Specifications -------------Radio Model Information Radio Model: TM8100 Band: B1 (136-174 MHz) Serial Number: 19693006 FCC Itinerant Channel Compliant: Yes Receiver Monitoring ------------------Receiver Monitoring Settings Monitor State at Power Up: Closed Monitor Reset on Network Change: No Squelch Settings Squelch Tail Extension Time: 50 Data ---Common Data Parameters Powerup State: Command Mode Command Mode Output Progress Messages: Yes Output All Selcall Receptions: No Output SDMs Automatically: No CCDI SDM Text Only: No Open Monitor On Dialled Call: Yes CCDI Mode Allowed: Yes Transparent Mode Transparent Mode Enabled: No Maximum Initial Frame Length: No Ignore Escape Sequence: No THSD Modem Enabled: No UART Write Delay: 0 Tx Back-off Time (Min): 0 Tx Back-off Time (Max): 0 Channel Access Method: Back-off Serial Communications Setup Command Mode Baud Rate: 19200 Flow Control: None FFSK Transparent Mode Baud Rate: 19200 Flow Control: None THSD Transparent Mode Baud Rate: 19200 Flow Control: None Data Port: Mic Software Flow Control XON Character: 11 XOFF Character: 13 Hardware Flow Control

CTS: None RTS: None FFSK Modem Ignore DCS/CTCSS: No Check Packet Length: Yes FFSK Tone Blanking: No FFSK Lead-In Delay: 500 FFSK Lead-Out Delay: 200 FFSK Baud Rate: 1200 THSD Modem Wide Band Modem Enabled: No Layer 2 Protocol: None Forward Error Correction (FEC): No Number of Blocks: 7 THSD Lead-In Delay: 30 THSD Lead-Out Delay: 0 All SDMs SDM Enabled: No Unit Data Identity: SDM Format: CCDI3 Only SDM Buffer Overwrite: No Text SDMs Only Indicate When SDM Received: No SDM Caller ID: No Transmit SDM Auto Acknowledgement: No SDM Auto Acknowledge Delay: 500 Receive SDM Auto Acknowledgement: No SDM Wait For Acknowledgement Time: 6 General GPS Position Reporting Enabled: No Connection Time Out: 20 Dispatcher Address: 00000000 Serial Communications GPS Port: Aux Baud Rate: 4800 RF Modems Poll Response Delay Time: 100 GPS Lead-In Delay: 500 Channel Setup Poll Response Channel Type: Current Channel: None Alarm Mode Callout Interval: 20 Maximum Number of Callouts: 5 Emergency Send Position on Emergency Callout: No Global Byte 4 : 0 Byte 3 : 0 Byte 2 : 0

Byte 1 : 0 Networks Network ID 1

Byte 1 0

Byte 2 0

Byte 3 0

Byte 4 0

Transparent Mode TOTAL Service: Unconfirmed Radio ID: 0000 System ID: 00 Destination ID: FFFF Link ID: 00 TOTAL MTU Size: 500 Confirmed Mode Retries: 3 Confirmed Mode Timeout: 500 Busy Response Back-Off Time: 2000 Selcall - Selcall Identity -------------------------Rx Format ID Tx Format

Rx Decode 1

Rx Decode 2

RMR Sequence

No records Selcall Sequence Formats Radio Unit Identity Sequences Selcall Options Selcall - Fixed Format Bursts ----------------------------Repeater Bursts Undefined Undefined Undefined Undefined Undefined Caller ID Bursts Undefined Undefined Lead-In Tones Undefined Undefined Undefined Undefined Undefined Tx Call Bursts Undefined Undefined Undefined Undefined Undefined Undefined

Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined

Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Repeater Access Tones Undefined Undefined Undefined Undefined Undefined Status Bursts Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Selcall - Free Format Bursts ---------------------------Sequences

Open Monitor

Selcall - Tone Settings ----------------------Parameters Custom Tone Set Tone Frequency Tone Frequency

Selcall - Control Status -----------------------Control Status Value No records DTMF - DTMF Signalling ---------------------Sequences

Control Status Type

Rx Processing

Channel Preset Sequence No records Tone Settings Two-Tone - Two-Tone Options --------------------------Standard Tone Set Tone A Tone B Tone C Tone D Custom Tone Set Tone A Tone B Tone C Tone D Tone Durations First Tone Gap Period Second Tone All Call Tone

MDC1200 - MDC1200 Options -------------------------

Parameters Presets Networks - Basic Settings ------------------------Basic Network Settings Network ID: 1 Signalling Type: None Signalling ID: None Selective Call Mute: No Squelch Detect Type: Noise Level Audible Side Tones: No Deferred Calling: No Deferred Calling Time: 0 Tx Duration Timing Tx Timer Duration: 60 Tx Lockout Duration: 0 PTT Inhibit Inhibit Mic PTT Outside a Call: No Inhibit EPTT1 Outside a Call: No Inhibit EPTT2 Outside a Call: No Subaudible Signalling Settings Validate When Selective Call Received: No Invalid Confirmation Delay: 20 Generate When Selective Call Transmitted: No Rx CTCSS/DCS Filter Enabled for: CTCSS/DCS CTCSS Settings Reverse Tone Burst Duration: 130 Reverse Tone Burst Phase Shift: 180 Lead-Out Delay: 0 DCS Settings Invert Tx DCS: No Invert Rx DCS: No Stop Tone Duration: 180 Lead-Out Delay: 0 Receiver Monitoring Settings Monitor on (Rx): Call Answered Monitor on (Tx): Call Initiated Hookswitch Monitor: No Hookswitch Monitor Overrides: All Mutes Monitor Overrides: All Mutes Auto Quiet Time: 30 Auto Quiet Timer Countdown: Reset SIBT Encode/Decode Settings SIBT Enabled: No Relationship to Signalling: Pre Signalling Frequency: 200 Encode Duration: 500 Lead-In Delay: 200 Lead-Out Delay: 50 Minimum Decode Duration: 200 CWID Enabled: No Wait Until End Of Transmission: No Sub-Audible Enabled: Yes Interval: 30

Words Per Minute: 20 Tone Frequency: 1000 String: MESSAGE Signal Processing Signalling Pre/De-emphasis: No Networks - Features ------------------Transmit Auto Acknowledge Auto Acknowledge Type: None Delay Before Sending: 500 Receive Auto Acknowledge Receive Acknowledgements: No Number of 'No Acknowledge' Retries: 0 Wait For Acknowledge: 6 Remote Monitor Reset Acknowledge When Received: No Alert When Received: No Call Clear: No Tone Blanking Enabled: No Deactivation Timer: 0 Tones to Receive Before Starting: 2 Networks - Phone Patch ---------------------Tone Settings Patch Sequence Tone Period: 50 Line Capture/Release Tone Period: 50 Phone Patch Intertone Gap Period: 50 Patch Intertone Tx Hold Time: 1000 Lead-In Delay: 500 Lead-Out Delay: 0 First Tone Period Multiplier: 1 Audible Phone Patch Side Tones: No DTMF Patch Settings Line Capture Sequence Sequence Sequence Sequence Line Release Sequence Sequence Sequence Sequence Patch Sequence Sequence Sequence Sequence Sequence

1: 2: 3: 4: 1: 2: 3: 4: 1: 2: 3: 4:

Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined

Networks - PTT Signalling ------------------------PTT Press

Signalling on PTT Press: None Suppress When Channel Busy: No Proceed To Talk Tone: No PTT Release Signalling on PTT Release: None Beep Frequency: 500 PTT Signalling Settings Include Signalling With Mic PTT: No Include Signalling With EPTT1: No Include Signalling With EPTT2: No ANI Suppression Time: 30 GPS Send Position on Mic PTT: None Send Position on EPTT1: None Send Position on EPTT2: None GPS PTT Suppression Time: 30 Networks - Emergency -------------------Activation Emergency Enabled: No Channel Type: Current Channel: None Tx on High Power: Yes Signalling Type: None Callout Callout Type: Disabled Number of Callouts: 1 Callout Repeat Interval: 10000 Emergency Cycling Emergency Cycling Type: Fixed Number of Cycles: 30 Rx Time: 10 Tx Time: 10 Emergency ANI: No Send SIBT on Tx Cycle: No Maximum Cycling Time: 600 Tone Options Over-the-Air Alert Tone: No Begin Tone Frequency: 30 Begin Tone Duration: 200 End Tone Frequency: 30 End Tone Duration: 200 Stealth Emergency Allow False Powerdown: Yes Action on Reset Call Received: Exit Emergency Mode Networks - Alerts ----------------Emergency Call Decode Alert/Ring Pattern: 11101110 Alert Type: Ring Internal Alert Duration: 30 External Alert: None External Alert Settings Alert 1

Delay: 30 Duration: 10 Mode: Pulse Alert 2 Delay: 30 Duration: 30 Mode: Steady Group Call Decode Alert/Ring Pattern: 10101010 Alert Type: Ring Internal Alert Duration: 30 External Alert: None Priority Call Decode Alert/Ring Pattern: 11111110 Alert Type: Ring Internal Alert Duration: 30 External Alert: None Auto Acknowledge: No Rx Decode Global Settings Rx Decode 1 Alert/Ring Pattern: 11011000 Alert Type: Ring Internal Alert Duration: 30 External Alert: None Auto Acknowledge: No Open Monitor: Yes Rx Decode 2 Alert/Ring Pattern: 11111000 Alert Type: Ring Internal Alert Duration: 30 External Alert: None Auto Acknowledge: No Open Monitor: Yes Super Group Call Decode Alert/Ring Pattern: 11011 Alert Type: Ring External Alert: None Channel Setup - Channels -----------------------ID Rx Tx Frequen Frequen cy cy 1 162,210 162,210 000 000 2 162,870 162,870 000 000 3 162,790 162,790 000 000 4 162,130 162,130 000 000 5 162,050 162,050 000 000 6 157,450 157,450 000 000 7 162,050 162,050 000 000

Rx Sig None None None None None None None

Tx Sig None None None None None None None

Power High High High High High High High

Network 1 1 1 1 1 1 1

Bandwid th 25 25 25 25 25 25 25

Squelch Country Country Country Country Country Country Country

8 9 10

163,250 000 162,810 000 158,270 000

163,250 000 162,810 000 158,270 000

None None None

None None None

High High High

1 1 1

25 25 25

Country Country Country

Channel Details Rx Frequency: 158,270000 Tx Frequency: 158,270000 Rx Sig: None Tx Sig: None Power: High Network: 1 Bandwidth: 25 Squelch: Country Channel Encrypted: No Tx Inhibit: None Noise Blanker: No Activate Birdie Killer: No Use Channel For Data: No Automatic Noise Reduction: No Companding: No Send/Decode SIBT on Channel: No Tone Settings Channel Repeater Access Tone: None Channel Lead-In Tone: None Channel Preset Call (Selcall) Repeater Burst Repeater Burst: None Caller ID Burst Caller ID Burst: None Tx Call Burst Tx Call Burst: None Status Status Burst: None Channel Preset Call (DTMF) Preset Sequence: None Selcall Decoding Rx Decode 1 Enabled: Yes Rx Decode 2 Enabled: Yes Group Call Decode: Yes Two Tone Two-Tone Individual Call Receive: Yes Two-Tone Group Call Receive: Yes Two-Tone Super Group Call Receive: Yes Channel Setup - Scan Groups --------------------------Group ID Group ID: 0 Group Type: Vote Group Hold Time: 5000 Transmit Group Hold Time: 8000 Allow Scan When Off Hook: No Scan Immediately When Placed on Hook: No

UI Preferences Hidden Channels: No Disable Deferred Calling: No Group Membership Channel ID 1 2 3 4 5 6 7 8 9 10 Vote Settings Revote After Transmission: No Validate Signalling While Voting: No Lead-in Delay: 60 Revote Interval: 60 Group Voting Display Indicator: Tx Channel Priority Scan Settings Priority Scan: Disabled Priority One Channel: 1 Dual Priority Scan: No Priority Two Channel: 1 Validate Signalling on Priority Channels: Yes Captured Channel Priority Sample Timer: 3000 Busy Priority Sample Timer: 3000 Non-Captured Channel Priority Sample Timer: 1500 Delete Priority Channels: No Scan Settings Scan Type: Standard Scan Group Display Indicator: Group ID Channel to Respond On: Captured Initiate Call Channel: Preset Preset Tx Channel: 1 Include Current Channel in Scan Regime: No Validate Signalling While Scanning: Yes Suspend Scan on PTT Release: No TaitAx Search Timer: 1 Captured Alert: No Search Indicator: No Key Settings -----------Function Key Actions Key 1: None Key 2: Monitor / Squelch Override Key 3: None Key 4: None Settings Setting 1 for Function Key Setting 1 for Function Key Setting 1 for Function Key Setting 1 for Function Key

1: 2: 3: 4:

0 0 0 0

-------------Preferences Backlight Mode: With Activity Backlight Duration: 5 Confidence Tones: Yes Confidence Tones Level: Low Audible Operation Level: Normal List Operation Wrap Around: Yes Mic: Normal Override VSWR Foldback Power: No Audible Indicators Initial Indicator Level: High Minimum Tone Volume Level: 32 Indicators Acknowledgement Computer Control Emergency Activated Emergency Cleared Down Emergency Failure End Of List Function Activated Function Deactivated High Temperature Warning Very High Temperature Warning Impending Transmit Timeout Out Of Lock Power Down Power Up Programming Mode Radio Revived Radio Stunned SDM Received System Error Test Mode Transmit Inhibit Channel Freed Radio Locked Radio Unlocked Digital Output Activated High Reverse Power Warning Tone

Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled

Audio Setup Enable Options Board Preamp: No Emergency Mic: Control Head Control Head Mic Gain: Normal Auxiliary Mic Gain: Normal Minimum Volume Level: 0 Encryption Inversion Frequency: 2850 Global Encryption: Yes Economy ------Economy Economy Timer: 10 Economy Duty Cycle: Medium Start-up -------Start-up Power On Mode: Power On Start in Economy Mode: No

Start in Low Power Mode: No Front Panel Low Power Control: Low Reset on Error: Yes Disable On/Off Control: No Channel/Group Active on Power Up: No ID: 1 Keypad Mic Mode: Channel Control Security PIN Security Security Security Security Lock PIN: PIN: PIN: on Power Up: No F1 F1 F1

PTT --PTT Call Initiation and Monitor PTT Press Call Setup: No De-key After PTT Call Setup: When Ack Expected PTT Monitor: Never De-key After PTT Monitor: Yes PTT Inhibit Inhibit PTT When Emergency Active: No Inhibit PTT Transmission When Mic on Hook: No Inhibit PTT When External PTT Inhibit Active: No Indicate PTT Inhibit to User: Yes Advanced PTT PTT Transmission Type: Voice PTT State is Reflected: No PTT Priority: Highest Audio Source: CH MIC PTT Deactivation Delay: 0 EPTT1 Call Initiation and Monitor PTT Press Call Setup: No De-key After PTT Call Setup: When Ack Expected PTT Monitor: Never De-key After PTT Monitor: Yes EPTT1 Inhibit Inhibit PTT When Emergency Active: No Inhibit PTT Transmission When Mic on Hook: No Inhibit PTT When External PTT Inhibit Active: No Indicate PTT Inhibit to User: Yes Advanced EPTT1 PTT Transmission Type: Voice PTT State is Reflected: No PTT Priority: Medium Audio Source: AUX MIC PTT Deactivation Delay: 0 EPTT2 Call Initiation and Monitor PTT Press Call Setup: No De-key After PTT Call Setup: When Ack Expected PTT Monitor: Never De-key After PTT Monitor: Yes EPTT2 Inhibit Inhibit PTT When Emergency Active: No Inhibit PTT Transmission When Mic on Hook: No Inhibit PTT When External PTT Inhibit Active: No Indicate PTT Inhibit to User: Yes

Advanced EPTT2 PTT Transmission Type: Voice PTT State is Reflected: No PTT Priority: Lowest Audio Source: AUX MIC PTT Deactivation Delay: 0 Programmable I/O ---------------Pin Directio n AUX_GPI1 None AUX_GPI2 AUX_GPI3 Input Input

Label PIN_12 PIN_5 2BSETUP

Action No Action Enter Emergenc y Mode Power Sense (Ignitio n) No Action No Action No Action No Action No Action No Action No Action No Action No Action No Action No Action No Action

Active None Low High

Debounce None 100 10

Signal State None None None

Mirrored To None None None

AUX_GPIO 4 AUX_GPIO 5 AUX_GPIO 6 AUX_GPIO 7 IOP_GPIO 1 IOP_GPIO 2 IOP_GPIO 3 IOP_GPIO 4 IOP_GPIO 5 IOP_GPIO 6 IOP_GPIO 7 CH_GPIO1

None None None None None None None None None None None None

PIN_10 PIN_2 PIN_9 PIN_1 PIN_9 PIN_10 PIN_11 PIN_12 PIN_13 PIN_14 PIN_15 C_HEAD

None None None None None None None None None None None None

None None None None None None None None None None None None

None None None None None None None None None None None None

None None None None None None None None None None None None

Digital I/O Settings Save I/O Output States: No Carrier Delay Time: 0 Action Parameters Emergency Mode: Stealth Mute Audio Input: Audio Tap In Mute Audio Output: Speaker Audio Path Home Channel: 1 Preset Channel: 1 Preset Group: 1 Unmute Audio Output: Speaker Audio Path Alarm on Stunned: No Alarm on Out of Lock: No Alarm on High Temperature: No Alarm on Very High Temperature: No Alarm on High Reverse Power: No Rx/PTT Type Tap In Tap In Type Tap In Unmute Tap Out Tap Out Type Tap Out Unmute Tap In Inverte d Tap Out Inverte d

Rx Mic PTT EPTT1 EPTT2

None None None None

A Bypass In A Bypass In A Bypass In A Bypass In

On PTT On PTT On PTT On PTT

None None None None

D Split C Bypass Out C Bypass Out C Bypass Out

On PTT On PTT On PTT On PTT

Disable d Disable d Disable d Disable d

Disable d Disable d Disable d Disable d

BCD BIN / BCD Operation: BIN BCD Channel Selection: Record Number Front Panel Channel Selection Lockout: None