Академический Документы
Профессиональный Документы
Культура Документы
06
Wgt.(kg) each Standard type (for most applications) Double-flange type (for deep concrete slab-layers) 6.92 10.52
CR320 includes additional plate to allow tape to be clamped without drilling. Nominal Rod Dia. inch 5/8 3/4 1 5/8 Hole Centre mm 37 37 37 37 Tape Width mm 25
* Suitable for use with 8mm solid circular copper conductor. Nominal Rod Dia. inch mm 5/8 3/4 16 20 Conductor Range mm 16-95 16-70 70-185 70-150
RWP Bond
Watermain Bond
* Clamps for copperbond rods are tapped to fit on threaded portion of rod. Nominal Rod Dia. inch mm 3/8 9.5 5/8 16 Rod Type Copperbond Copperbond* Solid Copper Copperbond* Solid Copper
6-5
06
Conductor mm 16 70 25 25
Channel Thickness mm 10 10 10 10
Earth Points
No. of M8 Holes 4 2 2 2
Front Plate Conductor No front plate 25x3mm or 70mm 25x3mm or 8mm dia. No front plate
Hole Size mm 11 11
Flexible copper braid for bonding gates, doors, fences, etc. equivalent cross sectional area 34.7 mm. Other material, lengths and section available as special items.
Where re-inforcing bars are electrically continuous and are to be used as down conductors, these earth points allow easy access for the lightning protection and earthing system.
Eyebolt
Type As PC110 with 0.5m long tail of 70mm PVC covered cable As PC115 with 0.5m long tail of 70mm PVC covered cable Nominal Copperbond Rod Dia. inches 5/8 3/4 Wgt. (kg) each 0.52 0.52 Cat. No. BT150 BT160
Made from LG2 gunmetal. Screws direct onto a copperbond earth rod, offering an earth point for boats, trucks, etc.
Length mm
Dia mm 50
Thread mm M10
Made from LG2 gunmetal for setting into roadways or runways. Provides a static discharge point for aircraft, fuel tankers, etc.
50
Made of mild steel to BS970 230M07 (ENIA) with phosphor bronze stud and nuts. For welding to steel vessels/tanks/ structures. Wrap connections with Denso Tape.
6-6
Puddle Flanges
Conductor Fixings
Recommended fixing-Round Head Woodscrew 15/8 x no 16 and wall plug.
06
DC Tape Clip
Type Disconnecting link Six way Earth Bar with Single Disconnecting Link Six way Earth Bar with Twin Disconnecting Link Six way Earth Bar Accessories Swan-Neck Link
Width mm 90 90 90 90
Height mm 90 96 96 90
Insulators
Thread Size With 2 Studs & Nuts Insulator only M10 M10 Cat. No. IN005 IN013
For
use
25 x 3 25 x 6 50 x 6
with
PVC
Covered
Recommended fixing - Round Head Woodscrew 15/8 x no. 16 and wall plug.
* Not as illustrated Air Rod Dia. mm 15 15 Thread Diamm 16 16 Wgt. (kg.) Rod Material each Copper Aluminium 0.23 0.08 Cat. No. CG600 CG500
For
use
with
PVC
Covered
0.01 0.01 CP025 CP030 CP035 CP040 CP045 CP050
25 x 3 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3
6-7
Tape Clip
Recommended fixing- Round Head Woodscrew 1 x no. 10 and wall plug. For use with Bare Copper
Conductor Size mm 20 x 3 25 x 3 Wgt. (kg) each 0.02 0.02 Cat. No. CP510 CP515
06
Weldable DC Clip
For use with PVC roofing only. Contact ADWAN for full details. For use with Bare Tape
Conductor Size mm 25 x 3 25 x 3 Wgt. (kg) per metre 0.03 0.03 Colour Brown Grey Cat. No. CW015 CW020
Block only supplied complete with fixing screw. Enables DC clips etc. to be secured to steel frames, girders, window frames, etc.
Slate Holdfast
For use with Bare Tape
Conductor Size mm 25 x 3 25 x 3 Wgt. (kg) each 0.06 0.06 DC Clip Colour Brown Grey Cat. No. HF015 HF020
CW905
0.62
CW999
Please note: Solvent cannot be supplied outside of the UK. For overseas projects, please contact ADWAN for advice.
Adhesive DC Clip
For use on surfaces other than PVC roofing Contact ADWAN for full details. For use with Bare Tape
Conductor Size mm 25 x 3 25 x 3 Wgt. (kg) each 0.03 0.03 Colour Brown Grey Cat. No. CA015 CA020 Conductor Material Copper Wgt. (kg) each 0.30 Cat. No. HF320
For use with appropriate DC Clip etc. Supplied with fixing screw.
6-8
Recommended fixing- Counter Sunk Woodscrew 1 x no. 10 and wall plug. Recommended fixing- Counter Sunk Woodscrew 1 x no. 10 and wall plug.
Max Conductor Conductor Material Size mm 26 x 12 Copper Cat. No. CT405 Conductor Dia. mm 8 10* Wgt. (kg) each 0.01 0.01 Colour Range Stone White CP876 CP881
Black CP861
06
Conductor Size mm 8 8 10* 10* Colour Grey Brown Grey Brown Wgt. (kg) each 0.03 0.03 0.03 0.03 Cat. No. CW872 CW887 CW871 CW886 * PVC covered 8mm conductor.
Bimetallic Connector
For joining aluminium to copper. Particularly useful where an aluminium lightning protection system needs to be earthed using copper.
CW905
0.62
CW999
Please note: Solvent cannot be supplied outside of the UK. For overseas projects, please contact ADWAN for advice.
Conductor Fixings
One Hole Cable Clip
For use on surface other than PVC roofing. Recommended fixingRound Head Woodscrew 1 x no. 10 and wall plug.
Conductor Dia. mm 8 8 10* 10* Conductor Material Copper Aluminium Copper Aluminium Wgt. (kg) each 0.01 0.01 0.01 0.01 Cat. No. CP905 CP925 CP915 CP935 Conductor Dia. mm 8 10* Wgt. (kg) each 0.02 0.02 Colour Range Stone White CA876 CA881
Black CA861
NOTE: Furse strongly recommended the use of the primer when installing the furse Adhesive Clip.
Conductor Dia. mm 8 8
Colour of Clip Wgt. (kg) each Cat. No. Brown Grey 0.03 0.03 HF176 HF191
Variation of tail length, clip size and clip colour can be made to order as special items.
6-9
Pyramid Holdfast
Supplied filled with concrete, they can be used to hold conductors on flat surfaces. The lip around the base allows them to be built into bitumen type roofs, etc. Suitable for 8mm dia. bare conductor.
Type Filled Wgt. (kg) each 0.97 Cat. No. HF975
Conductor Dia. 8mm Dia. Aluminium Conductor to 8mm Dia. Copper Conductor. 8mm Dia. Aluminium Conductor to 25 x 3 Copper Tape
0.19
CN920
06
Pipe Bond
Tee Clamp
Re-Bar Clamp
Jointing Clamp
Conductor Dia. mm 8 8
Test Clamp
For Straight Through Joints or for Disconnection and Test Purposes. Also suitable for connecting 8mm dia. conductor to 25 x 3mm conductor.
Conductor Dia. mm 8 8 Conductor Material Copper Aluminium Cat. No. CN305 CN310 8 8 10 10
Bimetallic Connector
Recommended fixingCounter Sunk Woodscrew 1 x no. 10 and wall plug. For joining aluminium and copper circular conductors particularly useful where an aluminium lightning protection system needs to be earthed using copper.
Rod Brackets
For wall mounted Air Terminals Recommended fixing- Counter Sunk Woodscrew 1 x no. 10 and wall plug.
Air Rod 15 15 Rod Copper Aluminiu Wgt. 0.90 0.28 Cat. BR105 BR005
6-10
Rod Brackets
Thread Dia. mm 16 16
Conductor Fixings
One Hole Cable Clip
Recommended fixing- Round Head Woodscrew 1 x no. 10 and wall plug.
Conductors Size mm 50 70 95 Conductor Material Copper Copper Copper Cat. No. CP910 CP915 CP920
MISCELLANEOUS EQUIPMENT
Type H -High Strength Split - Bolt Connector
06
DC Tape Clip
Compression Terminals
Stud mm 5 6 8 10 12 5 6 8 10 12 6 8 10 12 6 8 10 12 8 10 12 16 8 10 12 14 16 10 12 14 16
Cat. No. FCT16,5 FCT16,6 FCT16,8 FCT16,10 FCT16,12 FCT25,5 FCT25,6 FCT25,8 FCT25,10 FCT25,12 FCT35,6 FCT35,8 FCT35,10 FCT35,12 FCT50,6 FCT50,8 FCT50,10 FCT50,12 FCT70,8 FCT70,10 FCT70,12 FCT70,16 FCT95,8 FCT95,10 FCT95,12 FCT95,14 FCT95,16 FCT120,10 FCT120,12 FCT120,14 FCT120,16
6-11