Вы находитесь на странице: 1из 11

Technical Information Stacked Washer/Dryer

MLE19PNAY*, MLG19PNAW*
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual 16009423 for detailed installation, operating, testing, troubleshooting, and disassembly instructions.

! !

CAUTION

All safety information must be followed as provided in Service Manual 16009423.

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

Models WASHER: Power Source Voltage AC Fuse Requirement Spin Speed Capacity DRYER: Power Source Voltage AC Fuse Requirement Motor Airflow Exhaust Gas Rating (MLG Model) Electrical Rating (MLE Rating) Capacity Cabinet Dimensions Height Overall Width Depth Weight Crated (lbs/kg) Uncrated (lbs/kg) Makeup Air Static Pressure

MLE19PNAY*, MLG19PNAW*

120 VAC 15 Amp 800 r.p.m. (200 gs) 2.9 cubic feet (0.08 cu.m).

Gas - 120 VAC, Electric - 220 VAC Gas - 15 Amp, Electric 30 Amp HP 120 Volt 220 cubic feet (60.2 cu.m.) per minute 4 (10.2 cm) diameter rigid aluminum duct 24,000 BTU/hr. for the drying chamber 5900 watts (6300 watts including washer) 6.0 Cubic Feet 71.5 (112.1 cm) 27-3/16 (69.1 cm) 27-1/2 (69.9 cm) 335-lbs (152-kg) 303-lbs (137-kg) Requires 36 sq.inch Should not exceed .92 or less than 0 water column inches

January 2004

16022935 Rev 0

Component Testing Procedures

!
Diagnostic Mode:

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

This mode is entered by depressing the WASHER KNITS & DELICATES for 1 second while in any of the set-up codes one through six, anytime a diagnostic code is present, or while dAS displays if operating with Maytag Data Acquisition setup. On entry to diagnostic mode the entire display will flash, a cycle in process is cancelled, money in escrow is cleared, and diagnostic codes are cleared. If a diagnostic code persists, it must be corrected before the following cycle options are permitted. Procedures to initiate cycle activity from diagnostic mode are as follows: 1. Washer Field Diagnostic Cycle - With the entire display flashing, the cycle is started by depressing the WOOLENS key pad. This cycle provides a quick verification that the cold and hot water valves, dispenser valves, pump, motor, and door lock are working. It is also a method to quickly get into a drain and spin to remove water from the machine if desired. Pressing the WASHER KNITS & DELICATES key pad will cancel this cycle and exit the diagnostic mode. 2. Washer Cycle Credit - With the entire display flashing, a cycle may be credited by pressing the WASHER PERMANENT PRESS keypad (CC will display). When the service mode is exited SELECT CYCLE will be displayed unless the end-of-cycle door opening is required. 3. Washer Operational Diagnostic Cycle - With the entire display flashing, this cycle is started by pressing the WASHER WHITES keypad. This cycle provides more typical full length fills, tumbles, and drains allowing for a more thorough analysis of machine operation including pressure switch behavior. 4. Dryer Field Diagnostic Cycle - With the entire display flashing, this cycle is started by pressing the DRYER PERMANENT PRESS keypad. The cycle consists of seven minutes of heat and one minute of cool down. The DRYER WHITES & COLORS keypad will increment the diagnostic cycle minutes up to 99, then roll over to 2 minutes. Pressing the WASHER KNITS & DELICATES keypad will cancel this cycle and exit the diagnostic mode.

Diagnostic Codes:
If the set-up mode is entered and one of the following has occurred, the appropriate diagnostic code will be display. d1 - Dryer door sense error on control board or due to power line interference. d2 - Washer door sense error on control board or due to power line interference. d4 - Dryer motor control circuit error. d5 - Blocked coin 1 or coin drop control circuit failure. d7 - Slow fill detected during previous cycle. d8 - Last drain was slow. d9 - Voltage detected below 90vac for 8 seconds. d10 - Washer door lock sense error or due to power line interference. d11 - Washer motor speed error detected. d12 - Dryer motor sense error on control board or due to power line interference. d13 - Blocked coin 2 or coin drop control circuit failure. d16 - Not receiving communications from installed debit card reader in Enhanced (Generation 2) Debit mode.

16022935 Rev 0

January 2004

Component Testing Procedures

!
Washer Motor Phases

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

With the introduction of the sensorless motor, the motor phase test is no longer required. If the motor Experiences a phase problem, the motor will not run.

Washer Motor & Washer Motor Control Test


1. Disconnect power to the washer. 2. Remove the front panel and pull the JP4 Connector from the motor control board. 3. Supply power to the motor controller with an external power cord. 4. The motor control will immediately execute a routine and the motor should run, rotating the spinner at 50 rpm. 5. If the motor runs and the spinner rotate at the proper RPM speed: the problem lies outside of the motor and motor control circuit. Disconnect power to the washer and reconnect the JP4 Interface connector to the motor control. If the motor runs and the spinner does not rotate: check for missing belt. 6. If the motor does not run: A. The terminals in the 6-position connector on the Motor should be the same height. Remove the connector and replace the motor if any of the connectors are pushed into the motor. B. If no damage is present, check motor windings for any open circuits. Replace motor if necessary. C. Check the 10-amp fuse located on the control board, either visually or with an ohmmeter. If bad, replace motor control/wire harness assembly completely. D. If the fuse is functioning, check the six semiconductors on the heat sink visually for any damage. If damaged, replace motor control/wire harness assembly completely. 7. Unplug the washer power cord and replace motor control board connector JP4 when finished.

MOTOR CONNECTOR
BROWN GREEN BLACK WHITE GRAY GRAY

-6-

-5-4-

-3-

-7-

-2-

155-195 OHMS

-16-7.5 OHMS

January 2004

16022935 Rev 0

Wiring Diagram

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

MLG19PNAW* SCHEMATIC (Lower Washer)


GN MOTOR CONTROL PWM GROUND MOTOR CONTROL TACH. PRESSURE SWITCH -20.7 VDC
1 2 3 4 5 6 7 8

-8.5 VDC

9 10 11 12 13

LOWER INTERCONNECT CAP (RH)

LOWER WASHER ELECTRICAL SCHEMATIC

-8.5 VDC

STRUT DISPL. SWITCH

14 15

GN

MOTOR CONTROL
GND

DOOR LOCK SWITCH FAB. SOFTENER HOT WATER VALVE BK PRESSURE SWITCH GROUND COLD WATER VALVE N BLEACH PUMP L1 DOOR LOCK WAX MOT DOOR SWITCH MOT CNTRL L1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

MN4

MOTOR
1 2

WH
BR WH BK GY GY GN

WH

LOWER INTERCONNECT CAP (LH)

T
GN

WH42

JP4

YL29 RD30 BU47

PRESSURE SWITCH
PU
WASH LEVEL 34-NO
31-COM

FULL BR FULL YL CAPACITOR

PK COM OR NC BU COM NC BU COM NC OR COM NC

PU

PU

32-NC RINSE LEVEL


14-NO 12-NC

UPPER TUB DISPLACEMENT SWITCH LOWER TUB DISPLACEMENT SWITCH INERTIAL UNBALANCE SWITCH STRUT DISPLACEMENT SWITCH

GY 11-COM

DOOR LOCK SWITCH


YL COM NO RD

GND

WATER VALVE
FAB. SOFTNER BLEACH BU COLD OR HOT WH PU PK

WH BK COM NO GY

WH WH

DOOR SWITCH
CAPACITOR

63719440
WH

DOOR LOCK WAX MOTOR


BR

DRAIN PUMP
BK

WH

16022935 Rev 0

January 2004

Wiring Diagram

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

MLG19PNAW* SCHEMATIC (Upper Dryer)


TRANSFORMER
BK 5.3 VAC YL BU WH RD BU 20.8 VAC 26 VAC BK WH RD
1 2 3 4 5 6 7 8

YL BU WH RD BU WH RD

GN

TRANSFORMER PLUG

1 2 3 4

RD YL BR BU

UPPER INTERCONNECT PLUG (RH)

5 6 7 8 9 10 11 12 13 14 15

PU PK PU YL OR BK OR BK

BU

YL WH

(+)

GN RD PU OR YL BU WH PK BK YL BR GY BK

CONN EE1
1 2 3 4

CONN AA8

CONN AA5 CONN AA12

1 2 3 4 5

BATTERY (OPTIONAL)

(-)

1 7

2 8

3 9

4 10

5 11

6 12

UPPER INTERCONNECT PLUG (LH)

6 7 8 9 10 11 12 13 14 15

10 5

9 4

8 3

7 2

6 1

CONN AA10

COIN 2 SENSOR

(OPTIONAL)
RD BR

TRANSFORMER PLUG

MACHINE CONTROL

8 4 7 3 6 2 5 1 1 3 2 4

GY

BB7

1 4

2 5

3 6

CONN AA7
YL

BU BK

PK

YL

BK

CONN BB6

BB1

CONN AA4

2 1

4 3

1 1

ENABLE 2 ENABLE 1

AVAIL 1

-20.7 VDC

5.7 VDC

AVAIL 2

GY

BK RD

YL

PK OR

PK

63719440
RD

140 CYCLING THST

BR

240 HI - LIMIT THST 155 CYCLING THST


BK

PU

DOOR SWITCH
RD OPEN WH BU CLOSED OPEN YL OR CLOSED

GY

GND

N
N

THERMAL FUSE
GY GY OVERLOAD PROTECTOR

BK RD

BU BU

RD

WH

BK

R U N

GAS VALVE

ACCESS SWITCH

S T A R T

DM RO I T VO ER

HOLDING COIL BOOSTER SECONDARY COIL COIL

IGNITER

2
BU

COIN 1 SENSOR
L1
L 1
YL

GY

EXTERNAL DEBIT CARD CONNS CONN AA2 CONN AA3 2

CENT SWITCH

BK

RD

BK

BK

UPPER DRYER - PN ELECTRICAL SCHEMATIC


January 2004 5 16022935 Rev 0

RADIANT SENSOR

AVAIL 4 AVAIL 3

Wiring Diagram

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

MLG19PNAW* WIRING DIAGRAM (Lower Washer)


GN RD 30 YL 29 BR 12 BU 47
1 2 3 4 5 6 7 8 NUMBERS INDICATE LO CATION OF WIRE IN HOU SING

LOWER INTERCONNECT CAP (RH)


RD 30 BR 12 1 GN 2 3 YL 29

PU 15 PK 1

9 10 11 12 13

BU 47

5 6

OR 40

14 15

7 PU 15

8 9 PK 1 11 12 OR 40 14 15

DISPENSER VALVE
CAP
PU 2 PK 5 BU 9 OR 52 WH 57

GN RD 17 PU 2 OR 52 YL 22 BU 9 WH 36 PK 5 BK 35 YL 33 BR 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

WIRE INSERTION SIDE

LOWER INTERCONNECT CAP (LH)


RD 17 YL 22 1 PU 2 2 3 OR 52 BU 9

N UMBER S INDIC ATE LOCATION OF WIR E IN HOUSING

GN 4 PK 5 5 6

BU
COM

BU
NC

GY 37 BK 7

WH 36 7 BK 35

8 9

INERTIAL UNBALANCE SWITCH


BU
CO M NC COM NC

OR 41

YL BR 33 14 11 12 BK GY 7 37 14 15

OR 40

BU

LOWER TUB DISPLACEMENT SWITCH


CO M NC

STRUT DISPLACEMENT SWITCH


YL 22

WIRE INSERTION SIDE

PU 15 PU 11
12 31 34 32

UPPER TUB DISPLACEMENT SWITCH


BU BU OR 41 PK 1 PU 11

DOOR SWITCH
BK 44 GY 37 BR 14

DOOR LOCK WAX MOTOR


WH 13 WH 57

14

11

BR 12

GND
GY 21

PRESSURE SWITCH

GY 21

LINE CONNECTOR

BK 44
COM

YL 33 RD 17

NO

GN MN4 BK7 WH36 WH39 BR WH BK GY GY GN

GN GY GY BK WH BR

WH 13 WH 39 BK 35

DOOR LOCK SWITCH

DRAIN PUMP

63719440

WH42 JP4 YL29 RD30 BU47

LOWER WASHER WIRING CONNECTION DIAGRAM

MOTOR CONTROL

16022935 Rev 0

January 2004

Wiring Diagram

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

MLG19PNAW* WIRING DIAGRAM (Upper Dryer)


UPPER INTERCONNECT PLUG (RH)
YL 29 3 2 GN 6 5 4 1 RD 30 BR 12
GN
1 2 3 4 5 6 7 8 9 10 11 12 13 14

RD 30 YL 29 BR 12 BU 47
YL BU
1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

BK PU 15 PK 1 BK

WH RD BU WH RD

YL 65 BU 56 WH 3 RD 4 BU 16 WH 49 RD 48

BU 47

9 8

15

OR 40

INLINE CONNECTOR
YL BU WH RD BU WH RD
8 1

PK 1

OR 40 15 14

GN
1 2 3 4

YL 33

RD 17 PU 2 OR 52 YL 22 BU 9 WH 36 PK 5 BK 35 YL 33 BR 14 GY 37 BK 7

WIRE INSERTION SIDE

5 6 7

PU 15

YL 18

12

11

UPPER INTERCONNECT PLUG (LH)


OR 52 BU 9 3 2 PU 2 1 RD 17 YL 22 WH 36 BK 35

8 9 10 11 12 13 14 15

BATTERY (OPTIONAL)
WH 54

COIN 2 SENSOR
(OPTIONAL)

MACHINE CONTROL

RD 4 WH 3 BU 56 YL 65

RD 48 WH 49 BU 16

4 3

6 5 GN 9 8

CONN AA5 CONN AA12


YL 29 YL 43 7 PU 15 BU 47 8 BR 12 PK 60 OR 40 BK 55 11 RD 30 12 6 5 4 3 2 1

1 2 3 4

2 1

1234

PK 5 YL 33

10 BU 9 PK 5 5

9 YL 22

OR 52 BR 14

7 PU 2

6 RD 17 WH 54

CONN AA8 CONN AA10 BB7


GY 37
1 YL 34 4

12

RD 32 BR 51

GY 6

YL 64 BK 35

CONN BB6

BB1
BK 7

YL 34

WIRE INSERTION SIDE


BU 46

PK 60 GY 50

BR 51

140 CYCLING TH'ST

THERMAL FUSE
GY 6 PU 20

WH 36

PK 1

GY 31

RD 32 RD 61

DOOR SWITCH
BU 62

OR 52 BU 46 BU 38 GN BK 19 WH 24 BK 53

YL YL 64 34

N LI G

INLINE CONNECTOR

POWER CORD

63719440
7

UPPER DRYER PN WIRING CONNECTION DIAGRAM

RADIANT SENSOR

BK 25 WH 26 WH 28

BK 27

January 2004

GY BK 37 7 15 14

YL 18

BR 14

11

CONN EE1 CONN AA7


GY 6

CONN AA3 654321

CONN AA2 21

CONN 2 4 AA4 1 3

EXTERNAL DEBIT CARD CONNS

COIN 1 SENSOR

240 HI-LIMIT TH'ST

YL 43

BK 55

OR 52

155 CYCLING TH'ST

ACCESS SWITCH

IGNITER

RD 23

GAS VALVE

16022935 Rev 0

Wiring Diagram

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

MLE19PNAY* SCHEMATIC (Lower Washer)


GN MOTOR CONTROL PWM GROUND MOTOR CONTROL TACH. PRESSURE SWITCH -20.7 VDC
1 2 3 4 5 6 7 8

-8.5 VDC

9 10 11 12 13

LOWER WASHER ELECTRICAL SCHEMATIC


BU RD YL

-8.5 VDC

STRUT DISPL. SWITCH

14 15

GN

LOWER INTERCONNECT CAP (RH)


DOOR LOCK SWITCH FAB. SOFTENER HOT WATER VALVE PRESSURE SWITCH GROUND COLD WATER VALVE N BLEACH PUMP L1 DOOR LOCK WAX MOT
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15

JP4

WH

GN
GY GY BK WH BR

WH

MN4

WH BK

DOOR SWITCH MOT CNTRL L1

GN

MOTOR CONTROL
PU PK COM NC BU COM OR NC BU COM NC OR COM NC PU PU

PRESSURE SWITCH
WASH LEVEL 31-COM 32-NC RINSE LEVEL 14-NO GY 11-COM 12-NC 34-NO

LOWER INTERCONNECT CAP (LH)

FULL BR FULL

UPPER TUB DISPLACEMENT SWITCH LOWER TUB DISPLACEMENT SWITCH INERTIAL UNBALANCE SWITCH STRUT DISPLACEMENT SWITCH

CAPACITOR

YL

DOOR LOCK SWITCH


YL COM NO RD

GND

WATER VALVE
WH FAB. SOFTNER PU PK

BK COM NO GY

WH WH

BLEACH BU COLD OR HOT

DOOR SWITCH

CAPACITOR

WH

DOOR LOCK WAX MOTOR


BR

WH

63720100

DRAIN PUMP
BK

WH

16022935 Rev 0

January 2004

Wiring Diagram

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

MLE19PNAY* SCHEMATIC (Upper Dryer)


TRANSFORMER
UPPER INTERCONNECT PLUG (RH)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

BK

5.3 VAC

YL BU WH RD BU

1 2 3 4 5 6 7 8

YL BU WH RD BU WH RD

GN

TRANSFORMER PLUG

RD YL BR BU

20.8 VAC 26 VAC BK

WH RD

PU PK YL

PU OR BK

(+)

GN RD PU OR YL BU WH PK BK YL BR

CONN EE1
1 2 3 4

WH
1 2 3 4 5 6 7 8 9 10 11 12 13

CONN AA8

CONN AA5

COIN 2 SENSOR

(OPTIONAL)

OR

BK

TRANSFORMER PLUG

MACHINE CONTROL

(-)

8 4 7 3 6 2 5 1

BATTERY (OPTIONAL)

1 7

2 8

3 9

10 11 12

CONN AA12
RD BR BU BK PK YL

1 3

GY RD

10 5

9 4

8 3

7 2

6 1

CONN AA10

RD

GY
1 4 2 5 3 6

BB7

CONN AA7

YL BK

2 3

CONN BB6

BB1

CONN AA4

14 15

GY BK
GY BK

1 1

ENABLE 2

ENABLE 1

AVAIL 1

-20.7 VDC

5.7 VDC

AVAIL 2

YL

UPPER INTERCONNECT PLUG (LH)

YL PK WH WH RD OR PK

140 CYCLING THST

DOOR SWITCH
OPEN RD WH CLOSED OPEN YL OR CLOSED

THERMAL FUSE HEATER THERMAL FUSE

GY RD YL

GY

HEATER RELAY
GY PU GY GY OVERLOAD PROTECTOR W-BR

ACCESS SWITCH
S T A R T

200 HI - LIMIT THST HEATING ELEMENT


YL
1

BK

DM RO I T VO ER

R U N
RD PU

YL
YL BU

CENT SWITCH

BK

155 CYCLING THST


BK BU

RD

63720100

L2

WH BK

January 2004

16022935 Rev 0

UPPER DRYER - PN ELECTRICAL SCHEMATIC

L1 N

COIN 1 SENSOR
WH WH
2

GY

EXTERNAL DEBIT CARD CONNS CONN AA2 CONN AA3

RD

AVAIL 3

AVAIL 4

Wiring Diagram

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

MLLE19PNAY* WIRING DIAGRAM (Lower Washer)


GN RD 30 YL 29 BR 12 BU 47
1 2 3 4 5 6 7 8

LOWER INTERCONNECT CAP (RH)


RD 30 BR 12 1 GN 2 3 YL 29

NUMBERS INDICATE LOCATION OF W IRE IN HOUSING

PU 15 PK 1

9 10 11 12 13

BU 47

5 6

OR 40

14 15

8 9 PK 1 11 12 OR 40

DISPENSER VALVE
PU 2 PK 5 BU 9 OR 52

PU 15

CAP

GN RD 17 PU 2 OR 52 YL 22 BU 9 WH 36 PK 5 WH 57 BK 35 YL 33 BR 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

14 15

NUMBERS INDICATE LOCATION OF WIRE IN HOUSING

WIRE INSERTION SIDE

LOWER INTERCONNECT CAP (LH)


RD 17 YL 22 1 PU 2 2 3 OR 52 BU 9

BU
COM

BU
NC

GY 37 BK 7

INERTIAL UNBALANCE SWITCH


BU
COM NC COM NC

GN 4 PK 5 5 6

OR 41

OR 40

BU

LOWER TUB DISPLACEMENT SWITCH


CO M NC

STRUT DISPLACEMENT SWITCH


YL 22

WH 36 7 BK 35
PU 15 PU 11
12 31 34 32

8 9

YL BR 33 14 11 12 GY BK 7 37 14 15

UPPER TUB DISPLACEMENT SWITCH


BU BU OR 41 PK 1 PU 11

DOOR SWITCH
BK 44 GY 37 BR 14

DOOR LOCK WAX MOTOR


WH 13 WH 57

14

11

BR 12

GND

GY 21

PRESSURE SWITCH

WIRE INSERTION SIDE

GY 21

LINE CONNECTOR

BK 44
COM

YL 33 RD 17

NO

GN MN4 BK 7 WH 36 WH 39 BR WH BK GY GY GN

GN GY GY BK WH BR

WH 13 WH 39 BK 35

DOOR LOCK SWITCH

DRAIN PUMP

MOTOR CONTROL
JP4

WH42 YL29 RD30 BU 47

63720100

LOWER WASHER WIRING CONNECTION DIAGRAM

16022935 Rev 0

10

January 2004

Wiring Diagram

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer/dryer before servicing, unless testing requires power.

MLE19PNAY* WIRING DIAGRAM (Upper Dryer)


GN

UPPER INTERCONNECT PLUG (RH)


YL 29 3 2 GN 6 5 4 1 RD 30 BR 12

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

RD 30 YL 29 BR 12 BU 47
YL BU WH RD BU WH RD
1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

BK PU 15 PK 1 BK

YL 65 BU 56 WH 3 RD 4 BU 16 WH 49 RD 48

BU 47

OR 40

9 8

INLINE CONNECTOR
YL BU WH RD BU WH RD
8 1

12

11

YL 18

PK 1

PU 15
GN

YL 33

OR 40 15 14

1 2 3 4 5

RD 17 PU 2 OR 52 YL 22 BU 9 WH 36 PK 5 BK 35 YL 33 BR 14 GY 37 BK 7

WIRE INSERTION SIDE

6 7 8 9 10 11

BATTERY (OPTIONAL)
WH 54

MACHINE CONTROL

UPPER INTERCONNECT PLUG (LH)


OR 52 BU 9 3 2 PU 2 1 RD 17 YL 22

12 13 14 15

COIN 2 SENSOR
(OPTIONAL)
RD 4 WH 3 BU 56 YL 65 RD 48 WH 49 BU 16 5

4 3 2 1

CONN AA5 CONN AA12


YL 29 YL 43 7 PU 15 BU 47 8 RD 24 BR 12 PK 60 OR 40 BK 55 11 GY 28 RD 30 12 6 5 4 3 2 1

1 2 3 4

1234

6 5 GN 9 8

10 BU 9 PK 5 5

9 YL 22

OR 52 BR 14

7 PU 2

6 RD 17 WH 54

CONN AA8 CONN AA10 BB7


GY 37
1 YL 34

RD 32

GY 6

12

CONN AA4
BK 55 YL 43

YL 34
1

GY BK 37 7 15 14

BK 35

YL 64

CONN BB6

BB1

YL 34

WIRE INSERTION SIDE


WH 46 PK 60

BK 7

GY 6

YL 18 WH 36

THERMAL FUSE (HEATER)


GY 19

DOOR SWITCH

PK 1 WH 20

140 CYCLING TH'ST


OR 52

THERMAL FUSE
RD 32 RD 61

GY 31

YL 53

WH 20 YL 64 WH 46

GN YL 53 BU 27 BK 25

155 CYCLING TH'ST

L
BK 101

N
WH 100 PU 26

L2

L1
GROUND STRAP

TERMINAL BLOCK

63720100

UPPER DRYER -PN WIRING CONNECTION DIAGRAM

January 2004

11

BR 14

11

YL 33

BK 35

GY 20

PK 5

WH 36

CONN EE1 CONN AA7

CONN AA3 654321

CONN AA2 21

2 4 1 3

EXTERNAL DEBIT CARD CONNS

COIN 1 SENSOR

GY 28

RD 24

HEATER RELAY
PU 23

OR 52

ACCESS SWITCH 200 HI-LIMIT TH'ST

PU 23

W-BU 55

HEATER

16022935 Rev 0

Вам также может понравиться