LS-VINA Cable is the top leading cable company in the

ASEAN as a biggest subsidiary of LS Cable Korea who is No. 3


biggest and advanced cable maker in the world. We are
specialized in manufacturing of various power cables, low
voltage cables up to 1kV, Medium voltage cables up to 40.5kV,
High voltage underground cables up to 230kV, electric wires,
Copper/ Aluminum bare conductors, High current capacity
conductor, OPGW, watertight cable, fire retardant, non toxic, antitermite and oil resistant cable..., to meet domestic and overseas
demand. Many products were tested by the local and
international laboratories as KEMA/Holland,
KINECTRICS/Canada, INTERTEK/America, ERDA/India, TUV
Rheinland/German ,Quatest 1, Quatest 3...
In this catalogue, we offer several fire resistant cables to IEC
60331(or BS 6387) and flame retardant cables to IEC 60332(or
BS 4066).
LS-VINA Cable l cng ty sn xut cp in ng u ng
Nam . i tc gp vn nc ngoi l LS Cable Hn quc m
hin l mt trong 3 nh sn xut cp ln nht th gii. Chng ti c
nhiu nm kinh nghim sn xut cp in vi a dng sn phm
nh cp h th in p n 1kV, cp trung th in p n 40.5
kV, cp ngm cao th in p n 230kV, dy in dn dng cc
loi, dy nhm trn, ng trn, c bit l cp chu dng ti cao,
dy chng st c si quang (OPGW), cp chng thm, chng
chy, khng c, chng mi mt v chu du... p ng tt nhu
cu th trng trong v ngoi nc. Nhiu sn phm c
chng nhn bi cc phng th nghim c lp trong nc v Quc
t nh KEMA/H Lan, KINECTRICS/Canada, INTERTEK/M,
ERDA/n , TUV Rheinland/c, Quatest1, Quatest 3, v.v...
Trong catalogue ny chng ti s gii thiu mt s loi cp
chng chy theo IEC 60331(or BS 6387) v chng bn chy theo
IEC 60332(or BS 4066).

Contents/Ni dung
Introduction

Gii thiu

Fire resistant & LSHF fire resistant cables

Cp chng chy & chng chy t khi khng Halogen

- 0.6/1kV Unarmoured XLPE cables

Cp XLPE khng c gip bo v 0.6/1kV

- 0.6/1kV Single core armoured XLPE cables

Cp XLPE n pha c gip bo v 0.6/1kV

- 0.6/1kV Multi-core armoured XLPE cables

Cp XLPE nhiu li c gip bo v 0.6/1kV

- 600V Insulated wires

Dy bc n 600V

Flame retardant & LSHF Flame retardant cables

Cp chng bn chy & chng bn chy t khi khng Halogen

- 0.6/1kV Unarmoured XLPE cables

10

Cp XLPE khng c gip bo v 0.6/1kV

- 0.6/1kV Single core armoured XLPE cables

11

Cp XLPE n pha c gip bo v 0.6/1kV

- 0.6/1kV Multi-core armoured XLPE cables

12

Cp XLPE nhiu li c gip bo v 0.6/1kV

- 600V Insulated wires

13

Dy bc n 600V

- 0.6/1kV Control Cables

14

Cp iu khin 0.6/1kV

Certificate test
Giy chng nhn kim tra

17

Specifications

Introduction

Tiu chun qui nh

Fire Resistant Tests

IEC 60331
/BS 6387

Residents, owners and regulatory authorities of buildings are now, more than
ever, protected by stringent safety requirements. Electrical installations particularly fire alarm systems, sprinklers, smoke detection and extraction
equipment, emergency lighting and evacuation systems, elevator - all merge
to prevent harm to people and damage to buildings and equipment.
The wiring behind the systems prove to be an important factor in preventing
fires from spreading, and stopping smoke from choking off exit points and
allowing a safe rescue. If the wiring is adversely affected, the systems
themselves will have no power to provide their own critical functions.

Specification performance requirements


for cables required to maintain circuit integrity
under fire conditions.
Quy nh yu cu thc hin cho cp
l duy tr mch in trong iu kin chy.

Stringent tests - including IEC 60331, BS 6387 - are performed to ensure that
such cables are fire-resistant.

In accordance to IEC 60331:


o

Cable are subjected to fire at 750 C for 3 hours. In not less than twelve hours after the test, the cable shall
again be energized, and there shall not be any breakdown.

In accordance to BS 6387:
Category A - Cable are subjected to fire at 650o C for 3 hours.
Category B - Cable are subjected to fire at 750o C for 3 hours.
Category C - Cable are subjected to fire at 950o C for 3 hours.
Category Z - Cable are subjected to fire at 950o C with mechanical shock for 15 minutes.
Category W - Cable are subjected to fire at 650o C for 15 minutes, then at 650o C with water spray for a further 15 minutes.

Hin nay, cc ta nh, chung c hay cng trnh (Trm in, nh my...)
xy mi u c quy nh nghim ngt v an ton chy n, nn vic lp t
cc h thng bo chy, thit b pht hin khi, h thng n cp cu, n
chp, tn hiu, thang my... Tt c l bo v an ton tnh mng con ngi
v ti sn.
Cp chng chy s dng trong h thng in ng vai tr l nhn t quan
trng trong vic gim s ly lan ca la, khng sinh ra khi, cc thit b nh
n tn hiu, thang my v h thng bo chy vn lm vic khi c chy, m
bo cu h an ton v thot him. Nu cp in l loi thng s khng p
ng c yu cu ny.
Cp in dng trong mch in chng chy s phi tha mn th nghim
theo tiu chun IEC 60331, BS 6387 qui nh.

Th chng chy theo IEC 60331:


o

Cp c th 750 C cho 3 gi. Sau c th li t nht 12 gi, cp c hot ng bnh thng, v


khng b gin on

Th chng chy theo BS 6387:


o

Category A - Cp c th 650 C cho 3 gi.


o

Category B - Cp c th 750 C cho 3 gi.


Category C - Cp c th 950o C cho 3 gi.
Category Z - Cp c th 950o C trong s va p c hc cho 15 pht.
Category W - Cp c th 650o C cho 15 pht, sau phun nc v 650o C cho thm 15 pht.

Specifications

Introduction

Tiu chun qui nh

Flame Propagation Tests

IEC 60332
/BS 4066

Tests on electric cables under fire conditions.


Part 1 : Tests on a single vertical insulated wire or cable
Part 3 : Tests on bunched wires and cables under fire condition.
When Projects are constructed (as building, substation, plant...), Cables traverse walls and
ceilings to create a web of electrical power. Unfortunately, these cables also act as conduits
for fire and heat, so cables must be fashioned of inflammable and self-extinguishing
components. This can be achieved by utilising a protective material containing aluminium
hydroxide. In the event of fire, the material releases water crystals, and at the same time
produces water vapour, which stops the entrance of oxygen and snuffs out the flame.
The IEC 60332-3 specification creates a realistic fire situation, and specifies methods for
assessing the flame retardance of bunched cables with varying densities of combustible
material.

Bunched cables under fire conditions.


B cp trong iu kin chy.

This technical report gives details of a test where a number of cables are bunched together to
form various test sample installations.

3 tests categories to test different amount of combustible material contained in a bundle of cable.
IEC 60332-3-22
(Former IEC 332-3A)
IEC 60332-3-23
(Former IEC 332-3B)
IEC 60332-3-24
(Former IEC 332-3C)

- The number of test pieces required to provide a total volume of 7 litres of non-metallic
material shall be bunched on a ladder exposed to flame for 40 minutes.
- The number of test pieces required to provide a total volume of 3.5 litres of non-metallic
material shall be bunched on a ladder and exposed to flame for 40 minutes.
- The number of test pieces required to provide a total volume of 1.5 litres of non-metallic
material shall be bunched on a ladder and exposed to flame for 20 minutes.

The cable specimens are placed vertically next to each other and then exposed to the flame for a specified duration. After the
burning has ceased, the charred or affected portion should not exceed a height of 2.5 meters.

Kim tra cp trong iu kin chy.


Phn 1: Th nghim dy n v cp n cch in trng thi thng ng
Phn 2 : Th nghim trn b dy v cp trong iu kin chy.
Khi xy dng cc cng trnh, d n (Ta nh, trm in, nh my...), nhiu cp c lp t i
ngang qua tng v trn to thnh mng li cung cp in cho cc cng trnh . Khi gp
chy nhng cp lun c vai tr nh ng dn la v nhit. V vy cp s c ch to t
nhng vt liu kh chy v t tt m c hm lng hydroxyt nhm, vt liu ny s sinh ra nhiu
tinh th nc, ngn nga s tip xc vi oxy v lm tt ngn la.
IEC 332-3 a ra mt trng thi chy thc ti, v ch r phng php cho vic nh gi b cp
chng bn la vi loi vt t c nhiu mc bt la.
Cc ti liu k thut a ra c th php kim tra m mt s cp c b vi nhau to thnh
nhiu cch t mu kim tra.

C 3 mc kim tra tu theo lng cht t khc nhau thu c trong mt b cp.
IEC 60332-3-22 - S mu yu cu cung cp mt lng 7 lt vt liu phi kim loi s c b trn thang v t trong

40 pht.

IEC 60332-3-23 - S mu yu cu cung cp mt lng 3,5 lt vt liu phi kim loi s c b trn thang v t trong

40 pht.

IEC 60332-3-24 - S mu yu cu cung cp mt lng 1,5 lt vt liu phi kim loi s c b trn thang v t trong

20 pht.

Cc mu cp c t thng ng cnh nhau v t trong thi gian quy nh. Sau khi tt ngun t, phn thnh than s khng vt
qu 2,5 mt.

Introduction

Specifications
Tiu chun qui nh

Acid Gas Emission Tests

IEC 60754
/BS 6425

Test on gases evolved during combustion of electric cables.


A fire can produce corrosive halogen gases, generated by burning PVC or chlorine containing material. HCI gas combines with the water
in the eyes, mouth, throat, nose and lungs to form hydrochloric acid, which contributes to loss of co-ordination and orientation. This in
turn can lead to a feeling of panic and inability to exit the building, thus increasing potential fatalities by inhalation of carbon monoxide
and oxygen depletion.
Additional dangers exist in a fire situation. Chlorine, bromine or fluorine, found in building materials, can combine with the condensation
on all metallic materials in the proximity of a fire thus resulting in high levels of corrosion which will damage computers and office
machines. Structural ferrous metals can be so corroded that the building has to be demolished.
IEC 60754-2 or BS 6425 specifies a method in determining the degree of acidity of gases evolved during the combustion of materials
taken from electric cables by measuring pH and conductivity. This standard requires the weighted pH value of not less than 4.3 when
related to 1 litre of water, and the weighted value of conductivity should not exceed 10 mS/mm.

Kim tra s sinh kh trong khi cp chy


La chy c th sinh ra Halogen do vic t chy PVC hay cc nguyn liu khc. Kh HCL kt hp vi nc trong mt mi ming, hi th
v phi s to thnh axit hidrochloric gy mt phng hng con ngi. iu ny s gy ra s hong lon do vy khng th t thot ra
khi m chy v lm tng nguy c t vong v suy h hp do ht phi kh carbon monoxit.
Hn na, trong khi chy cc cht chlorine, bromine hay fluorine c trong cc vt liu ca to nh kt hp vi cc vt liu kim loi xung
quanh lm hng h thng my tnh, thit b vn phng v lm ph hy ton b to nh.
IEC 60754-2 qui nh phng php tnh acid ca kh trong qu trnh t chy vt liu trn cp bng cch o pH v dn in.
m S/mm.
Phng php ny qui nh t trng ca pH khng nh hn 4,3 trong 1lt nc, v dn in khng vt qu 10m

Smoke Emission Tests

IEC 61034
/BS 7622

Measurement of smoke density of electric cables burning


under defined conditions.
Smoke hinders fire-fighting efforts and prevents safe evacuation from the building. Smoke extraction equipment helps, but low
smoke products can stop the problem before it starts. Conventional insulation and sheathing materials such as polyvinyl chloride
(PVC) can produce large volumes of smoke when burned, thus contributing to disorientation and smoke inhalation damage.
Measuring the density of smoke produced by burning cables is important as it is related to the evacuation of people and accessibility for
fire fighting.
The 3 meter cube test (also known as IEC 61034 or BS 7622) measures the amount of smoke created by cables in the event of a fire. A
one-meter length of cable is placed in a 3m2 enclosure, and exposed to a beam of light through a clear window. This light travels across
the enclosure to a photocell connected to recording equipment in the window on the other end. A fire is then generated within the
container and the minimum light transmission recorded. A minimum light transmission value greater than 60% is acceptable.

o mt khi khi cp chy sinh ra


Khi gy cn tr cho vic cha chy v di chuyn dn c khi v tr m chy. Thit b ht khi c th hn ch c khi, nhng vic s
dng cc loi sn phm c hm lng khi t c th ngn chn nguy c ny ngay t u. Vt liu cch in v v bc thng thng nh
PVC c th sn sinh ra lng khi ln khi chy, nh vy s gy ra s mt phng hng v tn hi do ht khi.
Vic o mt khi sinh ra khi t l rt quan trng bi n lin quan ti vic di tn ca con ngi v kh nng tip cn cha chy.
o lng khi sinh ra trong bung kn (3 m3) khi cp c t (theo IEC 61034 or BS 7622). Mt mt chiu di cp c t trong bung
rng 3m2 v d quan st bung sng thng qua ng knh r nt. Ngun sng ny s xuyn qua bung ti mt t bo quang c ni vi
thit b ghi trong ng knh pha u kia. Mt ngn la c pht ra sau v ghi li mc nh sng truyn i. nh sng truyn i nh nht
phi ln hn 60%.

fire resistant & lshf fire resistant cables

Cp chng chy v chng chy t khi khng Halogen

Feature :
Safety is main features of electric cable in installation especially in the performance of cable under fire condition.
Althrough cables seldom cause fire, can be a carrier of fire and spread the fire throughout the installation or
equipment.
Fire resistant cables of LS-VINA Cable can maintain essential circuits as light, fire alarm equipment when fire occur
and critical areas of an installation, tunnels, mass rapid transit system, oil-rigs, oil refineries...
Low Smoke Halogen Free Fire resistant cable:
It does not liberate large volume of dense black smoke in fire condition, improve safety in area where there are
limited means of escape in the event of an emergency.
It does not emit any halogen gases when the cables is on fire. There are acidic and will attack equipment and
human being.

Applied standards
IEC 60502:
IEC 60331 (or BS 6387):
IEC 60332-1:
IEC 754-1 & 2 (or BS 6425):
IEC 61034-2 (or BS 7622):

Structure and dimension


Fire resistance
Flame retardant (Single vertical)
Halogen Free Properties
Low Smoke Properties

c im:
An ton s dng l c im cn bn ca dy v cp in, c bit khi c ho hon, mc d cp t khi l tc nhn gy
chy nhng cp in s l vt dn in n nh ca v thit b.
Cp chng chy ca LS-VINA Cable s khc phc iu ny, c th duy tr cc mch in thit yu nh chiu sng,
thit b bo chy khi xy ra chy v cc khu vc nhy cm ca cc cng trnh, ng hm, h thng trung chuyn
hnh khch, dn khoan, nh my lc du...
Cp chng chy t khi v khng c Halogen:
Cp t khi (LS) khi gp la khng sinh ra nhiu khi gi an ton cho nhng khu vc ng ngi d thot him.
Cp khng sinh khi Halogen (HF)Khi chy khng sinh kh Halogen nn khng to acid clohydric lm hi cho
ngi v thit b.

TIU CHUN P DNG


IEC 60502:
IEC 60331 (or BS 6387):
IEC 60332-1:
IEC 754-1 & 2 (or BS 6425):
IEC 61034-2 (or BS 7622):

Kt cu v kch thc
Chng chy
Chng bn la (n thng ng)
c tnh Halogen
c tnh t khi

0.6/1 kv fire resistant cable


Cp chng chy 0.6/1 kV
IEC 60331/BS 6387

Unarmoured XLPE cable - Cp XLPE khng c gip bo v


Cross- Diameter of Thickness
sectional conductor
of
area
insulation

Thickness of outer
sheath

Approx. overall diameter

Approx. weight of cable

ng knh tng

Khi lng cp gn ng

(mm)

(kg/km)

Chiu dy v bc

(mm)

Tit din
danh nh

ng knh
li

Chiu dy
cch in

(mm2)

(mm)

(mm)

1c

2c

3c

4c

1c

2c

3c

4c

1c

2c

3c

4c

1.5
2.5
4
6
10

1.56
2.01
2.55
3.12
4.05

0.7
0.7
"
0.7
"

1.4
1.4
"
1.4
"

1.5
1.5
"
1.8
"

1.5
1.5
"
1.8
"

1.5
1.5
"
1.8
"

7.0
7.5
8
9
10

11.0
13.5
14
15
18

11.5
14
15
16
19

12.5
15
17
18
20

60
80
99
125
170

125
195
235
290
410

150
230
295
370
520

170
285
360
455
660

16
25
35
50
70

5.1
6.3
7.5
9.0
10.7

"
0.9
0.9
1.0
1.1

1.4
"
"
"
"

1.8
"
"
"
"

1.8
"
"
"
1.9

1.8
"
"
1.9
2.0

11
12
13
15
16

19
22
24
27
31

20
24
26
29
33

22
26
29
32
37

230
330
430
550
760

530
760
1,000
1,280
1,760

700
1,020
1,350
1,750
2,430

880
1,300
1,680
2,220
3,120

95
120
150
185
240

12.5
14.0
15.8
17.5
20.2

1.1
1.2
1.4
1.6
1.7

1.5
1.5
1.6
1.6
1.7

2.0
2.1
2.2
2.3
2.5

2.0
2.1
2.3
2.4
2.6

2.1
2.3
2.4
2.6
2.8

19
20
22
24
27

34
38
42
46
51

37
41
45
50
55

41
45
50
55
62

1,030
1,270
1,560
1,920
2,540

2,330
2,920
3,550
4,400
5,580

3,250
4,030
4,950
6,150
7,960

4,190
5,210
6,380
7,970
10,320

300
400
500
630

22.5
26.1
28.8
33.0

1.8
2.0
2.2
2.4

1.8
1.9
2.0
2.2

2.7
2.9
3.1
-

2.8
3.0
3.3
-

3.0
3.3
3.5
-

29
33
37
42

57
63
-

61
68
-

68
76
-

3,080
3,920
5,110
6,680

7,020
8,960
-

9,890
12,600
-

12,820
16,400
-

Construction/Kt cu

1. Conductor/Li dn in

: Copper/ng

2. Fire proof/Lp chng chy

: Special mica tape

3. Insulation/Lp cch in

: XLPE

Applied spec.:
Tiu chun p dng
Iec 60502
IEC 60331/BS 6387

4. Filler/Lp n
5. Outer sheath/V bc ngoi

: FR-PVC or LSHF

LSHF: Low Smoke Halogen Free Fire resistant

0.6/1 kv fire resistant cable


Cp chng chy 0.6/1 kV
IEC 60331/BS 6387

Single core armoured XLPE cable - Cp n pha c gip


Nom. Crosssectional area

Diameter of
conductor

Thickness of
insulation

Diameter of
amour wire

Thickness of outer
sheath

Approx. overall
diameter

Tit din
danh nh

ng knh
li dn

Chiu dy
cch in

ng knh si gip

Chiu dy v bc

ng knh tng

(mm)

(mm)

(mm2)

(mm)

(mm)

6
10

3.12
4.05

0.7
"

0.9
"

1.8
"

13
14

250
290

16
25
35
50
70

5.1
6.3
7.5
9.0
10.7

"
0.9
0.9
1.0
1.1

0.9
"
"
1.25
1.25

1.8
"
"
"
"

14
17
17
19
20

350
490
610
750
985

95
120
150
185
240

12.5
14.0
15.8
17.5
20.2

1.1
1.2
1.4
1.6
1.7

1.25
1.6
1.6
1.6
1.6

1.8
"
"
"
1.9

23
25
28
29
33

1,270
1,650
1,960
2,370
3,030

300
400
500
630

22.5
26.1
28.8
33.0

1.8
2.0
2.2
2.4

1.6
2.0
2.0
2.0

2.0
2.1
2.2
2.3

36
40

3,680
4,760
5,890
7,350

(mm)
Single core - Cp n

Construction/Kt cu

1. Conductor/Li dn in

: Copper/ng

2. Fire proof/Lp chng chy

: Special mica tape

3. Insulation/Lp cch in

: XLPE

4. Inner sheath/Bc lt

: FR-PVC or LSHF

5. Armoured/Gip

: Al. wire/Si nhm

6. Outer sheath/V bc ngoi

: FR-PVC or LSHF

Applied spec. :
Tiu chun p dng
Iec 60502
IEC 60331/BS 6387

LSHF: Low Smoke Halogen Free Fire resistant

45
48

Approx. weight of cable


Khi lng cp
gn ng

(kg/km)

0.6/1 kv Fire resistant cable


Cp chng chy 0.6/1 kV
IEC 60331/BS 6387

Multi-core armoured XLPE cable - Cp XLPE nhiu li c gip


Nominal Diameter Thickness
crossof
of
sectional conductor insulation
area

Armour - Gip
Tape - Bng
Thickness(mm)

Wire - Si
Diameter(mm)

Thickness of
outer sheath

Approx. Overall
diameter

Chiu dy v bc

ng knh tng

ng knh
li dn

Chiu dy
cch in

(mm )

(mm)

(mm)

2c

3c

4c

2c

3c

4c

2c

(mm)
3c

4c

2c

(mm)
3c

4c

1.5
2.5
4
6
10

1.56
2.01
2.55
3.12
4.05

0.7
0.7
0.7
0.7
"

0.2
0.2
0.2

0.2
0.2
0.2

0.2
0.2
0.2
0.2

0.9
0.9
0.9
0.9
"

0.9
0.9
0.9
0.9
"

0.9
0.9
0.9
0.9
"

1.8
1.8
1.8
1.8
"

1.8
1.8
1.8
1.8
"

1.8
1.8
1.8
1.8
"

15.5
16.5
18
19
20

16
17
19
20
21

17
18
20
21
22

16
25
35
50
70

5.1
6.3
7.5
9.0
10.7

"
0.9
0.9
1.0
1.1

0.2

"
"
"

0.2
"
"
"
"

0.2
"
"
"
"

0.9
1.6
1.6
1.6
1.6

0.9
1.6
1.6
1.6
2.0

0.9
1.6
1.6
1.6
2.0

1.8
"
"
"
2.0

1.8
"
"
1.9
2.0

1.8
"
1.9
2.0
2.1

22
27
29
31
35

23
28
30
32
37

95
120
150
185
240

12.5
14.0
15.8
17.5
20.2

1.1
1.2
1.4
1.6
1.7

"
0.5
"
"
"

0.5
"
"
"
"

0.5
"
"
"
"

2.0
"
"
2.5
2.5

2.0
"
2.5
2.5
2.5

2.0
2.5
2.5
2.5
2.5

2.1
2.2
2.3
2.5
2.7

2.2
2.3
2.5
2.6
2.8

2.3
2.5
2.6
2.8
3.0

42
45
47

300
400
500

22.5
26.1
28.8

1.8
2.0
2.2

0.5
"
0.5

0.5
"
0.5

0.5
"
0.8

2.5
2.5
3.15

2.5
2.5
3.15

2.5
2.5
3.15

2.8
3.1
3.3

3.0
3.2
3.5

3.2
3.5
3.8

Tit din
danh nh
2

Chiu dy

ng knh

: Copper/ng

2. Fire proof/Lp chng chy

: Special mica tape

3. Insulation/Lp cch in

: XLPE

5. Inner sheath/Bc lt

: FR-PVC or LSHF

6. Armoured/Gip

: Steel wire or Tape/ Si


hoc Bng thp

7. Outer sheath/V bc ngoi

: FR-PVC or LSHF

LSHF: Low Smoke Halogen Free Fire resistant

2c

(kg/km)
3c

4c

580
720

470
550
660
770
1,020

24
29
32
35
41

870
1,490
1,790
2,170
2,790

1,060
1,770
2,260
2,730
3,800

1,270
2,120
2,660
3,310
4,690

59

43
48
54
58
64

46
52
56
63
69

3,820
4,580
5,410
6,990
8,710

4,850
5,850
7,480
8,990
11,380

5,990
7,820
9,280
11,320
14,232

67
72
80

71
77
89

77
85
97

10,540
12,850
16,750

13,640
16,850
21,940

17,200
22,450
27,770

54

Applied spec. :
Tiu chun p dng
Iec 60502
IEC 60331/BS 6387

4. Filler/Lp n

Khi lng cp
gn ng

450
500
570
670
850

Construction/Kt cu

1. Conductor/Li dn in

Approx. weight of cable

420
460
510

0.6/1 kv fire resistant wire


Dy cp chng chy 0.6/1 kv
IEC 60331/BS 6387

Single insulated wire - Dy bc n


Approx. Overall Approx weight
diameter

Nominal
area

Diameter
of conductor

Thickness
of insulation

Tit din
danh nh

ng knh
li

dy
cch in

ng knh
tng

Khi lng
gn ng

(mm2)

(mm)

(mm)

(mm)

(kg/km)

D.C Cond.
Resistance
at 20oC
in tr DC

( /km)

2.5

2.01 (7/0.67)

0.8

4.4

40

2.55 (7/0.85)

1.0

5.3

62

7.41
4.61

3.12 (7/1.04)

1.0

5.9

82

3.08

10
16(*)

4.05 (7/1.35)
4.7

1.0
1.0

6.8
7.9

122
188

1.83
1.15

25
35
50

5.9
7.0
8.1

1.2
1.2
1.4

9
10
13

275
362
526

0.727
0.524
0.387

70
95
120
150

9.8
12.5
14.0
15.8

1.4
1.6
1.6
1.8

14
17
19
21

725
984
1,320
1,590

0.268
0.193
0.153
0.124

185
240
300
400
500

17.5
20.2
22.5
26.1
28.8

2.0
2.2
2.4
2.6
2.8

23
26
29
33
36

1,910
2,530
3,170
4,190
4,150

0.0991
0.0754
0.0601
0.0470
0.0366

(*) 16mm2 to 500mm2 are compact round or strand(16 mm 2 n 500mm 2 l li nn hoc bn trn)

Construction/Kt cu

1. Conductor/Li dn in

: Copper/ng

2. Fire proof/Lp chng chy

: Special mica tape

3. Outer sheath/V bc ngoi

: FR-PVC or LSHF

Applied spec. :
Tiu chun p dng
Iec 60502
IEC 60331/BS 6387

LSHF: Low Smoke Halogen Free Fire resistant

Flame retardant & LSHF Flame retardant cables

Cp chng bn chy v chng bn chy t khi


Feature :
Flame resistant cables of LS-VINA Cable can prevent spread of fire when fire occur, specially it is areas of an installation,
tunnels, crowded areas...
Low Smoke Halogen Free Flame resistant cable for safety purpose to escape in the event of an emergency.

Applied standards
IEC 60502:
IEC 60332-1:
IEC 60332-3(or BS 4066):
IEC 754-1 & 2 (or BS 6425):
IEC 61034-2 (or BS 7622):

Structure and dimension


Flame retardant (Single vertical)
Flame retardant
Halogen Free Properties
Low Smoke Properties

c im:
Cp chng bn chy ca LS-VINA Cable c c im truyn la chm s cn tr khng cho la lan to khi c chy, c bit l
cc khu vc nhy cm ca cc cng trnh, ng hm, khu ng ngi...
Cp chng bn la t khi v khng c kh Halogen vi mc ch gi an ton d dng thot him khi c ho hon.

Tiu chun p dng


IEC 60502:
IEC 60332-1:
IEC 60332-3(or BS 4066):
IEC 754-1 & 2 (or BS 6425):
IEC 61034-2 (or BS 7622):

Kt cu v kch thc
Chng bn la (n thng ng)
Chng bn la
c tnh Halogen
c tnh t khi

Cables - Cp

Burner - Vi t

Burner - Vi t

Vertical mounted on ladder


B tr mng thng ng

0.6/1 kv flame retardant cable


Cp chng bn chy 0.6/1 kV
IEC 60332/BS 4066

Unarmoured XLPE cable - Cp XLPE khng c gip bo v


Nom. cross- Diameter of Thickness
sectional area conductor of insulation

Thickness of outer
sheath

Approx. overall
diameter

Approx. weight of cable

ng knh
li

Chiu dy v bc

ng knh tng

Khi lng cp gn ng

(mm)

(mm)

Tit din
danh nh
2

(mm )

(mm)

1.5
2.5
4
6
10

Chiu dy
cch in

(kg/km)

(mm)

1c

2c

3c

4c

1c

2c

3c

4c

1c

2c

3c

4c

1.56
2.01
2.55
3.12
4.05

0.7
"
"
"
"

1.4
"
"
"
"

1.8
"
"
"
"

1.8
"
"
"
"

1.8
"
"
"
"

7
7
8
8
9

11
12
13
14
16

12
13
14
15
17

12.5
13.5
15
16
18

50
65
80
110
150

130
170
210
280
370

160
200
260
330
480

180
240
320
420
610

16
25
35
50
70

5.1
6.3
7.5
9.0
10.7

"
0.9
0.9
1.0
1.1

1.4
"
"
"
"

1.8
"
"
"
"

1.8
"
"
"
1.9

1.8
"
"
1.9
2.0

10
11
12
14
16

17
21
23
26
29

18
22
24
27
32

20
24
27
30
35

210
310
410
540
750

500
730
960
1,250
1,730

660
990
1,350
1,710
2,400

830
1,260
1,660
2,210
3,210

95
120
150
185
240

12.5
14.0
15.8
17.5
20.2

1.1
1.2
1.4
1.6
1.7

1.5
1.5
1.6
1.6
1.7

2.0
2.1
2.2
2.3
2.5

2.0
2.1
2.3
2.4
2.6

2.1
2.3
2.4
2.6
2.8

18
19
21
23
26

33
37
41
45
51

36
39
44
49
55

39
44
49
54
61

1,010
1,270
1,560
1,940
2,540

2,330
2,920
3,580
4,450
5,850

3,220
4,060
5,020
6,230
8,200

4,210
5,300
6,530
8,170
10,710

300
400
500
630

22.5
26.1
28.8
33.0

1.8
2.0
2.2
2.4

1.8
1.9
2.0
2.2

2.7
2.9
3.1
-

2.8
3.0
3.3
-

3.0
3.3
3.5
-

29
32
36
42

57
63
71
-

61
68
76
-

68
76
85
-

3,160
4,010
5,110
6,680

7,270
9,170
11,680

10,200
12,890
16,530

13,320
17,000
21,680

Construction/Kt cu

1. Conductor/Li dn in

: Copper/ng

2. Insulation/Lp cch in

: XLPE

Applied spec. :
Tiu chun p dng
Iec 60502
IEC 60332/BS 4066

3. Filler/Lp n
4. Outer sheath/V bc ngoi

: FR-PVC or LSHF

LSHF: Low Smoke Halogen Free Flame retardant

10

0.6/1 kv flame retardant cable


Cp chng bn chy 0.6/1 kV
IEC 60332/BS 4066

Single core armoured XLPE cable - Cp XLPE n pha c gip


Nom. crosssectional area

Diameter of
conductor

Thickness of
insulation

Diameter of
armour wire

Thickness of outer
sheath

Approx. overall
diameter

Tit din
danh nh

ng knh
li dn

Chiu dy
cch in

ng knh si gip

Chiu dy v bc

ng knh tng

Khi lng cp
gn ng

(mm)

(mm)

(mm)

(kg/km)

(mm2)

(mm)

(mm)

6
10

3.12
4.05

0.7
"

0.9
"

1.8
"

12
13

240
280

16
25
35
50
70

5.1
6.3
7.5
9.0
10.7

"
0.9
0.9
1.0
1.1

0.9
"
"
"
"

1.8
"
"
"
"

14
16
17
18
20

340
470
580
720
960

95
120
150
185
240

12.5
14.0
15.8
17.5
20.2

1.1
1.2
1.4
1.6
1.7

0.9
1.6
1.6
1.6
1.6

1.8
"
"
"
1.9

22
25
27
29
32

1,230
1,610
1,920
2,330
2,980

300
400
500
630

22.5
26.1
28.8
33.0

1.8
2.0
2.2
2.4

1.6
2.0
2.0
2.0

2.0
2.1
2.2
2.3

34
39
43
46

3,630
4,670
5,780
7,230

Approx. weight of cable

Single core

Construction/Kt cu

1. Conductor/Li dn in

: Copper/ng

2. Insulation/Lp cch in

: XLPE

3. Inner sheath/Bc lt

: FR-PVC or LSHF

4. Armoured/Gip

: Al. wire/Si nhm

5. Outer sheath/V bc ngoi

: FR-PVC or LSHF

Applied spec. :
Tiu chun p dng
Iec 60502
IEC 60332/BS 4066

LSHF: Low Smoke Halogen Free Flame retardant

11

0.6/1 kv flame retardant cable


Cp chng bn chy 0.6/1 kV
IEC 60332/BS 4066

Multi-core armoured XLPE cable - Cp XLPE nhiu li c gip


Nominal Diameter Thickness
crossof
of
sectional conductor insulation
area
Tit din
danh nh

ng knh
li dn

Chiu dy
cch in

(mm2)

(mm)

(mm)

1.5
2.5
4
6
10

1.56
2.01
2.55
3.12
4.05

0.7
0.7
0.7
0.7
0.7

16
25
35
50
70

5.1
6.3
7.5
9.0
10.7

"
0.9
0.9
1.0
1.1

95
120
150
185
240

12.5
14.0
15.8
17.5
20.2

300
400
500

22.5
26.1
28.8

Armour - Gip
Tape - Bng
Thickness(mm)

Wire - Si
Diameter(mm)

Thickness of
outer sheath

Approx. Overall
diameter

Chiu dy v bc

ng knh tng

Approx. weight of cable


Khi lng cp
gn ng

3c

4c

2c

3c

4c

2c

(mm)
3c

4c

2c

(mm)
3c

4c

2c

0.2
0.2

0.2
0.2

0.9
0.9
0.9
0.9
0.9

0.9
0.9
0.9
0.9
0.9

0.9
0.9
0.9
0.9
0.9

1.8
"
"
"
1.8

1.8
"
"
1.8
1.8

1.8
"
1.8
1.8
1.8

14.5
15.5
16
17
20

15
16
17
18
21

16
17
18
19
22

350
410
470
570
710

350
450
530
660
830

420
500
610
760
990

0.2
"
"
"
"

0.2
"
"
"
"

0.2
"
"
"
"

0.9
1.6
1.6
1.6
1.6

0.9
1.6
1.6
1.6
2.0

0.9
1.6
1.6
1.6
2.0

1.8
"
"
"
2.0

1.8
"
"
1.9
2.0

1.8
"
1.9
2.0
2.1

21
26
28
31
35

22
27
30
32
37

24
29
32
35
41

850
1,460
1,750
2,130
2,760

1,040
1,740
2,220
2,660
3,750

1,240
2,090
2,600
3,260
4,640

1.1
1.2
1.4
1.6
1.7

"
0.5
"
"
"

0.5
"
"
"
"

0.5
"
"
"
"

2.0
"
"
2.5
2.5

2.0
"
2.5
2.5
2.5

2.0
2.5
2.5
2.5
2.5

2.1
2.2
2.3
2.5
2.7

2.2
2.3
2.5
2.6
2.8

2.3
2.5
2.6
2.8
3.0

40
43
47
53
59

42
46
52
56
63

46
52
56
62
69

3,770
4,530
5,350
6,940
8,640

4,800
5,790
7,420
8,920

5,940
7,760
9,220

11,180

11,120
14,132

1.8
2.0
2.2

0.5
"
0.5

0.5
"
0.5

0.5
"
0.8

2.5
2.5
3.15

2.5
2.5
3.15

2.5
2.5
3.15

2.8
3.1
3.3

3.0
3.2
3.5

3.2
3.5
3.8

65
71
80

69
76
86

76
85
96

10,440
12,740
16,650

13,540
16,700
21,820

17,050
22,340
27,670

Chiu dy

2c
0.2
0.2

ng knh

Construction/Kt cu

1. Conductor/Li dn in

: Copper/ng

2. Insulation/Lp cch in

: XLPE

Applied spec. :
Tiu chun p dng
Iec 60502
IEC 60332/BS 4066

3. Filler/Lp n
4. Inner sheath/Bc lt

: FR-PVC or LSHF

5. Armoured/Gip

: Steel wire or Tape/


Si hoc Bng thp

6. Outer sheath/V bc ngoi : FR-PVC or LSHF

LSHF: Low Smoke Halogen Free Flame retardant

12

(kg/km)
3c

4c

0.6/1 kv flame retardant wire


Dy cp chng bn chy 0.6/1 kv
IEC 60332/BS 4066

Reference spec. : iec 60502, IEC 60332, BS 4066


1. Conductor: Copper
Li dn in
2. Sheath insulation: FR-PVC/LSHF
Lp v cch in

LSHF: Low Smoke Halogen Free Flame retardant

Single insulated wire - Dy bc n


Approx weight

D.C Cond. Resistance at 20oC

Khi lng gn ng

in tr DC

Nominal
area

Diameter
of conductor

Thickness
of insulation

Approx.
overall diameter

Tit din
danh nh

ng knh
li

dy
cch in

ng knh
tng

(mm2)

(mm)

(mm)

(mm)

1.5
2.5
4
6

1.56 (7/0.52)
2.01 (7/0.67)
2.55 (7/0.85)
3.12 (7/1.04)

0.8
0.8
1.0
1.0

3.4
3.8
4.8
5.3

23
34
54
75

12.1
7.41
4.61
3.08

10
16 (*)
25
35
50

4.05 (7/1.35)
4.7
5.9
7.0
8.1

1.0
1.0
1.2
1.2
1.4

6.3
7.3
9
10
12

110
175
260
360
510

1.83
1.15
0.727
0.524
0.387

70
95
120
150

9.8
12.5
14.0
15.8

1.4
1.6
1.6
1.8

14
16
18
20

700
960
1,190
1,500

0.268
0.193
0.153
0.124

185
240
300
400
500

17.5
20.2
22.5
26.1
28.8

2.0
2.2
2.4
2.6
2.8

22
25
28
32
35

1,850
2,450
3,040
4,070
4,800

0.0991
0.0754
0.0601
0.0470
0.0366

(*) 16mm2 to 500mm2 are compact round or strand(16 mm 2 n 500mm 2 l li nn hoc bn trn)

13

(kg/km)
Cu conductor

( /km)
Cu conductor

Li ng

Li ng

0.6/1 kv flame retardant cable


cp chng bn chy 0.6/1 kv
IEC 60332/BS 4066

Control cable - Cp iu khin


No. of
Cores
S li

Nom. area

Structure

Diameter

Tit din

Kt cu

ng knh

dy
cch in

(mm2)

(No/mm)

(mm)

(mm)

1.5
2

Insulation
thickness

Conductor - Li dn

7/ 0.52

1.56

0.8

ng knh ngoi

D.C Cond.
Resistance
at 20oC

Insulation
Resistance
at 20oC

(mm)

in tr DC

in tr
cch in

Sheath thickness

Approx. Overall Dia.

dy v bc

(mm)
CVV*
CVV-S*
1.5

1.5

CVV*

CVV-S*

( /km)

(M. /Km)

10.0

10.5

12.1

50

Approx. weight
Khi lng cp
gn ng

(kg/km)
CVV
CVV-S
125

140

7/ 0.6

1.8

0.8

1.5

1.5

10.5

11.0

9.24

50

130

160

2.5

7/ 0.67

2.01

0.8

1.5

1.5

11.0

12.0

7.41

50

150

180

3.5

7/ 0.8

2.4

0.8

1.5

1.5

11.5

12.5

5.20

50

180

210

5.5

7/ 1.0

3.0

1.0

1.5

1.5

13.5

14.5

3.33

50

250

270

7/ 1.2

3.6

1.2

1.5

1.5

15.5

16.5

2.31

50

340

385

1.5

7/ 0.52

1.56

0.8

1.5

1.5

10.5

11.0

12.1

50

135

160

7/ 0.6

1.8

0.8

1.5

1.5

11.0

11.5

9.24

50

160

190

2.5

7/ 0.67

2.01

0.8

1.5

1.5

12.0

12.5

7.41

50

190

220

3.5

7/ 0.8

2.4

0.8

1.5

1.5

12.5

13.0

5.20

50

225

240

5.5

7/ 1.0

3.0

1.0

1.5

1.5

14.5

15.0

3.33

50

320

360

7/ 1.2

3.6

1.2

1.5

1.5

16.5

17.5

2.31

50

440

485

1.5

7/ 0.52

1.56

0.8

1.5

1.5

11.0

11.5

12.1

50

165

190

7/ 0.6

1.8

0.8

1.5

1.5

12.0

12.5

9.24

50

200

230

2.5

7/ 0.67

2.01

0.8

1.5

1.5

12.5

13.5

7.41

50

235

260

3.5

7/ 0.8

2.4

0.8

1.5

1.5

13.5

14.0

5.20

50

280

315

5.5

7/ 1.0

3.0

1.0

1.5

1.5

16.0

16.5

3.33

50

405

450

7/ 1.2

3.6

1.2

1.5

1.5

18.0

18.5

2.31

50

550

585

1.5

7/ 0.52

1.56

0.8

1.5

1.5

12.5

13.0

12.1

50

200

230

7/ 0.6

1.8

0.8

1.5

1.5

13.0

13.5

9.24

50

240

270

2.5

7/ 0.67

2.01

0.8

1.5

1.5

14.0

14.5

7.41

50

280

325

3.5

7/ 0.8

2.4

0.8

1.5

1.5

14.5

15.0

5.20

50

340

365

5.5

7/ 1.0

3.0

1.0

1.5

1.5

17.0

17.5

3.33

50

490

530

7/ 1.2

3.6

1.2

1.5

1.5

20.0

21.0

2.31

50

685

370

1.5

7/ 0.52

1.56

0.8

1.5

1.5

13.5

14.0

12.1

50

210

245

7/ 0.6

1.8

0.8

1.5

1.5

14.0

14.5

9.24

50

280

310

2.5

7/ 0.67

2.01

0.8

1.5

1.5

15.0

15.5

7.41

50

330

360

3.5

7/ 0.8

2.4

0.8

1.5

1.5

15.5

16.5

5.20

50

400

435

5.5

7/ 1.0

3.0

1.0

1.5

1.5

18.5

19.5

3.33

50

590

630

7/ 1.2

3.6

1.2

1.5

1.5

22.0

23.0

2.31

50

810

850

(*) CVV: Copper conductor, PVC insulated, PVC Sheath


CVV-S: Copper conductor, PVC insulated, PVC Sheath with coper shield

Construction/Kt cu

1. Conductor/Li dn in

: Copper/ng

2. Insulation/Lp cch in

: XLPE

Applied spec. :
Tiu chun p dng
Iec 60502
IEC 60332/BS 4066

3. Filler/Lp n
4. Outer sheath/V bc ngoi

: FR-PVC or LSHF

LSHF: Low Smoke Halogen Free Flame retardant


14

0.6 kv flame retardant cable


Dy cp chng bn chy 0.6 kv
IEC 60332/BS 4066

Control cable - Cp iu khin


Conductor - Li dn

No. of
Cores
S li

Nom. area

Structure

Diameter

Tit din

Kt cu

ng knh

dy
cch in

(No/mm)

(mm)

(mm)

(mm )

10

12

15

20

30

37

Insulation
thickness

Sheath thickness

Approx. Overall Dia.

dy v bc

ng knh ngoi

(mm)
CVV*
CVV-S*

(mm)
CVV*
CVV-S*

D.C Cond.
Resistance
at 20oC

Insulation
Resistance
at 20oC

in tr DC

in tr
cch in

( /km)

(M. /Km)

Approx. weight
Khi lng cp
gn ng

(kg/km)
CVV
CVV-S

1.5

7/ 0.52

1.56

0.8

1.5

1.5

13.5

14.0

12.1

50

250

285

7/ 0.60

1.8

0.8

1.5

1.5

14.0

14.5

9.24

50

300

335

2.5

7/ 0.67

2.01

0.8

1.5

1.5

15.0

15.5

7.41

50

355

390

3.5

7/ 0.80

2.4

0.8

1.5

1.5

15.5

16.5

5.20

50

430

475

5.5

7/ 1.00

3.0

1.0

1.5

1.5

18.5

19.5

3.33

50

640

690

7/ 1.20

3.6

1.2

1.5

1.5

22.0

23.0

2.31

50

900

980

1.5

7/ 0.52

1.56

0.8

1.5

1.5

14.5

15.0

12.1

50

280

320

7/ 0.60

1.8

0.8

1.5

1.5

15.0

15.5

9.24

50

340

375

2.5

7/ 0.67

2.01

0.8

1.5

1.5

16.5

17.0

7.41

50

410

445

3.5

7/ 0.80

2.4

0.8

1.5

1.5

17.0

17.5

5.20

50

500

535

5.5

7/ 1.00

3.0

1.0

1.5

1.5

21.0

21.5

3.33

50

730

780
1,120

7/ 1.20

3.6

1.2

1.6

1.6

24.0

24.5

2.31

50

1,040

1.5

7/ 0.52

1.56

0.8

1.5

1.5

16.5

17.0

12.1

50

355

400

7/ 0.60

1.8

0.8

1.5

1.5

17.5

18.0

9.24

50

430

465

2.5

7/ 0.67

2.01

0.8

1.5

1.5

18.5

19.0

7.41

50

485

520

3.5

7/ 0.80

2.4

0.8

1.5

1.5

19.5

21.0

5.20

50

630

675

5.5

7/ 1.00

3.0

1.0

1.6

1.6

24.0

25.0

3.33

50

940

995
1,400

7/ 1.20

3.6

1.2

1.8

1.8

29.0

29.5

2.31

50

1,360

1.5

7/ 0.52

1.56

0.8

1.5

1.5

17.5

18.0

12.1

50

410

455

7/ 0.60

1.8

0.8

1.5

1.5

18.0

18.5

9.24

50

490

530

2.5

7/ 0.67

2.01

0.8

1.5

1.5

19.5

20.0

7.41

50

545

595

3.5

7/ 0.80

2.4

0.8

1.5

1.5

21.0

21.5

5.20

50

720

765

5.5

7/ 1.00

3.0

1.0

1.7

1.7

25.0

26.0

3.33

50

1,100

1,160
1,820

7/1.20

3.6

1.2

1.8

1.8

30.0

30.5

2.31

50

1,560

1.5

7/ 0.52

1.56

0.8

1.5

1.5

18.5

19.0

12.1

50

485

540

7/ 0.60

1.8

0.8

1.5

1.5

19.0

19.5

9.24

50

575

630

2.5

7/ 0.67

2.01

0.8

1.5

1.5

21.5

22.0

7.41

50

650

700

3.5

7/ 0.80

2.4

0.8

1.5

1.6

22.0

23.0

5.20

50

855

930

5.5

7/ 1.00

3.0

1.0

1.7

1.8

27.0

28.0

3.33

50

1,310

1,400

1.5

7/ 0.52

1.56

0.8

1.5

1.5

21.0

21.5

12.1

50

620

680

7/ 0.60

1.8

0.8

1.5

1.5

22.0

22.5

9.24

50

735

790

2.5

7/ 0.67

2.01

0.8

1.6

1.6

24.0

24.5

7.41

50

875

930

3.5

7/ 0.80

2.4

0.8

1.6

1.6

25.0

25.5

5.20

50

1,130

1,190

5.5

7/ 1.00

3.0

1.0

1.9

1.9

31.0

31.5

3.33

50

1,730

1,800

1.5

7/ 0.52

1.56

0.8

1.6

1.6

24.5

25.0

12.1

50

880

955

7/ 0.60

1.8

0.8

1.7

1.7

26.0

27.0

9.24

50

1,100

1,140

2.5

7/ 0.67

2.01

0.8

1.7

1.7

28.0

29.0

7.41

50

1,250

1,300

3.5

7/ 0.80

2.4

0.8

1.8

1.8

30.0

31.0

5.20

50

1,670

1,730

1.5

7/ 0.52

1.56

0.8

1.6

1.6

26.5

27.0

12.1

50

1,060

1,140

7/ 0.60

1.8

0.8

1.7

1.7

29.5

30.0

9.24

50

1,300

1,390

2.5

7/ 0.67

2.01

0.8

1.8

1.8

30.0

31.0

7.41

50

1,510

1,600

3.5

7/ 0.80

2.4

0.8

2.0

2.0

36.0

37.0

5.20

50

2,160

2,280

(*) CVV: Copper conductor, PVC insulated, PVC Sheath


CVV-S: Copper conductor, PVC insulated, PVC Sheath with coper shield

15

Comparison between Flame retardant cables and Normal cables


So snh cp chng bn chy v cp thng

Flame retardant cables


Cp chng bn chy

Normal cables
Cp thng

10 min.