Академический Документы
Профессиональный Документы
Культура Документы
2010 Edition
Nuclear Power
Reactors
in the World
CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Table 16.
Table 17.
Table 18.
5
7
10
12
13
14
16
18
21
22
24
25
25
26
29
32
48
49
54
59
60
61
62
63
65
66
72
75
76
77
78
79
80
INTRODUCTION
This is the thirtieth edition of Reference Data Series
No. 2, Nuclear Power Reactors in the World, which is
published once per year, to present the most recent
reactor data available to the Agency. It contains the
following summarized information:
General and technical information as of the end of 2009
on power reactors operating or under construction, and
shut down;
Performance data on reactors operating in the Agency's
Member States, as reported to the IAEA.
The Agency's Power Reactor Information System
(PRIS) is a comprehensive data source on nuclear power
reactors in the World. It includes specification and
performance history data of operating reactors as well as
reactors under construction or reactors being
decommissioned. PRIS data are collected by the Agency
through the designated national correspondents of
Member States.
PRIS outputs are available in the annual publications
and on the PRIS web site (http://www.iaea.org/pris). Detail
outputs are accessible to registered users through on-line
applications. Enquiries should be addressed to:
Director
Division of Nuclear Power
International Atomic Energy Agency
Vienna International Centre
PO Box 100
1400 Vienna, Austria
Email: PrisAdmin@iaea.org
DEFINITIONS
Performance factors
EAF (%) =
UCF (%) =
UCL (%) =
PCL (%) =
LF (%)
OF (%)
100
100
100
100
100
On-line Hours
Total Hours
100
where
EAF
UCF
UCL
PCL
LF
OF
REG
PEL
UEL
XEL
EG
the net electrical energy supplied during the reference period as measured at the unit outlet
terminals, i.e. after deducting the electrical
energy taken by unit auxiliaries and the losses
in transformers that are considered integral
parts of the unit.
Construction Start
Date when first major placing of concrete, usually for the
base mat of the reactor building, is done.
First Criticality
Date when the reactor is made critical for the first time.
Grid Connection
Date when the plant is first connected to the electrical grid
for the supply of power. After this date, the plant is considered to be in operation.
Commercial Operation
Date when the plant is handed over by the contractors to
the owner and declared officially in commercial
operation.
Permanent Shutdown
Date when the plant is officially declared to be shut down
by the owner and taken out of operation permanently.
8
Long-term Shutdown
A unit is considered in the long-term shutdown status, if it
has been shut down for an extended period (usually several years) without any firm recovery schedule at the
beginning but there is the intention to re-start the unit
eventually.
Units and Energy Conversion
1 terawatt-hour [TWh] = 106 megawatt-hours [MWh].
For an average power plant,
1 TWh = 0.39 megatonnes of coal equivalent (input)
= 0.23 megatonnes of oil equivalent (input).
10
ARGENTINA
ARMENIA
BELGIUM
BRAZIL
BULGARIA
CANADA
CHINA
CZECH REP.
FINLAND
FRANCE
GERMANY
HUNGARY
INDIA
IRAN,ISL.REP.
JAPAN
KOREA REP.
MEXICO
NETHERLANDS
PAKISTAN
ROMANIA
RUSSIA
SLOVAKIA
SLOVENIA
SOUTH AFRICA
SPAIN
SWEDEN
SWITZERLAND
UK
Country
935
375
5902
1884
1906
12569
8438
3678
2696
63260
20480
1889
3987
46823
17705
1300
487
425
1300
21743
1762
666
1800
7450
9036
3238
10137
54
20
2
1
2
2
31
4
1
2
8
10
5
19
Total
MW(e)
2
1
7
2
2
18
11
6
4
59
17
4
18
No of
Units
Reactors in Operation
No of
Units
246
2726
Total
MW(e)
1600
1600
2708
915
1325
6520
300
6996
782
1
1
5
1
1
6
1
9
2
1906
19920
2
20
692
Total
MW(e)
No of
Units
TABLE 1. REACTORS IN OPERATION, LONG-TERM SHUTDOWN AND UNDER CONSTRUCTION, 31 DEC. 2009
7.59
2.29
44.96
12.22
14.22
85.13
65.71
25.66
22.60
391.75
127.72
14.30
14.75
NA
263.07
141.12
10.11
4.02
2.64
10.82
152.78
13.08
5.46
11.57
50.58
50.04
26.27
62.86
TW(e).h
6.95
44.95
51.65
2.93
35.90
14.83
1.89
33.77
32.87
75.17
26.12
42.98
2.16
NA
28.89
34.79
4.80
3.70
2.74
20.62
17.82
53.50
37.83
4.84
17.49
37.43
39.50
17.92
% of
Total
Nuclear Electricity
Supplied in 2009
11
437
Total
370705
13107
100747
Total
MW(e)
2972
Total
MW(e)
39.89 TW.h of nuclear electricity generation, representing 20.65% of the total electricity generated there;
Taiwan, China
10.03 TW.h of nuclear electricity generation, representing 76.23% of the total electricity generated there;
Lithuania
No of
Units
Note: The total includes the following data from Lithuania and Taiwan, China:
15
104
No of
Units
Reactors in Operation
UKRAINE
USA
Country
55
2
1
No of
Units
50929
1900
1165
Total
MW(e)
2558.08
77.95
796.89
TW(e).h
NA
48.59
20.17
% of
Total
Nuclear Electricity
Supplied in 2009
TABLE 1. REACTORS IN OPERATION, LONG-TERM SHUTDOWN AND UNDER CONSTRUCTION, 31 DEC. 2009 continued
12
487
300
10964
1762
666
1800
5940
2793
1700
1188
13107
66945
1
1
15
4
1
2
6
3
3
1
15
69
244661
19286
14983
24
16
265
7138
3678
976
63130
14023
1889
9
6
2
58
11
4
MW(e)
375
5902
1884
1906
PWR
1
7
2
2
No.
92
83548
33802
35
1300
1510
6243
1538
300
27537
2
30
2
7
2
6457
MW(e)
1720
BWR
No.
TOTAL
ARGENTINA
ARMENIA
BELGIUM
BRAZIL
BULGARIA
CANADA
CHINA
CZECH REP.
FINLAND
FRANCE
GERMANY
HUNGARY
INDIA
JAPAN
KOREA REP.
MEXICO
NETHERLANDS
PAKISTAN
ROMANIA
RUSSIA
SLOVAKIA
SLOVENIA
SOUTH AFRICA
SPAIN
SWEDEN
SWITZERLAND
UK
UKRAINE
USA
Country
18
18
No.
GCR
8949
8949
MW(e)
45
1
2
16
18
2
22638
125
1300
2722
3687
12569
1300
935
PHWR
No.
MW(e)
15
15
10219
10219
LWGR
No.
MW(e)
TABLE 2. TYPE AND NET ELECTRICAL POWER OF REACTORS CONNECTED TO THE GRID, 31 DEC. 2009
No.
FBR
690
560
130
MW(e)
437
2
1
7
2
2
18
11
6
4
59
17
4
18
54
20
2
1
2
2
31
4
1
2
8
10
5
19
15
104
No.
Total
370705
935
375
5902
1884
1906
12569
8438
3678
2696
63260
20480
1889
3987
46823
17705
1300
487
425
1300
21743
1762
666
1800
7450
9036
3238
10137
13107
100747
MW(e)
13
46
43719
6520
300
5277
782
1900
1165
6
1
7
2
2
1
MW(e)
1906
19920
1600
1600
1834
915
PWR
2
20
1
1
2
1
No.
TOTAL
ARGENTINA
BULGARIA
CHINA
FINLAND
FRANCE
INDIA
IRAN,ISL.REP.
JAPAN
KOREA REP.
PAKISTAN
RUSSIA
SLOVAKIA
UKRAINE
USA
Country
(*) 3
No.
BWR
3925
1325
MW(e)
No.
PHWR
1096
404
692
MW(e)
No.
LWGR
TABLE 3. TYPE AND NET ELECTRICAL POWER OF REACTORS UNDER CONSTRUCTION, 31 DEC. 2009
915
915
MW(e)
No.
FBR
1274
804
470
MW(e)
55
1
2
20
1
1
5
1
1
6
1
9
2
2
1
No.
Total
50929
692
1906
19920
1600
1600
2708
915
1325
6520
300
6996
782
1900
1165
MW(e)
14
ARGENTINA
ARMENIA
BELGIUM
BRAZIL
BULGARIA
CANADA
CHINA
CZECH REP.
FINLAND
FRANCE
GERMANY
HUNGARY
INDIA
ITALY
JAPAN
KAZAKHSTAN
KOREA REP.
LITHUANIA
MEXICO
NETHERLANDS
PAKISTAN
ROMANIA
RUSSIA
SLOVAKIA
SLOVENIA
SOUTH AFRICA
SPAIN
SWEDEN
Country
935
375
5902
1884
1906
12569
8438
3678
2696
63260
20480
1889
3987
46823
17705
1300
487
425
1300
21743
1762
666
1800
7450
9036
2
1
7
2
2
18
11
6
4
59
17
4
18
54
20
2
1
2
2
31
4
1
2
8
10
Reactors Connected
to the Grid
Capacity
No
MW(e) Net
Long-term Shutdown
Reactors
Capacity
No
MW(e) Net
246
2726
3659
5879
1423
1618
52
11
19
4
5
1
55
786
909
621
1210
1
5
3
2
3
2370
1632
478
4
3
376
10
1
1
Permanently Shutdown
Reactors
Capacity
No
MW(e) Net
No
2
2
8
2
6
25
11
6
4
70
36
4
18
4
60
1
20
2
2
2
2
2
36
7
1
2
10
13
935
751
5912
1884
3538
15773
8438
3678
2696
66919
26359
1889
3987
1423
48687
52
17705
2370
1300
542
425
1300
22529
2671
666
1800
8071
10261
62
35
233
37
147
582
99
110
123
1700
751
98
318
81
1440
25
339
43
35
65
47
15
994
132
28
50
269
372
10
11
7
7
3
3
6
6
8
10
7
6
11
7
8
7
3
3
2
3
10
4
2
5
2
5
Total, Operating
and Shutdown Reactors
Experience
Capacity
MW(e) Net
Years
Months
15
437
Total
370705
3238
10137
13107
100747
Long-term Shutdown
Reactors
Capacity
No
MW(e) Net
2. Operating Experience is counted from the grid connection excluding a long-term shutdown period.
reactors connected to the grid: 6 units, 4980 MW, 170 years 1 month.
Notes:
5
19
15
104
Reactors Connected
to the Grid
Capacity
No
MW(e) Net
SWITZERLAND
UK
UKRAINE
USA
Country
2972
123
26
4
28
3301
3515
9764
37658
Permanently Shutdown
Reactors
Capacity
No
MW(e) Net
No
565
5
45
19
132
411350
3238
13438
16622
110511
13913
173
1457
368
3499
10
8
6
11
Total, Operating
and Shutdown Reactors
Experience
Capacity
MW(e) Net
Years
Months
16
ARGENTINA
ARMENIA
BELGIUM
BRAZIL
BULGARIA
CANADA
CHINA
CZECH REP.
FINLAND
FRANCE
GERMANY
HUNGARY
INDIA
ITALY
JAPAN
KAZAKHSTAN
KOREA REP.
LITHUANIA
MEXICO
NETHERLANDS
PAKISTAN
ROMANIA
RUSSIA
SLOVAKIA
SLOVENIA
SOUTH AFRICA
SPAIN
SWEDEN
SWITZERLAND
Country
335
816
1670
1224
5172
2208
14388
10323
832
1112
14918
135
564
498
125
8596
780
1073
5510
1940
3
10
4
22
19
4
4
23
1
1
2
1
20
2
3
8
4
MW(e)
1
2
4
No.
1980
28
4
1
2
8
12
5
15841
1632
632
1840
5608
9455
2881
508
137
391
2300
37478
18110
825
1143
1273
23612
135
3580
1380
1
4
43
24
2
6
3
33
1
5
1
2
1
935
816
5464
626
1632
9741
18898
1632
620
1840
7099
9819
2942
30867
135
7220
2760
640
539
125
41
1
9
2
1
2
1
29
4
1
2
9
12
5
1632
2310
55808
21250
1710
1324
5501
626
2585
13993
7
1
5
20
4
4
56
21
4
7
935
30
4
1
2
9
12
5
50
1
11
2
2
2
1
2
1
7
1
6
21
3
4
4
56
19
4
10
19848
1632
620
1840
7097
10043
3056
39625
50
9115
2370
1256
510
125
935
376
5631
626
3538
14902
2188
1782
2310
58573
20972
1729
1746
43245
12990
2370
1290
449
425
655
19848
2440
676
1840
7468
9412
3170
16
2
2
1
2
1
30
6
1
2
9
11
5
978
376
5712
1976
3760
9998
2188
2611
2656
63080
21283
1729
2508
52
2
1
7
2
6
14
3
5
4
59
19
4
14
20
1
2
1
2
1
31
6
1
2
9
10
5
55
2
1
7
2
4
18
9
6
4
59
17
4
15
16810
1185
1360
450
425
655
21743
2442
656
1800
7591
8905
3220
47593
935
376
5801
1901
2722
12584
6587
3373
2676
63260
20339
1755
2993
Number of Units and Net Capacity (MW(e)) Connected to the Grid at 31st Dec. of Each Year
1990
1995
2000
2005
MW(e)
No.
MW(e)
No.
MW(e)
No.
MW(e)
No.
MW(e)
2
2
8
1
4
16
No.
1985
20
1
2
1
2
2
31
4
1
2
8
10
5
55
2
1
7
2
2
18
11
6
4
59
17
4
17
No.
2008
17647
1185
1300
482
425
1300
21743
1711
666
1800
7450
8996
3220
47278
935
376
5824
1766
1906
12577
8438
3634
2696
63260
20470
1859
3782
MW(e)
17705
1300
487
425
1300
21743
1762
666
1800
7450
9036
3238
46823
935
375
5902
1884
1906
12569
8438
3678
2696
63260
20480
1889
3987
MW(e)
2
1
2
2
31
4
1
2
8
10
5
2009
20
54
2
1
7
2
2
18
11
6
4
59
17
4
18
No.
17
245
WORLD
1980
133017
6423
2286
50881
MW(e)
363
38
10
90
No.
1985
245667
10077
8324
74401
318246
11360
13020
96228
434
35
15
108
341402
12910
13045
98068
435
33
13
103
349999
12490
11195
96297
441
23
15
103
368125
11852
13107
98145
438
19
15
104
No.
2008
371562
10097
13107
100683
MW(e)
- 1980: 2 units, 1208 MW, 1985: 6 units, 4890 MW, 1990: 6 units, 4828 MW, 1995: 6 units, 4884 MW, 2000: 6 units, 4884 MW, 2005: 6 units, 4884 MW, 2008: 6 units, 4949 MW, 2009: 6 units, 4980 MW.
416
37
15
108
Number of Units and Net Capacity (MW(e)) Connected to the Grid at 31st Dec. of Each Year
1990
1995
2000
2005
MW(e)
No.
MW(e)
No.
MW(e)
No.
MW(e)
No.
MW(e)
Note: The world total includes the following data in Taiwan, China:
33
3
69
No.
UK
UKRAINE
USA
Country
TABLE 5. OPERATING REACTORS AND NET ELECTRICAL POWER, 1980 TO 2009 continued
437
19
15
104
No.
2009
370705
10137
13107
100747
MW(e)
18
ARGENTINA
ARMENIA
BELGIUM
BRAZIL
BULGARIA
CANADA
CHINA
CZECH REP.
FINLAND
FRANCE
GERMANY
HUNGARY
INDIA
ITALY
JAPAN
KAZAKHSTAN
KOREA REP.
LITHUANIA
MEXICO
NETHERLANDS
PAKISTAN
ROMANIA
RUSSIA
SLOVAKIA
SLOVENIA
SOUTH AFRICA
SPAIN
SWEDEN
SWITZERLAND
Country
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
0.5
NA
NA
NA
NA
NA
2.18
11.86
5.71
38.02
6.68
57.31
41.44
2.77
2.11
79.11
3.26
3.97
0.07
43.78
4.52
4.98
25.42
13.63
88.26
8.70
3.85
5.39
26.83
55.89
21.28
3.69
0.26
NA
NA
NA
4.2
24.0
42.3
39.8
6.1
1.0
23.2
NA
NA
38.2
64.8
31.2
23.6
2.2
3.8
22.7
1.99
17.98
213.26
119.59
6.10
3.87
6.46
145.37
12.14
8.75
59.8
1.7
31.6
12.7
11.7
29.25
3.17
12.17
59.47
5.25
109.62
11.16
4.39
8.47
51.98
65.27
22.40
NA
NA
NA
5.6
35.9
45.9
42.6
49.1
NA
2.6
4.9
1.1
27.1
187.19
50.26
15.70
2.78
3.29
0.38
NA
35.1
74.5
33.1
51.4
2.2
60.1
1.0
35.7
14.8
19.8
11.77
18.13
297.61
139.37
12.89
5.29
40.59
2.06
13.51
69.87
6.72
91.59
11.35
4.57
11.29
53.49
67.19
23.58
274.71
0.08
60.21
10.64
7.53
3.78
0.46
39.30
2.33
16.22
93.98
12.13
12.23
18.13
358.71
146.13
13.20
6.99
6.57
11.8
44.1
39.5
6.5
34.1
46.6
39.9
33.4
0.1
36.1
86.1
6.0
4.9
0.9
55.5
1.0
46.4
17.3
1.2
20.0
29.9
76.1
29.6
42.3
1.9
11.8
103.54
7.42
7.92
3.70
0.90
5.05
120.10
15.17
4.55
13.00
59.49
51.88
25.05
305.67
5.74
1.84
45.81
5.59
16.79
69.12
16.02
12.71
21.58
395.39
160.66
13.35
14.23
40.7
73.9
3.9
4.3
1.7
10.9
15.0
53.4
37.4
6.6
27.6
39.0
38.2
33.8
7.3
33.0
56.8
1.9
45.0
11.8
1.2
18.7
32.2
76.4
30.6
40.6
3.1
137.59
9.54
10.32
3.77
2.41
5.11
137.64
16.34
5.61
12.24
54.99
69.65
22.11
280.50
6.37
2.50
45.34
9.20
17.38
86.83
50.33
23.25
22.36
431.18
154.61
13.02
15.73
44.7
70.3
5.0
3.9
2.8
8.6
15.8
56.1
42.4
5.5
19.6
44.9
38.0
29.3
6.9
42.7
55.6
2.5
44.1
14.5
2.0
30.5
32.9
78.5
31.1
37.2
2.8
144.25
9.14
9.36
3.93
1.74
10.33
152.06
15.45
5.97
12.75
56.45
61.34
26.27
241.25
6.85
2.27
43.36
13.21
14.74
88.30
65.32
25.02
22.05
419.80
140.89
13.87
13.18
35.6
72.9
4.0
3.8
1.9
17.5
16.9
56.4
41.7
5.3
18.3
42.0
39.2
24.9
6.2
39.4
53.3
3.1
32.9
14.8
2.2
32.5
29.7
76.2
28.8
37.2
2.0
141.12
10.03
10.11
4.02
2.64
10.82
152.78
13.08
5.46
11.57
50.58
50.04
26.27
263.07
7.59
2.29
44.96
12.22
14.22
85.13
65.71
25.66
22.60
391.75
127.72
14.30
14.75
34.8
76.2
4.8
3.7
2.7
20.6
17.8
53.5
37.8
4.8
17.5
37.4
39.5
28.9
7.0
45.0
51.7
2.9
35.9
14.8
1.9
33.8
32.9
75.2
26.1
43.0
2.2
Nuclear production (TW(e).h) of reactors connected to the Grid at 31st Dec. of the year
1980
1985
1990
1995
2000
2005
2008
2009
TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total
19
635.36
WORLD
NA
NA
NA
1327.19
53.73
35.81
378.68
19.6
NA
15.5
1890.35
58.77
71.26
578.08
19.7
NA
20.6
2190.13
70.64
65.78
673.52
2009: 39.89 TW.h of nuclear electricity generation, representing 20.65% of the total electricity generated there
2008: 39.3 TW.h of nuclear electricity generation, representing 17.45% of the total electricity generated there
2005: 38.4 TW.h of nuclear electricity generation, representing 17.93% of the total electricity generated there
2000: 37 TW.h of nuclear electricity generation, representing 21.19% of the total electricity generated there
1995: 33.8 TW.h of nuclear electricity generation, representing 28.79% of the total electricity generated there
1990: 31.54 TW.h of nuclear electricity generation, representing 38.32% of the total electricity generated there
Note: The world total includes the following data from Taiwan, China:
32.32
6.38
249.84
25.4
37.8
22.5
2440.37
72.99
72.56
755.55
21.9
47.3
19.8
2626.41
75.34
83.40
783.35
20.0
48.5
19.3
2597.81
48.21
84.47
806.68
13.0
47.4
19.6
2558.08
62.86
77.95
796.89
17.9
48.6
20.2
Nuclear production (TW(e).h) of reactors connected to the Grid at 31st Dec. of the year
1980
1985
1990
1995
2000
2005
2008
2009
TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total TW(e).h % of Total
UK
UKRAINE
USA
Country
TABLE 6. NUCLEAR ELECTRICITY PRODUCTION AND SHARE FROM 1980 TO 2009 continued
Year
Construction
Starts
Design
Number
Capacity
of Units
MW(e)
Connections
to the Grid
Design
Number
Capacity
of Units
MW(e)
Reactors
in operation
Updated
Number
Capacity
of Units
MW(e)
1954
1955
1
8
60
260
1
1
5
5
1956
1957
1958
1959
1960
5
13
6
7
11
577
1836
476
976
1010
1
3
1
5
4
35
119
35
176
438
2
5
6
11
15
65
209
269
548
1010
1961
1962
1963
1964
1965
7
7
5
9
9
1531
1373
1722
2866
3291
1
9
9
8
8
15
955
500
1022
1879
16
25
33
40
48
1026
2105
2537
3538
5742
1966
1967
1968
1969
1970
15
25
32
16
36
7052
16287
22606
11839
24653
8
11
6
10
6
1530
2165
1014
3670
3410
55
64
68
78
84
7335
9369
10388
14058
17579
1971
1972
1973
1974
1975
17
31
31
36
37
11206
23993
25852
32809
35518
16
16
20
26
15
7711
8880
12727
17149
10236
99
113
132
154
169
24314
32975
43672
60994
70414
1976
1977
1978
1979
1980
44
25
23
28
20
42749
23865
21735
23909
19134
19
18
20
8
21
14269
13243
15782
6909
15088
186
200
219
225
245
84024
96388
111925
117814
133017
1981
1982
1983
1984
1985
16
19
16
10
20
15149
19765
12218
9528
16286
23
19
23
33
33
20389
15288
19253
30953
31042
267
284
306
336
363
153832
168377
187656
218452
245667
1986
1987
1988
1989
1990
8
13
7
6
5
6471
11019
7722
4018
3366
27
22
14
12
10
27212
22191
13621
10457
10543
389
407
416
420
416
272012
295812
305212
311942
318246
1991
1992
1993
1994
1995
2
3
4
2
2246
3105
3715
1330
4
6
9
5
5
3668
4809
9012
4176
3635
415
418
427
429
434
321924
325261
333914
336934
341402
1996
1997
1998
1999
2000
1
5
3
4
6
610
4386
2096
4583
5379
6
3
4
4
6
7080
3568
3152
2704
3063
438
434
430
432
435
347296
347895
344915
347368
349999
2001
2002
2003
2004
2005
1
6
1
2
3
1304
3440
202
1336
2900
3
6
2
5
4
2696
4998
1700
4785
3923
438
439
437
438
441
352730
357255
359806
364693
368125
2006
2007
2008
2009
4
8
10
11
3374
6519
10499
12154
2
3
1435
1785
1068
435
439
438
437
369671
371758
371562
370705
21
22
ARGENTINA
ARMENIA
BELGIUM
BRAZIL
BULGARIA
CANADA
CHINA
CZECH REP.
FINLAND
FRANCE
GERMANY
HUNGARY
INDIA
ITALY
JAPAN
KOREA REP.
LITHUANIA
MEXICO
PAKISTAN
ROMANIA
RUSSIA
SLOVAKIA
SLOVENIA
SOUTH AFRICA
SPAIN
SWEDEN
SWITZERLAND
UK
Country
73
87
69
63
66
68
152
101
61
63
74
89
85
63
106
1
4
4
13
9
1
1
11
1
6
2
3
1
4
1976
to
1980
No. Months
73
99
80
102
112
74
125
186
46
65
80
10
4
1
9
2
1
2
5
4
1
6
68
100
112
154
74
24
7
2
2
80
132
104
98
109
4
1
1
7
1981
to
1985
No. Months
98
96
72
49
62
116
151
86
103
90
152
93
89
101
8
4
1
1
15
6
2
1
1
5
1986
to
1990
No. Months
80
109
210
1
1
46
61
120
93
113
97
73
10
2
1
2
3
1991
to
1995
No. Months
1
1
3
5
119
83
169
42
59
122
124
167
176
1996
to
2000
No. Months
4
4
6
1
233
47
54
64
60
191
2001
to
2005
No. Months
TABLE 8. NUMBER OF NEW REACTORS CONNECTED TO THE GRID AND MEDIAN OF CONSTRUCTION TIME SPAN
161
68
80
2006
to
2008
No. Months
53
88
No. Months
2009
23
86
TOTAL
74
89
95
131
7
25
99
64
115
1981
to
1985
No. Months
85
6
22
95
57
144
1986
to
1990
No. Months
Note: Construction time is from the first pouring of concrete to the connection of the unit to the grid.
3
18
1976
to
1980
No. Months
UKRAINE
USA
Country
29
1
1
103
113
221
1991
to
1995
No. Months
23
1
123
278
1996
to
2000
No. Months
20
2
64
227
2001
to
2005
No. Months
80
2006
to
2008
No. Months
TABLE 8. NUMBER OF NEW REACTORS CONNECTED TO THE GRID AND MEDIAN OF CONSTRUCTION TIME SPAN continued
71
No. Months
2009
24
KR -26
RU -162
KOREA REP.
RUSSIA
Reactor
NOVOVORONEZH 2-2
SHIN-KORI-4
SANMEN 1
SANMEN 2
YANGJIANG 2
HONGYANHE 3
HONGYANHE 4
HAIYANG 1
FANGJIASHAN 2
FUQING 2
TAISHAN 1
Name
CN -16
CN -17
CN -19
CN -22
CN -23
CN -24
CN -29
CN -31
CN -34
Code
CHINA
Country
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
Type
VVER AES-2
APR-1400
AP-1000
AP-1000
CPR-1000
CPR-1000
CPR-1000
AP-1000
CPR-1000
CPR-1000
EPR
Model
3200
3938
3415
3415
2905
2905
2905
3415
2905
2905
4500
1200
1400
1115
1115
1087
1080
1080
1115
1087
1087
1750
Gross
1114
1340
1000
1000
1000
1000
1000
1000
1000
1000
1700
Net
Thermal
REA
KHNP
SMNPC
SMNPC
YJNPC
LHNPC
LHNPC
SNPC
QNPC
FQNP
TNPC
Operator
ROSATOM
DHICKOPC
WH/MHI
WH/MHI
DFEC
DFEC
DFEC
WH
DFEC
DFEC
AREVA
NSSS
Supplier
2009-7
2009-9
2009-4
2009-12
2009-6
2009-3
2009-8
2009-9
2009-7
2009-6
2009-10
Construction
start
Grid
Connection
2014-9
Commercial
Operation
25
JP -64
JAPAN
Reactor
TOMARI-3
RAJASTHAN-5
Name
Model
PWR
M (3-loop)
Type
SHIN-KORI-1
VOLGODONSK-2
IR -1
KR -21
RU -62
IRAN,ISL.REP.
KOREA REP.
RUSSIA
During 2010, 7 reactors (4839 MW) are expected to achieve grid connection.
BUSHEHR 1
KAIGA-4
RAJASTHAN-6
IN -16
IN -20
INDIA
Reactor
LINGAO 3
QINSHAN 2-3
Name
CN -12
CN -14
Code
CHINA
Country
M310
CNP600
Model
PWR
PWR
PWR
VVER V-320I
OPR-1000
VVER V-446
PWR
PWR
Type
912
220
866
202
Net
3200
2825
3000
800
801
2905
1930
Thermal
1000
1000
1000
220
220
1087
650
Gross
950
960
915
202
202
1000
610
Net
MHI
REA
KHNP
NPPDCO
NPCIL
NPCIL
LDNPC
NPQJVC
ROSATOM
DHICKOPC
ASE
NPCIL
NPCIL
DFEC
CNNC
NSSS
Supplier
NPCIL
NSSS
Supplier
Operator
HEPCO
NPCIL
Operator
2660
801
Gross
Capacity [MW]
Thermal
During 2009, 2 reactors (1068 MW) were newly connected to the grid.
IN -19
Code
INDIA
Country
1983-5
2006-6
1975-5
2002-5
2003-1
2005-12
2006-3
Construction
Start
2004-11
2002-9
Construction
Start
2010-1
2010-7
2010-5
2010-3
2010-1
2010-7
2010-11
First
Criticality
2009-3
2009-11
First
Criticality
Grid Connection
2010-3
2010-8
2010-7
2010-4
2010-3
2010-8
2010-12
Grid
Date
2009-3
2009-12
26
CN -42
CN -51
CN -52
CN -53
CN -54
CN -55
CN -56
CN -57
CN -58
CN -59
CN -60
CN -47
CN -48
CN -49
CN -50
CN -25
CN -26
CN -27
CN -65
CN -66
CN -67
CN -68
CN -38
CN -39
CN -61
CN -62
CN -63
CHINA
Code
BR -3
BRAZIL
Country
Name
BAMAOSHAN
CHANGJIANG 1
CHANGJIANG 2
CHANGJIANG 3
CHANGJIANG 4
FANGCHENGGANG 1
FANGCHENGGANG 2
FANGCHENGGANG 3
FANGCHENGGANG 4
FANGCHENGGANG 5
FANGCHENGGANG 6
FUQING 3
FUQING 4
FUQING 5
FUQING 6
HAIYANG 2
HONGSHIDING 1
HONGSHIDING 2
JIYANG 1
JIYANG 2
JIYANG 3
JIYANG 4
NINGDE 3
NINGDE 4
PENGZE 1
PENGZE 2
PENGZE 3
ANGRA-3
Reactor
PWR
PWR
PWR
PWR
PWR
PWR
PWR
Type
M310
M310
2905
2905
1080
1080
1087
1087
1087
1087
1000
2905
2905
2905
2905
CPR-1000
CPR-1000
CPR-1000
CPR-1000
AP1000
1350
Gross
1080
3765
Thermal
CRP-1000
Model
Net
1000
1000
1000
1000
1000
1000
1250
1250
1250
900
650
650
650
650
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1245
DFEC
DFEC
HONGYANH
NDNPC
DFEC
DFEC
DFEC
DFEC
WH
KWU
NSSS
Supplier
FQNP
FQNP
FQNP
FQNP
ELETRONU
Operator
2010-1
Expected
Construction
Start
27
IR -2
IR -5
IR -9
JP -70
JP -71
JP -69
JP -74
JP -72
JP -62
JP -63
JP -73
JP -66
JP -67
JP -68
KR -27
KR -28
JAPAN
KOREA REP.
SHIN-ULCHIN-1
SHIN-ULCHIN-2
FUKUSHIMA-DAIICHI-7
FUKUSHIMA-DAIICHI-8
HIGASHI DORI 1 (TEPCO)
HIGASHI DORI 2 (TEPCO)
HIGASHI DORI 2 (TOHOKU)
KAMINOSEKI 1
KAMINOSEKI 2
NAMIE-ODAKA
OHMA
TSURUGA-3
TSURUGA-4
BUSHEHR 2
BUSHEHR 3
DARKHOVAIN
Name
PENGZE 4
SHIDAOWAN 1
TAISHAN 2
TAOHUAJIANG 1
TAOHUAJIANG 2
XIANNING 1
XIANNING 2
YANGJIANG 3
YANGJIANG 4
YANGJIANG 5
YANGJIANG 6
Code
Reactor
CN -64
CN -69
CN -35
CN -32
CN -33
CN -40
CN -41
CN -43
CN -44
CN -45
CN -46
IRAN,ISL.REP.
Country
PWR
PWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
Type
APR-1400
APR-1400
3926
3926
3926
3926
ABWR
ABWR
ABWR
ABWR
ABWR
ABWR
ABWR
BWR
ABWR
APWR
APWR
3938
3983
3926
4466
4466
3000
3000
1113
2905
2905
2905
2905
CPR1000
CPR1000
CPR1000
CPR1000
VVER
TBD
IR-360
4500
Thermal
1400
1400
1383
1538
1538
1373
1373
1380
1380
1385
1385
1000
1000
360
1087
1087
1087
1087
1750
Gross
Capacity [MW]
EPR
Model
TABLE 12. REACTORS PLANNED FOR CONSTRUCTION AS KNOWN AT 31 DEC. 2009 continued
Net
1340
1340
825
1325
1339
1339
1343
1343
1067
915
915
330
1000
1000
1000
1000
1250
200
1700
KHNP
KHNP
TEPCO
TEPCO
TEPCO
TEPCO
TOHOKU
CHUGOKU
CHUGOKU
TOHOKU
J-POWER
JAPCO
JAPCO
NPPDCO
NPPDCO
NPPDCO
YJNPC
YJNPC
YJNPC
YJNPC
Operator
DHICKOPC
DHICKOPC
H/G
MHI
MHI
TBD
ASE
DFEC
DFEC
DFEC
DFEC
NSSS
Supplier
2011-5
2012-5
2010-10
2010-10
2011-1
2012-1
2011-1
Expected
Construction
Start
28
Name
AKKUYU
KURSK 2-1
LENINGRAD 2-2
LENINGRAD 2-3
VOLGODONSK-3
VOLGODONSK-4
Reactor
TR -1
TURKEY
Code
RU -166
RU -164
RU -165
RU -63
RU -64
RUSSIA
Country
PWR
PWR
PWR
PWR
PWR
PWR
Type
VVER-1100
VVER AES-2006
VVER AES-2006
VVER V320
VVER V320
Model
3200
3200
3200
3200
3200
Thermal
1170
1170
1170
1170
1000
Gross
Capacity [MW]
TABLE 12. REACTORS PLANNED FOR CONSTRUCTION AS KNOWN AT 31 DEC. 2009 continued
Net
1085
1085
1085
1085
950
TEAS
REA
REA
REA
REA
REA
Operator
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
NSSS
Supplier
Expected
Construction
Start
29
AR -3
BG -7
BG -8
CN -28
CN -29
CN -30
CN -31
CN -24
CN -20
CN -21
CN -22
CN -23
CN -12
CN -13
CN -36
CN -37
CN -14
CN -15
CN -16
CN -17
CN -34
CN -18
CN -19
FI -5
FR -74
BULGARIA
CHINA
FINLAND
FRANCE
Code
ARGENTINA
Country
FLAMANVILLE-3
OLKILUOTO-3
FANGJIASHAN 1
FANGJIASHAN 2
FUQING 1
FUQING 2
HAIYANG 1
HONGYANHE 1
HONGYANHE 2
HONGYANHE 3
HONGYANHE 4
LINGAO 3
LINGAO 4
NINGDE 1
NINGDE 2
QINSHAN 2-3
QINSHAN 2-4
SANMEN 1
SANMEN 2
TAISHAN 1
YANGJIANG 1
YANGJIANG 2
BELENE-1
BELENE-2
ATUCHA-2
Name
Reactor
Model
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
EPR
EPR
CPR-1000
CPR-1000
CPR-1000
CPR-1000
AP-1000
CPR-1000
CPR-1000
CPR-1000
CPR-1000
M310
M310
M310
M310
CNP600
CNP 600
AP-1000
AP-1000
EPR
CPR-1000
CPR-1000
VVER V-466
VVER V-466
Type
4300
4300
2905
2905
2905
2905
3415
2905
2905
2905
2905
2905
2905
2905
2905
1930
1930
3415
3415
4500
2905
2905
3000
3000
2160
1650
1720
1087
1087
1087
1087
1115
1080
1080
1080
1080
1087
1086
1087
1080
650
650
1115
1115
1750
1087
1087
1000
1000
745
Gross
1600
1600
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
610
610
1000
1000
1700
1000
1000
953
953
692
Net
Thermal
EDF
TVO
QNPC
QNPC
FQNP
FQNP
SNPC
LHNPC
LHNPC
LHNPC
LHNPC
LDNPC
LDNPC
NDNPC
NDNPC
NPQJVC
NPQJVC
SMNPC
SMNPC
TNPC
YJNPC
YJNPC
KOZNPP
KOZNPP
NASA
Operator
AREVA
AREVA
DFEC
DFEC
DFEC
DFEC
WH
DFEC
DFEC
DFEC
DFEC
DFEC
DFEC
DFEC
DFEC
CNNC
CNNC
WH/MHI
WH/MHI
AREVA
DFEC
DFEC
ASE
ASE
SIEMENS
NSSS
Supplier
2007-12
2005-8
2008-12
2009-7
2008-11
2009-6
2009-9
2007-8
2008-3
2009-3
2009-8
2005-12
2006-6
2008-2
2008-11
2006-3
2007-1
2009-4
2009-12
2009-10
2008-12
2009-6
1987-1
1987-3
1981-7
Construction
Start
2011-12
2010-7
2010-11
2009-12
First Criticality
2012-5
2010-8
2010-12
2011-9
2012-7
Grid
Connection
2011-6
2010-12
2011-3
2012-1
Commercial
Operation
30
PK -3
SK -10
SLOVAKIA
KR -21
KR -22
KR -25
KR -26
KR -23
KR -24
KOREA REP.
RU -151
RU -152
RU -116
RU -37
RU -120
RU -163
RU -161
RU -162
RU -62
JP -65
JAPAN
RUSSIA
IR -1
IRAN,ISL.REP.
PAKISTAN
IN -16
IN -25
IN -26
IN -29
IN -20
Code
INDIA
Country
MOCHOVCE-3
AKADEMIK LOMONOSOV 1
AKADEMIK LOMONOSOV 2
BELOYARSKY-4 (BN-800)
KALININ-4
KURSK-5
LENINGRAD 2-1
NOVOVORONEZH 2-1
NOVOVORONEZH 2-2
VOLGODONSK-2
CHASNUPP 2
SHIN-KORI-1
SHIN-KORI-2
SHIN-KORI-3
SHIN-KORI-4
SHIN-WOLSONG-1
SHIN-WOLSONG-2
SHIMANE-3
BUSHEHR 1
KAIGA-4
KUDANKULAM-1
KUDANKULAM-2
PFBR
RAJASTHAN-6
Name
Reactor
PWR
PWR
PWR
FBR
PWR
LWGR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
BWR
PWR
PHWR
PWR
PWR
FBR
PHWR
Type
VVER V-213
KLT-40S 'Float
KLT-40S 'Float
BN-800
VVER V-320
RBMK-1000
VVER AES-2006
VVER AES-2006
VVER AES-2006
VVER V-320I
PWR
1375
3200
3200
3200
3200
150
150
2100
3200
999
2825
2825
3983
3938
2825
2825
3926
ABWR
OPR-1000
OPR-1000
APR-1400
APR-1400
OPR-1000
OPR-1000
3000
1253
801
800
440
35
35
880
1000
1000
1170
1200
1200
1000
325
1000
1000
1400
1400
1000
1000
1373
1000
220
1000
1000
500
220
Gross
391
32
32
804
950
915
1085
1114
1114
950
300
960
960
1340
1340
960
960
1325
915
202
917
917
470
202
Net
Thermal
VVER V-446
Horizontal Pre
Horizontal Pre
VVER V-412
VVER V-412
Model
ASE
NPCIL
NPCIL
MAEP
MAEP
NSSS
Supplier
EMO
REA
REA
REA
REA
REA
REA
REA
REA
REA
PAEC
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
SKODA
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
CNNC
DHICKOPC
DHICKOPC
DHICKOPC
DHICKOPC
DHICKOPC
DHICKOPC
CHUGOKU HITACHI
NPPDCO
NPCIL
NPCIL
NPCIL
BHAVINI
NPCIL
Operator
1987-1
2007-4
2007-4
2006-7
1986-8
1985-12
2008-10
2008-6
2009-7
1983-5
2005-12
2006-6
2007-6
2008-10
2009-9
2007-11
2008-9
2007-10
1975-5
2002-5
2002-3
2002-7
2004-10
2003-1
Construction
Start
2010-1
2011-4
2010-7
2011-7
2011-5
2012-5
2010-5
2010-3
2010-12
2011-6
2010-1
First Criticality
2010-3
2011-5
2010-8
2011-8
2011-5
2012-5
2011-12
2010-7
2010-4
2011-2
2011-8
2010-3
Grid
Connection
2013-12
2013-12
2013-12
2011-8
2010-12
2011-12
2013-9
2014-9
2011-10
2012-10
2011-12
2010-12
2010-5
2011-3
2011-9
2010-3
Commercial
Operation
31
3425
440
1218
1000
1000
1165
950
950
391
Net
NNEGC
NNEGC
EMO
Operator
ASE
ASE
SKODA
NSSS
Supplier
GE
GE
W (4-loop) (IC
1375
3200
3200
Gross
Thermal
Status as of 31 December 2009, 55 reactors (50929 MW) are under construction, including 2 units (2600 MW) from Taiwan, China.
TAIWAN, CN
TW -7
LUNGMEN 1
BWR ABWR
3926
1350
1300 TPC
TW -8
LUNGMEN 2
BWR ABWR
3926
1350
1300 TPC
TAIWAN, CN
PWR
VVER V-392B
VVER
VVER V-213
Model
WH
WATTS BAR-2
PWR
PWR
PWR
Type
TVA
US -391
USA
KHMELNITSKI-3
KHMELNITSKI-4
MOCHOVCE-4
UA -51
UA -52
SK -11
Reactor
Name
Code
UKRAINE
Country
1999-3
1999-8
1972-12
1986-3
1987-2
1987-1
Construction
Start
2011-1
2012-1
First Criticality
2011-2
2012-2
2012-8
2015-1
2016-1
Grid
Connection
2011-12
2012-12
Commercial
Operation
32
Reactor
ANGRA-1
ANGRA-2
KOZLODUY-5
KOZLODUY-6
BR -1
BR -2
BG -5
BG -6
CA -10
CA -11
CA -18
CA -19
CA -20
CA -21
CA -22
CA -23
CA -24
CA -25
BRAZIL
BULGARIA
CANADA
Model
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
CANDU 750A
CANDU 750A
CANDU 750B
CANDU 750B
CANDU 750B
CANDU 750B
CANDU 850
CANDU 850
CANDU 850
CANDU 850
VVER V-320
VVER V-320
2-loop WE
PRE KONVOI
WE (2 loops)
WE (2 loops)
WE 3-loops
WE 3-loops
Framatome 3 lo
WE 3-loops
WE 3-loops
VVER V-270
Type
2832
2832
2832
2690
2832
2690
2776
2776
2776
2776
3000
3000
1484
3764
1192
1311
3054
2988
2873
3064
3000
1375
1179
2015
805
805
872
891
872
845
934
934
934
934
1000
1000
657
1350
412
454
1066
1094
1009
1055
1102
408
357
648
Gross
Capacity [MW]
Thermal
The column Non-Electrical Applications indicates the use of the facility to provide: DH district heating.
BRUCE-3
BRUCE-4
BRUCE-5
BRUCE-6
BRUCE-7
BRUCE-8
DARLINGTON-1
DARLINGTON-2
DARLINGTON-3
DARLINGTON-4
DOEL-1
DOEL-2
DOEL-3
DOEL-4
TIHANGE-1
TIHANGE-2
TIHANGE-3
AM -19 ARMENIA-2
BE -2
BE -4
BE -5
BE -7
BE -3
BE -6
BE -8
ARMENIA
ATUCHA-1
EMBALSE
Name
BELGIUM
AR -1
AR -2
Code
ARGENTINA
Country
730
730
817
817
817
782
878
878
878
878
953
953
609
1275
392
433
1006
1047
962
1008
1054
375
335
600
Net
BRUCEPOW
BRUCEPOW
BRUCEPOW
BRUCEPOW
BRUCEPOW
BRUCEPOW
OPG
OPG
OPG
OPG
KOZNPP
KOZNPP
ELETRONU
ELETRONU
ELECTRAB
ELECTRAB
ELECTRAB
ELECTRAB
ELECTRAB
ELECTRAB
ELECTRAB
ANPPJSC
NASA
NASA
Operator
NEI.P
NEI.P
OH/AECL
OH/AECL
OH/AECL
OH/AECL
OH/AECL
OH/AECL
OH/AECL
OH/AECL
AEE
AEE
WH
KWU
ACECOWEN
ACECOWEN
FRAMACEC
ACECOWEN
ACLF
FRAMACEC
ACECOWEN
FAEA
SIEMENS
AECL
NSSS
Supplier
1972-7
1972-9
1978-6
1978-1
1979-5
1979-8
1982-4
1981-9
1984-9
1985-7
1980-7
1982-4
1971-5
1976-1
1969-7
1971-9
1975-1
1978-12
1970-6
1976-4
1978-11
1975-7
1968-6
1974-4
Construction
Start
1977-12
1978-12
1984-12
1984-6
1986-2
1987-3
1990-12
1990-1
1992-12
1993-4
1987-11
1991-8
1982-4
2000-7
1974-8
1975-8
1982-6
1985-4
1975-3
1982-10
1985-6
1980-1
1974-3
1983-4
1978-2
1979-1
1985-3
1984-9
1986-4
1987-5
1992-11
1990-10
1993-2
1993-6
1988-12
1993-12
1985-1
2001-2
1975-2
1975-12
1982-10
1985-7
1975-10
1983-6
1985-9
1980-5
1974-6
1984-1
Grid
Commercial
Connection Operation
78.3
82.4
86.3
82.9
87.7
86.8
86.0
87.6
86.4
89.0
76.7
73.2
70.1
83.5
87.3
89.0
88.0
88.7
89.3
87.7
88.5
66.4
70.4
87.9
EAF %
2000 to
2009
78.7
82.9
86.5
82.9
87.9
86.9
87.2
89.0
87.3
89.8
78.3
76.3
72.1
85.5
88.5
90.0
88.5
88.9
90.9
88.4
90.0
67.4
72.0
87.9
DH
DH
UCF %
Non2000 to electrical
2009
Applics
33
CZ -4
CZ -5
CZ -8
CZ -9
CZ -23
CZ -24
FI -1
FI -2
CZECH REP.
FINLAND
LOVIISA-1
LOVIISA-2
DUKOVANY-1
DUKOVANY-2
DUKOVANY-3
DUKOVANY-4
TEMELIN-1
TEMELIN-2
GUANGDONG-1
GUANGDONG-2
LINGAO 1
LINGAO 2
QINSHAN 1
QINSHAN 2-1
QINSHAN 2-2
QINSHAN 3-1
QINSHAN 3-2
TIANWAN 1
TIANWAN 2
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PHWR
PHWR
PWR
PWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
Type
VVER V-213
VVER V-213
VVER V-213
VVER V-213
VVER V-213
VVER V-213
VVER V-320
VVER V-320
M310
M310
M310
M310
CNP-300
CNP600
CNP600
CANDU 6
CANDU 6
VVER V-428
VVER V-428
CANDU 6
CANDU 500A
CANDU 500A
CANDU 500B
CANDU 500B
CANDU 500B
CANDU 500B
CANDU 6
Model
1500
1500
1375
1375
1444
1375
3000
3000
2905
2905
2895
2895
966
1930
1930
2064
2064
3000
3000
2156
1744
1744
1744
1744
1744
1744
2180
Thermal
510
510
456
456
498
456
1013
1013
984
984
990
990
310
650
650
700
700
1000
1000
675
542
542
540
540
540
540
680
Gross
Capacity [MW]
The column Non-Electrical Applications indicates the use of the facility to provide: DH district heating.
CN -2
CN -3
CN -6
CN -7
CN -1
CN -4
CN -5
CN -8
CN -9
CN -10
CN -11
Name
GENTILLY-2
PICKERING-1
PICKERING-4
PICKERING-5
PICKERING-6
PICKERING-7
PICKERING-8
POINT LEPREAU
Code
Reactor
CA -12
CA -4
CA -7
CA -13
CA -14
CA -15
CA -16
CA -17
CHINA
Country
488
488
427
427
471
427
963
963
944
944
938
938
288
610
610
650
650
933
933
635
515
515
516
516
516
516
635
Net
SKODA
SKODA
SKODA
SKODA
SKODA
SKODA
GEC
GEC
FRAM
FRAM
CNNC
CNNC
CNNC
AECL
AECL
IZ
IZ
BBC
OH/AECL
OH/AECL
OH/AECL
OH/AECL
OH/AECL
OH/AECL
AECL
NSSS
Supplier
FORTUMPH AEE
FORTUMPH AEE
CEZ
CEZ
CEZ
CEZ
CEZ
CEZ
GNPJVC
GNPJVC
LANPC
LANPC
QNPC
NPQJVC
NPQJVC
TQNPC
TQNPC
JNPC
JNPC
HQ
OPG
OPG
OPG
OPG
OPG
OPG
NBEPC
Operator
1977-2
1980-11
1985-2
1986-1
1986-11
1987-6
2000-12
2002-12
1979-1
1979-1
1979-3
1979-3
1987-2
1987-2
1971-5
1972-8
1993-8
1994-2
2002-2
2002-12
1991-12
2002-2
2004-3
2002-11
2003-6
2006-5
2007-5
1982-12
1971-4
1973-5
1982-12
1983-11
1984-11
1986-1
1982-9
1977-5
1981-1
1985-5
1986-3
1986-12
1987-7
2002-6
2003-4
1994-2
1994-5
2002-5
2003-1
1994-4
2002-4
2004-5
2002-12
2003-7
2007-5
2007-8
1983-10
1971-7
1973-6
1983-5
1984-2
1985-1
1986-2
1983-2
Grid
Commercial
Connection Operation
1987-8
1988-4
1997-5
1997-11
1985-3
1996-6
1997-4
1998-6
1998-9
1999-10
2000-10
1974-4
1966-6
1968-5
1974-11
1975-10
1976-3
1976-9
1975-5
Construction
Start
90.5
91.0
88.0
87.5
86.6
87.1
66.6
75.2
90.0
87.3
87.5
88.0
86.8
77.3
87.6
87.2
89.9
74.8
83.7
79.3
69.5
61.2
70.1
73.4
70.3
75.8
67.0
EAF %
2000 to
2009
91.3
92.2
88.5
88.0
87.3
87.9
66.6
75.6
90.4
87.6
87.9
88.1
87.3
77.3
87.6
87.7
90.0
74.8
83.7
80.3
69.6
61.9
70.8
73.9
70.6
76.8
69.2
DH
DH
UCF %
Non2000 to electrical
2009
Applics
34
FRANCE
Country
BELLEVILLE-1
BELLEVILLE-2
BLAYAIS-1
BLAYAIS-2
BLAYAIS-3
BLAYAIS-4
BUGEY-2
BUGEY-3
BUGEY-4
BUGEY-5
CATTENOM-1
CATTENOM-2
CATTENOM-3
CATTENOM-4
CHINON-B-1
CHINON-B-2
CHINON-B-3
CHINON-B-4
CHOOZ-B-1
CHOOZ-B-2
CIVAUX-1
CIVAUX-2
CRUAS-1
CRUAS-2
CRUAS-3
CRUAS-4
DAMPIERRE-1
OLKILUOTO-1
OLKILUOTO-2
FI -3
FI -4
FR -54
FR -55
FR -32
FR -33
FR -34
FR -35
FR -13
FR -14
FR -15
FR -16
FR -50
FR -53
FR -60
FR -65
FR -40
FR -41
FR -56
FR -57
FR -62
FR -70
FR -72
FR -73
FR -42
FR -43
FR -44
FR -45
FR -22
Name
Code
Reactor
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
BWR
BWR
Type
BWR 2500
BWR 2500
Model
3817
3817
2785
2785
2785
2785
2785
2785
2785
2785
3817
3817
3817
3817
2785
2785
2785
2785
4270
4270
4270
4270
2785
2785
2785
2785
2785
2500
2500
Thermal
1363
1363
951
951
951
951
945
945
917
917
1362
1362
1362
1362
954
954
954
954
1560
1560
1561
1561
956
956
956
956
937
890
890
Gross
Capacity [MW]
1310
1310
910
910
910
910
910
910
880
880
1300
1300
1300
1300
905
905
905
905
1500
1500
1495
1495
915
915
915
915
890
860
860
Net
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
TVO
TVO
Operator
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
ASEASTAL
ASEASTAL
NSSS
Supplier
1980-5
1980-8
1977-1
1977-1
1978-4
1978-4
1972-11
1973-9
1974-6
1974-7
1979-10
1980-7
1982-6
1983-9
1977-3
1977-3
1980-10
1981-2
1984-1
1985-12
1988-10
1991-4
1978-8
1978-11
1979-4
1979-10
1975-2
1974-2
1975-11
Construction
Start
1987-10
1988-7
1981-6
1982-7
1983-8
1983-5
1978-5
1978-9
1979-3
1979-7
1986-11
1987-9
1990-7
1991-5
1982-11
1983-11
1986-10
1987-11
1996-8
1997-4
1997-12
1999-12
1983-4
1984-9
1984-5
1984-10
1980-3
1978-9
1980-2
1988-6
1989-1
1981-12
1983-2
1983-11
1983-10
1979-3
1979-3
1979-7
1980-1
1987-4
1988-2
1991-2
1992-1
1984-2
1984-8
1987-3
1988-4
2000-5
2000-9
2002-1
2002-4
1984-4
1985-4
1984-9
1985-2
1980-9
1979-10
1982-7
Grid
Commercial
Connection Operation
78.2
83.6
72.8
78.2
80.6
77.8
79.9
74.2
78.1
82.1
82.0
82.5
78.8
86.1
77.2
77.9
78.2
78.0
80.2
80.1
77.9
82.7
75.8
77.9
76.1
76.1
80.3
95.5
95.2
EAF %
2000 to
2009
79.3
85.0
76.7
81.0
84.0
80.2
81.7
77.2
79.5
84.4
84.0
84.6
80.1
87.5
78.6
79.4
79.6
79.1
82.1
82.9
79.1
84.3
77.1
79.7
77.7
77.6
81.7
96.0
95.7
UCF %
Non2000 to electrical
2009
Applics
35
Country
Name
DAMPIERRE-2
DAMPIERRE-3
DAMPIERRE-4
FESSENHEIM-1
FESSENHEIM-2
FLAMANVILLE-1
FLAMANVILLE-2
GOLFECH-1
GOLFECH-2
GRAVELINES-1
GRAVELINES-2
GRAVELINES-3
GRAVELINES-4
GRAVELINES-5
GRAVELINES-6
NOGENT-1
NOGENT-2
PALUEL-1
PALUEL-2
PALUEL-3
PALUEL-4
PENLY-1
PENLY-2
PHENIX
ST. ALBAN-1
ST. ALBAN-2
ST. LAURENT-B-1
ST. LAURENT-B-2
TRICASTIN-1
TRICASTIN-2
Code
FR -29
FR -30
FR -31
FR -11
FR -12
FR -46
FR -47
FR -61
FR -68
FR -20
FR -21
FR -27
FR -28
FR -51
FR -52
FR -58
FR -59
FR -36
FR -37
FR -38
FR -39
FR -63
FR -64
FR -10
FR -48
FR -49
FR -17
FR -23
FR -18
FR -19
Reactor
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
FBR
PWR
PWR
PWR
PWR
PWR
PWR
Type
CP1
CP1
CP1
CP0
CP0
P4 REP 1300
P4 REP 1300
P'4 REP 1300
P'4 REP 1300
CP1
CP1
CP1
CP1
CP1
CP1
P'4 REP 1300
P'4 REP 1300
P4 REP 1300
P4 REP 1300
P4 REP 1300
P4 REP 1300
P'4 REP 1300
P'4 REP 1300
PH-250
P4 REP 1300
P4 REP 1300
CP2
CP2
CP1
CP1
Model
2785
2785
2785
2660
2660
3817
3817
3817
3817
2785
2785
2785
2785
2785
2785
3817
3817
3817
3817
3817
3817
3817
3817
345
3817
3817
2785
2785
2785
2785
Thermal
937
937
937
920
920
1382
1382
1363
1363
951
951
951
951
951
951
1363
1363
1382
1382
1382
1382
1382
1382
142
1381
1381
956
956
955
955
Gross
Capacity [MW]
890
890
890
880
880
1330
1330
1310
1310
910
910
910
910
910
910
1310
1310
1330
1330
1330
1330
1330
1330
130
1335
1335
915
915
915
915
Net
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
EDF
CEA/EDF
EDF
EDF
EDF
EDF
EDF
EDF
Operator
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
CNCLNEY
FRAM
FRAM
FRAM
FRAM
FRAM
FRAM
NSSS
Supplier
1975-4
1975-9
1975-12
1971-9
1972-2
1979-12
1980-5
1982-11
1984-10
1975-2
1975-3
1975-12
1976-4
1979-10
1979-10
1981-5
1982-1
1977-8
1978-1
1979-2
1980-2
1982-9
1984-8
1968-11
1979-1
1979-7
1976-5
1976-7
1974-11
1974-12
Construction
Start
1980-12
1981-1
1981-8
1977-4
1977-10
1985-12
1986-7
1990-6
1993-6
1980-3
1980-8
1980-12
1981-6
1984-8
1985-8
1987-10
1988-12
1984-6
1984-9
1985-9
1986-4
1990-5
1992-2
1973-12
1985-8
1986-7
1981-1
1981-6
1980-5
1980-8
1981-2
1981-5
1981-11
1978-1
1978-4
1986-12
1987-3
1991-2
1994-3
1980-11
1980-12
1981-6
1981-10
1985-1
1985-10
1988-2
1989-5
1985-12
1985-12
1986-2
1986-6
1990-12
1992-11
1974-7
1986-5
1987-3
1983-8
1983-8
1980-12
1980-12
Grid
Commercial
Connection Operation
79.6
77.9
76.4
71.4
70.2
75.2
81.2
85.1
84.3
81.8
82.0
79.9
79.4
81.6
82.2
82.2
80.5
79.6
77.8
72.5
80.4
84.1
84.6
31.7
75.7
78.7
80.2
78.0
80.9
78.1
EAF %
2000 to
2009
81.3
79.5
78.3
72.4
71.4
76.6
82.5
86.8
86.4
83.3
83.7
81.7
81.3
83.4
83.3
83.6
81.8
81.0
79.1
74.1
82.9
84.8
85.5
31.9
77.2
81.4
82.2
79.5
84.6
80.6
UCF %
Non2000 to electrical
2009
Applics
36
HU -1
HU -2
HU -3
HU -4
IN -13
IN -14
IN -15
IN -9
HUNGARY
INDIA
KAIGA-1
KAIGA-2
KAIGA-3
KAKRAPAR-1
PAKS-1
PAKS-2
PAKS-3
PAKS-4
BIBLIS-A (KWB A)
BIBLIS-B (KWB B)
BROKDORF (KBR)
BRUNSBUETTEL (KKB)
EMSLAND (KKE)
GRAFENRHEINFELD (KKG)
GROHNDE (KWG)
GUNDREMMINGEN-B (GUN-B)
GUNDREMMINGEN-C (GUN-C)
ISAR-1 (KKI 1)
ISAR-2 (KKI 2)
KRUEMMEL (KKK)
NECKARWESTHEIM-1 (GKN 1)
NECKARWESTHEIM-2 (GKN 2)
PHILIPPSBURG-1 (KKP 1)
PHILIPPSBURG-2 (KKP 2)
UNTERWESER (KKU)
PHWR
PHWR
PHWR
PHWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
BWR
PWR
PWR
PWR
BWR
BWR
BWR
PWR
BWR
PWR
PWR
BWR
PWR
PWR
PWR
PWR
Type
Horizontal Pre
Horizontal Pre
Horizontal Pre
Horizontal Pre
VVER V-213
VVER V-213
VVER V-213
VVER V-213
PWR
PWR
PWR
BWR '69
Konvoi
PWR
PWR
BWR 72
BWR 72
BWR '69
Konvoi
BWR 69
PWR
Konvoi
BWR '69
PWR
PWR
CP1
CP1
Model
801
801
800
801
1485
1485
1485
1485
3517
3733
3900
2292
3850
3765
3900
3840
3840
2575
3950
3690
2497
3850
2575
3950
3900
2785
2785
220
220
220
220
500
500
500
500
1225
1300
1480
806
1400
1345
1430
1344
1344
912
1485
1402
840
1400
926
1458
1410
955
955
Gross
Capacity [MW]
Thermal
The column Non-Electrical Applications indicates the use of the facility to provide: DH district heating.
DE -12
DE -18
DE -32
DE -13
DE -33
DE -23
DE -27
DE -26
DE -28
DE -16
DE -31
DE -20
DE -15
DE -44
DE -14
DE -24
DE -17
TRICASTIN-3
TRICASTIN-4
FR -25
FR -26
Reactor
Name
Code
GERMANY
Country
202
202
202
202
470
473
473
473
1167
1240
1410
771
1329
1275
1360
1284
1288
878
1410
1346
785
1310
890
1392
1345
915
915
Net
NPCIL
NPCIL
NPCIL
NPCIL
PAKS Zrt
PAKS Zrt
PAKS Zrt
PAKS Zrt
RWE
RWE
E.ON
KKB
KLE
E.ON
KWG
KGG
KGG
E.ON
E.ON
KKK
EnKK
EnKK
EnKK
EnKK
E.ON
EDF
EDF
Operator
NPCIL
NPCIL
NPCIL
NPCIL
AEE
AEE
AEE
AEE
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
KWU
FRAM
FRAM
NSSS
Supplier
1989-9
1989-12
2002-3
1984-12
1974-8
1974-8
1979-10
1979-10
1970-1
1972-2
1976-1
1970-4
1982-8
1975-1
1976-6
1976-7
1976-7
1972-5
1982-9
1974-4
1972-2
1982-11
1970-10
1977-7
1972-7
1975-4
1975-5
Construction
Start
2000-10
1999-12
2007-4
1992-11
1982-12
1984-9
1986-9
1987-8
1974-8
1976-4
1986-10
1976-7
1988-4
1981-12
1984-9
1984-3
1984-11
1977-12
1988-1
1983-9
1976-6
1989-1
1979-5
1984-12
1978-9
1981-2
1981-6
2000-11
2000-3
2007-5
1993-5
1983-8
1984-11
1986-12
1987-11
1975-2
1977-1
1986-12
1977-2
1988-6
1982-6
1985-2
1984-7
1985-1
1979-3
1988-4
1984-3
1976-12
1989-4
1980-3
1985-4
1979-9
1981-5
1981-11
Grid
Commercial
Connection Operation
69.6
70.9
30.9
65.3
87.3
70.1
86.2
88.7
59.0
67.7
94.3
55.9
94.8
91.3
93.6
91.2
88.8
90.2
94.6
63.1
90.0
93.7
86.8
89.5
82.0
79.3
79.5
EAF %
2000 to
2009
89.3
90.2
61.0
76.2
87.4
70.1
87.0
88.8
59.6
68.8
94.5
56.8
95.0
91.5
94.0
91.5
89.5
91.4
94.8
63.4
90.3
94.0
87.4
92.3
84.1
82.0
81.5
DH
DH
DH
UCF %
Non2000 to electrical
2009
Applics
37
JP -5
JP -9
JP -10
JP -16
JP -17
JP -18
JP -25
JP -26
JP -35
JP -38
JP -12
JP -27
JP -45
JP -46
JP -36
FUKUSHIMA-DAIICHI-1
FUKUSHIMA-DAIICHI-2
FUKUSHIMA-DAIICHI-3
FUKUSHIMA-DAIICHI-4
FUKUSHIMA-DAIICHI-5
FUKUSHIMA-DAIICHI-6
FUKUSHIMA-DAINI-1
FUKUSHIMA-DAINI-2
FUKUSHIMA-DAINI-3
FUKUSHIMA-DAINI-4
GENKAI-1
GENKAI-2
GENKAI-3
GENKAI-4
HAMAOKA-3
Name
KAKRAPAR-2
MADRAS-1
MADRAS-2
NARORA-1
NARORA-2
RAJASTHAN-1
RAJASTHAN-2
RAJASTHAN-3
RAJASTHAN-4
RAJASTHAN-5
TARAPUR-1
TARAPUR-2
TARAPUR-3
TARAPUR-4
Code
IN -10
IN -5
IN -6
IN -7
IN -8
IN -3
IN -4
IN -11
IN -12
IN -19
IN -1
IN -2
IN -23
IN -24
Reactor
BWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
PWR
PWR
PWR
PWR
BWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
PHWR
BWR
BWR
PHWR
PHWR
Type
BWR-3
BWR-4
BWR-4
BWR-4
BWR-4
BWR-5
BWR-5
BWR-5
BWR-5
BWR-5
M (2-loop)
M (2-loop)
M (4-loop)
M (4-loop)
BWR-5
Horizontal Pre
Horizontal Pre
Horizontal Pre
Horizontal Pre
Horizontal Pre
Horizontal Pre
Horizontal Pre
Horizontal Pre
Horizontal Pre
Horizontal Pre
BWR-1, Mark 2
BWR-1, Mark 2
Horizontal Pre
Horizontal Pre
Model
1380
2381
2381
2381
2381
3293
3293
3293
3293
3293
1650
1650
3423
3423
3293
801
801
801
801
801
693
693
801
801
801
530
530
1730
1730
Thermal
460
784
784
784
784
1100
1100
1100
1100
1100
559
559
1180
1180
1100
220
220
220
220
220
100
200
220
220
220
160
160
540
540
Gross
Capacity [MW]
439
760
760
760
760
1067
1067
1067
1067
1067
529
529
1127
1127
1056
202
205
205
202
202
90
187
202
202
202
150
150
490
490
Net
The column Non-Electrical Applications indicates the use of the facility to provide: DS desalination, PH process heating.
JAPAN
Country
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
KYUSHU
KYUSHU
KYUSHU
KYUSHU
CHUBU
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
Operator
GE/GETSC
GE/T
TOSHIBA
HITACHI
TOSHIBA
GE/T
TOSHIBA
HITACHI
TOSHIBA
HITACHI
MHI
MHI
MHI
MHI
TOSHIBA
NPCIL
NPCIL
NPCIL
NPCIL
NPCIL
AECL
AECL/DAE
NPCIL
NPCIL
NPCIL
GE
GE
NPCIL
NPCIL
NSSS
Supplier
1967-7
1969-6
1970-12
1973-2
1972-5
1973-10
1976-3
1979-5
1981-3
1981-5
1971-9
1977-2
1988-6
1992-7
1983-4
1985-4
1971-1
1972-10
1976-12
1977-11
1965-8
1968-4
1990-2
1990-10
2002-9
1964-10
1964-10
2000-5
2000-3
Construction
Start
1970-11
1973-12
1974-10
1978-2
1977-9
1979-5
1981-7
1983-6
1984-12
1986-12
1975-2
1980-6
1993-6
1996-11
1987-1
1995-3
1983-7
1985-9
1989-7
1992-1
1972-11
1980-11
2000-3
2000-11
2009-12
1969-4
1969-5
2006-6
2005-6
1971-3
1974-7
1976-3
1978-10
1978-4
1979-10
1982-4
1984-2
1985-6
1987-8
1975-10
1981-3
1994-3
1997-7
1987-8
1995-9
1984-1
1986-3
1991-1
1992-7
1973-12
1981-4
2000-6
2000-12
2010-2
1969-10
1969-10
2006-8
2005-9
Grid
Commercial
Connection Operation
47.6
67.4
69.0
62.2
67.4
67.3
75.0
65.1
59.8
58.6
80.9
76.3
84.8
84.6
71.5
85.6
87.3
88.7
82.5
84.6
86.5
57.1
52.1
47.6
67.4
69.0
61.8
67.3
67.1
75.0
65.1
59.8
58.6
80.9
76.3
84.8
84.6
71.3
91.4
60.1
78.6
67.6
67.6
15.6
67.0
89.1
90.7
DS
DS
-
DS
DS
PH
PH
PH
PH
-
UCF %
Non2000 to electrical
2009
Applics
74.8
45.8
59.8
54.0
57.2
15.4
64.2
72.2
72.0
EAF %
2000 to
2009
38
HAMAOKA-4
HAMAOKA-5
HIGASHI DORI 1 (TOHOKU)
IKATA-1
IKATA-2
IKATA-3
KASHIWAZAKI KARIWA-1
KASHIWAZAKI KARIWA-2
KASHIWAZAKI KARIWA-3
KASHIWAZAKI KARIWA-4
KASHIWAZAKI KARIWA-5
KASHIWAZAKI KARIWA-6
KASHIWAZAKI KARIWA-7
MIHAMA-1
MIHAMA-2
MIHAMA-3
OHI-1
OHI-2
OHI-3
OHI-4
ONAGAWA-1
ONAGAWA-2
ONAGAWA-3
SENDAI-1
SENDAI-2
SHIKA-1
SHIKA-2
SHIMANE-1
SHIMANE-2
TAKAHAMA-1
JP -49
JP -60
JP -58
JP -23
JP -32
JP -47
JP -33
JP -39
JP -52
JP -53
JP -40
JP -55
JP -56
JP -4
JP -6
JP -14
JP -15
JP -19
JP -50
JP -51
JP -22
JP -54
JP -57
JP -28
JP -37
JP -48
JP -59
JP -7
JP -41
JP -8
Reactor
Name
Code
BWR
BWR
BWR
PWR
PWR
PWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
BWR
BWR
BWR
PWR
PWR
BWR
BWR
BWR
BWR
PWR
Type
BWR-5
ABWR
BWR-5
M (2-loop)
M (2-loop)
M (3-loop)
BWR-5
BWR-5
BWR-5
BWR-5
BWR-5
ABWR
ABWR
W (2-loop)
M (2-loop)
M (3-loop)
W (4-loop)
W (4-loop)
M (4-loop)
M (4-loop)
BWR-4
BWR-5
BWR-5
M (3-loop)
M (3-loop)
BWR 5
ABWR
BWR-3
BWR-5
M (3-loop)
Model
3293
3926
3293
1650
1650
2660
3293
3293
3293
3293
3293
3926
3926
1031
1456
2440
3423
3423
3423
3423
1593
2436
2436
2660
2660
1593
3926
1380
2436
2440
1137
1267
1100
566
566
890
1100
1100
1100
1100
1100
1356
1356
340
500
826
1175
1175
1180
1180
524
825
825
890
890
540
1206
460
820
826
Gross
Capacity [MW]
Thermal
The column Non-Electrical Applications indicates the use of the facility to provide: DS desalination.
Country
1092
1212
1067
538
538
846
1067
1067
1067
1067
1067
1315
1315
320
470
780
1120
1120
1127
1127
498
796
796
846
846
505
1108
439
789
780
Net
CHUBU
CHUBU
TOHOKU
SHIKOKU
SHIKOKU
SHIKOKU
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
TEPCO
KEPCO
KEPCO
KEPCO
KEPCO
KEPCO
KEPCO
KEPCO
TOHOKU
TOHOKU
TOHOKU
KYUSHU
KYUSHU
HOKURIKU
HOKURIKU
CHUGOKU
CHUGOKU
KEPCO
Operator
TOSHIBA
TOSHIBA
TOSHIBA
MHI
MHI
MHI
TOSHIBA
TOSHIBA
TOSHIBA
HITACHI
HITACHI
TOSHIBA
HITACHI
WH
MHI
MHI
WH
WH
MHI
MHI
TOSHIBA
TOSHIBA
TOSHIBA
MHI
MHI
HITACHI
HITACHI
HITACHI
HITACHI
WH/MHI
NSSS
Supplier
1989-10
2000-7
2000-11
1973-9
1978-8
1990-10
1980-6
1985-11
1989-3
1990-3
1985-6
1992-11
1993-7
1967-2
1968-5
1972-8
1972-10
1972-12
1987-10
1988-6
1980-7
1991-4
1998-1
1979-12
1981-10
1989-7
2001-8
1970-7
1985-2
1970-4
Construction
Start
1993-1
2004-4
2005-3
1977-2
1981-8
1994-3
1985-2
1990-2
1992-12
1993-12
1989-9
1996-1
1996-12
1970-8
1972-4
1976-2
1977-12
1978-10
1991-6
1992-6
1983-11
1994-12
2001-5
1983-9
1985-4
1993-1
2005-7
1973-12
1988-7
1974-3
1993-9
2005-1
2005-12
1977-9
1982-3
1994-12
1985-9
1990-9
1993-8
1994-8
1990-4
1996-11
1997-7
1970-11
1972-7
1976-12
1979-3
1979-12
1991-12
1993-2
1984-6
1995-7
2002-1
1984-7
1985-11
1993-7
2006-3
1974-3
1989-2
1974-11
Grid
Commercial
Connection Operation
75.6
54.7
77.3
77.7
78.7
87.0
42.8
47.1
48.9
50.1
50.8
63.4
63.2
69.9
73.4
64.0
78.7
79.1
75.4
87.3
51.8
67.5
65.6
84.5
86.2
63.6
36.1
70.6
78.9
83.9
EAF %
2000 to
2009
76.7
62.3
77.4
77.8
78.8
87.0
45.7
47.1
50.7
54.8
55.9
67.6
66.9
70.0
73.4
64.0
78.8
79.1
75.4
87.3
56.1
71.6
67.2
84.5
86.2
63.6
36.1
70.6
78.9
83.9
DS
DS
DS
DS
DS
-
UCF %
Non2000 to electrical
2009
Applics
39
KR -1
KR -2
KR -5
KR -6
KR -9
KR -10
KR -13
KR -14
KR -19
KR -20
KR -3
KR -4
KR -15
KR -16
KR -7
KR -8
KR -11
KR -12
KR -17
KR -18
KORI-1
KORI-2
KORI-3
KORI-4
ULCHIN-1
ULCHIN-2
ULCHIN-3
ULCHIN-4
ULCHIN-5
ULCHIN-6
WOLSONG-1
WOLSONG-2
WOLSONG-3
WOLSONG-4
YONGGWANG-1
YONGGWANG-2
YONGGWANG-3
YONGGWANG-4
YONGGWANG-5
YONGGWANG-6
Name
TAKAHAMA-2
TAKAHAMA-3
TAKAHAMA-4
TOKAI-2
TOMARI-1
TOMARI-2
TOMARI-3
TSURUGA-1
TSURUGA-2
Code
JP -13
JP -29
JP -30
JP -21
JP -43
JP -44
JP -64
JP -3
JP -34
Reactor
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PHWR
PHWR
PHWR
PHWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
BWR
PWR
PWR
PWR
BWR
PWR
Type
WH △60
WH F
WH F
WH F
France CPI
France CPI
OPR-1000
OPR-1000
OPR-1000
OPR-1000
CANDU 6
CANDU 6
CANDU 6
CANDU 6
WH F
WH F
OPR-1000
OPR-1000
OPR-1000
OPR-1000
M (3-loop)
M (3-loop)
M (3-loop)
BWR-5
M (2-loop)
M (2-loop)
M (3-loop)
BWR-2
M (4-loop)
Model
1729
1882
2912
2912
2785
2775
2825
2825
2815
2825
2061
2061
2061
2061
2787
2787
2825
2825
2825
2825
2440
2660
2660
3293
1650
1650
2660
1070
3411
Thermal
603
675
1035
1035
985
984
1047
1045
1048
1048
622
730
729
730
985
978
1039
1039
1046
1050
826
870
870
1100
579
579
912
357
1160
Gross
Capacity [MW]
The column Non-Electrical Applications indicates the use of the facility to provide: DS desalination.
KOREA REP.
Country
576
637
1007
1007
945
942
994
998
1001
1001
597
710
707
708
953
947
997
994
988
996
780
830
830
1060
550
550
866
340
1110
Net
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KHNP
KEPCO
KEPCO
KEPCO
JAPCO
HEPCO
HEPCO
HEPCO
JAPCO
JAPCO
Operator
WH
WH
WH
WH
FRAM
FRAM
DHICKOPC
DHICKOPC
DHICKOPC
DHICKOPC
AECL
AECL/DHI
AECL/DHI
AECL/DHI
WH
WH
DHICKAEC
DHICKAEC
DHICKOPC
DHICKOPC
MHI
MHI
MHI
GE
MHI
MHI
MHI
GE
MHI
NSSS
Supplier
1972-4
1977-12
1979-10
1980-4
1983-1
1983-7
1993-7
1993-11
1999-10
2000-9
1977-10
1992-6
1994-3
1994-7
1981-6
1981-12
1989-12
1990-5
1997-6
1997-11
1971-3
1980-12
1981-3
1973-10
1985-4
1985-6
2004-11
1966-11
1982-11
Construction
Start
1977-6
1983-4
1985-1
1985-12
1988-4
1989-4
1998-1
1998-12
2003-12
2005-1
1982-12
1997-4
1998-3
1999-5
1986-3
1986-11
1994-10
1995-7
2001-12
2002-9
1975-1
1984-5
1984-11
1978-3
1988-12
1990-8
2009-3
1969-11
1986-6
1978-4
1983-7
1985-9
1986-4
1988-9
1989-9
1998-8
1999-12
2004-7
2005-4
1983-4
1997-7
1998-7
1999-10
1986-8
1987-6
1995-3
1996-1
2002-5
2002-12
1975-11
1985-1
1985-6
1978-11
1989-6
1991-4
2009-12
1970-3
1987-2
Grid
Commercial
Connection Operation
91.1
90.4
91.4
91.9
88.9
88.3
91.7
90.9
91.9
93.5
81.2
92.5
93.7
93.5
90.7
91.4
92.4
90.3
86.6
88.8
63.9
74.7
63.8
74.3
90.8
90.3
91.3
91.7
88.7
88.1
91.6
90.8
91.9
93.3
80.4
92.4
93.7
93.5
90.6
91.3
92.3
90.2
86.6
88.6
80.1
77.6
84.5
73.5
85.8
81.1
DS
DS
-
UCF %
Non2000 to electrical
2009
Applics
80.1
77.6
84.5
73.2
85.8
81.1
EAF %
2000 to
2009
40
Reactor
CHASNUPP 1
KANUPP
RO -1
RO -2
RU -96
RU -97
RU -98
RU -99
RU -21
RU -141
RU -142
RU -143
RU -144
RU -30
RU -31
RU -36
RU -12
RU -13
RU -32
RU -33
RU -17
RU -22
RU -38
ROMANIA
RUSSIA
2 loops PWR
BWR-5
BWR-5
Model
PWR
PWR
PWR
PWR
FBR
LWGR
LWGR
LWGR
LWGR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
LWGR
LWGR
LWGR
VVER V-320
VVER V-320
VVER V-320
VVER V-320
BN-600
EGP-6
EGP-6
EGP-6
EGP-6
VVER V-338
VVER V-338
VVER V-338
VVER V-230
VVER V-230
VVER V-213
VVER V-213
RBMK-1000
RBMK-1000
RBMK-1000
PHWR CANDU 6
PHWR CANDU 6
PWR CNP-300
PHWR CANDU-137 MW
PWR
BWR
BWR
Type
3000
3000
3000
3200
1470
62
62
62
62
3000
3000
3200
1375
1375
1375
1375
3200
3200
3200
2180
2180
999
433
1366
2027
2027
1000
1000
1000
1000
600
12
12
12
12
1000
1000
1000
440
440
440
440
1000
1000
1000
706
706
325
137
515
682
682
Gross
Capacity [MW]
Thermal
950
950
950
950
560
11
11
11
11
950
950
950
411
411
411
411
925
925
925
650
650
300
125
487
650
650
Net
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
SNN
SNN
PAEC
PAEC
EPZ
CFE
CFE
Operator
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
AECL
AECL
CNNC
CGE
S/KWU
GE
GE
NSSS
Supplier
The column Non-Electrical Applications indicates the use of the facility to provide: DS desalination, DH district heating, PH process heating.
BALAKOVO-1
BALAKOVO-2
BALAKOVO-3
BALAKOVO-4
BELOYARSKY-3 (BN-600)
BILIBINO-1
BILIBINO-2
BILIBINO-3
BILIBINO-4
KALININ-1
KALININ-2
KALININ-3
KOLA-1
KOLA-2
KOLA-3
KOLA-4
KURSK-1
KURSK-2
KURSK-3
CERNAVODA-1
CERNAVODA-2
BORSSELE
PK -2
PK -1
LAGUNA VERDE-1
LAGUNA VERDE-2
Name
PAKISTAN
MX -1
MX -2
Code
NETHERLANDS NL -2
MEXICO
Country
1980-12
1981-8
1982-11
1984-4
1969-1
1970-1
1970-1
1970-1
1970-1
1977-2
1982-2
1985-10
1970-5
1970-5
1977-4
1976-8
1972-6
1973-1
1978-4
1982-7
1983-7
1993-8
1966-8
1969-7
1976-10
1977-6
Construction
Start
1985-12
1987-10
1988-12
1993-4
1980-4
1974-1
1974-12
1975-12
1976-12
1984-5
1986-12
2004-12
1973-6
1974-12
1981-3
1984-10
1976-12
1979-1
1983-10
1996-7
2007-8
2000-6
1971-10
1973-7
1989-4
1994-11
1986-5
1988-1
1989-4
1993-12
1981-11
1974-4
1975-2
1976-2
1977-1
1985-6
1987-3
2005-11
1973-12
1975-2
1982-12
1984-12
1977-10
1979-8
1984-3
1996-12
2007-10
2000-9
1972-12
1973-10
1990-7
1995-4
Grid
Commercial
Connection Operation
85.6
80.6
82.3
83.1
77.2
45.2
50.8
53.0
50.4
81.4
82.0
83.7
65.0
65.7
70.1
70.9
65.4
62.9
68.8
89.0
93.7
70.8
34.0
93.0
84.1
84.6
EAF %
2000 to
2009
87.1
84.5
85.4
85.9
78.1
70.8
80.3
82.1
79.6
82.4
83.6
84.0
83.3
81.7
86.5
86.4
68.2
64.0
70.2
90.2
94.8
71.4
35.1
93.3
84.6
85.1
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH
DH
DH
DH
DH, PH
DH, PH
PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH
DH
DS
UCF %
Non2000 to electrical
2009
Applics
41
ALMARAZ-1
ALMARAZ-2
ASCO-1
ASCO-2
COFRENTES
SANTA MARIA DE GARONA
TRILLO-1
PWR
PWR
PWR
PWR
BWR
BWR
PWR
WE 3-loops
WE 3-loops
WE 3-loops
WE 3-loops
BWR-6
BWR-3
PWR 3 loops
CP1
CP1
Westinghouse 2
VVER V-213
VVER V-213
VVER V-213
VVER V-213
RBMK-1000
RBMK-1000
RBMK-1000
RBMK-1000
RBMK-1000
VVER V-179
VVER V-179
VVER V-187
RBMK-1000
RBMK-1000
RBMK-1000
VVER V-320I
Model
2947
2729
2941
2941
3237
1381
3010
2775
2775
1994
1430
1444
1471
1471
3200
3200
3200
3200
3200
1375
1375
3000
3200
3200
3200
3200
Thermal
1050
980
1033
1027
1092
466
1066
940
940
730
475
481
470
470
1000
1000
1000
1000
1000
417
417
1000
1000
1000
1000
1000
Gross
Capacity [MW]
944
956
995
997
1064
446
1003
900
900
666
442
448
436
436
925
925
925
925
925
385
385
950
925
925
925
950
Net
The column Non-Electrical Applications indicates the use of the facility to provide: DH district heating, PH process heating.
ES -6
ES -7
ES -8
ES -9
ES -10
ES -2
ES -11
SPAIN
PWR
PWR
PWR
KRSKO
KOEBERG-1
KOEBERG-2
SI -1
SLOVENIA
PWR
PWR
PWR
PWR
LWGR
LWGR
LWGR
LWGR
LWGR
PWR
PWR
PWR
LWGR
LWGR
LWGR
PWR
Type
BOHUNICE-3
BOHUNICE-4
MOCHOVCE-1
MOCHOVCE-2
SOUTH AFRICA ZA -1
ZA -2
SK -13
SK -14
SK -6
SK -7
Name
KURSK-4
LENINGRAD-1
LENINGRAD-2
LENINGRAD-3
LENINGRAD-4
NOVOVORONEZH-3
NOVOVORONEZH-4
NOVOVORONEZH-5
SMOLENSK-1
SMOLENSK-2
SMOLENSK-3
VOLGODONSK-1
Code
Reactor
RU -39
RU -15
RU -16
RU -34
RU -35
RU -9
RU -11
RU -20
RU -23
RU -24
RU -67
RU -59
SLOVAKIA
Country
CNAT
CNAT
ANAV
ANAV
ID
NUCLENOR
CNAT
ESKOM
ESKOM
NEK
SE,plc
SE,plc
SE,plc
SE,plc
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
REA
Operator
WH
WH
WH
WH
GE
GE
KWU
FRAM
FRAM
WH
SKODA
SKODA
SKODA
SKODA
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
ROSATOM
NSSS
Supplier
1973-7
1973-7
1974-5
1975-3
1975-9
1966-9
1979-8
1976-7
1976-7
1975-3
1976-12
1976-12
1983-10
1983-10
1981-5
1970-3
1970-6
1973-12
1975-2
1967-7
1967-7
1974-3
1975-10
1976-6
1984-5
1981-9
Construction
Start
1981-5
1983-10
1983-8
1985-10
1984-10
1971-3
1988-5
1984-4
1985-7
1981-10
1984-8
1985-8
1998-7
1999-12
1985-12
1973-12
1975-7
1979-12
1981-2
1971-12
1972-12
1980-5
1982-12
1985-5
1990-1
2001-3
1983-9
1984-7
1984-12
1986-3
1985-3
1971-5
1988-8
1984-7
1985-11
1983-1
1985-2
1985-12
1998-10
2000-4
1986-2
1974-11
1976-2
1980-6
1981-8
1972-6
1973-3
1981-2
1983-9
1985-7
1990-10
2001-12
Grid
Commercial
Connection Operation
91.7
90.2
86.2
88.9
85.0
92.9
90.2
78.0
77.2
90.3
79.5
79.7
83.4
83.8
72.3
77.7
75.8
68.9
61.4
64.5
76.0
70.3
73.2
72.8
81.0
85.9
EAF %
2000 to
2009
92.8
91.3
87.1
89.9
86.2
93.4
90.3
79.9
81.4
91.5
83.3
83.1
85.8
85.6
73.5
79.1
77.5
70.8
63.3
65.7
77.9
71.4
74.6
74.4
81.8
86.4
DH, PH
DH, PH
-
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
DH, PH
-
UCF %
Non2000 to electrical
2009
Applics
42
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
DUNGENESS-B1
DUNGENESS-B2
HARTLEPOOL-A1
HARTLEPOOL-A2
HEYSHAM-A1
HEYSHAM-A2
HEYSHAM-B1
HEYSHAM-B2
HINKLEY POINT-B1
HINKLEY POINT-B2
HUNTERSTON-B1
UK
AGR
AGR
AGR
AGR
AGR
AGR
AGR
AGR
AGR
AGR
AGR
WH - 2 loops
WH - 2 loops
PWR 3 Loop
BWR 6
BWR 4
WE (3 loops)
W 3-loop
BWR 75
BWR 75
BWR 3000
ABB BWR
ABB BWR
BWR 75
WE 3-loops
Model
1500
1500
1500
1500
1500
1500
1550
1550
1494
1494
1496
1130
1130
3002
3600
1097
2928
2928
3300
1375
1800
3900
2540
2660
3135
2775
2941
615
615
655
655
625
625
680
680
655
655
644
380
380
1035
1220
390
1033
1028
1212
487
661
1450
887
917
1105
981
1087
Gross
Capacity [MW]
Thermal
520
520
595
595
585
575
620
620
410
430
430
365
365
970
1165
373
978
990
1170
473
624
1152
856
813
1044
936
1045
Net
The column Non-Electrical Applications indicates the use of the facility to provide: DH district heating, PH process heating.
GB -18A
GB -18B
GB -19A
GB -19B
GB -20A
GB -20B
GB -22A
GB -22B
GB -16A
GB -16B
GB -17A
PWR
PWR
PWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
BWR
PWR
PWR
PWR
PWR
Type
BEZNAU-1
BEZNAU-2
GOESGEN
LEIBSTADT
MUEHLEBERG
FORSMARK-1
FORSMARK-2
FORSMARK-3
OSKARSHAMN-1
OSKARSHAMN-2
OSKARSHAMN-3
RINGHALS-1
RINGHALS-2
RINGHALS-3
RINGHALS-4
VANDELLOS-2
SE -9
SE -11
SE -14
SE -2
SE -3
SE -12
SE -4
SE -5
SE -7
SE -10
ES -16
Reactor
Name
Code
SWITZERLAND CH -1
CH -3
CH -4
CH -5
CH -2
SWEDEN
Country
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
NOK
NOK
KKG
KKL
BKW
FKA
FKA
FKA
OKG
OKG
OKG
RAB
RAB
RAB
RAB
ANAV
Operator
APC
APC
NPC
NPC
NPC
NPC
NPC
NPC
TNPG
TNPG
TNPG
WH
WH
KWU
GETSCO
GETSCO
ABBATOM
ABBATOM
ABBATOM
ABBATOM
ABBATOM
ABBATOM
ABBATOM
WH
WH
WH
WH
NSSS
Supplier
1965-10
1965-10
1968-10
1968-10
1970-12
1970-12
1980-8
1980-8
1967-9
1967-9
1967-11
1965-9
1968-1
1973-12
1974-1
1967-3
1973-6
1975-1
1979-1
1966-8
1969-9
1980-5
1969-2
1970-10
1972-9
1973-11
1980-12
Construction
Start
1983-4
1985-12
1983-8
1984-10
1983-7
1984-10
1988-7
1988-11
1976-10
1976-2
1976-2
1969-7
1971-10
1979-2
1984-5
1971-7
1980-6
1981-1
1985-3
1971-8
1974-10
1985-3
1974-10
1974-8
1980-9
1982-6
1987-12
1985-4
1989-4
1989-4
1989-4
1989-4
1989-4
1989-4
1989-4
1978-10
1976-9
1976-2
1969-9
1971-12
1979-11
1984-12
1972-11
1980-12
1981-7
1985-8
1972-2
1975-1
1985-8
1976-1
1975-5
1981-9
1983-11
1988-3
Grid
Commercial
Connection Operation
48.8
56.3
61.0
63.4
65.5
59.5
82.8
85.1
73.6
71.2
70.6
92.4
91.9
92.7
86.9
90.1
84.5
82.4
86.7
68.4
82.0
80.0
70.5
79.9
84.1
85.5
77.7
EAF %
2000 to
2009
49.2
56.7
61.1
63.4
65.7
59.7
83.0
85.5
73.7
71.4
70.7
92.6
92.0
93.1
87.9
91.9
86.9
84.4
89.0
69.2
83.4
80.8
72.1
82.1
86.9
87.4
78.6
DH
DH
PH
-
UCF %
Non2000 to electrical
2009
Applics
43
ARKANSAS ONE-1
ARKANSAS ONE-2
BEAVER VALLEY-1
BEAVER VALLEY-2
BRAIDWOOD-1
US -313
US -368
US -334
US -412
US -456
USA
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
GCR
GCR
GCR
PWR
GCR
GCR
GCR
GCR
Type
B&W (L-loop) D
CE (2-loop) DR
W (3-loop)
W (3-loop)
W (4-loop)
VVER V-320
VVER V-320
VVER V-213
VVER V-213
VVER V-320
VVER V-320
VVER V-302
VVER V-338
VVER V-320
VVER V-320
VVER V-320
VVER V-320
VVER V-320
VVER V-320
VVER V-320
AGR
MAGNOX
MAGNOX
SNUPPS
AGR
AGR
MAGNOX
MAGNOX
Model
2568
3026
2689
2689
3587
3000
3000
1375
1375
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
1496
730
660
3425
1623
1623
1920
1920
Thermal
880
1040
923
923
1240
1000
1000
420
415
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
644
230
230
1250
682
682
540
540
Gross
Capacity [MW]
The column Non-Electrical Applications indicates the use of the facility to provide: DH district heating.
KHMELNITSKI-1
KHMELNITSKI-2
ROVNO-1
ROVNO-2
ROVNO-3
ROVNO-4
SOUTH UKRAINE-1
SOUTH UKRAINE-2
SOUTH UKRAINE-3
ZAPOROZHE-1
ZAPOROZHE-2
ZAPOROZHE-3
ZAPOROZHE-4
ZAPOROZHE-5
ZAPOROZHE-6
UA -40
UA -41
UA -27
UA -28
UA -29
UA -69
UA -44
UA -45
UA -48
UA -54
UA -56
UA -78
UA -79
UA -126
UA -127
Name
HUNTERSTON-B2
OLDBURY-A1
OLDBURY-A2
SIZEWELL-B
TORNESS 1
TORNESS 2
WYLFA 1
WYLFA 2
Code
GB -17B
GB -11A
GB -11B
GB -24
GB -23A
GB -23B
GB -13A
GB -13B
Reactor
UKRAINE
Country
842
997
892
846
1178
950
950
381
376
950
950
950
950
950
950
950
950
950
950
950
430
217
217
1188
600
605
490
490
Net
ENTGARKS
ENTERGY
FENOC
FENOC
EXELON
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
NNEGC
BE
MEL
MEL
BE
BE
BE
MEL
MEL
Operator
B&W
CE
WH
WH
WH
PAIP
PAIP
PAIP
PAIP
PAIP
PAA
PAA
PAA
PAA
PAIP
PAIP
PAIP
PAIP
PAIP
PAIP
TNPG
TNPG
TNPG
PPC
NNC
NNC
EE/B&W/T
EE/B&W/T
NSSS
Supplier
1968-12
1968-12
1970-6
1974-5
1975-12
1981-11
1985-2
1973-8
1973-10
1980-2
1986-8
1977-3
1979-10
1985-2
1980-4
1981-1
1982-4
1983-4
1985-11
1986-6
1967-11
1962-5
1962-5
1988-7
1980-8
1980-8
1963-9
1963-9
Construction
Start
1974-8
1978-12
1976-6
1987-8
1987-7
1987-12
2004-8
1980-12
1981-12
1986-12
2004-10
1982-12
1985-1
1989-9
1984-12
1985-7
1986-12
1987-12
1989-8
1995-10
1977-3
1967-11
1968-4
1995-2
1988-5
1989-2
1971-1
1971-7
1974-12
1980-3
1976-10
1987-11
1988-7
1988-8
2005-12
1981-9
1982-7
1987-5
2006-4
1983-10
1985-4
1989-12
1985-12
1986-2
1987-3
1988-4
1989-10
1996-9
1977-3
1967-12
1968-9
1995-9
1988-5
1989-2
1971-11
1972-1
Grid
Commercial
Connection Operation
90.7
91.3
90.6
92.8
96.0
79.5
76.1
72.1
81.7
67.4
65.9
71.0
73.8
71.1
76.7
79.3
80.2
81.0
79.9
80.8
73.6
52.1
69.4
87.0
77.5
73.1
65.1
61.5
EAF %
2000 to
2009
90.7
91.3
90.6
92.8
96.0
81.1
77.0
73.1
83.1
70.3
68.9
72.7
75.2
73.2
78.1
81.0
83.9
85.0
82.3
82.6
73.7
52.1
69.4
87.1
78.1
73.8
65.5
61.8
DH
DH
DH
DH
DH
DH
DH
DH
DH
DH
DH
DH
DH
DH
DH
UCF %
Non2000 to electrical
2009
Applics
44
Country
Name
BRAIDWOOD-2
BROWNS FERRY-1
BROWNS FERRY-2
BROWNS FERRY-3
BRUNSWICK-1
BRUNSWICK-2
BYRON-1
BYRON-2
CALLAWAY-1
CALVERT CLIFFS-1
CALVERT CLIFFS-2
CATAWBA-1
CATAWBA-2
CLINTON-1
COLUMBIA
COMANCHE PEAK-1
COMANCHE PEAK-2
COOPER
CRYSTAL RIVER-3
DAVIS BESSE-1
DIABLO CANYON-1
DIABLO CANYON-2
DONALD COOK-1
DONALD COOK-2
DRESDEN-2
DRESDEN-3
DUANE ARNOLD-1
ENRICO FERMI-2
FARLEY-1
FARLEY-2
Code
US -457
US -259
US -260
US -296
US -325
US -324
US -454
US -455
US -483
US -317
US -318
US -413
US -414
US -461
US -397
US -445
US -446
US -298
US -302
US -346
US -275
US -323
US -315
US -316
US -237
US -249
US -331
US -341
US -348
US -364
Reactor
PWR
BWR
BWR
BWR
BWR
BWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
BWR
BWR
PWR
PWR
BWR
PWR
PWR
PWR
PWR
PWR
PWR
BWR
BWR
BWR
BWR
PWR
PWR
Type
W (4-loop) DRY
BWR-4
BWR-4 (Mark 1)
BWR-4 (Mark 1)
BWR-4 (Mark 1)
BWR-4 (Mark 1)
W (4-loop) (DR
W (4-Loop) (DR
W (4-loop) DRY
CE (2-loop) (D
CE (2-loop) (D
W (4-loop) (IC
W (4-loop) (IC
BWR-6 (Mark 3)
BWR-5 (Mark 2)
W (4-loop) DRY
W (4-loop) DRY
BWR-4 (Mark 1)
B&W (L-loop)
B&W (R-loop)
W (4-loop)
W (4-loop)
W (4-loop) ICE
W (4-loop) ICE
BWR-3 (Mark 1)
BWR-3 (Mark 1)
BWR-4 (Mark 1)
BWR-4 (Mark 1)
W (3-loop)
W (3-loop) DRY
Model
3587
3458
3458
3458
2923
2923
3587
3587
3565
2700
2700
3411
3411
3473
3486
3458
3458
2381
2568
2772
3338
3411
3304
3468
2527
2527
1912
3430
2775
2775
Thermal
1213
1152
1155
1400
990
989
1225
1196
1236
918
911
1188
1188
1098
1200
1189
1189
801
890
925
1136
1164
1077
1133
913
913
614
1154
895
905
Gross
Capacity [MW]
1152
1065
1103
1104
938
920
1164
1136
1190
873
862
1129
1129
1043
1131
1209
1158
769
860
879
1122
1118
1009
1060
867
867
579
1122
851
860
Net
EXELON
TVA
TVA
TVA
PROGENGC
PROGENGC
EXELON
EXELON
AMERGENE
CCNPP
CCNPP
DUKE
DUKE
AMERGENE
ENERGYNW
TXU
TXU
NPPD
PROGRESS
FENOC
PGE
PGE
IMPCO
IMPCO
EXELON
EXELON
FPLDUANE
DETED
ALP
ALP
Operator
WH
GE
GE
GE
GE
GE
WH
WH
WH
CE
CE
WH
WH
GE
GE
WH
WH
GE
B&W
B&W
WH
WH
WH
WH
GE
GE
GE
GE
WH
WH
NSSS
Supplier
1975-12
1967-5
1967-5
1968-7
1970-2
1970-2
1975-12
1975-12
1976-4
1969-7
1969-7
1975-8
1975-8
1976-2
1972-2
1974-12
1974-12
1968-6
1968-9
1971-3
1968-4
1970-12
1969-3
1969-3
1966-1
1966-10
1970-6
1972-9
1972-8
1972-8
Construction
Start
1988-5
1973-10
1974-8
1976-9
1976-12
1975-4
1985-3
1987-2
1984-10
1975-1
1976-12
1985-1
1986-5
1987-4
1984-5
1990-4
1993-4
1974-5
1977-1
1977-8
1984-11
1985-10
1975-2
1978-3
1970-4
1971-7
1974-5
1986-9
1977-8
1981-5
1988-10
1974-8
1975-3
1977-3
1977-3
1975-11
1985-9
1987-8
1984-12
1975-5
1977-4
1985-6
1986-8
1987-11
1984-12
1990-8
1993-8
1974-7
1977-3
1978-7
1985-5
1986-3
1975-8
1978-7
1970-6
1971-11
1975-2
1988-1
1977-12
1981-7
Grid
Commercial
Connection Operation
95.2
89.2
91.7
93.2
92.8
91.9
95.0
96.0
89.3
91.7
93.9
91.1
91.5
93.9
89.3
93.1
93.6
86.7
91.1
73.2
90.1
90.5
69.1
83.9
93.1
93.8
92.4
88.2
90.3
91.7
EAF %
2000 to
2009
95.3
89.2
91.7
93.2
92.9
91.9
95.0
96.0
89.3
91.7
93.9
91.1
91.5
94.0
89.3
93.1
93.6
86.7
91.2
73.2
90.1
90.7
69.2
83.9
93.1
93.8
92.6
88.2
90.3
91.7
UCF %
Non2000 to electrical
2009
Applics
45
Country
Name
FITZPATRICK
FORT CALHOUN-1
GRAND GULF-1
H.B. ROBINSON-2
HATCH-1
HATCH-2
HOPE CREEK-1
INDIAN POINT-2
INDIAN POINT-3
KEWAUNEE
LASALLE-1
LASALLE-2
LIMERICK-1
LIMERICK-2
MCGUIRE-1
MCGUIRE-2
MILLSTONE-2
MILLSTONE-3
MONTICELLO
NINE MILE POINT-1
NINE MILE POINT-2
NORTH ANNA-1
NORTH ANNA-2
OCONEE-1
OCONEE-2
OCONEE-3
OYSTER CREEK
PALISADES
PALO VERDE-1
PALO VERDE-2
Code
US -333
US -285
US -416
US -261
US -321
US -366
US -354
US -247
US -286
US -305
US -373
US -374
US -352
US -353
US -369
US -370
US -336
US -423
US -263
US -220
US -410
US -338
US -339
US -269
US -270
US -287
US -219
US -255
US -528
US -529
Reactor
BWR
PWR
BWR
PWR
BWR
BWR
BWR
PWR
PWR
PWR
BWR
BWR
BWR
BWR
PWR
PWR
PWR
PWR
BWR
BWR
BWR
PWR
PWR
PWR
PWR
PWR
BWR
PWR
PWR
PWR
Type
BWR-4 (Mark 1)
CE (2-loop)
BWR-6 (Mark 3)
W (3-loop) DRY
BWR-4 (Mark 1)
BWR-4 (Mark 1)
BWR-4 (Mark 1)
W (4-loop) DRY
W (4-loop) DRY
W (2-loop) DRY
BWR-5 (Mark 2)
BWR-5 (Mark 2)
BWR-4 (Mark 2)
BWR-4 (Mark 2)
W (4-loop) ICE
W (4-loop) (IC
COMB CE DRYA
W (4-loop) DRY
BWR-3
BWR-2 (Mark 1)
BWR-5 (Mark 2)
W (3-loop)
W (3-loop)
B&W (L-loop)
B&W (L-loop)
B&W (L-loop)
BWR-2 (Mark 1)
CE (2-loop) DR
CE (2-loop) DR
COMB CE80 DR
Model
2536
1500
3833
2339
2804
2804
3339
3216
3216
1772
3489
3489
3458
3458
3411
3411
2700
3411
1775
1850
3467
2893
2893
2568
2568
2568
1930
2565
3990
3990
Thermal
882
512
1333
745
898
921
1376
1062
1065
581
1177
1179
1194
1194
1158
1158
910
1253
600
642
1205
973
958
891
891
891
652
842
1414
1414
Gross
Capacity [MW]
854
482
1259
710
876
883
1161
1025
1040
556
1118
1120
1130
1134
1100
1100
877
1137
572
621
1142
903
903
846
846
846
614
778
1311
1314
Net
ENTERGY
OPPD
ENTERGY
PROGRESS
SOUTH
SOUTH
PSEG
ENTERGY
ENTERGY
DOMENGY
EXELON
EXELON
EXELON
EXELON
DUKE
DUKE
DOMIN
DOMIN
NORTHERN
NMPNSLLC
NMPNSLLC
VEPCO
VEPCO
DUKE
DUKE
DUKE
AMERGENE
CONSENEC
AZPSCO
AZPSCO
Operator
GE
CE
GE
WH
GE
GE
GE
WH
WH
WH
GE
GE
GE
GE
WH
WH
CE
WH
GE
GE
GE
WH
WH
B&W
B&W
B&W
GE
CE
CE
CE
NSSS
Supplier
1970-5
1968-6
1974-9
1967-4
1969-9
1972-12
1976-3
1966-10
1969-8
1968-8
1973-9
1973-9
1974-6
1974-6
1973-2
1973-2
1970-12
1974-8
1967-6
1965-4
1974-6
1971-2
1971-2
1967-11
1967-11
1967-11
1964-12
1967-3
1976-5
1976-6
Construction
Start
1975-2
1973-8
1984-10
1970-9
1974-11
1978-9
1986-8
1973-6
1976-4
1974-4
1982-9
1984-4
1985-4
1989-9
1981-9
1983-5
1975-11
1986-2
1971-3
1969-11
1987-8
1978-4
1980-8
1973-5
1973-12
1974-9
1969-9
1971-12
1985-6
1986-5
1975-7
1973-9
1985-7
1971-3
1975-12
1979-9
1986-12
1974-8
1976-8
1974-6
1984-1
1984-10
1986-2
1990-1
1981-12
1984-3
1975-12
1986-4
1971-6
1969-12
1988-3
1978-6
1980-12
1973-7
1974-9
1974-12
1969-12
1971-12
1986-1
1986-9
Grid
Commercial
Connection Operation
94.1
87.2
93.5
93.1
91.8
90.6
88.0
87.0
94.2
84.9
96.4
94.7
96.5
95.9
91.6
91.9
88.8
92.3
90.2
91.6
92.2
92.7
88.5
87.4
91.5
88.3
92.8
84.1
85.8
86.3
EAF %
2000 to
2009
94.3
87.2
93.8
93.1
91.8
90.6
88.0
87.0
94.2
84.9
96.4
94.7
96.5
95.9
91.6
91.9
88.9
92.4
90.2
91.6
92.2
92.7
88.6
87.4
91.5
88.3
92.9
84.2
85.9
86.6
UCF %
Non2000 to electrical
2009
Applics
46
Country
Name
PALO VERDE-3
PEACH BOTTOM-2
PEACH BOTTOM-3
PERRY-1
PILGRIM-1
POINT BEACH-1
POINT BEACH-2
PRAIRIE ISLAND-1
PRAIRIE ISLAND-2
QUAD CITIES-1
QUAD CITIES-2
R.E. GINNA
RIVER BEND-1
SALEM-1
SALEM-2
SAN ONOFRE-2
SAN ONOFRE-3
SEABROOK-1
SEQUOYAH-1
SEQUOYAH-2
SHEARON HARRIS-1
SOUTH TEXAS-1
SOUTH TEXAS-2
ST. LUCIE-1
ST. LUCIE-2
SURRY-1
SURRY-2
SUSQUEHANNA-1
SUSQUEHANNA-2
THREE MILE ISLAND-1
Code
US -530
US -277
US -278
US -440
US -293
US -266
US -301
US -282
US -306
US -254
US -265
US -244
US -458
US -272
US -311
US -361
US -362
US -443
US -327
US -328
US -400
US -498
US -499
US -335
US -389
US -280
US -281
US -387
US -388
US -289
Reactor
PWR
BWR
BWR
BWR
BWR
PWR
PWR
PWR
PWR
BWR
BWR
PWR
BWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
BWR
BWR
PWR
Type
COMB CE80 DR
BWR-4 (Mark 1)
BWR-4 (Mark 1)
BWR-6 (Mark 3)
BWR-3 (Mark 1)
W (2-loop) DRY
W (2-loop) DRY
W (2-loop) DRY
W (2-loop) DRY
BWR-3 (Mark 1)
BWR-3 (Mark 1)
W (2-loop)
BWR-6 (Mark 3)
W (4-loop) DRY
W (4-loop) DRY
CE (2-loop) DR
CE (2-loop) DR
W (4-loop) DRY
W (4-loop) ICE
W (4-loop) (IC
W (3-loop) DRY
W (4-loop)
W (4-loop) DRY
COMB CE DRYA
COMB CE DRYA
W (3-loop) DRY
W (3-loop) DRY
BWR-4 (Mark 2)
BWR-4 (Mark 2)
B&W (L-loop)
Model
3990
3514
3514
3758
2028
1540
1540
1650
1650
2957
2511
1775
3091
3459
3459
3438
3438
3587
3411
3411
2900
3853
3853
2700
2700
2546
2546
3489
3489
2568
Thermal
1346
1171
1171
1303
711
543
545
566
640
913
913
608
1036
1228
1170
1127
1127
1296
1221
1221
960
1354
1354
883
883
848
848
1199
1204
837
Gross
Capacity [MW]
1317
1112
1112
1245
684
510
516
551
545
867
867
580
978
1174
1158
1070
1080
1245
1148
1126
900
1280
1280
839
839
799
799
1185
1140
786
Net
AZPSCO
EXELON
EXELON
FENOC
ENTERGY
WEP
WEP
NORTHERN
NMC
EXELON
EXELON
CCNPP
ENTGS
PSEGPOWR
PSEGPOWR
SCE
SCE
FPL
TVA
TVA
PROGENGC
STP
STP
FPL
FPL
VEPCO
VEPCO
PP&L
PP&L
AMERGENE
Operator
CE
GE
GE
GE
GE
WH
WH
WH
WH
GE
GE
WH
GE
WH
WH
CE
CE
WH
WH
WH
WH
WH
WH
CE
CE
WH
WH
GE
GE
B&W
NSSS
Supplier
1976-6
1968-1
1968-1
1977-5
1968-8
1967-7
1968-7
1968-6
1969-6
1967-2
1967-2
1966-4
1977-3
1968-9
1968-9
1974-3
1974-3
1976-7
1970-5
1970-5
1978-1
1975-12
1975-12
1970-7
1977-5
1968-6
1968-6
1973-11
1973-11
1968-5
Construction
Start
1987-11
1974-2
1974-9
1986-12
1972-7
1970-11
1972-8
1973-12
1974-12
1972-4
1972-5
1969-12
1985-12
1976-12
1981-6
1982-9
1983-9
1990-5
1980-7
1981-12
1987-1
1988-3
1989-4
1976-5
1983-6
1972-7
1973-3
1982-11
1984-7
1974-6
1988-1
1974-7
1974-12
1987-11
1972-12
1970-12
1972-10
1973-12
1974-12
1973-2
1973-3
1970-7
1986-6
1977-6
1981-10
1983-8
1984-4
1990-8
1981-7
1982-6
1987-5
1988-8
1989-6
1976-12
1983-8
1972-12
1973-5
1983-6
1985-2
1974-9
Grid
Commercial
Connection Operation
85.6
95.3
96.0
86.2
94.3
90.6
89.2
89.8
92.1
93.9
93.8
94.5
90.3
91.5
90.6
85.5
85.1
89.9
90.2
91.7
91.5
89.1
90.4
92.6
87.0
91.0
91.7
92.0
93.0
93.2
EAF %
2000 to
2009
85.8
95.3
96.0
86.2
94.3
90.6
89.2
89.8
92.1
93.9
93.8
94.5
90.9
91.5
90.6
85.5
85.2
90.2
90.2
91.7
91.5
89.1
90.4
93.1
87.8
91.0
91.7
92.0
93.0
93.3
UCF %
Non2000 to electrical
2009
Applics
47
2300
2300
1912
2900
3565
3565
3716
3459
3565
Thermal
729
729
650
1003
1203
1202
1200
1202
1213
Gross
Capacity [MW]
693
693
620
966
1150
1152
1176
1123
1160
Net
Operator
NSSS
Supplier
GE
GE
GE
GE
WH
WH
W (3-loop) DRY
W (3-loop) DRY
BWR-4 (Mark 1)
W (3-loop) DRY
W (4-loop) DRY
W (4-loop) DRY
CE (2-loop)
W (4-loop) (IC
W (4-loop)
Model
Status as of 31 December 2009, 437 reactors (370705 MW) were connected to the grid, including 6 units (4980 MW) in Taiwan, China.
TW -1 CHIN SHAN-1
BWR BWR-4
1804
636
604 TPC
TAIWAN, CN
TW -2 CHIN SHAN-2
BWR BWR-4
1775
636
604 TPC
TAIWAN, CN
TW -3 KUOSHENG-1
BWR BWR-6
2943
1019
985 TPC
TAIWAN, CN
TW -4 KUOSHENG-2
BWR BWR-6
2943
985
948 TPC
TAIWAN, CN
TW -5 MAANSHAN-1
PWR WE 312 (3 loop
2822
956
918 TPC
TAIWAN, CN
TW -6 MAANSHAN-2
PWR WE 312 (3 loop
2822
958
921 TPC
TAIWAN, CN
PWR
PWR
BWR
PWR
PWR
PWR
PWR
PWR
PWR
Type
WH
WH
GE
WH
WH
WH
CE
WH
WH
Name
TURKEY POINT-3
TURKEY POINT-4
VERMONT YANKEE
VIRGIL C. SUMMER-1
VOGTLE-1
VOGTLE-2
WATERFORD-3
WATTS BAR-1
WOLF CREEK
Code
US -250
US -251
US -271
US -395
US -424
US -425
US -382
US -390
US -482
Reactor
FPL
FPL
ENTERGY
SCEG
SOUTH
SOUTH
ENTERGY
TVA
KGECO
Country
1972-6
1973-12
1975-11
1976-3
1978-8
1979-2
1967-4
1967-4
1967-12
1973-3
1976-8
1976-8
1974-11
1973-1
1977-5
Construction
Start
1977-11
1978-12
1981-5
1982-6
1984-5
1985-2
1972-11
1973-6
1972-9
1982-11
1987-3
1989-4
1985-3
1996-2
1985-6
1978-12
1979-7
1981-12
1983-3
1984-7
1985-5
1972-12
1973-9
1972-11
1984-1
1987-6
1989-5
1985-9
1996-5
1985-9
Grid
Commercial
Connection Operation
89.7
88.3
86.7
86.9
88.9
89.1
90.5
90.6
95.0
86.9
92.2
91.1
91.2
89.9
90.7
EAF %
2000 to
2009
90.1
88.9
87.5
88.2
91.0
90.7
90.8
90.8
95.0
86.9
92.2
91.1
91.9
89.9
90.7
UCF %
Non2000 to electrical
2009
Applics
48
JP -31
Name
MONJU
BRUCE-1
BRUCE-2
PICKERING-2
PICKERING-3
Reactor
FBR
PHWR
PHWR
PHWR
PHWR
Type
280
714
Not specified
Gross
824
824
542
542
Thermal
Capacity [MW]
2832
2832
1744
1744
Model
CANDU 791
CANDU 791
CANDU 500A
CANDU 500A
JAPAN
Code
CA -8
CA -9
CA -5
CA -6
CANADA
Country
246
848
848
515
515
Net
JAEA
BRUCEPOW
BRUCEPOW
OPG
OPG
Operator
T/H/F/M
OH/AECL
OH/AECL
OH/AECL
OH/AECL
NSSS
Supplier
1986-5
1971-6
1970-12
1966-9
1967-12
Construction
Start
1995-8
1977-1
1976-9
1971-10
1972-5
Grid
Connection
1977-9
1977-9
1971-12
1972-6
Commercial
Operation
1995-12
1997-10
1995-10
1997-12
1997-12
Long-term
Shutdown
Date
49
AM -18
BE -1
BG -1
BG -2
BG -3
BG -4
CA -2
CA -3
CA -1
FR -9
FR -2
FR -3
FR -4
FR -5
FR -6
FR -1B
FR -1
FR -7
FR -8
FR -24
DE -4
DE -502
DE -503
DE -504
DE -505
ARMENIA
BULGARIA
CANADA
FRANCE
GERMANY
Code
BELGIUM
Country
Reactor
BUGEY-1
CHINON-A1
CHINON-A2
CHINON-A3
CHOOZ-A (ARDENNES)
EL-4 (MONTS D'ARREE)
G-2 (MARCOULE)
G-3 (MARCOULE)
ST. LAURENT-A1
ST. LAURENT-A2
SUPER-PHENIX
DOUGLAS POINT
GENTILLY-1
ROLPHTON NPD
KOZLODUY-1
KOZLODUY-2
KOZLODUY-3
KOZLODUY-4
BR-3
ARMENIA-1
Name
HTGR
PWR
PWR
PWR
PWR
GCR
GCR
GCR
GCR
PWR
HWGCR
GCR
GCR
GCR
GCR
FBR
PHWR
HWLWR
PHWR
PWR
PWR
PWR
PWR
PWR
PWR
Type
46
1375
1375
1375
1375
1954
300
800
1170
1040
250
260
260
1650
1475
3000
704
792
92
1375
1375
1375
1375
41
1375
Thermal
15
440
440
440
440
555
80
230
480
320
75
43
43
500
530
1242
218
266
25
440
440
440
440
12
408
Gross
Capacity [MW]
13
408
408
408
408
540
70
180
360
305
70
39
40
390
465
1200
206
250
22
408
408
408
408
10
376
Net
AVR
EWN
EWN
EWN
EWN
EDF
EDF
EDF
EDF
SENA
EDF
COGEMA
COGEMA
EDF
EDF
EDF
OH
HQ
OH
KOZNPP
KOZNPP
KOZNPP
KOZNPP
CEN/SCK
ANPPJSC
Operator
BBK
AtEE
AtEE
AtEE
AtEE
FRAM
LEVIVIER
LEVIVIER
GTM
A/F/W
GAAA
SACM
SACM
FRAM
FRAM
ASPALDO
AECL
AECL
CGE
AEE
AEE
AEE
AEE
WH
FAEA
NSSS
Supplier
1961-8
1970-3
1970-3
1972-4
1972-4
1965-12
1957-2
1959-8
1961-3
1962-1
1962-7
1955-3
1956-3
1963-10
1966-1
1976-12
1960-2
1966-9
1958-1
1970-4
1970-4
1973-10
1973-10
1957-11
1969-7
Construction
Start
1967-12
1973-12
1974-12
1977-10
1979-9
1972-4
1963-6
1965-2
1966-8
1967-4
1967-7
1959-4
1960-4
1969-3
1971-8
1986-1
1967-1
1971-4
1962-6
1974-7
1975-8
1980-12
1982-5
1962-10
1976-12
Grid
Connection
1969-5
1974-7
1975-4
1978-5
1979-11
1972-7
1964-2
1965-2
1966-8
1967-4
1968-6
1959-4
1960-4
1969-6
1971-11
1986-12
1968-9
1972-5
1962-10
1974-10
1975-11
1981-1
1982-6
1962-10
1977-10
Commercial
Operation
1988-12
1990-2
1990-2
1990-2
1990-7
1994-5
1973-4
1985-6
1990-6
1991-10
1985-7
1980-2
1984-6
1990-4
1992-5
1998-12
1984-5
1977-6
1987-8
2002-12
2002-12
2006-12
2006-12
1987-6
1989-2
Shut Down
50
IT -4
IT -3
IT -2
IT -1
JP -20
JP -11
JP -24
JP -1
JP -2
KZ -10
LT -46
LT -47
ITALY
JAPAN
KAZAKHSTAN
LITHUANIA
NETHERLANDS NL -1
DE -506
DE -3
DE -7
DE -8
DE -6
DE -22
DE -2
DE -11
DE -5
DE -501
DE -10
DE -19
DE -1
DE -9
Code
GERMANY
Country
Reactor
DODEWAARD
IGNALINA-1
IGNALINA-2
BN-350
FUGEN ATR
HAMAOKA-1
HAMAOKA-2
JPDR
TOKAI-1
CAORSO
ENRICO FERMI (TRINO)
GARIGLIANO
LATINA
GREIFSWALD-5 (KGR 5)
GUNDREMMINGEN-A (KRB A)
HDR GROSSWELZHEIM
KNK II
LINGEN (KWL)
MUELHEIM-KAERLICH (KMK)
MZFR
NIEDERAICHBACH (KKN)
OBRIGHEIM (KWO)
RHEINSBERG (KKR)
STADE (KKS)
THTR-300
VAK KAHL
WUERGASSEN (KWW)
Name
BWR
LWGR
LWGR
FBR
HWLWR
BWR
BWR
BWR
GCR
BWR
PWR
BWR
GCR
PWR
BWR
BWR
FBR
BWR
PWR
PHWR
HWGCR
PWR
PWR
PWR
HTGR
BWR
BWR
Type
183
4800
4800
1000
557
1593
2436
90
587
2651
870
506
660
1375
801
100
58
520
3760
200
321
1050
265
1900
750
60
1912
Thermal
60
1300
1300
90
165
540
840
13
166
882
270
160
160
440
250
25
21
268
1302
57
106
357
70
672
308
16
670
Gross
Capacity [MW]
55
1185
1185
52
148
515
806
12
137
860
260
150
153
408
237
25
17
183
1219
52
100
340
62
640
296
15
640
Net
BV GKN
INPP
INPP
MAEC-KAZ
JAEA
CHUBU
CHUBU
JAEA
JAPCO
SOGIN
SOGIN
SOGIN
SOGIN
EWN
KGB
HDR
KBG
KWL
KGG
KBG
KKN
EnBW
EWN
E.ON
HKG
VAK
PE
Operator
RDM
MAEP
MAEP
1965-5
1977-5
1978-1
1964-10
1972-5
1971-6
1974-6
1960-12
1961-3
HITACHI
TOSHIBA
TOSHIBA
GE
GEC
MAEC-KAZ
1970-1
1961-7
1959-11
1958-11
1976-12
1962-12
1965-1
1974-9
1964-10
1975-1
1961-12
1966-6
1965-3
1960-1
1967-12
1971-5
1958-7
1968-1
Construction
Start
AMN/GETS
EL/WEST
GE
TNPG
AtEE
AEG,GE
AEG,KWU
IA
AEG
BBR
SIEMENS
SIEM,KWU
SIEM,KWU
AtEE
KWU
HRB
GE,AEG
AEG,KWU
NSSS
Supplier
1968-10
1983-12
1987-8
1973-7
1978-7
1974-8
1978-5
1963-10
1965-11
1978-5
1964-10
1964-1
1963-5
1989-4
1966-12
1969-10
1978-4
1968-7
1986-3
1966-3
1973-1
1968-10
1966-5
1972-1
1985-11
1961-6
1971-12
Grid
Connection
1969-3
1984-5
1987-8
1973-7
1979-3
1976-3
1978-11
1965-3
1966-7
1981-12
1965-1
1964-6
1964-1
1989-11
1967-4
1970-8
1979-3
1968-10
1987-8
1966-12
1973-1
1969-3
1966-10
1972-5
1987-6
1962-2
1975-11
Commercial
Operation
Shut Down
1997-3
2004-12
2009-12
1999-4
2003-3
2009-1
2009-1
1976-3
1998-3
1990-7
1990-7
1982-3
1987-12
1989-11
1977-1
1971-4
1991-8
1979-1
1988-9
1984-5
1974-7
2005-5
1990-6
2003-11
1988-4
1985-11
1994-8
51
GB -3A
GB -3B
GB -4A
GB -4B
GB -1A
GB -1B
GB -1C
GB -1D
GB -2A
GB -2B
GB -2C
GB -2D
GB -14
GB -15
UK
BERKELEY 1
BERKELEY 2
BRADWELL 1
BRADWELL 2
CALDER HALL 1
CALDER HALL 2
CALDER HALL 3
CALDER HALL 4
CHAPELCROSS 1
CHAPELCROSS 2
CHAPELCROSS 3
CHAPELCROSS 4
DOUNREAY DFR
DOUNREAY PFR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
FBR
FBR
PHWR
BWR
BWR
AGESTA
BARSEBACK-1
BARSEBACK-2
SE -1
SE -6
SE -8
SWEDEN
PWR
GCR
ES -1
ES -3
SPAIN
HWGCR
PWR
PWR
LWGR
LWGR
LWGR
PWR
PWR
Type
BOHUNICE A1
BOHUNICE-1
BOHUNICE-2
SK -1
SK -2
SK -3
SLOVAKIA
Reactor
APS-1 OBNINSK
BELOYARSKY-1
BELOYARSKY-2
NOVOVORONEZH-1
NOVOVORONEZH-2
Name
RU -1
RU -3
RU -6
RU -4
RU -8
Code
RUSSIA
Country
620
620
481
481
268
268
268
268
260
260
260
260
60
600
80
1800
1800
510
1670
560
1375
1375
30
286
530
760
1320
Thermal
166
166
146
146
60
60
60
60
60
60
60
60
15
250
12
615
615
150
500
143
440
440
6
108
160
210
365
Gross
Capacity [MW]
138
138
123
123
49
49
49
49
48
48
48
48
11
234
10
600
600
141
480
93
408
408
5
102
146
197
336
Net
MEL
MEL
MEL
MEL
MEL
MEL
MEL
MEL
MEL
MEL
MEL
MEL
UKAEA
UKAEA
BKAB
BKAB
BKAB
UFG
HIFRENSA
JAVYS
JAVYS
JAVYS
MSM
MSM
MSM
MSM
MSM
Operator
TNPG
TNPG
TNPG
TNPG
UKAEA
UKAEA
UKAEA
UKAEA
UKAEA
UKAEA
UKAEA
UKAEA
UKAEA
TNPG
ABBATOM
ASEASTAL
ABBATOM
WH
CEA
SKODA
AEE
AEE
MSM
MSM
MSM
MSM
MSM
NSSS
Supplier
1957-1
1957-1
1957-1
1957-1
1953-8
1953-8
1955-8
1955-8
1955-10
1955-10
1955-10
1955-10
1955-3
1966-1
1957-12
1971-2
1973-1
1964-6
1968-6
1958-8
1972-4
1972-4
1951-1
1958-6
1962-1
1957-7
1964-6
Construction
Start
1962-6
1962-6
1962-7
1962-7
1956-8
1957-2
1958-3
1959-4
1959-2
1959-7
1959-11
1960-1
1962-10
1975-1
1964-5
1975-5
1977-3
1968-7
1972-5
1972-12
1978-12
1980-3
1954-6
1964-4
1967-12
1964-9
1969-12
Grid
Connection
1962-6
1962-10
1962-7
1962-11
1956-10
1957-2
1958-5
1959-4
1959-3
1959-8
1959-12
1960-3
1962-10
1976-7
1964-5
1975-7
1977-7
1969-8
1972-8
1972-12
1980-4
1981-1
1954-12
1964-4
1969-12
1964-12
1970-4
Commercial
Operation
1989-3
1988-10
2002-3
2002-3
2003-3
2003-3
2003-3
2003-3
2004-6
2004-6
2004-6
2004-6
1977-3
1994-3
1974-6
1999-11
2005-5
2006-4
1990-7
1977-2
2006-12
2008-12
2002-4
1983-1
1990-4
1988-2
1990-8
Shut Down
52
CHERNOBYL-1
CHERNOBYL-2
CHERNOBYL-3
CHERNOBYL-4
UA -25
UA -26
UA -42
UA -43
US -155
US -014
US -144
US -10
US -011
US -16
US -267
US -018
US -213
US -077
US -133
US -013
US -409
UKRAINE
USA
Reactor
DUNGENESS-A1
DUNGENESS-A2
HINKLEY POINT-A1
HINKLEY POINT-A2
HUNTERSTON-A1
HUNTERSTON-A2
SIZEWELL-A1
SIZEWELL-A2
TRAWSFYNYDD 1
TRAWSFYNYDD 2
WINDSCALE AGR
WINFRITH SGHWR
Name
GB -9A
GB -9B
GB -7A
GB -7B
GB -6A
GB -6B
GB -10A
GB -10B
GB -8A
GB -8B
GB -5
GB -12
Code
UK
Country
BWR
BWR
PHWR
BWR
BWR
FBR
HTGR
BWR
PWR
X
BWR
PWR
BWR
LWGR
LWGR
LWGR
LWGR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
GCR
SGHWR
Type
240
50
65
700
58
200
842
50
1825
256
220
615
165
3200
3200
3200
3200
840
840
900
900
595
595
1010
1010
850
850
120
318
Thermal
71
18
19
207
24
65
342
24
603
84
65
277
55
800
1000
1000
1000
230
230
267
267
173
173
245
245
235
235
36
100
Gross
Capacity [MW]
67
17
17
197
22
61
330
24
560
75
63
257
48
740
925
925
925
225
225
235
235
150
150
210
210
195
195
24
92
Net
CPC
DOE/PRWR
CVPA
EXELON
RCPA
DETED
PSCC
GE
CYAPC
AEC/NPPD
PGE
ENTERGY
DPC
MTE
MTE
MTE
MTE
MEL
MEL
MEL
MEL
MEL
MEL
MEL
MEL
MEL
MEL
UKAEA
UKAEA
Operator
GE
GNEPRWRA
WH
GE
AC
UEC
GA
GE
WH
GE
GE
B&W
AC
FAEA
FAEA
FAEA
FAEA
TNPG
TNPG
EE/B&W/T
EE/B&W/T
GEC
GEC
EE/B&W/T
EE/B&W/T
APC
APC
UKAEA
ICL/FE
NSSS
Supplier
1960-5
1960-1
1960-1
1956-5
1959-1
1956-8
1968-9
1956-1
1964-5
1959-1
1960-11
1956-5
1963-3
1970-3
1973-2
1976-3
1979-4
1960-7
1960-7
1957-11
1957-11
1957-10
1957-10
1961-4
1961-4
1959-7
1959-7
1958-11
1963-5
Construction
Start
1962-12
1964-8
1963-12
1960-4
1963-8
1966-8
1976-12
1957-10
1967-8
1963-9
1963-4
1962-9
1968-4
1977-9
1978-12
1981-12
1983-12
1965-9
1965-11
1965-2
1965-3
1964-2
1964-6
1966-1
1966-4
1965-1
1965-2
1963-2
1967-12
Grid
Connection
1963-3
1965-9
NA
1960-7
1964-7
NA
1979-7
1957-10
1968-1
1963-11
1963-8
1962-10
1969-11
1978-5
1979-5
1982-6
1984-3
1965-10
1965-12
1965-3
1965-5
1964-2
1964-7
1966-3
1966-9
1965-3
1965-3
1963-3
1968-1
Commercial
Operation
Shut Down
1997-8
1968-6
1967-1
1978-10
1968-2
1972-11
1989-8
1963-12
1996-12
1964-9
1976-7
1974-10
1987-4
1996-11
1991-10
2000-12
1986-4
2006-12
2006-12
2000-5
2000-5
1990-3
1989-12
2006-12
2006-12
1991-2
1991-2
1981-4
1990-9
53
US -309
US -245
US -130
US -171
US -012
US -312
US -206
US -146
US -001
US -322
US -320
US -344
US -29
US -295
US -304
Code
Reactor
MAINE YANKEE
MILLSTONE-1
PATHFINDER
PEACH BOTTOM-1
PIQUA
RANCHO SECO-1
SAN ONOFRE-1
SAXTON
SHIPPINGPORT
SHOREHAM
THREE MILE ISLAND-2
TROJAN
YANKEE NPS
ZION-1
ZION-2
Name
PWR
BWR
BWR
HTGR
X
PWR
PWR
PWR
PWR
BWR
PWR
PWR
PWR
PWR
PWR
Type
2630
2011
0
115
46
2772
1347
24
236
2436
2772
3411
600
3250
3250
900
684
63
42
12
917
456
3
68
849
959
1155
180
1085
1085
Gross
Capacity [MW]
Thermal
Status as of 31 December 2009, 123 reactors (37658 MW) were permanently shut down.
USA
Country
860
641
59
40
12
873
436
3
60
820
880
1095
167
1040
1040
Net
MYAPC
DOMIN
NMC
EXELON
CofPiqua
SMUD
SCE
SNEC
DOE DUQU
LIPA
GPU
PORTGE
YAEC
EXELON
EXELON
Operator
CE
GE
AC
GA
GE
B&W
WH
GE
WH
GE
B&W
WH
WH
WH
WH
NSSS
Supplier
1968-10
1966-5
1959-1
1962-2
1960-1
1969-4
1964-5
1960-1
1954-1
1972-11
1969-11
1970-2
1957-11
1968-12
1968-12
Construction
Start
1972-11
1970-11
1966-7
1967-1
1963-7
1974-10
1967-7
1967-3
1957-12
1986-8
1978-4
1975-12
1960-11
1973-6
1973-12
Grid
Connection
1972-12
1971-3
NA
1967-6
1963-11
1975-4
1968-1
1967-3
1958-5
NA
1978-12
1976-5
1961-7
1973-12
1974-9
Commercial
Operation
1997-8
1998-7
1967-10
1974-11
1966-1
1989-6
1992-11
1972-5
1982-10
1989-5
1979-3
1992-11
1991-10
1998-2
1998-2
Shut Down
54
ITALY
GERMANY
FRANCE
CANADA
ARMENIA
BELGIUM
BULGARIA
Country
AM -18
BE -1
BG -1
BG -2
BG -3
BG -4
CA -1
CA -2
CA -3
FR -2
FR -24
FR -3
FR -4
FR -5
FR -6
FR -7
FR -8
FR -9
DE -10
DE -3
DE -4
DE -501
DE -502
DE -503
DE -504
DE -505
DE -506
DE -6
DE -9
IT -1
IT -2
Code
Reactor
ARMENIA-1
BR-3
KOZLODUY-1
KOZLODUY-2
KOZLODUY-3
KOZLODUY-4
ROLPHTON NPD
DOUGLAS POINT
GENTILLY-1
CHINON-A1
SUPER-PHENIX
CHINON-A2
CHINON-A3
CHOOZ-A (ARDENNES)
EL-4 (MONTS D'ARREE)
ST. LAURENT-A1
ST. LAURENT-A2
BUGEY-1
STADE (KKS)
GUNDREMMINGEN-A (KRB A)
AVR JUELICH (AVR)
RHEINSBERG (KKR)
GREIFSWALD-1 (KGR 1)
GREIFSWALD-2 (KGR 2)
GREIFSWALD-3 (KGR 3)
GREIFSWALD-4 (KGR 4)
GREIFSWALD-5 (KGR 5)
LINGEN (KWL)
WUERGASSEN (KWW)
LATINA
GARIGLIANO
Name
1989-2
1987-6
2002-12
2002-12
2006-12
2006-12
1987-8
1984-5
1977-6
1973-4
1998-12
1985-6
1990-6
1991-10
1985-7
1990-4
1992-5
1994-5
2003-11
1977-1
1988-12
1990-6
1990-2
1990-2
1990-2
1990-7
1989-11
1979-1
1994-8
1987-12
1982-3
Shut
down
Others
2,5
Others
Others
Others
Others
2
2
2
1,2
Others
1,2
1,2
Others
1,2
1,2
1,2
1,2
2
6,8
7
1
3,6,7
3,6,7
3,6
3,5,7
3,6,7
2
2
7,Others
3,4,Others
Shutdown reason
Other
Imdte.dism.
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+SE
Dd+PD+SE
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Imdte.dism.
Dd+PD+SE
Imdte.dism.
Imdte.dism.
Imdte.dism.
Decom.
Strategy
3,4,6
3,4,9
3,4
3,9
3,9
3,9
3
3
3
1,3
9
3,4,6
4,9
9
8
8
8
1
6
4,9
5,6
5,6
3
3
3
4
4
3,6
7
7
4
3
3
Current decom.
Current Fuel
Phase
managemt phase
ANPPJSC
CEN/SCK
E-00707
E-00613
E-00174
E-0008
AECL
AECL
AECL
EDF
NERSA
EDF
EDF
SENA
EDF
EDF
EDF
EDF
E.ON
KGG
xxxx
G 01 KKR
G 01
G 01
G 01
G 01
G 01
KWL GmbH
E.ON
SOGIN
SOGIN
Decom.
Licensee
2014
2018
2019
2019
2015
2027
2025
2020
2014
2025
2036
2036
2036
2036
License
terminated
55
UK
SWEDEN
SPAIN
SLOVAKIA
RUSSIA
LITHUANIA
JAPAN
ITALY
Country
IT -3
IT -4
JP -1
JP -11
JP -2
JP -20
JP -24
KZ -10
LT -46
LT -47
NL -1
RU -3
RU -4
RU -6
RU -8
SK -1
SK -2
SK -3
ES -1
ES -3
SE -1
SE -6
SE -8
GB -10A
GB -10B
GB -12
GB -14
GB -15
GB -1A
GB -1B
GB -1C
GB -1D
Code
Reactor
Name
1990-7
1990-7
1976-3
2009-1
1998-3
2003-3
2009-1
1999-4
2004-12
2009-12
1997-3
1983-1
1988-2
1990-4
1990-8
1977-2
2006-12
2008-12
2006-4
1990-7
1974-6
1999-11
2005-5
2006-12
2006-12
1990-9
1977-3
1994-3
2003-3
2003-3
2003-3
2003-3
Shut
down
7,Others
7,Others
Others
6
2
2
6
2,5
7
7
2,Others
Others
Others
Others
Others
4
7
7
Others
4
2,3
Others
Others
2,8
2,8
Others
Others
Others
2,8
2,8
2,8
2,8
Shutdown reason
Imdte.dism.
Imdte.dism.
Imdte.dism.
Dd+SE
Dd+PD+SE
Dd+SE
Dd+SE
Dd+PD+SE
Imdte.dism.
Imdte.dism.
Dd+SE
Other
Other
Other
Other
Dd+PD+SE
Imdte.dism.
Imdte.dism.
Imdte.dism.
Dd+PD+SE
Dd+SE
Other
Other
Dd+SE
Dd+SE
Imdte.dism.
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Decom.
Strategy
2,3,5,6
2,3,5,6
3,4,9,10
2,5
5
3,5,6
3,5,6
3,5,6
3,5,6
2
2,3,4,9
8
7
3,6
1,5,6,7
3,6,7
1,5
1,5,6,7
1,5,6
1,2,3
1,3
7
3,4
3,4
4
4
5
5
2,3,6
1,2,3,6
3,7
2,5
2
2,3,6
1,2
3
3
Current decom.
Current Fuel
Phase
managemt phase
Decom.
Licensee
2025
2025
2110
2110
2019
2333
2333
2117
2117
2117
2117
2015
2032
2130
2130
2050
2013
2019
2002
2037
2018
2029
2037
License
terminated
56
USA
UK
Country
GB -2A
GB -2B
GB -2C
GB -2D
GB -3A
GB -3B
GB -4A
GB -4B
GB -5
GB -6A
GB -6B
GB -7A
GB -7B
GB -8A
GB -8B
GB -9A
GB -9B
US -001
US -011
US -012
US -013
US -014
US -018
US -077
US -10
US -130
US -133
US -144
US -146
US -155
US -16
US -171
Code
Reactor
CHAPELCROSS 1
CHAPELCROSS 2
CHAPELCROSS 3
CHAPELCROSS 4
BERKELEY 1
BERKELEY 2
BRADWELL 1
BRADWELL 2
WINDSCALE AGR
HUNTERSTON-A1
HUNTERSTON-A2
HINKLEY POINT-A1
HINKLEY POINT-A2
TRAWSFYNYDD 1
TRAWSFYNYDD 2
DUNGENESS-A1
DUNGENESS-A2
SHIPPINGPORT
ELK RIVER
PIQUA
INDIAN POINT-1
BONUS
GE VALLECITOS
HALLAM
DRESDEN-1
PATHFINDER
HUMBOLDT BAY
CVTR
SAXTON
BIG ROCK POINT
ENRICO FERMI-1
PEACH BOTTOM-1
Name
2004-6
2004-6
2004-6
2004-6
1989-3
1988-10
2002-3
2002-3
1981-4
1990-3
1989-12
2000-5
2000-5
1991-2
1991-2
2006-12
2006-12
1982-10
1968-2
1966-1
1974-10
1968-6
1963-12
1964-9
1978-10
1967-10
1976-7
1967-1
1972-5
1997-8
1972-11
1974-11
Shut
down
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
Others
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
3
1
1
5
5,6
1
5
6
1
5
7
Others
2
4
1
Shutdown reason
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+SE
Dd+SE
Dd+SE
Dd+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Dd+PD+SE
Imdte.dism.
Imdte.dism.
in situ disp.
Dd+PD+SE
in situ disp.
Dd+SE
Dd+SE
Dd+SE
Dd+SE
Dd+PD+SE
Dd+SE
Imdte.dism.
Imdte.dism.
Dd+SE
Dd+SE
Decom.
Strategy
9,11
1
3,4,6
11
11
2,3,5,6
2,3,5,6
2,3,5,6
2,3,5,6
3,5,6
3,5,6
3,5,6
3,5,6
2,3,5,6
3,5,6
3,5,6
3,5,6
3,5,6
3,5,6
3,5,6
2,3,5,6
2,3,5,6
5
5
5
5
5
5
Current decom.
Current Fuel
Phase
managemt phase
Decom.
Licensee
2004
2005
1986
2005
2007
1971
1980
1970
2128
2128
2128
2128
2083
2083
2104
2104
2065
2090
2090
2104
2104
2098
2098
2111
2111
1989
1974
License
terminated
57
USA
Country
US -206
US -213
US -245
US -267
US -29
US -295
US -304
US -309
US -312
US -320
US -322
US -344
US -409
Code
Reactor
SAN ONOFRE-1
HADDAM NECK
MILLSTONE-1
FORT ST. VRAIN
YANKEE NPS
ZION-1
ZION-2
MAINE YANKEE
RANCHO SECO-1
THREE MILE ISLAND-2
SHOREHAM
TROJAN
LACROSSE
Name
1992-11
1996-12
1998-7
1989-8
1991-10
1998-2
1998-2
1997-8
1989-6
1979-3
1989-5
1992-11
1987-4
Shut
down
Others
6
6
1
5,7
5,6
5,6
6
5,6
4
7,Others
6
2
Shutdown reason
Dd+PD+SE
Imdte.dism.
Dd+PD+SE
Imdte.dism.
Imdte.dism.
Dd+PD+SE
Dd+PD+SE
Imdte.dism.
Dd+PD+SE
Dd+SE
Imdte.dism.
Dd+PD+SE
Dd+PD+SE
Decom.
Strategy
4,6
1
1
4,11
9,11
11
4,11
4,6
Current decom.
Current Fuel
Phase
managemt phase
Decom.
Licensee
1995
2005
2009
2000
1996
1997
2007
License
terminated
58
Description
Drawing up the Final Decommissioning Plan
Reactor core defuelling
Waste conditioning on site (Only for Decommissioning waste)
Waste shipment off site (Only for Decommissioning waste)
1
2
3
4
5
6
7
8
9
10
11
Description
5
6
7
undefd
Fuel Management
1
2
3
4
5
6
7
8
undefined
Final dismantling
Final survey
Licence terminated (Legal act at the end of the Decommissioning
process)
Imdte.dism.
Dd+SE
Dd+PD+SE
in situ disp.
Description
Decommissioning strategy
Description
Shutdown reason
1
2
3
4
59
80.2
70.5
58.6
77.2
61.8
77.1
86.1
58.6
76.7
75.1
64.8
74.4
83.4
83.5
83.4
Availability
Factor (EAF)
%
Reactors permanently shut down during 2007 to 2009 (5 units) are considered.
13.3
26.2
15.2
18.8
22.0
18.8
10.5
16.4
12.5
16.9
29.7
17.7
11.2
13.4
11.4
81.3
70.7
58.8
78.2
77.1
78.1
86.6
71.7
81.5
76.6
65.0
75.9
84.2
84.3
84.2
4.1
2.2
21.2
2.1
0.1
2.1
2.4
12.8
5.8
6.0
3.6
5.9
3.1
1.4
3.0
Note: 2009 is the latest year for which operating experience data is currently available to the IAEA.
441
TOTAL
18
16
LWGR
GCR
20
FBR
25
12
45
PHWR
81
13
94
BWR
219
266
47
Number
of
Units
PWR
Reactor Category
80.8
61.8
64.8
79.2
74.1
77.9
86.6
68.7
76.8
76.9
68.1
75.7
84.8
84.2
84.7
Operating
Factor (OF)
%
79.5
70.5
58.9
77.2
30.5
77.0
85.8
56.6
75.8
74.6
65.3
74.0
82.8
82.0
82.7
Load
Factor (LF)
%
60
1420
GCR
FBR
Note: 2009 is the latest year for which outage information is currently available to the IAEA.
437
18
ALL REACTORS
11
20
15
LWGR
1712
4065
2004
1732
3005
2071
1340
2752
2110
45
25
PHWR
2202
2193
12
80
1426
1394
2194
92
219
BWR
46
265
In the World
Number of Units
PWR
Reactor Type
72.9
99.5
59.5
82.3
97.0
88.0
78.5
83.7
82.2
68.5
81.6
70.2
67.4
91.5
%
Unplanned
Outages
25.2
0.5
40.1
16.8
1.6
10.9
15.8
15.7
15.7
29.0
18.4
27.6
30.4
7.6
26.5
%
External
Outages
1.9
1.9
0.0
0.4
0.9
1.4
1.1
5.7
0.6
2.1
2.5
0.0
2.2
2.1
0.9
61
63801
47
5973
86
117134
788
427823
Fuel management limitation (including high flux tilt, stretch out or coast-down operation)
Others
TOTAL
Only reactors which have achieved full commercial operation in or before 2009 are counted.
381
166
Fire
100.00
0.18
0.04
539625
8760
843
100.00
1.62
0.16
173833
14787
17438
600
1057
0.35
12.12
10.96
1.09
7.71
63.25
2.74
Environmental conditions (lack of cooling water due to dry weather, cooling water temperature limits, flood, storm, lightning, etc.)
1909
65394
59133
5870
41617
341303
14796
1453
0.09
14.91
9.02
0.21
5.38
67.09
3.08
100.00
8.51
10.03
0.35
0.61
0.84
8.78
0.03
3.44
0.05
67.38
188288
14874
16748
1065
1001
1445
15737
163
9377
144
127734
100.00
7.90
8.89
0.57
0.53
0.77
8.36
0.09
4.98
0.08
67.84
Unplanned
Full Outages
Energy Lost
Time Lost
GW(e).h
%
Hours
%
38578
896
23008
287016
13189
Planned
Full Outages
Energy Lost
Time Lost
GW(e).h
%
Hours
%
62
3788967
TOTAL
Only reactors which have achieved full commercial operation in or before 2009 are counted.
8186
3562
Others
Security and access control and other preventive shutdown due to external threads
Fuel management limitation (including high flux tilt, stretch out or coast-down operation)
100.00
0.22
0.09
0.01
4793733
45594
4208
2077
100.00
0.95
0.09
0.04
0.00
0.00
41
37413
48194
1182
66079
1566
2751
8363
9149
26691
1284329
88630
1079
17898
4040
487
177
1.00
0.99
5.42
4.34
0.63
11.58
73.19
6867
962002
0.00
0.00
47712
47331
259864
207998
30208
554898
3508449
0.19
1.58
2383
182
1.34
9259
75952
100.00
6.90
0.08
1.39
0.31
0.19
0.00
2.91
3.75
0.09
5.15
0.12
0.21
0.65
0.71
2.08
0.53
74.90
1581838
104686
1731
17347
4718
2311
31
39494
50292
1277
76004
1873
2880
16928
15077
37677
10186
1199327
100.00
6.62
0.11
1.10
0.30
0.15
0.00
2.50
3.18
0.08
4.80
0.12
0.18
1.07
0.95
2.38
0.64
75.82
Unplanned
Full Outages
Time Lost
Energy Lost
GW(e).h
%
Hours
%
Fire
50755
0.77
29174
3.03
5.24
114985
198608
8.79
77.98
0.49
333083
2954483
0.19
1.83
18748
7283
69429
Planned
Full Outages
Energy Lost
Time Lost
GW(e).h
%
Hours
%
63
AM
AR
BE
BG
BR
CA
CH
CN
CZ
DE
ES
FI
FR
GB
HU
IN
IR
IT
JP
KR
KZ
LT
MX
NL
PK
RO
RU
SE
SI
SK
Country
Code
ARMENIA
ARGENTINA
BELGIUM
BULGARIA
BRAZIL
CANADA
SWITZERLAND
CHINA
CZECH REPUBLIC
GERMANY
SPAIN
FINLAND
FRANCE
UNITED KINGDOM
HUNGARY
INDIA
IRAN, ISLAMIC REPUBLIC OF
ITALY
JAPAN
KOREA, REPUBLIC OF
KAZAKHSTAN
LITHUANIA, REPUBLIC OF
MEXICO
NETHERLANDS
PAKISTAN
ROMANIA
RUSSIAN FEDERATION
SWEDEN
SLOVENIA
SLOVAK REPUBLIC
Full Name
2
1
2
2
31
10
1
4
54
20
1
2
7
2
2
18
5
11
6
17
8
4
59
19
4
18
Operational
1
2
4
5
11
26
19
2
5
3
1
4
1
6
5
1
1
1
20
11
2
38
Planned
64
TURKEY
UKRAINE
UNITED STATES OF AMERICA
SOUTH AFRICA
Note: The total includes the following data from Taiwan, China:
TOTAL
TR
UA
US
ZA
Country
Code
Full Name
437
15
104
2
Operational
55
2
1
5
123
4
28
61
Planned
65
TOTAL
BWR
FBR
GCR
HTGR
HWGCR
HWLWR
LWGR
PHWR
PWR
SGHWR
X
Type
Code
Full Name
55
1
3
46
15
45
265
437
3
2
123
23
6
34
4
3
2
9
5
34
1
2
92
2
18
Operational
Planned
61
51
66
AEC/NPPD
ALP
AMERGENE
ANAV
ANPPJSC
AVR
AZPSCO
BE
BHAVINI
BKAB
BKW
BRUCEPOW
BV GKN
CCNPP
CEA/EDF
CEN/SCK
CEZ
CFE
CHUBU
CHUGOKU
CNAT
CofPiqua
COGEMA
CONSENEC
CPC
CVPA
CYAPC
DETED
DOE DUQU
DOE/PRWR
Operator
Code
Full Name
6
2
3
2
3
3
1
1
6
3
15
2
4
3
1
Operational
1
2
1
1
1
1
1
1
1
2
1
1
67
DOMENGY
DOMIN
DPC
DUKE
E.ON
EDF
ELECTRAB
ELETRONU
EMO
EnBW
ENERGYNW
EnKK
ENTERGY
ENTGARKS
ENTGS
EPDC
EPZ
ESKOM
EWN
EXELON
FENOC
FKA
FORTUMPH
FPL
FPLDUANE
FQNP
GE
GNPJVC
GPU
HDR
HEPCO
Operator
Code
Full Name
14
4
3
2
5
1
1
2
1
4
8
1
1
7
5
58
7
2
1
2
Operational
1
1
6
4
1
8
1
1
68
HIFRENSA
HKG
HOKURIKU
HONGYANH
HQ
ID
IMPCO
INPP
JAEA
JAPCO
JAVYS
JNPC
KBG
KEPCO
KGB
KGECO
KGG
KHNP
KKB
KKG
KKK
KKL
KKN
KLE
KOZNPP
KWG
KWL
KYUSHU
LANPC
LDNPC
LHNPC
Operator
Code
Full Name
6
2
1
2
1
1
2
20
1
1
1
1
11
1
1
2
Operational
2
4
2
2
1
3
1
1
69
LIPA
MAEC-KAZ
MEL
MSM
MTE
MYAPC
NASA
NBEPC
NDNPC
NEK
NMC
NMPNSLLC
NNEGC
NOK
NORTHERN
NPCIL
NPPD
NPPDCO
NPQJVC
NUCLENOR
OH
OKG
OPG
OPPD
PAEC
PAKS Zrt
PE
PGE
PORTGE
PP&L
PROGENGC
Operator
Code
Full Name
2
3
3
10
1
2
4
2
1
1
1
2
15
2
2
18
1
2
1
Operational
1
2
1
1
1
1
1
22
5
4
1
70
TOHOKU
TPC
TQNPC
TVA
TVO
PROGRESS
PSCC
PSEG
PSEGPOWR
QNPC
RAB
RCPA
REA
RWE
SCE
SCEG
SE,plc
SENA
SHIKOKU
SMNPC
SMUD
SNEC
SNN
SNPC
SOGIN
SOUTH
STP
TEAS
TEPCO
TNPC
Operator
Code
Full Name
4
6
2
6
2
17
4
2
31
2
2
1
4
1
2
1
4
Operational
1
1
1
1
1
4
71
TOTAL
TXU
UFG
UKAEA
VAK
VEPCO
WEP
YAEC
YJNPC
not specified
Operator
Code
Full Name
437
4
2
Operational
55
2
5
123
1
4
1
61
4
28
Planned
72
A/F/W
ABBATOM
AC
ACECOWEN
ACLF
AECL
AECL/DAE
AECL/DHI
AEE
AEG
AEG,GE
AEG,KWU
AMN/GETS
APC
AREVA
ASE
ASEASTAL
ASPALDO
AtEE
B&W
BBC
BBK
BBR
CE
CEA
CGE
CNCLNEY
CNNC
DFEC
NSSS Supplier
Code
Full Name
1
1
4
14
7
1
4
1
8
1
3
8
Operational
3
14
3
5
1
1
1
1
1
1
1
6
3
6
1
1
2
1
2
1
2
3
10
Planned
73
DHICKAEC
DHICKOPC
EE/B&W/T
EL/WEST
FAEA
FRAM
FRAMACEC
GA
GAAA
GE
GE,AEG
GE/GETSC
GE/T
GEC
GETSCO
GNEPRWRA
GTM
HITACHI
HRB
IA
ICL/FE
IZ
KWU
LEVIVIER
MAEC-KAZ
MAEP
MHI
MSM
NEI.P
NNC
NPC
NSSS Supplier
Code
Full Name
2
2
6
20
2
20
10
1
2
2
2
47
1
64
2
2
6
2
Operational
1
2
1
2
1
1
1
1
1
1
2
1
11
1
4
1
5
3
74
TOTAL
NPCIL
OH/AECL
PAA
PAIP
PPC
RDM
ROSATOM
S/KWU
SACM
SIEM,KWU
SIEMENS
SKODA
T/H/F/M
TBD
TNPG
TOSHIBA
UEC
UKAEA
WH
WH/MHI
not specified
NSSS Supplier
Code
Full Name
1
2
1
10
437
71
1
55
2
2
1
31
1
6
15
123
8
2
1
10
10
2
2
1
1
14
14
4
11
1
Operational
61
38
Planned
300
Number of Reactors
200
150
92
100
83.6
0.7
15
10.2
18
22.6
45
50
9.0
250
244.7
265
0
PWR
BWR
GCR
PHWR
LWGR
FBR
Reactor Type
Figure 1. Nuclear reactors by type and net electrical power
(as of 31 Dec. 2009)
75
50
46
Number of Reactors
43.72
40
30
20
1.27
0.92
3
1.1
3.93
10
0
PWR
BWR
PHWR
LWGR
Reactor Type
Figure 2. Reactors under construction by type and
net electrical power
(as of 31 Dec. 2009)
76
FBR
77
0%
7.0%
4.8%
4.8%
3.7%
2.9%
2.7%
2.2%
1.9%
20%
20.6%
20.2%
17.9%
17.8%
17.5%
14.8%
28.9%
26.1%
40%
39.5%
37.8%
37.4%
35.9%
34.8%
33.8%
32.9%
45.0%
43.0%
53.5%
51.6%
48.6%
Note: The nuclear share of electricity supplied in Taiwan, China was 20.6% of the total.
LITHUANIA
FRANCE
SLOVAKIA
BELGIUM
UKRAINE
ARMENIA
HUNGARY
SWITZERLA
SLOVENIA
SWEDEN
BULGARIA
KOREA
CZECH REP.
FINLAND
JAPAN
GERMANY
ROMANIA
USA
UK
RUSSIA
SPAIN
CANADA
ARGENTINA
SOUTH
MEXICO
NETHERLA
BRAZIL
PAKISTAN
INDIA
CHINA
60%
80%
76.2%
75.2%
100%
78
Number of Reactors
23
29
64
71
80
80
Construction Time
2009
2006-2008
20
20
2001-2005
1996-2000
1991-1995
1986-1990
74
85
86
95
99
100
1981-1985
1976-1980
103
123
131
140
120
60
40
79
Number of Reactors
10
15
20
25
30
35
10
11
12
13
14
15
16
17
18
19
21
22
23
24
25
33
26
21
27
18
20
11
10
14
21
24
32
28
22
29
19
30
31
13
32
14
33
16
34
11
35
22
36
15
37
10
38
12
39
40
41
42
Number of Reactors
Figure 6. Annual construction starts and connections to the Grid (1954 2009)
10
20
30
40
50
1
1
8
0
1
5
13
3
6
11
4
7
5
8
8
9
9
9
15
25
11
32
6
16
10
36
6
17
16
31
16
31
20
36
26
37
15
44
19
25
18
20
23
28
8
20
21
16
23
19
19
16
23
10
33
20
33
27
13
22
14
12
5
2
10
4
3
Construction Starts
6
4
9
5
5
1
6
3
3
5
4
4
4
6
6
Grid Connections
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
80
3
6
6
1
2
2
5
3
4
4
8
10
11
No. 22
BELGIUM
Jean de Lannoy, avenue du Roi 202, B-1190 Brussels
Telephone: +32 2 538 43 08 Fax: +32 2 538 08 41
Email: jean.de.lannoy@infoboard.be Web site: http://www.jean-de-lannoy.be
CANADA
Bernan Associates, 4501 Forbes Blvd, Suite 200, Lanham, MD 20706-4346, USA
Telephone: 1-800-865-3457 Fax: 1-800-865-3450
Email: customercare@bernan.com Web site: http://www.bernan.com
Renouf Publishing Company Ltd., 1-5369 Canotek Rd., Ottawa, Ontario, K1J 9J3
Telephone: +613 745 2665 Fax: +613 745 7660
Email: order.dept@renoufbooks.com Web site: http://www.renoufbooks.com
CHINA
IAEA Publications in Chinese: China Nuclear Energy Industry Corporation, Translation Section,
P.O. Box 2103, Beijing
CZECH REPUBLIC
Suweco CZ, S.R.O., Klecakova 347, 180 21 Praha 9
Telephone: +420 26603 5364 Fax: +420 28482 1646
Email: nakup@suweco.cz Web site: http://www.suweco.cz
FINLAND
Akateeminen Kirjakauppa, PO BOX 128 (Keskuskatu 1), FIN-00101 Helsinki
Telephone: +358 9 121 41 Fax: +358 9 121 4450
Email: akatilaus@akateeminen.com Web site: http://www.akateeminen.com
FRANCE
Form-Edit, 5, rue Janssen, P.O. Box 25, F-75921 Paris Cedex 19
Telephone: +33 1 42 01 49 49 Fax: +33 1 42 01 90 90
Email: formedit@formedit.fr Web site: http://www. formedit.fr
Lavoisier SAS, 145 rue de Provigny, 94236 Cachan Cedex
Telephone: + 33 1 47 40 67 02 Fax +33 1 47 40 67 02
Email: romuald.verrier@lavoisier.fr Web site: http://www.lavoisier.fr
GERMANY
UNO-Verlag, Vertriebs- und Verlags GmbH, Am Hofgarten 10, D-53113 Bonn
Telephone: + 49 228 94 90 20 Fax: +49 228 94 90 20 or +49 228 94 90 222
Email: bestellung@uno-verlag.de Web site: http://www.uno-verlag.de
HUNGARY
Librotrade Ltd., Book Import, P.O. Box 126, H-1656 Budapest
Telephone: +36 1 257 7777 Fax: +36 1 257 7472 Email: books@librotrade.hu
INDIA
Allied Publishers Group, 1st Floor, Dubash House, 15, J. N. Heredia Marg, Ballard Estate,
Mumbai 400 001,
Telephone: +91 22 22617926/27 Fax: +91 22 22617928
Email: alliedpl@vsnl.com Web site: http://www.alliedpublishers.com
Bookwell, 2/72, Nirankari Colony, Delhi 110009
Telephone: +91 11 23268786, +91 11 23257264 Fax: +91 11 23281315
Email: bookwell@vsnl.net
ITALY
Libreria Scientifica Dott. Lucio di Biasio AEIOU, Via Coronelli 6, I-20146 Milan
Telephone: +39 02 48 95 45 52 or 48 95 45 62 Fax: +39 02 48 95 45 48
Email: info@libreriaaeiou.eu Website: www.libreriaaeiou.eu
JAPAN
Maruzen Company, Ltd., 13-6 Nihonbashi, 3 chome, Chuo-ku, Tokyo 103-0027
Telephone: +81 3 3275 8582 Fax: +81 3 3275 9072
Email: journal@maruzen.co.jp Web site: http://www.maruzen.co.jp
REPUBLIC OF KOREA
KINS Inc., Information Business Dept. Samho Bldg. 2nd Floor, 275-1 Yang Jae-dong SeoCho-G,
Seoul 137-130
Telephone: +02 589 1740 Fax: +02 589 1746 Web site: http://www.kins.re.kr
NETHERLANDS
De Lindeboom Internationale Publicaties B.V., M.A. de Ruyterstraat 20A, NL-7482 BZ
Haaksbergen
Telephone: +31 (0) 53 5740004 Fax: +31 (0) 53 5729296
Email: books@delindeboom.com Web site: http://www.delindeboom.com
Martinus Nijhoff International, Koraalrood 50, P.O. Box 1853, 2700 CZ Zoetermeer
Telephone: +31 793 684 400 Fax: +31 793 615 698
Email: info@nijhoff.nl Web site: http://www.nijhoff.nl
Swets and Zeitlinger b.v., P.O. Box 830, 2160 SZ Lisse
Telephone: +31 252 435 111 Fax: +31 252 415 888
Email: infoho@swets.nl Web site: http://www.swets.nl
NEW ZEALAND
DA Information Services, 648 Whitehorse Road, MITCHAM 3132, Australia
Telephone: +61 3 9210 7777 Fax: +61 3 9210 7788
Email: service@dadirect.com.au Web site: http://www.dadirect.com.au
SLOVENIA
Cankarjeva Zalozba d.d., Kopitarjeva 2, SI-1512 Ljubljana
Telephone: +386 1 432 31 44 Fax: +386 1 230 14 35
Email: import.books@cankarjeva-z.si Web site: http://www.cankarjeva-z.si/uvoz
SPAIN
Daz de Santos, S.A., c/ Juan Bravo, 3A, E-28006 Madrid
Telephone: +34 91 781 94 80 Fax: +34 91 575 55 63
Email: compras@diazdesantos.es, carmela@diazdesantos.es, barcelona@diazdesantos.es,
julio@diazdesantos.es
Web site: http://www.diazdesantos.es
UNITED KINGDOM
The Stationery Office Ltd, International Sales Agency, PO Box 29, Norwich, NR3 1 GN
Telephone (orders): +44 870 600 5552 (enquiries): +44 207 873 8372 Fax: +44 207 873 8203
Email (orders): book.orders@tso.co.uk (enquiries): book.enquiries@tso.co.uk Web site: http://
www.tso.co.uk
On-line orders
DELTA Int. Book Wholesalers Ltd., 39 Alexandra Road, Addlestone, Surrey, KT15 2PQ
Email: info@profbooks.com Web site: http://www.profbooks.com
Books on the Environment
Earthprint Ltd., P.O. Box 119, Stevenage SG1 4TP
Telephone: +44 1438748111 Fax: +44 1438748844
Email: orders@earthprint.com Web site: http://www.earthprint.com
UNITED NATIONS
Dept. I004, Room DC2-0853, First Avenue at 46th Street, New York, N.Y. 10017, USA
(UN) Telephone: +800 253-9646 or +212 963-8302 Fax: +212 963-3489
Email: publications@un.org Web site: http://www.un.org
Orders and requests for information may also be addressed directly to:
Marketing and Sales Unit, International Atomic Energy Agency
Vienna International Centre, PO Box 100, 1400 Vienna, Austria
Telephone: +43 1 2600 22529 (or 22530) Fax: +43 1 2600 29302
Email: sales.publications@iaea.org Web site: http://www.iaea.org/books
10-20781
I N T E R N AT I O N A L AT O M I C E N E R G Y A G E N C Y
VIENNA
ISBN 978-92-0-105610-8
ISSN 1011-2642