D) mm must be provided • The room must be provided with an emergency light, a of the room, facing the terrace, 50 cm below the room
smoke detector and a fire alarm ceiling

3 4
Design guide www.etisalat.ae

• The location of the room should be within the vertical The towers must be inter-connected at the main telecom • A single conduit of at least 25 mm (1 inch) internal dia., Villa distribution
structure of the building, with due considerations for load room, by separate cable trays of minimum 2 nos. and size black and of uPVC material should be provided from each - from indoor equipment cabinet
safety provisions and to extend related facilities required 200x50 mm or through floor raceways passing through floor distribution box to the indoor equipment cabinet of
such as air-conditioning, 3-phase power (Distribution a common area between the two buildings. The size of each office, residence, flat and other independent areas in • A secured indoor equipment cabinet, should be of
Board) DB, earthing less than 5 ohms, adequate lighting, the floor raceways is to be decided at the design stage by the same floor minimum size 12 U and width 600 mm and depth 515 mm
one 13 amp 240 v AC power socket and one telephone Etisalat. The same requirements also apply to mezzanine to house the Optical Network Unit (ONU), power sockets
socket and penthouse floors. The telecom cable trays should have • Etisalat should be consulted to enhance the requirements, and patch panel/IDC modules and battery. The cabinet
adequate separation from electrical cable trays. Electrical if the building is designed for commercial use should be flush mounted on wall. The cabinet should be
• The room must be provided with an emergency light, a cable trays should not cross the telecom cable trays. dedicated on each villa and to be sited in a secured place.
smoke detector and a fire alarm Flat distribution The location must be suitable for technician’s access, when
Floor distribution box – from indoor equipment cabinet required
• The room must readily be accessible to Etisalat
personnel and equipment 24 hr every day, all the days, Floor distribution boxes are metallic boxes, concealed, • A secured indoor equipment cabinet should be of • A secured distribution box of size 30 (L)x30 (H)x15 (W) cm
round the clock and the room must be clean, dry and free located on the wall, where the internal conduit from every minimum size 12 U and width 600 mm and depth 515 mm flush mounted on wall is required in every floor of the villa,
from dust flat is terminated. These empty boxes, should be located to house the Optical Network Unit (ONU), power sockets for distributing SCS, from the indoor cabinet
close to the risers and can be more than one, depending and patch panel/IDC modules and battery. The cabinet
Risers from main telecom room upon the number of flats and conduits proposed to be should be flush mounted on wall. The cabinet should be • The floor distribution box should be kept at a convenient
to individual floors terminated. These distribution boxes facilitate to route the dedicated to each office/residential flat and to be sited in a and easily accessible location where the floor distribution
fibre optic cables to the premises direct and the number of secured place. The location shall be suitable for technician’s conduits are terminated. It should be installed at a height
The risers are required in multiple-storey buildings for cables corresponds to the number of flat/premises. access, when required between 40 cm and 120 cm above the finished floor level
the installation of telecom fibre optic cables from main
telecom room to other floors, as detailed below:- • The distribution boxes should be of size not less than • The location of the indoor equipment cabinet should be
30(L) X 30(H) X 15(D) flush mounted on wall and should • The distribution boxes on different floors of a villa should
at a common point, where all the internal conduits meet be connected through a PVC conduit, of a 50 mm diameter
• Galvanized slotted iron cable trays (minimum 200x50 be fixed inside the telecom closet of each floor. A suitable and the Structured Cabling System (SCS) on a star topology
mm HDRF (Heavy Duty, Return Flange) should be provided hinged cover must be provided can be installed. However, the farthest socket must not • The distribution box should have one 50 mm (2 inch)
from the main telephone room, to each telephone closet exceed 90 m from the cabinet
• It should be installed at a height of 120 cm above the conduit to the rooftop of the villa, from the cabinet or
and extended up to the roof telephone room
finished floor level from the telephone entry duct location, in order to provide
• Two power sockets are required, inside the indoor access to cables from the antenna
• The risers to each floor must be symmetrical and equipment cabinet, for powering the optical network unit
• The conduits leading from the floor distribution box
vertically in line with the main telecom room. and battery rectifier
However, where the main telecom room, floor telephone towards flat, should not be less than 25 mm diameter Installation of in-building fibre drop cables
closet and roof telecom rooms are to be located one • The cabinet distribution box location should not be
• Adequate safe working space is to be provided around High-rise buildings
below the other in vertical line, a continuous cable trays/ adjacent to any electrical distribution or bus bars
each location
conduits must be provided with pull boxes/access panels at
every turning point and at interval of 15 meters each, up to • The cabinet distribution box should be installed at a The building owner should install a minimum of 2 core fibre
• The distribution boxes on a floor, should not be linked to
the main telecom room. Right angle or sharp bends are to height of 120 cm above the finished floor level drop cables, from the main telecom room ODF location
or serve any other floor of the building
be avoided to the indoor cabinet location of each flat/premises.
• The distribution boxes location should never be near any • All internal conduits should be of a diameter not less Termination of these fibres should be by Etisalat on the
• If a building consists of more than one tower, all the electrical junction box or bus bars. Adequate safe working than 25 mm (1 inch) to extend the structured cables from ONU and ODF. Installer to leave an extra length of 3 m of
above specified requirements are required in each tower space should be provided in front of each box ONU to SCS socket locations at each room cable on either end for terminations. The cables must be
suitably labeled

5 6
accordance with route may also be route may also be route may also be route may also be
Etisalat advise provisioned provisioned provisioned provisioned

Design guide www.etisalat.ae Apartment Indoor 12U (H) x 600 mm 12U (H) x 600 mm 42U (H) x 800 mm 42U (H) x 800 mm 42U (H) x 800 mm 42U (H) x 800 mm 42U (H) x 800 mm 12U (H) x 600 mm
Distribution Cabinet (W) X 515 mm (D) (W) X 515 mm (D) (W) X 800 mm (D) (W) X 800 mm (D) (W) X 800 mm (D) (W) X 800 mm (D) (W) X 800 mm (D) (W) X 515 mm (D)
std 19“ Rack flush mounted on flush mounted on Stand alone type Stand alone type Stand alone type Stand alone type Stand alone type flush mounted
wall wall, per villa 19” equipment 19” equipment 19” equipment 19” equipment 19” equipment on wall
Cabinet Cabinet Cabinet Cabinet Cabinet

Single villas Etisalat telecom requirements


In the case of single villas, Etisalat will extend and The Table No. 1 below, details the different requirements
terminate the FO cable, directly in the ONU. for the various types of buildings and types.
In all other cases, the 2 core drop cables should be
extended to the ODF location in the telecom room,
Bldg Single villa Complex of Bldgs (G+5) Bldg floors Bldg floors (G+10) Shopping malls Palaces & Group of shops
by the owner. Types villas or (G+6) to (G+10) and more hospitals & sheds
Building area or or
upto 3000 m2 Bldg of 100 over 100 tenants
tenants or
Bldg Single villa Complex of Bldgs (G+5) Bldg floors Bldg floors (G+10) Shopping malls Palaces & Group of shops or Bldg area more than
Types villas or (G+6) to (G+10) and more hospitals & sheds Telecom Bldg area 7000 m2
Building area or or Requirements upto 7000 m2
upto 3000 m2 Bldg of 100 over 100 tenants
tenants or
or Bldg area more than
Telecom Floor Size: Per single villa. Size: Size: Size: Size: Size: Size:
Bldg area 7000 m2
Requirements Distribution Box One 30x30 x15 cm Size: One One 30x30x15 cm One 30x30x15 cm One 30x30x15 cm One 30x30x15 cm One 30x30x15 cm One 30x30x15 cm box
upto 7000 m2
box recessed inside 30x30x15 cm box boxes flush to wall box flush to wall box flush to wall box flush to wall box flush to wall flush to wall
the wall for each recessed inside the
floor. wall for each floor. Location: Location: Location: Location: Location: Location:
Entry Box Size: Size: Size: Size: Size: Size: Size: Size: To be provided in To be provided in To be provided in To be provided in To be provided in To be provided in each
60x60x80 cm. JRC-4 Joint Box JRC 12 Joint Box JRC 12 Joint Box JRC 12 Joint Box JRC 12 Joint Box JRC 12 Joint Box 60x60x80 cm with Location: Location: each floor Telecom each floor Telecom each floor Telecom each floor Telecom each floor Telecom floor Telecom Closet
(Etisalat standard) (Etisalat standard) (Etisalat standard) (Etisalat standard) (Etisalat standard) (Etisalat standard) Grade A cover Convenient location Convenient location Closet Closet Closet Closet Closet
with 1 meter free with one meter free
Location: Location: Location: Location: Location: Location: Location: Position: wall space around wall space around
Within the Depends upon the Within the property, Within the property, Within the property, Depending on the Depending on the Within land plot and at a height and at a height
compound and at layout near plot line. near plot line. near plot line. layout layout where lead-in between 40-120 cm between 40-120 cm
Max 1 m from Additional Boxes at Additional Boxes at Additional Boxes at branching to other above finished above finished
compound wall line all turning points all turning points all turning points blocks end floor level. floor level.
of lead-in of lead-in of lead-in at turning points

Main No requirements Size: Size: Size: Size: Size: Size: Size:


Telecom Room 2x3x3 (LxWxH) 2x3x3 (LxWxH) 3x3x3 (LxWxH) 3x4x3 (LxWxH) 3x4x3 (LxWxH) 3x4x3 (LxWxH) 2x3x3 (LxWxH) meters
Entry Pipes/Duct A single (2”) inch A single (4”) inch 2x (4”) inch 2 x (4”) inch 2 x (4”) inch 2 x (4”) inch 2 x (4”) inch A single x (4”) inch meters for villas meters meters meters meters meters
pipes/duct towards pipes/ducts to be pipes/ducts towards pipes/ducts towards pipes/ducts towards pipes/ducts towards pipes/ducts towards pipes/ducts to be more than Location:
the villa & single x extended one meter the building and the building and the building and the building and the building and extended one meter 10 numbers Location: Location: Location: Location: Location: In the ground floor
(2”) inch outside the plot line four x (4”) inch four x (4”) inch four x (4”) inch four x (4”) inch four x (4”) inch outside the plot line In the ground floor In the ground floor In the ground floor In the ground floor In the ground floor common area.
pipes/ducts to be towards Etisalat pipes/ducts towards pipes/ducts towards pipes/ducts towards pipes/ducts towards pipes/ducts towards towards Etisalat common area. common area. common area. common area. common area.
extended outside Network. Internal the Etisalat Network the Etisalat Network the Etisalat Network the Etisalat Network the Etisalat Network Network.
the plotline towards Distribution within
Etisalat Network plot to be in A diversity entry A diversity entry A diversity entry A diversity entry
accordance with route may also be route may also be route may also be route may also be Floor No requirements No requirements Size: Size: Size: Size: Size: Size:
Etisalat advise provisioned provisioned provisioned provisioned Telecom Closet Closet (LxWxD) Closet (LxWxD) Closet (LxWxD) Closet (LxWxD) Closet (LxWxD) Closet (LxWxD)
100x60x60 cm 100x60x60 cm 100x60x60 cm 100x60x60 cm 100x60x60 cm 100x60x60 cm

Location: Location: Location: Location: Location: Location:


In common area In common areas In common areas In common area In common areas In common areas
Apartment Indoor 12U (H) x 600 mm 12U (H) x 600 mm 42U (H) x 800 mm 42U (H) x 800 mm 42U (H) x 800 mm 42U (H) x 800 mm 42U (H) x 800 mm 12U (H) x 600 mm
Distribution Cabinet (W) X 515 mm (D) (W) X 515 mm (D) (W) X 800 mm (D) (W) X 800 mm (D) (W) X 800 mm (D) (W) X 800 mm (D) (W) X 800 mm (D) (W) X 515 mm (D)
std 19“ Rack flush mounted on flush mounted on Stand alone type Stand alone type Stand alone type Stand alone type Stand alone type flush mounted
wall wall, per villa 19” equipment 19” equipment 19” equipment 19” equipment 19” equipment on wall Riser Cable Trays No requirements No requirements 20x5 cm 20x5 cm 20x5 cm 20x5 cm 20x5 cm No requirements
Cabinet Cabinet Cabinet Cabinet Cabinet cable trays cable trays cable trays cable trays cable trays

Table 1 Table 1 (Continued)

7 8

Bldg Single villa Complex of Bldgs (G+5) Bldg floors Bldg floors (G+10) Shopping malls Palaces & Group of shops
Types villas or (G+6) to (G+10) and more hospitals & sheds
Design guide www.etisalat.ae

Structured Cabling System (SCS) • Completed SCS should be subject to acceptance by Accessories to a flat/apartment distribution box inside the flat or
Etisalat. However, the design and performance of the SCS apartment. No looping of cables from outlet to outlet is
To deliver the services from the ONU, a SCS System on star system should be the responsibility of the installer/owner All accessory plates should be dual or quad white PVC permitted
topology is required. The minimum requirement is standard plated. The use of any special faceplate, which may be
CAT 6 cable with RJ45 connectivity. A SCS design being • Any upgrading required in the in–building facility, specific to any other manufacturer’s product range, such as • The horizontal cabling is to be provided to single, dual,
project specific, a discussion, with complete details is telecommunication cables, due to either enhanced demand, brass finish, etc. should be reviewed. triple and quad outlets throughout
recommended with system designers and Etisalat. change in building status or damage should be provided by
building owner The choice of outlets distribution, location and type, either • The length of cable between the farthest
However, the following are the general minimum it is single, dual, or quad, the optimum requirements in telecommunications outlet and the distribution box should
requirements of structured cabling systems, for provision • The supply and termination of UTP cables on patch each area, ultimate number of outlets in every locations, not exceed 90 m (295 ft.)
of service. panel or IDC modules and sockets locations should be the flexibility and maximum usage, should be the responsibility
responsibility of the installers/owners of consultants. • A minimum of two telecommunications outlets should be
Cabling & termination provided for each individual work area. The outlets may be
• Etisalat would supply and install, main ODFs, mini ODFs Horizontal subsystem (UTP Cables) located with one or more faceplates in the work area
Telecommunication cabling and optical network units (ONUs). All jumperings and
patchings in the ODFs, patch panels in ONUs would be the All horizontal cables should be based on the Category 6 Horizontal pathways
• The cables used for these wiring must comply with responsibility of Etisalat. Building owners/contractors or performance compliant.
other technicians are totally prohibited to carry out these • Horizontal pathways (conduits, sleeves, cable trays,
minimum CAT 6 standards
functions All conductors in each cable should be connected to a etc.) are used for taking the cables from the floor
• The planned SCS cable should meet the designed service single RJ45 socket at the work area outlets and patch telecommunications room to the telecommunications
requirements within the particular flat level and should Telecommunication socket panel. Each cable should be terminated to maintain the outlets in the same floor
have built-in flexibility, to meet growing needs of the twists in each pair within 5 mm of the termination. Proper
tenants All outlets should be Category 6 performance, outlets • A variety of methods are available and the choice of
strain relief should be provided for the cable at the outlets
mounted in shutters, typically in dual, triple or quad selection of method should depend on the purpose of the
and patch panel, avoiding strain on the conductors
• All SCS cables are to be properly labeled and terminated, formation in a single or double gang white faceplate. floor area to be served (i.e. general office spaces, apartment
in the RJ45 sockets and in-patch panel or in CAT 6 All RJ45 outlets should be fitted with spring loaded sliding dwellings, etc.)
Colour coding for the termination should be as per the
compliant IDC modules by the owners shutters to prevent the ingress of dirt and dust.
following table.
Conduits
• Building owner is responsible for replacement of in- • Provision for at least one dual socket for
Pair Tip Ring
building cables and other fixtures, if these become faulty telecommunication services should be made in every room • The use of conduits as a horizontal raceway system
including kitchen. Conduit with not less than 25 mm 1 White Blue should only be considered when the outlet locations are
• Cable diagrams must be submitted to Etisalat for should be connected between the socket locations 2 White Orange permanent, the device densities are low and flexibility is
approval at the design stage and as-built is required on 3 White Green not required
completion • Every socket must be connected with a minimum of four
pair SCS Cat 6 cable, following star topology. In case of 4 White Brown
• The minimum size of a conduit pipe used as a
• Cables and other accessories required for block wiring hotel buildings, the provision of telecommunication socket horizontal pathway from the distribution box to the
may be purchased from any reputable source provided that should also be extended to the bathrooms telecommunications outlet should be 25 mm (1 inch)
the material meets standards Horizontal cabling
• Telecommunication sockets, cables and associated • For the conduits, the inside bending radius should always
• The name and contact telephone numbers of the SCS facilities within the various rooms and premises are to be • The physical topology of the horizontal cabling should
be at least 10 times the internal diameter
installer, should be labeled at appropriate location provided by the building owner be configured as a star with each outlet connected directly

9 10
Design guide www.etisalat.ae

• Minimum of one nylon draw wire must be installed in a Cable tray size Truncking size No. of UTP • Vertical cable management Voice services can be fed from the services patch panel
conduit (mm) (mm) cables directly to the user outlet using standard 1 pair patch
• Bonded to a local earth point cords.
50x50 50x50 30
• Pull boxes should be located such that they are readily
accessible at all times. Pull boxes to be spaced at a 75x50 50x75 45 B) Wall-mounted type cabinets Labeling
maximum of 15 m apart to minimize cable stress during 100x50 50x100 60
installation and to provide serviceability in the future 100x50 75x75 67 These are recommended for flats, villas, shops, etc. and Label elements
should be provided flush with wall, at a common location
150x 50 75x100 90 where all SCS cables, patch panels/IDC modules, fibres, All floor outlets, patch frames and horizontal cables should
• Conduits must be free from sharp edges, to prevent cable
damage during and subsequent to pulling 200x50 100x100 120 power and ONU equipment are proposed to be installed. be labeled. A typewritten standard labeling system is
300x 50 150x150 180 The cabinet should be exclusive for Etisalat use and no recommended. The labeling scheme shall be agreed on with
• Conduits protruding through a floor should be 450x50 - 360 access to others should be allowed. the clients’ telecom team.
terminated; a minimum of 50 mm from the floor to prevent 900x50 - 540
water or other liquids from flowing into the conduits • 12U – 22U 600 mm wide x 515 mm deep 19” wiring/ Horizontal cable labels
equipment cabinet
Where a FO cable block wiring is considered, a very careful Label all horizontal cables at both ends using a self-
Maximum number of UTP cables inside a conduit, consideration must be taken, while designing the system. • Glass front door with provision for air circulation laminating, wrap around label.
recommended for the installation of a Structured Cabling The owner should be responsible for the design, supply and
System is as follows: maintenance of all related items. • Vertical cable management User outlet labels
Conduit trade Internal dia No. of Cat Indoor equipment cabinet 19” • Bonded to a local earth point Each RJ45 user outlet should be labeled with a unique
size (mm) 6 cables
identifier, typically using the agreed scheme.
1” 25.40 7 Depending upon the termination and patch panel We recommend that the proposed locations of the cabinets
1
1 /4” 34.04 13 requirement, and to accommodate other active and passive have sufficient space around the cabinets to allow access Under-floor systems
equipment, a cabinet with standard 19” rack is required, to installation and maintenance and should be located in
11/2” 39.88 18 generally complying with the following:- central locations, where all the terminations of the SCS • For general office spaces, an under-floor raceway system
2” 51.31 30 should be used for maximum flexibility
cables on patch panels/IDC modules and fibre termination
A) Free standing types and ONUs, power socket and battery back up, should be
installed. • In multi-channel layouts, separate raceways must be
Cable capacities in trays conduits Recommended for high-rise buildings, shopping malls, used for telecommunications and electrical power to
hospitals, airports, large commercial establishments, etc. Patching reduce electromagnetic interference. The dividers for
When the internal cable trays, risers and ladders, etc. are separation of compartments in the raceway should be
designed, supplied and installed by others, the maximum The cabinets should be: The design of patch frame layouts is critical to create a bonded to ground
number of UTP cables, recommended to be installed on • 42U 800 mm wide x 800 mm deep 19” equipment cabinet high level of manageability within a compact cabinet,
a tray as shown; however this need to be reduced in the while maintaining effective operations when used by the Main elements of under-floor raceway
case of bends and crossovers. The formula applied is that • Glass front door with provision for air circulation systems
customer.
for every 25 mm x 25 mm cross section, 8 cables can be
accommodated. No truncking or cable tray should be more • Steel rear door Distribution raceway
We recommend all horizontal UTP cabling should be
than 75% full on installation. terminated in a 12 or 24 port patch panel, placed inside
• Jacking feet • Distribution raceway provides a pathway for the cables
the wall or floor cabinet. Alternatively, Cat 6 compliant IDC
modules can also be used. from the feeder raceway to the work areas. The minimum
• Horizontal cable management

11 12
Design guide www.etisalat.ae

size of the distribution raceway should be 30 mm height x Etisalat should be consulted in the initial design stage to Typical building environment Room size
60 mm width of cross-sectional area. The same size must decide on the requirements if the building is designed for Minimum separation distance from power source <480V
be used for every (multi-channel) layout office use. • For up to 100 extensions, the minimum floor space
Condition <2kVA 2-5kVA 5kVA
required is 2 m x 3 m
Feeder raceway Protection from Unshielded power lines 130 mm 300 mm 600 mm
electromagnetic interference or electrical equipment • For up to 400 extensions, the floor space required
• Feeder raceway provides a pathway for the cables from is 4 m x 4 m
in proximity to open or
the distribution box in the floor telecommunications room The following requirements apply to UTP cabling,
to the distribution raceways. The minimum size of the non-metal pathways
as pathways and spaces used to carry or house • For large systems Etisalat must be consulted at the
feeder raceway should be 40 mm height x 200 mm width telecommunications cabling. Unshielded power 65 mm 155 mm 300 mm planning stage
of cross-sectional area. The same size must be used for lines or electrical
every (multi-channel) layout • The proximity of cabling to electrical facilities and • The room should have a minimum height of 3 m, be air-
equipment in proximity
equipment that generate high levels of electromagnetic conditioned, clean, and dry and free from dust
• The feeder raceways starting point in the floor to grounded metal
interference (EMI) should be taken into account for
telecommunications room must be adjacent to the metallic cabling conduit pathway Room general requirements
distribution box. The Feeder raceway should end at the last Power lines enclosed 50 mm 155 mm 300 mm
distribution raceway it is serving • Sources of EMI include: power cables, photocopy • The room should be far away from high voltage plant.
in a grounded metal
equipment, electric motors, transformers, fluorescent Other services/utility ducts should not run through this
Access unit conduit (or equivalent
lighting, arc welders and induction heaters, etc. room and it should not be directly under a toilet or
• The access unit provides access at the point of shielding in proximity bathroom
intersection of the feeder and the distribution raceways To avoid EMI, the telecommunications pathways, spaces to grounded metal
and metallic cables should be installed with the following conduit pathway) • The room should provide ready access to Etisalat
Cable trays clearances: personnel and equipment but must be secured from
Transformers and 1M 1M 1M
unauthorized entry
• Cable trays are mostly used for floors with raised tiles or electric motors
41.2 m (4 ft) from large motors or transformers
floorings
40.3 m (1 ft) from conduit and cables used for electrical Fluorescent lighting 300 mm 300 mm 300 mm • The room must be properly protected from the risk of
power distribution flooding if provided in the basement or lower levels
• As a general guideline, cable trays that intersect must be
412 cm (5 in) from fluorescent lighting
provided with a transitional bend radius of 150 mm in all Private Branch Exchange (PBX) • In multi-PBX user building, each PBX to have
directions
• Pathways and metallic cables should cross perpendicular its own room
In case where communication systems with more than 64
• Exposed sheet metal edges must be provided with to fluorescent lighting and electrical power cables or
extensions (i.e. PBX system) are required, special facilities
bushings or other means of protection such that cables will conduits • Raised flooring should be provided when required
need to be provided as follows:
not be damaged during or after installation. Since cable depending on the PBX type
trays are usually metallic, all sharp edges, burrs and screw Separation distance from power source
Equipment room
tips that may come into contact with cabling should be During the design stages, separation of power and the • For large PBX installations, air-conditioned battery room
removed Structured Cabling Systems (SCS) must be considered. adjacent to the equipment room will be required.
A room for the exclusive use of Etisalat is needed for the
Unshielded data cables should not be installed near sources Etisalat will supply details at the design stage. The battery
telephone equipment. The room should be accessed by
• The minimum access space between the sub-floor and of electromagnetism. The guidelines are listed on the room should be provided with an exhaust fan. Conduit
the underground cables and the distribution to the floor
the underside of the floor tile should be minimum next page. or tray is required between the equipment room and the
cables. The main telecom room can be considered for PABX
150 mm (6 in) battery room
installation in case of commercial single owner building.

13 14
Design guide www.etisalat.ae

• Direct sunlight should not fall in the PBX room. Curtains/ 4) Where deviations/comments/amendments are advised
screens are to be provided for the windows if any on the design, drawings must be corrected and
re-submitted for approval.
• Power conduit and telecom cable conduit must be
separate 5) One set of approved ‘As-Built’ drawings must be
submitted along with the building completion certificate,
Electrical requirements which will be certified by Etisalat.

• A minimum of two 13 amp 240 v A/C main outlets (via) 6) Etisalat’s responsibility is limited to provision and
UPS system should be provided. The actual mains power installation of ODFs, termination of fibres, patching/
requirements will depend on the size and type of the PBX jumpering works and Optical Network Units (ONUs).

• The room should be provided with an earth not more 7) The owners are responsible for supply and installation
than 5 ohms of all internal FO cables from ODF (main telecom room) List of annexures
to ONU (customer premises) locations, provision of wall
• Anti-static flooring should be provided, including the mounted or stand alone cabinets to accommodate ONU,
battery room power, patch panels, etc. and complete structured cabling
system.
• The rooms must be provided with an emergency light, Annexure I type of entry box
a smoke detector and a fire alarm 8) The indoor drop 2 F fiber cables, should be from a (JRC 4 & JRC 12)
popular brand and make, conforming to ITU standard G 652
PABX can be installed in the main telecom room in the case single mode fiber standards.
of a single owner.
9) On completion of the requirements, any comments Annexure II typical examples
Important note and snags advised by Etisalat building inspector, must be
attended to by the contractor or owner of the building
1) This design guide explains in general, all Etisalat soon, to avoid delays in the issuance of the building
requirements that will facilitate the provision of completion certificate.
telecommunication services to new buildings, yet the
requirements indicated in the ‘NOC’ (No Objection
Certificate) should be fully complied.

2) Architects/consultants/designers must liaise with
Etisalat at the design stage and obtain Etisalat approval on
the final design drawings.

3) Minimum two sets of telephone design drawings must


be submitted for study and approval, before tendering.

15 16
Design guide www.etisalat.ae

1 ‫الملحق رقم‬
Annexure 1

17 18
Design guide www.etisalat.ae

1 ‫الملحق رقم‬ 2 ‫الملحق رقم‬


Annexure 1 Annexure 2
Typical telecom requirement in villas

19 20
Design guide www.etisalat.ae

2 ‫الملحق رقم‬
Annexure 2
Typical telecom requirement in multi-storey building

TYPICAL TELECOM REQUIREMENT IN VILLAS

21 22