Академический Документы
Профессиональный Документы
Культура Документы
STANDARD
IEC 60840 ,Cl 9.2 and tabel 4 IEC 60840,CL9.3 IEC 60840,CL10,5 IEC 60840,CL10,5 IEC 60840,Cl 9.4; IEC 60229,Cl3.1 IEC 60940,Cl.10.6.2 ,tav =avv value IEC 60840,Cl.10.7.1. IEC 60840,Cl. 10.6.3. tav = av value IEC 60840,Cl. 10.6.3.
Voltage test
3 Measurement of electrical resistance conductor 4 Measurement of capacitance 5 Electric test on non-metalic inner sheath 6 Measurement of tickness of insulation
NO
1
PENGUJIAN
Hot test set
STANDART
IEC 60840 ,Cl 10.9 and tabel 7 IEC 60811-2-1,Cl.9
2 3 4 5 6
Bending test
Partial discharge Heating cycle test Partial discharge Voltage test
IEC 60840,CL12.3.3 IEC 60840,CL12.3.4 and table 4,IEC 608853 IEC 60840,CL12.3.6. IEC 60840,CL12.3.4 and table 4,IEC 608853 IEC 60940,Cl.9.3. and table 4
NO
1
PENGUJIAN
Partial discharge test on stress cone adapter and main joint sleeve
STANDART
IEC 60840 ,Cl9.2.and table 4
NO
1
PENGUJIAN
Check of dimension
STANDART
According to quality system procedur QV 750 - 2QM,Identification No;SEV 170:30603101,SM 245-S: 30805801 According to working instruction: AA5300601 TKG,AA 53160-01 TKG,AA 53180-01 TKG
Check of packing
SYARAT PENGUJIAN
Test voltage1,5Uo =131 kV sensitivit level 10 pC Test Voltage2,5 Uo =218 kV/30 menit DC value measured at 20 C max 0,021 /km C0,190F/km ( 8%acc IEC) Test voltage 25 kV DC duration 1 menit tavtn19,0 mm, tmin0,9 tn17,1 mn,(tmaxtmin)/tmin 0,15 tav0,95 tn-0,1 ; tmin3,22 mm ; tn= 3,5,mm tavto4,0 mm: tmin0,85 tn -0,1 ; tmin 3,3mm tmin 0,85 tn-0,1 : tmin3,30 mm: tn= 4,0 mm
SYARAT PENGUJIAN
Max elongation under load :175%. Max permanent elong after cooling :15% 4 samples per lot Diam.silinder 25(d+D)+5% 3,75 m,d =35 mm,D=108 mm Test voltage 1,5 Uo=131 kV ,sensitivity level 5 pC 1 heating cycle Test voltage 1,5 Uo=131 kV ,sensitivity level 5 pC Test voltage 3 Uo =261 kV/24 jam
SYARAT PENGUJIAN
Test voltage1,5Uo =131 kV ,sensitivity level 10 pc test voltage 2,5 Uo 218 kV /30 min
SYARAT PENGUJIAN
Compliance with manufacturing drawings and parts lists Compliance with packing list