Вы находитесь на странице: 1из 2

12.

AquaSeal SYSTEMS

condenser-exhauster systems Model DVW2000DF1-50

: Optimize your turbine efficiency with the Dekker condenser-exhauster system.


Efficient two-stage design provides excellent performance and condensing capabilities at high vacuum. Heavy duty pump design requires a minimum of maintenance. Features stainless steel impellers and shaft as standard. Features mechanical shaft seals as standard (minimizes air-leakage and shaft damage). Complete package design includes all necessary components for automatic operation.
INLET VSW

LEGEND: temporary inlet strainer


CONTROL PANEL

Stainless steel plate type heat exchanger offers superior heat transfer and is expandable for customized conditions, shell and tube available upon request. Superior evacuation (hogging) characteristics versus steam ejectors. Electrical control panel, including skid wiring available as an option.

Y-strainer pneumatic valve solenoid valve

DPSW

DISCHARGE

globe valve ball valve

check valve butterfly valve

M
LRVP C

SEPARATOR TANK
V

flow meter vane type flow meter rotameter vacuum gauge temperature gauge pressure gauge compound gauge low level switch motor

OVERFLOW T DRAIN

LLS

WATER MAKE-UP

P
M
LLS

Heavy duty TEFC motors with service factor are standard.


55.64 25.02
6 FLANGE SYSTEM DISCHARGE

DRAIN

recirculation pump

DVW2000DF1-50
14.61

Performance Characteristics Holding capacity*: 25 SCFM at 1 HgA Pump speed: 720 RPM Motor: 125 HP Weight: consult factory Maximum noise level (at 3 feet): 85dBA * Note: Based on 55oF cooling water to heat exchanger. For higher cooling water temperature see performance curve page.
935 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 46360-5672 TOLL-FREE: 888-925-5444 TEL.: 219-861-0661 FAX: 219-861-0662

92.81
6 FLANGE SYSTEM INLET

13.13

58.89

136.00

80.00

Information contained in this document is for reference only. Subject to change without notice.
Please visit our Website at www.dekkervacuum.com Page number 12-570 Reference 0105/3

12. AquaSeal SYSTEMS

condenser-exhauster systems Model DVW2000DF1-50

DVW2000DF1-50
Condenser-exhauster performance curve
200 180 160

coolingwater temperature o o 50 F 60 F 70 F 80oF o 90 F


o

Suction Air Capacity SCFM

140 120 100 80 60 40 20 0 1 2 3 Final pressure HgA 4 5 6

Condenser-exhauster evacuation curve of 10,000 cubic feet (assume 60oF water and no leakage)
18 16 14

Time Minutes

12 10 8 6 4 2 0 0 5 10 15 Final pressure HgA 20 25 30 Tolerance 10 %


Please visit our Website at www.dekkervacuum.com Page number 12-571 Reference 0105/3

Barometric Pressure 29.92Hg


935 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 46360-5672 TOLL-FREE: 888-925-5444 TEL.: 219-861-0661 FAX: 219-861-0662