SOLAR WATER HEATING

Item

Description BILL NO 1: SOLAR WATER HEATING SOLAR WATER HEATING EQUIPMENT AND ACCESSORIES Supply, installation, testing and commissioning of solar water heating equipment and accessories upon approval

Unit

Qty

Rate

AMOUNT

A.

of working drawings and manuals for the following:Solar Panel Solar panels shall be flat plate solar collectors. Solar Panel Construction:External: Glazing material shall be transparent and non-reflective to solar radiation. Total surface heating area of the solar panel shall be approx. 2.5m. The top of the panel shall be a single transparent glazed glass sheet. The glazed glass shall be of low-iron tempered glass or equivalent. The thickness of the glazed glass shall be 3 mm. The glazing and the holding construction shall have thermal characteristics to withstand extreme local temperatures and also thermal shock due to storms etc. Gasket for the glazing shall be EPDM gasket or similar. Absorber: Heat Exchanger: Copper tubes and fittings shall be utilized for internal panel pipe work and in accordance with B.S. 2871 or similar. All joints and connections between the riser and header tubings shall be leak proof and stand to hydraulic pressure tests. Insulation: The underside of the absorber, inclusive headers and the outer casing internal sides shall be insulated with 50 mm fibre glass insulation, minimum density 64 kg/m3. The insulation shall be non-combustible Supporting Frames Allow for suitable support of mild steel angle frame fixed on steel structure for the above solar panels to Engineers approval. The steel structure to be done by others. Pressure gauge Pressure gauge as manufactured by Honeywell to be fitted as instructed by the Engineer 4 No. 6,500 26,000.00 24 No. 55,000 1,320,000.00

B.

4 C.

No.

25,000

100,000.00

D.

Safety Valve Safety valve set to release when the water in the tanks exceeds 85oC as manufactured by "Spirax Sarco" model No. SV11 Pop type or equal and approved. Total Cost Carried Forward To Bill No.1 Collection Page 7
PAGE - 1

No.

9,000

36,000.00 1,482,000.00

SOLAR WATER HEATING

Item A.

Description 900 Litres Solar hot water storage cylinder The storage cylinder shall be high pressure fabricated from 5.0mm thick mild steel plate and hot dipped galvanised after manufacture, suitable for vertical mounting. The insulation shall be polyurethane foam 50mm thick injected in the void between outer wall of the storage tank and the outer casings. The outer casing shall be mild steel sheet 24 gauge finished in two coats gloss paint with a red oxide undercoat. The cylinder capacity and connections shall be as follows:Preferred dimensions: 2,450mm dia. x 1200mm high Capacity : 900 litres (196 gallons) Connections; 40mm diameter cold water supply feed 40mm diameter hot water outlet 40mm diameter water supply to solar panels 40mm dia. Hot water return from solar panels 25mm diameter drain 20mm diameter automatic air release valve 2No. heating elements of 3kW each

Unit

Qty

Rate

AMOUNT

No.

378,000

756,000.00

B.

Supporting frames Allow for suitable support of mild steel angle frame 300mm high above the floor slab to Engineers approval. 2 item 20,000 40,000.00 Electrical Heating Booster Elements 3KW, 240v 50hz heating element complete with thermostat mounted in the hot water cylinders complete with electrical wiring from local DB switches or isolators. 8 No. 3,500 28,000.00 Time Switch The auxiliary electric water heater elements shall be controlled by a time switch that they come 'ON' during peak hours only. The time switch must be capable of switching the heater 'ON' and 'OFF' at least two times per day. The time switch though electrically operated shall be capable of keeping time for a minimum 48 hours of electric power failure. Allow also for wiring from local isolators, to time switch/contactor and immersion heaters. Total Cost Carried Forward To Bill No.1 Collection Page 7
PAGE - 2

C.

D.

No.

22,500

90,000.00 914,000.00

SOLAR WATER HEATING

Item A.

Description Circulation Pumps:Circulation pumpset, one duty the other standby mounted on common mild steel base plate. Each pump to be capable of delivering 2.0m3/hr. against 8.0 metres head coupled with single phase, 0.46 Kw motor. The pumpset shall include all non-return valves, timer, isolating valves and pipe connections and to be as "Grundfos" hot water circulation pumps or approved equivalent. Temperature differential controls (Panels) The circulation pumps shall be controlled by temperature differential control unit as manufactured by 'fieldway ltd', with adjustable time delay circuit suitable for control of pump. The unit shall have a robust electric temperature sensing device for measuring temperature differences between two points. The sensing circuit of the unit should be stable over 5c to 50c temperature range. Allow for wiring from the service isolator to differential control to sensors in solar cylinder and pump. Control Panel The control and indication gear necessary for the solar heating installation shall be housed in a purpose made control panel. Each item of control and indication gear shall be clearly identified on the front cover. Allow for suitable delta connected contactors for heating elements power supply, overload controls and internal wiring.

Unit

Qty

Rate

AMOUNT

sets

75,000

75,000.00

B.

No.

25,000

50,000.00

E.

No.

45,000

90,000.00

A.

Dial Thermometer Dial Thermometer with 100mm diameter dial chart and graduated from 0c to 100c to be fitted to Engineer's approval. Automatic Air Eliminator Air relief valve as manufactured by "Spirax Sarco" model No. AES 50 Air Eliminators for use on hot water services. 4 Testing and Commissioning Allow for testing and commissioning of the domestic solar water heating equipment and accessories installation to the satisfaction of the Engineer. item No. 12,500 50,000.00

No.

7,500

15,000.00

B.

item

Sum

5,000.00

Total Cost Carried Forward To Bill No.1 Collection Page 7


PAGE - 3

70,000.00

SOLAR WATER HEATING

Item

Description SOLAR WATER HEATING PLUMBING Supply, deliver and install Chlorinated polyvinyl chloride (CPVC) pipes and fittings.The pipes shall be from an approved manufacturer. All pipes from 15mm to 50mm shall be as SDR 11 and shall meet the requirements of ASTM D2846.The pipesshall be able to withstand a maximum pressure of 28.1 bars. Pipes from 65mm to 300mm shall be schedule 40(SCH 40).They shall satisfy the requirements of ASTM F 441 and shall have pressure ratings between 9 bars and 59 bars. Rates must allow for all Metal/plastic threaded adaptors where required for the connection of sanitary fixtures, valves, sockets, plastic straps,metal straps, elbow holder, elbow holders, tee holders, end plugs, flanges, reducing couplers, caps, crosses, brass FPT tees, brass FPT elbows, sliding and fixed joints, support raceways, isolating sheaths, elastic materials, expansion arms and bends, crossovers, couplings, clippings, connectors, joints etc. as required in the running lengths of pipework and also where necessary, for pipe fixing clips, holder bats plugged and screwed for the proper and satisfactory functioning of the system. Piping

Unit

Qty

Rate

AMOUNT

A B C

25mm diameter ditto 32mm diameter ditto 40mm diameter ditto Extra Over piping for fittings:Elbows/bends

Lm Lm Lm

30 24 24

600.00 950.00 1,200.00

18,000.00 22,800.00 28,800.00

D E F

25mm diameter ditto 32mm diameter ditto 40mm diameter ditto Equal/Unequal Tees

No No No

24 6 4

250.00 280.00 300.00

6,000.00 1,680.00 1,200.00

G H I

25 x 25 x 25mm diameter ditto 32 x 32 x 25mm diameter ditto 40 x 40 x 25mm diameter ditto

No No No

12 12 12

250.00 300.00 350.00

3,000.00 3,600.00 4,200.00 89,280.00

Total Cost Carried Forward To Bill No.1 Collection Page 7

PAGE - 4

SOLAR WATER HEATING

Item

Description Male/Female Threaded Adaptors

Unit

Qty

Rate

AMOUNT

A B C

25mm diameter male/female threaded adaptors 32mm diameter ditto 40mm diameter ditto Gate valve

No No No

48 16 4

550.00 850.00 950.00

26,400.00 13,600.00 3,800.00

20mm diameter approved medium pressure screw down full way non- rising stem wedge gate valve to BS 1952, with wheel and head joints to steel tubing. The gate valve to be as Pegler or approved equivalent. 25mm diameter ditto 32mm diameter ditto 25mm diameter medium pressure ball valve Non-Return Valve

No No No No

24 4 4 2

1,800.00 2,800.00 3,500.00 3,200.00

43,200.00 11,200.00 14,000.00 6,400.00

E F G

20mm diameter non - return valve Safety / Pressure Release Valve

No

12

7,250.00

87,000.00

20mm pressure release valve

No.

12

10,500.00

126,000.00

Total Cost Carried Forward To Bill No.1 Collection Page 7

331,600.00

PAGE - 5

SOLAR WATER HEATING

Item Pipe Plug A B

Description

Unit

Qty

Rate

AMOUNT

40mm diameter pipe plug Solar header tank Supply, deliver and install rotationally moulded water plastic water storage tank . Tank Capacity : 2300 litres The tank to be complete with tank cover water level ball valve, Tank shall be complete with the following pipe connections. 40mm diameter overflow 40mm diameter outlet 32mm diameter inlet The tank shall be of approved manufacturer Hot Water Lagging Allow for lagging of hot water pipework using 25mm thick o industrial grade "Amaflex" insulation (85 C) as manufactured by Armstrong Cork. Allow for insulation & cladding fixing clips, rivets, holder bats plugged and screwed for the proper and satisfactory functioning of the system.

No

200

400.00

No.

35,000

70,000.00

C D

25mm diameter pipe insulation and cladding 40mm diameter ditto

Lm Lm

24 24

1,800.00 1,500.00

43,200.00 36,000.00

Total Cost Carried Forward To Bill No.1 Collection Page 7

149,600.00

PAGE - 6

SOLAR WATER HEATING

Collection Page for : Solar Water Heating Installation Item Description AMOUNT

Total from page 1

1,482,000.00

Total from page 2

914,000.00

Total from page 3

70,000.00

Total from page 4

89,280.00

Total from page 5

331,600.00

Total from page 6

149,600.00

Total Cost for Solar Water Heating System

2,886,880.00

PAGE - 7