Вы находитесь на странице: 1из 6

Type: P125/I2/SVB Article No.

: 207293

Ordering information Design Description Main conducting paths No. of poles Auxiliary contacts Auxiliary contacts Max. threephase motor rating (per set of 3 contacts) 5060 Hz AC3 400/415 V 5060 Hz Rated uninterrupted current P Iu M N/O B kW A Surface mounting Without auxiliary contacts 3 0 0 13 25 According to IEC/EN 602041, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position

Note for table header

Contact sequence

General Standards Lifespan, mechanical


1

IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA,UL Switchdisconnectors to IEC/EN 609473 Operations 106 0,3

Maximum operating frequency Climatic proofing Ambient temperature Open Enclosed Mounting position Documentation Mechanical shock resistance (shock duration 20 ms) Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current open Enclosed Loadcarrying capacity in intermittent operation, Class 12 AB 25 % DF AB 40 % DF AB 60 % DF Shortcircuit rating Fuse Rated shorttime withstand current (1 s current) Switching angles Current heat loss per contact at Ie Terminal capacities Solid or stranded Flexible with ferrule to DIN 46228 Terminal screw Tightening torque Switching capacity AC Rated making capacity cos = 0.35

Operations/h

50 Damp heat, constant, to IEC 60068278; Damp heat, cyclical, to IEC 60068230 C C 25/50 25/40 As required Main catalogue HPL g > 15

Ue Uimp

V AC V AC

690 6000 III/3

Iu Iu

A A

25 25

Ie Ie Ie

2 1,6 1,3

A gG/gL 25 Icw Arms W 640 90 1,1 1 (1.5 6) 2 (1.5 6) 1 (1 4) 2 (1 4) M4 Nm 1.6

mm2 mm2

240

Rated breaking capacity, motor load switch cos = 0.35 230 V 400 V 500 V 690 V Rated operational current 440 V loadbreak switch AC21A AC3 motor load switch motor rating 230 V 400 V 500 V 690 V AC23A Motor load switches (main switches maintenance switches) 230 V 400 V 500 V 690 V DC DC1, Loadbreak switches L/R = 1 ms Rated operational current Voltage per contact pair in series DC23A, Motor load switches L/R = 15 ms 24 V Rated operational current Contacts 48 V Rated operational current Contacts 60 V Rated operational current Contacts 120 V Rated operational current Contacts
3

A A A A Ie A

190 150 170 150 25

P P P P

kW kW kW kW

5,5 7,5 7,5 7,5

P P P P

kW kW kW kW

7 13 11 11

Ie

A V

25 60

Ie

25

Quantity 1 Ie A 25

Quantity 2 Ie A 25

Quantity 3 Ie A 12

Quantity 3

Notes Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current Iu is stated at max. connected crosssection. For terminal capacity solid, stranded and flexible: Max. 2 crosssection sizes difference admissible when using 2 conductors. Dimensions 3 Padlocks For utilisation category AC4 (extreme load: 100 % inching, reversing or plugging) The blocked rotor current of the motor should not exceed the rated current of the switch for AC21A to ensure a reasonable device lifespan.

Explaination

Dimensions

Dimensions

Characteristic curve

Moeller GmbH, HeinMoellerStr. 711, D53115 Bonn EMail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. Subject to modifications. HPLC2006GBINT V2.3