Field Strength H=(0.4*pi*N*Ip)/Le H= N= Ip= Le 1.2566371 1 1 1 Oersted Number of turns A cm Air Core Inductance Lo=(4*pi*N^2*10^-9)/C1 Lo= N= C1= 1.25664E-08 1 Number of turns 1 cm^-1
Flux Density B=(E*10^8)/(4.44*f*N*Ae) B= E= f= N= Ae= 4265.6293 100 5.50E+05 6 0.16 Gauss Volts(rms) Hertz Number of turns cm^2
Number of turns N=SQRT((L*10^9)/Al)) N= L= Al= 12 Number of turns 1 Henries 2725 Inductance factor
Effective Core Parameters C1=sum(L)/A cm^-1 C1= 1 cm^-1 L 1 cm A 1 cm^2 C2=sum(L)/A^2 C2= L= A= Le=C1^2/C2 Le= C1= C2= Ae=C1/C2 Ae= C1= C2= Ve=C1^3/C2^2 Ve= C1= C2= cm^-3 1 cm^-3 1 cm 1 cm^2 cm 1 cm 1 cm^-1 1 cm^-3 cm^2 1 cm^2 1 cm^-1 1 cm^-3 cm^3 1 cm^3 1 cm^-1 1 cm^-3
Effective Permeability ue=Le/(Le/ui+L) ue= Le= ui= L= 0.5 1 1 1 effective permeability Effective path length initial permeability Air gap length
Q factor Q=2*pi*f*Ls/Rs Q= f= Ls= Rs= Q= f= Lp= Rp= 6.283185307 1 Hertz 1 Henries 1 Ohms 0.159154943 1 Hertz 1 Henries 1 Ohms
Enter Core Material Properties Here =J Ae (cm^2) 0.243 Affective Area Ie (cm) 5.2 Magnetic Path Length Al (nH/N^2) 1175 Nanohenries/Turn^2
* *
Application Considerations RMS Load Power E(volts) Load impedance Lowest Operating Frequency
Bsat Hsat
2800 Saturation Flux density for material chosen 12.6 Saturation Flux intensity for material chosen
Flux Density Saturation Test Bpeak 2531.0576 Gauss Flux intensity Saturation Test Hpeak 11.377257 * dc current
Highest Operating Frequency Midband Frequency Peak current Peak voltage Loss calculations Low Frequency Loss Mid Band Loss High Frequency Loss
Original spreadsheet work by Fabian Hartery, B.Eng fabian_hartery@yahoo.ca For the design of transformer magnetics and core selection as derived from Fair-Rite Soft Ferrites Data Book Dexter Magnetics http://www.fair-rite.com/newfair/pdf/Fair-Rite_Catalog_16th_Edition_Rev_03_2012.pdf
Inductance L=N^2/Al L= N= Al= 0.013211009 Henries 6 Number of turns 2725 Inductance factor
Number of turns
L=10^-9*ui*((4*pi*N^2)/C1) L= ui= N= C1= 0.009047787 5000 12 1 Henries initial permeability Number of turns cm^-1 Henries Henries effective permeability Number of turns cm^-1
Number of turns
nductance factor
Attenuation Loss=20log(abs(Zs+Zl+Zsc)/Zs+Zl) Loss= Zs= Zl= Zsc= 3.521825181 1 1 1 dB Ohms Ohms Ohms
dB
oss calculations ow Frequency Loss Mid Band Loss High Frequency Loss
0.053288 dB 0.107901 dB
*determined by shunt inductance *determined by winding resistance when loss of shunt inductance is neglible *determined by leakage losses
tance is neglible