Technical Data 50/60 Hz

Vertical multi-stage centrifugal pumps


serie: DPV 85

Table of Contents
1

Pump introduction
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
1.13

Performance characteristics
2.1
2.2
2.3
2.4
2.5

DPV(C/S)F 85 50 Hz, with 2 pole motor ~2900 rpm ............................................................................ 14


DPV(C/S)F 85 50 Hz, with 4 pole motor ~1450 rpm ............................................................................ 16
DPV(C/S)F 85 60 Hz, with 2 pole motor ~3500 rpm ............................................................................ 18
DPV(C/S)F 85 60 Hz, with 4 pole motor ~1750 rpm ............................................................................ 20
DPV(C/S)F 85 50 Hz, 2 pole without motor @ 2900 rpm (IEC) ........................................................... 22
DPV(C/S)F 85 50 Hz, 4 pole without motor @ 1450 rpm (IEC) ........................................................... 24
DPV(C/S)F 85 60 Hz, 2 pole without motor @ 3500 rpm (IEC) ........................................................... 26
DPV(C/S)F 85 60 Hz, 4 pole without motor @ 1750 rpm (IEC) ........................................................... 28
Sealing ................................................................................................................................................. 30
Connection........................................................................................................................................... 34
Motor options ....................................................................................................................................... 35

Article numbers
4.1
4.2
4.3
4.4
4.5
4.6

Performance curve details ....................................................................................................................11


Performance with variable frequency drive.......................................................................................... 12
Performance using other brand of motors ........................................................................................... 12
Divergent speed calculation................................................................................................................. 12
How to read the values from the curves .............................................................................................. 13

Technical specifications
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11

Model key............................................................................................................................................... 3
Description of the product ...................................................................................................................... 3
Basic material variants ........................................................................................................................... 3
Pump bearing......................................................................................................................................... 3
Working range........................................................................................................................................ 3
Motor...................................................................................................................................................... 4
Mechanical shaft seal ............................................................................................................................ 5
Modular built-up ..................................................................................................................................... 5
Approvals ............................................................................................................................................... 5
Operation ............................................................................................................................................... 6
Measuring, draining and venting............................................................................................................ 6
Standard construction ............................................................................................................................ 6
Parts overview ....................................................................................................................................... 8

DPVCF 85 50 Hz 2900 rpm ................................................................................................................. 36


DPVF 85 50 Hz 2900 rpm.................................................................................................................... 37
DPVSF 85 50 Hz 2900 rpm ................................................................................................................. 38
DPVCF 85 60 Hz 3500 rpm ................................................................................................................. 39
DPVF 85 60 Hz 3500 rpm.................................................................................................................... 40
DPVSF 85 60 Hz 3500 rpm ................................................................................................................. 41

Chemical resistance
5.1

Chemical resistance............................................................................................................................. 42

Pump introduction

1.1

Model key

Table 1: Model key DPV(S)F 85 /5-1


DP

VS

DP

DP

VS

all wetted parts 1.4408 (AISI 316)

DP

VC

Pump bracket and motor stool lower JL1040 (GG25), Hydraulics 1.4308
(AISI 304)

DP

DP

DP

DP

1.2

85

/5

-1

Pump type
Material code

F
85

all wetted parts 1.4308 (AISI 304)

Connection code

Round flange DIN, ASME, JIS / PN16, PN25/40

Pump size

Indicates the optimum capacity in m3/h at 50 Hz.

/5

Number of impeller / diffuser stages


-1

Upper stage with reduced head impeller(s) (at upper stage(s))

Description of the product

The vertical, single or multi stage centrifugal pump


series are designed for pumping clean, or lightly
aggressive, watery mediums.
Suction and discharge of the pump are in-line,
making the pump easy to install.
The hydraulic assembly is driven by an electric motor.
All hydraulic parts of the pump are made of stainless
steel.

1.3

Basic material variants

Table 2: Basic material variants


Hydraulic

Casings

VC

1.4308

JL1040

EPDM

1.4308

1.4308

EPDM

VS

1.4408

1.4408

Viton

Pump bearing

Medium lubricated stage bearing


Tungsten carbide against ceramic

Working range

The working range is depending on the application


and a combination of pressure and temperature For
specific and detailed limits advice the working ranges
are described in the chapter Modules. The overall
working range of the pumps can be summarised as
follows:
Table 3: Specification of the working range
Pump type

DPV

Sealings

note

Ambient temperature [C]

-30 up to 40

medium temperature [C]

-30 up to 140

40

Maximum working pressure


[bar]
Minimum inlet pressure

Model

1.4

1.5

Maximum inlet pressure


[bar]
Viscosity [cSt]
3

Density [kg/m ]
Cooling

NPSHreq. + 1m
40 - pump pressure
1-100

1000-2500

forced motor cooling

Minimum frequency [Hz]

10

Maximum frequency [Hz]

60

Nominal flow (Qopt.) [m /h]

85 (50 Hz -2 pole)
102 (60 Hz -2 pole)

Maximum flow [m3/h]

112.8 (50 Hz -2 pole)


135 (60 Hz -2 pole)

Pump type

DPV

Efficiency (% at Qopt.)

81

NPSHreq.(m at Qopt.)

2.9

Maximum motor power


[kW]

45

Maximum Pump pressure


[m]

176 (50 Hz -2 pole)


151 (60 Hz -2 pole)

Allowable size of solids


pumped

5m to 1mm

1.

1.6

note

If the ambient temperature exceeds the above value or


the motor is located more than 1000 m above sea
level, the motor cooling is less effective and could
require an adapted motor power. See table 9: Motor
load dep. sea level or amb. temp or please contact
your supplier for more detailed advice.

2.

High temperature or high pressure could require a


special pump selection, see 3.9: Sealing.

3.

Deviation in viscosity and/or density could require an


adapted motor power. Please contact your supplier for
more detailed advice.

4.

The free space above the motor cooling fan must be at


least 1/4 of the diameter of the inlet of the cooling fan
in order to have a sufficient flow of (cooling) air.

5.

Pumps that are intended for 50 Hz operation, may not


be connected to 60 Hz power supply.

Standard DP Electromotor, T.E.F.C., IP55 class F


three phase A.C. squirrel cage induction motors rated
for 400 V-line 50 and 60 Hz, duty class S1, provided
with PTC. Main dimensions acc. IEC, 2 pole 30, 37
and 45 kW efficiency class EFF1. 5.5 kW - 22 kW
improved efficiency class EFF 2 (see table 6 motor
efficiency.)
Options:
4 pole (see 4 pole pump curves)
Other motor brands
ATEX classification Eex e II T3 or Eex d IIc T4
Without motor, optionally with thrust bearing
housing (see table 7 Minimum required motor
Driver -end bearing)
Efficiency class 1 (EFF 1)
Rain cover
Insulation class IP56
Anti condensation heater
Industrial connection (Harting stecker)
Note: motor options can be combined as packages
Table 6: motor efficiency.

20 oC

For minimum flow at medium temperature of


see table 4 Minimum capacity (Qmin); for higher
temperatures see table 5 Minimum capacity vstemperature (Q) (in % of Q optimum)

Classification

Table 4: Minimum capacity (Qmin)


Qmin [m3/h]

size

50 Hz - 2 pole
85

60 Hz - 2 pole

8.5

Motor

10.2

Table 5: Minimum capacity vs-temperature (Q) (in %


of Q optimum)

Standard
DP motor

Classifica- Standard
tion
DP motor

kW

EFF 2

EFF 2

EFF 1

EFF 1

5.5

85.7%

86.0%

88.6%

88.6%

7.5

87.0%

86.8%

89.5%

89.5%

11

88.4%

90.0%

90.5%

90.5%

15

89.4%

91.0%

91.3%

91.3%

18.5

90%

90.9%

91.8%

91.8%

22

90.5%

90.6%

92.2%

92.2%

30

92.9%

92.9%

37

93.3%

93.7%

45

93.7%

94.7%

ID 2312/29072004

Q [%]

30

Table 7: Minimum required motor Driver-end bearing

25
20

10
5
0
40

50

60

70

80

90

100

110
t [C]

120

2312/29072004

15

kW

Axial bearing

kW

Co-axial bearing

5.5

6308-2Z-C3

11

7309-BEP

7.5

6308-2Z-C3

15

7309-BEP

18.5

7309-BEP

22

7311-BEP

30

7312-BEP

37

7312-BEP

45

7314-BEP

Table 8: Motor load vs. sea level or amb. temp.


Motor load

20

1000

100%

25

1000

100%

30

1000

100%

35

1000

100%

40

1000

100%

45

1625

98%

50

2250

95%

55

2875

90%

60

3500

85%

65

4125

80%

70

4750

75%

ID3028

ID3029

cartridge

1.8

amb temp-level-motorload

Table 9: Motor load dep. sea level or amb. temp.

20080545/170608

Above see
level [m]

20080544/170608

Ambient temp.
[C]

easy access

Modular built-up

To suit almost every application the pump is built-up


out of modules which can be selected depending on
the required working range.
Basic modules are:

ID 3053/19022008

3053/19022008

1.7

Mechanical shaft seal

Single acting mechanical seal acc. EN 12756.


Exchangeable without disassembling the pump and
removing the motor.
Standard in Easy access construction for
applications with a medium/long expected life span of
the mechanical seal.
Optionally as Cartridge available for applications on
which a short life span of the mechanical seal is to be
expected.

Basic pump model, which defines the capacity,


pressure and basic material
Connections, which defines the suction and
discharge connection as well as the base plate.
Sealings, which defines the elastomers, the
mechanical seal and the shaft seal type.
Electric motor, which defines all requirements
of the motor such as motor size, power, voltage,
frequency and all possible motor accessories.
For detailed selection, see 3.11 Motor options.

1.9
CE
ACS
WRc
ATEX

Approvals
Conformity with European Safety Directive
Drinking Water Approval (F)
Drinking Water Approval (GB)
Conformity with ATmosphres EXplosibles
Directive

1.10

Operation

At the centrifugal operation of the pump an


underpressure is created at the inlet of the impeller.
This underpressure enables the medium to enter the
pump at the suction connection (A).
Every stage (B) consists of an impeller and diffuser
The passage of this stage determines the capacity of
the pump. The stages diameter is related to the
centrifugal forces and its stage pressure: the more
stages, the more pressure.
This total capacity and built-up pressure will be
guided to the outside of the pump, between the pump
stages and the outer sleeve (C) and the medium will
leave the pump at the discharge connection (D).

ID3027

1.11

The pump is provided with plugs for measuring,


draining and venting.
Connection (E) is meant to drain the inlet part of the
pump. Or to measure the inlet / suction pressure
using a G connection.
Connection (F) is meant to drain the outlet part of the
pump. Or to measure the discharge pressure using a
G connection.
Connections (G) are meant to vent the pump system
when the pump is not in operatio. Or to measure the
discharge pressure of the pump using a G 3/8
connection.

1.12

6
E

20080190-A/27022008

Measuring, draining and


venting

Standard construction

Vertical multi stage centrifugal pump


Vertical multi stage inline
-30 oC up to 140 oC
Pressure class PN 40
Multiple models to suit the application

Other brand and/or standard motors can be


fit to the pump using an additional thrust
bearing housing.

Easy air relieve and pressure measuring


plugs 1/4 for fast passing.
Two separate plugs for air relief and/or
measuring purposes.
Multiple-use O-ring sealings.

Durable shaft seal, exchangeable without


pump dismantling
Easy access version, optionally in cartridge
version
Wide range of elastomer and seal face
material variants.

Stainless materials for all wetted parts like


impeller, diffuser, shaft and shroud.
Pump casings are stainless steel or
cataphoretic coated cast iron.

Rigid construction
Stainless steel reinforced shroud
High pressure resistant exterior.

Rigid inline pump casing for easy piping and


installation
DPV and DPVS with cast iron collar flanges,
optionally in stainless steel, matching with
DIN, ASME and JIS.

Clever plugs for draining and measuring


Separate measuring of inlet and outlet
pressure (delta P)
100% Draining (non residual)
By-pass possibilities
Multiple-use O-ring sealings.

Heavy duty base plate, powder coated 100


m
optionally in stainless steel
Lay-out of pump mounting holes
interchangeable with other brands.

20080470-A/04072008

ID3226

Long life time electromotor


Multi range Voltage / Frequency
Enclosure IP55
Insulation class F
Improved Efficiency
Temp. monitoring PTC.

1.13

Parts overview

1.13.1

Sectional drawing DPV(S)F 85

20080066-D/22072008

ID3239

1.13.2

Part list

Part. no.

part description

material code

Wetted
part

VC

101

Pump casing

JL1040

1.4308

1.4408

(Collar) flange

z
z

JS1030

1.4308
Pump shroud

1.4404

160

Cover

1.4308

1.4408

108

Stage Casing DPV 85

1.4308

1.4408

108

Stage Casing DPV 2,4,6

1.4301

1.4404

210

Shaft

1.4057

1.4460

230

Impeller DPV 85

1.4308

1.4408

230

Impeller DPV 2,4,6

1.4301

1.4404

412

Pump sealing elastomers

EPDM

z
z
z
z

EPDM WRc/ACS

Viton

EPDM E425

HNBR

B Q 1 E GG LP

Q1 B E GG HP1

B Q1 V GG LP

Q1 B V GG HP1

Others

See 3.9 Sealing

Spacer V(C/S) 85

EPDM

Viton

HNBR

Shaft seal LP (P at Q=0 < 9.2bar)


Shaft seal LP (P at Q=0 < 9.2bar)

45-4

z
{

10-6

433

1.4301

VS

z
z
z
z
z

525

Spacer sleeve

1.4301
1.4404

529

Bearing sleeve

Tungsten Carbide

Part of 108

Bearing

Aluminium Oxide

862

Coupling

JS1030

890

Base plate

JL1040

1.4308

903.02

Screwed plug (drain)

1.4301 (A2)

905

Tie bolt

1.4404 (A4)
1.4057

903.01

Screwed plug (vent)

1.4301 (A2)

1.4404 (A4)

z
z
z

Part. no.

part description

material code

Wetted
part

VC

920.02

Nut

1.4301

1.4404

VS

932

Circlip

1.4571

950

Wave spring V(C/S) 2/4/6

1.4301

1.4401

1.

HP: high pressure version > 10 bar (P at Q=0 > 9.2 bar)

z Standard{ Option

1.13.3

Materials conversion

Material

Description

JL 1040
JS1030

GJL-250
GJS-400

Standard

ASTM / AISI1

EN 1561

A48:40B

EN 1563

1.4057

Chromium-nickel steel

X17CrNi16-2--QT800

EN 10088-3

A276:431

1.4301

Chromium-nickel steel

X5CrNi18-10

EN 10088

A276:304

1.4305

Chromium-nickel steel

X8CrNiS 18-9

EN 10088

A276:303

1.4308

Chromium-nickel cast steel

GX5CrNi 19-10

EN 10283

A743:CF8

1.4401

Chromium-nickel-molybdenum steel

X5CrNiMo 17-12-2

EN 10088

A276:316

1.4404

Chromium-nickel-molybdenum steel

X2CrNiMo 17-12-2

EN 10088

A276:316L

EN 10213

A743CF8M

1.4408
1.4460
1.4571
1.

10

Cast iron
Cast iron

Code and material nr.

Chromium-nickel-molybdenum cast steel


Chromium-nickel-molybdenum steel
Chromium-nickel-molybdenum steel

GX5CrNiMo 19-11-2
X3CrNiMoN 27 5 2
X6CrNiMoTi17-12-2

Note: The indication of the material designations to ASTM / AISI is not binding

EN 10088
EN 10088

A276:316Ti

Performance characteristics

2.1

Performance curve details

The collective diagrams give a global overview of all


pump models mentioned in this documentation.
Detailed characteristics are given for each model
showing the hydraulic efficiency, NPSHreq, and shaft
power per stage.
The performance of the pump depends on the
number of stages. The number of stages are shown
as /3 , as per example:
DPVF 85/3: 3 full stages
DPVF 85/3-1: 2 full stages, 1 stage with reduced
head impeller (upper stage)
The detailed performance curves are in accordance
with ISO 9906 Annex A. Vibration limits at rated

speed and rated flow are according to ISO 9905.


The motors used for the measurements are standard
DP. When using another motor brand the
performance data, like Q/H, efficiency and shaft
power must be corrected accordingly.
The characteristics given are based on:
De-aerated water at a temperature of 20oC
Density of 1.0 kg/dm3
Kinematic viscosity of 1 mm2/s (1 cst)
To prevent the pump from overheating, gathering gas,
cavitations etc., a minimum flow has to be secured.

Table 10: Performance range DPV85


50 & 60 Hz, 2 & 4 pole

20080730/20082008

ID 3264

11

2.2

2.3

Performance using other


brand of motors

The minimum frequency of the DP motor should be


limited to 10 Hz to ensure sufficient cooling. When the
rotational speed exceeds the nominal speed of the
motor, make sure that the power output of the motor
is suitable to drive the corresponding pump model.

Using other brands of motors having their own rated


speed which differ from the standard dp-motors the
exact Q/H has to be calculated, using the calculation
formular divergent speed.

The converted frequency from an average variable


frequency drive will have a rather high pulse rise time,
which creates heat in the winding. To be suitable for
this kind of application, the DP motors are built in
accordance with IEC 60034-17.

2.4

Divergent speed calculation

3238/08072008

12

Performance with variable


frequency drive

2.5

How to read the values from the curves

To find the required hydraulic information from the


published curves, it is important to know the
application in which the pump has to be installed.
There are two main distinction to be made:
A
Flow determined (like booster sets and
cleaning) Opening taps
B
Pressure determined (like boiler feed and
reverse osmosis systems) Facing counter
pressure.
3227

Pump size / no of stages.


Installed motor power
Capacity @ Pressure

NPSH (m)

Hydraulic efficiency (%)

3227/04072008

Required power (P2)

O
z
A
B

Calculated duty point


Actual hydraulic performance
Flow determined
Pressure determined

13

Technical specifications

3.1

DPV(C/S)F 85 50 Hz, with 2 pole motor 2900 rpm

3.1.1

Hydraulic performance

14

20080076A/26062008

ID3229

3.1.2

Drawing

20080040-A/14082008

ID 3095

Dimensions and weight

5.5

PN16

E2 [mm]

E1 [mm]

F2 [mm]

F1 [mm]

E2 [mm]

E1 [mm]

F2 [mm]

V(S)F
F1 [mm]

Weight [kg]

-1

Flange

No. RH

P2 [kW]

No. stages

VCF

Weight [kg]

3.1.3

116

970

641

233

162

118

970

641

233

7.5

120

998

641

233

162

122

998

641

233

162
162

-2

11

206

1282

780

315

206

208

1282

780

315

206

-1

15

220

1282

780

315

206

222

1282

780

315

206

15

220

1282

780

315

206

222

1282

780

315

206

2
3

-2

18.5

245

1435

889

315

206

247

1435

889

315

206

-1

22

281

1484

889

350

225

283

1484

889

350

225

22

281

1484

889

350

225

283

1484

889

350

225

3
4

-2

30

363

1648

998

400

290

365

1648

998

400

290

-1

30

363

1648

998

400

290

365

1648

998

400

290

30

363

1648

998

400

290

365

1648

998

400

290

4
5

-2

37

387

1757

1107

400

290

389

1757

1107

400

290

-1

37

387

1757

1107

400

290

389

1757

1107

400

290

37

387

1757

1107

400

290

389

1757

1107

400

290

505

1923

1216

466

373

506

1923

1216

466

373

5
6

-2

45

-1

45

505

1923

1216

466

373

506

1923

1216

466

373

45

505

1923

1216

466

373

506

1923

1216

466

373

6
20080151-E

PN40

15

3.2

DPV(C/S)F 85 50 Hz, with 4 pole motor 1450 rpm

3.2.1

Hydraulic performance

16

20080536-A/21082008

ID3233

3.2.2

Drawing

20080542-C/0312008

3235

Dimensions and weights


V(S)F

1460

1077

266

179

182

1460

1077

266

179

5.5

181

1460

1077

266

179

182

1460

1077

266

179

E2 [mm]

182

179

E1 [mm]

179

266

F2 [mm]

266

1077

F1 [mm]

1077

1460

E2 [mm]

1460

181

PN16

E1 [mm]

181

5.5

F2 [mm]

5.5

-1

F1 [mm]

-2

Flange

No. RH

P2 [kW]

No. stages

Weight [kg]

VCF

Weight [kg]

3.2.3

-2

5.5

191

1569

1186

266

179

192

1569

1186

266

179

-1

5.5

191

1569

1186

266

179

192

1569

1186

266

179

5.5

191

1569

1186

266

179

192

1569

1186

266

179

6
20080540-C

17

3.3

DPV(C/S)F 85 60 Hz, with 2 pole motor 3500 rpm

3.3.1

Hydraulic performance

18

20080077-A/21082008

ID3090

3.3.2

Drawing

20080040-A/14082008

ID 3095

Dimensions and weights

PN16

E2 [mm]

E1 [mm]

F2 [mm]

F1 [mm]

E2 [mm]

E1 [mm]

F2 [mm]

11

V(S)F
F1 [mm]

P2 [kW]

-1

Weight [kg]

No RH

Flange

No. stages

VCF

Weight [kg]

3.3.3

197

1173

671 315 206

198

1173

671

315

15

211

1173

671 315 206

212

1173

671

315

206
206

-2

18.5

235

1326

780 315 206

237

1326

780

315

206

-1

22

271

1375

780 350 225

273

1375

780

350

225

30

343

1430

780 400 290

345

1430

780

400

290

2
3

-2

30

353

1539

889 400 290

355

1539

889

400

290

-1

37

367

1539

889 400 290

369

1539

889

400

290

45

471

1596

889 466 373

472

1596

889

466

373

45

480

1705

998 466 373

482

1705

998

466

373

3
4

-2

20080152-E

19

3.4

DPV(C/S)F 85 60 Hz, with 4 pole motor 1750 rpm

3.4.1

Hydraulic performance

20

20080537-A/21082008

ID3234

3.4.2

Drawing

20080542-C/0312008

3235

Dimensions and weights

-2

5.5

PN16

E2 [mm]

E1 [mm]

F2 [mm]

F1 [mm]

E2 [mm]

E1 [mm]

F2 [mm]

V(S)F
F1 [mm]

Weight [kg]

-1

Flange

No. RH

P2 [kW]

No. stages

VCF

Weight [kg]

3.4.3

161

1242

859

266

179

163

1242

5.5

161

1242

859

266

179

163

1242

859 266 179


859 266 179

5.5

171

1351

968

266

179

172

1351

968 266 179

20080541-C

21

3.5

DPV(C/S)F 85 50 Hz, 2 pole without motor @ 2900 rpm (IEC)

3.5.1

Hydraulic performance

Capacity [l/s]

0.0

10.0

15.0

20.0

22.5

23.6

25.0

30.6

Capacity [m3/h]

0.00

36.00

54.00

72.00

81.00

85.00

90.00

110.00

No of stages \ mwc [m]

[m]

[m]

[m]

[m]

[m]

[m]

[m]

1-1

21.49

20.20

17.91

16.29

15.45

14.28

8.25

28.07

26.64

25.48

23.67

22.44

21.81

20.94

16.48

2-2

44.27

42.00

39.10

34.20

30.81

29.08

26.69

14.54

2-1

49.98

47.32

44.65

40.31

37.33

35.81

33.73

23.08

55.81

52.74

50.25

46.42

43.84

42.52

40.72

31.55

3-2

72.51

68.81

64.79

58.13

53.52

51.16

47.91

31.26

3-1

77.79

73.63

69.75

63.54

59.30

57.12

54.14

38.92

83.78

79.22

75.53

69.83

65.98

64.01

61.32

47.59

4-2

98.69

93.14

87.55

78.61

72.53

69.43

65.19

43.67

4-1

104.44

98.47

93.07

84.63

78.92

76.02

72.05

51.91

110.38

103.98

98.76

90.80

85.46

82.76

79.05

60.29

5-2

126.39

119.24

112.35

101.41

94.00

90.22

85.05

58.82

5-1

132.32

124.73

118.03

107.58

100.53

96.95

92.04

67.18

138.48

130.45

123.91

113.94

107.25

103.85

99.21

75.68

6-2

153.80

145.10

137.00

124.14

115.41

110.95

104.85

73.82

6-1

159.94

150.83

142.90

130.51

122.13

117.86

112.01

82.29

166.30

156.75

148.98

137.04

129.01

124.92

119.32

90.86

P st [W]

3914

4763

5459

6185

6523

6663

6827

7304

Preduced head
1/2 st [W]

2458

3257

4067

4808

5071

5153

5220

4979

1.3

1.5

1.9

2.4

2.7

3.1

5.8

NPSH [m]
20080617

22

22.49

3.5.2

Drawing

20080527-B/14082008

3236

Dimensions and weights


V(S)F

5.5

PN16

Without TBH
F2 [mm]

With TBH

Weight [kg]

F2 [mm]

Weight [kg]

Without TBH

F2 [mm]

Weight [kg]

-1

Flange

No. RH

P2 [kW]

No. stages

With TBH

F2 [mm]

VCF

Weight [kg]

3.5.3

98

775

79

641

100

775

81

7.5

98

775

79

641

100

775

81

641
641

-2

11

120

914

101

780

122

914

103

780

-1

15

120

914

101

780

122

914

103

780

15

120

914

101

780

122

914

103

780

2
3

-2

18.5

130

1023

111

889

132

1023

113

889

-1

22

130

1023

111

889

132

1023

113

889

22

130

1023

111

889

132

1023

113

889

3
4

-2

30

143

1132

124

998

145

1132

126

998

-1

30

143

1132

124

998

145

1132

126

998

30

143

1132

124

998

145

1132

126

998

4
5

-2

37

153

1241

134

1107

155

1241

136

1107

-1

37

153

1241

134

1107

155

1241

136

1107

37

153

1241

134

1107

155

1241

136

1107

172

1350

153

1216

173

1350

154

1216

5
6

-2

45

-1

45

172

1350

153

1216

173

1350

154

1216

45

172

1350

153

1216

173

1350

154

1216

PN40

20080524-B

TBH = Thrust Bearing Housing

23

3.6

DPV(C/S)F 85 50 Hz, 4 pole without motor @ 1450 rpm (IEC)

3.6.1

Hydraulic performance

Capacity [l/s]

0.0

5.0

7.5

10.0

11.3

11.8

12.5

15.13

Capacity [m3/h]

0.00

18.00

27.00

36.00 m/h

40.50

42.50

45.00

55.00

No of stages \ mwc [m]

[m]

[m]

[m]

[m]

[m]

[m]

[m]

5-2

31.60

29.81

28.09

25.35

23.50

22.55

21.26

14.71

5-1

33.08

31.18

29.51

26.89

25.13

24.24

23.01

16.79

34.62

32.61

30.98

28.48

26.81

25.96

24.80

18.92

6-2

38.45

36.28

34.25

31.04

28.85

27.74

26.21

18.46

6-1

39.99

37.71

35.72

32.63

30.53

29.46

28.00

20.57

41.57

39.19

37.25

34.26

32.25

31.23

29.83

22.72

P st [W]

489

595

682

773

815

833

853

913

P 1/2 st [W]

307

407

508

601

634

644

652

622

0.3

0.4

0.5

0.6

0.7

0.8

1.5

NPSH [m]
20080618

24

3.6.2

Drawing

20080527-B/14082008

3236

3.6.3
Dimensions and weights
On request

25

3.7

DPV(C/S)F 85 60 Hz, 2 pole without motor @ 3500 rpm (IEC)

3.7.1

Hydraulic performance at 3500 rpm

Capacity [l/s]

0.0

12.0

18.0

24.0

27.0

28.3

30.0

36.7

Capacity [m3/h]

0.00

43.20

64.80

86.40

97.20

102.00

108.00

132.00

No of stages \ mwc

[m]

[m]

[m]

[m]

[m]

[m]

[m]

[m]

1-1

32.39

30.95

29.09

25.79

23.45

22.24

20.57

11.88

40.42

38.36

36.70

34.09

32.31

31.40

30.15

23.74

2-2

63.75

60.47

56.30

49.25

44.37

41.87

38.44

20.94

2-1

71.97

68.14

64.29

58.04

53.76

51.57

48.57

33.24

80.36

75.94

72.36

66.85

63.13

61.23

58.64

45.43

3-2

104.42

99.08

93.30

83.71

77.07

73.67

68.99

45.01

3-1

112.01

106.02

100.44

91.50

85.39

82.26

77.97

56.05

120.64

114.07

108.76

100.56

95.01

92.18

88.30

68.53

4-2

142.11

134.12

126.08

113.20

104.44

99.98

93.87

62.88

P st [W]

6764

8230

9433

10687

11273

11514

11797

12621

P 1/2 st [W]

4248

5627

7028

8308

8763

8905

9020

8603

1.9

2.2

2.8

3.4

3.8

4.4

8.3

NPSH [m]
20080619

26

3.7.2

Drawing

20080527-B/14082008

3236

Dimensions and weights


V(S)F

15

PN16

Without TBH
F2 [mm]

With TBH

Weight [kg]

F2 [mm]

Weight [kg]

11

Without TBH
F2 [mm]

P2 [kW]

-1

Weight [kg]

No. RH

Flange

No. stages

With TBH

F2 [mm]

VCF

Weight [kg]

3.7.3

111

805

92

671

112

805

93

671

111

805

92

671

112

805

93

671

-2

18.5

120

914

101

780

122

914

103

780

-1

22

120

914

101

780

122

914

103

780

30

123

914

104

780

125

914

106

780

-2

30

133

1023

114

889

135

1023

116

889

-1

37

133

1023

114

889

135

1023

116

889

45

138

1023

119

889

139

1023

120

889

45

147

1132

128

998

149

1132

130

998

3
4

-2

20080525-C

27

3.8

DPV(C/S)F 85 60 Hz, 4 pole without motor @ 1750 rpm (IEC)

3.8.1

Hydraulic performance

Capacity [l/s]

0.0

6.0

9.0

12.0

13.5

14.2

15.0

18.3

Capacity [m3/h]

0.00

21.60

32.40

43.20

48.60

51.00

54.00

66.00

3-1

28.00

26.51

25.11

22.88

21.35

20.56

19.49

14.01

30.16

28.52

27.19

25.14

23.75

23.04

22.08

17.13

4-2

35.53

33.53

31.52

28.30

26.11

24.99

23.47

15.72

P st [W]

846

1029

1179

1336

1409

1439

1475

1578

P 1/2 st [W]

531

703

879

1038

1095

1113

1128

1075

0.5

0.5

0.7

0.9

1.0

1.1

2.1

No of stages \ mwc

NPSH [m]
20080620

28

3.8.2

Drawing

20080527-B/14082008

3236

3.8.3
Dimensions and weights
On request

29

3.9

Sealing

The DPVF 85 can be fitted with an Easy Access seal


or a cartridge seal.
At selection of the seal, the following parameters
must be taken into account:
Pumped medium
Medium temperature
Maximum pressure
Expected life span
Table 11: Seal options

In the following diagram the right seal type can be


chosen, depending on the temperature and pressure
class.
The temperature is given as an absulute value and as
T: The deviation from 20 C room temperature

30

20081204-A/12012009

ID 3237

Table 12: Seal code


Code acc. to EN 12756 Code Material
B Q1 E GG

11

Note

Carbon / Silicon carbide / EPDM

Ca SiC EPDM

Low pressure

B Q1 V GG

12

Carbon / Silicon carbide / Viton

Ca SiC Viton

Low pressure

Q1 B E GG

13

Silicon carbide / Carbon / EPDM WRc

SiC Ca EPDM

WRc approved

Q1 B V GG

14

Silicon carbide / Carbon / Viton

SiC Ca Viton

U3 U3 X4 GG

15

Tungsten carbide / Tungsten carbide / HNBR

TuC TuC HNBR


TuC TuC Viton

U3 U3 V GG

16

Tungsten carbide / Tungsten carbide / Viton

U3 B E GG

18

Tungsten carbide / Carbon / EPDM

Tuc Ca EPDM

Q1 B E GG

23

Silicon carbide / Carbon / EPDM

SiC Ca EPDM

Q1 A E GG

20

Silicon carbide / Carbon / EPDM

SiC Ca EPDM

Balanced Seal: H7N

Q1 A V GG

21

Silicon carbide / Carbon / Viton

SiC Ca Viton

Balanced Seal: H7N

Q1 A X4 GG

22

Silicon carbide / Carbon / HNBR

SiC Ca HNBR

Balanced Seal: H7N

Table 13: Material code shaft seal


Code acc. to EN 12756 Description

Material

Note

B
Q1
U3

Spring loaded ring

Carbon graphite
Silicon carbide
Tungsten carbide

Ca
SiC
TuC

Resin impregnated
Sintered pressureless
CrNiMo-binder

B
Q1
U3

Seat ring

Carbon graphite
Silicon carbide
Tungsten carbide

Ca
SiC
TuC

Resin impregnated
Sintered pressureless
CrNiMo-binder

E
V
X4

Elastomers

EPDM
Viton
HNBR

EPDM
Viton
HNBR

Ethylene propylene rubber


Fluorcarbon rubber
Hydrogenated nitrile rubber

Spring

CrNiMo steel

Other metal parts

CrNiMo steel

31

3.9.1

Easy Access seal

20070951/31102007

ID3029

32

Seal type

Material code

Seal faces

MG12-G60

B Q1 E GG

Ca

Sic

Elastomers

Seal cover

VC

EPDM

JL1040

MG12-G60

B Q1 E GG

Ca

Sic

EPDM

AISI 304

MG12-G60

B Q1 E GG

Ca

SiC

EPDM

AISI 316

RMG12-G606

Q1 B E GG

SiC

Ca

EPDM

JL1040

RMG12-G606

Q1 B E GG

SiC

Ca

EPDM

AISI 304

RMG12-G606

Q1 B E GG

SiC

Ca

EPDM

AISI 316

RMG12-G606

Q1 B E GG

SiC

Ca

EPDM WRc/ACS AISI 304

VS

z
{
z
z
{
{

RMG12-G606

U3 B E GG

TuC

Ca

EPDM E425

AISI 316

MG12-G60

B Q1 V GG

Ca

SiC

Viton

AISI 316

RMG12-G606

Q1 B V GG

SiC

Ca

Viton

AISI 316

RMG12-G606

U3 U3 V GG

TuC

TuC

Viton

AISI 316

RMG12-G606

U3 U3 X4 GG

TuC

TuC

HNBR

AISI 316

RMG12-G606

Q1 B E GG

SiC

Ca

EPDM WRc/ACS AISI 316

3.9.2

Cartridge seal

20070951/31102007

ID3028

Seal type

Material code

Seal faces

Elastomers

Seal cover

VC

MG12-G60

B Q1 E GG

Ca

SiC

EPDM

AISI 304

MG12-G60

B Q1 E GG

Ca

SiC

EPDM

AISI 316

MG12-G60

Q1 B V GG

SiC

Ca

EPDM

AISI 304

AISI 316

VS
{

RMG12-G606

Q1 B E GG

SiC

Ca

EPDM

RMG12-G606

Q1 B E GG

SiC

Ca

EPDM WRc/ACS AISI 304

RMG12-G606

U3 B E GG

TuC

Ca

EPDM E425

AISI 316

RMG12-G606

B Q1 V GG

Ca

SiC

Viton

AISI 316

RMG12-G606

Q1 Q1 V GG

SiC

Ca

Viton

AISI 316

RMG12-G606

U3 U3 V GG

TuC

TuC

Viton

AISI 316

RMG12-G606

U3 U3 X4 GG

TuC

TuC

HNBR

AISI 316

H7N (balanced)

Q1 A E GG

SiC

Ca

EPDM E425

AISI 316

H7N (balanced)

Q1 A V GG

SiC

Ca

Viton

AISI 316

H7N (balanced)

Q1 A X4 GG

SiC

Ca

HNBR

AISI 316

z Standard
{ Option

33

Connection

ID3049

ID3050

V(S)

VC

3.10.1

Module connection / base

Material Base
plate

Connection
Type

Material
flanges

Standard

Connection
size

Pressure
class1

VC

JL1040

Rigid flange

JS1030

DIN
ASME

NW100
NPS4"

PN16
Class 150

JL1040

Rigid flange

JS1030

DIN
ASME
JIS

NW100
NPS4"

PN25/40
Class 300
16/20K

JL1040

Collar flange

JS1030

DIN
ASME

NW100
NPS4"

JL1040

Collar flange

JS1030

DIN
ASME
JIS

JL1040

Collar flange

1.4308

1.4308

Collar flange

JL1040

1.4308

1.

VS

PN16
Class 150

NW100
NPS4"

PN25/40
Class 300
16/20K

DIN
ASME

NW100
NPS4"

PN16
Class 150

1.4308

DIN
ASME

NW100
NPS4"

PN16
Class 150

Collar flange

1.4308

DIN
ASME
JIS

NW100
NPS4"

PN25/40
Class 300
16/20K

Collar flange

1.4308

DIN
ASME
JIS

NW100
NPS4"

PN25/40
Class 300
16/20K

Flanges are matching with the mentioned standards.

z Standard
{ Option

34

20070947/31102007

3.10

3.11

Motor options

Options are available on rated power or one step


higher power
1

Voltage

Brand

without IEC motor

without IEC motor

2 pole motor

230/400V

DM

EFF 2

IP55 PTC

2 pole motor

400/690V

DM

EFF 2

IP55 PTC

2 pole motor

400/690V

DM

EFF 2

IP55 PTC

2 pole motor

200/346V

DM

EFF 2

IP55 PTC

2 pole motor

500/865V

DM

EFF 2

IP55 PTC

4 pole motor

400/690V

DM

EFF 2

IP55 PTC

2 pole motor

230/400V

DM

EFF 1

IP55 PTC

2 pole motor

400/690V

DM

EFF 1

IP55 PTC

2 pole motor

400/690V

DM

EFF 1

IP55 PTC

HA

2 pole motor

400/690V

DM

EFF 1

IP56 PTC

ACH {

2 pole motor

400/690V

VEM/Dutchi

EFF 2

IP55 PTC TBH

2 pole motor

400/690V

VEM/Dutchi

EFF 1

IP55 PTC TBH

2 pole motor

400/690V

Siemens

EFF 2

IP55 PTC TBH

2 pole motor

400/690V

Siemens

EFF 1

IP55 PTC TBH

2 pole motor

400/690V

Siemens

EFF 1

IP55 PTC TBH HA

2 pole motor

400/690V

VEM/Dutchi ATEX Eex d IIc T4

EFF 2

IP55 PTC TBH RC

2 pole motor

400/690V

Siemens ATEX Eex e II T3

EFF 2

IP55 PTC TBH RC

1.
2.

Eff. class

Description

V(C/S)
{

TBH

{
{
z
RC

{
{

TBH: thrust bearing housing to releave the axial load on the motor
HA: industrial connection (Harting stecker) (up to 7.5 kW)
RC: raincover
AHC: anti condensation heater

z Standard
{ Option

35

Article numbers

4.1

DPVCF 85 50 Hz 2900 rpm

Vertical centrifugal pump, suction and discharge connections in-line.


Incl. IEC electromotor EFF2, three phase 400/690V, 50Hz, IP55, ~2900rpm with PTC Terminal box position "3h.
Pump casing and motor stool in cast iron (JL1040). Complete hydraulic in stainless steel (AISI304).
Measuring, draining and air relieve plugs in stainless steel (AISI304).
Pipe connections in cast iron, round flange NW100.
Sealing in EPDM. Mechanical seal in "Easy Access" version in Carbon/ Silicon Carbide.
Model

36

P2

Pressure class
Hydraulics

Connection

Mechanical seal

Temperature range

Item no
2930851011B

DP

VC

F 85 /1-1 5.5kW

PN40+80C

PN16

PN10

-20/+100C

DP

VC

F 85 /1

PN40+80C

PN16

PN10

-20/+100C

2930851010B

DP

VC

F 85 /2-2 11kW

PN40+80C

PN16

PN10

-20/+100C

2930851022B

DP

VC

F 85 /2-1 15kW

PN40+80C

PN16

PN10

-20/+100C

2930851021B

DP

VC

F 85 /2

PN40+80C

PN16

PN10

-20/+100C

2930851020B

DP

VC

F 85 /3-2 18.5kW

PN40+80C

PN16

PN10

-20/+100C

2930851032B

DP

VC

F 85 /3-1 22kW

PN40+80C

PN16

PN10

-20/+100C

2930851031B

DP

VC

F 85 /3

22kW

PN40+80C

PN16

PN10

-20/+100C

2930851030B

DP

VC

F 85 /4-2 30kW

PN40+80C

PN16

PN25

-20/+100C

2930851042B

DP

VC

F 85 /4-1 30kW

PN40+80C

PN16

PN25

-20/+100C

2930851041B

DP

VC

F 85 /4

30kW

PN40+80C

PN16

PN25

-20/+100C

2930851040B

DP

VC

F 85 /5-2 37kW

PN40+80C

PN16

PN25

-20/+100C

2930851052B

DP

VC

F 85 /5-1 37kW

PN40+80C

PN16

PN25

-20/+100C

2930851051B

DP

VC

F 85 /5

37kW

PN40+80C

PN16

PN25

-20/+100C

2930851050B

DP

VC

F 85 /6-2 45kW

PN40+80C

PN25/40

PN25

-20/+100C

2930851062B

DP

VC

F 85 /6-1 45kW

PN40+80C

PN25/40

PN25

-20/+100C

2930851061B

DP

VC

F 85 /6

PN40+80C

PN25/40

PN25

-20/+100C

2930851060B

7.5kW

15kW

45kW

4.2

DPVF 85 50 Hz 2900 rpm

Vertical centrifugal pump, suction and discharge connections in-line.


Incl. IEC electromotor EFF2, three phase 400/690V, 50Hz, IP55, ~2900rpm with PTC Terminal box position "3h.
All wetted parts (Pump casing and complete hydraulic) in stainless steel (AISI304).
Measuring, draining and air relieve plugs in stainless steel (AISI304).
Pipe connections in cast iron, round flange NW100.
Sealing in EPDM. Mechanical seal in "Easy Access" version in Carbon / Silicon Carbide.
Model

P2

Pressure class
Hydraulics

Connection

Temperature range

Item no

Mechanical seal

DP

V F 85 /1-1 5.5kW

PN40+80C

PN16

PN10

-20/+100C

2920851011B

DP

V F 85 /1

PN40+80C

PN16

PN10

-20/+100C

2920851010B

DP

V F 85 /2-2 11kW

PN40+80C

PN16

PN10

-20/+100C

2920851022B

DP

V F 85 /2-1 15kW

PN40+80C

PN16

PN10

-20/+100C

2920851021B

DP

V F 85 /2

PN40+80C

PN16

PN10

-20/+100C

2920851020B

DP

V F 85 /3-2 18.5kW

PN40+80C

PN16

PN10

-20/+100C

2920851032B

DP

V F 85 /3-1 22kW

PN40+80C

PN16

PN10

-20/+100C

2920851031B

DP

V F 85 /3

22kW

PN40+80C

PN16

PN10

-20/+100C

2920851030B

DP

V F 85 /4-2 30kW

PN40+80C

PN16

PN25

-20/+100C

2920851042B

DP

V F 85 /4-1 30kW

PN40+80C

PN16

PN25

-20/+100C

2920851041B

DP

V F 85 /4

30kW

PN40+80C

PN16

PN25

-20/+100C

2920851040B

DP

V F 85 /5-2 37kW

PN40+80C

PN16

PN25

-20/+100C

2920851052B

DP

V F 85 /5-1 37kW

PN40+80C

PN16

PN25

-20/+100C

2920851051B

DP

V F 85 /5

37kW

PN40+80C

PN16

PN25

-20/+100C

2920851050B

DP

V F 85 /6-2 45kW

PN40+80C

PN25/40

PN25

-20/+100C

2920851062B

DP

V F 85 /6-1 45kW

PN40+80C

PN25/40

PN25

-20/+100C

2920851061B

DP

V F 85 /6

PN40+80C

PN25/40

PN25

-20/+100C

2920851060B

7.5kW

15kW

45kW

37

4.3

DPVSF 85 50 Hz 2900 rpm

Vertical centrifugal pump, suction and discharge connections in-line.


Incl. IEC electromotor EFF2, three phase 400/690V, 50Hz, IP55, ~2900rpm with PTC Terminal box position "3h.
All wetted parts (Pump casing and complete hydraulic) in stainless steel (AISI316).
Measuring, draining and air relieve plugs in stainless steel (AISI316).
Pipe connections in cast iron, round flange NW100.
Sealing in Viton. Mechanical seal in "Easy Access" version in Carbon / Silicon Carbide.
Model

P2

Pressure class
Hydraulics

38

Connection

Temperature range

Item no

Mechanical seal

DP

VS F 85 /1-1 5.5kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940851011B

DP

VS F 85 /1

PN40+80C

PN16

PN10

-20/+80(+120)C

2940851010B

DP

VS F 85 /2-2 11kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940851022B

DP

VS F 85 /2-1 15kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940851021B

DP

VS F 85 /2

PN40+80C

PN16

PN10

-20/+80(+120)C

2940851020B

DP

VS F 85 /3-2 18.5kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940851032B

DP

VS F 85 /3-1 22kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940851031B

DP

VS F 85 /3

22kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940851030B

DP

VS F 85 /4-2 30kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940851042B

DP

VS F 85 /4-1 30kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940851041B

DP

VS F 85 /4

30kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940851040B

DP

VS F 85 /5-2 37kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940851052B

DP

VS F 85 /5-1 37kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940851051B

DP

VS F 85 /5

37kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940851050B

DP

VS F 85 /6-2 45kW

PN40+80C

PN25/40

PN25

-20/+80(+120)C

2940851062B

DP

VS F 85 /6-1 45kW

PN40+80C

PN25/40

PN25

-20/+80(+120)C

2940851061B

DP

VS F 85 /6

PN40+80C

PN25/40

PN25

-20/+80(+120)C

2940851060B

7.5kW

15kW

45kW

4.4

DPVCF 85 60 Hz 3500 rpm

Vertical centrifugal pump, suction and discharge connections in-line.


Incl. IEC electromotor EFF2, three phase 230/400V, 60Hz, IP55, ~3500rpm with PTC Terminal box position "3h.
Pump casing and motor stool in cast iron (JL1040). Complete hydraulic in stainless steel (AISI304).
Measuring, draining and air relieve plugs in stainless steel (AISI304).
Pipe connections in cast iron, round flange NW100.
Sealing in EPDM. Mechanical seal in "Easy Access" version in Carbon / Silicon Carbide.
Model

P2

Pressure class
Hydraulics

Connection

Temperature range Item no


Mechanical
seal

DP

VC

F 85

/1-1

11kW

PN40+80C

PN16

PN10

-20/+100C

2930856011A

DP

VC

F 85

/1

15kW

PN40+80C

PN16

PN10

-20/+100C

2930856010A

DP

VC

F 85

/2-2

18.5kW

PN40+80C

PN16

PN10

-20/+100C

2930856022A

DP

VC

F 85

/2-1

22kW

PN40+80C

PN16

PN10

-20/+100C

2930856021A

DP

VC

F 85

/2

30kW

PN40+80C

PN16

PN10

-20/+100C

2930856020A

DP

VC

F 85

/3-2

30kW

PN40+80C

PN16

PN25

-20/+100C

2930856032A

DP

VC

F 85

/3-1

37kW

PN40+80C

PN16

PN25

-20/+100C

2930856031A

DP

VC

F 85

/3

45kW

PN40+80C

PN16

PN25

-20/+100C

2930856030A

DP

VC

F 85

/4-2

45kW

PN40+80C

PN16

PN25

-20/+100C

2930856042A

39

4.5

DPVF 85 60 Hz 3500 rpm

Vertical centrifugal pump, suction and discharge connections in-line.


Incl. IEC electromotor EFF2, three phase 230/400V, 60Hz, IP55, ~3500rpm with PTC Terminal box position "3h.
All wetted parts (Pump casing and complete hydraulic) in stainless steel (AISI304).
Measuring, draining and air relieve plugs in stainless steel (AISI304).
Pipe connections in cast iron, round flange NW100.
Sealing in EPDM. Mechanical seal in "Easy Access" version in Carbon / Silicon Carbide.
Model

P2

Pressure class
Hydraulics

40

Connection

Temperature range

Item no

Mechanical seal

DP

V F 85 /1-1 11kW

PN40+80C

PN16

PN10

-20/+100C

2920856011A

DP

V F 85 /1

PN40+80C

PN16

PN10

-20/+100C

2920856010A

DP

V F 85 /2-2 18.5kW

PN40+80C

PN16

PN10

-20/+100C

2920856022A

DP

V F 85 /2-1 22kW

PN40+80C

PN16

PN10

-20/+100C

2920856021A

DP

V F 85 /2

30kW

PN40+80C

PN16

PN10

-20/+100C

2920856020A

DP

V F 85 /3-2 30kW

PN40+80C

PN16

PN25

-20/+100C

2920856032A

DP

V F 85 /3-1 37kW

PN40+80C

PN16

PN25

-20/+100C

2920856031A

DP

V F 85 /3

45kW

PN40+80C

PN16

PN25

-20/+100C

2920856030A

DP

V F 85 /4-2 45kW

PN40+80C

PN16

PN25

-20/+100C

2920856042A

15kW

4.6

DPVSF 85 60 Hz 3500 rpm

Vertical centrifugal pump, suction and discharge connections in-line.


Incl. IEC electromotor EFF2, three phase 230/400V, 60Hz, IP55, ~3500rpm with PTC Terminal box position "3h.
All wetted parts (Pump casing and complete hydraulic) in stainless steel (AISI316).
Measuring, draining and air relieve plugs in stainless steel (AISI316).
Pipe connections in cast iron, round flange NW100.
Sealing in Viton. Mechanical seal in "Easy Access" version in Carbon / Silicon Carbide.
Model

P2

Pressure class
Hydraulics

Connection

Mechanical seal

Temperature range

Item no

DP

VS F 85 /1-1 11kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940856011A

DP

VS F 85 /1

PN40+80C

PN16

PN10

-20/+80(+120)C

2940856010A

DP

VS F 85 /2-2 18.5kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940856022A

DP

VS F 85 /2-1 22kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940856021A

DP

VS F 85 /2

30kW

PN40+80C

PN16

PN10

-20/+80(+120)C

2940856020A

DP

VS F 85 /3-2 30kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940856032A

DP

VS F 85 /3-1 37kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940856031A

DP

VS F 85 /3

45kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940856030A

DP

VS F 85 /4-2 45kW

PN40+80C

PN16

PN25

-20/+80(+120)C

2940856042A

15kW

41

Chemical resistance

5.1

Chemical resistance

Table 14: Chemical resistance


Media text

42

Concentration

T-max
[C]

Mechanical seal and elastomer variant


BQ1EGG

BQ1VGG

U3U3X4GG U3U3VGG U3BEGG

Ca / SiC

Ca / SiC

Tuc / TuC

TuC / TuC

TuC / Ca

Q1BEGG

Q1BVGG

SiC / Ca

SiC / Ca

EPDM

Viton

HNBR

Viton

EPDM

Alkaline (bottle rinsing; sodium


hydroxide; pH<=9.5)

2%

40

V,VS

Alcohol (ethanol)

100%

60

Alum (potassium aluminium sulphate)

3%

80

Aluminium sulphate

5%

60

Ammonium sulphate

20%

60

V,VS

Antifreeze (glycol base, salt-free)

20% - 50% 60

V,VS

V,VS

V,VS

Antifreeze (glycol base, salt-free)

20% - 50% 80

V,VS

V,VS

V,VS

Antifreeze (glycol base, salt-free)

20% - 50% 100

V,VS

Antifreeze (glycol base, salt-free)

20% - 50% 110

V,VS

V,VS

Bicarbonate of ammonium

10%

40

V,VS

Boiler feed water (Acc. Vd TV


1466)

100%

120

VCF, V, VS

V,VS
VS
V,VS

VCF, V, VS

Buttermilk

100%

60

V,VS

Butyl alcohol (butanol)

100%

60

V,VS

V,VS

Calcium acetate

10%

60

V,VS

Calcium nitrate (non-acidic)

10%

60

Cider (Apple wine)

100%

40

Citric acid

25%

30

Citric acid

10%

30

Condensate (Acc. Vd TV 1466)

100%

100

Cooling water

100%

80

Copper sulphate

5%

80

Corn oil

100%

100

Decarbonised water (softened)

100%

120

Deionised water (demineralised)

100%

60

V,VS

Deionised water (demineralised)

100%

100

V,VS

Diesel oil (extra light) resp. (light)

100%

80

Diethylene glycol (salt-free)

100%

60

V,VS

V,VS

Diethylene glycol (salt-free)

100%

100

V,VS

V,VS

Ethylene glycol (salt-free)

100%

60

V,VS

V,VS

Ethylene glycol (salt-free)

100%

100

V,VS

V,VS

Ferric-II-sulphate

5%

80

Fire-fighting water

100%

60

Fruit juice (pH = 6.5)

100%

60

V,VS

Fuel oil (light)

100%

80

V,VS

V,VS
V,VS

V,VS
V,VS
V,VS

VS

VS
V,VS
V,VS
V,VS
V,VS

V,VS

V,VS
V,VS

Media text

Concentration

T-max
[C]

Mechanical seal and elastomer variant


BQ1EGG

BQ1VGG

U3U3X4GG U3U3VGG U3BEGG

Ca / SiC

Ca / SiC

Tuc / TuC

TuC / TuC

TuC / Ca

Q1BEGG

Q1BVGG

SiC / Ca

SiC / Ca

EPDM

Viton

HNBR

Viton

EPDM

Glycerin

40%

60

V,VS

V,VS

Glycerin

40%

80

V,VS

V,VS

Heating water (Acc VDI 2035)

100%

60

VCF, V, VS

Heating water (Acc VDI 2035)

100%

100

VCF, V, VS

Heating water (Acc Vd TV 1466) 100%

120

Isopropyl alcohol (2-propanol)

100%

60

V,VS

Isopropyl alcohol (2-propanol)

100%

80

V,VS

Kerosene

100%

80

V,VS

Lactic acid

5%

60

V,VS

Lactic acid

40%

60

V,VS

Linseed oil

100%

60

V,VS

Linseed oil + 3% sulphur acid

100%

60

V,VS

Magnesium sulphate

10%

80

V,VS

Maleic acid

10%

60

VS

Oil (max 5%) / water mixture

100%

80

V,VS

Partly desalinated water

100%

120

Peanut oil

100%

90

VCF, V, VS
VCF, V, VS
VCF, V, VS

V,VS
V,VS

Petroleum

100%

80

V,VS

Phosphoric acid

5%

20

V,VS

Potassium hydroxide

5%

40

Potassium nitrate

5%

30

Potassium sulphate

3%

20

Pure water (chemically neutral)

100%

60

Rapeseed oil

100%

100

Rinsing water

100%

70

V,VS

Sea water (continuous operation)

100%

25

VS

V,VS
V,VS
VS
V,VS
V,VS

Sodium carbonate

6%

60

Sodium hydroxide (soda lye)

5%

40

Sodium nitrate (non-acidic)

10%

60

V,VS
V,VS

Sodium sulphate (non-acidic)

5%

60

Soybean oil

100%

100

Spirits (40% Ethanol)

40%

60

Sulphuric acid

5%

20

Swimming pool water (no brine)

100%

60

Tannic acid

20%

80

Tap water (Drinking water)

100%

60

Tartaric acid

8%

40

Trisodium phosphate

4%

80

V,VS
V,VS

V,VS
V,VS
VS
VS
V,VS
VCF, V, VS
V,VS
V,VS

Untreated water (solids < 20 ppm) 100%

60

Vinegar (wine vinegar)

60

VS

40

Wine (white,red)

10%

V,VS

43

dp pumps
dp pumps
P.O. Box 28
2400 AA Alphen aan den Rijn
The Netherlands
t +31 172 48 83 25
f +31 172 46 89 30
dp@dp-pumps.com
www.dp-pumps.com
07/2009
97004442
Subject to modifications. Digital alteration, publication or distribution of the content of this document without prior notice is strictly prohibited.
Permission for use, copying and distribution of this document as published by DP-Pumps is granted on the condition that no part of the
document is used for information or commercial purposes outside of the DP-Pumps organisation or one of its recognised dealerships.

Вам также может понравиться