4. 4.1.

MAIN INLET VALVE AND ACCESSORIES (SPHERICAL VALVE) Guaranteed Technical Particulars ITEM 1. 1.1 DESIGNATION General Manufacturer/ Type designation TBHydro Flovel Valves Pvt. Ltd./ SPV2P-M India IS7332/ Manufacturer Std.

UNITS

VALUE

REMARKS

1.2 1.3 2. 2.1

Place of Manufacturer Applicable standards Main data Maximum leakage from main valve when fully closed against maximum head of 250.2 m (with new seal) through service seal through maintenance seal Maximum leakage from bypass valve at maximum head of 250.20 meters Maximum head loss through the valve at a flow required for rated turbine output at rated net head Maximum torque required to close the valve with a flow corresponding to rated turbine output at rated net head specified turbine overload output at rated net head Rated turbine output at maximum net head of 182.20 m Rated turbine over load at maximum net head of 182.20 m.

L/min L/min L/min m

As per Std. As per Std. 0.040 0.01 mWc

2.2

2.3

N m N m N m

Later Later Later Later Later

Tender Document

2.4

Main dimensions of shut-off valve

Volume 3-C, Rev.1

Section 4 Sheet 1

Bidder Stamp and Signature

NAFRA HYDRO ELECTRIC PROJECT (2x60 MW)


Employer Consultant

SEW INFRASTRUCTURE LIMITED

SMEC INDIA PVT. LTD.

Tender Document

Volume 3-C, Rev.1 Bidder Stamp and Signature

Section 4 Sheet 2

NAFRA HYDRO ELECTRIC PROJECT (2x60 MW)


Employer Consultant

ITEM

SEW INFRASTRUCTURE LIMITED

DESIGNATION inside diameter length of valve body (excluding extensions) maximum distance from horizontal centreline of valve to lowest portion of assembly Lowest factor of safety (referred to design stress) for any hydraulically loaded part of the valve Valve operating oil pressure minimum maximum rated

UNITS mm mm mm

SMEC INDIA PVT. LTD.

VALUE

REMARKS

2200 3100 1800

2.5

1.5

2.6

Kg/cm Kg/cm Kg/cm

2 2 2

80 120 100 OPU is not in TFV Scope of Supply.

3. 3.1 3.2 3.3

Oil pressure unit(OPU) Number of main oil pumps Type of oil pumps Oil pump discharge capacity at pressure L/min Kg/cm kW 2

Nos. -

3.4 3.5 4. 4.1 4.2 4.3

Power rating of main pump motor Type of pressure switches Pressurised accumulator tank Total oil volume Design pressure Minimum possible operating cycles of shut-off valve(close-open) without recharging tank

L Kg/cm Hz
2

Tender Document

Volume 3-C, Rev.1 Bidder Stamp and Signature

Section 4 Sheet 3

NAFRA HYDRO ELECTRIC PROJECT (2x60 MW)


Employer Consultant

SEW INFRASTRUCTURE LIMITED

SMEC INDIA PVT. LTD.

ITEM DESIGNATION 4.4 Dimension of tank (Height X Dia.) 5. Sump tank 5.1 5.2 6. 6.1 Total oil volume Size of sump (L X W X Depth) Hydraulic oil Total quantity of Hydraulic oil required for complete system including servomotor Oil quantity

UNITS VALUE mm X mm L mm X mm X mm

REMARKS

6.2 4.2.

Informative data ITEM DESIGNATION 1. Servomotor 1.1 1.2 1.3 2. Make Nominal Design Pressure Active volume Guaranteed closing time of MIV at rated load and rated head of 176.47 m Guaranteed closing time of MIV at overload of (110%) and maximum head of 182.20 m Guaranteed maximum opening time at rated head of 176.47 m Guaranteed maximum opening time at maximum head of 176.47 m 3. Weights IPH/Equivalent kg/cm2 100 m3 Sec Sec Sec Sec 0.2 60-90 (adjustable) 60-90 (adjustable) 60-90 (adjustable) 60-90 (adjustable) UNITS VALUE REMARKS

Tender Document

Volume 3-C, Rev.1 Bidder Stamp and Signature

Section 4 Sheet 4

ITEM DESIGNATION 3.1 3.2 3.3 Weight of complete shut off valve Estimated shipping weight of valve Weight of complete oil pressure unit with pump set equivalent 3.4 4. 5. Maximum weight of valve assembly to be handled by power house crane Head loss through the valve at a flow required for rated turbine output Minimum floor opening required for valve installation/removal (L x W)

UNITS VALUE kg kg kg

REMARKS

85000(exclu. Counter wt.) 92000 not in TFV Scope of supply 85000 0.01 3100 x 7100

kg m mm mm

4.3.

Recommended additional spare parts List hereunder the spare parts which are recommended by the Bidder for purchase in addition to the specified spare parts. The purchase of any or all of the recommended spare parts will be at the option of Employer. The prices for recommended additional spare parts for five (5) years. ITEM 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. DESCRIPTION UNIT PRICE/ UNIT

12. 13. 14. 15. 16. 17. 18. 19. Note: Use additional sheet if required 4.4. Information to be supplied together with the bid At least the information listed hereunder shall be given by the Bidder. The Bidder may support advantages in his design of the delivery or special technical features of his offer by additional documents / descriptions 1. Indicate type of construction (cast steel or welded steel) for valve body and rotor 2. Describe method of operation on closure of the valve (by oil pressure and counter weight) 3. Specify proposed type of by-pass valve. 4. Describe method of operation of the automatic air inlet and vacuum release valve 5. Specify proposed type of service seal control valve. 6. Provide dimensional drawing with cross section showing the type of trunion seal, bearing, General Arrangement of major valve parts and main dimensions 7. Provide schematic and block diagram of complete shut-off valve system 8. Indicate expected maximum dynamic and static loads on foundation for the most unfavourable conditions (opening/closure) 9. Provide information on field performance tests performed on a shut-off valve, which is similar to the proposed valve. Indicate at least the following: place of field test year of field test size of valve design pressure