Technical data
Operating medium: Solenoid valve for filtered, lubricated1) or non-lubricated air Actuation: Solenoid operated, indirectly controlled Flow direction: Fixed Mounting position: Optional, preferably with solenoid on top Nominal size: 4 and 6 Port size: G 1/8, G 1/4, 1/4 NPT Electrical connection: Connector interface to DIN 43650 form A and B Operating pressure: 2 to 8 bar Temperature: -10* C to 50 C
*With minus temperatures, use conditioned dry air. If installed in the open protect all connections against the penetration of moisture!
Ordering example
3/2 directional control valve, connection G 1/4, solenoid 24 V DC, protection class IP65 Part No.: 8010777.3037.024.00
3/2
4/2
Current draw: < 2 W standard Material: Housing: Aluminium Pilot flange: Plastic Seat seal: NBR (Perbunan)
5/2
1) Oil recommendation: Shell Hydrol DO 32, Esso Febis (as of July 1992) or comparable oils with DVI values < 8 (DIN 53521) and ISO viscosity class 32-46 (DIN 51519).
8/99
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/** 5.4.302.01
General information
Symbol
2 12 10 3
Nominal size
14 13 24 14 13 2 4 14 315 4 2 14 513
12
2622077
G 1/8
Flange
0,7
0,3
M02
12
2622177
G 1/8
Flange
0,7
0,3
M03
2623077
12
2 2 2
8 8 8
2623078
12
2623177
* When ordering please indicate solenoid, voltage and current type (frequency). Port 3 not throttleable.
Solenoid parameters
Type Current draw 24 V DC (W) 1,7 1,7 Protection class 230 V AC (VA) 5,6/4,3 5,6/4,3 Temperature Fluid max. (C) Weight Ambience (C) -15 to +50 -15 to +50 (kg) 0,06 0,08 M06 M06 SB01 SB01 Dimensional drawing Circuit diagram
3050 3051
3036 3037
1,6 1,6
4,55/3,5 4,55/3,5
IP 00 without conn. +50 IP 65 with connector+50 DIN 43650 form A EEx m II T6 with cable 3 m EEx m II T6 with cable 3 m +80
0,09 0,12
M07 M07
SB01 SB01
3042
3,3
-15 to +50
0,13
M08
SB01
3043
3,3
+80
-15 to +50
0,13
M08
SB08
Standard voltages 24 V DC, 230 V AC. Other voltages on request. Note: When valves of nominal size 4 are used with a 30 mm solenoid, a spacer plate Part No. 0540109 is required.
N/** 5.4.302.02
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
08/99
2 4 12 315 a
BA b S PR
4 2 14 513 12 a
BA b S PR
Mounting accessories
Designation Flange plate Yoke Spacer plate Silencer Throttle check valve plate Quick exhaust plate with throttle Part No. 0559857 0540593 0540109 0014500 0014600 4040238 4050218 Application Direct mounting on pneumatic linear actuators with NAMUR ribbing and for wall mounting, depending on piping position In conjunction with flange plate for mounting on pneumatic linear actuators with NAMUR pillar (round) Direct mounting on pneumatic rotary actuators, e.g. when using a solenoid with a terminal box Port size G 1/8, back pressure max. = 6 bar Port size G 1/4, back pressure max. = 6 bar Exhaust air flow control Quick exhaust plate with integrated exhaust air recirculation; can be retrofitted with throttle to form throttle check valve plate Weight (kg) 0.50 7502242 0.10 0.25 0.01 0.39 0.35 7502242 7501080 7503042 7502144 See data sheet
Dimensional drawings
3/2 directional control valve M01
Manual override
14
19,5
G1/4
1 2 3
12 12
24
15,5
5,5 x 3 deep
23
4
M5 5 7 30 5
15,5 19,5 32 55
08/99
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
126
N/** 5.4.302.03
19,5
116,5
15,5
G1/8
2 1 3
32 40 12 12
9,5
5,5 x 3 deep
32,5
4
M5 15,5
20,5
19,5
G1/8
2 1 3
96,5 12 12
180,5
9,5
5,5 x 3 deep
4
M5
84,5
12
32 40
N/** 5.4.302.04
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
08/99
Manual override
G1/4
3 2 1
12 12
24
24
5,5 x 3 deep
4
M5 35 5 7 30 5
5
15,5 19,5 32 55
G1/4
3 2
12 223 5 7 30 5 111,5 12
24
1
24
Manual override
14
15,5 19,5
12
32 55
08/99
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
M5
5,5 x 3 deep
143,5
N/** 5.4.302.05
M07
36
29,5
29,5
11 65 12
15 72 12
22
30
M08
36
29,5
15 68
30
Circuit diagrams
SB01 SB08
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable.
N/** 5.4.302.06
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
08/99
08/99
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/** 5.4.302.07
N/** 5.4.302.08
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
08/99