Вы находитесь на странице: 1из 8

Straight Single Clapper Two-Way Inlets

A95
a

Exposed auxiliary inlet connection with 500 G.P.M. inlet capacity to supplement fire protection water supply. Exposed design provides an economical method of satisfying Fire Dept. inlet requirements. b Standard equipment: Cast brass two-way inlet body with single swing clapper and pin or rocker lug hose thread swivel; straight NPT outlet connection. Branding: AUTO SPKR

CERTIFICATIONS

CE x 1191 LISTED 166Y

2-1/2

4 x 2-1/2
a

A B
b

5-33/64 8-5/64

SPECIFY THREAD

90 Single Clapper Two-Way Inlets


A96
a

Exposed auxiliary inlet connection with 500 G.P.M. inlet capacity to supplement fire protection water supply. Exposed design provides an economical method of satisfying Fire Dept. inlet requirements. b Standard equipment: Cast brass two-way inlet body with single swing clapper and pin or rocker lug hose thread swivel; angle NPT outlet connection. Branding: AUTO SPKR

CERTIFICATIONS

CE x 1191 LISTED 166Y

2-1/2

4 x 2-1/2 A B C 8-5/64 6-11/16 4-29/32

SPECIFY THREAD

12

(Technical communication n A-007)

A95 Straight single clapper two-way inlets

Standard equipment Cast brass two-way inlet body with single swing clapper and pin or rocher lug hose thread swivel; straight NPT outlet connection.

Standard equipment Product Thread Construction Dimensions Function

Product An exposed auxiliary inlet connection with 500 gpm inlet capacity to supplement fire protection water supply. Exposed design provides an economical method of satisfying Fire Dept. inlet requirements. a 4" b 2 1/2" Branding AUTO SPKR Optional finishes: RP - Red painted

Standard equipment Product Thread Construction Dimensions Function

Thread
---- Abbreviation List ----

A95Y000 A95Y001 A95Y003 A95Y004 A95Y005 A95Y006 A95Y007

4" X 2 1/2" without swivel 4" X 2 1/2" NST PL 4" X 2 1/2" CSA RL 4" X 2 1/2" BCT RL 4" X 2 1/2" QST RL 4" X 2 1/2" WCT RL 4" X 2 1/2" NSST RL

Standard equipment Product Thread Construction Dimensions Function

file://E:\Notetecniche\NoteTecnicheENG\A95.htm

24/08/2006

A95Y008 A95Y009

4" X 2 1/2" NWFLD RL 4" X 2 1/2" NPSH RL Available also with red painted body

A95Y053 A95Y054 A95Y055 A95Y056 A95Y057 A95Y058

4" X 2 1/2" CSA RL Red 4" X 2 1/2" BCT RL Red 4" X 2 1/2" QST RL Red 4" X 2 1/2" WCT RL Red 4" X 2 1/2" NSST RL Red 4" X 2 1/2" NWFLD RL Red

Construction Cast brass two-way inlet body with single clapper and pin or rocker lug hose thread swivel.

Standard equipment Product Thread Construction Dimensions Function

Dimensions

A B

4" x 2 1/2" 5 33/64" 8 5/64"

Standard equipment Product Thread Construction Dimensions Function

Function Used as an auxiliary inlet connection providing 500 gpm minimum to supplement the fire protection water supply (NFPA 14 Section 5.9 and NFPA 13 Section 2.7). Swing clapper provides unobstructed waterway. Exposed design is an economical method of satisfying Fire Dept. inlet requirements.

Standard equipment Product Thread Construction Dimensions Function

file://E:\Notetecniche\NoteTecnicheENG\A95.htm

24/08/2006

(Technical communication n A-008)

A96 90 single clapper two way inlets


Standard equipment Cast brass two-way inlet body with single swing clapper and pin or rocher lug hose thread swivel; angle NPT outlet connection.
Standard equipment Product Thread Construction Dimensions Function

Product Branding An exposed auxiliary inlet connection with 500 AUTO SPKR G.P.M. inlet capacity to supplement fire protection water supply. Exposed design provides Optional finishes: an economical method of satisfying Fire Dept. RP - Red painted inlet requirement a 4" b 2 1/2"

Product Thread Construction Dimensions Function

Thread
---- Abbreviation List ----

A96Y000 A96Y001 A96Y003 A96Y004 A96Y005 A96Y006 A96Y007 A96Y008

SIAM 4" X 2 1/2" without swivel SIAM .4" X 2 1/2" NST PL SIAM. 4" X 2 1/2" CSA RL SIAM 4" X 2 1/2" BCT RL SIAM. 4" X 2 1/2" QST RL SIAM. 4" X 2 1/2" WCT RL SIAM. 4" X 2 1/2" NSST RL SIAM .4" X 2 1/2" NWFLD RL

Product Thread Construction Dimensions Function

Available also with red painted body A96Y053 SIAM. 4" X 2 1/2" CSA RL Red

file://E:\Notetecniche\NoteTecnicheENG\A96.htm

24/08/2006

A96Y054 A96Y055 A96Y056 A96Y057 A96Y058

SIAM. 4" X 2 1/2" BCT RL Red SIAM. 4" X 2 1/2" QST RL Red SIAM. 4" X 2 1/2" WCT RL Red SIAM 4" X 2 1/2" NSST RL Red SIAM. 4" X 2 1/2" NWFD RL Red

Construction Cast brass two-way inlet body with single clapper and pin or rocker lug hose thread swivel.

Product Thread Construction Dimensions Function

Dimensions

A B C

4" x 2 1/2" 8 5/64" 6 11/16" 4 29/32"

Product Thread Construction Dimensions Function

Function Used as an auxiliary inlet connection providing 500 gpm minimum to supplement the fire protection water supply (NFPA 14 Section 5.9 and NFPA 13 Section 2.7). Swing clapper provides unobstructed waterway. Exposed design is an economical method of satisfying Fire Dept. inlet requirements.

Product Thread Construction Dimensions Function

file://E:\Notetecniche\NoteTecnicheENG\A96.htm

24/08/2006

VSQV.EX3314 - Fire Department Connections

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...

VSQV.EX3314 Fire Department Connections


Page Bottom

Fire Department Connections


See General Information for Fire Department Connections GIACOMINI SPA VIA PER ALZO 39 28017 S MAURIZIO D'OPAGLIO, NOVARA ITALY Exposed type. Model A95 A96 A105 A106 A105 A106 A90C A91C Flush type. Model A101 A102 A190T Pattern Straightway 90 Degree Single inlet Size (in.) 4 by 2-1/2 by 2-1/2, 4 by 3 by 3, 6 by 2-1/2 by 2-1/2 4 by 2-1/2 by 2-1/2, 4 by 3 by 3 1-1/2 Rated Pressure (psig) 175 175 175 Pattern Straightway 90 Degree Straightway 90 Degree Straightway 90 Degree Straightway Straightway 4 by 2-1/2 by 2-1/2 4 by 2-1/2 by 2-1/2 4 by 2-1/2 by 2-1/2 4 by 2-1/2 by 2-1/2 4 by 3 by 3, 6 by 3 by 3 4 by 3 by 3, 6 by 3 by 3 3 by 2-1/2 3 by 2-1/2 Size (in.) 300 300 175 175 300 300 300 300 Rated Pressure (psig) EX3314

Trademark and/or Tradename: Last Updated on 2010-05-28 Questions? Print this page Notice of Disclaimer Page Top Copyright 2010 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2010 Underwriters Laboratories Inc."

1 de 2

19/07/2010 02:28 p.m.

VSQV.EX3314 - Fire Department Connections

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...

2 de 2

19/07/2010 02:28 p.m.

Fire Service Connections


A fire service pumper connection, located outside buildings, permits the fire service to pump water into a sprinkler system from a nearby public hydrant or reservoir. Water supplied at high pressure will aid automatic sprinklers to control a fire. The connection may also be used to supply building standpipes. FM Approved connections are made of bronze and consist of two inlet couplings threaded for standard fire hose and siamesed into an outlet pipe connection. A check valve is provided in each inlet so that either connection may be used separately. The connections are available in straight, 45 or 90 patterns. Unless otherwise noted in the listing, these connections have 175 psi (1205 kPa) rated working pressure.

Fig. Nos. A95, A96, A105, A106


Nominal Size, Inlets x Outlet, in. 2 12 x 2 12 x 4 2 12 x 2 12 x 4 2 12 x 2 12 x 4 2 12 x 2 12 x 4

Fig. No. A95 A96 A105 A106

Component Description Straightway Siamese 90 Siamese Straightway Siamese 90 Siamese

Company Name: Giacomini SpA Company Address: Strada Per Alzo 39, 28017 S Maurizio d'Opaglio, Italy Company Website: http://www.giacomini.com Listing Country: Italy Certification Type: FM Approved

2007-2010 FM Approvals. All rights reserved.

1 of 1