Single-Phase Central Lighting Inverter 400 - 2100 VA/Watts

Features

DLS

AC output provides full lumen output for emergency lighting loads in commercial or industrial applications Compatible with any lighting load including incandescent, fluorescent, HID and LED lamps Painted steel enclosure Offline operation up to 98% efficient Maintenance-free lead-calcium batteries Factory startup standard Temperature range: 20C to 30C (68F to 86F) UL 924 Listed; Made in USA

i n v e rt e r s Ordering Information

DLS
Model DLS INPUT/OUTPUT VoltaGE 120 120VAC 277 277VAC OUTPUT Circuit BREAker Voltage Rating A 120VAC B 277VAC OUTPUT Circuit BREAker AMPERE Rating 15 15 Amperes 20 20 Amperes 25 25 Amperes 30 30 Amperes OUTPUT Circuit BREAker Quantity 01 1 circuit breaker 02 2 circuit breakers 03 3 circuit breakers 04 4 circuit breakers 05 5 circuit breakers 06 6 circuit breakers 07 7 circuit breakers 08 8 circuit breakers 09 9 circuit breakers 10 10 circuit breakers

CAPACITY Rating1 400 400 VA/Watts 525 525 VA/Watts 750 750 VA/Watts 1000 1000 VA/Watts 1500 1500 VA/Watts 2100 2100 VA/Watts
1

OUTPUT Circuit Breaker Type


Blank N

Normally-On Normally-Off2

Output Circuit Breakers: 400 VA and 525 VA models are supplied with one, 15 amp normally on circuit breaker 750 VA through 2100 VA models: output circuit breakers are optional

2 A maximum of 4, normallyoff circuit breakers may be specified. Maximum rating of normally-off circuit breakers is 20 amperes. Normally-off circuit breakers include a built-in, 15-minute retransfer delay to accomodate HID lighting loads

OUTPUT Circuit BREAker SUPERVISION Blank Monitored U Unmonitored3


3

A maximum of 6 monitored or 10 unmonitored normally on circuit breakers may be specified

Electronics

Uninterruptible no break transfer Microprocessor controlled pulse width modulation (PWM) using IGBT technology LVD, short-circuit, current limiting and overload protection True sine wave output Power factor range of 0.8 lead to 0.75 lag LED status indicator, audible alarm system and push button test switch

988


specifications Features
VA/Watts

Single-Phase Central Lighting Inverter 400 - 2100 VA/Watts


400 525 750 1000 1500 2100

DLS

Input/Output Voltage AC Input Circuit Breaker Rating 120/277V AC Output Circuit Breaker Rating Charger Size System DC Voltage System DC Control Cabinet Size BTU/Hour - Line/Inverter Weight [lbs. (kg) - including batteries] 22W x 23H x 10D (55.9cmW x 58.4cmH x 25.4cmD) 70/260 143 (65.1) 92/341 173 (78.8) 36 36 10/15 Amps Single Pole, 15 Amp, Normally-On

120/120 or 277/277VAC 10% 15/15A 2 Amps 72 72 72 96 DC Switch, DC Fuse 32W x 36.5H x 12D (81.3cmW x 92.7cmH x 30.5cmD) 131/382 281 (128) 175/510 346 (157.6) 263/765 400 (182.2) 368/886 480 (218.7) 20/15A 25/15A

i n v e rt e r s

Optional: Single Pole, Normally-On, Normally-off

750VA to 2100VA Models (floor mount only)

400VA to 525VA Models (may be wall mounted)

989

Service Options
Service Options for Single Phase Inverters

Factory Startup
All single-phase inverter systems (except LiteGear models) are provided standard with factory start-up service by a qualified technician and a two year warranty. A factory trained technician will perform all steps necessary to insure proper operation of the central lighting inverter following installation by a qualified electrical contractor.

Monitoring Program
For additional peace of mind (charge required), an inquiry will be sent to the single-phase inverter system each month and the results will be reviewed by Dual-Lites Technical Support Department. The results of the review will be sent to the designated customer contact with recommendations for corrective action.
S e rv i c e O p t i o n s

Additional Training Visit


After completing the on-site system start-up, the technician will be available at that time to train owner/user personnel. If the appropriate personnel are not available for on-site training at the completion of the factory start-up procedure, an Additional Training Visit (ATV) option is available at extra cost.

Preventive Maintenance Program


All single-phase inverter systems (except LiteGear models) qualify for Dual-Lites preventive maintenance program. This program provides nine different plan levels including extended warranty programs (refer to the below eplaination of plan levels for more information). Each plan offers a choice of preventive maintenance levels that provide annual visits by a factory trained technician plus call for service options.

PMP-A1 Additional 1-year warranty and 1-year service coverage, weekdays, M-F, 8AM to 5PM EST. PMP-B1 Additional 1-year warranty and 1-year service coverage, 24 hours/ day, 7 day/week (no holidays). PMP-C1 Additional 1-year warranty and 1-year service coverage, 24 hours/ day, 7 day/week (includes holidays).

PMP-A2 Additional 2-year warranty and 2-year service coverage, weekdays, M-F, 8AM to 5PM EST. PMP-B2 Additional 2-year warranty and 2-year service coverage, 24 hours/ day, 7 day/week (no holidays). PMP-C2 Additional 2-year warranty and 2-year service coverage, 24 hours/ day, 7 day/week (includes holidays).

PMP-A3 Additional 3-year warranty and 3-year service coverage, weekdays, M-F, 8AM to 5PM EST. PMP-B3 Additional 3-year warranty and 3-year service coverage, 24 hours/ day, 7 day/week (no holidays). PMP-C3 Additional 3-year warranty and 3-year service coverage, 24 hours/ day, 7 day/week (includes holidays).

Service Coverage Includes:


Inspect all battery connections for the presence of corrosion. Clean and retighten all connections to factory specifications Check and recalibrate all input and output parameters and settings Check cooling fans Exercise all circuit breakers Verify the operation of all installed options and remote panels

Run and monitor a system performance check by simulating an input power outage and recording periodic battery readings Clean the inside and outside of all system cabinets Provide a list of any/all items that could possibly prevent the unit from performing its intended function during a power outage and recommend any preventive maintenance actions