Вы находитесь на странице: 1из 9

Zander Filter Systems, Inc. 5201-D Brook Hollow Pkwy. Norcross,GA.

30071
(770)446-3614 * Fax (770)263-0856 Toll Free 1-800-543-0851

ZAHDER@

1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11)

Expan8ion and Vent Chamber Air Vent Charcoal Filter (WT-CVP..) Conden8ate Inlet Inlet Balance Pipe First Separation Chamber Cleanable Dirt Filter Second Separation Chamber Water Activated Carbon Filter (WT-CMF.. Water OUtlet Adju8table Oil OUtlet Water Sample Valve

Description
1

of operation:

(Fiqure1..) with before

Waste condensate in a compressed air system is generally contaminated oil. This oil i. introduced by the air compressor and must be removed the conden8ate i8 di8charqed into a sewer.

Condensate drain lines from the system aftercoolers, filters, dryers and receivers may be piped directly into the inlet connection (3) of the Ecosep. As the condensate enters the Ecosep, any pressure i8 reduced to atmospheric pressure via the diffuser. The spray from this depressurization is captured by the CVF charcoal filter (2). At this point the oil/water mixture drains through the inlet tube as8embly (4) into the initial oil separation chamber

(5) .

3.

Within the initial oil separation chamber (5), the bulk of the oil rises to the surface and out into the .8condary settlinq chamber (7). The water is discharqed at the bottom of the initial oil separation chamber (5) to allow a flow of the cleanest conden.ate to enter the secondary separation chamber (7) at the bottom of the unit. The water then enter. the feeder pipe and throuqh displacement is caried into the first staqe activated charcoal chamber (8). The water flows down throuqh the activated charcoal filter which adsorb. any re.idual oil from the condensate and into the second staqe activated charcoal chamber via the transfer tube. Aqain throuqh displacement the condensate passe. throuqh a final polishinq filter and out the water discharge outlet (9). NOTE: The model WT 10 & WT 5 have only one activated charcoal filter (8). Throughout the process entrained Over a period of time a quantity build up on the surface until it and into an appropriate container oil is continuing to ri8e to the surface. of oil ( approximately 1/2" to 1" deep) will flow8 out of the oil di8charge assembly (10) (customer furnished) for proper disposal.

5.

For

convenience

there

is

a test

valve
so that

(11)

located
of is

at the
the

final

polishing
water can be ambient

f il ter taken
6.

(Not available for analysis.

on WT 5)

a sample heater

discharge for

An optional
operating

thermostatically
conditions.

controlled

available

low

- 1~Zawa~~~

Installation
Install the

of

the
in

Ecosep:
a frost free environment

Ecosep

Ensure the Ecosep is ins~alled in a stationary surface and ~ha~ the unit is completely level. If after ins~allation the Ecosep is bumped, shaken, subjected to vibration or not level, effective separation of ~he oil and water is significan~ly reduced. 3 Thoroughly wash the charcoal charcoal dust. Then ins~all Fill the discharge the unit. Ensure bottom at the Ecosep with clean (9). 8e sure oil filters with clean water to the filters in the appropriate water until adjustment separation the inlet it begins is as high remove ~he fine chambers. of the before water filling

to flow out as possible

that ~he initial oil of the unit and that top of chamber (5).

chamber (5) is fi~y tube assembly (4) is

seated to the snapped into place

Adjust the sleeve of the oil discharge assembly (10) so that the top of the sleeve is approximately 3/4" above the waterline. It will take some time after placing the unit in operation before a layer of oil builds up on the surface and begins to drain out of the separator. If during operation water is draining out of the oil discharge, raise the sleeve approximately an .ddtiona~ 1/4".
.

Connect the systeM condensate line of the separator utilizing or hose. Do Not Ina~l ~ Separator Using ~gid Pipe.

flexible

tubing

Connect both the water and oil discharge lines. The use of clear suggested for visual inspection purposes. The oil discharge line into a suitable container for disposal in accordance with local For optimum performance automatic self-regula~ing we recommend condensate the use of drain. Zander's

tubing is should drain regulations. a f~ly

Non

Ecodrain,

-.C:~..~~

ZAHDER@
Replacement Charcoal
separator

Filter
top.

Installation

Instructions:

1.

Remove the

2. Remove the old activated charcoal filters. disposed of in accordance with all local 3.
4.

The contaminated regulations. including


to remove

filters the removable


loose

should funnel

be

Thoroughly removing
Hose dust down fines.

all

clean the residue.


new

first separation chamber ( Fiqure 1, Item 5)


charcoal filter

the

activated

any

granules

and

5. Install

the

new activated

charcoal

filters

in the

appropriate

chamber.

(Figure

2)
6. Replace 7
.

the
filter the

separator
should vent filter

top

to

complete

the

installation.
the top any main and filters the are vent filter.

The vent
replaced.

be replaced lift thorouqhly filter off

each the to

time vent

8. 9. 10.

To change Clean Install the

remove

vent the

chamber new vent of the more

remove vent

residue. to complete by the is highly installation. separation emulsified

and replace

top

: The performance ; characteristics


:

and does

not

separate
o.il

of

the Ecosep is greatly compressor oil being used.

well,

then

the

activatedcharcoal

effected If the oil

charcoal
is

f.ilters

will

become
is

I saturated

with

rapidly.

Once the

saturated,

eff.ic.iency

reduced and the f il ter should be replaced. your separator we reccmmend that annually thoroughly cleaned. The Ecosep then should
. the
I

To mainta.in opt.imum performance from the un.it be completely emptied and be put back .in service by following
filters should be installed

at

init.ial this time

installation as well.

.instructions.

New charcoal

Replacement

Activated

Charcoal

Filters

~~~s-..~

Technical Docuaentation series WT oil/Water separator Models wr 5, wr 10, wr 20 & wr 30

ZAHDER@
Maintenance:
The Ecosep malfunctions oil. i~ a fully automatic Oil/Water Separation system. To avoid the following should be checked on a regular basis: possible

Ou't.l.e't.

After inLtial installation it will take weeks or months before the first amount of oil will be drained. Once the separator begins to discharge oil into the waste oil container be sure to inspect it for a mixture of oil and water. If this is the case, adjust the sleeve on the discharge port to a higher level.
'*

Con~roJ.

of

the

Drained

Wa~.r

An exact indication of the rest oil content can only be determined by a sample analysis from an independent laboratory. A sample can be taken via the sample valve on the separator. Regular sample analysis determines the condition of the activated charcoal filter and water quality. Zander provides a testing service for the Ecosep. Please contact your local Zander distributor for more information on this service. *

Replac...n~of

the Activa~ed

Charcoal

Pil~ers

The service life of the activated charcoal filter depends on the type of compressor, type of lubricating oil, amount of waste condensate, temperature of the waste condensate and the condensate discharge system. Normal loading conditions of compressor oil with good separation characteristics will render an average service life of about three to four months. It is recommended by the manufacturer to sample the water quality every ninety days at a minimum to ascertain the condition of the activated charcoal filters and ensure a consistant effluent quality from the separator.

Troubleshootinq: Malfunction
Liquid sprays out of inlet stack.

gause
Excessive compressed air at inlet of Ecosep

RemedY
Ensure that only auto drains are used, no manual ball valves. Timer drains should not exceed 4 seconds on time. Best solution-Ecodrain.
Make sure is properly re-adjust to higher change first filter and lubricant separation separator sized, oil sleeve level, stage check for quality.

Water & Oil coming out of oil discharge

I port.

Unit is overloaded, oil adjustment too low or first stage filter saturated.

Water

Discharge

is

cloudy.

Charcoal life depleted or waste condensate is highly emulsified.

- 4-

change charcoal filters, if discharge is still cloudy in a short period of time check lubricants separation quality.

~law:.~~~

ZAHDER@

s
Installation
1. 2. 3.

of Multiple

units:
however manifold it below is not should recommended be secured horizontally. to to use more than

Multiple units may be u8ed, three units per application. Piping to vibration. The main the illustrated block
"""'"

prevent

distribution

must

be installed

l ~~ "J:=~:1
-l

o-e..l:IC ,,)0 ":::.;OC

:-.-,.. .~""~.

~=*I

- 5\Cla18~~~

ZA..NDER(~
Ecosep Sizinq Guidelines' Dimensional Intor.ation:

1-.
Condensate

~
~
A

Inlets --

:'~~
~
I I

CkJIIICs

~Ie Vaiw

-,.The above values ..

oot ~pllcabl8

for POIygI~11ubfican18

-2. For Heavy Diester lubricants. reduce capacity by 35".. I"

-1
of

The actualdischargewaterquality may vary ~rding to the volumeof ~ndensat8 being processed. the ~ndition of the activatedchar=aI filters and the separationcharaderistics of the ~mpressor oil. The separatorperformancemay be enhancedby reducingthe volumeof ~ndensate beingintroducedinto the unit. replacement of the char=aI filters and/or~anging the compressor oil to a type with better separation qualities.

F EAT

RES

&

5 P EC

F CAT

0 NS

Features:
The ECOSEP Oil/Water Separato~with its activated charcoal filters, automatically separatesthe oil and water within the discharge condensate from compressed air systems.

. New seamless polyethylene


construction for greater durability

.
.

Built-in diffuser at inlet for effective

dispersion of compressed air . Removable first chamber with


sediment screen for easy cleaning
Zander One-Year Warranty on parts

.Removabletop for easy maintenance


. Sliding oil discharge port sleeve
for quick field adjustment

WT 20 & 30 feature two charcoal cham-

and workmanship

bers in series for cleaner discharge water

.Made in the U.S.A.

,- 'I

'1

Water Dimension

Model

A
WT10
WI 20

(Inches) B

Inlet Outlet Connection Connection


.t1L1;g,: rf1J!1::. (2) 1fl-

Oil Outlet Shipping Connection ~ght (Ibs.)


1~3/43/4-

I 35:50~I~I_l&:OO-' I 39,50' I 24.00' I 22.00' I

WT 30

I 51.50~r~l~

3/4' 3/4'-

45# 85# 100#

::~ ~

laBderFilterSystems, 1-.
5201-0 Brook HolIC1N Parkway Norcross. GA30071
Fax (404) 263-0856

ZANDER~ (404) 446-3614

1 (800) 543-0851
@1993 ZanderFilterS~ Inc. AI ~hts ReseMd.

I=~

c.- -4

ZAHDER@
Replacement Charcoal
separator

Filter
~op.

Installation

Instructions:

1. Remove

the

2. Remove the old activated charcoa.l fi.lters. disposed of in accordance with a.l.lloca.l
3. 4. Thoroughly removin~all clean the resiaue.

The contaminated regulations.


including to remove the any

fi.lters
removable loose

shou.ld

be

first separation chamber ( Figure 1, Item 5) charcoal charcoal filter filters

funnel ana

Hose down the

aust fines.
the

new activated

.,

granules

-.

5. Install 2)

new activated

in the

appropriate

chamber.

(Figure

6. Replace
7. 8. The vent replaced. To change

the
filter the

separator
should vent

top

to

complete

the

installation.
the top main and filters the are vent filter.

be replaced lift off

each the

time vent

filter

remove

9. Clean
10. Install

the

vent
the

chamber thorouqhly
filter

to

remove any residue.


vent top to complete installation.

new vent

and replace

The

performance

of

the

Ecosep

is

greatly

effected

by

the

separation

characteristics of the compressor oil being used. If the oil is highly emulsified 'and does not separate well, then the activated charcoal filters will become i saturated with oil more rapidly. Once the charcoal is saturated, efficiency is
:

.
!

reduced and the f il ter should be replaced. To maintain optimum performance from your separator we reccmmend that annually the unit be completely emptied and thoroughly cleaned. The Ecosep then should be put back in service by followL~g the initial installation instructions. New charcoal filters should be installed at this time as well.

Replacement Model Part Number


5

Activated

Charcoal

Filters
Quanti t~ Reauired 1 1
1. 1.

WT5
WT 10

WT -CVF

WT-CMF

(Vent) (Water (Vent) (Water

WT-CVF 10 WT-CMF 10

@~~=-rs~

Вам также может понравиться