MEDIUM-PRESSURE INDUSTRIAL AXIAL EXTRACTOR FANS SUITABLE FOR DUCTED

MP RANGE RED HUB

Suitable for business or


industrial buildings such as
halls, factories,
warehouses, gyms, etc.
Asynchronous induction motor
with IP55 protection and ballbearing-mounted rotor and double
grease seals.
Wing-profiled fan, superimposed
for reducing air-turbulence noise,
with high-strength, high-stability,
polypropylene blades and diecast aluminium hub.
Steel sheet-metal, polyesterpowder paint-protected frame with
streamlined intake nozzle of the

I
I
I

correct diameter, to permit easy


air passage, and elongated to
permit easy attachment to the
outlet ducts.
Circular metal protection grille,
with black epoxy-polyester paint
finish, which can be easily
removed for cleaning and
maintenance.
Speed regulated by optional
speed controller (not MP 604 T).
Ambient temperature limits:
25 min. +70C max.
Compliance to standards: please
see page 140.

Wiring diagrams shown on page XXXIII.

These units are only suitable for extracting dust-free, acid-free and noncorrosive air. They can extract into a ventilation duct or through filters.
They can also be installed on lengths of duct.

THREE PHASE

Lp
dB(A)
(3 m)

kg

Insulation

IP

max
C

402

70

6.1

cl. I

55

70

13

127

53

6.1

cl. I

55

70

972

60

588

75

9.4

cl. I

55

70

2200

611

13

127

59

6.9

cl. I

55

70

1400

3150

875

18

177

64

10.2

cl. I

55

70

1400

4300

1194

13

127

66

11.2

cl. I

55

70

0.35/0.20
0.35/0.20

1400

1150

319

12

118

53

6.1

cl. I

55

70

540
560

2.10/1.20
2.25/1.30

2800

3500

972

65

638

75

9.4

cl. I

55

70

220/380
240/415

120
130

0.41/0.24
0.41/0.24

1400

2200

611

15

147

59

6.9

cl. I

55

70

42314

220/380
240/415

185
210

0.62/0.36
0.64/0.37

1400

3150

875

18.4

180

64

10.2

cl. I

55

70

MP 404 T

42324

220/380
240/415

295
330

0.98/0.57
1.00/0.59

1400

4350

1208

18

177

66

11.2

cl. I

55

70

MP 454 T

42335

220/380
240/415

730
780

3.00/1.75
3.00/1.75

1400

6800

1889

34.6

339

66.5

18.5

cl. I

55

70

MP 504 T

42344

220/380
240/415

1100
1200

3.70/2.15
3.70/2.15

1400

8800

2444

37

363

74

19.2

cl. I

55

70

MP 506 T

42334

220/380
240/415

400
430

1.90/1.12
1.90/1.12

1000

6100

1694

17

167

63.5

19.3

cl. I

55

70

MP 604 T 42374**

220/380
240/415

2200
2350

7.6/4.4
7.6/4.4

1400

14500 4028

39.6

388

79.5

28.1

cl. I

55

70

MP 606 T

220/380
240/415

730
760

3.20/1.90
3.20/1.90

1000

10000 2778

18

177

68.5

28.2

cl. I

55

70

2800

2000

556

41

0.29-0.29

1400

1150

319

220-240

520-550 2.60-2.65

2800

3500

42204

220-240

120-130 0.55-0.55

1400

MP 354 M

42214

220-240

240-270 1.15-1.18

MP 404 M

42224

220-240

300-340 1.40-1.45

MP 254 T

42354

220/380
240/415

60
65

MP 302 T

42302

220/380
240/415

MP 304 T

42304

MP 354 T

Product

Code

V ~ 50 Hz

MP 252 M

42252

220-240

MP 254 M

42254

220-240

MP 302 M

42202

MP 304 M

42364

205-230 1.00-1.00
60-65

** not suitable for use with roof terminals

156

Pa

mm
H2O

P max

Rpm

l/s

Delivery

Poles

m3/h

SINGLE PHASE

M: Monophase (Single phase) 220-240 V - 50 Hz


T: Triphase (Three phase) 380 - 415 V - 50Hz

148_187INDUSTRIALE_PG20.qxd:148_187INDUSTRIALE_PG20.qxd

26-01-2011

14:21

Pagina 157

INSTALLATION OR DIRECTLY TO THE OUTSIDE


Dimensions (mm)

nom.

C
E

A
B
D
D3

D1
D2

MP 252
MP 254
MP 302
MP 304
MP 354
MP 404
MP 454
MP 504
MP 506
MP 604
MP 606

250
250
315
315
355
400
450
500
500
630
630

320
320
380
380
450
510
630
630
630
760
760

280
280
330
330
380
430
530
530
530
630
630

C D D1 D2 D3
279
279
308
279
288
308
381
381
381
430
430

256
256
308
308
360
410
460
510
510
610
610

258.5
258.5
310.5
310.5
362.5
412.5
462.5
512.5
512.5
612.5
612.5

264
264
316
316
368
418
468
518
518
618
618

250
250
300
300
350
400
450
500
500
600
600

92
92
94
94
94
114
109
109
109
124
124

8
8
8
8
8
12
12
12
12
12
12

10
10
10
10
10
15
15
15
15
15
15

Accessories (description and data on pages 188-193).


Model

DPU 250 (spacer)


DPU 300 (spacer)
DPU 350 (spacer)
DPU 400 (spacer)
PGR 250 (gravity shutter)
PGR 300 (gravity shutter)
PGR 350 (gravity shutter)
PGR 400 (gravity shutter)
PGR 450/500 MP(gravity shutter)
PGR 600 MP (gravity shutter)
TRA 250 (protective grille)
TRA 300 (protective grille)
TRA 350 (protective grille)
TRA 400 (protective grille)
TRA 450/500 (protective grille)
TRA 600 (protective grille)
Roof terminal with bird guard
Roof terminal with bird guard
Roof terminal with bird guard
Roof terminal with bird guard
Roof terminal with bird guard
Roof terminal with bird guard
Purlin box
Purlin box
Purlin box
Purlin box
Purlin box
Purlin box

Code

Products

52151
52251
52351
52451
50150
50250
50350
50450
50550
50650
51150
51250
51350
51450
51550
51650
9040*
9041*
9042*
9043*
9044*
9045*
9010*
9011*
9012*
9013*
9014*
9015*

42252 - 42254 - 42354


42202 - 42302 - 42204 - 42304
42214 - 42314
42324 - 42224
42252 - 42254 - 42354
42202 - 42204 - 42302 - 42304
42214 - 42314
42224 - 42324
42335 - 42344 - 42334
42364
42252 - 42254 - 42354
42202 - 42204 - 42302 - 42304
42214 - 42314
42224 - 42324
42335 - 42344 - 42334
42374 - 42364
42252 - 42254 - 42354
42202 - 42302 - 42204 - 42304
42214 - 42314
42224 - 42324 - 42335
42344 - 42334
42364
42252 - 42254 - 42354
42202 - 42302 - 42204 - 42304
42214 - 42314
42224 - 42324 - 42335
42344 - 42334
42364

Model

Code

Soaker sheet
Soaker sheet
Soaker sheet
Soaker sheet
Soaker sheet
Soaker sheet
IRM 30 (three-position
single-phase speed
controller)
IRM 40 (three-position
single-phase speed
controller)
IRT 15 (three-position
three-phase speed
controller)
IRT 35 (three-position
three-phase speed
controller)

Products

9020* 42252 - 42254 - 42354


9021* 42202 - 42302
42204 - 42304
9022* 42214 - 42314
9023* 42224 - 42324 - 42335
9024* 42344 - 42334
9025* 42364
12921 42254 - 42204

12922

42252 - 42202
42214 - 42224

42354 - 42304
12923 42314 - 42324
12924

42302- 42335 - 42344


42334 - 42364

IREM 3 (single-phase 12931


42252 - 42204
IREM 5* speed controller) 12932
42214 - 42224
**
IREM 9
12933
* multiple regulation up to max 5 A
** regulates several fans up to max 9 A

* Available only in UK

157

148_187INDUSTRIALE_PG20.qxd:148_187INDUSTRIALE_PG20.qxd

26-01-2011

14:21

Pagina 158

MEDIUM-PRESSURE INDUSTRIAL AXIAL EXTRACTOR FANS SUITABLE FOR DUCTED


Pressure/performance curves
Pa

mmH2O
15

120

90

P (W)
250

Pa

12

200

40

150

30

mmH2O
5

P (W)
75

Pa

mmH2O
30

60

240

24

480

45

180

18

360

MP 254 M

P (W)
600

MP 302 M

ps

ps

ps

MP 252 M

60

100

20

30

120

12

240

30

50

10

15

60

120

500

Pa

1000
270

mmH2O
10

1500

2000
550

qv

MP 304 M

0
2500 m3/h

l/s

300

166

P (W)
150

Pa

600

mmH2O
10

900

1200
333

qv

MP 354 M

0
1500 m3/h

l/s

1500

P (W)
300

Pa

100

2000
370

mmH2O
12.5

2500

3000
770

qv

0
3500 m3/h
l/s

P (W)
500

MP 404 M

120

80

240

45

90

60

180

30

60

40

120

50

200

15

30

20

60

25 2.5

100

500

Pa

1000
270

mmH2O
5

1500

2000
550

qv

MP 254 T

0
2500 m3/h

10

400

75 7.5

300

ps

ps

ps

60

l/s

1500

P (W)
75

Pa

mmH2O
30

2000
550

2500

3000
830

qv

MP 302 T

0
3500 m3/h

0
1000

1800

l/s

P (W)
600

Pa

2600
720

mmH2O
10

3400

4200
1100

qv

0
5000 m3/h
l/s

P (W)
155

MP 304 T

60

240

24

480

80

120

30

45

180

18

360

60

90

20

30

120

12

240

40

60

10

15

60

120

20

30

ps

ps

ps

40

300

Pa

600
166

mmH2O
10

900

1200
333

qv

MP 354 T

0
1500 m3/h

1500

l/s

P (W)
200

Pa

100

2500
690

mmH2O
12.5

3000

3500
970

qv

0
4000 m3/h

800

75 7.5

210

150

15

600

80

50

20

40

25 2.5

MP 404 T

158

550

qv

830

l/s

P (W)
1000

MP 454 T

ps

ps
0

l/s

20

40

0
3500 m3/h

500

qv

0
2500 m3/h

200

120

3000

2000

280

2500

250

1500

10

60

2000

l/s

1000

mmH2O
25

160

1500

500

Pa

P (W)
350

80

ps

2000

0
1000
0

1800

2600
720

3400
qv

4200
1100

140

100

10

400

70

50

200

0
5000 m3/h
l/s

0
0

2000

4000
1000

6000
qv

8000
2000

0
10000m3/h
l/s

148_187INDUSTRIALE_PG20.qxd:148_187INDUSTRIALE_PG20.qxd

26-01-2011

14:21

Pagina 159

INSTALLATION OR DIRECTLY TO THE OUTSIDE


Pressure/performance curves
Pa

mmH2O
30

100

75

P (W)
1250

Pa

mmH2O
15

24

1000

120

18

750

90

50

12

500

25

250

P (W)
350

Pa

mmH2O
50

12

280

400

40

2000

210

300

30

1500

60

140

200

20

1000

30

70

100

10

500

2000

4000
1000

6000

8000
2000

qv

0
10000 m3/h
l/s

Pa

mmH2O
20

160

16

640

120

12

480

800

80

320

400

40

160

P (W)
2500

MP 604 T

ps

MP 506 T

ps

ps

MP 504 T

1500

3000
830

4500
qv

6000
1600

0
7500 m3/h
l/s

0
0

3500

7000
1900

10500
qv

14000
3800

0
17500 m3/h
l/s

P (W)
800

ps

MP 606 T

0
0

2500

5000
1300

7500
qv

10000
2700

0
12500 m3/h
l/s

P= consumption
q= delivery

159