Вы находитесь на странице: 1из 80

Thomas & Betts is proud to present a new and improved catalogue for its line of Hazlux industrial lighting

products. From the Atlantic to the Pacific coasts, these fixtures are certified for use in some of the most demanding industrial environments Canada has to offer and are built to keep performing even under the most adverse conditions.

Whether you are a specifying engineer, electrical distributor or an electrical contractor, this catalogue has been designed to simplify the lighting fixture selection process. For each model of lighting fixture, you will find the following information: sample fixture assembly catalogue numbering system accessories dimensional drawings To match fixtures with the right applications, at the top of each right-hand page you will find a reference listing all applicable compliances and certifications. Hazlux lighting fixtures explosion proof lighting for hazardous and adverse environments.

C.E.C. Code Changes In 1998, the Canadian Electrical Code (C.E.C.) adopted the International Electrotechnical Commission's (IEC) Three Zone Area Classification System for Class I hazardous locations. The Zone System is an alternate classification for Class I hazardous locations and was adopted to promote harmonization with international standards. The Division System for Class I hazardous locations continues to be used for existing facilities and is expected to remain in use at least for the next few editions of the C.E.C. For this reason, this catalogue's certification information for Class I hazardous locations includes both the pre-1998 Division System and the new I.E.C. Zone System. The following pages provide an overview of C.E.C. hazardous location classifications.

Classes The Canadian Electrical Code (C.E.C.), Part I, Section 18 - Hazardous Locations identifies three classes of hazardous locations: Class I - Gas and Vapour Environments Class II - Dust Environments Class III - Fibers and Flyings Environments

The 1998 revisions to the C.E.C. affect only Class I - Gas and Vapour Environments.

Hazardous location is defined by the C.E.C. as premises, buildings or parts thereof in which there exists the hazard of fire or explosion due to highly flammable gases and/or flammable, volatile liquid mixtures that are manufactured, used or stored in other than the original containers. This definition can also be extended to include combustible dust and easily ignitable fibers that are likely to be present in sufficient quantities to produce an explosive mixture.

Class I Gas and Vapour Environments Locations which are deemed hazardous due to the presence of gases or vapours that are present in the air in sufficient quantity to produce explosive or ignitable mixtures. Locations identified as Class I require that enclosures and connectors be explosion proof. Class I hazardous locations are further subdivided into : Divisions (pre-1998 version of the C.E.C.), or Zones (I.E.C. Classification - 1998 C.E.C.) The Division System may still be used for the maintenance and repair of existing facilities. All new construction must use the I.E.C. Zone Classification.

Divisions Division 1 A Class I location where the hazardous atmosphere is expected to be present during normal operations on a continuous, intermittent or periodic basis. Division 2 A Class I location in which volatile flammable liquids or gases are handled, processed or used but in which they would normally be confined within closed containers or closed systems from which they can escape only in the event of an accidental rupture or breakdown of the containers or systems.

Area ClassificationDivisions vs. Zones Continuous Hazard Zone 0 Division 1 Zones Zone 0 Class I locations in which explosive gas atmospheres are present continuously or are present for long periods. Zone 1 Class I locations in which: i. explosive gas atmospheres are likely to occur in normal operation; or ii. explosive gas atmospheres may exist frequently because of repair or maintenance operations or because of leakage; or iii. the location is adjacent to a Class I, Zone 0 location, from which explosive gas atmospheres could be communicated. Zone 2 Class I locations in which: iv. explosive gas atmospheres are not likely to occur in normal operation and if they do occur they will exist for a short time only; or v. flammable volatile liquids, flammable gases or vapours are handled, processed, or used, but in which liquids, gases or vapours are normally confined within closed containers or closed systems from which they can escape only as a result of accidental rupture or breakdown of the containers or systems or the abnormal operation of the equipment by which the liquids or gases are handled, processed or used; or vi. explosive gas atmospheres are normally prevented by adequate ventilation but which may occur as a result of failure or abnormal operation of the ventilation system; or vii. the location is adjacent to a Class I, Zone 1 location from which explosive gas atmospheres could be communicated, unless such communication is prevented by adequate positive-pressure ventilation from a source of clean air, and effective safeguards against ventilation failure are provided. Intermittent Hazard Zone 1 Hazard under Abnormal Conditions Zone 2 Division 2

Gas Group Designations Two systems of groupings for gases are included in the 1998 C.E.C: the pre-1998 Division Gas Groups consisting of Groups A, B, C and D; and the IEC System consisting of Groups IIA, IIB and IIC. Both systems are accepted by the C.E.C.

Comparison of Hazardous Location Gas Group Designations From Most Restrictive to Least Restrictive

Typical Gas Hazard Acetylene Hydrogen Ethylene Propane

Division Gas Groups A B C D

1998 CEC and IEC Gas Groups IIC IIB IIA

Division Gas Groups Group A: acetylene Group B: butadiene, ethylene oxide, hydrogen, manufactured gases containing more than 30% hydrogen (by volume), propylene oxide Group C: acetaldehyde, cyclopropane, diethyl, ether, thylene, unsymmetrical dimethyl hydrazine (UDMH 1, 1-dimethyl hydrazine) Group D: acetone, acrylonitrile, alcohol, ammonia, benzene, benzine, benzol, butane, 1-butanol, 2-butanol, butyl acetate, isobutyl acetate, ethane, ethanol, ethyl acetate, ethylene dichloride, gasoline, heptanes, hexanes, isoprene, methane, methanol, 3-methyl-1-butanol, methyl ethyl ketone, 2-methyl-1-propanol, 2-methyl-2-propanol, naphtha, natural gas, petroleum naphtha, octanes, pentanes, 1-pentanol, propane, 1-propanol, 2-propanol, propylene, styrene, toluene, vinyl acetate, vinyl chloride, xylenes I.E.C. Zone Gas Groups Group IIC: acetylene, butadiene, propylene oxide, carbon disulphide, hydrogen or other gases or vapour of equivalent hazard Group IIB: cyclopropane, diethyl ether, ethylene, ethylene oxide, hydrogen sulfide, unsymmetrical dimethyl hydrazine (UDMH) or other gases or vapour of equivalent hazard Group IIA: acetaldehyde, acetone, acrylonitrile, alcohol, ammonia, benzine, benzol, butane, ethylene dichloride, gasoline, hexane, isoprene, lacquer solvent vapours, naptha, natural gas, propane, propylene, styrene, vinyl acetate, vinyl chloride, xylenes or other gases or vapour of equivalent hazard

Class IIDust Environments Locations which are deemed hazardous due to the presence of combustible or electrical conducting dusts. Class II locations normally require that enclosures and connectors be dust tight. Class IIIFibers and Flyings Environments Locations which are deemed hazardous due to the presence of easily ignitable fibers or flyings, but in which such fibers or flyings are not likely to be in suspension in the air in sufficient quantities to produce ignitable mixtures. Class III locations normally require that enclosures and connectors be constructed to minimize the entry of fibers or flyings. Class II and IIIDivisions Class II and Class III locations are further subdivided as follows: Division 1 Where the hazardous atmosphere is expected to be present during normal operations on a continuous, intermittent or periodic basis. Division 2 Where volatile, flammable liquids or gases are handled, processed or used, but in which they would normally be confined within closed containers or closed systems from which they can escape only in the event of an accidental rupture or breakdown of the containers or systems. Class II and IIIGas Group Designations The Canadian Electrical Code (C.E.C.), Part 1 Section 18 - Hazardous Locations defines various groups which have been established for the purpose of testing and approval. Group E Comprising atmospheres containing metal dust including aluminum, magnesium, and their commercial alloys, and other metals of similarly hazardous characteristics. Group F Comprising atmospheres containing carbon black, coal or coke dust. Group G Comprising atmospheres containing flour, starch or grain dust, and other dusts of similarly hazardous characteristics.

Hazlux Fixture Label Sample

Ignition Temperatures and Group Classifications for Flammable Gases and Vapors
AUTOIGNITION TEMPERATURE MATERIAL ACETALDEHYDE ACETIC ACID ACETIC ANHYDRIDE ACETONE ACETONE CYANOHYDRIN ACETONITRILE ACETYLENE ACROLEIN (INHIBITED) ACRYLIC ACID ACRYLONITRILE ALLYL ALCOHOL ALLYL CHLORIDE ALPHA-LIMONENE 2-AMINOETHANOL AMMONIA n-AMYL ACETATE ANILINE BENZENE BENZYL CHLORIDE 1.3-BUTADIENE BUTANE BUTYL ALCOHOL SEC-BUTYL ALCOHOL n-BUTYL ACETATE n-BUTYL ACRYLATE (INHIBITED) BUTYLAMINE BUTYLENE n-BUTYRALDEHYDE n-BUTYRIC ACID CARBON DISULFIDE CARBON MONOXIDE CHLOROBENZENE 2-CHLOROETHANOL 2-(CHLOROMETHYL)oxirane CRESOL CROTONALDEHYDE CUMENE CYCLOHEXANE CYCLOHEXANOL CYCLOHEXANONE CYCLOHEXENE CYCLOPROPANE p-CYMENE n-DECANOL GROUP DEGREES F C D D D D D A B(C) D D C D D D D D D D D B(D) D D D D D D D C D * C D D C D C D D D D D D D D 347 867 600 869 1270 975 581 455 820 898 713 905 458 770 928 680 1139 928 1085 788 550 650 761 790 559 594 725 425 830 194 1128 1099 797 772 1038-1110 450 795 473 572 473 471 938 817 550 DEGREES C 175 464 316 465 688 524 305 285 438 481 378 485 237 410 498 360 615 498 585 420 288 343 405 421 293 312 385 218 443 90 609 593 425 411 559-599 232 424 245 300 245 244 503 436 288

*Carbon Disulfide has characteristics which require safeguards beyond those required for any of the above groups.

AUTOIGNITION TEMPERATURE MATERIAL DECENE DI-ISOBUTYL KETONE DI-ISOBUTYLENE DI-N-PROPYLAMINE DIACETONE ALCOHOL o-DICHLOROBENZENE 1.1-DICHLOROETHANE 1.2-DICHLOROETHYLENE DICYCLOPENTADIENE DIETHYL BENZENE DIETHYL ETHER DIETHYLAMINE DIETHYLENE GLYCOL MONOBUTYL ETHER DIETHYLENE GLYCOL MONOMETHYL ETHER n-n-DIMETHYL ANILINE DIMETHYL FORMAMIDE DIMETHYL SULFATE DIMETHYLAMINE 1,1-DIMETHYLHYDRAZINE 1,4-DIOXANE DODECENE DU-ISOPROPYLAMINE ETHANE ETHANOL ETHYL ACETATE ETHYL ACETATE (INHIBITED) ETHYL BENZENE ETHYL CHLORIDE ETHYL FORMATE 2-ETHYLHEXAN-1-OL 2-ETHYL HEXYL ACRYLATE ETHYL MERCAPTAN ETHYLAMINE ETHYLENE ETHYLENE DICHLORIDE ETHYLENE GLYCOL MONOBUTYL ETHER ETHYLENE GLYCOL MONOBUTYL ETHER ACETATE ETHYLENE GLYCOL MONOETHYL ETHER ETHYLENE GLYCOL MONOETHYL ETHER ACETATE ETHYLENE GLYCOL MONOMETHYL ETHER ETHYLENE OXIDE ETHYLENEDIAMINE ETHYLENIMINES 2-ETHYLEHEXALDEHYDE GROUP DEGREES F D D D C D D D D C D C C C C C D D C C C D C D D D D D D D D D C D C D C C C C D B(C) D C C 455 745 736 570 1118 1198 820 860 937 743-842 320 594 442 465 700 833 370 752 480 356 491 600 882 685 800 702 810 966 851 448 485 572 725 842 775 460 645 455 715 545 804 725 608 375 DEGREES C 235 396 391 299 603 647 438 460 503 395-450 160 312 228 241 371 455 188 400 249 180 255 316 472 363 427 372 432 519 455 231 252 300 385 450 413 238 340 235 379 285 429 385 320 191

Ignition Temperatures and Group Classifications for Flammable Gases and Vapors (Contd)
AUTOIGNITION TEMPERATURE MATERIAL FORMALDEHYDE (GAS) FORMIC ACID (90%) FUEL OILS FURAN-2-YLMETHANOL FURFURAL GASOLINE HEPTANE HEPTENE HEXAN-2-ONE HEXANE HEXENES HYDRAZINE HYDROGEN HYDROGEN CYANIDE HYDROGEN SULFIDE ISO-BUTYL ACETATE ISO-OCTYL ALDEHYDE ISOAMYL ACETATE ISOAMYL ALCOHOL ISOBUTYL ACRYLATE ISOBUTYRALDEHYDE ISOPHORONE ISOPRENE ISOPRPOPENYLBENZENE ISOPROPYL ACETATE ISOPROPYL ETHER ISOPROPYLAMINE KEROSENE LIQUIFIED PETROLEUM GAS MESITYL OXIDE METHANE METHANOL METHOXYMETHANE METHYL ACETATE METHYL ACRYLATE METHYL ETHYL KETONE METHYL FORMAL METHYL FORMATE METHYL ISOBUTYL KETONE METHYL ISOCYANATE METHYL METHACRYLATE METHYL N-AMYL KETONE 2-METHYLPROPAN-1-OL 2-METHYL-2-PROPANOL GROUP DEGREES F B D D C C D D D D D D C B C C D C D D D C D D D D D D D D D D D C D D D C D D D D D D D 795 813 410-765 915 600 536-880 399 500 795 437 473 74-518 968 1000 500 790 387 680 662 800 385 860 428 1066 860 830 756 410 761-842 652 999 725 662 850 875 759 460 840 840 994 792 740 780 892 DEGREES C 429 434 210-407 490 316 280-471 204 260 424 225 245 23-270 520 538 260 421 197 360 350 427 196 460 220 574 460 443 402 210 405-450 344 537 385 350 454 468 404 238 449 449 534 422 393 416 478

10

AUTOIGNITION TEMPERATURE MATERIAL METHYLAMINE METHYLCYCLOHEXANE METHYLCYCLOHEXANOL MONOISOPROPANOLAMINE MONOMETHYL ANILINE MONOMETHYL HYDRAZINE MORPHOLINE NAPHTHA (COAL TAR) NAPHTHA (PETROLEUM) NITROBENZENE NITROETHANE NITROMETHANE 2-NITROPROPANE 1-NITROPROPANE NONANE OCTANE OCTENE PENTANE 1-PENTANOL 2-PENTANONE 1-PENTENE PROPANE PROPAN-2-OL 1-PROPANOL PROPIONALDEHYDE PROPRIONIC ACID PROPRIONIC ANHYDRIDE n-PROPYL ACETATE n-PROPYL ETHER PROPYL NITRATE PROPYLENE PROPYLENE DICHLORIDE PROPYLENE OXIDE PYRIDINE STYRENE TETRAHYDROFURAN TETRAHYDRONAPTHALENE TOLUENE TURPENTINE VALERALDEHYDE VINYL ACETATE VINYL CHLORIDE VINYL TOLUENE VINYLIDENE CHLORIDE XYLENES GROUP DEGREES F D D D D C C C D D D C C C C D D D D D D D D D D C D D D C B D D B(C) D D C D D D C D D D D D 806 482 565 705 900 382 590 531 550 900 778 785 802 789 401 403 446 470 572 846 527 842 750 775 405 870 545 842 419 347 851 1035 840 900 914 610 725 896 488 432 756 882 921 1058 867-984 DEGREES C 430 250 296 374 482 194 310 277 288 482 414 418 428 421 205 206 230 243 300 452 275 450 399 413 207 466 285 450 215 175 455 537 449 482 490 321 385 480 253 222 402 472 494 570 464-529

11

Hazlux Industrial Lighting Fixtures Designed, Tested and Certified for use in Hazardous Locations and Adverse Environments

NEW LABOUR-SAVING FEATURES FOR HAZLUX 3 FIXTURES Induction Lighting Long life for reduced maintenance Hazlux 3 induction lighting provides a 60,000+ hour lamp life, drastically reducing the cost of expensive maintenance of industrial lighting in hazardous locations. For complete details, see pages 32-33.

Hazvertor Adapter Ring Replace other brand fixtures without removing the top hat The Hazvertor adapter ring gives you the freedom to replace Crouse-Hinds Champ series lighting fixtures (VMV, DMV or LMV types) with Hazlux 3 lighting fixtures without removing the CrouseHinds top hat from the conduit system, eliminating the need to replace conduit and wiring.

Save time and increase efficiency. The Hazvertor can be ordered as a separate item or as part of a Hazlux 3 fixture assembly. Look for the HV1 mounting style options and convert to increased efficiency, wider suitability for hazardous locations, improved light distribution and cooler T-numbers.

12

Enclosed and gasketed fixtures designed and certified for use in wet locations and a wide range of industrial environments where flammable gases and vapours may be present Nameplate displays third party certification for all electrical ratings and hazardous location ratings as required by the Canadian Electrical Code, OSHA regulations and CSA Each component CSA-listed and identified with required markings Cast, copper-free aluminum construction for high strength, light weight and corrosion resistance Standard finish is baked, electro-deposited, pure epoxy powder for maximum corrosion protection All exposed hardware is corrosion-resistant stainless steel Simple hinge arrangement permits hands-free wiring Seizure-resistant threads make installation and maintenance easy Heat-sunk internal components result in cooler operation for extended ballast life and broader range of hazardous locations Electromechanical connect block for quick, safe fixture removal for bench relamping and/or maintenance High strength mechanical mountings to withstand ice or strong wind loads Heat tempered glass for greater strength and thermal shock resistance Instant restart available to prevent unnecessary downtime due to minor power outages (HPS only) Auxiliary quartz lamp available to provide temporary lighting after power outages on HPS or MH circuits

13

From an offshore oil rig in the Atlantic Ocean to the oil sands of Northern Alberta, theres a Hazlux lighting fixture to stand up to virtually every hazardous location in Canada. Here is a list of some of the places youll find Hazlux fixtures: Chemical manufacturing and processing plants Oil refineries Oil drilling rigs Offshore platforms Pipeline pumping stations Pulp and paper plants Aluminum and copper smelting Steel mills and foundries Mining operations Grain handling facilities Flour, sugar and starch processing Food processing plants Paint and rubber manufacturing facilities Marine and coastal facilities Shipyards and shipbuilding plants Power generation plants Waste treatment facilities Paint, chemical and plastic mixing/storage areas Bulk truck terminals Solvent/cleaning areas Hazlux lighting fixtures are also built to withstand the harsh environmental conditions that exist in real working environments.

HOSE-DOWN AND WET LOCATIONS Certified for wet locations - NEMA 4X, IP66 (indoor and outdoor); UL1598 (marine) and CSA Listed. Superior gasketing system - both tank and globe gasketing systems withstand hose-down pressures. Uninterrupted globe thread - assures positive seal. Baked-on dry epoxy coating - not paint, but 100% dry solids. Globes, refractors, and finish designed to withstand thermal shock during hose-down. HIGH AMBIENT TEMPERATURE AREAS All standard fixtures are tested and listed for at least 40C ambient - even under heavy dust blanket and no air flow. Exclusive heat sink design - results in a cool operating fixture, extended ballast/lamp life, and lower maintenance costs. Unmatched selection of high ambient temperature rated fixtures - contact factory for fixtures certified for 55C and 65C applications. Steam spray and thermal shock resistant. CORROSION AND ABRASION

VIBRATION, SEISMIC SHOCK, VANDALISM Vibration tested by CSA. Vibration-resistant hardware throughout fixture. Screw retainers on guard assure retention even if screws are not completely tightened. Designed for use with safety chains - without fixture modification. Vibration resistant globe thread and sealing system. Optional refractors, high-strength tempered glass, and Tuff-Skin globes for protection from vandalism. DUST BLANKET Tested and listed by CSA. Thermal performance is at 40C ambient. Optional thermal performance to 55C and 65C ambient available. Consult factory. Cone pendant mount available (45 sloped sides) for areas where dust or other residue buildup is a problem. Exclusive heat sink design - results in a cool operating fixture, extended ballast/lamp life and lower maintenance costs. MARINE DUTY OPTION UL1598 Marine listed. This feature is supplied as standard on most HAZLUX 3 fixtures. Consult Thomas & Betts Sales Office for details. Designed for abuse - hose-down, arctic, hurricane, vibration and shock, high temperature, corrosion and other environmental conditions typical of adverse marine locations. Exclusive combination of marine and hazardous location approvals on the same fixture line.

Typical Applications
ICE AND ARCTIC CONDITIONS

Baked-on dry epoxy coating - not paint, but 100% dry solids. Stainless steel external hardware. Sand-blast resistant finish. Superior silicone gasketing system on both tank and globe - other gasketing systems available for special corrosive applications, such as phosphates. Aluminum components contain less than 0.4% copper maximum corrosion resistance. Special HAZ-COTE corrosion fighter finish available for extremely corrosive areas, consult Thomas & Betts Sales Office for details.

Gasketing system and finish allow for expansion and contraction through wide temperature variations. Metal halide ballasts start at -29C. High pressure sodium ballasts start down to -51C. Consult Thomas & Betts Sales Office for details. High-strength mechanical mountings withstand extra ice loading. Tempered glassware available for extra thermal shock safety margin.

WIND Wind-tunnel tested at McDonnell Douglas Corporation at air flow speeds in excess of 320 km/h. Guard specially designed to secure reflector during high wind loading. All fasteners are stainless steel. High strength mechanical mountings withstand strong wind loads.

15

16

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M1 medium base and Hazlux 1 mogul base polymeric lighting fixtures are certified for use in Class I, Zone 2 and Division 2 locations and indoor or outdoor locations where lighting fixtures are exposed to corrosion accelerators such as dust, rain, hose-directed water and ice formation.

Fiberglass-reinforced polyester housing and mounting covers provide excellent strength, durability and corrosion resistance Impact-resistant and corrosion-resistant polycarbonate guards protect glass globes and refractors Guards have keyhole slots for ease of attachment to grounded, stainless steel guard screws Thermal shock-resistant globes and refractor globes provide superior protection for HID lamps and effective options for light distribution

M1/1

Polymeric reflectors are reinforced fiberglass that resist corrosion, UV rays and weathering and are bright white for maximum reflectance

17

Hazlux M1 Fixture Assembly Sample

Mounting Style

VPA2 Rigid Pendant Cone

VPC2 Ceiling Mount

Ballast Tank

Fluorescent Tank

H.I.D. Tank

Globe or Refractor

VGT15

VGT15

VGL15R5

Guard

VGU15P Polymeric Guard

VGU15P Polymeric Guard

Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

18

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M1 Catalogue Numbering System


Metal Halide or High Pressure Sodium

PD S M 05 P 12 O GGL C2 E F C
1 2 3 4 5 6 7 8 9 10 11 12

Fluorescent Only

PD F B 13 P 12 O GGL C2 E C
1 2 3 4 5 6 7 8 9 10 11

1 2

Fixture Series PD = Hazlux M1 Fixture Lamp Type H = Metal Halide HP = Metal Halide Pulse Start (100W) S = High Pressure Sodium F = Fluorescent Lampholder M = Medium Base Lampholder B = Bi Pin Type (Fluorescent) Lamp Wattage 09 = 9 watt (Fluorescent) 13 = 13 watt (Fluorescent) 18 = 18 watt (Fluorescent) 26 = 26 watt (Fluorescent) 03 = 35 watt 05 = 50 watt 07 = 70 watt 10 = 100 watt Ballast Circuit P = Reactor Type, Fluorescent H = High Reactance Voltage 12 = 120 Volt 27 = 277 Volt (Fluorescent) Tank O = Standard Housing

Optical Assembly Options G = Glass Globe GGL = Glass Globe with Polymeric Guard TG = Tempered Globe Only TGL = Tempered Globe and Polymeric Guard R1 = Glass Refractor (IES Type I) without Guard R3 = Glass Refractor (IES Type III) without Guard R5 = Glass Refractor (IES Type V) without Guard R1P = Glass Refractor (IES Type I) with Polymeric Guard R3P = Glass Refractor (IES Type III) with Polymeric Guard R5P = Glass Refractor (IES Type V) with Polymeric Guard CBDL = Closed Bottom Reflector with Polycarbonate Lens Mounting Style A2 = 3/4 in. Cone Pendant C2 = 3/4 in. Ceiling, 1 Hub C22 = 3/4 in. Ceiling, 2 Hubs Hazpak Options U = Hazpak no lamp E = Hazpak C/W Clear Lamp Special Options * F = Fuse Kit (For HID Only) CSA Certification C = CSA Nameplate

10

11 12

* not CSA approved in hazardous locations

19

Hazlux M1 Accessories
OUTLET BOXES Designed for all Hazlux
MOUNTING STYLE
Rigid Pendant Cone

M1 Ballasts Housings.

EXIT SIGN
CATALOGUE NO. STD. PKG. COLOUR

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

VPA2

3/4''

VRE22

Red

Ceiling Mount

VPC2 VPC22
(FEED THROUGH)

3/4''

GLOBES OR REFRACTORS
CATALOGUE NO. DESCRIPTION

VGT15 VGL15P VGL15R1 VGL15R3 VGL15R5

Heat-Resistant Prismatic Glass Polycarbonate Plastic Globe IES Type I Refractor Globe IES Type III Refractor Globe IES Type V Refractor Globe

VR22CBDL

Low Bay Refractor with Plastic Lens

GUARDS
CATALOGUE NO. DESCRIPTION

VGU15P

Polymeric For Use With Glass Globes or Refractors

REFLECTORS
CATALOGUE NO. DESCRIPTION

VR15P

Standard Dome Fiber Glass Reinforced Polyester

VRA15P

30 Angle Reflector Fiber Glass Reinforced Polyester

20

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M1 Dimensions
CONE PENDANT MOUNT
8 /8"
(219 mm)
5

CEILING MOUNT
9 5/8"
(244 mm) Dia. B.C.

8 5/8"
(219 mm)

7 /8"
(200 mm)

6 7/8"
(174 mm)

6 11/16" 9 3/4"
(248 mm) (200 mm)

6 11/16" 9 3/4"
(200 mm) (248 mm)

157/8"
(403 mm)

157/8"
(403 mm)

WITH ANGLED REFLECTOR

WITH ANGLED REFLECTOR

8 5/8"
(219 mm)

9 5/8"
(244 mm) Dia. B.C.

8 5/8"
(219 mm)

7 /"
(200 mm)

7 8

6 7/8"
(174 mm)

4 7/8"
(124 mm)

6 11/16"
(170 mm)

4 7/8"
(124 mm)

6 11/16"
(170 mm)

15"
(381 mm)

15"
(381 mm)

WITH DOME REFLECTOR

WITH DOME REFLECTOR


8 5/8"

8 5/8"
(219 mm)

(219 mm)

7 7/8"
(200 mm)

7 7/8"
(200 mm)

6 11/16" 9 3/4"
(200 mm)

6 1/2"
(165 mm)

(248 mm)

157/8"
(403 mm)

NO REFLECTOR

NO REFLECTOR

21

Hazlux 1 Fixture Assembly Sample

Mounting Style

VNP2 Rigid Pendant

VNC2 Ceiling Mount

VNB2 Wall Mount

VNS5 Angle Stanchion

VNL5 Straight Stanchion

Ballast Tank

H.I.D. Tank

Globe or Refractor

VGT31S

VGL31R5

Guard

VGU31RP Polymeric Guard

VGU31RP Polymeric Guard

Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

22

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D

UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 1 Catalogue Numbering System

P S O 07 H 12 O - R5P - C2 - E - D C
1 2 3 4 5 6 7 8 9 10 11 12

Fixture Series P = Hazlux 1 Fixture Lamp Type H = Metal Halide S = High Pressure Sodium (up to 150W) Starter Options O = Standard Fixture J = Auto-Shutoff (HPS Only) R = Instant Re-Strike (HPS Only) Lamp Wattage 05 = 50 watt 07 = 70 watt 10 = 100 watt 15 = 150 watt 17 = 175 watt (MH Only) Ballast Circuit C = Constant Wattage Auto Transformer (CWA) H = High Reactance P = Reactor Type Voltage 09 = 12 = 34 = 48 = 120/277/347, 60Hz 120 Volt 347 Volt 480 Volt

Optical Assembly Options TG = Tempered Globe Only TGP = Tempered Glass Globe and Epoxy Coated Guard R1 = Glass Refractor (IES Type I) without Guard R3 = Glass Refractor (IES Type III) without Guard R5 = Glass Refractor (IES Type V) without Guard R1P = Glass Refractor (IES Type I) with Polymeric Guard R3P = Glass Refractor (IES Type III) with Polymeric Guard R5P = Glass Refractor (IES Type V) with Polymeric Guard Mounting Style P2 = 3/4 in. Pendant B2 = 3/4 in. Wall C2 = 3/4 in. Ceiling S5 = 1-1/2 in. Angle Stanchion L5 = 1-1/2 in. Straight Stanchion Hazpak E = D = U = Options Hazpak with Clear Lamp Hazpak with Diffused Coated Lamp Hazpak without Lamp

10

11

Reflector Options D = Dome Reflector A = Angle Reflector CSA Certification C = CSA Nameplate

12

Tank O = Standard Housing

23

Hazlux 1 Accessories
OUTLET BOXES Designed for all Hazlux1 Ballasts Housings.
MOUNTING STYLE
Rigid Pendant

OUTLET BOXES Designed for all Hazlux1 Ballasts Housings.


MOUNTING STYLE
Angle Stanchion

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

VNP2

3/4''

VNS5

1-1/2''

Ceiling Mount

VNC2
Wall Mount

3/4''

Straight Stanchion

VNL5 VNB2 3/4'' 1

1-1/2''

GLOBES
CATALOGUE NO. DESCRIPTION

VGT31S VGT31STS

Heat Resistant Glass (7-3/4'' dia.) 250 Watt Max. Heat Resistant Glass (7-3/4'' dia.) Coated with Tuff-Skin, 250 Watt Max.

GUARDS
CATALOGUE NO. DESCRIPTION

VGU31RP

For use with Threaded Glass Globes and Refractors (7-3/4'' dia.) Polymeric

REFLECTORS
CATALOGUE NO. DESCRIPTION

VR31P VR31P

Standard Dome Fiber Glass, Reinforced Polyester For use with 7-3/4'' dia. Globes 30 Angle Reflector Fiberglass, Reinforced Polyester For use with 7-3/4'' dia. Globes

REFRACTORS
CATALOGUE NO. DESCRIPTION

VGL31R1 VGL31R3 VGL31R5

IES Type I Light Distribution (Long and Narrow) Threaded Glass Globe Refractor 734'' dia. IES Type III Light Distribution (Asymmetric) Threaded Glass Globe Refractor 734'' dia. IES Type V Light Distribution (Symmetric) Threaded Glass Globe Refractor 734'' dia.

24

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D

UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 1 Dimensions

11 3/4"
(298 mm)

11"
(279 mm)

11 3/4"
(298 mm)

11 3/4"
(298 mm)

9"
(229 mm)

10"
(254 mm)

9" 9"
(229 mm) (229 mm)

8"
(203 mm)

8" 8"
(203 mm) (203 mm)

PENDANT MOUNT WITH REFRACTOR AND GUARD

WALL ARM MOUNT WITH GLOBE AND GUARD

CEILING MOUNT WITH GLOBE AND GUARD

4 7/8" 16 7/8"
(429 mm) (124 mm)

16 7/8"
(429 mm)

9 7/8"
(251 mm)

WALL MOUNT FLANGE TEMPLATE

9 7/8"
(251 mm)

4 5/8"
(117 mm)

3 3/4"
(95 mm)

18 1/8"
(460 mm)

18 1/8"
(460 mm)

13 5/8"
(346 mm)

12 15/16"
(332 mm)

CEILING MOUNT TOP VIEW

11 3/4"
(298 mm) DIA.

20 3/4"
(527 mm)

STRAIGHT STANCHION MOUNT

ANGLE STANCHION MOUNT

1"
(25 mm)

11 3/4"
(298 mm)

11 3/4"
(298 mm)

1"
(25 mm)

9"
(229 mm)

9"
(229 mm)

5 1/8"
(130 mm)

8"
(203 mm)

15 1/4"
(387 mm)

20"
(508 mm)

20 1/4"
(514 mm)

DOME REFLECTOR WITH REFRACTOR AND GUARD

ANGLE REFLECTOR WITH GLOBE AND GUARD

25

26

Class I Zone 2, Groups IIC, IIB, IIA, Exn R II T3 (Restricted Breathing*) Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M3 medium base and Hazlux 3 HID mogul base fixtures are enclosed and gasketed for use in Class I, Zone 2 and Division 2 hazardous locations as well as Class II dust environments. These fixtures are also certified for use in restricted breathing areas as well as indoor or outdoor locations where lighting fixtures are exposed to corrosion accelerators such as dust, rain, hose-directed water and ice formation.
Hazlux M3 Compact, low profile design highly cost efficient for areas where space or fixture weight is restricted Easy to install electromechanical connection block, hinged covers, self-aligning refractors, prewired ballast Unipak option provides factory assembled, pre-lamped fixtures proven installation savings of 1/2 hour per fixture Light sources HID metal halide and high pressure sodium; fluorescent and incandescent Superior thermal design for use in elevated temperature environments also provides cooler operating performance at normal ambient temperatures Self-aligning high efficiency prismatic glass refractors; fluted glass globes and computer-designed fiberglass-reinforced polyester reflectors provide superior photometrics Hazlux 3 NEW - induction lighting lamp option as well as high pressure sodium and metal halide Three ballast housing sizes standard, refractor globe and large install easily on any of seven standard mounting styles Simple hinge arrangement allows for hands-free wiring Tri-tap ballast provides ratings of 120/277/347 volts All ballasts are high power factor (90% minimum) incorporating non-PCB capacitors Ballast housings available for High Pressure Sodium and Metal Halide lamps in wattages from 35 to 400 watts Standard ballasts are rated starting at 29C with lower operating temperature ballasts available on request Unique gasketing action ensures NEMA 4X and IP66 Threaded globe refractors, in IES types I, III and V. Programmed cutting of ballast tank threads ensures accurate orientation for types I and III light patterns. Globe type refractors are positive sealing, ensuring NEMA 4X and IP66 conformance Threaded globe refractors do not require tools for relamping Types I and III threaded globe refractors self alignment feature assures future maintenance will be quick and will not require costly readjustment of light pattern

*Hazlux 3 only. With appropriate fittings installed

27

Hazlux M3 Fixture Assembly Sample

Mounting Style

VMP2 Rigid Pendant

VMC2 Ceiling Mount

VMB2 Wall Mount

VMS4 Angle Stanchion

VML4 Straight Stanchion

Ballast Tank

Housing Incandescent

Housing Fluorescent

Housing H.I.D.

Globe or Refractor

VGT15

VGL15R5

VGT15

VGT15

VGL15R5

Guard

VGU15P Polymeric Guard

VGU15 Polymeric Guard

VGU15P Polymeric Guard

VGU15 Polymeric Guard

VGU15P Polymeric Guard

VGU15 Polymeric Guard

Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

28

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M3 Catalogue Numbering System


HID

D
1

S
2

M
3

07
4

P
5

120 - R5P - C2 T
6 7 8 9

E
10

C
11

Incandescent Only

D
1

I
2

M
3

10
4

O
5

120 - GGL - C2
6 7 8

T
9

C
10

Fluorescent Only

D
1 1 2

F
2

B
3

18
4

O
5

120 - GGL - C2 T
6 7 8 9 7

D
10

C
11

Fixture Series D = Hazlux M3 Fixture Lamp Type S = High Pressure Sodium H = Metal Halide F = Fluorescent I = Incandescent Lampholder M = Medium Base Lampholder B = Bi Pin Type (Fluorescent)

Optical Assembly Options (Contd) TGL = Tempered Globe and Polymeric Guard TGC = Tempered Globe and Cast Guard R1 = Type I (Long and Narrow) Glass Refractor R3 = Type III (Assymetric) Glass Refractor R5 = Type V (Symetric) Glass Refractor R1P = Type I Refractor and Polymeric Guard R3P = Type III Refractor and Polymeric Guard R5P = Type V Refractor and Polymeric Guard R5A = 8 in. Glass Refractor (Type V) CBDL = Closed Bottom Refractor with Polycarbonate Lens Mounting Style P2 = 3/4 in. Rigid Pendant P3 = 1 in. Rigid Pendant B2 = 3/4 in. Wall B3 = 1 in. Wall C2 = 3/4 in. Ceiling C3 = 1 in. Ceiling L4 = 1-1/4 in. Straight Stanchion L5 = 1-1/2 in. Straight Stanchion S4 = 1-1/4 in. Angle Stanchion S5 = 1-1/2 in. Angle Stanchion

8 4
Lamp Wattage 09 = 9 watt 13 = 13 watt 18 = 18 watt 26 = 26 watt 03 = 35 watt 05 07 75 10 15 = = = = = 50 watt 70 watt 75 watt 100 watt 150 watt (HPS Only)

6 7

Ballast Circuit C = Constant Wattage Autotransformer (CWA) D = Fluorescent 24 VDC P = Reactor Type (HPS & Flood) O = Incandescent Voltage 120 = 120 Volt Optical Assembly Options G = Standard Globe Only GGL = Standard Globe and Polymeric Guard GG = Standard Globe and Cast Guard TG = Tempered Globe Only

Special Options T = HAZ-COTE Custom Corrosion Coating on All Aluminum Parts (Consult Factory) Hazpak D = E = U = Options Hazpak with Diffused Coated lamp Hazpak with Clear lamp Hazpak with No Lamp

10

11

CSA Certification C = CSA Nameplate

29

Hazlux M3 Accessories
OUTLET BOXES
MOUNTING STYLE
Rigid Pendant

OUTLET BOXES
CAT. NO. CONDUIT HUB SIZE MOUNTING STYLE
Wall Mount

CAT. NO.

CONDUIT HUB SIZE

VMP2 VMP3
Ceiling Mount

3/4'' 1''
Stanchion Mount

VMB2 VMB3

3/4'' 1''

VMC2 VMC3

3/4'' 1''

VMS4 VMS5 25
Stanchion Mount

1-1/4'' 1-1/2''

EXIT SIGN
CATALOGUE NO. STD. PKG. COLOUR

VML4 VML5 90

1-1/4'' 1-1/2''

VRE22

Red

GLOBES OR REFRACTORS
CATALOGUE NO. DESCRIPTION

VGT15 VGL15P VGL15R1 VGL15R3 VGL15R5 VRF22C5A VR22CBDL

Heat-Resistant Prismatic Glass Polycarbonate Plastic Globe IES Type I Refractor Globe IES Type III Refractor Globe IES Type V Refractor Globe 8 IES Type V Reflector Low Bay Refractor with Plastic Lens

GUARDS
CATALOGUE NO. DESCRIPTION

VGU15 VGU15P

Cast Aluminum - for use with glass globes or refractors Polymeric - for use with glass globes or refractors

REFLECTORS
CATALOGUE NO. DESCRIPTION

VR15P VRA15P

Standard Dome Fiber Glass Reinforced Polyester 30 Angle Reflector Fiberglass Reinforced Polyester

30

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M3 Dimensions
RIGID PENDANT
8 5/8"
(219 mm)

WALL MOUNT
15 3/8"
(279 mm)

1 3/8"
(35 mm)

11"
(279 mm)

4 3/16"
(106 mm)

4 9/16"
(116 mm)

6 1/2"
(165 mm)

2"
(51 mm)

4 3/16"
(106 mm)

CEILING MOUNT
9 5/8"
(244 mm)

9 3/4"
(248 mm)

6 11/16"
(200 mm)

1 3/4"
(44 mm)

157/8"
(403 mm)

4 3/16"
(106 mm)

6 1/2"
(165 mm)

90 STANCHION MOUNT

25 STANCHION MOUNT
14 9/16"
(370 mm)

14 9/16"
(370 mm)

10 1/4"
(260 mm)

10 1/4"
(260 mm)

2 7/8"
(73 mm)

9 1/4"
(235 mm)

9 1/4"
(235 mm)

4 3/16"
(106 mm)

2 7/8"
(73 mm)

4 3/16"
(106 mm)

6 1/2"
(165 mm)

6 1/2"
(165 mm)

15 7/8"
(403 mm)

15 7/8"
(403 mm)

31

Hazlux 3 Induction Lighting Fixture


Now you can use the longest-life lamp available on the market. In the typical process industry plant, reliable lighting is often required in hazardous, hard-to-reach places. Lamp replacement not only places employees at risk, but often requires the rental of expensive equipment such as scissor lifts. With the introduction of Hazlux Induction Lighting Fixtures for hazardous areas (Class 1, Zone 2, Groups IIA, IIB, IIC, Exn R II T3 (restricted breathing*), Div. 2 Groups A, B, C, D) and non-hazardous areas, you can benefit from the longest lamp life available on the market. Hazlux 3 HID lights are equipped with Philips QL Induction lamps for the longest lamp life ever.
60,000+ hour lamp life Reduced maintenance/re-lamp operations Instant On-Instant Restrike at ambient temperature of 20C Automatic switch-off in case of failure Warm white light Exceptional energy efficiency -40C to 40C ambient operating range Retrofits into existing Hazlux 3 applications Acceptable for use with infrared remote control equipment operating at 36kHz RFI-approved for environments up to 1000 MHz (FCC part 18 reference luminaire)

s ix time Over s of a fe li the tal nal Me traditio Lamp! Halide

Heres how you save maintenance costs with Hazlux Induction Lighting:
Eliminates the need for expensive HID options such as Quartz Auxiliary Lamps or Instant Restrike. Reduces risks to installers performing maintenance in hard-to-reach places. Reduces number of times necessary to de-energize entire circuit of lights for maintenance in hazardous locations. Increases efficiency by decreasing machine shutdown time. Lowers cost of expensive rental of scissor lifts or bucket trucks.

Hazlux Induction Lighting reduces the cost of expensive maintenance of industrial lighting in hazardous locations.

*With appropriate fittings installed.

Induction

Class I Zone 2, Groups IIC, IIB, IIA, Exn R II T3 (Restricted Breathing) Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Induction Lighting Fixture Catalogue Numbering System

D I 0 16 E 12 L - R5G - P2 T E
1 2 3 4 5 6 7 8 9 10 11

Fixture Series D = Hazlux 3 HID Fixture Lamp Type I = Induction Lighting

Starter Circuit/Quartz Options 0 = Standard Fixture

Lamp Wattage 16 = 165 Watt Induction System Ballast Circuit E = Electronic Ballast (Induction Fixture) Voltage 12 = 120V 60 Hz Tank L = Large Tank

Mounting Style A2 = 3/4 in. Cone Top Pendant A3 = 1 in. Cone Top Pendant Mount B2 = 3/4 in. Wall Mount B3 = 1" Wall Mount C2 = 3/4 in. Ceiling Mount C3 = 1" Ceiling Mount F2 = 3/4 in. Flexible Pendant F3 = 1" Flexible Pendant HV1 = Hazvertor Ring Class I, Div 2, Zone 2 L4 = 1-1/4 in. Straight Stanchion L5 = 1-1/2 in. Straight Stanchion P2 = 3/4 in. Rigid Pendant P3 = 1 in. Rigid Pendant S4 = 1-1/4 in. 25 Degree Stanchion S5 = 1-1/2 in. 25 Degree Stanchion

Special Options T = Haz-Cote Custom Corrosion Coating (Consult Factory) Hazpak Options E = Hazpak with Induction Lamp

10

Optics and Guards R5G = Type V Refractor with Wire Guard R5 = Type V Refractor

With appropriate fittings installed

33

TM

Quick Pole Assembly


Quick, Safe & Effective

SAFETY FIRST
CSA certied product One person operation No ladders or lifts required Simplied maintenance Hot dipped galvanized steel and aluminum nishes Frees up catwalks and walkways during maintenance Epoxy coated nishes available

34

Q U I C K P O L E A S S E M B LY
Features & Benets
Certications
Suitable for 180km/h winds* as per AASHTO LTS-4 2001 Steel pole treads are treated and protected to prevent galvanic reaction as per AASHTO LTS-4 2001 CSA certied products

Construction
Sphere shaped, quick knuckle features round edges, preventing injuries and contaminent build-up of components The quick release mechanism is activated using one hand and one pull pin The quick pole assembly blocks at a 90 angle when the pull pin reaches the stopper All quick knuckle hardware is made of stainless steel All mounting brackets hardware are hot dip galvanized

* Please contact your All-StructTM sales representatives for xture types and mounting height limitations.

Quick Pole Assembly


Operates in any kind of weather Overall length is 10 (3 m) Pole trade size is 1-1/2 treaded NPT Top pole section is 70 (1.78 m) long Lower pole section is 50 (1.27 m) long

Quick Knuckle Assembly


Rotates 180 (90 left and right) around knuckles center axis allowing freedom of installation and easy adjustment Easy one man operation. After center bolt is loosen, use the pull pin to lock and unlock the assembly

Brackets
Universal mounting for 2 to 3 angle iron railings Quick mounting brackets can be installed inside or outside the guardrails Quick knuckle assembly should be mounted above hand rail allowing the pole sections to rotate before nal positionning

35

Q U I C K P O L E A S S E M B LY
Galvanized Standard Kit
Description
Overall height of 10 (3 m) 1-1/2 NPT treads at both ends Installed with two rail mounting brackets
1. Rotating Quick Knuckle Assembly 2. Angle Iron Mounting Brackets allowing the pole section to rotate before nal positionning 1

Retrot Kit
Description
Overall maximum and predetermined height of 10 (3 m) once assembled Can be adapted to existing pole Upgrades existing assembly with quick and easy maintenance features See instruction sheets provided with product for installation details
1

1. Rotating Quick Knuckle Assembly 2. Tapered Adaptor, ts over Standard 1-1/4 or 1-1/2 NPT Pipe

2 2

Cat. No.:

Cat. No.:

Q-P-5-10

RQ-P-5-10

All All-Struct products are assembled or manufactured in Thomas & Betts ISO 9001 certied facilities and are designed to CSA and/or AASHTO standards. WARRANTY: Thomas & Betts warrants its products to be free from defects in materials and workmanship for a period of one year from the invoice date under normal use and service. All goods found to be defective within this period after verication by Thomas & Betts shall be replaced or repaired by Thomas & Betts free of charge. The warranty excludes fatigue failure or similar phenomena resulting from vibration or resonance associated with improper installation, overloading, misuse, abuse or neglect. Further, labor required to remove and/or reinstall original or replacement products shall be the responsibility of the customer.

In addition, this warranty does not cover alterations, modications, or additions unless the change is acknowledged and accepted, in advance in writing, by Thomas & Betts. E.P.A.: The allowable effective projected areas listed for this product are intended to be for hazardous location luminaires. For other type of applications (cameras, banner arms, wiring, signs or any other type of product), please contact your All-StructTM sales representative for assistance in selecting the correct structure or product.

36

Q U I C K P O L E A S S E M B LY
Universal Bracket Kit

Cat. No.:

Cat. No.:

AMB-QP-BKT

RMB-QP-BKT Description
Quick bolt-on installation, no welding or drilling Can be attached to angle iron guardrails up to 3 Can be installed on tubular structures less than 2 O.D. Allows the pole sections to rotate before nal positionning

37

Hazlux 3, Standard Housing, Fixture Assembly Sample

Mounting Style

HV1 Hazvertor

VP2 or VF2 Pendant

VA2 Rigid Pendant Cone

VC2 Ceiling Mount

VB2-OLD Wall Mount

VS5 Angle Stanchion

VL5 Straight Stanchion

Ballast Tank

Standard Tank

Globe or Refractor

VGT22

VRF22C5

VR22CBDL

Guard

VGU22P Polymeric Guard

VGU22 Cast Guard

VGR48

Reflector

VR22P Standard Dome

VRA22P 30 Angle Reflector

38

Standard Housing

Class I Zone 2, Groups IIC, IIB, IIA, Exn R II T3 (Restricted Breathing) Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 3 Standard Housing Catalogue Numbering System

D S 0 15 H 09 0 - TGL - P2 E1 F C
1 2 3 4 5 6 7 8 9 11 12 13

1 2

Fixture Series D = Hazlux 3 Fixture Lamp Type S = High Pressure Sodium H = Metal Halide Starter Circuit/Quartz Options 0 = Standard Fixture P = Pulse Start (MH Only) Q = Quartz Auxiliary Option (Not Hazardous Rated) R = Instant Restart (HPS Only) J = Auto Shutoff Starter (HPS Only) Lamp Wattage 05 = 50 Watts 07 = 70 Watts 10 = 100 Watts 15 = 150 Watts 17 = 175 Watts 20 = 200 Watts 25 = 250 Watts (MH Only)

Mounting Style A2 = 3/4 in. Cone Top Pendant A3 = 1 in. Cone Top Pendant B2 = 34 in. Wall Mount B3 = 1 in. Wall Mount C2 = 34 in. Ceiling Mount C3 = 1 in. Ceiling Mount F2 = 34 in. Flexible Pendant F3 = 1 in. Flexible Pendant HV1 = Hazvertor Ring - Class I, Div. 2, Zone 2 L4 = 1-14 in. Straight Stanchion L5 = 1-12 in. Straight Stanchion P2 = 34 in. Rigid Pendant P3 = 1 in. Rigid Pendant S4 = 1-14 in. 25 Angle Stanchion S5 = 1-12 in. 25 Angle Stanchion Special Options T = Haz-Cote Custom Corrosion Coating (Consult Factory) Hazpak E = E1 = E2 = D = D1 = D2 = U = Options Hazpak with Clear Lamp Hazpak Clear Lamp, Dome Reflector Hazpak, Clear Lamp, Angle Reflector Hazpak with Dual Arc Lamp Hazpak, Dual Arc Lamp, Dome Reflector Hazpak Dual Arc Lamp, Angle Reflector Hazpak No Lamp

10

Ballast Circuit H = High Reactance C = Constant Wattage Autotransformer (CWA) (AII ballasts high power factor.) I = Constant Wattage Isolated (CWI) Voltage/Frequency 09 = 120/277/347V, 60Hz 12 = 120V, 60Hz 24 = 240V, 60Hz 27 = 277V, 60Hz 28 = 208V, 60Hz 34 = 347V, 60Hz 225 = 220V, 50Hz 245 = 240V, 50Hz Ballast Housing Style 0 = Standard Housing (150W HPS, 250W MH) Optical Assembly Options TG = Thermal Shock Resistant Globe TGC = TG With Cast Aluminium Guard TGL = TG with Polymeric Guard SG = Tuffskin Coated Globe SGL = SG with Polymeric Guard R2 = 12 in. Glass Refractor, Type II R5 = 12 in. Glass Refractor, Type V R2G = R2 with Wire Guard R5G = R5 with Wire Guard CBDL = Closed Bottom Refractor with Polycarbonate Lens

11

12

Fusing Options * F = Single Fuse Block with Fuse FF = Double Fuse Block with Fuse CSA Certification C = CSA Nameplate

13

7 8

*Not CSA certified in hazardous locations With appropriate fittings installed

39

Hazlux 3, Standard Housing Accessories


OUTLET BOXES
MOUNTING STYLE
Rigid Pendant

OUTLET BOXES
CAT. NO. CONDUIT HUB SIZE MOUNTING STYLE
Wall Mount

CAT. NO.

CONDUIT HUB SIZE

VP2 VP3
Cone Pendant

3/4'' 1''
Angle Stanchion

VB2 VB3

3/4'' 1''

VA2 VA3
Flexible Pendant

3/4'' 1''
Straight Stanchion

VS4 VS5 VL4 VL5


Adaptor Ring

3/4'' 1'' 3/4'' 1'' N.A.

VF2 VF3
Ceiling Mount

3/4'' 1'' 3/4'' 1''

VC2 VC3

HV1

GLOBES OR REFRACTORS
CATALOGUE NO. DESCRIPTION

VGT22 VGT22TS VRF22C2 VRF22C5 VR22CBDL

5-1/2 dia. Heat Resistant Globe (250W max.) 5-1/2 dia. Heat Resistant Globe (250W max.) coated with Tuff-Skin 12 dia. IES Type II Refractor, 5-1/2 thread 12 dia. IES Type V Refractor, 5-1/2 thread Low Bay Refractor with Plastic Lens

REFLECTORS OR EXIT SIGN


CATALOGUE NO. DESCRIPTION

VR22P VRA22P VRE22

Standard Dome, Fiberglass Reinforced Polyester 30 Angle Reflector, Fiberglass Reinforced Polyester Three Sided Exit Sign

GUARDS
CATALOGUE NO. DESCRIPTION

VGU22P VGU22 VGR48

Polymeric Guard for VGT22 Series Globe Cast Guard for VGT22 Series Globe Steel Wire Guard for All VRF Series 12 Refractors

40

Standard Housing

Class I Zone 2, Groups IIC, IIB, IIA, Exn R II T3 (Restricted Breathing*) Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 3, Standard Housing Dimensions


STANDARD BALLAST HOUSING WITH GLOBE AND GUARD
133/8"
(340 mm)

147/8" 133/8"
(340 mm) (378 mm)

133/8"
(340 mm)

133/8"
(340 mm)

1811/32" 133/4"
(349 mm)

133/4"
(349 mm)

(466 mm)

141/2"
(368 mm)

163/4"
(425 mm)

RIGID PENDANT

FLEXIBLE PENDANT

CONE PENDANT

CEILING MOUNT

WALL MOUNT

161/8"
(410 mm)

153/4"
(400 mm)

133/8"
(340 mm)

153/16"
(386 mm)

153/16"
(386 mm)

143/4"
(375 mm)

25 STANCHION MOUNT

STRAIGHT STANCHION

HAZVERTOR RING

STANDARD BALLAST HOUSING WITH 12 REFRACTOR AND GUARD


133/8"
(340 mm)

147/8" 133/8"
(340 mm) (378 mm)

133/8"
(340 mm)

133/8"
(340 mm)

1611/16"
(424 mm)

1611/16"
(424 mm)

211/4"
(540 mm)

175/16"
(440 mm)

199/16"
(497 mm)

RIGID PENDANT

FLEXIBLE PENDANT

CONE PENDANT

CEILING MOUNT

WALL MOUNT

161/8"
(206 mm)

153/4"
(400 mm)

133/8"
(340 mm)

181/8"
(460 mm)

181/8"
(460 mm)

179/16"
(446 mm)

25 STANCHION MOUNT

STRAIGHT STANCHION

HAZVERTOR RING

*With appropriate fittings installed

41

Hazlux 3, Refr. Globe Housing, Fixture Assembly Sample

Mounting Style

HV1 Hazvertor

VP2 or VF2 Pendant

VA2 Rigid Pendant Cone

VC2 Ceiling Mount

VB2-OLD Wall Mount

VS5 Angle Stanchion

VL5 Straight Stanchion

Ballast Tank

R Tank

Globe or Refractor

VGT31S

VGL31R5

VR31CB

Guard

VGU31RP Polymeric Guard

VGU31R Cast Guard

VGR64 Wire Guard

Reflector

VR31P Standard Dome

VRA31P 30 Angle Reflector

42

Refractor Globe Housing

Class I Zone 2, Groups IIC, IIB, IIA, Exn R II T3 (Restricted Breathing) Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 3 Refractor Globe Housing Cat. Numbering System

D
1

S
2

0
3

15
4

H
5

09
6

R - R5 - P2
7 8 9

E1
11

F
12

C
13

1 2

Fixture Series D = Hazlux 3 Fixture Lamp Type S = High Pressure Sodium H = Metal Halide Starter Circuit/Quartz Options 0 = Standard Fixture P = Pulse Start (MH Only) Q = Quartz Auxiliary Option (Not Hazardous Rated) R = Instant Restart (HPS Only) J = Auto Shutoff Starter (HPS Only) Lamp Wattage 05 = 50 Watts 07 = 70 Watts 10 = 100 Watts 15 = 150 Watts 17 = 175 Watts (MH Only) 25 = 250 Watts (MH Only)

Optical Assembly Options (Contd) TG = 7-3/4 in. Thermal Shock Resistant Globe TGP = TG with Polymeric Guard RCB = Enclosed High Bay Reflector RCG = RCB with Steel Wire Guard Mounting Style A2 = 3/4 in. Cone Top Pendant A3 = 1 in. Cone Top Pendant B2 = 34 in. Wall Mount B3 = 1 in. Wall Mount C2 = 34 in. Ceiling Mount C3 = 1 in. Ceiling Mount F2 = 34 in. Flexible Pendant F3 = 1 in. Flexible Pendant HV1 = Hazvertor Ring - Class I, Div. 2, Zone 2 L4 = 1-14 in. Straight Stanchion L5 = 1-12 in. Straight Stanchion P2 = 34 in. Rigid Pendant P3 = 1 in. Rigid Pendant S4 = 1-14 in. 25 Angle Stanchion S5 = 1-12 in. 25 Angle Stanchion Special Options T = Haz-Cote Custom Corrosion Coating (Consult Factory) Hazpak Options E = Hazpak with Clear Lamp E1 = Hazpak, Clear Lamp, Dome Reflector E2 = Hazpak, Clear Lamp, Angle Reflector D = Hazpak with Dual Arc Lamp D1 = Hazpak Dual Arc Lamp, Dome Reflector D2 = Hazpak, Dual Arc Lamp, Angle Reflector U = Hazpak, No Lamp Fusing Options * F = Single Fuse Block with Fuse FF = Double Fuse Block with Fuse CSA Certification C = CSA Nameplate

Ballast Circuit H = High Reactance C = Constant Wattage Autotransformer (CWA) (AII ballasts high power factor.) I = Constant Wattage Isolated (CWI) Voltage/Frequency 09 = 120/277/347V, 60Hz 12 = 120V, 60Hz 24 = 240V, 60Hz 27 = 277V, 60Hz 28 = 208V, 60Hz 34 = 347V, 60Hz 225 = 220V, 50Hz 245 = 240V, 50Hz Ballast Housing Style R = Refractor Globe Housing (150W HPS, 250W MH) Optical Assembly Options R1 = 7-3/4 in. Refractor Globe, Type I R3 = 7-3/4 in. Refractor Globe, Type III R5 = 7-3/4 in. Refractor Globe, Type V R1P = R1 with Polymeric Guard R3P = R3 with Polymeric Guard R5P = R5 with Polymeric Guard

10

11

12

13

*Not CSA certified in hazardous locations With appropriate fittings installed

43

Hazlux 3, Refractor Globe Housing Accessories


OUTLET BOXES
MOUNTING STYLE
Rigid Pendant

OUTLET BOXES
CAT. NO. CONDUIT HUB SIZE MOUNTING STYLE
Wall Mount

CAT. NO.

CONDUIT HUB SIZE

VP2 VP3
Cone Pendant

3/4'' 1''
Angle Stanchion

VB2 VB3 VS4 VS5


Straight Stanchion

3/4'' 1'' 3/4'' 1'' 3/4'' 1'' N.A.

VA2 VA3
Flexible Pendant

3/4'' 1'' 3/4'' 1''


Adaptor Ring

VF2 VF3
Ceiling Mount

VL4 VL5 HV1

VC2 VC3

3/4'' 1''

GLOBES OR REFRACTORS
CATALOGUE NO. DESCRIPTION

VGT31S VGT31TS VGL31R1 VGL31R3 VGL31R5 VRF31C2 VRF31C5

7-3/4 dia. Heat Resistant Globe (250W max.) 7-3/4 dia. Heat Resistant Globe (250W max.) coated with Tuff-Skin 7-3/4 dia. IES Type I Refractor Globe (250W max.) 7-3/4 dia. IES Type III Refractor Globe (250W max.) 7-3/4 dia. IES Type V Refractor Globe (250W max.) 12 dia. IES Type II Refractor, 7-3/4 Thread 12 dia. IES Type V Refractor, 7-3/4 Thread

REFLECTORS
CATALOGUE NO. DESCRIPTION

VR31P VRD31 VR31CB VRA31P

Standard Dome, Fiberglass Reinforced Polyester Deep Dome, Anodized Aluminum Enclosed High Bay, Anodized Aluminum with Lens 30 Angle Reflector, Fiberglass Reinforced Polyester

GUARDS
CATALOGUE NO. DESCRIPTION

VGU31RP VGU31R VGR48 VGR64

Polymeric Guard for VGT31S Globe and VGL31R Series Refractor Globes Cast Alum. Guard for VGT31S Globe and VGL31R Series Refractor Globes Steel Wire Guard for All VRF Series 12 Refractors Steel Wire Guard for VR31CB Enclosed High Bay Reflector

44

Refractor Globe Housing

Class I Zone 2, Groups IIC, IIB, IIA, Exn R II T3 (Restricted Breathing*) Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 3 Refractor Globe Housing Dimensions


R-TANK HOUSING WITH 7-3/4 REFRACTOR AND GUARD
133/8"
(340 mm)

13 / "
(340 mm)

3 8

13 /8"
(340 mm)

133/8"
(340 mm)

147/8"
(378 mm)

141/4"
(362 mm)

141/4"
(362 mm)

1811/16"
(475 mm)

141/2"
(368 mm)

165/8"
(422 mm)

RIGID PENDANT

FLEXIBLE PENDANT

CONE PENDANT

CEILING MOUNT

WALL MOUNT

161/8"
(410 mm)

153/4"
(400 mm)

133/8"
(340 mm)

153/16"
(386 mm)

153/16"
(386 mm)

143/4"
(375 mm)

25 STANCHION MOUNT

STRAIGHT STANCHION

HAZVERTOR RING

R-TANK HOUSING WITH 7-3/4 GLOBE AND GUARD


133/8"
(340 mm)

13 / "
(340 mm)

3 8

13 / "
(340 mm)

3 8

133/8"
(340 mm)

147/8"
(377 mm)

1811/16" 141/4"
(362 mm)

141/4"
(362 mm)

(475 mm)

141/2"
(368 mm)

165/8"
(422 mm)

RIGID PENDANT

FLEXIBLE PENDANT

CONE PENDANT

CEILING MOUNT

WALL MOUNT

161/8"
(410 mm)

153/4"
(400 mm)

133/8"
(340 mm)

153/16"
(391 mm)

153/16"
(386 mm)

143/4"
(375 mm)

25 STANCHION MOUNT

STRAIGHT STANCHION

HAZVERTOR RING

*With appropriate fittings installed

45

Hazlux 3, Large Housing, Fixture Assembly Sample

Mounting Style

HV1 Hazvertor

VP2 or VF2 Pendant

VA2 Rigid Pendant Cone

VC2 Ceiling Mount

VB2-OLD Wall Mount

VS5 Angle Stanchion

VL5 Straight Stanchion

Ballast Tank

L Tank

Globe or Refractor

VRF31C5

VGT31

VR31CB

Guard

VGR48

VGU31

VGR64 Wire Guard

Reflector

VRD31

VR31P Standard Dome

VRA31P 30 Angle Reflector

46

Large Housing

Class I Zone 2, Groups IIC, IIB, IIA, Exn R II T3 (Restricted Breathing) Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 3 Large Housing Catalogue Numbering System

D S 0 40 C 09 L - TGC - P2 E1 F C
1 2 3 4 5 6 7 8 9 11 12 13

1 2

Fixture Series D = Hazlux 3 Fixture Lamp Type S = High Pressure Sodium H = Metal Halide Starter Circuit/Quartz Options O = Standard Fixture P = Pulse Start (MH Only) Q = Quartz Auxiliary Option (Not Hazardous Rated) R = Instant Restart (HPS Only) J = Auto Shutoff Starter (HPS Only) Lamp Wattage 20 = 200 Watts 25 = 250 Watts 32 = 320 Watts (MH PS Only) 40 = 400 Watts Ballast Circuit H = High Reactance C = Constant Wattage Autotransformer (AII ballasts high power factor.) I = Constant Wattage Isolated (CWI) Voltage/Frequency 09 = 120/277/347V, 60Hz 12 = 120V, 60Hz 24 = 240V, 60Hz 27 = 277V, 60Hz 28 = 208V, 60Hz 34 = 347V, 60Hz 225 = 220V, 50Hz 245 = 240V, 50Hz Ballast Housing Style L = Large Housing (200-400W HPS; 400W MH) Optics and Guards R2 = 12 in. Glass Refractor Globe, Type II R5 = 12 in. Refractor Globe, Type V R2G = R2 with Steel Wire Guard R5G = R5 with Steel Wire Guard RCB = Enclosed High Bay Reflector R5P = RCB with Steel Wire Guard

Optics and Guards (Contd) TG = 7-3/4 in. Thermal Shock Resistant Globe TGC = TG with Cast Aluminum Guard SG = Tuffskin Coated Globe SGC = SG with Cast Aluminum Guard Mounting Style A2 = 3/4 in. Cone Top Pendant A3 = 1 in. Cone Top Pendant B2 = 34 in. Wall Mount B3 = 1 in. Wall Mount C2 = 34 in. Ceiling Mount C3 = 1 in. Ceiling Mount F2 = 34 in. Flexible Pendant F3 = 1 in. Flexible Pendant HV1 = Hazvertor Ring - Class I, Div. 2, Zone 2 L4 = 1-14 in. Straight Stanchion L5 = 1-12 in. Straight Stanchion P2 = 34 in. Rigid Pendant P3 = 1 in. Rigid Pendant S4 = 1-14 in. 25 Angle Stanchion S5 = 1-12 in. 25 Angle Stanchion Special Options T = Haz-Cote Custom Corrosion Coating (Consult Factory) Hazpak E = E1 = E2 = D = D1 = D2 = U = Options Hazpak with Clear Lamp Hazpak, Clear Lamp, Dome Reflector Hazpak Clear Lamp, Angle Reflector Hazpak with Dual Arc Lamp Hazpak, Dual Arc Lamp, Dome Reflector Hazpak, Dual Arc Lamp, Angle Reflector Hazpak, No Lamp

10

11

7 8

12

Fusing Options * F = Single Fuse Block with Fuse FF = Double Fuse Block with Fuse CSA Certification C = CSA Nameplate

13

*Not CSA certified in hazardous locations With appropriate fittings installed

47

Hazlux 3, Large Housing Accessories


OUTLET BOXES
MOUNTING STYLE
Rigid Pendant

OUTLET BOXES
CAT. NO. CONDUIT HUB SIZE MOUNTING STYLE
Wall Mount

CAT. NO.

CONDUIT HUB SIZE

VP2 VP3
Cone Pendant

3/4'' 1''
Angle Stanchion

VB2 VB3 VS4 VS5


Straight Stanchion

3/4'' 1'' 3/4'' 1'' 3/4'' 1'' N.A.

VA2 VA3
Flexible Pendant

3/4'' 1'' 3/4'' 1''


Adaptor Ring

VF2 VF3
Ceiling Mount

VL4 VL5

VC2 VC3

3/4'' 1''

HV1

GLOBES OR REFRACTORS
CATALOGUE NO. DESCRIPTION

VGT31 VGT31TS VRF31C2 VRF31C5

7-3/4 dia. Heat Resistant Globe (400W max.) 7-3/4 dia. Heat Resistant Globe (400W max.) coated with Tuff-Skin 12 dia. IES Type II Refractor, 7-3/4 Thread 12 dia. IES Type V Refractor, 7-3/4 Thread

REFLECTORS
CATALOGUE NO. DESCRIPTION

VR31P VRD31 VR31CB VRA31P

Standard Dome, Fiberglass Reinforced Polyester Deep Dome, Anodized Aluminum Enclosed High Bay, Anodized Aluminum with Lens 30 Angle Reflector, Fiberglass Reinforced Polyester

GUARDS
CATALOGUE NO. DESCRIPTION

VGU31 VGR48 VGR64

Cast Aluminum Guard for VGT31 Globe Steel Wire Guard for All VRF Series 12 Refractors Steel Wire Guard for VR31CB Enclosed High Bay Reflector

48

Large Housing

Class I Zone 2, Groups IIC, IIB, IIA, Exn R II T3 (Restricted Breathing*) Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G Class III UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 3, Large Housing Dimensions


LARGE BALLAST HOUSING WITH GLOBE AND GUARD
133/8" 133/8"
(340 mm) (340 mm)

133/8"
(340 mm)

147/8"
(378 mm)

97/8"
(251 mm)

143/8"
(365 mm)

211/2"
(546 mm)

221/8"

243/8"
(619 mm)

115/8"
(295 mm)

26"
(660 mm)

(562 mm)

RIGID PENDANT

CONE PENDANT

CEILING MOUNT

WALL MOUNT

161/8"
(410 mm)

153/4"
(400 mm)

133/8"
(340 mm)

23"
(584 mm)

23"
(584 mm)

233/8"
(594 mm)

25 STANCHION MOUNT

STRAIGHT STANCHION

HAZVERTOR RING

LARGE BALLAST HOUSING WITH 12 REFRACTOR AND GLOBE


133/8" 133/8"
(340 mm) (340 mm)

133/8"
(340 mm)

147/8"
(378 mm)

207/8"
(530 mm)

253/8"
(644 mm)

211/2"
(546 mm)

233/4"
(603 mm)

RIGID PENDANT

CONE PENDANT

CEILING MOUNT

WALL MOUNT

161/8"
(410 mm)

153/4"
(400 mm)

133/8"
(340 mm)

223/8"
(568 mm)

223/8"
(568 mm)

213/4"
(552 mm)

25 STANCHION MOUNT

STRAIGHT STANCHION

HAZVERTOR RING

*With appropriate fittings installed

49

50

Class I Zone 2, Groups IIC, IIB, IIA, ExnR = T3 200W-300W Incadescent (Restricted Breathing) ExnR = T4 75W-150W Incadescent (Restricted Breathing) ExnR = T5 13W-56W Fluorescent (Restricted Breathing) Division 2, Groups A, B, C and D Class II Division 1, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M4 lighting fixtures have a compact, low profile design that is ideally suited for areas where space or fixture weight is restricted. Available for use with incandescent and fluorescent lamps, the Hazlux M4 fixture with fluorescent lamps is extremely energy efficient.

Easy-to-assemble, modular construction Fully threaded glass globes, refractors and silicone rubber gaskets seal out dirt, dust and moisture Bright white FRP material reflectors optimize light output, resist corrosion and abuse Clear glass globes are standard; tempered globes, coloured glass globes and plastic globes are also available 1-3/4 deep boxes are standard on ceiling and wall mount fixtures; 3 deep boxes available for added wiring room Four mounting styles pendant, ceiling, wall, angle stanchion to meet all mounting needs

M3/3
Fluorescent

Polycarbonate guards are corrosion and impact resistant and do not interfere with globe seal

Incandescent two basic sizes cover all popular wattages up to 300 watts

factory-wired integral ballasts for easy installation 10,000 hour rated lamp life extremely energy efficient one or two 13, 22 and 28 watt lamps provide up to 44 watts of fluorescent light 22, 28 and 44 watt fixtures start and operate reliably in cold temperature applications (-29C)

51

Hazlux M4 Incandescent Fixture Assembly Sample

Fixture Assembly

VXB Wall Mount Bracket Arm

VXA4 Stanchion Bracket Arm

VXF Ceiling Junction Box

Mounting Style

VXH15

VDA15 Rigid Pendant

Globe or Refractor

VGT15

VGL15R1

VGT15

VGL15R1

Guard

VGU15P Polymeric Guard

VGU15P Polymeric Guard

VGU15P Polymeric Guard

VGU15P Polymeric Guard

Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

52

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Incandescent Hazlux M4 Incandescent Catalogue Numbering System

VDA
1

2
2

5
3

GP
4

RD
5

VXHF
1

2
2

5
3

GP
4

RD
5

4 Fixture Series and Mounting Style VDA = M4 Incandescent Pendant Mount Fixture VXH = M4 Incandescent Fixture Body for Ceiling, Wall or Stanchion Mount VXHA = M4 Incandescent Stanchion Mount Fixture VXHB = M4 Incandescent Wall Mount Fixture (No Box) VXHBF = M4 Incandescent Wall Mount Fixture (With Box) VXHF = Incandescent M4 Ceiling Mount Fixture (With Box)
Hub Size 2 = 3/4 in. NPT Hub 4 = 1-1/4 in. NPT Hub

M3/3
Optics and G = GP = TG = TGP = ACG = BCG = GCG = RCG = ACGP = BCGP = GCGP = RCGP = R1** = R3** = R5** = ** 150 Watt Maximum

Guards Clear Glass Globe Clear Globe and Polymeric Guard Tempered Glass Globe Tempered Glass Globe and Polymeric Guard Amber Glass Globe Blue Glass Globe Green Glass Globe Red Glass Globe Amber Glass Globe and Polymeric Guard Blue Glass Globe and Polymeric Guard Green Glass Globe and Polymeric Guard Red Glass Globe and Polymeric Guard Type I Threaded Glass Refractor Type III Threaded Glass Refractor Type V Threaded Glass Refractor

Lamp Wattage 5 = 150 Watt Maximum 2 = 200 to 300 Watt

Reflector Options RD = Dome Reflector RA = Angle Reflector

53

Hazlux M4 Incandescent Accessories


FIXTURE ASSEMBLY
CAT. NO.
Wall Mount Bracket Arm

MOUNTING STYLE
CONDUIT HUB SIZE
Pendant Mount

CAT.NO.

WATT. MAX. LAMP SIZE

CONDUIT HUB SIZE

VXB
Stanchion Bracket Arm

N.A.

VDA15 VDA25 VDA12 VDA22

150W 150W 200-300W 200-300W 150W 200-300W

1/2'' 3/4'' 1/2'' 3/4'' N.A. N.A.

VXA4

1-1/4''

Ceiling, Wall or Stanchion Mount

VXH15 VXH12

JUNCTION BOX FOR WALL OR CEILING


CAT. NO. 4 Hubs
1-3/4 Inside Depth

COVERS and GASKETS


CAT. NO. DESCRIPTION
Fixture Hanger Hub Cover for VXF and VXFD Boxes Gasket for Hub Covers, Flat Covers and Bracket Arms

CAT. NO. 5 Hubs

CONDUIT HUB SIZE

CONDUIT HUB SIZE

VXF10 VXF20

VXFT10 VXFT20

1/2'' 3/4''

VHC2

3/4''

GASK643

N.A.

GLASS GLOBES
CAT. NO., 150W MAX. LAMP SIZE CAT. NO., 200-300W MAX. LAMP SIZE DESCRIPTION

VGT15 VGT15R VG15G VGT15B VGT15A

VGT22 VGT22R VGT22G VGT22B VGT22A

Clear, Heat Resistant Red Green Blue Amber

REFLECTORS
CAT. NO., 150W MAX. LAMP SIZE CAT. NO., 200-300W MAX. LAMP SIZE DESCRIPTION

VR15P VRA15P

VR22P VRA22P

Dome Angled

GUARDS
CAT. NO., 150W MAX. LAMP SIZE CAT. NO., 200-300W MAX. LAMP SIZE DESCRIPTION

VGU15P

VGU22P

Polymeric Guard

54

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Incandescent Hazlux M4 Incandescent Dimensions

115/8"
(295 mm)

12 1/2"
(318 mm)

10 3/8"
(264 mm)

11 3/16"
(284 mm)

8"
(203 mm)

8"
(203 mm)

4 5/16"
(110 mm)

4 5/16"
(110 mm)

6 /4"
(159 mm)

5 1/8"
(130 mm)

7 1/4"
(184 mm)

515/16"
(151 mm)

6 1/2"
(165 mm)

513/16"
(148 mm)

8 1/8"
(206 mm)

615/16"
(176 mm)

ANGLE STANCHION MOUNT 150 WATTS MAXIMUM

ANGLE STANCHION MOUNT 300 WATTS MAXIMUM AND FLUORESCENT

PENDANT MOUNT 150 WATTS MAXIMUM

PENDANT MOUNT 300 WATTS MAXIMUM AND FLUORESCENT

111/16"
(281 mm)

10 3/16"
(259 mm)

9 15/16"
(252 mm)

10 1/16"
(256 mm)

115/16" 413/16"
(122 mm)

2 1/2"
(66 mm)

15"
(381 mm)

16 7/8"
(429 mm)

DOME REFLECTOR 150 WATTS MAXIMUM

DOME REFLECTOR 300 WATTS MAXIMUM AND FLUORESCENT

M3/3
(140 mm)

51/2"

(49 mm)

9 11/16"

10 7/8"
(276 mm)

(246 mm)

ANGLE DOME 150 WATTS MAXIMUM

ANGLE REFLECTOR 300 WATTS MAXIMUM AND FLUORESCENT

8 13/16"
(224 mm)

6 7/8"
(175 mm)

3 1/2"
(90 mm)

4 3/16"
m 6" m )
(106 mm)
15

4 3/16"

4 3/16"
(106 mm)

/1

(106 mm)

(1 25

12 13/16"
(325 mm)

.201"dia. hole 10 7/8"


(276 mm) (5 mm)

WALL MOUNT WITH BOX

WALL MOUNT WITHOUT BOX

5"
(127 mm)

1 7/8"
(48 mm)

(203 mm)

CEILING MOUNT

JUNCTION BOX FOR WALL OR CEILING MOUNT

(1 25

8"

(106 mm)

m 6" m )

15

/1

4 3/16"

55

Hazlux M4 Fluorescent Fixture Assembly Sample

Fixture Assembly

VXB Wall Mount Bracket Arm

VXA4 Stanchion Bracket Arm

VXF Ceiling Junction Box

Mounting Style

VFH

VFA Rigid Pendant

Globe or Refractor

VGT22

VGT22

Guard

VGU22P Polymeric Guard

VGU22P Polymeric Guard

Reflector

VR22P Standard Dome

VRA22P 30 Angle Reflector

VR22P Standard Dome

VRA22P 30 Angle Reflector

56

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1, Groups E, F and G UL844 NEMA 4X, IP66

F l u o r e s c e n t Hazlux M4 Fluorescent Catalogue Numbering System

VFH 2
1 2

44
3

12
4

GP
5

RD
6

D
7

Fixture Series and Mounting Style VFA = M4 Fluorescent Pendant Mount VFH = M4 Fluorescent Body for Ceiling, Wall or Stanchion Mount VFHA = M4 Fluorescent Stanchion Mount VFHB = M4 Fluorescent Wall Mount (No Box) VFHBF = M4 Fluorescent Wall Mount (Std Box) VFHBFD = M4 Fluorescent Wall Mount (Deep Box) VFHF = M4 Fluorescent Ceiling Mount (Std Box) VFHFD = M4 Fluorescent Wall Mount (Deep Box)

Hub Size 2 = 3/4 in. NPT Hub 4 = 1-1/4 in. NPT Hub

M3/3
6 7

Optics and Guards G = Clear Glass Globe GP = Clear Globe and Polymeric Guard TG = Tempered Glass Globe TGP = Tempered Glass Globe and Polymeric Guard ACG = Amber Glass Globe* BCG = Blue Glass Globe* GCG = Green Glass Globe* RCG = Red Glass Globe* ACGP = Amber Glass Globe and Polymeric Guard* BCGP = Blue Glass Globe and Polymeric Guard* GCGP = Green Glass Globe and Polymeric Guard* RCGP = Red Glass Globe and Polymeric Guard* *CSA Certification Pending on Coloured Globes.

Lamp Wattage 13 = 13 Watt 22 = 22 Watt 26 = 26 Watt 28 = 28 Watt 44 = 44 Watt

(One 13W lamp) (One 22W lamp) (Two 13W lamps) (One 28W lamp) (Two 22W lamps)

Reflector Options RD = Dome Reflector RA = Angle Reflector

Voltage 12 = 120 VAC

Packaging Options D = Hazpak Packaging (Completely Assembled with Lamps in One Carton) P = PROJECPAK Packaging (All Components, Including Lamp(s), in One Carton, Unassembled) Note: If no packaging code is specified, fixture components will be shipped in separate cartons. All fixtures and fixture housings include lamps.

57

Hazlux M4 Fluorescent Accessories


FIXTURE ASSEMBLY
CAT. NO.
Wall Mount Bracket Arm

MOUNTING STYLE
CONDUIT HUB SIZE CATALOGUE NO. CONDUIT HUB SIZE

VXB
Stanchion Bracket Arm

N.A.

VFH

N.A.

VXA4

1-1/4''

VFA

1/2''

JUNCTION BOX FOR WALL OR CEILING


CAT. NO. 4 Hubs
1-3/4 Inside Depth

COVERS and GASKETS


CAT. NO. DESCRIPTION
Fixture Hanger Hub Cover for VXF Boxes Gasket for Hub Covers, Flat Covers and Bracket Arms

CAT. NO. 5 Hubs

CONDUIT HUB SIZE

CONDUIT HUB SIZE

VXF10 VXF20

VXFT10 VXFT20

1/2'' 3/4''

VHC1 VHC2

1/2'' 3/4''

GASK643

N.A.

GLASS GLOBES
CAT. NO., 150W MAX. LAMP SIZE CAT. NO., 200-300W MAX. LAMP SIZE DESCRIPTION

VGT15 VGT15R VG15G VGT15B VGT15A VRE22

VGT22 VGT22R VGT22G VGT22B VGT22A

Clear, Heat Resistant Red Green Blue Amber Three Sided Exit Sign

REFLECTORS
CAT. NO., 150W MAX. LAMP SIZE CAT. NO., 200-300W MAX. LAMP SIZE DESCRIPTION

VR22P VRA22P

Dome Angled

GUARDS
CAT. NO., 150W MAX. LAMP SIZE CAT. NO., 200-300W MAX. LAMP SIZE DESCRIPTION

VGU22P

Polymeric Guard

58

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1, Groups E, F and G UL844 NEMA 4X, IP66

F l u o r e s c e n t Hazlux M4 Fluorescent Dimensions

115/8"
(295 mm)

12 1/2"
(318 mm)

10 3/8"
(264 mm)

11 3/16"
(284 mm)

8"
(203 mm)

8"
(203 mm)

4 5/16"
(110 mm)

4 5/16"
(110 mm)

6 /4"
(159 mm)

5 1/8"
(130 mm)

7 1/4"
(184 mm)

515/16"
(151 mm)

6 1/2"
(165 mm)

513/16"
(148 mm)

8 1/8"
(206 mm)

615/16"
(176 mm)

ANGLE STANCHION MOUNT 150 WATTS MAXIMUM

ANGLE STANCHION MOUNT 300 WATTS MAXIMUM AND FLUORESCENT

PENDANT MOUNT 150 WATTS MAXIMUM

PENDANT MOUNT 300 WATTS MAXIMUM AND FLUORESCENT

111/16"
(281 mm)

10 3/16"
(259 mm)

9 15/16"
(252 mm)

10 1/16"
(256 mm)

115/16" 413/16"
(122 mm)

2 1/2"
(66 mm)

15"
(381 mm)

16 7/8"
(429 mm)

DOME REFLECTOR 150 WATTS MAXIMUM

DOME REFLECTOR 300 WATTS MAXIMUM AND FLUORESCENT

M3/3
(140 mm)

51/2"

(49 mm)

9 11/16"

10 7/8"
(276 mm)

(246 mm)

ANGLE DOME 150 WATTS MAXIMUM

ANGLE REFLECTOR 300 WATTS MAXIMUM AND FLUORESCENT

8 13/16"
(224 mm)

6 7/8"
(175 mm)

3 1/2"
(90 mm)

4 3/16"
m 6" m )
(106 mm)
15

4 3/16"

4 3/16"
(106 mm)

/1

(106 mm)

(1 25

12 13/16"
(325 mm)

.201"dia. hole 10 7/8"


(276 mm) (5 mm)

WALL MOUNT WITH BOX

WALL MOUNT WITHOUT BOX

5"
(127 mm)

1 7/8"
(48 mm)

(203 mm)

CEILING MOUNT

JUNCTION BOX FOR WALL OR CEILING MOUNT

(1 25

8"

(106 mm)

m 6" m )

15

/1

4 3/16"

59

The HazFlash M4 strobe lighting fixture is an enclosed and gasketed fixture that is suitable for use in marine and wet locations as well as in a wide range of industrial facilities. Two models are available: the VXS for outdoor, wet and marine locations and the DXS for Class I, Zone 2, Division 2 and Class II, Division I locations. Available in a choice of five lens colours, both models provide 60 flashes per minute and are ideally suited for use as a warning of unsafe conditions in areas where noise prevents audible signals from being heard.

60

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1, Groups E, F and G Enclosed and Gasketed Outdoor Wet Locations, NEMA 3R Outdoor Marine, NEMA 4X IP66

H a z F l a s h HazFlash M4 Catalogue Numbering System

VXS
1

6
2

1
3

R
4

GP - P2
5 6

SR
7

5 Fixture Series VXS = HazFlash M4 Adverse location Xenon Strobe Light DXS = HazFlash M4 Class I, Zone 2, Div. 2; Class II Xenon Strobe
Flash Rate 6 = 60 Flashes per Minute

Optics and G = GP = TG = TGP =

Guards Polycarbonate Globe (Standard) Polycarbonate Globe and Polymeric Guard Tempered Glass Globe Tempered Globe and Polymeric Guard

Electrical Ratings 1 = 120 Volts AC, 50/60 Hz 2 = 240 Volts AC, 50/60 Hz 8 = 10-30 Volts DC 9 = 90-130 Volts DC

M3/3
7

Mounting Style P2 = 3/4 in. Pendant Mount C2 = 3/4 in. Ceiling Mount B2 = 3/4 in. Wall Mount with Box S4 = 1-1/4 in. Angle Stanchion Mount

Lens Colour R = Red B = Blue C = Clear G = Green A = Amber

Options SR = Sealing Ring Kit for Inverted Mounting (Maintains Marine Listing in Globe Up Position)

61

Hazflash M4 Accessories
VXS STROBE LIGHT REPLACEMENT PARTS
CATALOGUE NUMBER DESCRIPTION

XSFT XSFL-R XSFL-B XSFL-C XSFL-G XSFL-A VGU-15P VGT15 VGL15P SRKIT-1

Flash Tube Fresnel Lens Red Fresnel Lens Blue Fresnel Lens Clear Fresnel Lens Green Fresnel Lens Amber Polycarbonate Guard Tempered Glass Globe Polycarbonate Globe Sealing Ring Kit includes sealing ring and gasket

62

Class I Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1, Groups E, F and G Enclosed and Gasketed Outdoor Wet Locations, NEMA 3R Outdoor Marine, NEMA 4X, IP66

H a z F l a s h HazFlash M4 Dimensions

115/8"
(295 mm)

12 1/2"
(318 mm)

10 3/8"
(264 mm)

11 3/16"
(284 mm)

8"
(203 mm)

8"
(203 mm)

4 5/16"
(110 mm)

4 5/16"
(110 mm)

6 /4"
(159 mm)

5 1/8"
(130 mm)

7 1/4"
(184 mm)

515/16"
(151 mm)

6 1/2"
(165 mm)

513/16"
(148 mm)

8 1/8"
(206 mm)

615/16"
(176 mm)

ANGLE STANCHION MOUNT 150 WATTS MAXIMUM

ANGLE STANCHION MOUNT 300 WATTS MAXIMUM AND FLUORESCENT

PENDANT MOUNT 150 WATTS MAXIMUM

PENDANT MOUNT 300 WATTS MAXIMUM AND FLUORESCENT

8 13/16"
(224 mm)

4 3/16"
(106 mm)

12 13/16"
(325 mm)

M3/3
6 7/8"
(175 mm)

3 1/2"
(90 mm)

4 3/16"

4 3/16" .201"dia. hole


(5 mm)

(1 25

m 6" m )

15

/1

(106 mm)

(106 mm)

10 7/8"

(276 mm)

WALL MOUNT WITH BOX

WALL MOUNT WITHOUT BOX

5"
(127 mm)

1 7/8"
(48 mm)

(203 mm)

CEILING MOUNT

JUNCTION BOX FOR WALL OR CEILING MOUNT

(1 25

8"

(106 mm)

15

4 3/16"

m 6" m )

/1

63

64

Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M5 and Hazlux 5 fixtures are certified for use in Class I, Division 1 and Zone 2 hazardous locations - the most severe hazardous locations and adverse environments. In addition to meeting these strength, heat and electrical criteria, these fixtures are designed and tested for the unusually harsh conditions present in the Canadian workplace including rain, wind, salt, air and dust.

Hazlux M5 Compact, low profile design highly cost efficient for areas where space or fixture weight is restricted Easy to install electromechanical connection block, self-aligning refractors and prewired ballast Unipak option provides factory assembled, pre-lamped fixtures proven installation savings of 1/2 hour per fixture Light sources HID metal halide and high pressure sodium; fluorescent and incandescent Superior thermal design for use in elevated temperature environments also provides cooler operating performance at normal ambient temperatures Self-aligning high efficiency fluted glass globes and computerdesigned fiberglass-reinforced polyester reflectors provide superior photometrics

M3/3

Hazlux 5 Hose-down tested to allow easy removal of chemicals and residue that collect on fixtures 40C ambient certified and listed

High ambient temperature fixtures available (55C and 65C) High strength mechanical mountings to withstand ice and strong wind loads Heat tempered glass for greater strength and thermal shock resistance Instant restart available to prevent unnecessary downtime due to minor power outages (HPS only) Auxiliary quartz lamp available to provide temporary lighting after power outages

65

Hazlux M5 Fixture Assembly Sample

Mounting Style

XP2 Pendant Mount

XS4 Stanchion Mount

XC2 Ceiling Mount

XB2 Wall/Bulkhead Mount

XJ2 Wall/Bulkhead Mount

Guard

Globe

Fixture

XGU15 Cast Guard

Reflector

VR15P Standard Dome

VRA15P 30 Angle Reflector

66

Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M5 Catalogue Numbering System


High Pressure Sodium

X
1

S
2

M
3

35
4

P
5

120 - G - C2
6 7 8

E
10

C
11

Incandescent Only

X
1

I
2

M
3

10
4

120 - G - C2
6 7 8

E
10

C
11

Fluorescent Only

X
1 1 2

F
2

B
3

18
4

P
5 6 7

12 - G - C2
6 7 8
Voltage 120 = 120 Volt

E
10

C
11

Fixture Series X = Hazlux M5 Fixture Lamp Type S = High Pressure Sodium F = Fluorescent I = Incandescent Lampholder Type M = Medium Base Lampholder B = Bi Pin Type (Fluorescent) Lamp Wattage 09 = 9 watt (Fluorescent) 13 = 13 watt (Fluorescent) 18 = 18 watt (Fluorescent) 26 = 26 watt (Fluorescent) 100 = 100 watt (Incandescent) 150 = 150 watt (Incandescent) 03 = 35 watt (HPS) 05 = 50 watt (HPS) 07 = 70 watt (HPS) 10 = 100 watt (HPS) 15 = 150 watt (HPS)

M3/3
8 9 10 11
CSA Certification C = CSA Nameplate

Optics and Guards G = Cast Guard (Omit G if Guard is Not Required) Mounting Style P2 = 3/4 in. Rigid Pendant P3 =1 in. Rigid Pendant C2 = 3/4 in. Ceiling C3 = 1 in. Ceiling B2 = 3/4 in. Wall B3 = 1 in. Wall J2 = 3/4 in. Bulkhead J3 = 1 in. Bulkhead S4 = 1-1/4 in. Stanchion S5 = 1-1/2 in. Stanchion Special Options T = HAZ-COTE Custom Corrosion Coating on all Aluminum Parts (Consult Factory) Hazpak Options D = Hazpak with Diffuse Coated Lamp E = Hazpak with Clear Lamp

Ballast Circuit P = Reactor Type (HPS and Fluorescent)

Note: Verify hazardous location certification with your requirements on Hazlux Certification Guide general information on page 79.

67

Hazlux M5 Accessories
OUTLET BOXES Designed for all Hazlux M5 Ballasts Housings.
MOUNTING STYLE
Pendant Mount

OUTLET BOXES Designed for all Hazlux M5 Ballasts Housings.


MOUNTING STYLE
Ceiling Mount

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

XP2 XP3

3/4'' 1''

1 1
Wall Mount

XC2 XC3

3/4'' 1''

1 1

Stanchion Mount

XB2 XB3 XS4 XS5 1-1/4'' 1-1/2'' 1 1


Bulkhead Mount

3/4'' 1''

1 1

XJ2 XJ3

3/4'' 1''

1 1

Outlet Boxes include Female Electrical connectors and appropriate Close-Up Plugs.

GUARDS
CATALOGUE NO. DESCRIPTION

XGU15

Cast Aluminum, Powder Finish

REPLACEMENT GLOBE ASSEMBLIES


CATALOGUE NO. DESCRIPTION

XGSA15

Hazlux M5 replacement globe assembly 35-150 watts

REFLECTORS
CATALOGUE NO. DESCRIPTION

VR15P VRA15P

Standard Dome Fiber Glass Reinforced Polyester 30 Angle Reflector Fiberglass Reinforced Polyester

68

Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux M5 Dimensions

8 1/4"
(210 mm)

8 1/4"
(210 mm)

8 1/4"
(210 mm)

2 1/4"
(57 mm)

2 /16"
(68 mm)

2 9/16"
(68 mm)

*
6 3/8"
(162 mm)

*
6 3/8"
(162 mm)

*
4 7/8"
(124 mm)

6 9/16"
(167 mm)

3/8" (9.5 mm) diameter Holes on a 6" (152 mm) diameter B.C.

Four

RIGID PENDANT GLOBE/GUARD

CEILING MOUNT GLOBE/GUARD

CEILING MOUNT GLOBE/GUARD WITH DOME REFLECTOR

14 5/8"
(371 mm)

(25 mm)

M3/3
14 7/8"
(378 mm)

10 3/4"

14 5/8"

(371 mm)

(273 mm)

1"

10 1/2"

1 7/8"
(48 mm)

(267 mm)

10 1/2"
(267 mm)

1 7/8"
(48 mm)

9 3/8"

5 7/16"
(141 mm)

(238 mm)

9 3/8"
(238 mm)

8 1/4"
(210 mm)

*
6 9/16"
(167 mm)

8 1/4"
(210 mm)

*
6 3/8"
(162 mm)

3 3/16"
(81 mm)

8 1/4"
(210 mm)

*
6 9/16" 15"
(381 mm)

9 3/4"
(248 mm)

(167 mm)

18"
(457 mm)

17 1/4"
(438 mm)

15 / "
(403 mm)

7 8

20 7/8"
(530 mm)

STANCHION MOUNT GLOBE/GUARD

WALL MOUNT GLOBE/GUARD WITH 30 ANGLE REFLECTOR

STANCHION MOUNT GLOBE/GUARD WITH 30 ANGLE REFLECTOR

* Tank Dim: HPS 9 / 229 mm, Incandescent and Fluorescent 5 11/16 / 144 mm

69

The HazFlash M5 strobe lighting fixture is an enclosed and gasketed fixture that is suitable for use in marine and wet locations as well as in a wide range of industrial facilities. Available in a choice of five lens colours with a flash rate of 60 flashes per minute, the HazFlash M5 is ideally suited for use as a warning of unsafe conditions in areas where noise prevents audible signals from being heard.

70

Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

H a z F l a s h HazFlash M5 Catalogue Numbering System

XXS
1

6
2

1
3

R
4

G - P2
5 6

SR
7

Fixture Series XXS = HazFlash M5 Xenon Strobe

Optics and Guards G = Cast Guard (Omit G if guard is not required.)

Flash Rate 6 = 60 Flashes per Minute

Voltage/Frequency 1 = 120 Volts AC, 50/60 Hz (Standard) 2 = 240 Volts AC, 50/60 Hz 8 = 10 - 30 Volts DC 9 = 90 - 130 Volts DC

Lens Colour R = Red B = Blue C = Clear G = Green A = Amber

M3/3
7

Mounting Style P2 = 3/4 in. Pendant Mount P3 = 1 in. Pendant Mount C2 = 3/4 in. Ceiling Mount C3 = 1 in. Ceiling Mount B2 = 3/4 in. Wall Mount with Box B3 = 1 in. Wall Mount with Box J2 = 3/4 in. Bulkhead Mount J3 = 1 in. Bulkhead Mount S4 = 1-1/4 in. Angle Stanchion Mount S5 = 1-1/2 in. Angle Stanchion Mount

Options SR = Sealing Ring Kit for Inverted Mounting (Maintains Marine Listing in Globe Up Position)

71

HazFlash M5 Accessories
OUTLET BOXES Designed for all Hazlux M5 Ballasts Housings.
MOUNTING STYLE
Pendant Mount

OUTLET BOXES Designed for all Hazlux M5 Ballasts Housings.


MOUNTING STYLE
Ceiling Mount

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

XP2 XP3

3/4'' 1''

1 1
Wall Mount

XC2 XC3

3/4'' 1''

1 1

Stanchion Mount

XB2 XB3 XS4 XS5 1-1/4'' 1-1/2'' 1 1


Bulkhead Mount

3/4'' 1''

1 1

XJ2 XJ3

3/4'' 1''

1 1

Outlet Boxes include Female Electrical connectors and appropriate Close-Up Plugs.

GUARDS
CATALOGUE NO. DESCRIPTION

XGU15

Cast Aluminum, Powder Finish

REPLACEMENT GLOBE ASSEMBLIES


CATALOGUE NO. DESCRIPTION

XGSA15

Hazlux M5 replacement globe assembly 35-150 watts

72

Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

H a z F l a s h HazFlash M5 Dimensions

8 1/4"
(210 mm)

8 1/4"
(210 mm)

2 1/4"
(57 mm)

2 9/16"
(68 mm)

*
6 3/8"
(162 mm)
3/8" (9.5 mm) diameter Holes on a 6" (152 mm) diameter B.C.

*
Four

6 3/8"
(162 mm)

RIGID PENDANT GLOBE/GUARD

CEILING MOUNT GLOBE/GUARD

14 5/8"
(371 mm)

M3/3
14 7/8"
(378 mm)

10 3/4"

(273 mm)

1"

10 1/2"
(267 mm)

1 7/8"
(48 mm)

(25 mm)

9 3/8"
(238 mm)

5 7/16"
(141 mm)

8 1/4"
(210 mm)

*
8 1/4" 6 /"
(162 mm)
3 8

(210 mm)

*
6 9/16"
(167 mm)

17 1/4"
(438 mm)

STANCHION MOUNT GLOBE/GUARD

WALL MOUNT GLOBE/GUARD

* Tank Dim: HPS 9 / 229 mm, Incandescent and Fluorescent 5 11/16 / 144 mm

73

Hazlux 5 Fixture Assembly Sample

Mounting Style

XP2 Pendant Mount

XS4 Stanchion Mount

XC2 Ceiling Mount

XB2 Wall/Bulkhead Mount

XJ2 Wall/Bulkhead Mount

Special Application Floodlight

Fixture and Globe

(See Accessories page for details.)

Guard

XGU44 Polymeric Guard

Reflector

VR31P Standard Dome

VRA31P 30 Angle Reflector

74

Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 5 Catalogue Numbering System

X
1

S
2

Q
3

07
4

H
5

090 - G - C2 - E
6 7 8 10

C
11

Fixture Series X = Hazlux 5 Fixture Lamp Type S = High Pressure Sodium H = Metal Halide Starter Circuit/Quartz Options O = Standard Fixture P = Pulse Start (MH Only) Q = Fixture with Auxiliary Quartz Option R = Fixture with Instant Restart Option (70, 100 and 150 HPS Only) Lamp Wattage 05 = 50 watt 07 = 70 watt 10 = 100 watt 15 = 150 watt 17 = 175 watt (MH Only) 25 = 250 watt 40 = 400 watt

Guard G = Cast Guard (omit G if Guard not required)

M3/3
9 10 11
CSA Certification C = CSA Nameplate

Mounting Style P2 = 3/4 in. Pendant P3 = 1 in. Pendant C2 = 3/4 in. Ceiling C3 = 1 in. Ceiling B2 = 3/4 in. Wall B3 = 1 in. Wall J2 = 3/4 in. Bulkhead J3 = 1 in. Bulkhead S4 = 1-1/4 in. Stanchion S5 = 1-1/2 in. Stanchion

Special Options T = HAZ-COTE Custom Corrosion Coating on All Aluminum Parts (Consult Factory) Hazpak Options D = Hazpak with Diffuse Coated Lamp E = Hazpak with Clear Lamp

Ballast Circuit C = Constant Wattage Auto Transformer (CWA) I = Constant Wattage Insulated Transformer (CWI) H = High Reactance or Reactor (All ballasts high power factor.) Voltage 090 120 240 280 340 480

Note: Verify hazardous location certification with your requirements on Hazlux Certification Guide general information on page 79.

= = = = = =

120/277/347 Volt, 60Hz 120 Volt 240 Volt 208 Volt 347 Volt 480 Volt

75

Hazlux 5 Accessories
OUTLET BOXES Designed for all Hazlux 5 Ballasts Housings.
MOUNTING STYLE
Pendant Mount

OUTLET BOXES Designed for all Hazlux 5 Ballasts Housings.


MOUNTING STYLE
Ceiling Mount

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

CATALOGUE NO.

CONDUIT HUB SIZE

STD. PKG.

XP2 XP3
Stanchion Mount

3/4'' 1''

1 1
Wall Mount

XC2 XC3 XB2 XB3


Bulkhead Mount

3/4'' 1'' 3/4'' 1'' 3/4'' 1''


STD. PKG

1 1 1 1 1 1

XS4 XS5

1-1/4'' 1-1/2''

1 1

Outlet Boxes include Female Electrical connectors and appropriate Close-Up Plugs.

REFLECTORS
Catalogue Number Description

XJ2 XJ3

VR31P VRD31 VRA31P

Standard Dome Fiberglass Reinforced Polyester Finish Deep Dome Steel with Anodized Aluminum Finish 30 Angle Reflector, Fiberglass Reinforced Polyester Finish

1 1 1

GUARDS
CATALOGUE NO. DESCRIPTION

XGU44 Cast Aluminum Guard VGU31*


* Used on all 400 watt fixtures and 200w thru 250w HPS, 250w MHPS

REPLACEMENT GLOBE ASSEMBLIES


CATALOGUE NO. DESCRIPTION

XGSA44 XGSA44A

Hazlux 5 replacement globe assembly250 MH 150 HPS Hazlux 5 replacement globe assembly400 watts and 250 HPS

HAZLUX 5 FLOODLIGHT (Trunnion Mount) AND REPLACEMENT GLOBE ASSEMBLIES


CATALOGUE NO. LAMP TYPE / WATTS

XS005H030 XS007H040-G-P2TRE XS010H040-G-P2-TR XS015H040-G-P2TRE XS025C040-G-P2TRE XS040C040-G-P2TRE XH017C040-G-P2TRE XH025C040-G-P2TRE XH040C040-G-P2TRE VRA31 VR31 XGU44 (50-150 HPS, 175/250 MH or 100-250 MV) VGU31 (250/400 HPS, 400 MV or 400 MH)
Note: Fixture shown with Dome Reflector and Guard. These are not included in the Catalogue Numbers above.

High Pressure Sodium / 50 High Pressure Sodium / 70 High Pressure Sodium / 100 High Pressure Sodium / 150 High Pressure Sodium / 250 High Pressure Sodium / 400 Metal halide / 175 Metal halide / 250 Metal halide / 400 Angle Reflector Dome Reflector Cast Guard Cast Guard

76

Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 5 Dimensions

16 19/32"
(421 mm)

11 11/16"
(297 mm)

10 3/4"
(273 mm)

11 11/16"
(297 mm)

5 9/16"
(141 mm)

2 9/16"
(65 mm)

8 5/8"
(219 mm)

8 5/8"
(219 mm)

8 5/8"
(219 mm)

19 13/16"
(503 mm)

20 1/8"
(511 mm)

8 15/16"
(227 mm)

8 15/16"
(227 mm)

8 15/16"
(227 mm)

5"
PENDANT MOUNT WITH GLOBE AND GUARD
(127 mm)

11 11/16"
(297 mm)

5 3/8"
(137 mm)

4"
(102 mm)

WALL MOUNT WITH GLOBE AND GUARD

CEILING MOUNT WITH GLOBE AND GUARD

3 5/8"
(92 mm)

M3/3
20 19/32"
(523 mm)

11 3/8"
(289 mm)

14 3/16"
(360 mm)

10 1/2" 9 1/2"

(267 mm)

(241 mm)

1 7/8" 11 11/16"
(297 mm) (48 mm)

8 5/8"
(219 mm)

18 1/2" 8 15/16" (470 mm)


(227 mm)

11 11/16"
(297 mm)

8 5/8"
(219 mm)

18 / "
(460 mm)

3 32

26 7/16"
(672 mm)

26 29/32"
(683 mm)

5"
(127 mm)

5"
(127 mm)

8 15/16"
(227 mm)

13 3/4" 13 3/4"
(349 mm)

20 1/8"
(511 mm)

(349 mm)

18 1/8"
(460 mm)

20 1/8"
(511 mm)

BULKHEAD MOUNT WITH GLOBE, GUARD AND REFLECTOR

STANCHION MOUNT WITH GLOBE, GUARD AND REFLECTOR

77

Hazlux 5 Dimensions

20 13/16"
(528 mm)

11 11/16"
(297 mm)

10 3/4"
(273 mm)

2 1/4"
(57 mm)

5 9/16"
(141 mm)

8 5/8"
(219 mm)

11 11/16"
(297 mm)

8 5/8"
(219 mm)

27 1/4"
(692 mm)

30 17/32" 8 15/16" 5"


(227 mm) (127 mm) (775 mm)

5"
(127 mm)

8 15/16"
(227 mm)

13 3/4"
(349 mm)

13 3/4"
(349 mm)

18 1/8"
(460 mm)

18 1/8"
(460 mm)

20 1/8"
(511 mm)

20 1/8"
(511 mm)

PENDANT MOUNT WITH GLOBE, GUARD AND REFLECTOR

WALL MOUNT WITH GLOBE, GUARD AND REFLECTOR

11 11/16"
(297 mm)

11 3/8"
(289 mm)

10 3/4"
(273 mm)

2 9/16"
(65 mm)

1"
(25 mm)

2 5/8"
(67 mm)

8 5/8"
(219 mm)

27 9/16"
(700 mm)

8 15/16" 5" 13 3/4"


(349 mm) (227 mm) (127 mm)

19 11/16"
(500 mm)

8 5/8"
(219 mm)

18 1/8"
(460 mm)

8 15/16"
(227 mm)

11 11/16"
(297 mm)

20 1/8"
(511 mm)

CEILING MOUNT WITH GLOBE, GUARD AND REFLECTOR

BULKHEAD MOUNT WITH GLOBE AND GUARD

78

Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB, IIA, Division 2, Groups A, B, C and D Class II Division 1 and 2, Groups E, F and G UL Listed (UL1598) for Marine Locations NEMA 4X, IP66

Hazlux 5 (400 Series) Dimensions

20 9/16"
(523 mm)

10 1/2"
(267 mm)

11 11/16"
(297 mm)

9 1/2"
(241 mm)

2 1/4"
(57 mm)

1 7/8"
(48 mm)

11 11/16" 8 5/8"
(219 mm) (297 mm)

8 5/8"
(219 mm)

18 / "
(460 mm)

3 32

25 3/8"
(645 mm)

25" 26 27/32"
(682 mm) (635 mm)

5" 14 1/2"
(368 mm) (127 mm)

8 15/16"
(227 mm)

13 3/4"
(349 mm)

18 1/8"
(460 mm)

PENDANT MOUNT WITH GLOBE AND GUARD

M3/3
20 1/8"
(511 mm)

STANCHION MOUNT WITH GLOBE, GUARD AND REFLECTOR

20 13/16" 10 / "
(273 mm)
3 4

(529 mm)

11 11/16"
(297 mm)

5 9/16"
(141 mm)

2 9/16"
(65 mm)

1"
(25 mm)

2 5/8" 11 11/16"
(297 mm)

8 5/8"
(219 mm)

8 5/8"
(219 mm)

(67 mm)

27 9/16"
(700 mm)

30 17/32"
(775 mm)

14 1/2" 5" 5" 13 3/4"


(349 mm) (368 mm)

14 1/2"

(127 mm) (368 mm)

13 3/4"
(349 mm)

(127 mm)

18 1/8" 18 1/8"
(460 mm) (460 mm)

20 1/8"
(511 mm)

20 1/8"
(511 mm)

WALL MOUNT WITH GLOBE, GUARD AND REFLECTOR

CEILING MOUNT WITH GLOBE, GUARD AND REFLECTOR

79

Hazlux M1 Certification Guide


LAMP TYPE 35 Watt H.P.S. Type S76 50 Watt H.P.S. Type S68 70 Watt H.P.S. Type S62 100 Watt H.P.S. Type S54 9 Watt Fluorescent 13 Watt Fluorescent 18 Watt Fluorescent 26 Watt Fluorescent Contact Factory AMBIENT C 40 55 65 40 55 65 40 55 40 40 40 40 40 MARINE LISTED (UL1598)* Yes Yes No Yes Yes No Yes Yes No Yes Yes Yes Yes ORDINARY LOCATIONS Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
CLASS I, ZONE 2, DIVISION 2 GLOBES TR REFRACTOR WITH/ WITHOUT REFLECTORS Temp. C Temp. Code

NEMA 4X, IP66


(Suitable for Hose-down)*

SUPPLY WIRE SUITABLE C 75 90 75 90 75 90 110 90 90 90 90

VOLTS 120 120 120 120 120 120 120 120 120 120 120 120 120

180 200 200 215 215 230 260 260 280 160 160 160 200

T3A T3 T3 T2D T2D T2C T2B T2B T2A T3C T3C T3C T3

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Hazlux 1 Certification Guide (40C Ambient)


LAMP TYPE High Pressure Sodium Metal Halide WATTS 50 70 100 150 70 100 175 AMBIENT TEMP C 40 40 40 40 40 40 40 CLASS I, ZONE 2, DIVISION 2 TEMPERATURE CODE
Globe*/Guard and Reflector Refractor*/ Guard

MARINE LISTED (UL1598)* Yes Yes Yes Yes Yes Yes Yes

NEMA 4X, IP66


(Suitable for Hose-down)*

ORDINARY LOCATIONS Yes Yes Yes Yes Yes Yes Yes

SUPPLY WIRE TEMP. RATING C 90 90 90 90 90 90 90

T3 T3 T3 T2C T3C T3 T2B

T3 T3 T3 T2C T3C T3 T2A

Yes Yes Yes Yes Yes Yes Yes

* NOTE REGARDING GLASS GLOBES AND REFRACTORS All Hazlux fixture assemblies shown in this Catalogue as CSA Certified are suitable for hose-down when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult Thomas & Betts Sales Office for more information.

80

Hazlux M3 Certification Guide (40C Ambient)


CLASS I, FIXTURE TYPE WATTS
Zone 2, Groups IIA, IIB, IIC DIVISION 2 Groups A, B, C, D TEMPERATURE CODE

CLASS II, DIVISION 1 & 2 GROUPS

CLASS III, DIVISION 1 & 2

NEMA 4X, IP66


(Suitable for Hose-down)*

Globe & Guard Globe & Guard Globe & Guard 8'' 8'' 8'' With or Without With or Without With or Without Refractor Refractor Refractor Reflector Reflector Reflector

MARINE LISTED (UL1598)*

High Pressure Sodium

35 50 70 100 150 70 100 9 13 18 26 60 100 150

T3A T3 T2B T2A T1 T2A T2A T3C T3C T3C T3C T3 T3 T2B

T3A T3 T2B T2A T1 T3C T3C T3C T3C T3 T3 T2B

EF&G EF&G EF&G E&F E&F E&F E&F EF&G EF&G EF&G EF&G E&F E&F

EF&G EF&G EF&G EF&G EF&G EF&G EF&G EF&G EF&G EF&G EF&G

Yes Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Metal Halide

Fluorescent

Incandescent

Certi cation Guide

* NOTE REGARDING GLASS GLOBES AND REFRACTORS All Hazlux fixture assemblies shown in this Catalogue as CSA Certified are suitable for hosedown when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult Thomas & Betts Sales Office for more information.

81

Hazlux 3 (Standard Housing) Certification Guide (40C Ambient)


LAMP TYPE AMBIENT WATTS TEMP (Deg. C) VGT/VGL22 5-1/2
Globe, Guard & Reflector T3C T3A T2C T2A T3C T3A T2A T2 50 70 100 150 70 100 175 250 40 40 40 40 40 40 40 40 CLASS I, Zone 2, Groups IIA, IIB, IIC DIVISION 2 Groups A, B, C, D TEMPERATURE CODE VRF22C5 12'' Dia. Refractor T4 T3C T2D T2B T2C T2 CLASS II DIVISION 1 & 2 GROUPS VGT/VGL22 5-1/2 Globe, Guard & Reflector EFG EFG EFG EFG EFG VRF22C5 12'' Dia. Refractor EFG EFG EFG EFG EFG EFG

UL1598 NEMA 4X, MARINE* IP66*

SUPPLY WIRE TEMP. RATING (Deg. C)


85 85 85 90 60 75 90 125

High Pressure Sodium Metal Halide

Yes Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes Yes

NOTES: - Simultaneous Presence Applications: Some Hazlux 3 fixtures are suitable for simultaneous presence of gas and dust. Contact Thomas & Betts Sales Office for specific information. - Tuffskin Coated Optics: Many Hazlux 3 fixtures are approved with Tuffskin (silicone) coating on glass optics. Contact Thomas & Betts Sales Office for specific information. - For CSA Certification Information on other ambient temperatures and fixture configurations, consult Thomas & Betts Sales Office.

Hazlux 3 (Refractor Globe Housing) Certification Guide (40C Ambient)


LAMP TYPE AMBIENT WATTS TEMP (Deg. C)
50 70 100 150 70 100 175 250 40 40 40 40 40 40 40 40 CLASS I, Zone 2, Groups IIA, IIB, IIC DIVISION 2 Groups A, B, C, D TEMPERATURE CODE VGL31R5 VGT31S 7-3/4 7-3/4 Dia. Globe, Guard Refractor Globe & Reflector T3C T3A T3 T2B T3C T3A T2B T2 T3C T3A T3 T2B T3C T3A T2B T2 CLASS II DIVISION 1 & 2 GROUPS VGT31S 7-3/4 Globe, Guard & Reflector EFG EFG EFG EFG EFG EFG EFG EF VGL31R5 7-3/4 Dia. Refractor Globe EFG EFG EFG EFG EFG EFG EFG EF

UL1598 NEMA 4X, MARINE* IP66*

SUPPLY WIRE TEMP. RATING (Deg. C)


60 85 85 90 60 75 90 90

High Pressure Sodium Metal Halide

Yes Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes Yes

NOTES: - Simultaneous Presence Applications: Some Hazlux 3 fixtures are suitable for simultaneous presence of gas and dust. Contact Thomas & Betts Sales Office for specific information. - Tuffskin Coated Optics: Many Hazlux 3 fixtures are approved with Tuffskin (silicone) coating on glass optics. Contact Thomas & Betts Sales Office for specific information. - For CSA Certification Information on other ambient temperatures and fixture configurations, consult Thomas & Betts Sales Office.

Hazlux 3 (Large Housing) Certification Guide (40C Ambient)


LAMP TYPE AMBIENT WATTS TEMP (Deg. C) VGT31 Globe
With Guard & Reflector T2 325C T2A T1 T2 350C 200 250 400 400** 250 400 40 40 40 40 40 40 CLASS I, Zone 2, Groups IIA, IIB, IIC DIVISION 2 Groups A, B, C, D TEMPERATURE CODE VRF31C5 12'' Dia. Refractor T2A 325C T2B T1 T2A 325C Reflector with Lens T2A 325C T2B T1 T2A 325C CLASS II DIVISION 1 & 2 GROUPS VGT31 Globe With Guard & Reflector EF EF VRF31C5 12'' Dia. Refractor EFG EFG EFG EFG EFG EFG Reflector with Lens EFG EFG EF EF EFG EF

SUPPLY WIRE UL1598 NEMA 4X, TEMP. MARINE* IP66* RATING (Deg. C)
Yes Yes Yes Yes Yes Yes Yes Yes 90 90 110 110 90 110

High Pressure Sodium HPS Metal Halide

NOTES: - 400 Watt HPS T-numbers based on BT/E/ED 37 diffuse coated lamp. Contact Thomas & Betts Sales Office for certification information when using other lamps. - Simultaneous Presence Applications: Some Hazlux 3 fixtures are suitable for simultaneous presence of gas and dust. Contact Hazlux for specific information. - Tuffskin Coated Optics: Many Hazlux 3 fixtures are approved with Tuffskin (silicone) coating on glass optics. Contact Thomas & Betts Sales Office for specific information. - For CSA Certification Information on other ambient temperatures and fixture configurations, consult Thomas & Betts Sales Office. ** 400 Watt HPS T-Numbers based on ED-18 diffuse coated lamp.

* NOTE REGARDING GLASS GLOBES AND REFRACTORS All Hazlux fixture assemblies shown in this Catalogue as CSA Certified are suitable for hosedown when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult Thomas & Betts Sales Office for more information.

82

Вам также может понравиться