Вы находитесь на странице: 1из 67

Enlighten Home Inspections, LLC

Client

Inspection Report
Sample Client
Property Address: Sample Street Sample Report VA

Enlighten Home Inspections, LLC


Isaac Kieffer 39 Benton Court Sterling, VA 20165 IsaacKieffer@gmail.com (301) 204-2825

Sample Street

Page 1 of 67

Enlighten Home Inspections, LLC

Client

Table of Contents
Cover Page Table of Contents Intro Page 1 STRUCTURE 2 EXTERIOR 3 PLUMBING 4(A) ELECTRIC - GARAGE/EXTERIOR 4(B) ELECTRIC - UTILITY ROOM/INTERIOR 5(A) HVAC - UPPER LEVEL 5(B) HVAC - BASEMENT 6 INTERIOR 7(A) KITCHEN - BASEMENT 7(B) KITCHEN - MAIN LEVEL Minor Discovery Summary MAJOR Discovery Summary General Summary

Sample Street

Page 2 of 67

Enlighten Home Inspections, LLC

Client

Date: 4/30/2013 Property: Sample Street Sample Report VA

Time: 10:00 AM Customer: Sample Client

Report ID: SampleWebsite Real Estate Professional: Sample Agent Sample Realty

Enlighten Home Inspections, LLC is pleased to provide you with this home inspection report. This report is intended to provide you with an evaluation of the general condition of the home on the date of the inspection. Please read the entire report. The areas of the home that were inspected include: Structure, Exterior, Plumbing, Electric, HVAC (Heating, Ventilation and Air Conditioning), Interior and Kitchen. For condominiums and cooperatives, common areas are NOT inspected and are not part of a standard report. The structure and exterior are considered common areas in condominiums and cooperatives. The focus of the inspection was on major problems or concerns. A major problem or concern is a component that is significantly deficient and would potentially cost $500.00 to repair or replace, or posses a threat to life or health. These items, if any, are contained in this report and can be easily identified by locating an "X" in the "MA" (Major) column in each section of this report. Look for the description of the problem or concern in the corresponding explanation below the columns. Major problems or concerns can also be accessed by looking directly at the "MAJOR" Summary in this report. During the course of identifying major problems or concerns, it is nearly inevitable that minor problems or concerns will be located. A minor problem or concern is a component that is deficient and would more than likely cost less than $500.00 to repair or replace. Minor problems or concerns can be easily identified by locating an "X" in the "m" (minor) column in each section of this report. Look for the description of the problem or concern in the corresponding explanation below the columns. Minor problems or concerns can also be accessed by looking directly at the "MINOR SUMMARY" in this report. It is important to note that this inspection is not an all inclusive inspection and not every minor defect is noted in this report. It is my sincere hope that you find this report and our services to be beneficial. Thank you for choosing Enlighten Home Inspections, LLC for your home inspection needs. Regards, Isaac Kieffer Enlighten Home Inspections, LLC
Style of residence: Detached residence Radon Test: Yes Precipitation in the last 3 days: Yes - rain Occupied: No Client is present: Yes Weather: Partly cloudy Client attention: Complete Year Built: 1970 Temperature: 75 Others present: Buyer's agent, Family member(s)

Sample Street

Page 3 of 67

Enlighten Home Inspections, LLC

Client

1. STRUCTURE
Styles & Materials
STRUCTURE ACCESS: LIMITED BY: Finished basement VIEWED FROM: Exterior FOUNDATIONAL SETTLEMENT: DEGREE: Moderate MOISTURE CONTROL(S): Driveway drain Outside storm drain(s) Window well(s) FOUNDATION TYPE: Original construction Basement STRUCTURE TYPE: Original construction Solid masonry OTHER FACTORS: COMPLETE PEST INFESTATION/WOOD BORER INSPECTION RECOMMENDED PROBABILITY OF PAST DAMPNESS/SEEPAGE OR FLOODING: High PROBABILITY OF FUTURE DAMPNESS/SEEPAGE OR FLOODING: High - improvements needed Uneven floors Unable to determine if water intrusion will occur due to lack of heavy rain FOUNDATION MATERIALS: Concrete block/CMU (concrete masonry unit) FRAMING SETTLEMENT: DEGREE: Slight

IN
1.0 FOUNDATION WALLS 1.1 FLOOR SLAB 1.2 SEEPAGE/DAMPNESS 1.3 FRAMING 1.4 MASONRY WALLS 1.5 STRUCTURAL STEEL 1.6 CHIMNEY 1.7 FOR YOUR INFORMATION

NI MA m RR FYI

IN NI MA m RR FYI

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
1.0 Foundation settlement crack(s): Garage (Picture 1) - recommend contacting a licensed structural engineer to further evaluate 1.5 Rusted lintels: Multiple windows/doors (Pictures 1, 2) - keep lintels scraped and painted to prevent expansion
from rusting

1.7 For your information: Recommend installing a dehumidifier in the basement

Sample Street

Page 4 of 67

Enlighten Home Inspections, LLC

Client

2. EXTERIOR
Recommended that a licensed general contractor perform all repairs noted in this section.

Styles & Materials


ACCESS: Typical MAIN ROOF: ROOF COVERING 2: ACCESS: Viewed from ground ROOF LOCATION: Carport ACCESS: Viewed from roof edge ROOF INACCESSIBLE - Breakable roofing material LAYERS: 1 ROOFING MATERIAL: Slate AGE: 30+ years SLOPE: Moderate OVERALL CONDITION: Good PROBABILITY OF REPLACEMENT: Low TRIM MATERIAL: Wood

SITE/DRAINAGE: SIDING MATERIAL: GUTTERS: Aluminum Brick GUTTERS: Attached Stone COMPONENT: Downspouts COMPONENT: Underground drain(s) unable to inspect SURFACE CONTROLS: French drain SURFACE CONTROLS: Retaining wall(s) SURFACE CONTROLS: Window well(s) SITE: Above street level SITE: Ponding/wet areas SITE: Yard slopes toward house GRADING/DRAINAGE CONTROLS: Improvement(s) needed CHIMNEY: TYPE: Stone LOCATION: Gable LOCATION: Ridge GARAGE DOOR(S): Motorized door operator with release and auto reverse/stop ATTACHMENTS: Bay window Carport Patio Porch OTHER FEATURES: Fencing Large tree(s) Water feature - not inspected

DRIVEWAY: Asphalt

Sample Street

Page 5 of 67

Enlighten Home Inspections, LLC


IN
2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 ROOF COVERING ROOF DRAINAGE ROOF FLASHING SIDING TRIM MASONRY CHIMNEY(S) EXTERIOR DOOR(S) SAFETY RAILS STEPS/STAIRS

Client
NI MA m RR FYI IN NI MA m RR FYI

2.10 DRIVEWAY 2.11 GARAGE DOOR(S) 2.12 WALKWAY(S) 2.13 PATIO 2.14 LANDSCAPING 2.15 EXTERIOR DRAINAGE 2.16 DRIVEWAY DRAIN 2.17 RETAINING WALL(S) 2.18 WINDOW WELL(S) 2.19 FENCE(S) 2.20 FOR YOUR INFORMATION

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
2.0 MONETARY CONCERN: Damaged/missing/aged slate: Main roof back side (Pictures 1-5) - consult a licensed
roofing contractor

2.1 Improper drainage/damaged underground drain: Downspouts (Picture 1) - recommend extending downspouts a
minimum of 8-10 feet away from the foundation walls, further if possible. Use smooth wall pipe for extensions

2.3 Seal siding at penetration points: Multiple areas (Pictures 1, 2) - recommend sealing all siding penetrations with
duct seal

2.5 Eroded/cracked/missing mortar: Multiple areas (Pictures 1-16) - point up 2.6 (1) Missing flue cap and screen: Left chimney (Picture 1), Rear patio fireplace (Picture 2) 2.6 (2) Cracked crown: Right chimney (Picture 3)

Sample Street

Page 6 of 67

Enlighten Home Inspections, LLC


2.7 SAFETY CONCERN: Double cylinder deadbolt: Basement (Picture 1), Front door (Picture 2) - recommend
replacing with a deadbolt that is operable from the interior without a key

Client

2.8 (1) SAFETY CONCERN - Missing hand rail: Front left stairs (Picture 1), Right side (Picture 2), Backyard (Picture 3) - handrails should be continuous along the entire length of the stairs 2.8 (2) SAFETY CONCERN - Loose hand/safety rail: Left side stairs (Picture 4) 2.14 MONETARY CONCERN - Large tree(s) overhanging: Multiple trees (Picture 1) - keep branches trimmed away from roof and house 2.15 Ponding/wet areas: Front (Picture 1) - maintain a positive flow of surface water away from foundation walls 2.16 Clogged/debris: Driveway drain (Picture 1) - snake 2.17 SAFETY CONCERN - Retaining walls bowed/pulling away from the house: Back left side (Pictures 1, 2) monitor 2.20 For your information: Clean debris from window well(s) to allow water to drain quickly (Picture 1)

Sample Street

Page 7 of 67

Enlighten Home Inspections, LLC

Client

3. PLUMBING
Recommended that a licensed plumber perform plumbing repairs noted in this section.

Styles & Materials


SYSTEM ACCESS: Typical WATER SUPPLY: SUPPLY: Public MAIN SHUT OFF LOCATION: Utility room SERVICE ENTRANCE: Copper INTERIOR SERVICE: Copper INTERIOR SERVICE: Galvanized HOSE BIBBS: Freeze vulnerable HOSE BIBBS: Standard BATH WALLS: STYLE: Tile WASTE DISPOSAL: SYSTEM: Public WASTE LINES: Copper WASTE LINES: Galvanized WASTE LINES: Plastic

WATER HEATER: SIZE: 74.5 gallons FUEL: Gas AGE: 14 years - high probability of replacement COMPONENT: Metal flue OTHER FEATURES: Bath fan

GAS SUPPLY: SUPPLY: Street MAIN SHUTOFF: At gas meter

IN
3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 WATER HEATER TOILET(S) DRAIN(S) FAUCET(S) VALVE(S) DRAIN POP-UP FIXTURES BATHROOM TILE/WALL PROTECTION SHOWER DOOR/SURROUND PIPES AND FITTINGS

NI MA m RR FYI

IN NI MA m RR FYI

3.10 DRAIN/WASTE/VENT PIPES (DWV) 3.11 BATH VENT(S) 3.12 HOSE BIBB(S) 3.13 LOW WATER FLOW 3.14 GAS METER 3.15 GAS PIPE 3.16 FOR YOUR INFORMATION

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
3.2 (1) S trap: Basement bar sink (Picture 1), Upper level bathroom sink (Picture 2) - these traps tend to easily
siphon dry even when well-vented

3.2 (2) Drain leak(s): Entryway bathroom sink (Picture 3)

Sample Street

Page 8 of 67

Enlighten Home Inspections, LLC


3.2 (3) Clogged/slow drain: Jack and Jill bathroom bathtub (Picture 4), Upper level bathroom sink (Picture 5), Upper level bathroom bathtub (Picture 6) 3.3 Faucet leaks: Jack and Jill bathroom shower head (Picture 1), Upper level bathroom shower head (Picture 2)

Client

3.4 (1) Corroded valve(s): Utility room washer cold water line (Picture 1), Main level kitchen sink ice maker shut-off (Picture 2) 3.4 (2) Valves leak: Basement bathroom shower (Picture 3), Entryway bathroom sink cold water handle (Picture 4), Jack and Jill bathroom toilet (Picture 5) 3.4 (3) Hot and cold handles reversed: Basement bar sink (Picture 6) 3.5 Missing pop-up drain: Basement bathroom sink (Picture 1) 3.7 (1) Missing/cracked caulk: Bathtub(s)/shower(s) at the tile and floor (Picture 1) 3.7 (2) Cracked tiles: Basement bathroom (Pictures 2, 3) 3.7 (3) Cracked grout: Jack and Jill bathroom bathtub tiles (Picture 4) 3.9 For your information: Freeze vulnerable pipes - Rear hose bibb (Picture 1) 3.12 Vacuum breaker(s) missing - All hose bibbs (Picture 1) - can compromise public water supply safety 3.15 SAFETY CONCERN - Missing a gas shut-off valve outside of the fireplace: Rear patio (Picture 1), Basement (Picture 2) 3.16 (1) For your information: Recommend installing a washer pan with a drain 3.16 (2) For your information: Recommend installing No Burst or Flood Chek washer hoses 3.16 (3) For your information: Recommend installing a solid aluminum dryer vent instead of the foil vent (Picture 1)

Sample Street

Page 9 of 67

Enlighten Home Inspections, LLC

Client

4(A) . ELECTRIC - GARAGE/EXTERIOR


Recommended that a licensed electrician perform all electrical repairs noted in this section.

Styles & Materials


SYSTEM ACCESS: Typical SERVICE ENTRANCE CABLE: TYPE: Aluminum SERVICE: Underground AMPERAGE: 200 VOLTAGE: 120/240 PHASE: Single METER: Outside GROUNDING: Concealed PANEL: TYPE: Circuit breakers PANEL: Partially labeled EXPANSION ROOM: None SYSTEM: Trough LOCATION: Garage MAJOR CIRCUITS: Aluminum Copper Non metallic (NM) Armored cable (AC) GFCI LOCATION(S): Bath Exterior Kitchen RECOMMENDED: add at all wet locations

PANEL COVER CAPACITY: AMPERAGE: 200

GENERAL CIRCUITS: Copper Armored cable (AC)

RECEPTACLES: DISTRIBUTION: Typical TYPE: 3 prong

OTHER FEATURES: FIXTURES: Closet FIXTURES: Exterior FIXTURES: Recessed COMPONENT: Low voltage lighting

IN
4.0.A 4.1.A 4.2.A 4.3.A 4.4.A 4.5.A 4.6.A 4.7.A 4.8.A 4.9.A ELECTRIC PANEL SUB PANEL CIRCUIT BREAKERS CIRCUITS/CABLES SERVICE ENTRY CABLE (SEC) METER/METER BASE GROUND RECEPTACLES INSTALLATION/OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTER(S) SWITCHES/DIMMERS

NI MA m RR FYI

IN

4.10.A JUNCTION/WORK BOXES 4.11.A LIGHT FIXTURES 4.12.A CEILING FAN(S)

NI MA m RR FYI

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
4.0.A Improper cover screws: Electric panel (Picture 1) - pointed screws should never be used to secure the panel
cover

4.2.A SAFETY CONCERN - Overfused circuit(s): Electric panel (Picture 1)

Sample Street

Page 10 of 67

Enlighten Home Inspections, LLC


4.3.A (1) Missing conduit: Rear patio lighting cables (Picture 1) 4.3.A (2) Unprotected connections: Backyard (Picture 2) - all connections should be made in a covered junction
box

Client

4.3.A (3) Improper connections: Electric panel buss neutrals (Picture 1) - there should be no more than one neutral
per lug.

4.7.A Wall plate(s) missing: Garage (Picture 1) 4.8.A SAFETY CONCERN - Missing GFCI receptacle(s): Multiple exterior receptacles (Pictures 1-6) 4.10.A Missing cover plate(s): Garage junction box (Picture 1), Front door (Picture 2) 4.11.A Missing/burned bulb(s): Rear patio ceiling fan (Picture 1), Garage (Picture 2), Front door (Picture 3), Left
side (Picture 4)

4.12.A Unbalanced ceiling fan: Rear patio (Picture 1)

Sample Street

Page 11 of 67

Enlighten Home Inspections, LLC

Client

4(B) . ELECTRIC - UTILITY ROOM/INTERIOR


Recommended that a licensed electrician perform all electrical repairs noted in this section.

Styles & Materials


SYSTEM ACCESS: Typical SERVICE ENTRANCE CABLE: TYPE: Aluminum SERVICE: Underground AMPERAGE: 125 VOLTAGE: 120/240 PHASE: Single METER: Outside GROUNDING: Concealed PANEL: TYPE: Circuit breakers PANEL: Partially labeled EXPANSION ROOM: None SYSTEM: Expanded LOCATION: Utility room MAJOR CIRCUITS: Copper Non metallic (NM) Armored cable (AC)

PANEL COVER CAPACITY: AMPERAGE: 125

GENERAL CIRCUITS: Copper Non-metallic (NM)

IN
4.0.B 4.1.B 4.2.B 4.3.B 4.4.B 4.5.B 4.6.B 4.7.B 4.8.B 4.9.B ELECTRIC PANEL SUB PANEL CIRCUIT BREAKERS CIRCUITS/CABLES SERVICE ENTRY CABLE (SEC) METER/METER BASE GROUND RECEPTACLES INSTALLATION/OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTER(S) SWITCHES/DIMMERS

NI MA m RR FYI

IN NI MA m RR FYI

4.10.B JUNCTION/WORK BOXES 4.11.B LIGHT FIXTURES 4.12.B CEILING FAN(S) 4.13.B BATH FAN(S)

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
4.1.B (1) Improperly terminated cables: Utility room sub panel (Picture 1) 4.1.B (2) Loose panel cover: Utility room sub panel (Picture 2) 4.2.B SAFETY CONCERN - Overfused circuit(s): Electric panel (Picture 1) 4.3.B Missing wire clamp: Basement kitchen sink disposer feed wire (Picture 1)

Sample Street

Page 12 of 67

Enlighten Home Inspections, LLC


4.7.B (1) Wall plate(s) missing: Basement bathroom (Picture 1). Main level middle bedroom closet (Pictures 2, 3),
Master bedroom (Picture 4)

Client

4.7.B (2) Reversed polarity: Basement bathroom (Picture 5), Basement rear right room (Picture 6), Main level
kitchen (Picture 7), Main level office (Picture 8), Main level hall (Picture 9), Attic front bedroom (Picture 10)

4.7.B (3) Ungrounded electrical receptacles: Basement rear right room (Pictures 11, 12) 4.7.B (4) Loose receptacle(s): Main level kitchen (Picture 13) 4.8.B SAFETY CONCERN - Missing GFCI receptacle(s): Utility sink (Picture 1), Basement kitchen (Picture 2),
Basement bathroom (Picture 3), Basement bar (Pictures 4, 5), Main level kitchen (Picture 6), Entryway bathroom (Picture 7), Upper level bathroom (Picture 8)

4.9.B (1) Wall plate(s) missing: Utility room (Picture 1) 4.9.B (2) Defective dimmer: Basement safe room (Pictures 2, 3) 4.11.B (1) Unprotected closet fixture(s): Multiple closets (Picture 1) - recommend installing a fixture with a protective globe 4.11.B (2) Missing/burned bulb(s): Main level middle bedroom closet (Picture 2), Main level hall ceiling fixtures
(Picture 3)

4.12.B Inadequate clearance: Basement rear right room ceiling fan (Picture 1) - blades should be a minimum of 7'
from the ground

Sample Street

Page 13 of 67

Enlighten Home Inspections, LLC

Client

5(A) . HVAC - UPPER LEVEL


Recommended that a licensed HVAC technician perform all HVAC repairs noted in this section.

Styles & Materials


EQUIPMENT LOCATION: Attic AIR CONDITIONING: NOT TESTED: Temperature below 60 degrees within the last 24 hours RETROFITTED: Separate from heating system TYPE: Electric Compressor CAPACITY: 2.5 tons FORCED AIR: Down COMPONENT: Overflow pan with drain and switch DUCT SYSTEM: Metal CONDENSER AGE: 18 years - high probability of replacement

THERMOSTAT(S): Electronic Single - central CAUTION: Multiple systems simultaneous heat and AC operation possible

IN
5.0.A 5.1.A 5.2.A 5.3.A 5.4.A 5.5.A 5.6.A 5.7.A 5.8.A 5.9.A AIR HANDLER AIR CONDITIONER FILTER THERMOSTAT(S) AUTOMATIC SAFETY CONTROLS CONDENSATE DRAIN LINE(S) EMERGENCY DRAIN PAN DUCTWORK/PLENUM HEAT/COOL DISTRIBUTION AIR REGISTERS

NI MA m RR FYI

IN NI MA m RR FYI

5.10.A FOR YOUR INFORMATION

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
5.5.A Missing cap: Attic AC condensate drain line (Picture 1) 5.10.A For your information: Recommend contacting a licensed AC technician to service the unit once a year in the
spring

Sample Street

Page 14 of 67

Enlighten Home Inspections, LLC

Client

5(B) . HVAC - BASEMENT


Recommended that a licensed HVAC technician perform all HVAC repairs noted in this section.

Styles & Materials


EQUIPMENT LOCATION: Utility room HEATING CAPACITY: 245000 BTUs HEATING SYSTEM AGE: 10 years COMBUSTION GAS VENT/FLUE: TYPE: Metal HEATING - FUEL TYPE: Gas with electronic ignition AIR CONDITIONING: NOT TESTED: Temperature below 60 degrees within the last 24 hours RETROFITTED: Separate from heating system TYPE: Electric Compressor CAPACITY: 2.5 tons DUCT SYSTEM: Metal

CONDENSER AGE: 2 years

THERMOSTAT(S): Electronic Single - central CAUTION: Multiple systems simultaneous heat and AC operation possible

IN
5.0.B 5.1.B 5.2.B 5.3.B 5.4.B 5.5.B 5.6.B 5.7.B 5.8.B 5.9.B COMBUSTION AIR FLUE/COMBUSTION GAS VENT AIR HANDLER AIR CONDITIONER FILTER THERMOSTAT(S) AUTOMATIC SAFETY CONTROLS CONDENSATE PUMP CONDENSATE DRAIN LINE(S) DUCTWORK/PLENUM

NI MA m RR FYI

IN NI MA m RR FYI

5.10.B AIR REGISTERS 5.11.B REFRIGERANT LINES 5.12.B BOILER 5.13.B VALVE(S) 5.14.B BOILER PIPING 5.15.B PRESSURE RELIEF VALVE 5.16.B RADIATORS 5.17.B FOR YOUR INFORMATION

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
5.0.B Inadequate combustion air: Utility room (Picture 1) - recommend adding a louvered door

Sample Street

Page 15 of 67

Enlighten Home Inspections, LLC


5.1.B HEALTH CONCERN - Seal furnace and water heater flues at the thimble to prevent carbon monoxide from seeping into the house: Utility room (Pictures 1, 2) 5.4.B Dirty reusable HVAC filter: Utility room in the AC return plenum (Picture 1) - clean 5.8.B Missing cap: AC condensate drain line (Picture 1) 5.9.B Missing duct insulation: Garage (Picture 1) 5.17.B (1) For your information: Recommend contacting a licensed HVAC technician to service the heating and A/C units twice a year 5.17.B (2) For your information: Recommend cleaning the reusable HVAC filter every 30 days of operational use

Client

Sample Street

Page 16 of 67

Enlighten Home Inspections, LLC

Client

6. INTERIOR
Recommended that a licensed general contractor perform all repairs noted in this section.

Styles & Materials


SYSTEM ACCESS: LIMITED BY: Furnature/stored materials WALLS/CEILINGS: Plaster Wood paneling FLOOR COVERING: Carpet Ceramic tile Concrete Hardwood Parquet FIREPLACE(S): TYPE: Masonry COMPONENT: Damper

WINDOWS: TYPE: Casement TYPE: Fixed TYPE: Sliding MATERIAL: Steel MATERIAL: Vinyl GLAZING: Double GLAZING: Single INSULATION: ATTIC: Fiberglass loose R VALUE: 19 - upgrade recommended EXTERIOR WALLS: Not seen concealed by finished walls BASEMENT: None SMOKE ALARM(S): Present

DOORS: INTERIOR: Bi-fold INTERIOR: Hollow core EXTERIOR: Fiberglass (insulated) EXTERIOR: Solid wood SAFETY GLASS: No

ATTIC: STYLE: Partially finished ACCESS: Attic entered ACCESS: Attic traversed VENTILATION: Window(s) VENTILATION: Fan with thermostat OTHER SYSTEM INFORMATION: Ceiling paddle fan(s) Security system - not tested, outside the scope of a home inspection

MOISTURE/STAINS: LEAKAGE: Plumbing LEAKAGE: Roof - PRESENT?

IN
6.0 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 CEILINGS WALLS FLOORS TRIM DOORS (REPRESENTATIVE NUMBER) WINDOWS (REPRESENTATIVE NUMBER) FIREPLACE(S) ATTIC INSULATION ATTIC VENTILATION ATTIC MOISTURE

NI MA m RR FYI

IN NI MA m RR FYI

6.10 STEPS, STAIRWAYS, BALCONIES AND RAILINGS 6.11 SMOKE DETECTORS 6.12 COUNTERS, CABINETS AND SHELVES 6.13 FIRE SEPARATION 6.14 LEAD PAINT 6.15 FOR YOUR INFORMATION

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Sample Street

Page 17 of 67

Enlighten Home Inspections, LLC

Client

Comments:
6.4 Doors do not latch/doors rub/bind: Multiple doors (Pictures 1-3) - adjust hardware 6.9 Moisture stains: Attic (Pictures 1, 2), monitor 6.10 (1) SAFETY CONCERN - Missing hand rail: Entryway stairs (Picture 1) - handrails should be continuous
along the entire length of the stairs

6.10 (2) SAFETY CONCERN - Safety rails do not meet current child safety standards: Upper level stairs (Picture 2) - balusters should be spaced a maximum of 4" apart 6.11 SAFETY CONCERN - Inoperative smoke detector(s): Main level hall ceiling (Picture 1) - highly recommend
one smoke alarm in the general living space on each level, and one in each bedroom. Any smoke alarm ten or more years old needs to be replaced. If the age cannot be determined, it is best to replace the alarm(s)

6.13 Missing fire stop: Garage ceiling (Pictures 1, 2) 6.14 For your information: Any structure built prior to 1978 likely contains lead based paint 6.15 (1) For your information: Recommend contacting a licensed chimney sweep to clean and inspect the flues 6.15 (2) For your information: Recommend installing at least one carbon monoxide detector on every level and within ten feet of every bedroom

Sample Street

Page 18 of 67

Enlighten Home Inspections, LLC

Client

7(A) . KITCHEN - BASEMENT


Recommended that a licensed general contractor perform all repairs noted in this section.

Styles & Materials


SYSTEM ACCESS: Typical RANGE: FUEL: Electric AGE: 20-25 yrs CONDITION: Good REPLACEMENT PROBABILITY: Moderate (average life span = 15-20 yrs $650+) DISPOSER: AGE: 10-15 yrs CONDITION: Poor REPLACEMENT PROBABILITY: High (average life span = 5-12 yrs)

OTHER FEATURE(S): External discharge fan

IN
7.0.A RANGE 7.1.A DISPOSER 7.2.A SINK 7.3.A COUNTERTOPS/CABINETS 7.4.A DRAWERS/DOORS

NI MA m RR FYI

IN

NI MA m RR FYI

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
7.0.A (1) Inoperative oven light: Range (Picture 1) 7.0.A (2) SAFETY CONCERN - Anti-tip bracket not installed: Range (Picture 2) 7.1.A Seized: Basement kitchen sink disposer (Picture 1) 7.4.A Missing hardware: Basement kitchen cabinet doors and drawers (Picture 1)

Sample Street

Page 19 of 67

Enlighten Home Inspections, LLC

Client

7(B) . KITCHEN - MAIN LEVEL


Recommended that a licensed general contractor perform all repairs noted in this section.

Styles & Materials


SYSTEM ACCESS: Typical RANGE: AGE: 10-15 yrs CONDITION: Good REPLACEMENT PROBABILITY: Moderate (average life span = 15-20 yrs $650+) FEATURE: Convection oven FEATURE: Self cleaning oven REFRIGERATOR: AGE: 10-15 yrs CONDITION: Good REPLACEMENT PROBABILITY: Low (average life span = 15-20 yrs) FEATURE: Ice maker FEATURE: Ice dispenser FEATURE: Water dispenser MICROWAVE: AGE: 1-5 yrs CONDITION: Good REPLACEMENT PROBABILITY: Low (average life span = 5-10 yrs)

DISHWASHER: AGE: 10-15 yrs CONDITION: Good REPLACEMENT PROBABILITY: High (average life span = 5-12 yrs)

DISPOSER: AGE: 1-5 yrs CONDITION: Good REPLACEMENT PROBABILITY: Low (average life span = 5-12 yrs)

OTHER FEATURE(S): Recirculating fan

IN
7.0.B RANGE 7.1.B RECIRCULATING RANGE HOOD 7.2.B REFRIGERATOR 7.3.B DISHWASHER 7.4.B DISPOSER 7.5.B MICROWAVE 7.6.B SINK 7.7.B COUNTERTOPS/CABINETS 7.8.B DRAWERS/DOORS

NI MA m RR FYI

IN NI MA m RR FYI

IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information

Comments:
7.2.B Inoperative: Main level kitchen refrigerator ice maker (Picture 1) and water dispenser (Picture 2) - water line does not appear to be hooked up 7.3.B (1) Loose: Dishwasher (Picture 1) - recommend securing to the countertop or cabinet 7.3.B (2) Continues to cycle at the one minute point and does not automatically shut off: Dishwasher (Picture 2)

Sample Street

Page 20 of 67

Enlighten Home Inspections, LLC

Client

Minor Discovery Summary

Enlighten Home Inspections, LLC 39 Benton Court Sterling, VA 20165 IsaacKieffer@gmail.com (301) 204-2825 Customer Sample Client Address Sample Street Sample Report VA
The following items or discoveries indicate that these system(s) or component(s) do not function as intended, adversely affect the habitability of the dwelling, appear to warrant further investigation by a specialist, or require subsequent observation. Generally, this summary includes items that constitute "minor" problems or concerns. A minor problem or concern is an item or discovery that would cost less than $500.00 to repair or replace. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

1. STRUCTURE
1.5 STRUCTURAL STEEL Minor problem, Repair or Replace Rusted lintels: Multiple windows/doors (Pictures 1, 2) - keep lintels scraped and painted to prevent expansion from rusting

Sample Street

Page 21 of 67

Enlighten Home Inspections, LLC 1. STRUCTURE

Client

1.5 Picture 1

1.5 Picture 2

2. EXTERIOR
2.1 ROOF DRAINAGE Minor problem, Repair or Replace Improper drainage/damaged underground drain: Downspouts (Picture 1) - recommend extending downspouts a minimum of 8-10 feet away from the foundation walls, further if possible. Use smooth wall pipe for extensions

2.1 Picture 1 2.3 SIDING Minor problem, Repair or Replace Seal siding at penetration points: Multiple areas (Pictures 1, 2) - recommend sealing all siding penetrations with duct seal

Sample Street

Page 22 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR

Client

2.3 Picture 1 2.5 MASONRY Minor problem, Repair or Replace

2.3 Picture 2

Eroded/cracked/missing mortar: Multiple areas (Pictures 1-16) - point up

2.5 Picture 1

2.5 Picture 2

2.5 Picture 3

2.5 Picture 4

Sample Street

Page 23 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR

Client

2.5 Picture 5

2.5 Picture 6

2.5 Picture 7

2.5 Picture 8

2.5 Picture 9

2.5 Picture 10

Sample Street

Page 24 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR

Client

2.5 Picture 11

2.5 Picture 12

2.5 Picture 13

2.5 Picture 14

2.5 Picture 15 2.6 CHIMNEY(S) Minor problem, Repair or Replace

2.5 Picture 16

(1) Missing flue cap and screen: Left chimney (Picture 1), Rear patio fireplace (Picture 2)

Sample Street

Page 25 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR

Client

2.6 Picture 1 (2) Cracked crown: Right chimney (Picture 3)

2.6 Picture 2

2.6 Picture 3 2.15 EXTERIOR DRAINAGE Minor problem, Repair or Replace Ponding/wet areas: Front (Picture 1) - maintain a positive flow of surface water away from foundation walls

2.15 Picture 1

Sample Street

Page 26 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR


2.16 DRIVEWAY DRAIN Minor problem, Repair or Replace Clogged/debris: Driveway drain (Picture 1) - snake

Client

2.16 Picture 1

3. PLUMBING
3.2 DRAIN(S) Minor problem, Repair or Replace (1) S trap: Basement bar sink (Picture 1), Upper level bathroom sink (Picture 2) - these traps tend to easily siphon dry even when well-vented

3.2 Picture 1 (2) Drain leak(s): Entryway bathroom sink (Picture 3)

3.2 Picture 2

Sample Street

Page 27 of 67

Enlighten Home Inspections, LLC 3. PLUMBING

Client

3.2 Picture 3 (3) Clogged/slow drain: Jack and Jill bathroom bathtub (Picture 4), Upper level bathroom sink (Picture 5), Upper level bathroom bathtub (Picture 6)

3.2 Picture 4

3.2 Picture 5

3.2 Picture 6 3.3 FAUCET(S) Minor problem, Repair or Replace

Sample Street

Page 28 of 67

Enlighten Home Inspections, LLC 3. PLUMBING


Faucet leaks: Jack and Jill bathroom shower head (Picture 1), Upper level bathroom shower head (Picture 2)

Client

3.3 Picture 1 3.4 VALVE(S) Minor problem, Repair or Replace

3.3 Picture 2

(1) Corroded valve(s): Utility room washer cold water line (Picture 1), Main level kitchen sink ice maker shut-off (Picture 2)

3.4 Picture 1

3.4 Picture 2

(2) Valves leak: Basement bathroom shower (Picture 3), Entryway bathroom sink cold water handle (Picture 4), Jack and Jill bathroom toilet (Picture 5)

Sample Street

Page 29 of 67

Enlighten Home Inspections, LLC 3. PLUMBING

Client

3.4 Picture 3

3.4 Picture 4

3.4 Picture 5 (3) Hot and cold handles reversed: Basement bar sink (Picture 6)

3.4 Picture 6 3.5 DRAIN POP-UP Minor problem, Repair or Replace Missing pop-up drain: Basement bathroom sink (Picture 1)

Sample Street

Page 30 of 67

Enlighten Home Inspections, LLC 3. PLUMBING

Client

3.5 Picture 1 3.7 BATHROOM TILE/WALL PROTECTION Minor problem, Repair or Replace (1) Missing/cracked caulk: Bathtub(s)/shower(s) at the tile and floor (Picture 1)

3.7 Picture 1 (2) Cracked tiles: Basement bathroom (Pictures 2, 3)

3.7 Picture 2

3.7 Picture 3

Sample Street

Page 31 of 67

Enlighten Home Inspections, LLC 3. PLUMBING


(3) Cracked grout: Jack and Jill bathroom bathtub tiles (Picture 4)

Client

3.7 Picture 4 3.12 HOSE BIBB(S) Minor problem, Repair or Replace Vacuum breaker(s) missing - All hose bibbs (Picture 1) - can compromise public water supply safety

3.12 Picture 1

4(A). ELECTRIC - GARAGE/EXTERIOR


4.0.A ELECTRIC PANEL Minor problem, Repair or Replace Improper cover screws: Electric panel (Picture 1) - pointed screws should never be used to secure the panel cover

Sample Street

Page 32 of 67

Enlighten Home Inspections, LLC 4(A). ELECTRIC - GARAGE/EXTERIOR

Client

4.0.A Picture 1 4.3.A CIRCUITS/CABLES Minor problem, Repair or Replace (1) Missing conduit: Rear patio lighting cables (Picture 1)

4.3.A Picture 1 (2) Unprotected connections: Backyard (Picture 2) - all connections should be made in a covered junction box

4.3.A Picture 2

Sample Street

Page 33 of 67

Enlighten Home Inspections, LLC 4(A). ELECTRIC - GARAGE/EXTERIOR

Client

(3) Improper connections: Electric panel buss neutrals (Picture 1) - there should be no more than one neutral per lug.

4.3.A Picture 3 4.7.A RECEPTACLES Minor problem, Repair or Replace Wall plate(s) missing: Garage (Picture 1)

4.7.A Picture 1 4.10.A JUNCTION/WORK BOXES Minor problem, Repair or Replace Missing cover plate(s): Garage junction box (Picture 1), Front door (Picture 2)

Sample Street

Page 34 of 67

Enlighten Home Inspections, LLC 4(A). ELECTRIC - GARAGE/EXTERIOR

Client

4.10.A Picture 1 4.11.A LIGHT FIXTURES Minor problem, Repair or Replace

4.10.A Picture 2

Missing/burned bulb(s): Rear patio ceiling fan (Picture 1), Garage (Picture 2), Front door (Picture 3), Left side (Picture 4)

4.11.A Picture 1

4.11.A Picture 2

4.11.A Picture 3

4.11.A Picture 4

Sample Street

Page 35 of 67

Enlighten Home Inspections, LLC 4(A). ELECTRIC - GARAGE/EXTERIOR


4.12.A CEILING FAN(S) Minor problem, Repair or Replace Unbalanced ceiling fan: Rear patio (Picture 1)

Client

4.12.A Picture 1

4(B). ELECTRIC - UTILITY ROOM/INTERIOR


4.1.B SUB PANEL Minor problem, Repair or Replace (1) Improperly terminated cables: Utility room sub panel (Picture 1)

4.1.B Picture 1 (2) Loose panel cover: Utility room sub panel (Picture 2)

Sample Street

Page 36 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR

Client

4.1.B Picture 2 4.3.B CIRCUITS/CABLES Minor problem, Repair or Replace Missing wire clamp: Basement kitchen sink disposer feed wire (Picture 1)

4.3.B Picture 1 4.7.B RECEPTACLES Minor problem, Repair or Replace (1) Wall plate(s) missing: Basement bathroom (Picture 1). Main level middle bedroom closet (Pictures 2, 3), Master bedroom (Picture 4)

Sample Street

Page 37 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR

Client

4.7.B Picture 1

4.7.B Picture 2

4.7.B Picture 3

4.7.B Picture 4

(2) Reversed polarity: Basement bathroom (Picture 5), Basement rear right room (Picture 6), Main level kitchen (Picture 7), Main level office (Picture 8), Main level hall (Picture 9), Attic front bedroom (Picture 10)

Sample Street

Page 38 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR

Client

4.7.B Picture 5

4.7.B Picture 6

4.7.B Picture 7

4.7.B Picture 8

4.7.B Picture 9

4.7.B Picture 10

(3) Ungrounded electrical receptacles: Basement rear right room (Pictures 11, 12)

Sample Street

Page 39 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR

Client

4.7.B Picture 11 (4) Loose receptacle(s): Main level kitchen (Picture 13)

4.7.B Picture 12

4.7.B Picture 13 4.9.B SWITCHES/DIMMERS Minor problem, Repair or Replace (1) Wall plate(s) missing: Utility room (Picture 1)

4.9.B Picture 1

Sample Street

Page 40 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR


(2) Defective dimmer: Basement safe room (Pictures 2, 3)

Client

4.9.B Picture 2 4.11.B LIGHT FIXTURES Minor problem, Repair or Replace

4.9.B Picture 3

(1) Unprotected closet fixture(s): Multiple closets (Picture 1) - recommend installing a fixture with a protective globe

4.11.B Picture 1 (2) Missing/burned bulb(s): Main level middle bedroom closet (Picture 2), Main level hall ceiling fixtures (Picture 3)

Sample Street

Page 41 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR

Client

4.11.B Picture 2 4.12.B CEILING FAN(S) Minor problem, Repair or Replace

4.11.B Picture 3

Inadequate clearance: Basement rear right room ceiling fan (Picture 1) - blades should be a minimum of 7' from the ground

4.12.B Picture 1

5(A). HVAC - UPPER LEVEL


5.5.A CONDENSATE DRAIN LINE(S) Minor problem, Repair or Replace Missing cap: Attic AC condensate drain line (Picture 1)

Sample Street

Page 42 of 67

Enlighten Home Inspections, LLC 5(A). HVAC - UPPER LEVEL

Client

5.5.A Picture 1

5(B). HVAC - BASEMENT


5.0.B COMBUSTION AIR Minor problem, Repair or Replace Inadequate combustion air: Utility room (Picture 1) - recommend adding a louvered door

5.0.B Picture 1 5.4.B FILTER Minor problem, Repair or Replace Dirty reusable HVAC filter: Utility room in the AC return plenum (Picture 1) - clean

Sample Street

Page 43 of 67

Enlighten Home Inspections, LLC 5(B). HVAC - BASEMENT

Client

5.4.B Picture 1 5.8.B CONDENSATE DRAIN LINE(S) Minor problem, Repair or Replace Missing cap: AC condensate drain line (Picture 1)

5.8.B Picture 1 5.9.B DUCTWORK/PLENUM Minor problem, Repair or Replace Missing duct insulation: Garage (Picture 1)

Sample Street

Page 44 of 67

Enlighten Home Inspections, LLC 5(B). HVAC - BASEMENT

Client

5.9.B Picture 1

6. INTERIOR
6.4 DOORS (REPRESENTATIVE NUMBER) Minor problem, Repair or Replace Doors do not latch/doors rub/bind: Multiple doors (Pictures 1-3) - adjust hardware

Sample Street

Page 45 of 67

Enlighten Home Inspections, LLC 6. INTERIOR

Client

6.4 Picture 1

6.4 Picture 2

6.4 Picture 3 6.9 ATTIC MOISTURE Minor problem, Repair or Replace Moisture stains: Attic (Pictures 1, 2), monitor

6.9 Picture 1 6.13 FIRE SEPARATION

6.9 Picture 2

Sample Street

Page 46 of 67

Enlighten Home Inspections, LLC 6. INTERIOR


Minor problem, Repair or Replace Missing fire stop: Garage ceiling (Pictures 1, 2)

Client

6.13 Picture 1

6.13 Picture 2

7(A). KITCHEN - BASEMENT


7.0.A RANGE Major problem, Minor problem, Repair or Replace (1) Inoperative oven light: Range (Picture 1)

7.0.A Picture 1 7.1.A DISPOSER Minor problem, Repair or Replace Seized: Basement kitchen sink disposer (Picture 1)

Sample Street

Page 47 of 67

Enlighten Home Inspections, LLC 7(A). KITCHEN - BASEMENT

Client

7.1.A Picture 1 7.4.A DRAWERS/DOORS Minor problem, Repair or Replace Missing hardware: Basement kitchen cabinet doors and drawers (Picture 1)

7.4.A Picture 1

7(B). KITCHEN - MAIN LEVEL


7.2.B REFRIGERATOR Minor problem, Repair or Replace Inoperative: Main level kitchen refrigerator ice maker (Picture 1) and water dispenser (Picture 2) - water line does not appear to be hooked up

Sample Street

Page 48 of 67

Enlighten Home Inspections, LLC 7(B). KITCHEN - MAIN LEVEL

Client

7.2.B Picture 1 7.3.B DISHWASHER Minor problem, Repair or Replace

7.2.B Picture 2

(1) Loose: Dishwasher (Picture 1) - recommend securing to the countertop or cabinet

7.3.B Picture 1 (2) Continues to cycle at the one minute point and does not automatically shut off: Dishwasher (Picture 2)

7.3.B Picture 2

Sample Street

Page 49 of 67

Enlighten Home Inspections, LLC 7(B). KITCHEN - MAIN LEVEL

Client

Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Isaac Kieffer

Sample Street

Page 50 of 67

Enlighten Home Inspections, LLC

Client

MAJOR Discovery Summary

Enlighten Home Inspections, LLC 39 Benton Court Sterling, VA 20165 IsaacKieffer@gmail.com (301) 204-2825 Customer Sample Client Address Sample Street Sample Report VA
The following items or discoveries indicate that these system(s) or component(s) do not function as intended, adversely affect the habitability of the dwelling, appear to warrant further investigation by a specialist, or require subsequent observation. This summary includes those items that constitute "MAJOR" problems or concerns. A major problem or concern is any item or discovery that would cost more than $500.00 to repair or replace. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

1. STRUCTURE
1.0 FOUNDATION WALLS Major problem, Repair or Replace Foundation settlement crack(s): Garage (Picture 1) - recommend contacting a licensed structural engineer to further evaluate

Sample Street

Page 51 of 67

Enlighten Home Inspections, LLC 1. STRUCTURE

Client

1.0 Picture 1

2. EXTERIOR
2.0 ROOF COVERING Major problem, Repair or Replace MONETARY CONCERN: Damaged/missing/aged slate: Main roof back side (Pictures 1-5) - consult a licensed roofing contractor

Sample Street

Page 52 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR

Client

2.0 Picture 1

2.0 Picture 2

2.0 Picture 3

2.0 Picture 4

2.0 Picture 5 2.7 EXTERIOR DOOR(S) Major problem, Repair or Replace SAFETY CONCERN: Double cylinder deadbolt: Basement (Picture 1), Front door (Picture 2) - recommend replacing with a deadbolt that is operable from the interior without a key

Sample Street

Page 53 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR

Client

2.7 Picture 1 2.8 SAFETY RAILS Major problem, Repair or Replace

2.7 Picture 2

(1) SAFETY CONCERN - Missing hand rail: Front left stairs (Picture 1), Right side (Picture 2), Backyard (Picture 3) - handrails should be continuous along the entire length of the stairs

2.8 Picture 1

2.8 Picture 2

2.8 Picture 3

Sample Street

Page 54 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR


(2) SAFETY CONCERN - Loose hand/safety rail: Left side stairs (Picture 4)

Client

2.8 Picture 4 2.14 LANDSCAPING Major problem, Repair or Replace MONETARY CONCERN - Large tree(s) overhanging: Multiple trees (Picture 1) - keep branches trimmed away from roof and house

2.14 Picture 1 2.17 RETAINING WALL(S) Major problem, Repair or Replace SAFETY CONCERN - Retaining walls bowed/pulling away from the house: Back left side (Pictures 1, 2) - monitor

Sample Street

Page 55 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR

Client

2.17 Picture 1

2.17 Picture 2

3. PLUMBING
3.15 GAS PIPE Major problem, Repair or Replace SAFETY CONCERN - Missing a gas shut-off valve outside of the fireplace: Rear patio (Picture 1), Basement (Picture 2)

3.15 Picture 1

3.15 Picture 2

4(A). ELECTRIC - GARAGE/EXTERIOR


4.2.A CIRCUIT BREAKERS Major problem, Repair or Replace SAFETY CONCERN - Overfused circuit(s): Electric panel (Picture 1)

Sample Street

Page 56 of 67

Enlighten Home Inspections, LLC 4(A). ELECTRIC - GARAGE/EXTERIOR

Client

4.2.A Picture 1 4.8.A INSTALLATION/OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTER(S) Major problem, Repair or Replace SAFETY CONCERN - Missing GFCI receptacle(s): Multiple exterior receptacles (Pictures 1-6)

Sample Street

Page 57 of 67

Enlighten Home Inspections, LLC 4(A). ELECTRIC - GARAGE/EXTERIOR

Client

4.8.A Picture 1

4.8.A Picture 2

4.8.A Picture 3

4.8.A Picture 4

4.8.A Picture 5

4.8.A Picture 6

4(B). ELECTRIC - UTILITY ROOM/INTERIOR


4.2.B CIRCUIT BREAKERS Major problem, Repair or Replace

Sample Street

Page 58 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR


SAFETY CONCERN - Overfused circuit(s): Electric panel (Picture 1)

Client

4.2.B Picture 1 4.8.B INSTALLATION/OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTER(S) Major problem, Repair or Replace SAFETY CONCERN - Missing GFCI receptacle(s): Utility sink (Picture 1), Basement kitchen (Picture 2), Basement bathroom (Picture 3), Basement bar (Pictures 4, 5), Main level kitchen (Picture 6), Entryway bathroom (Picture 7), Upper level bathroom (Picture 8)

Sample Street

Page 59 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR

Client

4.8.B Picture 1

4.8.B Picture 2

4.8.B Picture 3

4.8.B Picture 4

Sample Street

Page 60 of 67

Enlighten Home Inspections, LLC 4(B). ELECTRIC - UTILITY ROOM/INTERIOR

Client

4.8.B Picture 5

4.8.B Picture 6

4.8.B Picture 7

4.8.B Picture 8

5(B). HVAC - BASEMENT


5.1.B FLUE/COMBUSTION GAS VENT Major problem, Repair or Replace HEALTH CONCERN - Seal furnace and water heater flues at the thimble to prevent carbon monoxide from seeping into the house: Utility room (Pictures 1, 2)

Sample Street

Page 61 of 67

Enlighten Home Inspections, LLC 5(B). HVAC - BASEMENT

Client

5.1.B Picture 1

5.1.B Picture 2

6. INTERIOR
6.10 STEPS, STAIRWAYS, BALCONIES AND RAILINGS Major problem, Repair or Replace (1) SAFETY CONCERN - Missing hand rail: Entryway stairs (Picture 1) - handrails should be continuous along the entire length of the stairs

6.10 Picture 1 (2) SAFETY CONCERN - Safety rails do not meet current child safety standards: Upper level stairs (Picture 2) balusters should be spaced a maximum of 4" apart

Sample Street

Page 62 of 67

Enlighten Home Inspections, LLC 6. INTERIOR

Client

6.10 Picture 2 6.11 SMOKE DETECTORS Major problem, Repair or Replace SAFETY CONCERN - Inoperative smoke detector(s): Main level hall ceiling (Picture 1) - highly recommend one smoke alarm in the general living space on each level, and one in each bedroom. Any smoke alarm ten or more years old needs to be replaced. If the age cannot be determined, it is best to replace the alarm(s)

6.11 Picture 1

7(A). KITCHEN - BASEMENT


7.0.A RANGE Major problem, Minor problem, Repair or Replace (2) SAFETY CONCERN - Anti-tip bracket not installed: Range (Picture 2)

Sample Street

Page 63 of 67

Enlighten Home Inspections, LLC 7(A). KITCHEN - BASEMENT

Client

7.0.A Picture 2

Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Isaac Kieffer

Sample Street

Page 64 of 67

Enlighten Home Inspections, LLC

Client

General Summary

Enlighten Home Inspections, LLC 39 Benton Court Sterling, VA 20165 IsaacKieffer@gmail.com (301) 204-2825 Customer Sample Client Address Sample Street Sample Report VA 1. STRUCTURE
1.7 FOR YOUR INFORMATION For Your Information For your information: Recommend installing a dehumidifier in the basement

2. EXTERIOR
2.20 FOR YOUR INFORMATION For Your Information For your information: Clean debris from window well(s) to allow water to drain quickly (Picture 1)

2.20 Picture 1

Sample Street

Page 65 of 67

Enlighten Home Inspections, LLC 2. EXTERIOR

Client

3. PLUMBING
3.9 PIPES AND FITTINGS For Your Information For your information: Freeze vulnerable pipes - Rear hose bibb (Picture 1)

3.9 Picture 1 3.16 FOR YOUR INFORMATION For Your Information (1) For your information: Recommend installing a washer pan with a drain (2) For your information: Recommend installing No Burst or Flood Chek washer hoses (3) For your information: Recommend installing a solid aluminum dryer vent instead of the foil vent (Picture 1)

3.16 Picture 1

5(A). HVAC - UPPER LEVEL


5.10.A FOR YOUR INFORMATION For Your Information

Sample Street

Page 66 of 67

Enlighten Home Inspections, LLC 5(A). HVAC - UPPER LEVEL


For your information: Recommend contacting a licensed AC technician to service the unit once a year in the spring

Client

5(B). HVAC - BASEMENT


5.17.B FOR YOUR INFORMATION For Your Information (1) For your information: Recommend contacting a licensed HVAC technician to service the heating and A/C units twice a year (2) For your information: Recommend cleaning the reusable HVAC filter every 30 days of operational use

6. INTERIOR
6.14 LEAD PAINT For Your Information For your information: Any structure built prior to 1978 likely contains lead based paint 6.15 FOR YOUR INFORMATION For Your Information (1) For your information: Recommend contacting a licensed chimney sweep to clean and inspect the flues (2) For your information: Recommend installing at least one carbon monoxide detector on every level and within ten feet of every bedroom

Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Isaac Kieffer

Sample Street

Page 67 of 67